Loading...
HomeMy WebLinkAboutREDLINED FA PLANS - 22-00269 - Hibbard Elementary SchoolAuthor Name Author Email Author Phone No.: Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : 2335 N 3000 W - Hibbard Elementary School Address : 2335 N 3000 W Application Type : Document Filename : Hibbard Elementary FA Submittal Drawings 06-10-23.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments FA-10 Callout Alex Owens : Electrical Open 2 Signaling device needed in restroom area. FA-10 Callout Alex Owens : Electrical Open 2 As per NFPA 72 17.14.8.4 and 5 a manual fire alarm box shall be located within 5 feet of each exit doorway each floor and every 200 feet down a corridor. FA-50 Free Text Alex Owens : Electrical Open 12 Please provide cut sheets for the devices/equipment to be used. # 22-00269 Madison County - Commercial Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 07.10.2023 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) DEVICE LEGEND SYMBOL QTY MANUFACTURER PART NO DESCRIPTION SIZE 2 GENERIC VALVE TAMPER SUPERVISORY SWITCH BY OTHERS 1 SILENT KNIGHT 6820EVS INTELLIGENT FIRE ALARM CONTROL PANEL WITH COMMUNICATOR W/EMERGENCY VOICE SYSTEM PROVIDED BY TETON SMART SECURITY 2 SILENT KNIGHT SK-PS10 10.0 A, 120 VAC REMOTE CHARGER POWER SUPPLY IN A LOCKABLE, METAL ENCLOSURE PROVIDED BY TETON SMART SECURITY 1 SILENT KNIGHT 6860 REMOTE ANNUNCIATOR, RED FLUSH MOUNT: OUTSIDE WALL: 12.25”W X 11.05”H X .875”D (31.01W X 29.02H X 2.02D CM) INSIDE WALL: 9.375”W X 8.375”H X 2.0”D (23.08W X 21.03H X 5.01D CM) SURFACE MOUNT: (INCLUDING TRIM RING) 12.25”W X 11.05”H X 3.0”D (31.01W X 29.02H X 2.02D CM) 1 SILENT KNIGHT EVS-100W PANEL COMPONENT, INTELLIGENT 50/100 WATT AMPLIFIER PROVIDED 11 SYSTEM SENSOR RTS151KEY REMOTE TEST STATION W/ SWITCH, ALARM & POWER LEDS, KEY RESET SINGLE GANG 2 GENERIC WATERFLOW SWITCH BY OTHERS 1 SILENT KNIGHT SK-PULL-DA SINGLE ACTION PULL STATION SINGLE GANG 8 SILENT KNIGHT SK-MONITOR MONITOR MODULE 4' SQ. DEEP 1 SILENT KNIGHT SK-CONTROL NOTIFICATION MODULE 4' SQ. DEEP 14 SILENT KNIGHT SK-RELAY RELAY MODULE 4' SQ. DEEP 11 SILENT KNIGHT SK-DUCT-W W/SK-PHOTO-R-W INTELLIGENT NON-RELAY PHOTOELECTRIC LOW FLOW SMOKE DETECTOR HOUSING W/ DETECTOR N/A 1 SILENT KNIGHT SK-HEAT-W W/B300-6 WHITE, LOW-PROFILE INTELLIGENT 135°F FIXED THERMAL SENSOR, W/STANDARD BASE 4' SQ. DEEP 25 SILENT KNIGHT SK-PHOTO-W W/B300-6 WHITE, LOW-PROFILE PHOTOELECTRIC SENSOR W/BASE 4' SQ. DEEP 5 SYSTEM SENSOR P2RK 2-WIRE HORN STROBE, STANDARD CD, OUTDOOR 4' SQ. DEEP 3 SYSTEM SENSOR SPSRL SPEAKER/STROBE WALL MOUNT, RED 4" x 4" x 2 1 8" DEEP 113 SYSTEM SENSOR SPSCWL SPEAKER/STROBE CEILING MOUNT, WHITE 4" x 4" x 2 1 8" DEEP 13 SYSTEM SENSOR SRL STROBE, RED 4" x 4" x 1 1 2" DEEP 11 SYSTEM SENSOR FM998 24V DOOR HOLDER SINGLE GANG 1 DITEK DTK-120HW 120VAC 54KA PARALLEL CONNECTED SURGE PROTECTIVE DEVICE FACU NAC FAA AMP F AIM AOM AOM S H 135 FT S WP DH SS SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 SYSTEM SEQUENCE OF OPERATIONS PROJECT DIRECTORY APPLICABLE CODES & STANDARDS ABBREVIATIONS LEGEND GENERAL NOTES LEGENDSDRAWING INDEX DEVICE TAG LEGEND SCOPE OF WORK FIRE ALARM SYSTEM SCHOOL HIBBARD ELEMENTARY Site HIBBARD ELEMENTARY REXBURG, IDAHO PROVIDE AND INSTALL A NEW AUTOMATIC AND MANUAL FIRE ALARM SYSTEM AS SHOWN ON DRAWINGS. ALL WIRING TO BE CLASS B NOTIFICATION APPLIANCE CIRCUITS, INITIATING DEVICE CIRCUITS, AND SIGNALING LINE CIRCUITS. AUTOMATIC FIRE ALARM SYSTEM SHALL TRANSMIT THE ALARM, SUPERVISORY AND TROUBLE SIGNALS TO AN APPROVED SUPERVISING STATION. THE SUPERVISING STATION SHALL BE LISTED AS EITHER UUFX OR UUJS UNDERWRITERS LABORATORY OR SHALL MEET THE REQUIREMENTS OF FACTORY MUTUAL RESEARCH APPROVAL STANDARD 3011. SUPERVISION OF SYSTEM AND LEASED TELEPHONE LINES SHALL BE ARRANGED BY THE OWNER. OCCUPANCY TYPE(S):SPRINKLER PROTECTION: E EDUCATIONAL GROUP BUILDING IS FULLY SPRINKLERED JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. International Building Code (IBC), 2018 Edition International Fire Code (IFC), 2018 Edition National Electric Code (NFPA 70), 2017 Edition National Fire Alarm Code (NFPA 72), 2019 Edition AC =ABOVE CEILING AFF =ABOVE FINISHED FLOOR AHJ =AUTHORITY HAVING JURISDICTION ALM =ALARM ANN =ANNUNCIATOR BMS =BUILDING MANAGEMENT SYSTEM C =CEILING MOUNTED CD =CANDELA RATING DET =DETECTOR DGP =DATA GATHERING PANEL E =EXISTING TO REMAIN EOL =END OF LINE EPO =EMERGENCY POWER OFF ER =ELEVATOR RECALL FAA =FIRE ALARM ANNUNCIATOR FACP =FIRE ALARM CONTROL PANEL FATC =FIRE ALARM TERMINAL CABINET FBO =FURNISHED BY OTHERS FCC =FIRE COMMAND CENTER FSD =FIRE SMOKE DAMPER FTR =FIRE ALARM TRANSPONDER H =HIGH HUMIDITY HT =HEIGHT HVAC =HEATING VENTILATION & AIR CONDITIONING IMS =INFORMATION MANAGEMENT SYSTEM MAX =MAXIMUM MIN =MINIMUM N/A =NOT APPLICABLE NAC =NOTIFICATION APPLIANCE CIRCUIT NDU =NETWORK DISPLAY UNIT NEC =NATIONAL ELECTRIC CODE NFPA =NATIONAL FIRE PROTECTION ASSOCIATION NIC =NOT IN CONTRACT NPU =NETWORK PROCESSING UNIT NTS =NOT TO SCALE PAP =PRE-ACTION PANEL RC =EXISTING TO REMOVE AND COVER RD =EXISTING DEVICE TO BE RELOCATED RL =RELOCATED DEVICE RR =REMOVE EXISTING & REPLACE WITH NEW SCC =STATUS COMMAND CENTER SLC =SIGNALING LINE CIRCUIT SMK =SMOKE SUPV =SUPERVISORY TAC =TRUEALERT ADDRESSABLE CONTROLLER TOS =TOP OF SHAFT TRBL =TROUBLE TS =TAMPER SWITCH TYP =TYPICAL UON =UNLESS OTHERWISE NOTED VCC =VOICE COMMAND CENTER VT =VALVE TAMPER W =WATTAGE W/=WITH W/O =WITHOUT WF =WATERFLOW WG =WIRE GUARD WP =WEATHERPROOF XP =EXPLOSION PROOF TETON SMART SECURITY CONTACTS MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-001 COVER SHEET HI B B A R D E L E M E N T A R Y SC H O O L DEVICE DESIGNATOR P1:V2-1 VISUAL, AUDIBLE OR A/V DEVICE CIRCUIT DESIGNATOR (V=VISUAL OR A/V, H=AUDIBLE ONLY) SOURCE DESIGNATOR DEVICE DESIGNATOR Z3-1 ZONED INITIATING DEVICE IDC (ZONE) DESIGNATION DEVICE ADDRESS L1D1 ADDRESSABLE DEVICES NUMBERING ADDRESSABLE CARD (SLC) DEVICE TYPE (D=DETECTOR, M=MODULE) DEVICE DESIGNATOR A1:S2-1 SPEAKER DEVICE AMPLIFIER DESIGNATOR SPEAKER CIRCUIT 1.THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 2.SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT TETON SMART SECURITY IN A TIMELY MANNER SO AS NOT TO IMPAIR THE CONSTRUCTION SCHEDULE. 3.CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 4.A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. 5.THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. 6.UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO TETON SMART SECURITY NO LATER THAN 7 DAYS AFTER FINAL TEST. 7.THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. 8.DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED TETON SMART SECURITY TECHNICAL REPRESENTATIVE. 9.ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 10.THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. 11.INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND NEC. 12.ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). 13.FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. 15.FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. 16.FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. 17.FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. 18.ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 19.ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 20.ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 21.120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22.MAINTAIN 40 PERCENT MAXIMUM CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. 23.EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. TETON SMART SECURITY MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. 24.THE FIRE ALARM SYSTEM SHALL BE MONITORED BY A UL LISTED MONITORING STATION VIA TWO COPPER POT LINES. IF TELEPHONES IS NOT PROVIDED A CELLULAR RADIO TRANSMITTER WILL BE PROVIDED AT AN ADDITIONAL COST. PHONE: Project Manager MARTIN PELTON martin@tetonsmartsecurity.com 208-516-0514 PHONE: Drawings Prepared By CENTERS OF DESIGN EXCELLENCE macmckinnon.code@gmail.com 832-474-6891 ACT U A T E A U D I B L E T R O U B L E S I G N A L AC T U A T E A U D I B L E S U P E R V I S O R Y S I G N A L AC T U A T E C O M M O N T R O U B L E S I G N A L I N D I C A T O R AC T U A T E A U D I B L E A L A R M S I G N A L SYSTEM INPUTS AC T U A T E C O M M O N A L A R M S I G N A L I N D I C A T O R SYS T E M O U T P U T S TR A N S M I T S U P V . S I G N A L T O S U P E R V I S I N G S T A T I O N REMARKS CTRL. UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL AC T U A T E C O M M O N S U P E R V I S O R Y S I G N A L I N D I C A T O R ACT U A T E A P P R O P R I A T E L O C A T I O N I N D I C A T O R A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC TR A N S M I T A L A R M S I G N A L T O S U P E R V I S I N G S T A T I O N TR A N S M I T T R O U B L E S I G N A L T O S U P E R V I S I N G S T A T I O N AD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 AE AF AG 31 AH 32 AI AJ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH AI AJ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 SMOKE SENSOR/DETECTOR MANUAL PULL STATION HEAT SENSOR/DETECTOR DUCT SENSOR/DETECTOR FA N S H U T D O W N DA M P E R S H U T D O W N WATERFLOW SWITCH TAMPER SWITCH FIRE PUMP RUNNING FIRE PUMP POWER FROM ALTERNATE SOURCE FIRE PUMP PHASE LOSS/REVERSAL FIRE ALARM AC POWER FAILURE FIRE ALARM SYSTEM LOW BATTERY CLASS B NOTIFICATION CIRCUIT (NAC) - SHORT OPEN CIRCUIT OR GROUND FAULT ACT U A T E A L L V I S I B L E E V A C U A T I O N S I G N A L S AC T U A T E A L L A U D I B L E E V A C U A T I O N S I G N A L S REM O T E L Y D I S P L A Y A C T I V E S T A T U S DISP L A Y C H A N G E O F S T A T U S PLENUM RATED: FPLP AREA=0.0269 SQ. INCH BELDEN 6320FKDNON-PLENUM RATED: FPLR BELDEN 5320FL AREA=0.0189 SQ. INCH NON-PLENUM RATED: FPLR BELDEN 5320UL AREA=0.0179 SQ. INCH K AREA=0.0055 SQ. INCH (EACH) (2) #18 AWG (WHITE/ORANGE) (2) #18 AWG (PINK/BROWN) CONDUIT ONLY: TFFN AREA=0.0179 SQ. INCH BELDEN 6320UL PLENUM RATED: FPLP L NON-PLENUM RATED: FPLR BELDEN 5120UL AREA=0.0356 SQ. INCH P AREA=0.0330 SQ. INCH BELDEN 6120UL PLENUM RATED: FPLP (2) #14 AWG (YELLOW/BLUE) AREA=0.0097 SQ. INCH (EACH) CONDUIT ONLY: THHN CONDUCTOR AREA 0.12 SQ INCH * 0.21 SQ INCH * 0.34 SQ INCH * CONDUIT SIZE 1" 3/4" 1/2" * 40% FILL PER N.E.C. 2" CONDUIT SIZE 1-1/4" 1-1/2" CONDUCTOR AREA 0.60 SQ INCH * 0.82 SQ INCH * 1.34 SQ INCH * THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRICAL CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. ALTERNATE SUPPLIERS MAY BE SUBSTITUTED PROVIDING EQUIVALENT CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. SINGLE CONDUCTOR(THHN,TFFN)PLENUM RATED: FPLP FIRE ALARM WIRE LIST RISER RATED: FPLRCIRCUIT DESCRIPTION DATA/COMMUNICATION - 1 PAIR 18 AWG TWISTED OVERALL SHIELD REMOTE TEST SWITCH/LED CIRCUIT - (2) 2 CONDUCTOR 18 AWG SOLID POWER CIRCUIT - 2 CONDUCTOR 14 AWG SOLID AREA=0.0356 SQ. INCH NON-PLENUM RATED: FPLR BELDEN 5120UL V (2) #14 AWG (RED/BLACK) AREA=0.0097 SQ. INCH (EACH)AREA=0.0330 SQ. INCH CONDUIT ONLY: THHN PLENUM RATED: FPLP BELDEN 6120UL VISUAL/SIGNAL CIRCUIT - 2 CONDUCTOR 14 AWG SOLID NON-PLENUM RATED: FPLR BELDEN 5320UL AREA=0.0179 SQ. INCH Z AREA=0.0179 SQ. INCH BELDEN 6320UL PLENUM RATED: FPLPCONDUIT ONLY: TFFN AREA=0.0055 SQ. INCH (EACH) (2) #18 AWG (YELLOW/BLUE) ZONE CIRCUIT - 2 CONDUCTOR 18 AWG SOLID NON-PLENUM RATED: FPLR BELDEN 5320UL AREA=0.0179 SQ. INCH AREA=0.0179 SQ. INCH BELDEN 6320UL PLENUM RATED: FPLPCONDUIT ONLY: TFFN AREA=0.0055 SQ. INCH (EACH) (2) #18 AWG (YELLOW/BLUE) SLC - 2 CONDUCTOR 18 AWG SOLID NON-PLENUM RATED: FPLR BELDEN 5220UL AREA=0.0238 SQ. INCH S AREA=0.0238 SQ. INCH BELDEN 6220UL PLENUM RATED: FPLPAUDIO CIRCUIT - 1 PAIR 16 AWG TWISTED UNSHIELDED Sheet List Table Sheet Number Sheet Title FA-001 COVER SHEET FA-101.A DEVICE PLACEMENT PLAN - 1ST FLOOR AREA A A-101.B DEVICE PLACEMENT PLAN - 1ST FLOOR AREA B FA-101.C DEVICE PLACEMENT PLAN - 1ST FLOOR AREA C FA-101.D DEVICE PLACEMENT PLAN - 1ST FLOOR AREA D FA-102.A DEVICE PLACEMENT PLAN - 2ND FLOOR AREA A FA-102.B DEVICE PLACEMENT PLAN - 2ND FLOOR AREA B FA-102.C DEVICE PLACEMENT PLAN - 2ND FLOOR AREA C FA-102.D DEVICE PLACEMENT PLAN - 2ND FLOOR AREA D FA-201 RISER DIAGRAM FA-202 RISER DIAGRAM FA-501 PANEL DETAIL FA-601 CALCULATIONS FA-602 CALCULATIONS FA-603 CALCULATIONS FA-701 WIRING TYPICALS A1-S1-25 P1-N4-07 30cd A1-S1-26 P1-N4-06 30cd P1-N4-05 75cd WP A1-S1-28 P1-N4-02 75cd A1-S1-29 EOL P1-N4-01 30cd A1-S1-27 P1-N4-03 15cd A1-S1-24 P1-N4-08 15cd P1-N4-04 15cd P1-N4-09 EOL 4.7k 15cd A1-S1-20 P1-N3-01 95cd A1-S1-19 P1-N2-02 95cd A1-S1-21 P1-N3-02 95cd A1-S1-18 P1-N2-03 95cd A1-S1-22 P1-N3-03 95cd A1-S1-17 P1-N2-04 95cd A1-S1-23 P1-N3-04 EOL 4.7k 95cd A1-S1-16 P1-N2-05 95cd P1-N2-01 75cd WP DH DH DH DH DH A1-S1-07 P1-N1-11 15cd DH DH A1-S1-15 P1-N2-06 15cd A1-S1-11 P1-N1-15 15cd A1-S1-10 P1-N1-14 15cd A1-S1-09 P1-N1-13 30cd A1-S1-08 P1-N1-12 30cd A1-S1-06 P1-N1-10 15cd AIML1-M4 AIM L1-M5 AIML1-M8 AIML1-M9 AIML1-M10 AIML1-M11 AIM L1-M12 AOML1-M7 AOML1-M6 Z1-1 EOL 47k Z1-1 EOL 47k AIM L1-M13KITCHEN HOOD MONITOR 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 2 S 2 V 1 V 1 V 1 1 S 1 V 1 V 1 S 1 V 1 S 1 V 1 1 S 1 V 1 S 1 V 1 S 1 V 1 V 1 S 1 V 2 V 1 S 1 V 1 V 1 S 1 V 1 S 1 V 1 1 S 1 S 1 L 1 L 1 Z 1 Z 168 ROOM TOILET 164 KINDERGARTEN 161 KINDERGARTEN 165 CORRIDOR 160 VEST. 159 OVERFLOW155 GYMNASIUM144 CAFETERIA 158 CLOSET156 CORRIDOR 157 VEST 152 MECH/ELEC 149 DRY STORAGE 150 TOILET 153 STORAGE 151 CUSTODIAN146 DISH 145 SERV 147 KITCHEN 148 OFFICE 142 TESTING CUSTODIAN 1 S 1 V 1 P1 P 1 P 1 P 1 P 1 P 1 Z 1 Z S L1-D23 S L1-D24 S L1-D25 S L1-D261 L 1 L 1 L 1 L 1 L SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 0 SCALE:IN FEET1/8" = 1'-0" 4'8'16' N SCALE:1/8" = 1'-0" DEVICE PLACEMENT PLAN - 1ST FLOOR AREA A MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-101.A DEVICE PLACEMENT PLAN - 1ST FLOOR AREA A HI B B A R D E L E M E N T A R Y SC H O O L GENERAL NOTES: 1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 2.TAP ALL SPEAKERS AT 0.5W UNLESS NOTED OTHERWISE. 3.SET ALL SPEAKER VOLTAGE JUMPERS TO THE 25V SETTING. KEYNOTES: HOMERUN TO NAC PANEL P1. HOMERUN TO NAC PANEL P2. HOMERUN TO FACP. 1 2 3 DC B A KEYPLAN F>YbSB>bYÑVWM>UWÑbWWVWVÑ >bÑfWghfccCÑSfWS• 2 gÑd WfÑA 7 C 2 ÑÁ ½ Ѥ Á •¤  •) • Ñ SbVÑ( ÑSÑCSbi SBÑX>fWÑSBSfCÑ T cm ÑgZ SBBÑT WÑBcUShWVÑl >hZ >bÑ( XWWhÑcXÑWSUZ ÑWm >hÑVccfl Sn Ñ WSUZ ÑXBccfÑSbVÑWMWfn ѽ Ž Ž Ñ XWWhÑVcl bÑSÑUcff>Vcf• P1-N2-01 DH DH DH DH DH A1-S1-07 P1-N1-11 15cd DH DH A1-S1-15 P1-N2-06 15cd A1-S1-11 P1-N1-15 15cd A1-S1-10 P1-N1-14 15cd A1-S1-12 P1-N1-16 75cd A1-S1-13 P1-N2-09 75cd A1-S1-14 P1-N2-07 75cd P1-N1-17 EOL 4.7k 15cd P1-N2-10 EOL 4.7k 15cd P1-N2-08 15cd A1-S1-02 P1-N1-04 30cd A1-S1-09 P1-N1-13 30cd A1-S1-08 P1-N1-12 30cd P1-N1-07 15cd P1-N1-05 15cd A1-S1-03 P1-N1-06 15cd A1-S1-06 P1-N1-10 15cd A1-S1-04 P1-N1-08 15cd A1-S1-05 P1-N1-09 15cd P1-N1-03 15cd P1-N1-01 15cd A1-S1-01 P1-N1-02 30cd A1-S3-01 P1-N6-01 30cd A1-S3-03 P1-N6-03 30cd A1-S3-02 P1-N6-02 15cd A1-S2-02 P1-N5-02 15cd A1-S2-01 P1-N5-01 15cd A1-S2-03 P1-N5-03 15cd A1-S2-05 P1-N5-05 15cd A1-S2-07 P1-N5-09 15cd A1-S2-09 P1-N5-11 15cd A1-S2-04 P1-N5-04 75cd A1-S2-06 P1-N5-06 75cd A1-S2-08 P1-N5-10 75cd A1-S2-11 P1-N5-13 75cd A1-S2-12 P1-N5-14 EOL 4.7k 75cd A1-S2-18 P2-N1-06 75cd A1-S2-17 P2-N1-05 15cd P1-N5-08 15cd P1-N5-07 15cd A1-S2-16 P2-N1-04 30cd A1-S2-14 P2-N1-02 30cd A1-S2-13 P2-N1-01 30cd A1-S2-15 P2-N1-03 30cd A1-S4-01 P2-N4-01 75cd A1-S3-04 P1-N6-04 30cd A1-S3-05 P1-N6-06 30cd AOM L1-M3 SOUND SYSTEM SHUTDOWN P1-N6-05 75cd WP A1-S2-10 P1-N5-12 15cd F L1-M1 HL1-D21 135 FT AOML1-M2 NA C P1 NA C P2 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 2 S 2 V 2 S 2 V 2 S 2 V 1 V 2 V 2 V 2 S 2 V 2 S 2 V 2 V 1 S 1 V 2 S 2 V 2 S 2 V 1 V 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 2 V 2 S 2 V 1 S 1 V 1 S 1 V 2 S 2 V 2 V 1 V 1 1 1 S 1 V 2 S 2 V 2 V 1 S 1 V 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 2 S 2 V 2 S 2 V 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 1 2 S 2 V 2 S 2 V 1 S 1 V 2 V 1 S 1 V 2 V 1 S 1 V 2 S 2 V 1 S 1 V 2 1 S 1 V 1 V 1 S 1 V 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 2 1 S 1 V 1 S 1 V 1 S AM P A1 1 S 1 V 1 S 1 V 1 S 2 V 3 3 3 FAA 1 D, 1 P S L1-D1 1 L 1 L 2 L 1 L 101 ENTRY 102 179 CONF. 178 PRINCIPAL 181 WAIT 180 RECEPTION 182 CORRIDOR 177 TOILET 175 SUSPENSION 176 ROOM WORK 174 STOR. 173 ROOM BREAK 172 HALL 170 WOMAN 171 MEN 169 GIRLS 167 BOYS 168 ROOM TOILET 166 STORAGE 164 KINDERGARTEN 161 KINDERGARTEN BA7 KINDERGARTEN 165 CORRIDOR 160 VEST. 142 TESTING 141 TESTING 140 CORRIDOR 139 CLASSROOM137 CLASSROOM 135 CLASSROOM 130 CLASSROOM 136 CORRIDOR 131 STORAGE DIST. 132 STORAGE OUTSIDE 133 STORAGE INSIDE 134 VESTIBULE 138 CORRIDOR 183 CONF 184 WORK 194 CENTER MEDIA 186 CUST187 TLT 188 ACCESS 189 ROOM WORK 129 CLASSROOM 190 192 GIRLS 128 CORRIDOR 1 S 1 V 1 P 1 P 1 P 1 P 1 P 1 P 1 P 2 SS S L1-D2 SL1-D19S L1-D18 S L1-D16 S L1-D22 S L1-D20 S L1-D17 S L1-D23 S L1-D24 S L1-D25 S L1-D26 FA C U F1 SL1-D15 1 L 1 L 1 L 1 L 1 L 1 L 2 L 1 L 1 L 2 L 1 L 1 L 1 L 1 L 1 L 3 SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 0 SCALE:IN FEET1/8" = 1'-0" 4'8'16' N SCALE:1/8" = 1'-0" DEVICE PLACEMENT PLAN - 1ST FLOOR AREA B MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O A-101.B DEVICE PLACEMENT PLAN - 1ST FLOOR AREA B HI B B A R D E L E M E N T A R Y SC H O O L GENERAL NOTES: 1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 2.TAP ALL SPEAKERS AT 0.5W UNLESS NOTED OTHERWISE. 3.SET ALL SPEAKER VOLTAGE JUMPERS TO THE 25V SETTING. KEYNOTES: HOMERUN TO NAC PANEL P1. HOMERUN TO NAC PANEL P2. HOMERUN TO FACP. 1 2 3 DC B A KEYPLAN A1-S2-18 P2-N1-06 75cd A1-S2-21 P2-N1-09 75cd A1-S2-23 P2-N1-11 75cd A1-S2-26 EOL P2-N1-14 EOL 4.7k 75cd A1-S4-13 EOL P2-N2-08 EOL 4.7k 75cd A1-S4-11 P2-N2-05 75cd A1-S4-10 P2-N2-04 75cd A1-S4-09 P2-N2-03 75cd A1-S4-08 P2-N2-02 75cd A1-S4-07 P2-N2-01 75cd A1-S3-22 P2-N3-10 75cd A1-S2-15 A1-S4-01 P2-N4-01 75cd A1-S4-06 P2-N4-07 EOL 4.7k 30cd A1-S4-05 P2-N4-06 30cd A1-S4-04 P2-N4-05 15cd A1-S2-19 P2-N1-07 15cd P2-N4-04 15cd A1-S4-02 P2-N4-02 75cd A1-S2-20 P2-N1-08 15cd A1-S2-22 P2-N1-10 15cd A1-S2-24 P2-N1-12 15cd DH DH A1-S2-25 P2-N1-13 15cd A1-S4-12 P2-N2-07 15cd P2-N2-06 75cd WP A1-S4-03 P2-N4-03 15cd 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 2 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 2 V 1 S 1 V 1 S 1 V 1 S 1 V 2 2 S 2 V 2 V 1 S 1 V 1 S 1 V 1 S 1 V 2 S 1 V 1 S 1 V 2 S 1 V 1 S BA4 CLASSROOM BA2 CLASSROOM BA6 CLASSROOM BA1 CLASSROOM BA5 CORRIDOR BA3 VESTIBULE 123 CLASSROOM 125 CLASSROOM 122 CLASSROOM 121 CLASSROOM 119 CLASSROOM 194 CENTER MEDIA 193 TOILET 189 ROOM WORK 127 CLASSROOM 126 CLASSROOM 124 CORRIDOR 120 CORRIDOR 190 BOYS 192 GIRLS 128 CORRIDOR 1 P 1 P S L1-D13 S L1-D12 S L1-D11 S L1-D10 S L1-D9 S L1-D14 S L1-D8 SL1-D15 2 L 2 L 1 L 2 L 1 L 1 L 2 L 1 L SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 0 SCALE:IN FEET1/8" = 1'-0" 4'8'16' N SCALE:1/8" = 1'-0" DEVICE PLACEMENT PLAN - 1ST FLOOR AREA C MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-101.C DEVICE PLACEMENT PLAN - 1ST FLOOR AREA C HI B B A R D E L E M E N T A R Y SC H O O L GENERAL NOTES: 1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 2.TAP ALL SPEAKERS AT 0.5W UNLESS NOTED OTHERWISE. 3.SET ALL SPEAKER VOLTAGE JUMPERS TO THE 25V SETTING. KEYNOTES: HOMERUN TO NAC PANEL P1. HOMERUN TO NAC PANEL P2. HOMERUN TO FACP. 1 2 3 DC B A KEYPLAN A1-S4-07 P2-N2-01 75cd A1-S3-22 EOL P2-N3-10 EOL 4.7k 75cd A1-S3-21 P2-N3-09 75cd A1-S3-20 P2-N3-08 75cd A1-S3-19 P2-N3-07 75cd A1-S3-18 P2-N3-06 75cd A1-S3-16 P2-N3-03 75cd A1-S3-15 P2-N3-02 75cd A1-S3-12 P1-N6-14 75cd A1-S2-15 P2-N1-03 A1-S4-01 P2-N4-01 75cd A1-S3-04 P1-N6-04 30cd A1-S3-05 P1-N6-06 30cd EOL 4.7k A1-S4-05 P2-N4-06 30cd A1-S4-04 P2-N4-05 15cd P2-N4-04 15cd A1-S4-02 P2-N4-02 75cd A1-S4-03 P2-N4-03 15cd A1-S3-06 P1-N6-07 15cd A1-S3-07 P1-N6-08 75cd A1-S3-08 P1-N6-09 15cd A1-S3-10 P1-N6-11 30cd A1-S3-11 P1-N6-13 30cd P1-N6-12 15cd A1-S3-09 P1-N6-10 15cd A1-S3-13 P1-N6-15 EOL 4.7k 15cd A1-S3-14 P2-N3-01 15cd A1-S3-17 P2-N3-04 15cd DH DH P2-N3-05 75cd WP P1-N6-05 75cd WP 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 2 V 1 S 1 V 2 V 1 S 1 V 1 S 1 V 2 1 V 1 S 1 V 2 1 S 1 V 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 2 V 2 2 S 2 V 2 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 S 3 1 D, 1 P 121 CLASSROOM 119 CLASSROOM 118 CLASSROOM 116 CLASSROOM 115 CLASSROOM 113 CLASSROOM 109 CLASSROOM 110 CLASSROOM 111 CLASSROOM 107 SPEECH 106 ESL 103 RM A RESOURCE 114 CORRIDOR 105 ROOM QUIET 104 TESTING 101 ENTRY 102 CORRIDOR 194 CENTER MEDIA 193 TOILET 189 ROOM WORK 120 CORRIDOR 192 GIRLS 1 P 1 P 1 P 2 S L1-D8 S L1-D4 SL1-D5 S L1-D6 S L1-D7 S L1-D3 1 L 2 L 2 L 1 L 2 L 2 L 1 L 1 L 3 SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 0 SCALE:IN FEET1/8" = 1'-0" 4'8'16' N SCALE:1/8" = 1'-0" DEVICE PLACEMENT PLAN - 1ST FLOOR AREA D MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-101.D DEVICE PLACEMENT PLAN - 1ST FLOOR AREA D HI B B A R D E L E M E N T A R Y SC H O O L GENERAL NOTES: 1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 2.TAP ALL SPEAKERS AT 0.5W UNLESS NOTED OTHERWISE. 3.SET ALL SPEAKER VOLTAGE JUMPERS TO THE 25V SETTING. KEYNOTES: HOMERUN TO NAC PANEL P1. HOMERUN TO NAC PANEL P2. HOMERUN TO FACP. 1 2 3 DC B A KEYPLAN S L1-D30 S L1-D31 AOM L1-M18 S L1-D29 S L1-D28 S L1-D27 AOM L1-M17 AOM L1-M16 AOM L1-M15 AOM L1-M14 OA-1 HP-5AHP-5BHP-4AHP-4B A1-S5-01 F1-N1-01 95cd A1-S5-02 EOL F1-N1-02 EOL 4.7k 95cd S L1-D32 AOM L1-M19 OA-2 S L1-D33 AOM L1-M20 HP-6A S L1-D34 AOM L1-M21 HP-6B F1-N2-03 75cd A1-S6-05 EOL F1-N2-05 EOL 4.7k 15cd A1-S6-04 F1-N2-04 15cd A1-S6-02 F1-N2-02 15cd 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 1 S 1 V 1 L1 L 1 L 1 L 1 L 1 K 1 K 1 K 1 K 1 K 2 L 2 L 1 L 1 L 3 3 3 216 CORRIDOR 215 CORRIDOR 1 K 1 K 1 K SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 0 SCALE:IN FEET1/8" = 1'-0" 4'8'16' N SCALE:1/8" = 1'-0" DEVICE PLACEMENT PLAN - 2ND FLOOR AREA A MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-102.A DEVICE PLACEMENT PLAN - 2ND FLOOR AREA A HI B B A R D E L E M E N T A R Y SC H O O L GENERAL NOTES: 1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 2.TAP ALL SPEAKERS AT 0.5W UNLESS NOTED OTHERWISE. 3.SET ALL SPEAKER VOLTAGE JUMPERS TO THE 25V SETTING. KEYNOTES: HOMERUN TO NAC PANEL P1. HOMERUN TO NAC PANEL P2. HOMERUN TO FACP. 1 2 3 DC B A KEYPLAN S L1-D32 AOM L1-M19 OA-2 S L1-D33 AOM L1-M20 HP-6A S L1-D34 AOM L1-M21 HP-6B A1-S6-03 F1-N2-03 75cd A1-S6-05 EOL F1-N2-05 EOL 4.7k 15cd A1-S6-04 F1-N2-04 15cd A1-S6-02 F1-N2-02 15cd A1-S6-01 F1-N2-01 15cd A1-S7-01 F1-N3-01 15cd A1-S7-06 F1-N3-06 15cd A1-S7-02 F1-N3-02 15cd A1-S7-03 F1-N3-03 15cd A1-S7-05 F1-N3-05 15cd A1-S7-04 F1-N3-04 15cd 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 L 2 L 2 L 1 L 1 L 3 3 3 3 215 CORRIDOR 213 CORRIDOR 202 CORRIDOR 203 CORRIDOR 204 CORRIDOR 212 CORRIDOR 1 K 1 K 1 K SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 0 SCALE:IN FEET1/8" = 1'-0" 4'8'16' N SCALE:1/8" = 1'-0" DEVICE PLACEMENT PLAN - 2ND FLOOR AREA B MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-102.B DEVICE PLACEMENT PLAN - 2ND FLOOR AREA B HI B B A R D E L E M E N T A R Y SC H O O L GENERAL NOTES: 1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 2.TAP ALL SPEAKERS AT 0.5W UNLESS NOTED OTHERWISE. 3.SET ALL SPEAKER VOLTAGE JUMPERS TO THE 25V SETTING. KEYNOTES: HOMERUN TO NAC PANEL P1. HOMERUN TO NAC PANEL P2. HOMERUN TO FACP. 1 2 3 DC B A KEYPLAN A1-S8-06 F1-N4-06 15cd A1-S7-09 F1-N3-09 15cd A1-S7-08 F1-N3-08 15cd A1-S7-10 F1-N3-10 15cd A1-S7-11 EOL F1-N3-11 EOL 4.7k 15cd S L1-D36 AOM L1-M23 OA-3 S L1-D37 AOM L1-M24 OA-3 A1-S7-07 F1-N3-07 15cd A1-S8-08 EOL F1-N4-08 EOL 4.7k 30cd A1-S8-07 F1-N4-07 30cd 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 1 S 1 V 1 L 1 L CORRIDOR 207 CORRIDOR 206 CORRIDOR 205 CORRIDOR 1 K 1 K SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 0 SCALE:IN FEET1/8" = 1'-0" 4'8'16' N SCALE:1/8" = 1'-0" DEVICE PLACEMENT PLAN - 2ND FLOOR AREA C MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-102.C DEVICE PLACEMENT PLAN - 2ND FLOOR AREA C HI B B A R D E L E M E N T A R Y SC H O O L GENERAL NOTES: 1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 2.TAP ALL SPEAKERS AT 0.5W UNLESS NOTED OTHERWISE. 3.SET ALL SPEAKER VOLTAGE JUMPERS TO THE 25V SETTING. KEYNOTES: HOMERUN TO NAC PANEL P1. HOMERUN TO NAC PANEL P2. HOMERUN TO FACP. 1 2 3 DC B A KEYPLAN A1-S8-01 F1-N4-01 15cd A1-S8-02 F1-N4-02 15cd A1-S8-04 F1-N4-04 15cd A1-S8-03 F1-N4-03 15cd S L1-D35 AOM L1-M22 OA-4 A1-S8-05 F1-N4-05 15cd A1-S8-06 F1-N4-06 15cd A1-S7-07 F1-N3-07 15cd A1-S8-08 EOL F1-N4-08 EOL 4.7k 30cd A1-S8-07 F1-N4-07 30cd 1 S 1 V 1 S 1 V 1 S 1 V 2 S 2 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 S 1 V 1 L 2 L 3 204 CORRIDOR CORRIDOR 210 CORRIDOR 207 CORRIDOR 211 CORRIDOR 1 K SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 0 SCALE:IN FEET1/8" = 1'-0" 4'8'16' N SCALE:1/8" = 1'-0" DEVICE PLACEMENT PLAN - 2ND FLOOR AREA D MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-102.D DEVICE PLACEMENT PLAN - 2ND FLOOR AREA D HI B B A R D E L E M E N T A R Y SC H O O L GENERAL NOTES: 1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 2.TAP ALL SPEAKERS AT 0.5W UNLESS NOTED OTHERWISE. 3.SET ALL SPEAKER VOLTAGE JUMPERS TO THE 25V SETTING. KEYNOTES: HOMERUN TO NAC PANEL P1. HOMERUN TO NAC PANEL P2. HOMERUN TO FACP. 1 2 3 DC B A KEYPLAN P2-N4-01 75cd P2-N4-02 75cd P2-N4-03 15cd P2-N4-04 15cd P2-N4-05 15cd P2-N4-06 30cd P2-N4-07 EOL 4.7k 30cd P2-N3-01 15cd P2-N3-02 75cd P2-N3-03 75cd P2-N3-04 15cd P2-N3-05 75cd WP P2-N3-06 75cd P2-N3-07 75cd P2-N3-08 75cd P2-N3-09 75cd P2-N3-10 EOL 4.7k 75cd P2-N2-01 75cd P2-N2-02 75cd P2-N2-03 75cd P2-N2-04 75cd P2-N2-05 75cd P2-N2-06 75cd WP P2-N2-07 15cd P2-N2-08 EOL 4.7k 75cd P2-N1-01 30cd P2-N1-02 30cd P2-N1-03 30cd P2-N1-04 30cd P2-N1-05 15cd P2-N1-06 75cd P2-N1-07 15cd P2-N1-08 15cd P2-N1-09 75cd P2-N1-10 15cd P2-N1-11 75cd P2-N1-12 15cd P2-N1-13 15cd P2-N1-14 EOL 4.7k 75cd DH AUX2-01 DH AUX2-02 DH AUX2-03 DH AUX2-04 DEDICATED 120V 20 AMP CIRCUIT H N G NAC EXPANDER POWER SUPPLY P2 DH AUX1-01 DH AUX1-02 DH AUX1-03 DH AUX1-04 DH AUX1-05 DH AUX1-06 DH AUX1-07 P1-N6-01 30cd P1-N6-02 15cd P1-N6-03 30cd P1-N6-04 30cd P1-N6-05 75cd WP P1-N6-06 30cd P1-N6-07 15cd P1-N6-08 75cd P1-N6-09 15cd P1-N6-10 15cd P1-N6-11 30cd P1-N6-12 15cd P1-N6-13 30cd P1-N6-14 75cd P1-N6-15 EOL 4.7k 15cd P1-N5-01 15cd P1-N5-02 15cd P1-N5-03 15cd P1-N5-04 75cd P1-N5-05 15cd P1-N5-06 75cd P1-N5-07 15cd P1-N5-08 15cd P1-N5-09 15cd P1-N5-10 75cd P1-N5-11 15cd P1-N5-12 15cd P1-N5-13 75cd P1-N5-14 EOL 4.7k 75cd P1-N4-01 30cd P1-N4-02 75cd P1-N4-03 15cd P1-N4-04 15cd P1-N4-05 75cd WP P1-N4-06 30cd P1-N4-07 30cd P1-N4-08 15cd P1-N4-09 EOL 4.7k 15cd P1-N3-01 95cd P1-N3-02 95cd P1-N3-03 95cd P1-N3-04 EOL 4.7k 95cd P1-N2-01 75cd WP P1-N2-02 95cd P1-N2-03 95cd P1-N2-04 95cd P1-N2-05 95cd P1-N2-06 15cd P1-N2-07 75cd P1-N2-08 15cd P1-N2-09 75cd P1-N2-10 EOL 4.7k 15cd DEDICATED 120V 20 AMP CIRCUIT H N G NAC EXPANDER POWER SUPPLY P1 P1-N1-01 15cd P1-N1-02 30cd P1-N1-03 15cd P1-N1-04 30cd P1-N1-05 15cd P1-N1-06 15cd P1-N1-07 15cd P1-N1-08 15cd P1-N1-09 15cd P1-N1-10 15cd P1-N1-11 15cd P1-N1-12 30cd P1-N1-13 30cd P1-N1-14 15cd P1-N1-15 15cd P1-N1-16 75cd P1-N1-17 EOL 4.7k 15cd Z1-1 EOL 47k ANNUNCIATOR SBUS+-1 DEDICATED 120V 20 AMP CIRCUIT H N G FIRE ALARM CONTROL UNIT F1 F L1-M1 S L1-D1 AOM L1-M2 AOM L1-M3 S L1-D2 S L1-D3 S L1-D4 S L1-D5 S L1-D6 S L1-D7 S L1-D8 S L1-D9 S L1-D10 S L1-D11 S L1-D12 S L1-D13 S L1-D14 S L1-D15 S L1-D16 S L1-D17 S L1-D18 S L1-D19 S L1-D20 H L1-D21 135 FT S L1-D22 S L1-D23 S L1-D24 S L1-D25 S L1-D26 AIM L1-M4 AIM L1-M5 AOM L1-M6 AOM L1-M7 AIM L1-M8 AIM L1-M9 AIM L1-M10 AIM L1-M11 AIM L1-M12 AIM L1-M13 A1-S4-01 0.5w A1-S4-02 0.5w A1-S4-03 0.5w A1-S4-04 0.5w A1-S4-05 0.5w A1-S4-06 0.5w A1-S4-07 0.5w A1-S4-08 0.5w A1-S4-09 0.5w A1-S4-10 0.5w A1-S4-11 0.5w A1-S4-12 0.5w A1-S4-13 EOL 0.5w A1-S3-01 0.5w A1-S3-02 0.5w A1-S3-03 0.5w A1-S3-04 0.5w A1-S3-05 0.5w A1-S3-06 0.5w A1-S3-07 0.5w A1-S3-08 0.5w A1-S3-09 0.5w A1-S3-10 0.5w A1-S3-11 0.5w A1-S3-12 0.5w A1-S3-13 0.5w A1-S3-14 0.5w A1-S3-15 0.5w A1-S3-16 0.5w A1-S3-17 0.5w A1-S3-18 0.5w A1-S3-19 0.5w A1-S3-20 0.5w A1-S3-21 0.5w A1-S3-22 EOL 0.5w A1-S2-01 0.5w A1-S2-02 0.5w A1-S2-03 0.5w A1-S2-04 0.5w A1-S2-05 0.5w A1-S2-06 0.5w A1-S2-07 0.5w A1-S2-08 0.5w A1-S2-09 0.5w A1-S2-10 0.5w A1-S2-11 0.5w A1-S2-12 0.5w A1-S2-13 0.5w A1-S2-14 0.5w A1-S2-15 0.5w A1-S2-16 0.5w A1-S2-17 0.5w A1-S2-18 0.5w A1-S2-19 0.5w A1-S2-20 0.5w A1-S2-21 0.5w A1-S2-22 0.5w A1-S2-23 0.5w A1-S2-24 0.5w A1-S2-25 0.5w A1-S2-26 EOL 0.5w A1-S1-29 EOL 0.5w A1-S1-28 0.5w A1-S1-27 0.5w A1-S1-26 0.5w A1-S1-25 0.5w A1-S1-24 0.5w A1-S1-23 0.5w A1-S1-22 0.5w A1-S1-21 0.5w A1-S1-20 0.5w A1-S1-19 0.5w A1-S1-18 0.5w A1-S1-17 0.5w A1-S1-16 0.5w A1-S1-15 0.5w A1-S1-14 0.5w A1-S1-13 0.5w A1-S1-12 0.5w A1-S1-11 0.5w A1-S1-10 0.5w A1-S1-09 0.5w A1-S1-08 0.5w A1-S1-07 0.5w A1-S1-06 0.5w A1-S1-05 0.5w A1-S1-04 0.5w A1-S1-03 0.5w A1-S1-02 0.5w A1-S1-01 0.5w DEDICATED 120V 20 AMP CIRCUIT H N G AMPLIFIER PANEL A1 1P 1Z 1P 1V 1L 1S 1P 1V 1Z 1D, 1 P 1S 1V 1V 1Z 1V 1V 1S 1Z 1V 1V 1V 1V 1S 1ST FLOOR 2ND FLOOR SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 SCALE:N.T.S. RISER DIAGRAM MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-201 RISER DIAGRAM HI B B A R D E L E M E N T A R Y SC H O O L RISER NOTES: 1.RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE SYSTEM ARCHITECTURE IN BUILDING CROSS SECTION. IT IS NOT INTENDED TO REPRESENT ACTUAL WIRE RUNS, PANEL CONFIGURATIONS OR PENETRATIONS. REFER TO FLOOR PLANS AND PANEL DETAILS FOR CIRCUIT ROUTING AND CONFIGURATION INFORMATION. 2.ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICAL CODES. REFER TO 'APPLICABLE CODES & STANDARDS' ON SHEET FA-001 FOR SPECIFIC CODE REFERENCES. F1-N4-01 15cd F1-N4-02 15cd F1-N4-03 15cd F1-N4-04 15cd F1-N4-05 15cd F1-N4-06 15cd F1-N4-07 30cd F1-N4-08 EOL 4.7k 30cd F1-N3-01 15cd F1-N3-02 15cd F1-N3-03 15cd F1-N3-04 15cd F1-N3-05 15cd F1-N3-06 15cd F1-N3-07 15cd F1-N3-08 15cd F1-N3-09 15cd F1-N3-10 15cd F1-N3-11 EOL 4.7k 15cd F1-N2-01 15cd F1-N2-02 15cd F1-N2-03 75cd F1-N2-04 15cd F1-N2-05 EOL 4.7k 15cd F1-N1-01 95cd F1-N1-02 EOL 4.7k 95cd S L1-D27 AOM L1-M14 S L1-D28 AOM L1-M15 S L1-D29 AOM L1-M16 S L1-D30 AOM L1-M17 S L1-D31 AOM L1-M18 S L1-D32 AOM L1-M19 S L1-D33 AOM L1-M20 S L1-D34 AOM L1-M21 S L1-D35 AOM L1-M22 AOM L1-M23 S L1-D36 AOM L1-M24 S L1-D37 A1-S8-01 0.5w A1-S8-02 0.5w A1-S8-03 0.5w A1-S8-04 0.5w A1-S8-05 0.5w A1-S8-06 0.5w A1-S8-07 0.5w A1-S8-08 EOL 0.5w A1-S7-01 0.5w A1-S7-02 0.5w A1-S7-03 0.5w A1-S7-04 0.5w A1-S7-05 0.5w A1-S7-06 0.5w A1-S7-07 0.5w A1-S7-08 0.5w A1-S7-09 0.5w A1-S7-10 0.5w A1-S7-11 EOL 0.5w A1-S6-01 0.5w A1-S6-02 0.5w A1-S6-03 0.5w A1-S6-04 0.5w A1-S6-05 EOL 0.5w A1-S5-01 0.5w A1-S5-02 EOL 0.5w 1L 1K 1V 1V 1S 1V 1S 1V 1S 1S 1K 1K 1K 1K 1K 1K 1K 1K 1K 1K 2ND FLOOR SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 SCALE:N.T.S. RISER DIAGRAM MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-202 RISER DIAGRAM HI B B A R D E L E M E N T A R Y SC H O O L RISER NOTES: 1.RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE SYSTEM ARCHITECTURE IN BUILDING CROSS SECTION. IT IS NOT INTENDED TO REPRESENT ACTUAL WIRE RUNS, PANEL CONFIGURATIONS OR PENETRATIONS. REFER TO FLOOR PLANS AND PANEL DETAILS FOR CIRCUIT ROUTING AND CONFIGURATION INFORMATION. 2.ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICAL CODES. REFER TO 'APPLICABLE CODES & STANDARDS' ON SHEET FA-001 FOR SPECIFIC CODE REFERENCES. NAC CKT 6 NAC CKT 5 NAC CKT 4 NAC CKT 3 NAC CKT 2 NAC CKT 1 RELAYS TROUBLE RELAY SBUS IN/OUT TO BATT. SLC SLC SLC PGM AC POWER INPUT SBUS VBUS2 VBUS1 AUX AUDIO INPUT AUX AUDIO TRIGGER S- S+ A B TO SBUS1 OUT ON FACP SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-501 PANEL DETAIL HI B B A R D E L E M E N T A R Y SC H O O L SCALE: PANEL DETAIL N.T.S. SCALE: 6860 ANNUNCIATOR DETAIL N.T.S. SCALE: EVS-100W DETAIL N.T.S. C BWSgWÑd fcM>VWÑUi hÑgZ WWhgÑXcfÑhZ WÑVWM>UWg¿We i >d CWbhÑhcÑT WÑi gWV• PANEL LOAD SUMMARY STANDBY CURRENT (AMPS)ALARM CURRENT (AMPS) PANEL A1 (EVS-100W) SUMMARY REPORT PANEL COMPONENT SUMMARY QTY PART NO DESCRIPTION CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL 1 EVS-100W MAIN BOARD PANEL COMPONENT, INTELLIGENT 50/100 WATT AMPLIFIER 1 x 0.19 = 0.19 1 x 1.31 = 1.31 CIRCUIT SUMMARY CIRCUIT S1-1 x 0 = 0 1 x 0 = 0 S2-1 x 0 = 0 1 x 0 = 0 S3-1 x 0 = 0 1 x 0 = 0 S4-1 x 0 = 0 1 x 0 = 0 S5-1 x 0 = 0 1 x 0 = 0 S6-1 x 0 = 0 1 x 0 = 0 S7-1 x 0 = 0 1 x 0 = 0 S8-1 x 0 = 0 1 x 0 = 0 TOTAL STANDBY CURRENT 0.19 TOTAL ALARM CURRENT 1.31 CIRCUIT DETAILS AND CALCULATIONS STANDBY CURRENT ALARM CURRENT SPEAKER POWER/DB LOSS CALCULATIONS SOURCE CIRCUIT AWG SYMBOL QTY PART NO DEVICE SETTING CIRCUIT LENGTH CIRCUIT RESISTANCE (Ω/ft) CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL (A)TOTAL USED WATTS STARTING CALCULATION VOLTAGE END OF LINE VOLTAGE POWER LOSS PERCENT TOTAL DB LOSS EVS-100W MAIN BOARD S1-16 27 SPSCWL 0.5w 1039'0.00489 27 x 0 = 0 27 x 0 = 0 14.5w 25v 22.1v 11.60 %-2.336359dB 2 SPSRL 0.5w 2 x 0 = 0 2 x 0 = 0 S2-16 25 SPSCWL 0.5w 900'0.00489 25 x 0 = 0 25 x 0 = 0 13w 25v 22.47v 10.10 %-1.756595dB 1 SPSRL 0.5w 1 x 0 = 0 1 x 0 = 0 S3-16 22 SPSCWL 0.5w 754'0.00489 22 x 0 = 0 22 x 0 = 0 11w 25v 23.48v 6.09 %-1.207984dB S4-16 13 SPSCWL 0.5w 559'0.00489 13 x 0 = 0 13 x 0 = 0 6.5w 25v 24.2v 3.19 %-0.50814dB S5-16 2 SPSCWL 0.5w 235'0.00489 2 x 0 = 0 2 x 0 = 0 1w 25v 24.92v 0.33 %-0.032017dB S6-16 5 SPSCWL 0.5w 247'0.00489 5 x 0 = 0 5 x 0 = 0 2.5w 25v 24.86v 0.57 %-0.084221dB S7-16 11 SPSCWL 0.5w 446'0.00489 11 x 0 = 0 11 x 0 = 0 5.5w 25v 24.47v 2.11 %-0.339843dB S8-16 8 SPSCWL 0.5w 493'0.00489 8 x 0 = 0 8 x 0 = 0 4w 25v 24.53v 1.87 %-0.272326dB SECONDARY POWER SOURCE REQUIREMENTS REQUIRED STANDBY TIME = 24 HOURS PROVIDE (2) 12V 7AH BATTERIES @ 24VDC REQUIRED ALARM TIME = 15 MINUTES SECONDARY STANDBY LOAD 0.19 x 24 = 4.56 AH SECONDARY ALARM LOAD 1.31 x 0.25 = 0.33 AH STANDBY AND ALARM LOAD SUBTOTAL 4.89 AH DERATING FACTOR x 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS)5.87 AH PANEL LOAD SUMMARY STANDBY CURRENT (AMPS)ALARM CURRENT (AMPS) PANEL F1 (6820EVS) SUMMARY REPORT PANEL COMPONENT SUMMARY QTY PART NO DESCRIPTION CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL 1 6820EVS Main Board Main Board 1 x 0.19 = 0.19 1 x 0.25 = 0.25 CIRCUIT SUMMARY CIRCUIT L1 1 x 0.014895 = 0.014895 1 x 0.214795 = 0.214795 N1 1 x 0 = 0 1 x 0.268 = 0.268 N2 1 x 0 = 0 1 x 0.275 = 0.275 N3 1 x 0 = 0 1 x 0.451 = 0.451 N4 1 x 0 = 0 1 x 0.372 = 0.372 SBUS+1 x 0.027 = 0.027 1 x 0.053 = 0.053 TOTAL STANDBY CURRENT 0.231895 TOTAL ALARM CURRENT 1.883795 CIRCUIT DETAILS AND CALCULATIONS STANDBY CURRENT ALARM CURRENT SOURCE CIRCUIT AWG SYMBOL QTY PART NO DEVICE SETTING CIRCUIT LENGTH CIRCUIT RESISTANCE (Ω/ft) CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL (A) 6820EVS Main Board L1 18 1 SK-CONTROL 2930'0.00777 1 x 0.000375 = 0.000375 1 x 0.000375 = 0.000375 11 SK-DUCT-W w/SK-PHOTO-R-W 11 x 0.0002 = 0.0022 11 x 0.0045 = 0.0495 1 SK-HEAT-W w/B300-6 1 x 0.0002 = 0.0002 1 x 0.0045 = 0.0045 8 SK-MONITOR 8 x 0.0004 = 0.0032 8 x 0.0055 = 0.044 25 SK-PHOTO-W w/B300-6 25 x 0.0002 = 0.005 25 x 0.0045 = 0.1125 1 SK-PULL-DA 1 x 0.00035 = 0.00035 1 x 0.00035 = 0.00035 14 SK-RELAY 14 x 0.000255 = 0.00357 14 x 0.000255 = 0.00357 N1 14 2 SPSCWL 95cd 234'0.00307 2 x 0 = 0 2 x 0.134 = 0.268 N2 14 4 SPSCWL 15cd 248'0.00307 4 x 0 = 0 4 x 0.041 = 0.164 1 SPSCWL 75cd 1 x 0 = 0 1 x 0.111 = 0.111 N3 14 11 SPSCWL 15cd 447'0.00307 11 x 0 = 0 11 x 0.041 = 0.451 N4 14 6 SPSCWL 15cd 494'0.00307 6 x 0 = 0 6 x 0.041 = 0.246 2 SPSCWL 30cd 2 x 0 = 0 2 x 0.063 = 0.126 SBUS+18 1 6860 36'0.00777 1 x 0.027 = 0.027 1 x 0.053 = 0.053 SECONDARY POWER SOURCE REQUIREMENTS REQUIRED STANDBY TIME = 24 HOURS PROVIDE (2) 12V 12AH BATTERIES @ 24VDC REQUIRED ALARM TIME = 15 MINUTES SECONDARY STANDBY LOAD 0.231895 x 24 = 5.57 AH SECONDARY ALARM LOAD 1.883795 x 0.25 = 0.47 AH STANDBY AND ALARM LOAD SUBTOTAL 6.04 AH DERATING FACTOR x 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS)7.24 AH AOM S H 135 FT AIM S F AOM FAA F1 N1 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0.39 Min. Operational Voltage:16 End Of Line Voltage:20.01 Max. Circuit Current (A):3 Voltage Drop Percent:1.89 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.268 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):234 Spare Current (A):2.732 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):1.438083 Spare Current (A) Percent:91.07 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 95cd 2 0.134 0.268 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) F1 N2 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0.42 Min. Operational Voltage:16 End Of Line Voltage:19.98 Max. Circuit Current (A):3 Voltage Drop Percent:2.06 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.275 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):248 Spare Current (A):2.725 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):1.525768 Spare Current (A) Percent:90.83 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 4 0.041 0.164 SPSCWL Speaker/Strobe Ceiling Mount, White 75cd 1 0.111 0.111 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) F1 N3 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:1.24 Min. Operational Voltage:16 End Of Line Voltage:19.16 Max. Circuit Current (A):3 Voltage Drop Percent:6.06 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.451 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):447 Spare Current (A):2.549 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):2.743053 Spare Current (A) Percent:84.97 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 11 0.041 0.451 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) F1 N4 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:1.13 Min. Operational Voltage:16 End Of Line Voltage:19.27 Max. Circuit Current (A):3 Voltage Drop Percent:5.53 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.372 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):494 Spare Current (A):2.628 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):3.033475 Spare Current (A) Percent:87.60 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 6 0.041 0.246 SPSCWL Speaker/Strobe Ceiling Mount, White 30cd 2 0.063 0.126 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-601 CALCULATIONS HI B B A R D E L E M E N T A R Y SC H O O L PANEL LOAD SUMMARY STANDBY CURRENT (AMPS)ALARM CURRENT (AMPS) PANEL P1 (SK-PS10) SUMMARY REPORT PANEL COMPONENT SUMMARY QTY PART NO DESCRIPTION CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL 1 SK-PS10 Main Board Main Board 1 x 0.156 = 0.156 1 x 0.185 = 0.185 CIRCUIT SUMMARY CIRCUIT N1 1 x 0 = 0 1 x 0.93 = 0.93 N2 1 x 0 = 0 1 x 1.061 = 1.061 N3 1 x 0 = 0 1 x 0.536 = 0.536 N4 1 x 0 = 0 1 x 0.664 = 0.664 N5 1 x 0 = 0 1 x 0.928 = 0.928 N6 1 x 0 = 0 1 x 1.024 = 1.024 TOTAL STANDBY CURRENT 0.156 TOTAL ALARM CURRENT 5.328 CIRCUIT DETAILS AND CALCULATIONS STANDBY CURRENT ALARM CURRENT SOURCE CIRCUIT AWG SYMBOL QTY PART NO DEVICE SETTING CIRCUIT LENGTH CIRCUIT RESISTANCE (Ω/ft) CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL (A) SK-PS10 Main Board N1 14 6 SPSCWL 15cd 421'0.00307 6 x 0 = 0 6 x 0.041 = 0.246 1 SPSCWL 15cd 1 x 0 = 0 1 x 0.06 = 0.06 2 SPSCWL 30cd 2 x 0 = 0 2 x 0.063 = 0.126 2 SPSCWL 30cd 2 x 0 = 0 2 x 0.086 = 0.172 1 SPSCWL 75cd 1 x 0 = 0 1 x 0.111 = 0.111 5 SRL 15cd 5 x 0 = 0 5 x 0.043 = 0.215 N2 14 1 P2RK 75cd 450'0.00307 1 x 0 = 0 1 x 0.176 = 0.176 1 SPSCWL 15cd 1 x 0 = 0 1 x 0.041 = 0.041 2 SPSCWL 75cd 2 x 0 = 0 2 x 0.111 = 0.222 4 SPSCWL 95cd 4 x 0 = 0 4 x 0.134 = 0.536 2 SRL 15cd 2 x 0 = 0 2 x 0.043 = 0.086 N3 14 4 SPSCWL 95cd 257'0.00307 4 x 0 = 0 4 x 0.134 = 0.536 N4 14 1 P2RK 75cd 469'0.00307 1 x 0 = 0 1 x 0.176 = 0.176 2 SPSCWL 15cd 2 x 0 = 0 2 x 0.041 = 0.082 1 SPSCWL 30cd 1 x 0 = 0 1 x 0.063 = 0.063 1 SPSCWL 75cd 1 x 0 = 0 1 x 0.111 = 0.111 1 SPSRL 30cd 1 x 0 = 0 1 x 0.063 = 0.063 1 SPSRL 30cd 1 x 0 = 0 1 x 0.083 = 0.083 2 SRL 15cd 2 x 0 = 0 2 x 0.043 = 0.086 N5 14 7 SPSCWL 15cd 433'0.00307 7 x 0 = 0 7 x 0.041 = 0.287 5 SPSCWL 75cd 5 x 0 = 0 5 x 0.111 = 0.555 2 SRL 15cd 2 x 0 = 0 2 x 0.043 = 0.086 N6 14 1 P2RK 75cd 465'0.00307 1 x 0 = 0 1 x 0.176 = 0.176 5 SPSCWL 15cd 5 x 0 = 0 5 x 0.041 = 0.205 6 SPSCWL 30cd 6 x 0 = 0 6 x 0.063 = 0.378 2 SPSCWL 75cd 2 x 0 = 0 2 x 0.111 = 0.222 1 SRL 15cd 1 x 0 = 0 1 x 0.043 = 0.043 SECONDARY POWER SOURCE REQUIREMENTS REQUIRED STANDBY TIME = 24 HOURS PROVIDE (2) 12V 7AH BATTERIES @ 24VDC REQUIRED ALARM TIME = 15 MINUTES SECONDARY STANDBY LOAD 0.156 x 24 = 3.74 AH SECONDARY ALARM LOAD 5.328 x 0.25 = 1.33 AH STANDBY AND ALARM LOAD SUBTOTAL 5.08 AH DERATING FACTOR x 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS)6.09 AH P1 N1 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:2.4 Min. Operational Voltage:16 End Of Line Voltage:18 Max. Circuit Current (A):3 Voltage Drop Percent:11.78 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.93 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):421 Spare Current (A):2.07 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):2.584467 Spare Current (A) Percent:69.00 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 6 0.041 0.246 SRL Strobe, Red 15cd 5 0.043 0.215 SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 1 0.06 0.06 SPSCWL Speaker/Strobe Ceiling Mount, White 30cd 2 0.063 0.126 SPSCWL Speaker/Strobe Ceiling Mount, White 30cd 2 0.086 0.172 SPSCWL Speaker/Strobe Ceiling Mount, White 75cd 1 0.111 0.111 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) P1 N2 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:2.93 Min. Operational Voltage:16 End Of Line Voltage:17.47 Max. Circuit Current (A):3 Voltage Drop Percent:14.36 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):1.061 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):450 Spare Current (A):1.939 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):2.761023 Spare Current (A) Percent:64.63 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 1 0.041 0.041 SRL Strobe, Red 15cd 2 0.043 0.086 SPSCWL Speaker/Strobe Ceiling Mount, White 75cd 2 0.111 0.222 SPSCWL Speaker/Strobe Ceiling Mount, White 95cd 4 0.134 0.536 P2RK 2-Wire Horn Strobe, Standard cd, Outdoor 75cd 1 0.176 0.176 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) WP P1 N3 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0.85 Min. Operational Voltage:16 End Of Line Voltage:19.55 Max. Circuit Current (A):3 Voltage Drop Percent:4.15 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.536 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):257 Spare Current (A):2.464 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):1.579933 Spare Current (A) Percent:82.13 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 95cd 4 0.134 0.536 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) P1 N4 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:1.91 Min. Operational Voltage:16 End Of Line Voltage:18.49 Max. Circuit Current (A):3 Voltage Drop Percent:9.38 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.664 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):469 Spare Current (A):2.336 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):2.881021 Spare Current (A) Percent:77.87 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 2 0.041 0.082 SRL Strobe, Red 15cd 2 0.043 0.086 SPSCWL Speaker/Strobe Ceiling Mount, White 30cd 1 0.063 0.063 SPSRL Speaker/Strobe Wall Mount, Red 30cd 1 0.063 0.063 SPSRL Speaker/Strobe Wall Mount, Red 30cd 1 0.083 0.083 SPSCWL Speaker/Strobe Ceiling Mount, White 75cd 1 0.111 0.111 P2RK 2-Wire Horn Strobe, Standard cd, Outdoor 75cd 1 0.176 0.176 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) WP P1 N5 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:2.47 Min. Operational Voltage:16 End Of Line Voltage:17.93 Max. Circuit Current (A):3 Voltage Drop Percent:12.08 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.928 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):433 Spare Current (A):2.072 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):2.65633 Spare Current (A) Percent:69.07 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 7 0.041 0.287 SRL Strobe, Red 15cd 2 0.043 0.086 SPSCWL Speaker/Strobe Ceiling Mount, White 75cd 5 0.111 0.555 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) P1 N6 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:2.93 Min. Operational Voltage:16 End Of Line Voltage:17.47 Max. Circuit Current (A):3 Voltage Drop Percent:14.34 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):1.024 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):465 Spare Current (A):1.976 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):2.857568 Spare Current (A) Percent:65.87 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 5 0.041 0.205 SRL Strobe, Red 15cd 1 0.043 0.043 SPSCWL Speaker/Strobe Ceiling Mount, White 30cd 6 0.063 0.378 SPSCWL Speaker/Strobe Ceiling Mount, White 75cd 2 0.111 0.222 P2RK 2-Wire Horn Strobe, Standard cd, Outdoor 75cd 1 0.176 0.176 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) WP SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-602 CALCULATIONS HI B B A R D E L E M E N T A R Y SC H O O L PANEL LOAD SUMMARY STANDBY CURRENT (AMPS)ALARM CURRENT (AMPS) PANEL P2 (SK-PS10) SUMMARY REPORT PANEL COMPONENT SUMMARY QTY PART NO DESCRIPTION CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL 1 SK-PS10 Main Board Main Board 1 x 0.156 = 0.156 1 x 0.185 = 0.185 CIRCUIT SUMMARY CIRCUIT AUX1 1 x 0 = 0 1 x 0 = 0 AUX2 1 x 0 = 0 1 x 0 = 0 N1 1 x 0 = 0 1 x 1.011 = 1.011 N2 1 x 0 = 0 1 x 0.883 = 0.883 N3 1 x 0 = 0 1 x 1.035 = 1.035 N4 1 x 0 = 0 1 x 0.473 = 0.473 TOTAL STANDBY CURRENT 0.156 TOTAL ALARM CURRENT 3.587 CIRCUIT DETAILS AND CALCULATIONS STANDBY CURRENT ALARM CURRENT SOURCE CIRCUIT AWG SYMBOL QTY PART NO DEVICE SETTING CIRCUIT LENGTH CIRCUIT RESISTANCE (Ω/ft) CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL (A) SK-PS10 Main Board N1 14 6 SPSCWL 15cd 430'0.00307 6 x 0 = 0 6 x 0.041 = 0.246 3 SPSCWL 30cd 3 x 0 = 0 3 x 0.086 = 0.258 4 SPSCWL 75cd 4 x 0 = 0 4 x 0.111 = 0.444 1 SPSRL 30cd 1 x 0 = 0 1 x 0.063 = 0.063 N2 14 1 P2RK 75cd 457'0.00307 1 x 0 = 0 1 x 0.176 = 0.176 1 SPSCWL 15cd 1 x 0 = 0 1 x 0.041 = 0.041 6 SPSCWL 75cd 6 x 0 = 0 6 x 0.111 = 0.666 N3 14 1 P2RK 75cd 542'0.00307 1 x 0 = 0 1 x 0.176 = 0.176 2 SPSCWL 15cd 2 x 0 = 0 2 x 0.041 = 0.082 7 SPSCWL 75cd 7 x 0 = 0 7 x 0.111 = 0.777 N4 14 2 SPSCWL 15cd 244'0.00307 2 x 0 = 0 2 x 0.041 = 0.082 2 SPSCWL 30cd 2 x 0 = 0 2 x 0.063 = 0.126 2 SPSCWL 75cd 2 x 0 = 0 2 x 0.111 = 0.222 1 SRL 15cd 1 x 0 = 0 1 x 0.043 = 0.043 SECONDARY POWER SOURCE REQUIREMENTS REQUIRED STANDBY TIME = 24 HOURS PROVIDE (2) 12V 7AH BATTERIES @ 24VDC REQUIRED ALARM TIME = 15 MINUTES SECONDARY STANDBY LOAD 0.156 x 24 = 3.74 AH SECONDARY ALARM LOAD 3.587 x 0.25 = 0.9 AH STANDBY AND ALARM LOAD SUBTOTAL 4.64 AH DERATING FACTOR x 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS)5.57 AH WP P2 AUX1 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0 Min. Operational Voltage:16 End Of Line Voltage:20.4 Max. Circuit Current (A):3 Voltage Drop Percent:0.00 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0 Circuit Wiring Properties: 'P' 14/2 FPLP/R (AUX) 14 AWG, 2 Cond. Solid Copper FPLP/R Unshielded Total Circuit Length (Ft):244 Spare Current (A):3 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):1.49839 Spare Current (A) Percent:100.00 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) FM998 24V Door Holder 7 0 0 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) DH P2 AUX2 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0 Min. Operational Voltage:16 End Of Line Voltage:20.4 Max. Circuit Current (A):3 Voltage Drop Percent:0.00 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0 Circuit Wiring Properties: 'P' 14/2 FPLP/R (AUX) 14 AWG, 2 Cond. Solid Copper FPLP/R Unshielded Total Circuit Length (Ft):372 Spare Current (A):3 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):2.282437 Spare Current (A) Percent:100.00 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) FM998 24V Door Holder 4 0 0 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) DH P2 N1 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:2.67 Min. Operational Voltage:16 End Of Line Voltage:17.73 Max. Circuit Current (A):3 Voltage Drop Percent:13.09 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):1.011 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):430 Spare Current (A):1.989 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):2.641824 Spare Current (A) Percent:66.30 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 6 0.041 0.246 SPSRL Speaker/Strobe Wall Mount, Red 30cd 1 0.063 0.063 SPSCWL Speaker/Strobe Ceiling Mount, White 30cd 3 0.086 0.258 SPSCWL Speaker/Strobe Ceiling Mount, White 75cd 4 0.111 0.444 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) P2 N2 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:2.48 Min. Operational Voltage:16 End Of Line Voltage:17.92 Max. Circuit Current (A):3 Voltage Drop Percent:12.14 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.883 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):457 Spare Current (A):2.117 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):2.803912 Spare Current (A) Percent:70.57 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 1 0.041 0.041 SPSCWL Speaker/Strobe Ceiling Mount, White 75cd 6 0.111 0.666 P2RK 2-Wire Horn Strobe, Standard cd, Outdoor 75cd 1 0.176 0.176 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) WP P2 N3 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:3.44 Min. Operational Voltage:16 End Of Line Voltage:16.96 Max. Circuit Current (A):3 Voltage Drop Percent:16.88 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):1.035 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):542 Spare Current (A):1.965 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):3.326709 Spare Current (A) Percent:65.50 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 2 0.041 0.082 SPSCWL Speaker/Strobe Ceiling Mount, White 75cd 7 0.111 0.777 P2RK 2-Wire Horn Strobe, Standard cd, Outdoor 75cd 1 0.176 0.176 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) WP P2 N4 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0.71 Min. Operational Voltage:16 End Of Line Voltage:19.69 Max. Circuit Current (A):3 Voltage Drop Percent:3.48 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.473 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):244 Spare Current (A):2.527 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):1.499756 Spare Current (A) Percent:84.23 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SPSCWL Speaker/Strobe Ceiling Mount, White 15cd 2 0.041 0.082 SRL Strobe, Red 15cd 1 0.043 0.043 SPSCWL Speaker/Strobe Ceiling Mount, White 30cd 2 0.063 0.126 SPSCWL Speaker/Strobe Ceiling Mount, White 75cd 2 0.111 0.222 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-603 CALCULATIONS HI B B A R D E L E M E N T A R Y SC H O O L SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l TE T O N S M A R T S E C U R I T Y 29 8 1 S T S T . ID A H O F A L L S , I D 8 3 4 0 1 NICET Information: Christen F. Camplain NICET Cert. No. 113030 Fire Alarm Systems - Level IV Cert. Expires: March 1, 2026 MP CODE 6/10/23 FIRE ALARM SYSTEM HI B B A R D E L E M E N T A R Y RE X B U R G , I D A H O FA-701 WIRING TYPICALS HI B B A R D E L E M E N T A R Y SC H O O L DEVICE MOUNTING HEIGHT REFERENCE PER NFPA 72 SIDE WALL CEILING VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS 1.MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO TOP OF LENS FOR 110CD STROBES WITHIN 16' OF THE PILLOW 2.177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24" (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. AUDIBLE ONLYAUDIBLE/VISUAL & VISUAL ONLY APPLIANCES SYNCHRONIZE MORE THAN TWO APPLIANCES IN ANY FIELD OF VIEW. NOTE: REFER TO THE PROPER DEVICE INSTALLATION INSTRUCTIONS FOR BACKBOX MOUNTING HEIGHT. NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST EDGE OF THE DETECTOR. THE 4" REQUIREMENT FOR SMOKE DETECTORS HAS BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 CEILING MOUNTED SMOKE/HEAT DETECTOR ACCEPTED HERE HEAT DETECTORS NEVER HERE WALL MOUNTED SMOKE/HEAT DETECTOR 4" (102mm) 4" (102mm)3' (914mm) MINIMUM A/C SUPPLY OR RETURN DIFFUSER FINISHED FLOOR F I R E MAGNETIC DOOR HOLDER FIRE PHONE JACK FOR CEILING HEIGHTS LESS THAN 86" (2180mm), THE VISUAL LENS MOUNTING HEIGHT SHALL BE WITHIN 6" (150mm) OF THE CEILING. 96" MAX (ADA, IBC, NFPA) (2440mm MAX) ABOVE FINISHED FLOOR TO TOP OF LENS 48" MAX (ADA) (1219mm) 48" MAX (NFPA, ADA) (1219mm MAX) 42" MIN (NFPA) (1067mm MIN) MEASUREMENTS SHOWN ARE TO TOP OF PULL HANDLE MANUAL PULL STATION TO EXIT DOOR 5' (MAX.) (1524mm) DOOR WIDTH LESS 3" (76mm) 5" (127mm)90" MIN (2286mm MIN) ABOVE FINISHED FLOOR (OTHER MOUNTING HEIGHTS SHALL BE PERMITTED BY THE AHJ PROVIDING IT MEETS THE SOUND LEVEL OUTPUT REQUIRED.) NFPA 72 AUDIBLE APPLIANCE 6" MIN (152.4mm MIN) BELOW FINISHED CEILING F I R E FINISHED WALL 12" (305mm) MAXIMUM TO TOP OF SENSOR 80" MIN (ADA, IBC, NFPA) (2032mm MIN) ABOVE FINISHED FLOOR TO BOTTOM OF LENS REMOTE POWER SUPPLY SILENT KNIGHT SK-PS10 AC1 AC2 TB4 TB15 TB3 TB2 TB1 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 1'-23 4" 1'-83 8" 3 5 16" BATTERY BATTERY Refer to Battery Charts for Correct Size Refer to Battery Charts for Correct Size (+)(-)(+)(-) FORM-C RELAYS Non-supervisedAC1 (Hot) Earth AC2 (Nuetral) TB4 AC POWER Supervised, Non-power-limited Output Status LEDs Trouble (yellow) Power (red) NAC/Out 1 + NAC/Out 1 - NAC/Out 2 + NAC/Out 2 - NAC/Out 3 + NAC/Out 3 - NAC/Out 4 + NAC/Out 4 - NAC/Out 5 + NAC/Out 5 - NAC/Out 6 + NAC/Out 6 - NAC/Out 7 + NAC/Out 7 - Power-limited (Class 2), Supervised, Special Application or Regulated Outputs J8 ZNAC-PS Connector EOL - + EOL Input #1 TB5, TB6, TB7 Command Inputs EOL - + EOL Input #2 EOL - + EOL Input #3 LEDs Power (green) Batt/Chgr (yellow) Ground Fault (yellow) TB15 Supervised Non-power-limited SW1 Ground Fault Detection ADDRESSABLE PULL STATION SILENT KNIGHT SK-PULL-DA Ratings Normal Operating Voltage: 24VDC. Average Operating Current (LED Flash): 300 µA. Temperature Range: 32°F - 120°F (0°C - 49°C). Relative Humidity Range: 10% - 93% non-condensing. Installation The SK-Pull-DA Addressable pull station can be surface mounted to a SB-I/O surface backbox or semi-flush mounted on a standard single-gang, double-gang or 4˝ (10.16 cm) square electrical box. The optional BG-TR trim ring can be used if the SK-Pull-DA is to be semi-flush mounted. Operation To activate the dual-action pull station, push in and pull down on the handle. The word `ACTIVATED' appears after the handle is pulled down. This will remain until the pull sta- tion is reset. The pull station includes one Single Pole, Single Throw (SPST) Normally Open (N/O) switch which closes upon activation of the pull station. Resetting the Pull Station 1.Insert the key into the lock and rotate 1/4 turn counterclockwise. 2.Open the door until the handle returns to normal. 3.Close and lock the door. SLCSLC STRIP GAUGE 1 2 3 4 From FACP To Next Addressable Device Note - Opening the pull station door will not activate or deactivate the alarm switch. NORM A L ACTIV ATED 0 0 10 11 12 1314 15 1 1 2 2 3 3 4 4 TENS ONES 6 67788995 5 LOOP FIRE ALARM BOX REFER TO DOCUMENT P/N 50997 REV-A M ADDRESS LU PRODUCT IDENTIFICATION LABEL 0 1 2 3 4 5 6 78 9 10 11 12 13 1514 ADDRESS LOOP 0 0 10 11 12 13 14 15 1 1 2 2 3 3 4 4 6 67788995 5 LED ROTARY ADDRESS SWITCHES LED OPERATION Alarm: Steady RED Normal: Flash GREEN Note: LED is visible through translucent handle. ADDRESSABLE MONITOR MODULE SILENT KNIGHT SK-MONITOR2 T1 T2 T3 T4 T5 T11 T10 T9 T8 T7 T6 ADDRESSABLE CONTROL MODULE SILENT KNIGHT SK-CONTROL T1 T2 T3 T4 T5 T11 T10 T9 T8 T7 T6 T1 T2 T3 T4 T5 T11 T10 T9 T8 T7 T6 ADDRESSABLE CONTROL MODULE SILENT KNIGHT SK-RELAY T1 T2 T3 T4 T5 T11 T10 T9 T8 T7 T6 T1 T2 T3 T4 T5 T11 T10 T9 T8 T7 T6 RELAY COMMON 2 NORMALLY CLOSED 2 NORMALLY OPEN 2 RELAY COMMON 1 NORMALLY CLOSED 1 ADDRESSABLE SMOKE SENSOR SILENT KNIGHT SK-DUCT Jumper J-1 must be cut to enable circuit board supervision of input AUX power and the SW-1 cover tamper switch. When J-1 is cut and either AUX power to the unit is lost for more than twenty minutes or the detector cover is removed for more than twenty minutes, the detector will send an invalid reply that will be displayed at the FACP. ADDRESSABLE SMOKE SENSOR SILENT KNIGHT SK-HEAT SENSOR WITH B210LP BASE ADDRESSABLE SMOKE SENSOR 3' (941mm) MIN.4" (102mm) CEILING MOUNTED SENSOR SENSORS NEVER HERE 12"(305mm) MAXIMUM TO TOP OF SENSOR FINISHED WALL WALL MOUNTED SENSOR SILENT KNIGHT SK-PHOTO SENSOR WITH B210LP BASE CONVENTIONAL NOTIFICATION APPLIANCES SYSTEM SENSOR P2RK SERIES WALL MOUNTED WEATHERPROOF AUDIBLE/VISUAL INPUT FROM POWER SOURCE OR PRIOR DEVICE OUTPUT TO NEXT DEVICE OR EOL WIRING DIAGRAM + - + - WIRING NOTES CONVENTIONAL APPLIANCES SYSTEM SENSOR SPSL SERIES WALL MOUNTED MULTI-CANDELA SPEAKER / VISUAL MOUNTING DETAIL 5. SEE FLOOR PLANS FOR QTY. & MODEL OF DEVICES/CKT. 4. WHEN USING SHIELDED CABLE, SPLICE DRAIN WIRE THRU AT EACH DEVICE AND INSULATE WITH TAPE. DO NOT GROUND DRAIN WIRE! TRIM FOIL EVEN WITH OUTER JACKET AND TAPE. 6 INCHES BELOW THE CEILING WHICHEVER HIGHEST FLOOR LEVEL WITHIN THE SPACE OR SHALL BE PLACED 80 INCHES ABOVE THE 3. ADA REQUIRES THAT INDICATING ALARM DEVICES 2. VERIFY CANDELA JUMPER CONFIGURATION PRIOR OF TERMINATIONS AND CIRCUIT CONTINUITY. BREAK WIRE RUN TO PROVIDE SUPERVISION 1. DO NOT LOOP WIRE UNDER TERMINALS. IS LOWER. TO INSTALLATION. INPUT FROM AMPLIFIER (-) (+) (-) (+)OUTPUT TO NEXT SPEAKER OR EOL (-) (+) (-) (+)OUTPUT TO NEXT STROBE OR EOLINPUT FROM POWER SUPPLY (-) (+) WIRING NOTES CONVENTIONAL APPLIANCES SYSTEM SENSOR SPSCL SERIES CEILING MOUNTED MULTI-CANDELA SPEAKER / VISUAL MOUNTING DETAIL 4. SEE FLOOR PLANS FOR QTY. & MODEL OF DEVICES/CKT. 3. WHEN USING SHIELDED CABLE, SPLICE DRAIN WIRE THRU AT EACH DEVICE AND INSULATE WITH TAPE. DO NOT GROUND DRAIN WIRE! TRIM FOIL EVEN WITH OUTER JACKET AND TAPE. 2. VERIFY CANDELA JUMPER CONFIGURATION PRIOR OF TERMINATIONS AND CIRCUIT CONTINUITY. BREAK WIRE RUN TO PROVIDE SUPERVISION 1. DO NOT LOOP WIRE UNDER TERMINALS. TO INSTALLATION. INPUT FROM AMPLIFIER (-) (+) (-) (+)OUTPUT TO NEXT SPEAKER OR EOL (-) (+) (-) (+)OUTPUT TO NEXT STROBE OR EOLINPUT FROM POWER SUPPLY (-) (+) CONVENTIONAL NOTIFICATION APPLIANCES TERMINATION VIEW: DEVICE BACKPLATE CLASS B WIRING SYSTEM SENSOR SR/WL SERIES WALL MOUNTED VISUAL 1.MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. 2.ALWAYS CUT CONDUCTORS AND SECURE UNDER TERMINALS. NEVER LOOP WIRES UNDER TERMINALS. 3.ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ APPROVED METHODS. WIRING NOTES MOUNTING OPTIONS OPTION DESCRIPTION NOTE A 4" (102mm) SQUARE BOX, 1-1/2" (38mm) DEEP (MIN)BY OTHERS B 4" OTAGONAL BACK BOX BY OTHERS C SINGLE-GANG, 3.5" (89mm) DEEP (MIN) - FLUSH MOUNT BY OTHERS D DOUBLE-GANG, 3.5" (89mm) DEEP (MIN) - FLUSH MOUNT BY OTHERS INPUT FROM FACP OR PRIOR DEVICE OUTPUT TO NEXT DEVICE OR EOL (+) (-) (+) (-)