HomeMy WebLinkAboutENGINEER BOILER PLATE - 23-00327 - Whole Child Family Daycare - Stairwell & WindowsWINDOW WELL DETAIL
CASEMENT WINDOW 20' MIN
FULLY OPEN��
BASEMENT WALL LADDER REQUIRED
IF WELL IS OVER
FRAME
WINDOW WELL
26' X 44' OPENING
36' MIN
PATENT ON FRAME
4' X 4' X 1/4' WELDED STEEL FRAME.
INSERT FRAME INT❑ CONCRETE FROM
OUTSIDE AND SEAL FLANGES
WITH RESILIENT SEALER.
ATTACH TO CONCRETE WITH
1/4' CONCRETE FASTENERS.
4'
36• MIN END VIEW OF iFRAME
CASEMENT WINDOW,
OR EQUIVALENT
ORIGINAL WINDOW
n
I
� I
EXTENDED CUTOUT
24'
WHEN NECESSARY
USE MULTIPLE SETS OF 4' LONG STEEL SHIMS
TOTALING 12' IN WIDTH BETWEEN FRAME AND
ORIGINAL WINDOW FRAME, OR FRAME
AND CONCRETE, TO FORCE BOTTOM
OF NEW FRAME AGAINST BOTTOM OF
CONCRETE CUTOUT, OR BETWEEN BOTTOM
OF FRAME AND CONCRETE.
20' MIN
5.7 SQ FT
MIN
29.25'
I
47.25' 55.25'
1I
I— 37.25' —I
as MAx FRAME FACE VIEW OF FRAME
FLOOR EGRESS
WINDOW DETAIL KEEP TOP AND SI➢ES OF ❑RIGINAL
WINDOW FRAME IN PLACE. D❑ NOT
THIS DESIGN MEETS
THE FOLLOWING REQUIREMENTS CHANGE OR REMOVE ANY
1. MEETS 2018 IRC
FOUNDATION WALL OR STRUCTURAL
2.136 mph AS➢ EXP
C WIN➢
FRAMING ABOVE WINDOW
3. 3 sec. GUSTS
4, ROOF SNOW LOAD
30 lb./sq ft
5. GROUND SNOW LOAD 42.9 lb./sq ft
6. SEISMIC DESIGN CATEGORY
B
BASEMENT EGRESS WINDOW DETAILS
SIZE
OWNER
DWG NO-
REV
A
xxx
AS-001
0
SCALE NONE
SHEET 1
OF I