Loading...
HomeMy WebLinkAboutREVISED SITE PLAN - 21-00247 - 1133 Greenside Loop - New SFRD,2 631 R„ / r SVOQE DSO'11I N \\ �/ ' CONCRETE DRIVE \ \ \ 9 \ \ \ \ \ I ' / / / , / I ' , / / / 20'-0" w SETBACK ' I / / / MAIN F.F.=100'-0" rI�s o 0" M �a / rn % m / f/ / a �I N / ' � f / / / U / f N � , I ' co to f 26'-0" I 50.07' PROPEF TY LINE 24'-0 314" 11. 1 , 4 25� /�ePG'h / / , / / , / v V GARAGE T.O.S.=98'-6" a NOTES: 1. DRIVEWAY SHALL BE GRADED SUCH THAT WATER DRAINING OFF THE DRIVE DOES NOT FLOW ONTO THE ROAD AND IS DIVERTED INTO A ROADSIDE DITCH OR GUTTER. 2. MIN. DRIVEWAY FLARES TO BE 2'-0" AS REQ'D BY CODE. 3. HOUSE DRAINAGE FINAL GRADES TO BE MIN. 6" OF FALL FOR FIRST 10' FROM HOME. 4. LOT IS TO BE GRADED AND LANDSCAPED IN A MANNER THAT WILL PREVENT WATER RUNOFF FROM ADVERSELY AFFECTING ADJOINING PROPERTY LINES. 5. PROVIDE METALLIC WATER SERVICE & CONCRETE ENCASED ELECTRODE PER 2017 NEC. 6. ALL CONSTRUCTION TO COMPLY WI THE 2018 INTERNATIONAL BUILDING CODE. 7. STORM DRAINAGE TO FLOW TO APPROVED STORM DRAIN SYSTEM. 8. PROVIDE ROAD BASE RAMP TO PROTECT PAVED ROAD, CURB AND SIDEWALK AS REQUIRED. 9. PROVIDE 1"WATER LINE TO HOUSE. 10. DUST, MUD AND EROSION SHALL BE CONTROLLED BY WHATEVER MEANS NECESSARY, AND THE ROADWAY SHALL BE KEPT FREE OF MUD AND DEBRIS AT ALL TIMES. 11. BUILDER/OWNER SHALL REPLACE ANY EXISTING SIDEWALK OR CURB & GUTTER ALONG THE FRONTAGE OF THIS PROJECT THAT IS FOUND TO BE DEFECTIVE, AS DIRECTED BY THE CITY INSPECTOR. 12. SETBACKS ARE DETERMINED BY LOCAL ZONING ORDINANCES. 13. PROPERTY LINES AND SETBACKS VARY IN RELATIONSHIP TO THE STREET, SIDEWALK, ETC. 14. VERIFY WITH BUILDING DEPT. AND I OR SURVEYOR FOR ACCURATE PLACEMENT OF STRUCTURE. 15. SOME JURISDICTIONS REQUIRE MIN. DISTANCES BETWEEN ADJACENT STRUCTURES WHICH WILL OVERRIDE A SETBACK. VERIFY WI LOCAL BUILDING I ZONING DEP. 16. VERIFY ALL HEIGHT RESTRICTIONS W/ LOCAL BUILDING 1 ZONING DEP. CRAIG WALL DESIGN 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 EACH SUB -CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB -CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. W U Z (/) W WT C Q < Q r._n �./ / �C'3 O W W m�� CC 0D � CO W 0oocc J W � z .. C7 � �c/) .0 L Q. ( revisions: Project number Date MARCH 26, 2021 Drawn by CVVD Engineered by NIA SITE PLAN cl no