HomeMy WebLinkAboutBOLT REPORT 2 - 22-00611 - EVO Automation - New CommercialInspection Details
Date Contractor Inspector Weather Permit Number
02/03/2023 Silverline Builders Clark, Josh Sunny na
Project Specifications:
Snug Tight only
Full Tension/Slip Critical
Full Tension/Slip Critical:
TurnoftheNut method
Calibrated Wrench method
Direct Tension Indicators LoadIndicating Washers
Direct Tension Indicators TwistOffBolts (”Lejune” bolts)
Bolt Type:
ASTM A325
ASTM A490 Other
Bolt Type Other:
Bolt size
Diameter Length
varied varied
Washer Specifications:
Hardened washers
Plate washers
None required
General Conditions
Faying surfaces flush and in full contact
Faying surfaces free from paint, oil, etc.
Visually monitored turnofthenut method
Verified Installation equipment and bolts using Skidmore
Wilhelm tension measuring device
Visually Inspected twistoff bolts
Washers at slotted holes under turned element
Verified a minimum of 2 bolts per connection or 10% of all
bolts
Reference Drawing Sheet and Detail, and Approved RFI:general structural notes
Location(s):rigid frame lines
Notes:
snugtight verified. additional 1/3 of turn to be accomplished at a later date. contractor will reschedule to verify final rotation has been
completed
Work inspected was:
in compliance in compliance, except as noted in comments section reinspection/retesting required
Note: The recording of false, fictitious, or fraudulent statements or entries on this document may be punishable as a felony under
Federal Statute.
✔
✔
✔
✔
✔
✔
✔
High Strength Bolting Report 02/07/2023Report Date:
Atlas Technical Consultants, LLC Idaho
Falls
1753 E Precision Drive
Idaho Falls, ID 83402
Phone: (208) 5298242
Client:
Silverline Builders
1052 West 14 North
Rexburg, ID 83440
Project:
E230205c
EVO Automation, 2557 South Frontage Road,
Rexburg, ID
2557 South Frontage Road
Rexburg, ID
NOTICE: Our firm’s professionals are represented on site solely to observe operations of the contractor identified,
to form opinions about the adequacy of those operations, and to report those opinions to our client. The presence
and activities of our field representatives do not relieve any contractor from its obligation to meet contractual
requirements. No one except our client may rely on our findings and opinions. The contractor retains sole
responsibility for site safety and the methods, operations, and sequences of construction.