Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED FA SUBMITTAL & DRAWINGS - 23-00596 - BYUI Romney Building - Fire Alarm
Author Name Author Email Author Phone No.: Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : BYUI Romney Building - Fire Alarm Address : 5 W 2nd S Record Type : Fire System Construction Permit Document Filename : Romney Building Remodel Fire Alarm Submittal.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00596 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 1 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector 29 Stamp Alex Owens : Electrical Open 29 Approved - Electrical Inspector 31 Stamp Alex Owens : Electrical Open 31 Approved - Electrical Inspector Fire System Construction Permit Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) FIRE CONTROL INSTRUMENTS-GAMEWELL-BOSCH 1481 SOUTH MAJOR STREET S.L.C., UT 84115 P. 801-468-8300 F. 801-468-8305 Romney Building Remodel - BYU-I 281 S Center Street Rexburg, ID. 83440 Romney 2023 Remodel BYU-I Fire Alarm System Submittal & Drawings PROJECT Equipment Manufacturer: Gamewell-FCI Romney Building Remodel Authorized Distributor: Nelson Fire Systems BYU-I 1481 S Major St Fire Alarm System SLC, UT 84115 801-468-8300... Romney Building Remodel - BYU-I 281 S Center Street Rexburg, ID. 83440 TABLE OF CONTENTS Data Sheet Part No. Description DEVICES: Gamewell-FCI MS-7AF Addressable Pull Station Gamewell-FCI AOM-2SF Addressable Supervised Control Module Gamewell-FCI PR-1 Relay Gamewell-FCI SPSCWL White Speaker/Strobe – Ceiling Mount Battery Calculations E3 System Battery Calc HPFF8 Battery Calc CKT Voltage Drops Drawings Sheet No. Description Cover Page FA-C-01 Fire Alarm Cover Riser Diagram FA-R-01 Fire Alarm Riser and Matrix Basement FA-1-01 Addressable Circuits Basement FA-1-02 Notification Circuits Basement FA-1-03 Addressable Numbers Level 2 FA-2-01 Notification Circuits Devices MS-7 Series MS-7 Series Manual Fire Alarm Pull Stations Addressable Devices General The Gamewell-FCI, MS-7 Series manual fire alarm pull stations are available in a wide variety of configurations. The pull stations comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All pull stations include a key lock/reset which is keyed alike with the Gamewell-FCI fire alarm control panels and other manual fire alarm pull stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a double action pull station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the pull station causes its assigned address to register at the fire alarm control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The station features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.* The station features screw terminals. The Velociti® Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and focuses on the single device. The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • Conventional stations suitable for use with any UL® Listed control panel • The pull stations (MS- 7LOB) are Listed for outdoor applications • Complies with ADA pull force requirements • Offers surface or semi- flush mounting • Shock and vibration resistant • Both single and double action pull stations available • Includes a tumbler lock for test and reset keyed alike with analog addressable fire alarm controls *Only the red LED is operative in panels that do not operate in Velociti mode 2 MS-7S Single Action Station The MS-7S single action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station, with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabilities are required. It consists of the following: • An MS-7LR mounted on a plate with an abort switch • LED indicators that signal system normal and system activated status MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-I/O backbox. In retrofit applications, the pull station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior pull stations may be surface mounted or semi-flush mounted on a standard double-gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi-flush mounting. NYC-Plate The NYC-Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC-Plate Ordering Information MS-7: Double action station MS-7AF**: Velociti addressable double action station MS-7ASF**: Velociti addressable single action station MS-7S: Single action station, wire leads MS-7SP: Double action station, English and Spanish instructions MS-7LR: Agent release station, dual-action MS-7LRA: Agent release station with abort switch, LED indicators, dual- action MS-7LOB: Double action station, outdoor use (Includes SB-I/O - Indoor/outdoor use backbox) SB-I/O: Indoor/outdoor use backbackbox SB-10: Surface backbox BG12TR: Trim ring for semi-flush mount, plastic NY-PLATE: NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. MS-7 Series Technical Specifications 9020-0616 | F | 11/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Velociti® and Gamewell-FCI are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s MS-7 Series and other products available by visiting www.Gamewell-FCI.com SYSTEMS Material: Lexan® Contact Ratings: 0.25 amps. @ 30 VAC/VDC (resistive) Dimensions: 5 5/8” H x 4 1/4” W x 1 1/4” D (14 x 10.1 x 3.2 cm) Operating Temperature: (MS-7AF, MS-7ASF): 32° to 120° F (0° to 49° C) (MS-7LOB): -30° to 150° F (-35° to 66° C) Relative Humidity : (MS-7AF, MS-7ASF): 10 to 93% (non-condensing) (MS-7LOB): 85% ± 5% @ 86° ± 3.6° (30° ± 2° C) Alarm Current: .0030 amp. 0.007 for LED Supervisory Current: (MS-7AF, MS-7ASF): .00030 amps. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The MS-7 Series is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2465 FM: 3023594 MEA FDNY: 67-02-E Vol. VII CSFM: 7160-1703:0119 7160-1703:0170 7160-1703:0109 ISO 9001 Certification AOM-2SF VELOCITI® SERIES AOM-2SF Addressable Output Relay Supervised Control Module GENERAL The Gamewell-FCI Velociti® Series addressable output supervised control module (AOM-2SF) allows a Gamewell-FCI analog addressable fire alarm control panel to switch an external power supply, such as a DC supply or audio amplifier (up to 80 VRMS) to notification appliances. The AOM-2SF notification appliance circuit can be wired either Class A or Class B. It also supervises the wiring to the connected loads and reports their status to the panel as NORMAL, OPEN or SHORT CIRCUIT. The module contains a panel controlled LED. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the SLC devices and certain Gamewell-FCI analog addressable fire alarm control panels. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net result is a superior response speed up to five times greater than the earlier designs. The AOM-2SF module is designed for installation in the signaling line circuit of any Gamewell-FCI analog addressable fire alarm control panel. The signaling line circuits of Gamewell-FCI analog addressable fire alarm control panels are designed to accommodate up to 159 modules per circuit. The AOM-2SF is designed to mount in a 4” (10.16 cm) square junction box 2 1/8” (5.5 cm) deep. Table 1 lists the relay contact ratings. Ordering Information AOM-2SF: Addressable output supervised control module FEATURES AND BENEFITS • Listed under UL ® 864, 10 Edition Standard • Complies with UL 2572, 2nd Edition Standard for Mass Notification • Designed as a compact size to allow easy installation • Includes Class A or Class B notification appliance circuit • Accommodates audio amplifiers up to 80 VRMS • FM Listed as suitable for a releasing device service • Includes a bi-color LED that flashes green whenever the module is addressed, and lights steady red upon activation* The AOM-2SF is an addressable output, supervised, control module used with the Gamewell-FCI panels. Current Rating Maximum Voltage Load Description Application 3A 30 VDC Resistive Non-Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non-Coded 0.5A 125 VAC Resistive Non-Coded 0.5A 30 VDC Inductive (L/R=5ms) Coded 1A 30 VDC Inductive (L/R=2ms) Coded 0.5A 125 VAC Inductive (PF=.35) Non-Coded 0.7A 75 VAC Inductive Non-Coded Table 1: Relay Contact Ratings VELOCITI® SERIES AOM-2SF TECHNICAL SPECIFICATIONS 9020-0627 | J | 06/20 ©2020 Honeywell International Inc. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.gamewell-fci.com E3 Series® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: U.S.A. *Note 1: Only the red LED is operative in panels that do not operate in Velociti® mode *Note 2: The bi-color LED functionality is not available on the GWF-7075 panel. SYSTEM Supervisory Current: 0.00375 amps Alarm Current: .0065 amps Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 10 to 93% relative humidity (non-condensing) Dimensions: 4 1/2” H x 4” W x 1 1/4” D (11.4 H x 10.2 W x 3.2 D cm) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The Velociti Series AOM-2SF are designed to comply with the following standard: UL Standards: UL 864, 10th Edition UL 2572, 2nd Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S1949 UL 864, 10th Edition UL 2572, 2nd Edition FM: 3023594 MEA FDNY: 227-03-E Vol. IV CSFM: 7300-1703:0102 ISO 9001 Certification Agency Listings Multi-Voltage Conventional Relays System Sensor’s multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features Multi-voltage operation Activation LEDs Easy and flexible installation Reliable and robust design Multipurpose field installations Multi-voltage relays with terminal strip field wiring connections, mounting track, and hardware for R-10T/20T and R-14T/24T Removable front cover on steel enclosure for R-10E/R-20E and R- 14/R-24E, which mount inside the enclosure LED viewing hole on top of the steel enclosure’s cover Extra pair of wires for redundant power input on PR-3 Terminal strip field wiring connections, mounting track, and hardware • • • • • • • • • • The R-10T, R-20T, R-14T, and the R-24T models are multi- voltage relays with terminal strip field wiring connections, mounting track, and hardware. The R-10T is a single FORM–C (SPDT) relay with a red activation LED, and the R-14T is a four-gang 1 FORM–C (SPDT) relay with four red activation LEDs. The R-20T is a single 2 FORM–C (DPDT) relay with a red activation LED, and the R-24T is a four-gang 2 FORM–C (DPDT) relay with four red activation LEDs. The R-10E/R-20E and R-14E/R-24E are similar to the T-series track mount relays, but they are mounted into a steel enclosure. The enclosure has a removable front cover that provides easy access and an LED viewing hole on the top of the cover. PR-1/PR-2/PR-3 are epoxy encapsulated multi-voltage relays. They are single-pole double-throw relays that use a red LED as a visible indication of relay coil energization. PR–3 is identical to PR–2, except it has an extra pair of wires for redundant power input. Model EOLR-1 is an epoxy encapsulated, single-pole single-throw, normally open relay that can be used as an end of line device in fire alarm systems, e.g. to supervise power supplies. 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2007 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0372-005 • 3/07 • #1782 Specifications: R-10T/R-14T/R-20T/R-24T Operating Voltage 18 – 35 VDC, 18 – 35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-10T/R-14T) 40 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20T/R-24T) Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10% – 93% non-condensing Dimensions R-10T/R-20T: 2.5˝L × 3.35˝W × 1.2˝H R-14T/R-24T: 10˝L × 3.35˝W × 1.2˝H Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10 A 120 VAC: 1/6 HP 230 VAC: 7 A Specifications: R-10E/R-14E/ R-20E/R-24E Operating Voltage 18 – 35 VDC, 18 – 35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-10E/R-14E) 40 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20E/R-24E) Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10% – 93% non-condensing Dimensions R-10E/R-20E: 5.1˝L × 3.75˝W × 2.5˝H R-14E/R-24E: 11˝L × 5.3˝W × 2.5˝H Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10 A 120 VAC: 1/6 HP 230 VAC: 7 A Multi-Voltage Conventional Relay Specifications PR–1 E0LR–1 PR–3 PR–2 R–10T R–14T R-10E & R-20E Enclosure R-14E & R-24E Enclosure Specifications: PR-1 Operating Voltage 18 – 35 VDC, 18 – 35 VAC, 120 VAC Operating Current 15 mA DC max. @ 24 VDC, 24 VAC, 120 VAC Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10 – 93% RH Wire Length 8˝ minimum Dimensions 0.87˝H × 2.01˝W × 1.42˝D Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive 30 VDC: 10 A resistive Specifications: PR-2/PR-3 Operating Voltage 10 to 40 VDC Operating Current 30 mA DC max. Operating Temperature –40°F to 158°F (–40°C to 70°C) Humidity Range 10 – 93% RH Wire Length 8˝ minimum Dimensions 0.91˝H × 1.65˝W × 1.22˝D Contact Ratings 120 VAC: 10 A max. (resistive load) 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load) 30 VDC: 10 A max. (resistive load) Specifications: EOLR-1 Operating Voltage 9 to 40 VDC Operating Current 20 mA DC max. Operating Temperature –22°F to 140°F (–30°C to 60°C) Humidity Range 10 – 93% RH Wire Length 8˝ minimum Contact Ratings 120 VAC: 0.5 A max. (resistive load) 30 VDC: 3 A max. (resistive load) Ceiling Speaker Strobes L Series, Indoor Ceiling Strobes and Dual Speakers Indoor Output Speaker Strobes and Dual Speakers for Ceiling Applications Notification Appliances General The L-Series indoor selectable-output speaker strobes and dual-voltage evacuation speakers offer a modern, aesthetic plug-in design that reduce costly ground faults. The universal mounting plate can be used in ceiling applications and its flexible design enables the Installer to easily perform the following: • Pre-wire mounting plates •Dress the wires Confirm wiring continuity before the Installer plugs-in the speakers. In addition, this product includes a protective plastic cover which shields exposed speaker components and prevents nicked wires. These devices enable faster installations by providing instant feedback to the Installer to ensure the following: • The wiring is properly connected. • The rotary switches are set to the selected voltage and power settings. • The 7 field-selectable candela settings are configured for wall speaker strobes. • The low total harmonic distortion of the SP speaker offers both high-fidelity and high-volume sound output so that it can be used in high ambient noise applications. L-Series makes installation easy to install the L-Series speakers or speaker strobe, do the following: 1. Attach a universal mounting plate to a 4 x 4 x 2 1/8 inch backbox. Flush- mount applications do not require an extension ring. 2. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. 3. To attach the speaker or speaker strobe to the mounting plate, insert the product tabs into the mounting plate grooves. 4. Hinge the device into position to lock the product pins into the mounting plate terminals. 5. A catch temporarily holds the device in place until you secure the device with a captured mounting screw. FEATURES & BENEFITS • Includes a plug-in feature and protective cover to reduce ground faults • Contains a universal mounting plate with an on-board shorting spring that is used to test the wiring continuity before an installation • No extension ring required • Field-selectable candela settings on ceiling units: - 15 - 30 - 75 - 95 - 115 - 150 - 177 • Uses an automatic selection of 12- or 24- volt operation at 15 and 30 candela • Provides a rotary switch that simplifies the field selection of speaker voltage (25) and 70.7 VRMS) and the following power settings: - 1/4 watt - 1/2 watt - 1 watt - 2 watts • Offers speakers with both high-fidelity and high-volume sound output • Compatible with the System Sensor synchronization protocol • Supports electrical compatibility with the existing SpectrAlert and the SpectrAlert Advance products •Designed with a tamper-resistant construction • Built with an updated modern design 2 L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General The L-Series speaker and speaker strobes shall mount to a 4 x 4 x 2 1/8-inch backbox. A universal mounting plate shall be used for the mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, the L-Series speaker strobes, when used with the Sync•Circuit. Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When these devices are used with the Sync•Circuit Module, either of the following may occur. • 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. The Indoor L-Series products shall operate between 32° F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have the following field-selectable candela settings: Speaker The speaker shall be an L-Series model _______ dual- voltage transformer speaker capable of operating at 25.0 or 70.7 nominal VRMS. It should be listed to UL Standard 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe Combination The speaker strobe shall be an L-Series model __________ listed to UL Standard 1480 and UL Standard 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal VRMS selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. UL Current Draw Data Table 1 lists the UL maximum strobe current draw. Table 2 lists the ceiling mount speaker sound outputs. Table 3 lists the ceiling-mount speaker strobe sound outputs. •15 •30 •75 •95 •115 •150 •177 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Table 1 UL Max. Strobe Current Draw (mA RMS) Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Table 2 Ceiling Speaker Sound Outputs Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 Table 3 Ceiling-Mount Speaker Strobe Sound Output 3 Dimensions Figure 1 shows the speaker dimensions. Figure 2 shows the speaker dimensions. Surface Mounting Figure 3 illustrates the ceiling-mount speaker and speaker strobes with the SBBCR/SBBCWL surface mount backbox. L-Series Ordering Information SpectrAlert Speakers and Strobes: Ceiling Mount: SPCWL: White Speaker only SPCRL: Red Speaker only SPSCWL: White Speaker Strobe SPSCRL: Red Speaker Strobe SPSCWL-P: Plain, Speaker Strobe SPSCWL-SP: Fuego, Speaker Strobe SPSCWL-CLR-ALERT : Alert, Speaker Strobe,Clear Lens Accessories: SBBCWL: White, Universal Ceiling Surface Mount Back Box SBBCRL: Red, Universal Ceiling Surface Mount Back Box TRC-2W: White, Universal Ceiling Trim Ring TRC-2: Red, Universal Ceiling Trim Ring Figure 1 Speaker Dimensions Figure 2 Speaker Dimensions Figure 3 Ceiling-Mount Speaker and Speaker Strobe with SBBCRL/SBBCWL Surface Mount Backbox L Series, Indoor Ceiling Strobes and Dual Speakers Technical Specifications 9021-60930 | C | 03/18 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s L Series, Indoor Ceiling Strobes and Dual Speakers and other products available by visiting www.Gamewell-FCI.com SYSTEM Electrical/Operating Specifications: Nominal Voltage (speakers): 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers): 50 VDC Strobe Flash Rate: 1 flash per second Nominal Voltage (strobes): Regulated 12 VDC or Regulated 24 VDC/FWR Operating Voltage Range (includes fire alarm panels with built-in sync): 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module: 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range: Frequency Range: 400 to 4,000 Hz Power: ¼, ½, 1, 2 watts STANDARDS The L-Series, Indoor Ceiling Strobes and Horn Strobes are designed to comply with the following standard: UL Standard: UL 1971 and UL 464 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S5512, S4011 CSFM: 7320-1653:0505 ISO 9001 Certification Physical Specifications: Operating Temperature:32°F to 120°F (0°C to 49°C) Humidity Range:10 to 93% non-condensing Dimensions,Ceiling-Mount:Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount BacKbox 6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Backbox 6.9 in, 176 mm 5.37 in,136 mm Calculations Protected Premises:Date:8/29/2023 Address: City:State:ID Zip:83440 Prepared Phone:801-468-8300 Address:Email: City:State:Utah Zip:84115 Secondary Load Requirements 10.79 Amp Hours Total (AH) 8.69 0.31 8.99 x 1.20 10.79 AH 18.00 Amp Hours Battery Distribution Chart Spare Battery Capacity 7.21 Amp Hours Secondary Standby Load 10.43 Amp Hours Secondary Alarm Load 0.37 Amp Hours 3.640 A x x Select batteries from the list bl Total Secondary Load System Power Requirements E3 Fire Alarm Control Panel with Broadband Battery Selection Secondary Standby Load 0.362 A Secondary Alarm Load 1481 S Major Street office@nelsonfire.com Salt Lake City 24 hours Required Standby Time Romney Building Remodel - BYU-I 281 S Center Street Rexburg Nelson Fire Systems Current Draw Time (hours) Total Secondary Load from the calculation table below. Shows amp-hour distribution of your selections. Derating factor Secondary Load Requirements 18 AH Battery (12 Volt Required Alarm Time (hours) 0.084 hours Spare Battery Capacity 40% Secondary Standby Load 58% Secondary Alarm Load 2%Spare Battery Capacity Secondary Standby Load Secondary Alarm Load 0.362 A 3.640 A Qty Draw Standby Qty Draw Alarm 0 x 0.08100 1 x 0.15000 0.15000 0 x 0.08100 0 x 0.15000 Intel. Loop Interface Main Board - Apollo (ILI95-MB-E3)0 x 0.05000 0 x 0.09100 Intel. Loop Interface Supplement Board - Apollo (ILI95-S-E3)0 x 0.05000 0 x 0.09100 E3 Panel, 1 SLC 0 x 0.05600 0 x 0.07600 E3 Panel, 1 SLC with DACT 0 x 0.07500 0 x 0.09500 1 x 0.06500 0.06500 1 x 0.08500 0.08500 0 x 0.08500 0 x 0.10500 120V Power Supply Sub-Assembly (PM-9)1 x 0.05000 0.05000 1 x 0.05000 0.05000 240V Power Supply Sub-Assembly (PM-9G)0 x 0.02700 0 x 0.05000 0 x 0.02400 1 x 0.02800 0.02800 0 x 0.01300 0 x 0.01300 0 x 0.01800 0 x 0.01800 0 x 0.05000 0 x 0.07500 0 x 0.20000 0 x 0.20000 1 x 0.01100 0.01100 1 x 0.01100 0.01100 0 x 0.01100 0 x 0.01100 0 x 0.06500 0 x 0.06500 Intelligent Network Inferface Module (INI-7100)0 x 0.04000 0 x 0.04000 0 x 0.02000 0 x 0.02000 0 x 0.03500 0 x 0.200000x0.00100 0 x 0.00100 0 x 0.00100 0 x 0.00100 0 x 0.15000 0 x 0.15000 0 x 0.01100 0 x 0.01100 0 x 0.00100 0 x 0.00100 0 x 0.02000 0 x 0.020000x0.00200 0 x 0.00650 1 x 0.15000 0.15000 1 x 0.15000 0.150000x0.05000 0 x 0.05000 240V Power Supply Sub-Assembly (PM-9G)0 x 0.02700 0 x 0.050001x0.08600 0.08600 1 x 2.20600 2.20600 Amplifier Sub-assembly, 50 watt 70V (AM-50-70)0 x 0.04900 0 x 2.300000x0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.15000 0 x 0.15000 0 x 0.01100 0 x 0.01100 0 x 0.00100 0 x 0.00100 0 x 0.02000 0 x 0.02000 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.00020 0 x 0.00200 0 x 0.00020 0 x 0.00200 0 x 0.00020 0 x 0.00200 0 x 0.00038 0 x 0.00500 0 x 0.00038 0 x 0.00650 0 x 0.00030 0 x 0.00700 0 x 0.00000 0 x 0.00000 12 x 0.00000 0.00000 12 x 0.08000 0.96000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 1 1 Device AMM-4F/AMM-2F AOM-2RF/AOM-2SF MS-7AF 8. Notification Appliances SPSCWL 1/2w Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Audio (AOM-MUX) ASD-PL3 7. Smoke Detectors/Modules ATD-RL3 DNR Firefighter's Telephone (Handset) Addressable Output Module-Signal (AOM-2SF) Intel. Network Voice Gateway (INI-VGX) 120V Power Supply Sub-Assembly (PM-9) Class A Option Module (CAOM) Municipal Circuit Option Module (MCOM) Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Audio (AOM-MUX) Voice Paging Microphone (Microphone) Firefighter's Telephone (Handset) 3. 7100 Optional Modules Intel. Network Command Voice Gateway (INI-VGE) Addressable Switch Sub-assembly (ASM-16) Voice Paging Microphone (Microphone) Network LCD Annunicator (NGA) Auxiliary Switch Sub-Assembly (ASM-16) 4. INI-VGC Command Center Intel. Network Command Center (INI-VGC) 6. INI-VGE Command Center Voice Gateway Addressable Switch Sub-assembly (ASM-16) Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Signal (AOM-2SF) 1. System Device E3 Panel, 2 SLC Amplifier Sub-assembly, 50 watt 25V (AM-50) 5. INI-VGX Voice Gateway LCD Display & Switch Control (LCD-E3) ARCNET Repeater (RPT-E3) Printer Transient Module (PTRM) Remote LED Driver Module (LDM-7100) Optional Remote Serial Annunicator (LCD-7100) Alarm CurrentStandby Current System Current Draw - FACP E3 Series Control Panel with Broadband Total AlarmTotal Standby Intel. Loop Interface, Main Board (ILI-MB-E3) Intel. Loop Interface Supplement Board (ILI-S-E3) Total Standby Load:0.362 A 3.640 ATotal Alarm Load: E3 Panel, 2 SLC with DACT 2. E3 Optional Modules Remote LED Driver Module (ANU-48) Addressable Node Expander (ANX) Digital Communicator (DACT-E3) Protected Premises:Date:2/27/2019 Address: City:State:ID Zip:83440 Prepared Phone:801-468-8300 Address:Email: City:State:Utah Zip:84115 Secondary Load Requirements 9.05 Amp Hours Total (AH) 7.50 0.04 7.55 x 1.20 9.05 AH 18.00 Amp Hours Battery Distribution Chart Spare Battery Capacity 8.95 Amp Hours Secondary Standby Load 9.01 Amp Hours Secondary Alarm Load 0.05 Amp Hours 0.488 A x x Select batteries from the list bl Total Secondary Load System Power Requirements E3 Fire Alarm Control Panel with Broadband Battery Selection Secondary Standby Load 0.313 A Secondary Alarm Load 1481 S Major Street office@nelsonfire.com Salt Lake City 24 hours Required Standby Time Romney Building Remodel - BYU-I 281 S Center Street Rexburg Nelson Fire Systems Current Draw Time (hours) Total Secondary Load from the calculation table below. Shows amp-hour distribution of your selections. Derating factor Secondary Load Requirements 18 AH Battery (12 Volt Required Alarm Time (hours) 0.084 hours Spare Battery Capacity 50% Secondary Standby Load 50% Secondary Alarm Load 0%Spare Battery Capacity Secondary Standby Load Secondary Alarm Load 0.313 A 0.488 A Qty Draw Standby Qty Draw Alarm 1 x 0.08100 0.08100 1 x 0.15000 0.15000 1 x 0.08100 0.08100 1 x 0.15000 0.15000 Intel. Loop Interface Main Board - Apollo (ILI95-MB-E3)0 x 0.05000 0 x 0.09100 Intel. Loop Interface Supplement Board - Apollo (ILI95-S-E3)0 x 0.05000 0 x 0.09100 E3 Panel, 1 SLC 0 x 0.05600 0 x 0.07600 E3 Panel, 1 SLC with DACT 0 x 0.07500 0 x 0.09500 1 x 0.06500 0.06500 1 x 0.08500 0.08500 0 x 0.08500 0 x 0.10500 120V Power Supply Sub-Assembly (PM-9)1 x 0.05000 0.05000 1 x 0.05000 0.05000 240V Power Supply Sub-Assembly (PM-9G)0 x 0.02700 0 x 0.05000 1 x 0.02400 0.02400 1 x 0.02800 0.02800 0 x 0.01300 0 x 0.01300 0 x 0.01800 0 x 0.01800 0 x 0.05000 0 x 0.07500 0 x 0.20000 0 x 0.20000 1 x 0.01100 0.01100 1 x 0.01100 0.01100 0 x 0.01100 0 x 0.01100 0 x 0.06500 0 x 0.06500 Intelligent Network Inferface Module (INI-7100)0 x 0.04000 0 x 0.04000 0 x 0.02000 0 x 0.02000 0 x 0.03500 0 x 0.200000x0.00100 0 x 0.00100 0 x 0.00100 0 x 0.00100 0 x 0.15000 0 x 0.15000 0 x 0.01100 0 x 0.01100 0 x 0.00100 0 x 0.00100 0 x 0.02000 0 x 0.020000x0.00200 0 x 0.00650 0 x 0.15000 0 x 0.150000x0.05000 0 x 0.05000 240V Power Supply Sub-Assembly (PM-9G)0 x 0.02700 0 x 0.050000x0.08600 0 x 2.20600 Amplifier Sub-assembly, 50 watt 70V (AM-50-70)0 x 0.04900 0 x 2.300000x0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.15000 0 x 0.15000 0 x 0.01100 0 x 0.01100 0 x 0.00100 0 x 0.00100 0 x 0.02000 0 x 0.02000 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.00200 0 x 0.00650 0 x 0.00020 0 x 0.00200 0 x 0.00020 0 x 0.00200 0 x 0.00020 0 x 0.00200 0 x 0.00038 0 x 0.00500 1 x 0.00038 0.00038 1 x 0.00650 0.00650 1 x 0.00030 0.00030 1 x 0.00700 0.00700 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 1 1 Device AMM-4F/AMM-2F AOM-2RF/AOM-2SF MS-7AF 8. Notification Appliances Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Audio (AOM-MUX) ASD-PL3 7. Smoke Detectors/Modules ATD-RL3 DNR Firefighter's Telephone (Handset) Addressable Output Module-Signal (AOM-2SF) Intel. Network Voice Gateway (INI-VGX) 120V Power Supply Sub-Assembly (PM-9) Class A Option Module (CAOM) Municipal Circuit Option Module (MCOM) Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Audio (AOM-MUX) Voice Paging Microphone (Microphone) Firefighter's Telephone (Handset) 3. 7100 Optional Modules Intel. Network Command Voice Gateway (INI-VGE) Addressable Switch Sub-assembly (ASM-16) Voice Paging Microphone (Microphone) Network LCD Annunicator (NGA) Auxiliary Switch Sub-Assembly (ASM-16) 4. INI-VGC Command Center Intel. Network Command Center (INI-VGC) 6. INI-VGE Command Center Voice Gateway Addressable Switch Sub-assembly (ASM-16) Addressable Output Module-Telephone (AOM-TEL) Addressable Output Module-Signal (AOM-2SF) 1. System Device E3 Panel, 2 SLC Amplifier Sub-assembly, 50 watt 25V (AM-50) 5. INI-VGX Voice Gateway LCD Display & Switch Control (LCD-E3) ARCNET Repeater (RPT-E3) Printer Transient Module (PTRM) Remote LED Driver Module (LDM-7100) Optional Remote Serial Annunicator (LCD-7100) Alarm CurrentStandby Current System Current Draw - FACP E3 Series Control Panel with Broadband Total AlarmTotal Standby Intel. Loop Interface, Main Board (ILI-MB-E3) Intel. Loop Interface Supplement Board (ILI-S-E3) Total Standby Load:0.313 A 0.488 ATotal Alarm Load: E3 Panel, 2 SLC with DACT 2. E3 Optional Modules Remote LED Driver Module (ANU-48) Addressable Node Expander (ANX) Digital Communicator (DACT-E3) Drawings ROMNEY 2023 REMODEL BRINGHAM YOUNG UNIVERSITY - IDAHO FIRE ALARM SYSTEM BH PAYNE TDT (ARCH C) 1/16" = 1' XXXX XXXX RO M N E Y 2 0 2 3 R E M O D E L BR I N G H A M Y O U N G U N I V E R S I T Y - I D A H O 28 1 S C E N T E R S T R E E T RE X B U R G , I D 8 3 4 4 0 FI R E A L A R M S Y S T E M PROJECT COVER SHEET FA-C-01 NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: ROMNEY REMODEL COVER.DWG 08/17/2023 INDEX OF DRAWINGS PAGE 1 2 3 4 5 6 FA-C-01 FA-R-01 FA-1-01 FA-1-02 FA-1-03 FA-2-01 SHEET #LEVEL PROJECT COVER SHEET / INDEX OF DRAWINGS FIRE ALARM BUILDING RISER DIAGRAM / MATRIX BASEMENT SECOND DEVICE SCHEDULE COUNTS MANUAL PULL STATION SPEAKER/STROBE- CEILING MULTI-VOLTAGE RELAY MS-7AF SPSCWL PR-1 DESCRIPTION FIRE/SMOKE DAMPER PROVIDED BY OTHERS F SS R FSD C 4 SQ. 2-1/8" DEEP BOX MINIMUM w/SINGLE GANG MUD RING 4 SQ. 2-1/8" DEEP BOX MINIMUM w/1-1/2" EXT. RING 4 SQ. 2-1/8" DEEP BOX MINIMUM PROVIDED BY OTHERS PART NUMBER MOUNTING REQUIREMENTSYMBOL 2 12 1 3 SUPERVISED CONTROL MODULE AOM-2SFCM 4 SQ. 2-1/8" DEEP BOX MINIMUM1 SHEET CONTENTS ADDRESSABLE CIRCUITS NOTIFICATION CIRCUITS ADDRESSABLE NUMBERS NOTIFICATION CIRCUITS BUILDING CONSTRUCTION TYPE: IIB BUILDING SQUARE FOOTAGE: 10,929 FT 2 BASEMENT BASEMENT BASEMENT DO NOT USE SHIELDED WIRE ON ADDRESSABLE CIRCUIT BH PAYNE TDT (ARCH C) 1/16" = 1' XXXX XXXX RO M N E Y 2 0 2 3 R E M O D E L BR I N G H A M Y O U N G U N I V E R S I T Y - I D A H O FI R E A L A R M R I S E R D I A G R A M / M A T R I X 28 1 S C E N T E R S T R E E T RE X B U R G , I D 8 3 4 4 0 FI R E A L A R M S Y S T E M FIRE RISER DIAGRAM / MATRIX FA-R-01 NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: ROMNEY REMODEL RISER.DWG 08/17/2023 FACU (EXISTING) (EXISTING) BATTERY CABINET LOCATED IN MECHANICAL ROOM 10 TRANSPONDER (EXISTING) LEVEL 2 EXISTING ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED NEW ADDRESSABLE CIRCUIT 1/2W 1/2W SP1-1 1/2W 1/2W SP1-2 1/2W SP1-3 1/2W SP1-4 1/2W SP1-5 SP1-7SP1-6 1/2W SP1-8 1/2W 1/2W SP1-9 1/2W SP1-10 SP1-11 1 PAIR #14'S TWISTED SHIELDED SPEAKER CIRCUIT L1-1 15cd L1-2 95cd L1-3 15cd L1-4 75cd L1-5 15cd L1-6 15cd L1-7 15cd L1-8 15cd L1-9 95cd L1-10 75cd L1-11 15cd (1) STROBE CIRCUIT 2 #14'S SS C SS C SS C SS C SS C SS C SS C SS C SS C SS CSSC SP2-1 1/2W L2-1 75cd SS C BASEMENT LEVEL- SMOKE DETECTORS BASEMENT LEVEL- DUCT DETECTORS BASEMENT LEVEL- PULL STATIONS SECOND LEVEL- SMOKE DETECTORS SECOND LEVEL- DUCT DETECTORS SECOND LEVEL- PULL STATIONS LOSS OF POWER ANY PANEL OR NAC LOW BATTERY CONDITIONS OPEN CIRCUIT CONDITIONS GROUND FAULTS AL A R M S I G N A L T O F I R E A L A R M D I S P L A Y SU P E R V I S O R Y S I G N A L T O F I R E A L A R M D I S P L A Y TR O U B L E S I G N A L T O F I R E A L A R M D I S P L A Y BU I L D I N G S P E A K E R / S T R O B E S HV A C S H U T - D O W N FI R E / S M O K E D A M P E R S RE L E A S E M A G N E T I C D O O R H O L D E R S AL A R M S I G N A L T O M O N I T O R I N G C O M P A N Y SU P E R V I S O R Y S I G N A L T O M O N I T O R I N G C O M P A N Y TR O U B L E S I G N A L T O M O N I T O R I N G C O M P A N Y FACP ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL REPORTING SYSTEM INPUTS SYSTEM OUTPUTSFIRE ALARM INPUT/OUTPUT MATRIX WIRING NOTES: - THREE AND A HALF TWISTS PER FOOT MINIMUM - DO NOT USE SHIELDED WIRE ON ADDRESSABLE CIRCUITS 1 FOOT F F CM R 120 VAC W/GROUND FSD FSD FSD [MS-7AF] MANUAL PULL STATION ADDRESSABLE CKT 1 2 3 4 FIRE PUSH IN PULL DOWN IN (+) (-)TO NEXT DEVICEOUT(+) (-) [AOM-2SF] w/[PR-3] CONTROL MODULE w/RELAY - + BLACK RED N/C YELLOW N/O ORANGE COMMON BLUE FIELD DEVICE NEUTRALHOT NEUTRAL- HOT + BLACK RED FIELD DEVICE NEUTRALHOT (-) (+) (+) (-) 24 V D C A U X P O W E R W/ GROUND 120 VACPR-3 (+) (-) (+) (-) slc(+) ext pwr (+) ext pwr (-) slc(-) AOM-2SF (-) (+) (+) (-) AD D R E S S A B L E C K T F PULL STATION R RELAY 2 1 FSD FIRE/SMOKE DAMPER3 CM CONTROL MODULE SUPERVISED1 SS SPEAKER/STROBE- CEILING12C DEVICE LEGEND DESCRIPTIONCOUNTSSYMBOL L1M001 N27 N27 N27 L1M002 L1M090 [SPSCWL] CEILING SPEAKER STROBE TO NEXT DEVICESPEAKER CKT OUTIN TO NEXT DEVICE(+) (-)STROBE CIRCUIT IN OUT(+) (-) DRAIN WIRE (MUST NOT BE GROUNDED) 2 #14'S 24 AUX POWER EXISTING SPEAKER/STROBE CIRCUIT 2 PAIR #14'S TWISTED SHIELDED (2) NEW SPEAKER CIRCUITS (2) NEW STROBE CIRCUITS 4 #14'S SS (E) 4.7K EOL 3.9K SS EXISTING SPEAKER/STROBE1(E) LOCATED ON SECOND FLOOR TRANSPONDER (EXISTING) BH PAYNE TDT (ARCH C) 1/16" = 1' XXXX XXXX RO M N E Y 2 0 2 3 R E M O D E L BR I N G H A M Y O U N G U N I V E R S I T Y - I D A H O 28 1 S C E N T E R S T R E E T RE X B U R G , I D 8 3 4 4 0 FI R E A L A R M S Y S T E M BASEMENT ADDRESSABLE FA-1-01 25'10'50' W E S N NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: 801-468-8300 ROMNEY REMODEL B DRAWING.DWG 08/17/2023 1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. CLASS "B" WIRING IS REQUIRED. 2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITION ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER CABLES ARE IN THE RACEWAY. 3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT. FURTHERMORE, ALL PL AND NPL CKT WIRING MUST ENTER AND EXIT THE CABINET THROUGH A DIFFERENT KNOCKOUT AND/OR SEPARATE CONDUIT. 4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT. 5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS. 8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT OR POWER SUPPLY. 9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. 10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. GENERAL NOTES: WIRE SCHEDULE NOTE DESCRIPTION WIRES A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED P 24 VDC AUX POWER 2 #14'S S L SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED STROBE CIRCUIT 3 #12'S WIRING NOTE DESCRIPTION A =2 TOTAL CONDUCTORS (2)A =4 TOTAL CONDUCTORS A,(2)B =6 TOTAL CONDUCTORS F PULL STATION R RELAY TRAN EXISTING TRANSPONDER PANEL 2 1 1 FSD FIRE/SMOKE DAMPER3 CM CONTROL MODULE SUPERVISED1 SS SPEAKER/STROBE- CEILINGC DEVICE LEGEND DESCRIPTIONCOUNTSSYMBOL SYSTEM NOTES: 1 2 3 MAINTAIN EXISTING CIRCUITING TO NEW DEVICE 120 VAC w/GROUND TO RELAY FOR FIRE/SMOKE DAMPERS PIPE CHASE O-B MEN'S RM 66 WOMEN'S RM 64 63 STAIRWELL O-Q COMPACT FILL PLANRTARIUM RM 107 LIGHT TRAP I-Y STORAGE 18 CUST OFFICE 16 CUSTODIAL LAUNDRY 14 MECHANICAL ROOM 69 MECHANICAL RM 10 VESTIBULE O-A MECH RM 12 HALLWAY O-C STORAGE ELEVATOR O-D MECH RM 67 CUST RM 68 STAIRWELL 0-F STORAGE 20 ELEVATOR 0-K ELEC VAULT 80 COMPACT FILL COMPACT FILL CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PI P E TU N N E L HALLWAY 0-N CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PIPE TUNNEL COMPACT FILL EXTERIOR MECHANICAL ENCLOSURE DARK ROOM 59D COMPUTER LAB 59 PHOTO STUDIO 51 VESTIBULE 59C OFFICE 57 EQUIP / CHECK OUT 59A STORAGE 59B OFFICE 55 FILM 59E ACOUSTICS STUDIO 52B STORAGE 51A CHANGING 51B VESTIBULE 0-H OPTICS LAB 52A PHYSICS LAB 52 STORAGE 52C CLASSROOM 50 FACU (E) F F FSD FSD FSD CM R (E) 3 F 1 1 F 120 VAC POWER 2 #14'S F F F (2)A,(2)P TO EXISTING TRANSPONDER LOCATED IN MECHANICAL ROOM 10 BASEMENT SS EXISTING SPEAKER/STROBE- WALL (E) BH PAYNE TDT (ARCH C) 1/16" = 1' XXXX XXXX RO M N E Y 2 0 2 3 R E M O D E L BR I N G H A M Y O U N G U N I V E R S I T Y - I D A H O 28 1 S C E N T E R S T R E E T RE X B U R G , I D 8 3 4 4 0 FI R E A L A R M S Y S T E M BASEMENT NOTIFICATION FA-1-02 25'10'50' W E S N NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: 801-468-8300 ROMNEY REMODEL B DRAWING.DWG 08/17/2023 1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. CLASS "B" WIRING IS REQUIRED. 2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITION ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER CABLES ARE IN THE RACEWAY. 3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT. FURTHERMORE, ALL PL AND NPL CKT WIRING MUST ENTER AND EXIT THE CABINET THROUGH A DIFFERENT KNOCKOUT AND/OR SEPARATE CONDUIT. 4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT. 5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS. 8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT OR POWER SUPPLY. 9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. 10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. GENERAL NOTES: WIRE SCHEDULE NOTE DESCRIPTION WIRES A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED P 24 VDC AUX POWER 2 #14'S S L SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED STROBE CIRCUIT 3 #12'S WIRING NOTE DESCRIPTION A =2 TOTAL CONDUCTORS (2)A =4 TOTAL CONDUCTORS A,(2)B =6 TOTAL CONDUCTORS F PULL STATION R RELAY TRAN EXISTING TRANSPONDER PANEL1 FSD FIRE/SMOKE DAMPER CM CONTROL MODULE SUPERVISED SS SPEAKER/STROBE- CEILING11C DEVICE LEGEND DESCRIPTIONCOUNTSSYMBOL SYSTEM NOTES: 1 2 3 MAINTAIN EXISTING CIRCUITING TO NEW DEVICE 120 VAC w/GROUND TO RELAY FOR FIRE/SMOKE DAMPERS PIPE CHASE O-B MEN'S RM 66 WOMEN'S RM 64 63 STAIRWELL O-Q COMPACT FILL PLANRTARIUM RM 107 LIGHT TRAP I-Y STORAGE 18 CUST OFFICE 16 CUSTODIAL LAUNDRY 14 MECHANICAL ROOM 69 MECHANICAL RM 10 VESTIBULE O-A MECH RM 12 HALLWAY O-C STORAGE ELEVATOR O-D MECH RM 67 CUST RM 68 STAIRWELL 0-F STORAGE 20 ELEVATOR 0-K ELEC VAULT 80 COMPACT FILL COMPACT FILL CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PI P E TU N N E L HALLWAY 0-N CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PIPE TUNNEL COMPACT FILL EXTERIOR MECHANICAL ENCLOSURE DARK ROOM 59D COMPUTER LAB 59 PHOTO STUDIO 51 VESTIBULE 59C OFFICE 57 EQUIP / CHECK OUT 59A STORAGE 59B OFFICE 55 FILM 59E ACOUSTICS STUDIO 52B STORAGE 51A CHANGING 51B VESTIBULE 0-H OPTICS LAB 52A PHYSICS LAB 52 STORAGE 52C CLASSROOM 50 FACU (E) SP1-8 1/2W L1-8 15cd SS C SP1-9 1/2W L1-9 95cd SS C SP1-4 1/2W L1-4 75cd SS C SP1-3 1/2W L1-3 15cd SS C SP1-2 1/2W L1-2 95cd SS C SP1-1 1/2W L1-1 15cd SS C SP1-11 1/2W L1-11 15cd SS C SP1-6 1/2W L1-6 15cd SS C SP1-7 1/2W L1-7 15cd SS C SP1-5 1/2W L1-5 15cd SS C SP1-10 1/2W L1-10 75cd SS C 2 S,L (E) EOL 4.7K 3.9K F 120 VAC POWER 2 #14'S TO EXISTING TRANSPONDER LOCATED IN MECHANICAL ROOM 10 BASEMENT SS (E)SS (E) SS EXISTING SPEAKER/STROBE- WALL (E) BH PAYNE TDT (ARCH C) 1/16" = 1' XXXX XXXX RO M N E Y 2 0 2 3 R E M O D E L BR I N G H A M Y O U N G U N I V E R S I T Y - I D A H O 28 1 S C E N T E R S T R E E T RE X B U R G , I D 8 3 4 4 0 FI R E A L A R M S Y S T E M BASEMENT 25'10'50' W E S N NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: 801-468-8300 ROMNEY REMODEL B DRAWING.DWG 08/17/2023 1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. CLASS "B" WIRING IS REQUIRED. 2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITION ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER CABLES ARE IN THE RACEWAY. 3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT. FURTHERMORE, ALL PL AND NPL CKT WIRING MUST ENTER AND EXIT THE CABINET THROUGH A DIFFERENT KNOCKOUT AND/OR SEPARATE CONDUIT. 4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT. 5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS. 8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT OR POWER SUPPLY. 9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. 10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. GENERAL NOTES: WIRE SCHEDULE NOTE DESCRIPTION WIRES A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED P 24 VDC AUX POWER 2 #14'S S L SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED STROBE CIRCUIT 3 #12'S WIRING NOTE DESCRIPTION A =2 TOTAL CONDUCTORS (2)A =4 TOTAL CONDUCTORS A,(2)B =6 TOTAL CONDUCTORS F PULL STATION R RELAY TRAN EXISTING TRANSPONDER PANEL 2 1 FSD FIRE/SMOKE DAMPER CM CONTROL MODULE SUPERVISED1 SS SPEAKER/STROBE- CEILINGC DEVICE LEGEND DESCRIPTIONCOUNTSSYMBOL SYSTEM NOTES: 1 2 3 MAINTAIN EXISTING CIRCUITING TO NEW DEVICE 120 VAC w/GROUND TO RELAY FOR FIRE/SMOKE DAMPERS PIPE CHASE O-B MEN'S RM 66 WOMEN'S RM 64 63 STAIRWELL O-Q COMPACT FILL PLANRTARIUM RM 107 LIGHT TRAP I-Y STORAGE 18 CUST OFFICE 16 CUSTODIAL LAUNDRY 14 MECHANICAL ROOM 69 MECHANICAL RM 10 VESTIBULE O-A MECH RM 12 HALLWAY O-C STORAGE ELEVATOR O-D MECH RM 67 CUST RM 68 STAIRWELL 0-F STORAGE 20 ELEVATOR 0-K ELEC VAULT 80 COMPACT FILL COMPACT FILL CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PI P E TU N N E L HALLWAY 0-N CRAWL SPACE PIPE TUNNEL PIPE TUNNEL PIPE TUNNEL COMPACT FILL EXTERIOR MECHANICAL ENCLOSURE DARK ROOM 59D COMPUTER LAB 59 PHOTO STUDIO 51 VESTIBULE 59C OFFICE 57 EQUIP / CHECK OUT 59A STORAGE 59B OFFICE 55 FILM 59E ACOUSTICS STUDIO 52B STORAGE 51A CHANGING 51B VESTIBULE 0-H OPTICS LAB 52A PHYSICS LAB 52 STORAGE 52C CLASSROOM 50 FACU (E) F L1M002 N27 F L1M001 N27 CM L1M090 N27 (E) F 120 VAC POWER 2 #14'S NUMBERS FA-1-03 TO EXISTING TRANSPONDER LOCATED IN MECHANICAL ROOM 10 BASEMENT SS EXISTING SPEAKER/STROBE- WALL (E) BH PAYNE TDT (ARCH C) 1/16" = 1' XXXX XXXX RO M N E Y 2 0 2 3 R E M O D E L BR I N G H A M Y O U N G U N I V E R S I T Y - I D A H O 28 1 S C E N T E R S T R E E T RE X B U R G , I D 8 3 4 4 0 FI R E A L A R M S Y S T E M LEVEL 2 NOTIFICATION FA-2-01 25'10'50' W E S N NELSON FIRE SYSTEMS DRAWN BY: DESIGNED BY: APPROVED BY: DATE: SCALE: PROJECT NO: REVISION NO: DRAWING NAME: NO T E : NF S D R A W I N G S A R E B A S E D O N T H E P R O J E C T AR C H I T E C T U R E / E N G I N E E R ( A / E ) P L A N S A N D SP E C I F I C A T I O N S F U R N I S H E D T O N F S . A / E I S S O L E L Y RE S P O N S I B L E ( N O T N F S ) F O R T H E T Y P E , S I Z E , LO C A T I O N , A N D S U I T A B I L I T Y O F A L L F I R E A L A R M S , CO N T R O L P A N E L S , A N D O T H E R D E V I C E S S H O W N O N TH E A / E P L A N S . N F S D R A W I N G S A R E T O S H O W O N L Y TH E W I R I N G D I A G R A M S B E T W E E N F I R E A L A R M DE V I C E S A N D C O N T R O L P A N E L S . N F S I S N O T RE S P O N S I B L E F O R T H E I N F O R M A T I O N S H O W N O N T H E A/ E P L A N S . NELSON FIRE SYSTEMS PAGE: 801-468-8300 ROMNEY REMODEL 2 DRAWING.DWG 08/17/2023 1.INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AHJ. CLASS "B" WIRING IS REQUIRED. 2.WIRING DEPICTED ON THESE PLAN IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITION ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER CABLES ARE IN THE RACEWAY. 3.POWER-LIMITED (PL) AND NONPOWER-LIMITED (NPL) CKT WIRING MUST REMAIN SEPARATED IN CABINET. ALL PL CKT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NPL CKT. FURTHERMORE, ALL PL AND NPL CKT WIRING MUST ENTER AND EXIT THE CABINET THROUGH A DIFFERENT KNOCKOUT AND/OR SEPARATE CONDUIT. 4.ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. DO NOT USE 110V OR HIGHER IN FIRE ALARM CONDUIT. 5.SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 6.LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 7.DO NOT USE SHIELDED WIRE ON ADDRESSABLE CKTS. 8.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A FIRE ALARM CONTROL UNIT OR POWER SUPPLY. 9.FIRE ALARM CKTS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. 10.DEDICATED 120 VAC CKTS SHALL BE MARKED AS "FIRE ALARM CKT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CKTS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. GENERAL NOTES: SS SPEAKER/STROBE- CEILING1C DEVICE LEGEND DESCRIPTIONCOUNTSSYMBOL SYSTEM NOTES: 1 2 3 TIE INTO NEAREST ADDRESSABLE DEVICE TIE INTO NEAREST EXISTING NOTIFICATION DEVICE 120 VAC w/GROUND TO RELAY FOR FIRE/SMOKE DAMPERS INSTRUMENT RM 203A CHEMISTRY STOCK RM 213 OFFICE 213A CLASSROOM 270 CLASSROOM 268 MEN'S RM 266 WOMEN'S RM 264 OFFICE 252 OFFICE 253 OFFICE 250 OFFICE 248 OFFICE 246 OFFICE 244 OFFICE 242 OFFICE 240 OFFICE 238 WORK ROOM 243 OFFICE 236 OFFICE 234 OFFICE 239 OFFICE 237 OFFICE 235 OFFICE 233 OFFICE 232 CLASSROOM 255 CLASSROOM 277 OFFICE 259 OFFICE 261 OFFICE 263 OFFICE 265 MEN'S ROOM 226 WOMEN'S ROOM 220 GENERAL CHEM LAB 282 CHEM STOCK RM 282A OFFICE 286 OFFICE 285 OFFICE 289 OFFICE 290 OFFICE 291 OFFICE 292 OFFICE 294 OFFICE 296 OFFICE 298 CHEMISTRY LAB 204 CHEMISTRY LAB 214 CHEMISTRY LAB210 CHEMISTRY PREP RM281 CLASSROOM 276 CUST RM 267 BDF RM 280 CUST RM 228 INSTRUMENT RM 203B CLASSROOM 229 CLASSROOM 279 CLASSROOM 297 CLASSROOM 299 CHEMISTRY LAB203 STORAGE 258 STORAGE RM 277A WORK ROOM 287A SEC/ RECEP RM 287 HALLWAY 2-U HALLWAY 2-D HALLWAY 2-F HALLWAY 2-S LOUNGE 2-V HALLWAY 2-J HALLWAY 2-M SECRETARY/RECEPTION RM 230 HALLWAY 2-K CLASSROOM 260 CLASSROOM 262 HALLWAY 2-L CUST STOR 216 STAIRWELL 2-HELEVATOR 2-G STAIRWELL 2-T HALLWAY 2-B STAIRWELL 2-A STAIRWELL 2-C 1,553 SF BIO-CHEMISTRY LAB 272 SP2-1 1/2W L2-1 75cd SS C (2)S,(2)L WIRE SCHEDULE NOTE DESCRIPTION WIRES A ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED P 24 VDC AUX POWER 2 #14'S S L SPEAKER CIRCUIT 1 PAIR #14'S TWISTED/SHIELDED STROBE CIRCUIT 2 #14'S WIRING NOTE DESCRIPTION A =2 TOTAL CONDUCTORS (2)A =4 TOTAL CONDUCTORS A,(2)B =6 TOTAL CONDUCTORS F 120 VAC POWER 3 #12'S SS(E) SS EXISTING SPEAKER/STROBE- WALL1(E) LEVEL 2