HomeMy WebLinkAboutCODE REVIEW - 22-00611 - EVO Automation - New CommercialMAIN FLOOR PLAN
SCALE: 1 /8"=V-Q"
GODS REV I EVV
OCCUPANCY TYPE: 5-2, B NON -SPRINKLED, NON -SEPARATED
CONSTRUCTION TYPE: TYPE I I I -B
ALLOWABLE HEIGHT/STORIES: 40' / 2 STORI E5
ACTUAL HEIGHT/STORIES: 55, / 2 STORIES
OCCUPANCY: 5-2: 50
51. 55 (Icl MAIN, Iq UPPER)
TOTAL: 6ci OCCUPANTS
TABLE 1006.2.1: SPACES WITH I EXIT
I EXIT: MAX. OCCUPANTS 201, MAX COMMON PATH OF EGRESS: 100'
TABLE 1006.5.5: (2) STORIES WITH I EXIT
GRADE LEVEL: MAX. OCCUPANCY: 241, MAX. COMMON PATH OF EGRESS: -75'
SECOND LEVEL: MAX. OCCUPANCY: 261, MAX. COMMON PATH OF EGRESS: 15'
TABLE 101 '7.2 : EXIT TRAVEL D 1 STANCE
5-2: 500 L.F. > I411 L.F. = PASS
EMERGENCY EXIT SIGN WITH EGRESS LIGHTING
AND DIRECTIONAL ARROWS A5 SHOWN
FEG FIRE EXTINGUISHER 4 FIRE EXTINGUISHER CABINET
NET
SECOND FLOOR PLAN
SCALE: 1 /8"=1'-O"
0
tZ
m
O
w
Q
F-
U
H
U
a
w
_
O
Z
W
N
Z
O
U
z
w
Of
O
_
3
V)
Q
w
0
Of
O
V)
Z
0
V)
w
0
vi
0
Z
Q
0
O
w
V)
D
0
w
N_
Of
O
_
D
Q
Z
Z
Q
J
O
Of
H
Z
O
U
0
Z
Q
d
2
V)
Of
W
Z
O
J
a
O
U)
z
w
Of
U
w
H
2
U
Of
a
w
0
z
a
_
0
r
a
O
U
m
0
w
H
U
Ld
H
O
Of
0-
w
Of
a
V)
z
c�
V)
w
0
0
z
Q
c�
z
Q
Of
0
C.>
J
J
N
W
a
U
O
a
JRW & Associates, PLLC has provided life
safety code review only. No review of
construction documents for constructibility,
zoning compliance, placement on site, etc.
have been performed.
BR ENT A. McFARLAND
AR-2561
10/05/2022
STATE OF IDAHO
V) rX
Wo_
Q
0
Q�
m
x
w
Ua
c'n
0�
w
z
Q
0
0
m
Q z
(V
CONSULTANTS:
A
O
O
O
F
w
z
O
a
o
REVISION:
DRAWN BY:
JOB NO:
BAM
ci25
CHECKED BY.
DATE:
BALM
SEPT. 122
PLOT DATE: 10-03-22
DRAWING NO.
FILE: 925 CODE REVIEW * G1.1
G1.1
OF 1