HomeMy WebLinkAboutAPPROVED PLANS - 21-00247 - 1133 Greenside Loop - New SFRAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Alan Parkinson Alan.Parkinson@rexburg.org 208-372-2165 Description : 1133 Greenside Loop - New SFR Address : Record Type : New Single Family Residence Document Filename : FINAL Sommer_4.9.21.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 21-00247 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments C1.0 Stamp Larry Beesley : Building Open 1 A1.0 Stamp Larry Beesley : Building Open 2 A1.0 Free text Larry Beesley : Building Open 2 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. A1.0 Free text Larry Beesley : Building Open 2 Minimum Frost Depth Ground Surface to Bottom of Footing 36" A1.1 Stamp Larry Beesley : Building Open 3 A1.1 Free text Larry Beesley : Building Open 3 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. A1.1 Free text Larry Beesley : Building Open 3 Street Number Displayed on House A2.0 Stamp Larry Beesley : Building Open 4 A2.0 Free text Larry Beesley : Building Open 4 Tar house foundation. A3.0 Stamp Larry Beesley : Building Open 5 A3.0 Free text Larry Beesley : Building Open 5 20 min doors New Single Family Residence Follow the red lines and specked information. Also the house is being built using the 2018 IRC code. Approval of plans does not constitute approval of variance from code Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A3.0 Line Larry Beesley : Building Open 5 A3.0 Line Larry Beesley : Building Open 5 A3.0 Free text Larry Beesley : Building Open 5 SD CO A3.0 Free text Larry Beesley : Building Open 5 SD A3.0 Free text Larry Beesley : Building Open 5 SD A3.0 Free text Larry Beesley : Building Open 5 SD A4.0 Stamp Larry Beesley : Building Open 6 A4.1 Stamp Larry Beesley : Building Open 7 A4.1 Free text Larry Beesley : Building Open 7 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) A5.0 Stamp Larry Beesley : Building Open 8 A5.0 Rectangle Larry Beesley : Building Open 8 A5.0 Free text Larry Beesley : Building Open 8 also on 4' walls A5.0 Free text Larry Beesley : Building Open 8 ? 8" x 20" A5.1 Stamp Larry Beesley : Building Open 9 E1.0 - MAIN FLOOR ELECTRICAL PLAN Stamp Larry Beesley : Building Open 10 C1.0 Polygon Alan Parkinson : P&Z Open 1 0.00 sq in Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) NORTH SCALE 1"=10' SITE PLAN 2 0 4.2 1' P R O P E R T Y LI N E 50.07' PROPERTY LINE 146.19' PROPERTY LINE 1 8 0 .1 1 ' P R O P E R T Y L I N E 6 4 . 1 8 ' P R O P E R T Y L I N E GARAGE T.O.S.=98'-6" MAIN F.F.=100'-0" SETBACK PER CI TY CODE 4. 02. 080 13' -0" SE T B A C K 20 ' - 0 " SETBACK 20'-0" S E T B A C K P E R C I T Y C O D E 4 . 0 2 . 0 8 0 1 3 '- 0 " SETBACK 25'-0" CONCRETE DRIVE S L O P E 50' -1 1/ 8" 28' -7 3/ 4" 100'-2 1/8" 119'-10 5/8" 18' -2 3/ 4" 14' -4 3/ 4" 25'-5 1/2" 49'-2 3/8" 33' -9 1/ 8"54'-6 3/8" 48'-6 1/2" 97'-7 3/4" 24'-0 3/4"26'-0" 104'-2 1/4" 75'-10" 24'-2 1/4" 29'-9 7/8" 46'-1 1/2" 39'-6 3/8" 22'-0 3/4" 42'-6 3/4" pr o j e c t : revisions: Project number Date Drawn by Engineered by 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. C1.0 MARCH 26, 2021 SO M M E R R E S I D E N C E LO T 4 B L O C K 1 PI N E B R O O K E S T A T E S RE X B U R G , I D CWD N/A SITE PLAN NOTES: 1. DRIVEWAY SHALL BE GRADED SUCH THAT WATER DRAINING OFF THE DRIVE DOES NOT FLOW ONTO THE ROAD AND IS DIVERTED INTO A ROADSIDE DITCH OR GUTTER. 2. MIN. DRIVEWAY FLARES TO BE 2'-0" AS REQ'D BY CODE. 3. HOUSE DRAINAGE FINAL GRADES TO BE MIN. 6" OF FALL FOR FIRST 10' FROM HOME. 4. LOT IS TO BE GRADED AND LANDSCAPED IN A MANNER THAT WILL PREVENT WATER RUNOFF FROM ADVERSELY AFFECTING ADJOINING PROPERTY LINES. 5. PROVIDE METALLIC WATER SERVICE & CONCRETE ENCASED ELECTRODE PER 2017 NEC. 6. ALL CONSTRUCTION TO COMPLY W/ THE 2018 INTERNATIONAL BUILDING CODE. 7. STORM DRAINAGE TO FLOW TO APPROVED STORM DRAIN SYSTEM. 8. PROVIDE ROAD BASE RAMP TO PROTECT PAVED ROAD, CURB AND SIDEWALK AS REQUIRED. 9. PROVIDE 1" WATER LINE TO HOUSE. 10. DUST, MUD AND EROSION SHALL BE CONTROLLED BY WHATEVER MEANS NECESSARY, AND THE ROADWAY SHALL BE KEPT FREE OF MUD AND DEBRIS AT ALL TIMES. 11. BUILDER/OWNER SHALL REPLACE ANY EXISTING SIDEWALK OR CURB & GUTTER ALONG THE FRONTAGE OF THIS PROJECT THAT IS FOUND TO BE DEFECTIVE, AS DIRECTED BY THE CITY INSPECTOR. 12. SETBACKS ARE DETERMINED BY LOCAL ZONING ORDINANCES. 13. PROPERTY LINES AND SETBACKS VARY IN RELATIONSHIP TO THE STREET, SIDEWALK, ETC. 14. VERIFY WITH BUILDING DEPT. AND / OR SURVEYOR FOR ACCURATE PLACEMENT OF STRUCTURE. 15. SOME JURISDICTIONS REQUIRE MIN. DISTANCES BETWEEN ADJACENT STRUCTURES WHICH WILL OVERRIDE A SETBACK. VERIFY W/ LOCAL BUILDING / ZONING DEP. 16. VERIFY ALL HEIGHT RESTRICTIONS W/ LOCAL BUILDING / ZONING DEP. MAIN F.F. 100'-0" MAIN F.F. 100'-0" MAIN TOP PLATE 109'-0" MAIN TOP PLATE 109'-0" GARAGE T.O.S. 98'-6" GARAGE T.O.S. 98'-6" A A5.1 A A5.1 SCALE 1/4"=1'-0" FRONT ELEVATION 12 8 12 8 12 8 6' - 8 " 6' - 8 " ARCHITECTURAL SHINGLES BRICK BRICK BRICK 25 ' - 9 1 / 4 " 12 8 12 8 MAIN F.F. 100'-0" MAIN F.F. 100'-0" MAIN TOP PLATE 109'-0" MAIN TOP PLATE 109'-0" FAMILY ROOM T.P. 111'-0" GARAGE T.O.S. 98'-6" 12 8 12 8 SCALE 1/4"=1'-0" LEFT ELEVATION 6' - 8 " ARCHITECTURAL SHINGLES BRICK BRICKBRICK BRICK PROVIDE 1 SQ. FT. OF ATTIC SPACE VENTILATION FOR EVERY 150 SQ. FT. OF ATTIC SPACE 12 8 12 8 pr o j e c t : revisions: Project number Date Drawn by Engineered by 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. A1.0 MARCH 26, 2021 SO M M E R R E S I D E N C E LO T 4 B L O C K 1 PI N E B R O O K E S T A T E S RE X B U R G , I D CWD N/A EXTERIOR ELEVATIONS NOTES: 1. EXTERIOR WALL FINISHES MUST BE LISTED, LABELED, AND INSTALLED AS PER MANUFACTURER'S INSTALLATION INSTRUCTION GUIDES. 2. INSPECTION OF THE WEATHER-RESISTIVE BARRIER AND FLASHING IN ORDER TO PREVENT WATER FROM ENTERING THE WEATHER-RESISTANT EXTERIOR WALL ENVELOPE IS REQUIRED. R109.1.5 3. ALL FOOTINGS SHALL BEAR 30" OR 36" MIN. BELOW FINISH GRADE (VERIFY DEPTH WITH LOCAL CODES), BUT NO LESS THAN 12" BELOW NATURAL GRADE. 4. HOUSE DRAINAGE FINAL GRADES TO BE MIN. 6" OF FALL FOR FIRST 10' FROM HOME. Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Minimum Frost Depth Ground Surface to Bottom of Footing 36" MAIN F.F. 100'-0" MAIN F.F. 100'-0" MAIN TOP PLATE 109'-0" MAIN TOP PLATE 109'-0" FAMILY ROOM T.P. 111'-0" FAMILY ROOM T.P. 111'-0" GARAGE T.O.S. 98'-6" A A5.1 A A5.1 12 8 12 8 12 8 SCALE 1/4"=1'-0" REAR ELEVATION 6' - 8 " 6' - 8 " 1' - 0 " 2' - 0 " ARCHITECTURAL SHINGLES BRICK PROVIDE 1 SQ. FT. OF ATTIC SPACE VENTILATION FOR EVERY 150 SQ. FT. OF ATTIC SPACE BRICK BRICK BRICK BRICK 12 8 12 8 MAIN F.F. 100'-0" MAIN F.F. 100'-0" MAIN TOP PLATE 109'-0" MAIN TOP PLATE 109'-0" FAMILY ROOM T.P. 111'-0" GARAGE T.O.S. 98'-6" 12 8 12 8 SCALE 1/4"=1'-0" RIGHT ELEVATION 6' - 8 " ARCHITECTURAL SHINGLES BRICK BRICK BRICK BRICK BRICK 12 8 12 8 pr o j e c t : revisions: Project number Date Drawn by Engineered by 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. A1.1 MARCH 26, 2021 SO M M E R R E S I D E N C E LO T 4 B L O C K 1 PI N E B R O O K E S T A T E S RE X B U R G , I D CWD N/A EXTERIOR ELEVATIONS NOTES: 1. EXTERIOR WALL FINISHES MUST BE LISTED, LABELED, AND INSTALLED AS PER MANUFACTURER'S INSTALLATION INSTRUCTION GUIDES. 2. INSPECTION OF THE WEATHER-RESISTIVE BARRIER AND FLASHING IN ORDER TO PREVENT WATER FROM ENTERING THE WEATHER-RESISTANT EXTERIOR WALL ENVELOPE IS REQUIRED. R109.1.5 3. ALL FOOTINGS SHALL BEAR 30" OR 36" MIN. BELOW FINISH GRADE (VERIFY DEPTH WITH LOCAL CODES), BUT NO LESS THAN 12" BELOW NATURAL GRADE. 4. HOUSE DRAINAGE FINAL GRADES TO BE MIN. 6" OF FALL FOR FIRST 10' FROM HOME. Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft.Street Number Displayed on House AA5 . 1 AA5 . 1 2092 SQ. FT. (CRAWL SPACE) SCALE 1/4"=1'-0" FOOTING & FOUNDATION PLAN 28"x51" CRAWL SPACE ACCESS CRAWL SPACE NOTES: 1. DO NOT PROVIDE LOOSE BACK FILL UNTIL FLOOR FRAMING & BASEMENT SLAB ARE IN PLACE & CONCRETE FOUNDATION WALLS HAVE ACHIEVED AT LEAST 75% OF DESIGN STRENGTHS OR 1750 PSI. (VERIFY NUMBER OF DAYS TO REACH DESIRED STRENGTH FROM CONCRETE PROVIDER). 2. DO NOT PROVIDE COMPACTED BACK FILL UNTIL CONCRETE WALLS HAVE CURED AT LEAST 28 DAYS. 3. COORDINATE WITH MECHANICAL AND OTHER SUBCONTRACTORS CONCERNING PERFORATIONS IN CONCRETE WALLS FOR DUCTWORK, ETC. 4. PROVIDE 4" LEDGE AT FOUNDATION WALL FOR PORCH CAP (SUSPENDED OR OTHERWISE) W/ STEEL PER ENGINEERS SPECS. SEE DETAIL SHEET A5.0. 5. CONTRACTOR AND / OR PLUMBER TO VERIFY ELEVATION OF SEWER LATERAL BEFORE EXCAVATION. 6. GAS PIPE TO TIE TO MANIFOLD SYSTEM BY WHICH CODE REGULATORS WILL BE INSTALLED REDUCING 2 LB. PRESSURE TO 4 OZ. 7. PROVIDE 1 SQ. FT. OF CRAWL SPACE VENTILATION FOR EVERY 150 SQ. FT. OF CRAWL SPACE (TYP.) 8. SECURE TOP & BOTTOM 1/3 OF WATER HEATER W/ APPROVED SEISMIC STRAPS AND INSTALL EXPANSION TANK PER LOCAL REQUIREMENT 9. PROVIDE COMBUSTION AIR FROM OUTSIDE TO FURNACE & WATER HEATER 10.HOT WATER LINES TO HAVE 1/2" FOAM INSULATION UP TO FIREPLACE FURN. ABV. W.H. ABV. 3' - 6 " G A S L I N E 10'-6" GASLINE 39 ' - 4 " G A S L I N E GAS METER BLOCK OUT FOR DOOR RECESS FOUNDATION WALL & POUR SLAB THRU SLOPE 1/8"/FT. SL O P E 1/ 8 " / F T . SLOPE 1/8"/FT. 37'-0" GASLINE 1'-9"3'-0"25'-9" 14'-2"45'-4"30'-6" 90'-0" 31 ' - 1 0 " 11 ' - 6 " 12 ' - 0 " 55 ' - 4 " 6'-8"9'-0"2'-0"9'-0"3'-0" 14'-2"40'-10"5'-4"29'-8" 90'-0" 3' - 1 0 " 19 ' - 1 1 / 2 " 18 ' - 8 " 13 ' - 8 1 / 2 " 55 ' - 4 " 19'-2 3/4"19'-11 1/4" 12'-6"12'-9 1/4"19'-2 3/4" 18 ' - 1 1 1 / 4 " 17 ' - 4 1 / 2 " 13 ' - 6 1 / 4 " 4'-0" 6' - 8 " * 10" CMU FOUNDATION U.N.O. 6" C M U 6" CMU pr o j e c t : revisions: Project number Date Drawn by Engineered by 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. A2.0 MARCH 26, 2021 SO M M E R R E S I D E N C E LO T 4 B L O C K 1 PI N E B R O O K E S T A T E S RE X B U R G , I D CWD N/A FOOTING & FOUNDATION PLAN Tar house foundation. LIVING ROOM 9'-0" CLG.KITCHEN 9'-0" CLG. BEDROOM 9'-0" CLG. BEDROOM 9'-0" CLG. MASTER BEDROOM 9'-0" CLG. FAMILY ROOM 11'-0" CLG. DINING 9'-0" CLG. GARAGE 2179 SQ. FT. SCALE 1/4"=1'-0" MAIN FLOOR PLAN 916 SQ. FT. (GARAGE) AA5 . 1 AA5 . 1 BE N C H W/D BLOCK OUT CONC. & CMU FOUNDATION FOR HVAC REF DBL OVEN TUB SHWR SHWR+1 8 " R A I S E D P L A T F O R M CRAWL SPACE ACCESS MASTER BATH 9'-0" CLG. W.I.C. PANTRY LAUNDRY STORAGE MECH. COVERED PORCH BATH COVERED PATIO 2'-4" 3'-0" 2'-4" 2'-4" 5' - 0 " 3'-0" 2'-6" 2'-4" 2'-6" 9'-0"x8'-0" OVERHEAD 3'-0"x6'-8" TEMP. 6'-0"x6'-8" TEMP. 9'-0"x8'-0" OVERHEAD 5'-0" (3 ) 3 ' - 0 " x 5 ' - 0 " S . H . (3 ) 3 ' - 0 " x 5 ' - 0 " S . H . 3' - 0 " x 5 ' - 0 " S . H . 3' - 0 " x 5 ' - 0 " S . H . 3' - 0 " x 5 ' - 0 " S . H . 4'-0" 2'-8" 6'-0" 3' - 0 " x 5 ' - 0 " S . H . w / 3' - 0 " x 2 ' - 0 " T R A N S O M 3' - 0 " x 5 ' - 0 " S . H . w / 3' - 0 " x 2 ' - 0 " T R A N S O M 3'-0" 5'-0" (2) 3'-0"x5'-0" S.H. (2) 2'-0"x5'-0" S.H. TEMP. (2) 3'-0"x3'-0" S.H. TEMP. 3' - 0 " x 5 ' - 0 " S . H . FURN. W.H . 2'-0" TEMP. 2'-0" TEMP. CO O K T O P DB'L SINK w/ DISP. 22"X30" ATTIC ACCESS SLOPE 1/8"/FT. SL O P E 1/ 8 " / F T . SLOPE 1/8"/FT. D.W. FIREPLACE 6" CMU w/ BRICK 2x6 w/ BRICK 6" C M U w / B R I C K 6" C M U w / B R I C K 6" CMU w/ BRICK 2x6 w/ BRICK 2x 6 w / B R I C K 2x6 w/ BRICK2x6 w/ BRICK 6" CMU 6" CMU 6" C M U 2x 6 2x6 ENTRY 9'-0" CLG. 11 ' C L G . 9' C L G . 2'-11"26'-11"9'-5"3'-8"6'-3 1/4"5'-9 3/4" 5'-5 1/2"12'-1"13'-1"14'-6 1/2" 2'-0"11'-2 1/2"1'-6"45'-2"29'-10" 89'-8 1/2" 5' - 8 " 5 ' - 6 " 5 ' - 6 " 7 ' - 3 " 7' - 3 " 2 ' - 5 " 2 ' - 0 1 / 2 " 2 ' - 7 " 2 ' - 3 1 / 2 " 7 ' - 0 " 7' - 0 " 4' - 5 1 / 2 " 4 ' - 1 0 1 / 2 " 14 ' - 0 " 16 ' - 8 " 14 ' - 6 " 23 ' - 4 " 54 ' - 6 " 2'-0" 3'-10 1/2" 9' - 1 0 1 / 2 " 2 ' - 0 " 9'-9"15'-9"7'-2"9'-0"2'-0"9'-0"4'-8" 25'-6"14'-4"5'-4"31'-10" 2'-0"11'-2 1/2"1'-6"39'-10"37'-2" 91'-8 1/2" 9' - 9 1 / 2 " 9' - 4 " 2 ' - 1 0 1 / 2 " 2 ' - 7 1 / 2 " 2' - 7 1 / 2 " 2 ' - 7 " 6 ' - 1 1 " 7' - 1 " 19 ' - 1 1 / 2 " 5' - 6 " 5' - 2 1 / 2 " 14 ' - 0 " 24 ' - 7 1 / 2 " 6' - 8 " 19 ' - 2 1 / 2 " 4' - 0 " 18 ' - 7 " 2' - 0 " 14 ' - 9 " 2' - 0 " 13 ' - 2 " 54 ' - 6 " 6' - 9 " 4 ' - 3 " 3 ' - 3 1 / 2 " 4 ' - 4 1 / 2 " 5 ' - 9 1 / 2 " 7 ' - 0 " 4 ' - 7 " 2 ' - 3 1 / 2 " 3 ' - 1 1 / 2 " 3 ' - 0 " 3 ' - 1 1 / 2 " 2 ' - 0 " 6' - 6 " 4 ' - 6 " 1 1 " 2 ' - 4 1 / 2 " 4 1/2"18'-7"2'-11 1/2"3'-1"2'-4"11'-7"5'-9 1/2" 6'-3 1/2"3'-3 1/2"3'-6"4'-0 1/2"8'-0 1/2"5'-5 1/2" 11'-6 1/2"8'-6"3'-0"2'-0" 4'-6" 6' - 0 " 12 ' - 0 " 5' - 6 " 6 ' - 8 " 1'-0 1/2"3'-0"6 1/2" 8'-0" 2'-0" 1'-7 1/2"2'-6"8"4'-0"8"2'-6"1'-7 1/2" VENT DRYER TO OUTSIDE 20 MIN. w/ CLOSER ELEC. PANEL 4'-0" 6' - 2 " NOTES: 1. EXTERIOR WALL FRAMING TO BE 2X6, INTERIOR WALL FRAMING TO BE 2X4 U.N.O. 2. PROVIDE 20 MIN. RATED DOOR w/ CLOSER @ DOOR BETWEEN GARAGE AND HOUSE. 3. ALL CONCRETE STEPS TO HAVE A MIN. RUN OF 11" 4. PROVIDE 36" LANDING w/ 1 1/2" MAX. DROP BETWEEN THRESHOLD AND LANDING (7 3/4" MAX. DROP IF DOOR SWINGS IN). -IRC 2018, R311.3 5. DRYER EXHAUST NOTE: THE MAX. LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE WALL OR ROOF TERMINATION. THE MAX. LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET FOR EACH 45-DEGREE BEND AND 5 FEET FOR EACH 90-DEGREE BEND. THE MAX. LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT. -IRC 2018, M1502.4.5 6. PROVIDE INSULATION ON WATER LINES ON EXTERIOR WALLS TO PREVENT FREEZING 7. SECURE TOP & BOTTOM 1/3 OF WATER HEATER W/ APPROVED SEISMIC STRAPS AND INSTALL EXPANSION TANK PER LOCAL REQUIREMENT 8. PROVIDE COMBUSTION AIR FROM OUTSIDE TO FURNACE & WATER HEATER 9. HOT WATER LINES TO HAVE 1/2" FOAM INSULATION 10.PROVIDE SAFE PAN BENEATH FURNACE pr o j e c t : revisions: Project number Date Drawn by Engineered by 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. A3.0 MARCH 26, 2021 SO M M E R R E S I D E N C E LO T 4 B L O C K 1 PI N E B R O O K E S T A T E S RE X B U R G , I D CWD N/A MAIN FLOOR PLAN 20 min doors SD CO SD SD SD AA5 . 1 AA5 . 1 SCALE 1/4"=1'-0" MAIN FLOOR FRAMING PLAN 11 7/8" TJI/210 @ 16" O.C. pr o j e c t : revisions: Project number Date Drawn by Engineered by 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. A4.0 MARCH 26, 2021 SO M M E R R E S I D E N C E LO T 4 B L O C K 1 PI N E B R O O K E S T A T E S RE X B U R G , I D CWD N/A MAIN FLOOR FRAMING PLAN AA5 . 1 AA5 . 1 (11' CLG.) PRE-MANUFACTURED TRUSSES @ 24" O.C. GI R D E R T R U S S SCALE 1/4"=1'-0" ROOF FRAMING PLAN GI R D E R T R U S S OV E R - B U I L D GI R D E R GIRDER GIRDER OV E R B U I L D OV E R B U I L D GIRDER GIRDER pr o j e c t : revisions: Project number Date Drawn by Engineered by 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. A4.1 MARCH 26, 2021 SO M M E R R E S I D E N C E LO T 4 B L O C K 1 PI N E B R O O K E S T A T E S RE X B U R G , I D CWD N/A ROOF FRAMING PLAN Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) ANY ENGINEERING NOTES AND SPECIFICATIONS SUPERSEDE THESE NOTES AND CALL-OUTS NOTE: GENERAL NOTES: 1 . CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL ADOPTED CODES AND REGULATIONS SET FORTH BY THE JURISDICTION IN WHICH CONSTRUCTION TAKES PLACE. 2. PROVIDE ATTIC ACCESS CLEAR OPENING OF 22"X30". ACCESS SHALL NOT BE LOCATED ABOVE A CLOSET SHELF AND SHALL HAVE 30" MIN. HEAD ROOM. 3. CEMENT, FIBER-CEMENT, OR GLASS MAT GYPSUM BACKERS ARE REQUIRED AS A BACKER FOR WALL TILE IN TUB & SHOWER AREAS & WALL PANELS IN SHOWER AREAS. R702.4.2 4. INSTALL 5/8" TYPE "X" GYP. ON ALL WALLS, CEILING, BEAMS AND SUPPORTS IN GARAGE FOR FIRE PROTECTION BETWEEN HOUSE AND GARAGE. (INSTALL (2) LAYERS OF TYPE 'X' GYPSUM BOARD PERPENDICULAR TO CEILING FRAMING FOR GARAGE CEILINGS BENEATH HABITABLE ROOMS. OTHERWISE EITHER DIRECTION WILL SUFFICE.). EACH SHEET TO BE NAILED 4" O.C. AT EDGES AND 6" O.C. IN FIELD. 5. ATTIC VENTILATION AS FOLLOWS: 1 SQ. FT./150 SQ. FT. OF ATTIC AREA. 6. ALL FOOTINGS SHALL BE PLACED 12" BELOW UNDISTURBED EARTH AND A MIN. OF 30" BELOW FINISHED GRADE OR AS NOTED ON PLAN. TOP OF FOUNDATION TO BE A MIN. 6" ABOVE FINISHED GRADE. FINISHED GRADE TO HAVE A MIN. 6" SLOPE AWAY FROM BUILDING FOR FIRST 10 FEET. ALL DRAINAGE FROM LOT TO DRAIN INTO APPROVED DRAINING SYSTEM. 7. METAL FLASHING REQ'D FOR MASONRY VENEER REQ'D FROM FOUNDATION UP THE FIRST THREE COURSES, & 3/16" WEEP HOLES 33" O.C. FLASHING TO EXTEND BEYOND FOUNDATION EDGE 1/2". WINDOWS :1 . BEDROOM WINDOWS SHALL HAVE A MIN. CLEAR OPENING OF 5.7 SQ. FT. WITH A MIN. NET CLEAR OPENING WIDTH OF 20" (FOR A TALL WINDOW) AND A MIN. NET CLEAR OPENING HEIGHT OF 24" (FOR A WIDE WINDOW) AND A FINISHED SILL HEIGHT NOT TO EXCEED 44" ABOVE THE FINISHED FLOOR. 2. GLASS USED IN TUB OR SHOWER ENCLOSURES TO BE FULLY TEMPERED. 3. TEMPERED GLASS SHALL BE USED IN ALL GLASS DOORS, GLASS IN DOORS, WINDOWS OVER BATHTUBS, WINDOWS WITHIN 18" OF THE FLOOR, GLAZING IN GUARD RAILINGS, AND WINDOWS WITHIN 24" OF ANY DOOR. 4. PROVIDE 9" FLASHING AROUND ALL WINDOWS & DOORS WITH SILL PLATE FLASHING. 5. FLASH & CAULK AROUND ALL EXTERIOR WINDOWS & DOORS PER MANUFACTURERS RECOMMENDATIONS. MECHANICAL: 1 . COMBUSTION AIR TO BE TAKEN FROM OUTSIDE. 2. COMBUSTION AIR DUCTS TO BE LOCATED WITHIN THE UPPER 12" OF CEILING AND WITHIN 12" OF THE FLOOR. 3. DUCTS USED FOR COMBUSTION TO REMAIN SEPARATE FROM THE ENCLOSURE TO THE OUTSIDE AIR SOURCE. 4. FURNACES IN A CLOSET SHALL HAVE A MIN. 3" CLEAR WORKING SPACE ON SIDES, BACK AND TOP. 5. VENTS SHALL TERMINATE 4' BELOW, OR 4' HORIZONTALLY AND AT LEAST 1' ABOVE A DOOR, OPERABLE WINDOW, OR GRAVITY AIR INLET INTO A BUILDING. 6. FLUE AND EXHAUST FAN VENTS SHALL BE AT LEAST 3' ABOVE AN OUTSIDE AIR INLET LOCATED WITHIN 10' AND AT LEAST 4' FROM PROPERTY LINE. 7. MIN. 30" CLEARANCE REQ'D ABOVE RANGE TOP TO COMBUSTIBLES. 8. EXHAUST FANS PROVIDING 5 AIR CHANGES PER HOUR TO BE INSTALLED IN BATHROOMS AND LAUNDRY ROOM WITHOUT AN OPERABLE WINDOW. 9. RESIDENTIAL HEATING DUCT JOINTS TO BE FASTENED WITH AT LEAST 3 SHEET METAL SCREWS EVENLY SPACED. SUPPORT DUCTS WITH APPROVED META SUPPORTS. 10. PROVIDE COMBUSTION AIR TO LAUNDRY AREA. PLUMBING: 1 . PROVIDE SEISMIC STRAPS ON WATER HEATER. 2. ALL TOILETS TO BE LOW-FLUSH TYPE. MAX. 1.6 GAL. PER FLUSH. 3. MAX. FLOW RATE FOR SHOWER HEADS TO BE 2.5 GAL. PER MINUTE. 4. PROVIDE OUTSIDE COMBUSTION AIR FOR WATER HEATER. 5. PLUMBING VENTS SHALL BE AT LEAST 3' ABOVE OR 10' AWAY FROM ALL OUTSIDE AIR INTAKE OPENINGS. 6. FLAG POLING OF PLUMBING VENTS IS PROHIBITED EXCEPT WHERE ROOM IS OCCUPIED. 7. ALL HOSE BIBS TO BE FREEZE LESS AND HAVE BACK FLOW PREVENTOR. 8. PLUMBING PENETRATIONS THROUGH GARAGE FIRE WALL MUST BE WITH METAL PIPING. 9. NO SLIP JOINT PLUMBING CONNECTIONS ALLOWED IN CONCEALED CONSTRUCTION AREAS. (BATH TUBS). 10. INDIVIDUALLY INSULATE WALL PLUMBING, WATER, DRAIN LINES IN AREAS SUBJECT TO FREEZING. EXTERIOR WALLS, ATTICS, CRAWL SPACES, GARAGES. ELECTRICAL: 1 . SMOKE DETECTORS AT EACH BEDROOM, AT HALLWAYS LEADING TO BEDROOMS, AT EVERY FLOOR LEVEL INCLUDING BASEMENTS, AT THE TOP OF EACH STAIRWAY ON FLOORS WITHOUT BEDROOMS, AND IN ROOMS SERVING BEDROOMS WHERE THE CEILING HEIGHT OF THE ROOM IS 24" OR GREATER IN HEIGHT THAN THE BEDROOM SERVED FROM SUCH ROOM. SMOKE DETECTORS SHALL BE HARD WIRED TOGETHER IN SERIES W/ BATTERY BACKUP. 2. BATHROOM RECEPTACLE OUTLETS SHALL BE SUPPLIED BY DEDICATED 20 AMP BRANCH CIRCUIT W/ NO OTHER OUTLETS. 3. ELECTRICAL RECEPTACLE OUTLETS SHALL BE SUPPLIED WITHIN 25' OF HVAC EQUIPMENT (IRC - E3801.11). 4. LIGHTS IN CLOSETS SHALL CONFORM TO CLEARANCES SPECIFIED PER CODE 5. TEMP. WIRING SHALL CONFORM TO APPLICABLE CODE. 6. ANY LIGHT FIXTURES OVER TUBS AND SHOWERS SHALL COMPLY WITH CURRENT CODE REQUIREMENTS. 7. ALL CEILING FANS TO HAVE FAN RATED BOX. 8. ALL KITCHEN SURFACE OUTLETS, BATH OUTLETS, GARAGE OUTLETS, OUTLETS OUTDOORS WITH DIRECT GRADE LEVEL ACCESS INCLUDING DECKS, BALCONIES, UNDER EAVES, CRAWL SPACES, AND IN UNFINISHED BASEMENTS TO BE GFI. FRAMING: 1 . SOLID BLOCKING BETWEEN JOISTS, RAFTERS, AND TRUSSES OVER BEARING WALLS. 2. PROVIDE DOUBLE JOISTS UNDER BEARING WALL LOCATIONS WHERE SUCH WALLS ARE PARALLEL WITH JOISTS. TYP. WALL SECTION TOP OF FOOTING TOP OF FOUNDATION WALL MAIN FINISH FLOOR TOP PLATE PE R P L A N PE R P L A N PER PLAN PER PLAN SCALE 3/4" = 1'-0" 2X TREATED PLATE W/ ANCHOR BOLTS SPACED PER ENGINEERING CALCULATIONS. 3/4" T & G WAFERWOOD OVER FLOOR JOISTS, GLUE & NAIL. SEE FLOOR FRAMING PLAN FOR JOIST SIZE & SPACING 8" CONC. FOUNDATION WALL w/ APPROVED WATER RESISTANT EMULSION FOOTING PER SCHEDULE 4" CONC. SLAB OVER APPROVED SOIL ALUM. SOFFIT (VENTED) STUCCO SYSTEM OR SIDING OVER MIN. (2) LAYERS OF NO. 15 ASPHALT FELT OVER WAFERWOOD OVER 2x STUDS SPACED PER ENGINEERS CALCS. w/ INSUL. NOTE: EXTERIOR WALL FINISHES MUST BE LISTED, LABELED, AND INSTALLED AS PER MANUFACTURER'S INSTALLATION INSTRUCTION GUIDES. RIM JOIST W/ BLOCKING SIMPSON H1 ANCHOR EVERY TRUSS 2X FASCIA BD. w/ ALUMINUM DRIP EDGE SOLID 2X BLOCKING INSTALL ICE & WATER SHIELD PER LOCAL CODE - ICE & WATER SHIELD MUST EXTEND FROM THE EDGE OF THE EAVES TO A POINT NOT LESS THAN 24" INSIDE THE EXTERIOR WALL LINE ASPHALT SHINGLES OVER (1) LAYER OF NO. 15 FELT OVER WAFERWOOD (GAP 1/8" USE H-CLIPS) OVER TRUSSES INSUL. BAFFLE R-38 INSUL. MIN. SEE RESCHECK MID-HEIGHT BLOCKING @ BEARING WALLS R-19 INSULATION MIN. SEE RESCHECK R-19 INSULATION MIN. SEE RESCHECK HOUSE DRAINAGE FINAL GRADES TO BE MIN. 6" OF FALL FOR FIRST 10' FROM HOME. MIN. STAIR REQUIREMENTS HANDRAIL: 1 1/4"-2 5/8" DIA. CROSS SECTIONAL DIMENSION RETURN ENDS TO WALL GUARDRAIL TO BE MINIMUM HEIGHT OF 36" AND HAVE NO NET OPENINGS EXCEEDING 4" ON VERTICAL BALUSTERS SCALE 1/2"=1'-0" (3) 2" X 12" PARALLAM STRINGERS 1/2" TYPE "X" GYP. 2" X 4" REDWOOD OR TREATED PLATEF.F. PER PLAN JOIST PER PLAN 10" MIN. 73/4" MA X . 6' - 8 " MI N . H E A D R O O M 34 " 3 8 " MI N . M A X . 3/4" MIN. TO 1 1/4" MAX. NOSING: WINDOW WELL REQUIREMENTS 36" MIN. 36" MI N. NOTES: 1 . WINDOW WELL REQUIRED FOR ESCAPE AND RESCUE WINDOWS WITH FINISHED SILL HEIGHT BELOW THE ADJACENT GROUND ELEVATION. 2. ALL WINDOW WELLS WITH A VERTICAL DEPTH OF MORE THAN 44" SHALL BE EQUIPPED WITH A PERMANENTLY AFFIXED LADDER. ALL LADDERS MUST HAVE A 14 MIN. WIDTH, 14" MAX. SPACE BETWEEN RUNGS AND A 6" MIN. TOE SPACE. 3. ANY GRATES, BARS, GRILLS, DOMES OR SIMILAR DEVICES ON WINDOW WELLS REQUIRE AN APPROVED RELEASE MECHANISM. 4. EGRESS/RESCUE WINDOWS ARE REQUIRED TO BE 5.7 SQ.FT. CLEAR OPEN WITH A MIN. NET CLEAR OPENING WIDTH OF 20" (FOR A TALL WINDOW), AND A 5. EGRESS/RESCUE WINDOWS ARE REQUIRED IN EVERY BEDROOM AND AT LEAST ONE IN A BASEMENT. VERIFY WINDOWS MEET EGRESS AS INDIVIDUAL MANUFACTURERS MAY VARY IN NET CLEAR OPENING. LADDER - WHEN REQUIRED 9 SQ. FT. NET CLEAR DIMENSION (36" SMALLEST DIR.) WHEN WINDOW IS FULLY OPEN SCALE 1/2"=1'-0" APPROVED WINDOW WELL WALL DETAIL - 4" LEDGE @ PORCH CAP 4" 6" MA X . SCALE 1/2"=1'-0" METAL FLASHING STORAGE OR COMPACTED GRADE PER PLAN REINFORCING PER ENGINEERS SPECS. 6" MIN. SLAB SLOPE TO DRAIN FDN. WALL PER PLAN MAINTAIN 4" LEDGE FOR PORCH CAP (THICKEN WALL AS REQ'D) DETAIL-TYP. CONC. PEDESTAL FTG. SIZE & REINF. PER SCHED. AS R E Q ' D F O R UN D I S T U R B E D B E A R I N G OR F R O S T D E P T H WH I C H E V E R I S G R E A T E R SOIL BRG. EXTERIOR HARDSCAPE #4 DOWELS-EXTEND FULL HEIGHT OF PEDESTAL #3 TIES @ 10" O.C. UNDISTURBED 1/2" EXPANSION MAT'L 1" CHAMFER SCALE 1"=1'-0" PER PLAN COLUMN PER PLAN 2" MIN. SLOPE 1.5% FROM EXTERIOR WALL OF HOUSE TO FRONT OF PORCH "B" DECK BASE. PROVIDE A MIN 2" OVERAGE AT FOUNDATION WALLS PROVIDE A 1" OVERHANG AT PORCH CAP OVER FOUNDATION WALL SEE ENGINEERING FOR PORCH CAP RE-FORCING PROVIDE A MIN. OF 12" ICE AND WATER SHIELD OVER WEATHER BARRIER BETWEEN PORCH CAP AND EXPOSED FRAMING. RUN DOWN TO TOP OF FOUNDATION WALL. 24 GA. 4"X4" LEG GALV. FLASHING FROM WALL TO BELOW CULTURED STONE VENEER. CAULK BETWEEN PORCH CAP AND FLASHING PORCH CAP DETAIL SCALE = N.T.S. MIN. NET CLEAR OPENING HEIGHT OF 24" (FOR A WIDE WINDOW). MIN. HEIGHT FROM FLOOR TO CLEAR OPENING NOT TO EXCEED 44". 44 " M A X . T O CL E A R O P E N I N G TYP. TRUSS HEEL SCALE = N.T.S. PE R PL A N pr o j e c t : revisions: Project number Date Drawn by Engineered by 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. A5.0 MARCH 26, 2021 SO M M E R R E S I D E N C E LO T 4 B L O C K 1 PI N E B R O O K E S T A T E S RE X B U R G , I D CWD N/A SECTIONS also on 4' walls ? 8" x 20" MAIN F.F. 100'-0" MAIN F.F. 100'-0" MAIN TOP PLATE 109'-0" MAIN TOP PLATE 109'-0" FAMILY ROOM T.P. 111'-0" GARAGE T.O.S. 98'-6" SCALE 1/4"=1'-0" SECTION 'A' 12 10 12 10 CRAWL SPACE CRAWL SPACE CL G . 11 ' - 0 " CL G . 9' - 0 " SLOPE TO DRAIN SLOPE TO DRAIN pr o j e c t : revisions: Project number Date Drawn by Engineered by 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. A5.1 MARCH 26, 2021 SO M M E R R E S I D E N C E LO T 4 B L O C K 1 PI N E B R O O K E S T A T E S RE X B U R G , I D CWD N/A SECTIONS WP/GFI WP/GFI WP / G F I GF I 20 " MI N . GFI 20" MIN. GF I 20 " MI N . 220 22 0 220GFI GFI GF I GF I GF I GFIGFIGFI GF I GF I GFI GFI GF I GFI SCALE 1/4"=1'-0" MAIN FLOOR ELECTRICAL PLAN ELEC. PANEL 3 WAY SWITCH DUPLEX RECEPTACLE OUTLET - TAMPER RESISTANT CARBON MONOXIDE DETECTOR EXHAUST FAN - VENT TO OUTSIDE SURFACE MOUNT LIGHT FIXTURE GROUND FAULT INTERCEPT DUPLEX RECEPTACLE OUTLET WATER PROOF G.F.I. DUPLEX RECEPTACLE OUTLET SMOKE DETECTOR WIRE IN SERIES W/ BATTERY BACK-UP ELECTRICAL LEGEND GFI WP/GFI 3 CO S NOTES: ALL OUTLETS MUST BE TAMPER RESISTANT PER 2017 NEC. ALL BEDROOM OUTLETS, LIGHTS, SWITCHES & SMOKE DETECTORS SHALL BE ARC-FAULT PROTECTED. FIELD DETERMINE LOCATION OF ALL SWITCHES. PROVIDE METALLIC WATER SERVICE & CONCRETE ENCASED ELECTRODE PER 2017 NEC. PROVIDE BUBBLE COVERS ON ALL EXTERIOR OUTLETS. INSTALL 110V OUTLET WITHIN 25' OF A/C UNIT. INSTALLATION OF ALL ELECTRICAL COMPONENTS SHALL COMPLY WITH THE 2017 NEC REQUIREMENTS INCLUDING THE PLACEMENT OF OUTLETS AS SPECIFIED IN CHAPTER 2 AND WIRING METHODS AS SPECIFIED IN CHAPTER 3 (I.E. RECEPTACLES ARE REQUIRED WITHIN 6' OF WALL ENDS AND VERTICAL EDGES OF DOORWAYS AND ON ALL WALL SECTIONS AT LEAST 2' WIDE). 220 V. OUTLET PENDANT LIGHT FIXTURE RECESSED CAN LIGHT CLG. FAN W/ LIGHT 2'X4' FLUORESCENT LIGHT FIXTURE WP WP CO GFI GFIGFI PWR FOR D.W. PWR FOR DISP. POWER FOR GARAGE DOOR OPENER pr o j e c t : revisions: Project number Date Drawn by Engineered by 7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885 CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION. NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK. EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR. THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE. E1.0 MARCH 26, 2021 SO M M E R R E S I D E N C E LO T 4 B L O C K 1 PI N E B R O O K E S T A T E S RE X B U R G , I D CWD N/A MAIN FLOOR ELECTRICAL PLAN