Loading...
HomeMy WebLinkAboutFA SUBMITTAL - 22-00269 - Hibbard Elementary SchoolCUSTOMER LOGO (DELETE) Fire Alarm System Submittal For Hibbard Elementary School Rexburg, Idaho Teton Smart Security 298 1st Street Idaho Falls, ID 83401 Project Manager Martin Pelton Project Designer C+ June 10, 2023 Hibbard Elementary School 1 EQUIPMENT LIST Ta b l e o f C o n t e n t s 2 DATA SHEETS EQUIPMENT LIST Hibbard Elementary School Item Part #Quantity Manufacturer 1 6820EVS 1 SILENT KNIGHT FIRE ALARM CONTROL PANEL W/VOICE 2 SK-PS10 2 SILENT KNIGHT REMOTE POWER SUPPLY 3 6860 1 SILENT KNIGHT REMOTE ANNUNCIATOR 4 EVS-100W 1 SILENT KNIGHT AMPLIFIER 5 RTS151KEY 11 SYSTEM SENSOR REMOTE TEST SWITCH 6 SK-PULL-DA 1 SILENT KNIGHT MANUAL PULL STATION 7 SK-MONITOR 8 SILENT KNIGHT MONITOR MODULE 8 SK-CONTROL 1 SILENT KNIGHT NOTIFICATION CONTROL MODULE 9 SK-RELAY 14 SILENT KNIGHT RELAY MODULE 10 SK-DUCT 11 SILENT KNIGHT DUCT DETECTOR 11 SK-HEAT 1 SILENT KNIGHT HEAT DETECTOR 12 SK-PHOTO-W 25 SILENT KNIGHT ADDRESSABLE SMOKE DETECTOR 13 P2RK 5 SYSTEM SENSOR HORN/STROBE WP, RED 14 SPSRL 3 SYSTEM SENSOR WALL MT, SPEAKER/STROBE, RED 15 SPSCWL 113 SYSTEM SENSOR CLG MT, SPEAKER/STROBE, WHITE 16 SRL 13 SYSTEM SENSOR WALL MT, STROBE, RED 17 FM998 11 SYSTEM SENSOR 24V DOOR HOLDER 18 PS-1270 6 POWERSONIC 12V 7AH BATTERY 19 PS-12120 2 POWERSONIC 12V 12AH BATTERY 20 DTK-120HW 1 DITEK SURGE PROTECTOR 21 6120UL LOT BELDEN 14-2 TP NON-SHIELDED FPL CABLE 22 6220UL LOT BELDEN 16-2 TP NON-SHIELDED FPL CABLE 23 6320UL LOT BELDEN 18-2 TP NON-SHIELDED FPL CABLE 24 6320FK LOT BELDEN 18-2 TSP FPL CABLE Fire Alarm System Description Submittal Hibbard Elementary School Fire Alarm System Submittal DATA SHEETS 6820EVS Intelligent Fire Alarm Control Panel with Emergency Voice System The 6820EVS is an intelligent addressable Fire Alarm Control Panel combined with an Emergency Voice System (EVS) and are direct replacements for the 5820XL-EVS FACP. When the EVS features are enabled, they are integrated with the fire alarm and voice evacuation functions of the control panel. The emergency voice system operations include an onboard supervised microphone. All-call and non-active call buttons can quickly select all active or non-active output groups. The system also allows for emergency messages over fire. The 6820EVS FACP has one built-in signaling line circuit (SLC), which can support 159 SK detectors and 159 SK modules, or 127 SD protocol devices. Additional SLC loops can be added for a maximum of 1110 (SK) or 635 (SD) points per panel. The built-in digital alarm communicator/transmitter (DACT) is dual technology, IP and POTS. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator’s internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available. The 6820EVS has six onboard Flexput® circuits that can be configured as notification outputs or auxiliary power. The 6820EVS also has a form-C trouble relay, and two programmable form-C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and a calibration trouble alert. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. FEATURES AND BENEFITS • Single enclosure for both fire and emergency voice components • Ability to select EVS messages as priority over fire • 15 Recordable one-minute messages that can be mapped to eight EVS buttons • Capable of producing 520 Hz tones to meet NFPA 72 requirements • Support for up to 4 LOC consoles and 8 addressable amplifiers • Expandable SLC loops to 1110 (SK) or 635 (SD) point capacity • Six Flexput circuits for NAC outputs or auxiliary power • Selectable strobe synchronization for Amseco®, System Sensor®, Wheelock®, and Gentex® devices • Built-in DACT with IP and optional cellular reporting • Built-in USB interface for quick and easy programming • JumpStart® auto programming reduces installation time • 999 software zones & 999 output groups for flexible design options • 23 preset notification cadence patterns (including ANSI® 3.41) • Allows up to 24 SBUS devices • Four programmable function keys • Two programmable relays and one fixed trouble relay • Compatible with SWIFT® wireless devices • Convenient field-upgradeable firmware • Network support for up to 17 sites • Network card allows copper network connection with a multi-mode or single- mode fiber connection • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity The 6820EVS panels and accessories provide features to meet the requirements for Mass Notification Systems as described in UL 2572 2nd Edition and UL 864 10th Edition. Page 2 of 4 — 351606:E • 3/7/2022 USER INTERFACE LED INDICATORS • General Alarm (Red) • Supervisory (Yellow) • System Trouble (Yellow) • System Silenced (Yellow • System Power (Green) KEYPAD • 12-key numeric pad •Acknowledge • Alarm Silence •System Reset •Drill • F1-F4 Programmable Function Keys PROGRAMMING The 6820EVS system offers several options to simplify and expedite programming. JumpStart® auto programming minimizes programming required to start a new system. The built-in keypad, or the remote annunciators give on-site access to current system programming. System programming can also be accomplished using the Windows®-based Honeywell Fire Software Suite (HFSS). ORDERING INFORMATION 6820EVS: Addressable fire alarm control panel with emergency voice system, red COMPATIBLE EVS EQUIPMENT EVS-50W: 50 Watt amplifier EVS-125W: 125 Watt amplifier EVS-100W: 50/100 Watt amplifier EVS-100WBU: External backup amplifier EVS-INT50W: 50 /Watt internal amplifier EVS-CE4: Provides 4 additional audio circuits EVS-RVM: Remote voice module EVS-SW24: 24 switch expander EVS-VCM: Network voice control module EVS-LOC: Local operator console COMPATIBLE SBUS DEVICES 6860: 4x40 LCD remote fire annunciator with four programmable buttons, red 5860: 4x20 LCD remote fire annunciator, gray 5860R: 4x20 LCD remote fire annunciator, red 6855: 4x20 LCD remote fire annunciator, red 5865-3: LED annunciators- display up to 30 LEDs (15 red/15 yellow) 5865-4: LED annunciators- display up to 30 LEDs (15 red/15 yellow). Key switches for silence and reset, and a system trouble LED 5880: LED I/O module with 40 programmable LED outputs and eight supervised dry contact inputs 5883: Relay interface. Provides 10 Form C relays 5824: Serial/Parallel printer interface module for printer connection SK COMPATIBLE ADDRESSABLE DEVICES Note: SKand SD devices cannot be mixed in the same fire alarm system. SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature OSI-RI-SK: Reflected beam smoke detector, SK protocol SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-FIRE-CO-W: Four criteria fire and carbon monoxide detector, white SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-HEAT-ROR: Fixed rate of rise detector SK-HEAT-HT: Fixed high temperature heat detector (190°F) SK-HEAT-HT-W: Fixed high temperature heat detector (190°F), white SK-HEAT-ROR-W: Fixed rate of rise detector, white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10- input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-R: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PHOTO-T: Photoelectric smoke detector with fixed heat (135°F) SK-PHOTO-T-W: Photoelectric smoke detector with fixed thermal heat (135°F), white SK-PTIR-W: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature, white SK-PULL-SA Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module 351606:E • 3/7/2022 — Page 3 of 4 SK BASES B210LP: 6" mounting base B501: 4" Flangeless mounting base B200S: Intelligent sounder base B200S-LF: Low-frequency intelligent sounder base B224RB: Relay base B224BI: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES Note: SK and SD devices cannot be mixed in the same fire alarm system. SD505-6AB: Addressable 6" base SD505-6IB: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch/LED indicator for the SD505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector SD505-DUCTR: Addressable Duct Detector housing with relay base SD505-HEAT: Absolute temperature heat detector. Trip point range from 135°F–150°F (0°C–37°C) SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module SWIFT WIRELESS DEVICES Note: SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless gateway WSK-PHOTO: Wireless photoelectric smoke detector with B501W base WSK-PHOTO-T: Wireless photoelectric smoke detector with fixed thermal detection (135°F) and B501W base W-SYNC: Wireless sync module WSK-HEAT: Wireless, fixed heat detector (135°F) with B501W base WSK-HEAT-ROR: Wireless rate-of-rise heat detector and B501W base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module WSK-PULL-DA: Wireless pull station WAV-RL, WAV-WL, WAV-CRL, WAV-CWL: Wireless AV bases W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools SWIFT Tools: Programming and diagnostic utility for the wireless gateway and devices. Available for download from www.farenhyt.com SYSTEM EXPANDERS 6815: SLC Expander for IDP or SK devices 5815XL: SLC expander for SD devices RPS-1000: 6A power supply with 6 Flexput circuits & 2 Form C relays 5496: 6 amp NAC power expander with 4 power-limited output ckts OPTIONAL COMMUNICATORS CELL-CAB-SK: Cellular communicator, metal enclosure w/lock & key CELL-MOD: Cellular communicator, plastic enclosure IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP -2: Remote reporting via the Internet. Requires a VisorALARM® receiver at the central station MISCELLANEOUS ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the IFP-300 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode RBB: Remote battery box accessory cabinet SK-SCK: Seismic compliance kit used to fasten batteries to the fire panel SOFTWARE SOLUTIONS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows®-based software system configuration tool to create a detailed bill of material (BOM) and battery calculations HFSS: Honeywell Fire Software Suite provides remote and local panel programming, detector status, event history and additional data. Databases can be uploaded/downloaded via the panel’s USB port using a flash drive. Requires a PC running Microsoft® Windows®. 6820EVS TECHNICAL SPECIFICATIONS 351606 | E | 04/22 ©2022 Honeywell International Inc. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com Flexput®, Honeywell®, JumpStart®, Silent Knight®, SWIFT®, and System Sensor® are registered trademarks of Honeywell International Inc. Amseco® is a registered trademark of Potter Electric Signal Company, LLC. Gentex® is a registered trademark of Gentex Corporation. Hochiki® is a registered trademark of Hochiki Corporation. Wheelock® is a trademark of Cooper Technologies Company. ANSI® is a registered trademark of the American National Standards Institute, Inc. VisorALARM® is a registered trademark of the Teldat Corporation. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: USA SYSTEM CAPACITY Intelligent Signaling Line Circuits: 1 (expandable) Addressable device capacity: 1110 (SK) or 635 (SD) Programmable software zones: 999 Output circuits: 6 (expandable) SBUS devices: 24 (16 annunciators, 8 LED modules) LOC units: 4 Addressable amplifiers (total watts): 8 (1000) ELECTRICAL AC Power: 120VAC, 60Hz, 3.3A Standby Current: 190 mA Alarm Current: 250 mA Flexput Circuits: Terminal block provides connections for (six Class B or three Class A) NACs or auxiliary power. Power-limited, supervised circuitry. Maximum current per circuit: 3 A. Cannot exceed 6A total for all circuits. End-of-line resistor: 4.7k ohm, ½ watt for Class B NACs Communication Loop: Supervised and power-limited, Class A or Class B, 32VDC, 150mA Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.5 A @ 27.4 VDC (resistive), Form C Battery: Cabinet holds maximum of two 18 AH batteries Battery Charger Capacity: 7-35 AH PHYSICAL Dimensions: 21.6” W x 28.1” H x 5.1” D (54.9cm W x 71.4cm H x 13.0cm D) Weight: 50 lbs. (22.7 kg.) Color: Red TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C (32– 120°F) and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27° C/60 – 80°F. STANDARDS AND CODES The 6820 complies with the following standards and codes: NFPA 72 NFPA 13 NFPA 15 NFPA 16 NFPA 70 UL 864 10th Edition UL2572 2nd Edition Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signaling services AGENCY LISTINGS AND APPROVALS UL Listed: S2766 CSFM: 7165-0559:0500 FDNY: COA# 6249 FM: Approved Seismic: (CA) VMA-45894-05C: SK-PS6 / SK-PS10 6 Amp and 10 Amp, 24 Volt Power Supplies The PS Series is a remote power supply line from Silent Knight and is a direct replacement for the 5495/5499. The SK-PS6 is a 6 amp and the SK-PS10 is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notification appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS • Up to five (6 amp model) or seven (10 amp model) independently-configurable, power- limited output circuits for: –Class B and/or Class A NACs –Class B and/or Class A resettable or non- resettable 24V auxiliary power –door holder power • Converts from Class B to Class A wiring without losing any outputs using the ZNAC- PS converter card (sold separately) • Optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Optional addressable control, monitor, and relay modules and power-supervision relay (EOLR-1) • Configurable for ANSI® Temporal 3 or Temporal 4 coded output • UL-Listed NAC synchronization using System Sensor®, Wheelock®, Gentex®, or AMSECO® appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) or three (10 amp model) fully-isolated input/control circuits which can be programmed to any output • Two Form C normally-closed trouble relays for AC Trouble and General Trouble • 6 or 10 amp full load output, respectively, with 3 A maximum/circuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history mode for diagnostic support • Wide range end-of-line supervision value (normal: 2-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra software required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion-resistant powder coat chip and scratch-resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire • Works with any UL 864 FACP which utilizes an industry-standard reverse-polarity notification circuit The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. Page 2 of 3 — SK-61095:C • 3/10/2021 ORDERING INFORMATION SK-PS6: 6.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red SK-PS10: 10.0 A, 120 VAC remote charger power supply in a lockable, metal enclosure, red ZNAC-PS: Optional Class A converter card, sold separately SK-CONTROL: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. SK-RELAY: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch SK-MONITOR: Addressable Monitor Module for one zone of normally open dry-contact initiating devices. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Class B or Class A SK-MONITOR-2: Dual Monitor Module. Same as SK-MONITOR except it provides two inputs for Class B wiring only SK-RELAYMON-2: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only SK-CONTROL-6: Six-circuit supervised control module SK-RELAY-6: Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required) BAT-12180-BP: Battery, 12 volt, 18AH, 2-pack BAT-12330: Battery, 12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. SK-PS6 / SK-PS10 TECHNICAL SPECIFICATIONS SK-61095 | C | 03/21 ©2021 Honeywell International Inc. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com Silent Knight® and System Sensor® are registered trademarks of Honeywell International, Inc. Wheelock® is a registered trademark of Cooper Technologies Company. Gentex® is a registered trademark of Gentex Corporation. AMSECO® is a registered trademark of Potter Electric Signal Company, LLC. ANSI® is a registered trademark of the American National Standards Institute, Inc. ©2021 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: USA PRIMARY (AC) POWER SK-PS6: 120 VAC, 50/60 Hz, 5.0A maximum SK-PS10: 120VAC, 50/60 Hz, 6.2 A maximum Wire Size: #12-14 AWG with 600 V insulation COMMAND INPUT CIRCUIT Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V) RELAY CIRCUITS Trouble Contact Rating: 4 A at 24 VDC OUTPUT CIRCUITS • 24 VDC filtered • SK-PS6: TB8-TB9 – 1A Regulated, 3A special applications; TB10-TB12 – 0.3A Regulated, 3A special applications • SK-PS10: TB8-TB11 – 1.5A Regulated, 3A special applications; TB12-TB14 – 0.3A Regulated, 3A special applications • 6.0 A (SK-PS6) or 10.0 (SK-PS10) maximum total continuous current for all outputs SECONDARY POWER (BATTERY) CHARGING CIRCUIT • Supports lead-acid batteries only • Float-charge voltage: 27.6 VDC • Maximum current charge: 1.5 A • Maximum battery capacity: 18 AH (inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) PHYSICAL Dimensions: 20.0”H x 14.5”W x 3.5”D (cm: 50.8H x 36.83W x 8.9D) Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) STANDARDS AND CODES The SK-PS complies with the following standards: NFPA 72: National Fire Alarm Code UL 864: Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481: Power Supplies for Fire Alarm Systems AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S3511 CSFM: 7315-0559:0522 FDNY Approved FM Approved 6860 Remote Annunciator The 6860 remote annunciator can be used to operate and program the Honeywell Silent Knight Series FACPs. The 6860 is shipped in a locked, key controlled cabinet, combining security with easy access. It does not require a code or firefighter's key to silence or reset a panel. In addition, it is designed with convenient separate scroll buttons to be used for alarm, supervisory and trouble conditions. The remote annunciator communicates with the main fire alarm control panel through an RS- 485 connection. The 6860 can be surface- or flush-mounted . COMPATIBILITY The 6860 is compatible with the following Honeywell Silent Knight Series FACPs: •6820: Addressable fire alarm control panel with up to 1,110 addressable points • 6820EVS: Addressable fire alarm control panel with an emergency voice system, up to 1,110 addressable points • 6700 Addressable fire alarm control panel with up to 100 addressable points • 6808 Addressable fire alarm control panel with up to 198 addressable points FEATURES AND BENEFITS • Complies with UL 864 10th and UL 2572 2nd Edition Standards • Complies with NFPA 72 • Features a four-line LCD display with 40 characters per line • Designed with a tactile/audible feedback when the key is pressed on the annunciator • Has an RS-485 SBUS interface to panel • Initiate and end fire drills with a single key • Can be flush- or surface-mounted • Trim ring (P/N: RA-100TR) available for surface-mounting • Support for simultaneous use of multiple 6860s • Provides onboard piezo sounder to broadcast audio alarms, troubles, and supervisories • Uses the following five status LEDs: - alarm - supervisory - trouble - silence - AC power indications • Includes four programmable function keys • Accommodates wiring lengths up to 6,000 ft. from the control panel • View current status by alarms, supervisories, or troubles The 6860 remote annunciator is used with the Silent Knight control panels. The 6860 features a large, 4 x 40 display and four programmable buttons. These features provide more options for set-up and operation when compared to similar remote annunciators. 6860 TECHNICAL SPECIFICATIONS 351612 | B | 04-22 ©2022 Honeywell International Inc. Honeywell®and Silent Knight are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: U.S.A. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.silentknight.com PHYSICAL Flush Mount: Outside wall: 12.25”W x 11.05”H x .875”D (31.01W x 29.02H x 2.02D cm) Inside wall: 9.375”W x 8.375”H x 2.0”D (23.08W x 21.03H x 5.01D cm) Surface Mount: (Including Trim Ring) 12.25”W x 11.05”H x 3.0”D (31.01W x 29.02H x 2.02D cm) ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 0 to 93% relative humidity (non-condensing) ELECTRICAL. Operating Voltage: 24VDC Standby Current: 27mA Alarm Current: 53mA ORDERING INFORMATION 6860: Remote Annunciator, red OPTIONAL ACCESSORIES RA-100TR: Red surface mount trim ring RA-100TG: Gray surface mount trim ring STANDARDS AND CODES The 6860 complies with the following standards and codes. • UL 864, 10th Edition: Standard for Control Units for Fire Alarm Systems • UL 2572, 2nd Edition: Standard for Mass Notification Systems •NFPA 72 AGENCY LISTINGS AND APPROVALS •UL Listed: S3511 •CSFM Approved •FDNY Approved The EVS-100W is an intelligent 50/100 watt amplifier for use with Version 14.0 or newer 5820XL-EVS. The EVS-100W is used to amplify audio message for distribution throughout a facility. The EVS-100W is capable ofproducing up to 100 watts of audio power and has the ability to provide an option for 50 watts of backup power.For more information about the EVS-100W, or to locate your nearest source, please call 800-328-0103. IntelliKnight®Model EVS-100W Intelligent 50/100 Watt Amplifier withoptional Backup Amplifier INTELLIGENT AMPLIFIER Model EVS-100W DescriptionThe EVS-100W has its own power supply with battery backupand eight speaker circuits. The EVS-100W is fully supervisedby the main panel for trouble conditions. Features•Amplifier Configurations:• 50 watts with 50 watts as backup.• 100 watt single channel.• 100 watt single channel with 50 watts backup using EVS-100WBU.•Built in backup amplifier test feature allows you to physicallytest that the backup amplifier is operating properly.•Up to four amplifiers per 5820XL-EVS distributed betweenup to 32 audio circuits.•Six-wire connection to EVS system: Two-wires for the voicebus and four-wires for the SBUS connections.•Amplifier Bandwidth 400 Hz to 4000 Hz.•Can be mounted up to 6000 feet away from 5820XL-EVScontrol panel.•120 VAC or 240 VAC operation.•UL 864 and UL 2572•UL listed for Continuous or ANSI 520Hz speaker tones thatmeet NFPA 72 Low Frequency Signal Requirements forSleeping Areas. See the 5820XL-EVS installation manualLS10061-001SK-E for a list of compatible speakers. InstallationThe EVS-100W can be surface or flushmounted. CompatibilityThe EVS-100W is compatible with thefollowing voice evacuation components:•Version 14.0 or newer 5820XL-EVS VoiceIntegration Panel with Fire Alarm Control P/N 350961 Rev CCopyright © 2016 Honeywell International Inc. INTELLIGENT AMPLIFIER SpecificationsPhysicalFlush Mount Dimensions: 14.5”W x 24.75”H x 3.4”D(36.8 W x 62.9 H x 8.7 D cm)Overall Dimensions:16.1”W x 26½”H x 4 1/8”D(40.6 W x 66.7 H x 10.5 D cm)Color: RedEnvironmentalOperating Temperature: 32ºF – 120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensingElectricalPrimary AC: 120 VAC @ 60 Hz; 240 VAC @ 50 HzStandby Current:EVS-100W 25V 110 mAEVS-100W 70.7V 110 mAAlarm Current:EVS-100W 25V, 1.2 AEVS-100W 70.7V, 1.4 ATotal Power: 100 W @ 25 VRMS or 70.7 VRMS• Circuit 1-4: 50 W max. • Circuit 5-8: 50 W max.Main EVS Panel SBUS Standby & Alarm: 10 mABattery Charging Capacity: 7 – 35 AHBattery Size: 18 AH max allowed in cabinet. Use RBBaccessory cabinet for larger batteries up to 35 AH persystem.Voice Integration Wiring: Six conductorTwo voice bus Four SBUSListingsNFPA 13, NFPA 70, NFPA 72, UL 2572, UL 1711 & UL 864 &UL2572CSFM (pending); MEA (pending) Ordering InformationEVS-100W Intelligent 50/100 Watt AmplifierAccessoriesEVS-100WBU External Backup AmplifierRBBRemote Battery Box Accessory Cabinet. Use for backup batteries up to 35 AH. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specificationsare subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road,Northford, CT 06472 Phone: (203) 484-7161, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com. Agency Listings S2522 3034401 7300-1653:0212 7300-1653:0211 7135-1653:0196 9080301 Duct Smoke Detector Accessories Expand the versatility of the InnovairFlex™ line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA151 Piezo Annunciator MHR Mini-Horn, Red MHW Mini-Horn, White RA100Z/RA100ZA Remote Annunciator RTS151 Remote Test Station RTS151KEY Remote Test Station with Key RTS2 Multi-Signaling Accessory AOS Add-On Strobe RTS2-AOS Multi-Signaling Accessory Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. The MHR and MHW SpectrAlert® Advance mini-horns feature temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTS151 and RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFlex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2- AOS model. 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2013 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. HVDS20202 • 8/13 APA151 Piezo Annunciator Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49°C (32°F to 120°F) Relative Humidity 10 to 93% non-condensing Wire Gauge 12 to 18 AWG Dimensions 4.6˝ H × 2.9˝ W × .45˝ D MHR/MHW SpectrAlert® Advance Mini-Horns Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC 29 mA RMS max. at 16 to 33 Volts DC Temperature Range 0°C to 49°C (32°F to 120°F) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3 kHz Wire Gauge 12 to 18 AWG Dimensions 4.6˝ H × 2.9˝ W × 0.45˝ D RA100Z/RA100ZA Remote Annunciator Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 10 mA Dimensions 4.6 ˝ H × 2.8˝ W × 1.3˝ D Specifications, Duct Smoke Detector Accessories RTS151 Remote Test Station Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Test Switch 10 VA @ 32 VDC Reset Switch 10 VA @ 32 VDC Alarm Response Time 40 seconds max. Temperature Range –10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Dimensions 4.8˝ H x 2.90˝ W x 1.4˝ D RTS151KEY Remote Test Station with Key Power Requirements Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Alarm Response Time 40 seconds max. Temperature Range –10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Dimensions 4.6˝ H × 2.75˝ W × 1.8˝ D RTS2 and RTS2-AOS Multi-signaling Accessory Voltage 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range –10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8˝ W x 5.3˝ H x 1.6˝ D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. RTS151 UL S4011 RA100Z UL S2522 RTS151KEY UL S2522 MHW UL S4011 MHR UL S4011 APA151 UL S4011 RTS2-AOS UL S2522 AOS DescriptionThe SK-Pull-SA is a single action pull station requiring onlyone motion to activate the station. The SK-Pull-DA is a dualaction pull station requiring two motions to active the station.Both pull stations are designed to work with Silent KnightIntelliknight series fire alarm control panels (FACPs).Features• Installer can open station without causing an alarmcondition • Dual-color LED is visible through handle of station blinksgreen to indicate normal operation and remains steady redin an alarm condition •Key operated test and reset lock using lock plate actuator •Key matches compatible FACP locks •Meets the Americans with Disabilities Act AccessibilityGuidelines (ADAAG) controls and operating mechanismsguidelines (Section 4.1.3[13]) •Meets ADA requirement for 5 lbs maximum pull force toactive • Shell, door, and handle molded from durable LEXAN ® •Reliable analog communications for trouble-free operation • Braille text on station handle • Handle latches in down position and the word Activatedappears, clearly indicating the station has been pulled •Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually ActuatedSignaling System SK-Pull-SA and SK-Pull-DA The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use withSilent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SAprovide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizeseach manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Intelligent Pull Stations INTELLIKNIGHT ACCESSORY CompatibilityThe SK-Pull-SA and SK-Pull-DA are compatiblewith the following IntelliKnight FACP’s:5600570058085820XL SK-Pull-SA SK-Pull-DA INTELLIKNIGHT ACCESSORY Model SK-Pull-DA and SK-Pull-SAIntelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knightmodel SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station.SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADArequirements for a 5 lb. maximum pull force to activate the pull station. MADE IN AMERICA FORM# 350135 Rev B ©2012 Honeywell International Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact SilentKnight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com SpecificationsPhysicalHeight: 5.5” (14 cm)Width: 4” (10.2 cm)Depth: 5.4 oz. (3.7 cm)Housing Material: LEXAN polycarbonate resinBi-Colored LED:Blinking Green: NormalSteady Red: AlarmSwitch: Single pole, single throw (SPST) normally open (N/O)switch which closes upon activation of the pull station ElectricalOperating Voltage: 15–32 VDCAverage Operating Current (LED flashing): 300 µAWire Gauge: Up to 12 AWG (3.1 mm2)EnvironmentalOperating Temperature 32º – 120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensing AccessoriesBG-TR Optional trim ring.SB-I/O Surface backbox DescriptionThe SK-Monitor is an addressable monitor module for usewith Silent Knight IntelliKnight series fire alarm controlpanels (FACPs). The SK-Monitor is intended for use inintelligent, two-wire systems, where individual address ofeach module is selected using the built-in rotary switches.The SK-Monitor supports Class A supervised or Class Bsupervised wiring to the load device. Conventional 4-wiresmoke detectors can be monitored for alarm and troubleconditions.Features• Single contact monitor•Support for Class A and Class B wiring• Fully supervised•Panel controlled status LED that flashes green innormal state and is solid red in alarm• Attractive ivory cover plate• Rotary address switches for fast installation• SEMS screws for easy wiring• UL ListedInstallationThe SK-Monitor mounts directly into a 4” square electricalbox. The box must have a minimum depth of 2-1/8”. Asurface mount electrical box (System Sensor®PNSMB500) is available from Silent Knight.CompatibilityThe SK-Monitor is compatible with the followingIntelliKnight FACP’s:570058085820XL SK-Monitor The SK-Monitor module provides an interface to contact devices, such as security contacts, waterflow switches,or pull stations.For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Intelligent Monitor Module INTELLIKNIGHT ACCESSORY SpecificationsPhysicalHeight: 4.5” (11.4 cm)Width: 4” (10.2 cm)Depth: 1.25” (3 cm)Shipping Weight: 6.3 oz (196 g)ElectricalOperating Voltage: 15 – 32 VDCCurrent Draw (LED on): 5.0 mA maxOperating Current (LED flashing): 375 µA SK-Monitor INTELLIKNIGHT ACCESSORY Model SK-MonitorIntelligent Monitor Module MADE IN AMERICA FORM# 350131 Rev C ©2012 Honeywell International Inc. This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com Standby Current:400 µA max @ 24 VDC (one communication every 5 secwith 47K EOL)550 µA max @ 24 VDC (one communication every 5 secwith EOL <1K)5.5 mA (with LED latched on)LED Current: 5.5 mA (with LED latched on)End-of-LineResistance: 47K Initiating Device Circuit Wiring Resistance: 1,500 maxSLC Loop Resistance: 40 max. EnvironmentalOperating Temperature: 32ºF – 120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensing Ordering InformationSK-Monitor Monitoring Module AccessoriesSMB500 4” Square Surface Mount ElectricalBox 2-Wire Initiating Circuit Configuration, NFPA Style B 4-Wire Initiating Circuit Configuration, NFPA Style D DescriptionThe SK-Control is an addressable notification module for usewith Silent Knight IntelliKnight series fire alarm control panels(FACPs). The SK-Control provides supervised monitoring ofwiring to load devices that require an external power supplyto operate, such as bells, horns, and strobes. It is capable ofClass B (Styles Y) and Class A (Style Z) supervision.Upon command from the FACP,the SK-Control willdisconnect the supervision and connect the external powersupply across the load device. The disconnection of thesupervision provides a positive indication to the panel that thecontrol relay actually turned on. The external power supply isalways relay isolated from the SLC loop, so that a troublecondition on the power supply will never interfere with therest of the system.Features•Flexible solution for adding notification circuits whereneeded• Support for Class B (style Y) or Class A (style Z) wiring• Panel controlled status LED that flashes green in normalstate and is solid red in alarm•Polling LED visible through the cover plate•Attractive ivory cover plate• Rotary address switches for fast installation• SEMS screws for easy wiring• UL Listed SK-Control The SK-Control gives you the flexibility to add notification circuits wherever they are needed on an IntelliKnightFACP signaling line circuit (SLC) loop. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Intelligent Notification Module INTELLIKNIGHT ACCESSORY InstallationThe SK-Control mounts directly into a 4” squareelectrical box. The box must have a minimumdepth of 2-1/8”. A surface mount electrical box(System Sensor®PN SMB500) is availablefrom Silent Knight.CompatibilityThe SK-Control is compatible with the followingIntelliKnight FACP’s:•5700•5808•5820XL SK-Control INTELLIKNIGHT ACCESSORY Model SK-ControlIntelligent Notification Module MADE IN AMERICA FORM# 350125 Rev B ©2010 Honeywell International Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact SilentKnight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. www.silentknight.com SpecificationsPhysicalHeight: 4.5” (11.4 cm)Width: 4” (10.2 cm)Depth: 1.3” (3.2 cm)Shipping Weight: 6.3 oz (196 g)EnvironmentalOperating Temperature: 32ºF – 120ºF (0ºC – 49ºC)Humidity: 10% – 93% non-condensingElectricalOperating Voltage: 15 – 32 VDCCurrent Draw: 6.5 mA max (LED on)Operating Current: 375 µA average (LED flashing) Drain on External Power Supply: 1.7 mA max (using internalEOLrelay)End-of-Line Resistance: 47K Standby Current400µA max @ 24 VDC (one communication every 5 sec with 47K EOL)550µA max @ 24 VDC (one communication every 5 sec with EOL <1K)LED Current: 5.5 mA (with LED latched on)SLC Loop Resistance: 40 max.AccessoriesSMB500 DescriptionThe SK-Relay is an addressable relay module for use withSilent Knight IntelliKnight series fire alarm control panels(FACPs). The SK-Relay allows a Silent Knight FACP to switch discretecontactsby code command. The relay contains two isolatedsets of Form C contacts, which operate as a DPDT switch. Nosupervision is provided for the notification appliance circuit.The SK-Relay contacts can be used for virtually any normallyopen or normally closed application. Each SK-Relay isprogrammed with a unique signaling line circuit (SLC) loopaddress. When an event occurs that controls the SK-Relay,therelay is triggered by the FACP.Features• Two sets of Form C contacts• Rotary address switches for fast installation• Contacts are rated for a variety of amps (see Specifications)•Panel controlled status LED that flashes green in normalstate and is solid red in alarm• Relay programming is completely flexible–can be mapped tozone conditions• Polling LED visible through the cover plate• Attractive ivory cover plate• SEMS screws for easy wiring• UL Listed SK-Relay The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of eachmodule is selected using the built in rotary switches.For more information about the Intelliknight system, or to locate you nearest source, please call 800-328-0103. Intelligent Relay Module INTELLIKNIGHT ACCESSORY SK-RelayInstallationThe SK-Relay mounts directly into a 4” squareelectrical box. The box must have a minimumdepth of 2-1/8”. A surface mount electrical box(System Sensor®PN SMB500) is availablefrom Silent Knight CompatibilityThe SK-Relay is compatible with the followingIntelliKnight FACP’s:5820XL580857005600 (Rev 2.0 or higher) INTELLIKNIGHT ACCESSORY Model SK-RelayIntelligent Relay Module MADE IN AMERICA FORM# 350127 Rev C ©2011 Honeywell International Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact SilentKnight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com SpecificationsPhysicalHeight: 4.65” Width: 4.25”Depth: 1.1” Shipping Weight: 6.3 oz (196 g)ElectricalOperating Voltage: 15 – 32 VDCCurrent Draw: 6.5 mA max (LED on)Operating Current:230 µA (LED flashing) direct poll255 µA (LED flashing) group poll End-of-Line Resistance: not usedStandby Current: 300 µA max @ 24 VDC (one communication every 5 sec with LED enabled)LED Current: 5.5 mA (with LED latched on)SLC Loop Resistance: 40 max.Relay Contact Ratings3.0A @ 30 VDC resistive0.9A @ 110 VDC resistive0.9A @ 125 VAC resistive0.5A @ 125 VAC inductive (PF = .35)0.7A @ 75 VAC inductive (PF = .35) DescriptionThe Model SK-Duct Air Duct Smoke Detector utilizesphotoelectric technology for the detection of smoke. Itprovides early detection of smoke and products ofcombustion present in air moving through HVAC ducts inCommercial and Industrial applications.The SK-Duct is in a heavy duty gray steel back box with aclear cover. It features a pivoting housing that fits bothsquare and rectangular footprints capable of mounting to a round or rectangular duct. It installs quickly and easily.The unit senses smoke in the most challenging conditions,operating in airflow speeds of 100 to 4000 feet per minute,temperatures of -4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing).Features• Versatile mounting options: square or rectangularconfiguration• New Cover tamper signal•LED alarm indication and communication on sensorhead•Detects and limits the spread of smoke•Rugged steel back box with clear plastic cover•Easy to clean•Large terminal connection screws• Transparent cover for convenient visual inspection•Patented sampling tube installs from front or back of thedetector with no tools required• Available space within housing to accommodatemounting of relay module• UL listed SK-DUCTIntelligent Air DuctSmoke Detector The SK-Duct Intelligent air duct smoke detector is used with SK-PhotoR (included) for detecting smoke andproducts of combustion present in air moving through an HVAC air handling system. When smoke is detected inaduct, the unit communicates the condition to the IntelliKnight control panel. The panel, in turn, depending onprogramming and wiring, turns off fans, blowers, and other devices. The duct housing allows for mounting ofSK-Relay addressable relay module. Now there's even more power and flexibility available to the IntelliKnightfamily of products! Detect smoke in air handling systems and air handling equipment with Silent Knight's addressable duct smoke detector INTELLIKNIGHT ACCESSORY SK-DUCTSpecificationsPhysical(Rectangular): 14.38 in (37 cm) Length; 5in (12.7 cm) Width; 2.5 in (6.6 cm) Depth(Square): 7.75 in (19.7cm) Length; 9 in (22.9cm) Width; 2.5 in (6.35cm) DepthWeight: 1.6lb (0.73kg)EnvironmentalOperating Temperature: -4ºF – 158ºF (-20ºC – 70ºC)Humidity: 0% – 95% (non-condensing)Air Velocity100 to 4000 ft/min (0.5 – 20.3 m/sec.)Electrical (using SK-Photo or SK-PhotoR)Operating Voltage: 15–32 VDCStandby Current: 300 µA @ 24 VDC max.Alarm Current: 6.5 mA @ 24 VDC max (with LED on) INTELLIKNIGHT ACCESSORYModel SK-DUCTAir Duct Smoke Detector Engineering Specifications The air duct smoke detector shall be a SK-Duct photoelectric duct smoke detector. The detector housing shallbe UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smokedetector fits both square and rectangular footprints. The detector shall operate at air velocities of 100 ft/min to4000 ft/min (0.5 m/sec to 20.32 m/sec).The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed orimproperly installed. It shall be capable of local testing via magnetic switch or remote testing using theRTS151KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for12–18AWG wiring.The unit housing shall be capable of mounting a relay module. MADE IN AMERICA FORM# 350122 Rev D ©2010 Honeywell International Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specificationsare subject to change without notice. For more information, contact SilentKnight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. www.silentknight.com Ordering Information SK-Duct Intelligent non-relay duct smoke detectorSK-Photo Addressable Photo DetectorSK-PhotoR Addressable Photo Detector with remote testcapability (included with SK-Duct)SK-Relay Addressable Relay Module, must be added ifrelay function is required, (fits in housing)Accessories†DST1 Metal Sampling Tube Duct Width up to 1’DST1.5 Metal Sampling Tube Duct Widths 1’ - 2’DST3 Metal Sampling Tube Duct Widths 2’ – 4’DST5 Metal Sampling Tube Duct Widths 4’–8’DST10 Metal Sampling Tube Duct Widths 8’ – 12’DH400OE-1 Weatherproof EnclosureETX Metal Exhaust Tube Duct width 1’RA100Z Remote LED AnnunciatorDCOIL Duct accessory coil, required if using with SK-Photo and not SK-PhotoR (included) withSK-DuctRTS151 Magnetic Remote Test stationRTS151KEY Key-Activated Remote Test station M02-04-00 Test MagnetP48-21-00 Replacement End Cap for Metal Sampling TubeAPA151 Remote annunciator with piezo alarm Important Notes:•The use of either RTS151 or RTS151KEY requires theinstallation of an accessory coil, DCOIL, sold separately.Please refer to the SK-Duct installation instructions formore information•The RTS151/RTS151KEY test coil circuit requires anexternal 24VDC power supply which must be UL listed. Accessory Current Loads at 24 VDCDeviceStandbyAlarmRA100Z0mA12mAMax.RTS151 0mA 12mA Max.RTS151KEY 12mA 12mA Max. DescriptionSK-Heat, SK-Heat-HT and SK-Heat-ROR are intelligent sensorsthat utilize a state-of-the artthermistor sensing circuit for fastresponse. Sensitivity iscontinuously monitored andreported to the FACP.Point IDcapability allows each detector’saddress to be set with rotaryaddress switches, providing exactdetector locations for selectivemaintenance when chambercontamination reachesunacceptable levels. SK-Heat is a fixed temperaturesensor that uses a thermistorsensing circuit to produce 135ºF(57ºC) fixed temperature alarm.SK-Heat-HT is a variable hightemperature detector that provideshigh temperature detection at 135°F - 190ºF.(57°C - 88°C)SK-Heat-ROR is a rate-of-risetemperature sensor with 135ºF(57ºC) fixed temperature alarm.Features•Reliable analog communicationsfor trouble-free operation• Age resistant polymer housing• Innovative thermistor sensingcircuit • Superior EMI resistance forreliability• Variety of mounting options tomeet any application• Dual LED indicators for 360º visibility• Detector transmits signal toindicate maintenance is required•Plug-in mounting provides easeof installation•Optional remote LED annunciator(System Sensor®PN RA100Z)•Tamper-proof feature available onmounting bases•Rotary address switches for fastinstallation• UL ListedSpecificationsPhysicalHeight: 2.0” (51 mm)Diameter: 6.1” (155 mm)installed inB210LPbase Shipping Weight: 4.8 oz (137 g)ElectricalOperating Voltage: 15 to 32 VoltsDC PeakStandby Current: 300µA @ 24VDCLED Current: 6.5 mA@ 24 VDC EnvironmentalOperating TemperatureSK-Heat & SK-Heat-ROR: -4º – 100ºF (-20ºC– 38ºC)SK-Heat-HT: -4º – 150ºF (-20ºC – 66ºC)Humidity: 10% – 93%noncondensingThermal RatingsSK-Heat: Fixed temperature alarm135ºF (57ºC) SK-Heat-HT: High temperature heatsensor 135°F - 190ºF (57°C - 88ºC)SK-Heat-ROR: Rate-of-risedetection 15ºF/min (8.3ºC/min)CompatibilityThe SK-Heat-HT and SK-Heat-ROR are compatible with thefollowing IntelliKnight FACP’s:5820XL58055700The SK-Heat is compatible with thefollowing IntelliKnight FACP’s:5820XL580857005600 (Rev 2.0 or higher)The SK-Heat, SK-Heat-HT and SK-Heat-ROR are compatible with thefollowing detector bases:B210LP 6” base (included)B501 2 wire baseB224BI Isolator baseB224RB Relay baseB200SR Sounder base SK-Heat, SK-Heat-HTandSK-Heat-ROR The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, thatprovide features that surpass conventional detectors. These thermal detectors are for use with Silent KnightIntelliKnight series Fire Alarm Control Panels (FACPs).IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnightpanel recognizes each detector by its specific address, so precious seconds are not wasted in determininglocation of an alarm. Addressable Thermal Heat and Rate-of-Rise Detectors INTELLIKNIGHT ACCESSORY SK-Heat (base included) INTELLIKNIGHT ACCESSORY Model SK-Heat, SK-Heat-HT,SK-Heat ROR Addressable Thermaland Rate-of-Rise Thermal Detectors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent KnightModel SK-Heat, SK-Heat-HT or SK-Heat-ROR. The base included shall be B210LP.The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated, theflashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel resetswitch.The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. Thelocking feature shall be field removable when not required.Voltage and RF/transient suppression techniquesshall be employed to minimize false alarm potential. MADE IN AMERICA FORM# 350120 Rev. D©2011 Honeywell International Inc. This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight12 Clintonville Road Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118.www.silentknight.com AccessoriesRA100Z - Remote LED Annunciator.RMK400 - Recessed Mounting Kit. Provides low profile for use withB501.XR2B - Detector Removal Tool. A removal and re- placement toolfor SK plug-in detectors. Includes the T55-127-000.M02-04-01 - Replacement Test Magnet. M02-09-00 - Test Magnet with Telescoping Handle.XP-4 - Extension Pole for XR2B. Extends from 5 – 15 ft.T55-127-000 - Detector Removal Head.BCK-200B - Black Detector Kit. For SK-series detectors.*Unless otherwise noted, specifications apply to all SK thermaldetectors. DescriptionSK-Photo and SK-Photo-T are plug-intype smoke sensors that combine aphotoelectric sensing chamber withaddressable analog communications.Point ID capability allows eachdetector’s address to be set with rotaryaddress switches, providing exactdetector locations for selectivemaintenance when chambercontamination reaches unacceptablelevels.SK-Photo and SK-Photo-T have aunique optical sensing chamber that isengineered to sense smoke producedby a wide range of combustionsources. In the SK-Photo-T, dualelectronic thermistors add 135ºF (57ºC)thermal technology to maximizedetection.The SK-PhotoR is a remote testcapable detector for use with theDNR/DNRW duct smoke detector. (notincluded) Features•Sleek, low-profile design•Base included•Reliable analog communications fortrouble-free operation•Age resistant polymer housing•Dual electronic thermistor design onthe SK-Photo-T•Superior EMI resistance for reliability•Simple field cleaning for codecompliance•Variety of mounting options to meetany application•Dual LED indicators for 360º visibility•Detector transmits signal to indicatemaintenance is required •Optional remote LED annunciator(System Sensor® PN RA100Z)•Plug-in mounting provides ease ofinstallation•Tamper-proof feature available onmounting bases•Listed for use in duct applications•Rotary address switches for fastinstallation•UL Listed•FM ApprovedSpecificationsPhysicalHeight: 2.0” (5.0 cm)Diameter: 4.1” (10.4 cm) installed inB501 baseElectricalOperating Voltage: 15–32 VDCStandby Current:300 µA @ 24 VDC MaximumAlarm Current: 6.5 mA @ 24 VDC max(with LED on)EnvironmentalOperating TemperatureSK-Photo: 32º – 120ºF (0ºC – 49ºC)SK-Photo-T: 32º – 100ºF (0ºC – 38ºC)Humidity: 10% – 93% non-condensingOther RatingsSK-Photo-T Thermal: Fixedtemperature set point 135ºF (57ºC)Velocity: 0 – 4000 fpm (0 – 20 m/sec) InstallationThe SK-Photo and SK-Photo-T pluginto a compatible IntelliKnight-seriesdetector base. The SK-PhotoR is aremote test capable detector headincluded within the DNR (W) ductsmoke detector.CompatibilitySK-Photo, and SK-Photo-T arecompatible with the following detectorbases:B210LP 6” base (included)B501 2 wire baseB224RB Relay baseB224BI Isolator baseB200SRSounder baseThe SK-Photo, SK-Photo-T, and SK-PhotoR are compatible with thefollowing IntelliKnight FACPs:5820XL5820XL-EVS580857005600 (Rev 2.0 or higher) SK-Photo, SK-Photo-Tand SK-PhotoR The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermaland SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, withintegral communication, provide features that surpass conventional detectors and are for use with Silent KnightIntelliKnight Fire Alarm Control Panels (FACPs).For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Intelligent Photoelectric Smoke Sensors SK-Photo (Base included) INTELLIKNIGHT ACCESSORY INTELLIKNIGHT ACCESSORYModel SK-Photo, SK-Photo-T and SK-PhotoRIntelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensorsSilent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shallbe UL listed and compatible with Silent Knight’s IntelliKnight fire control panels.The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lockbase part number B210LP (included).The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included).The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, theflashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch.The calibration of the detector shall be capable of being selected and measured by the control panel without theneed for external test apparatus.The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. Thelocking feature shall be field selectable as required.The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effectsof products of combustion in the chamber to ensure testing of detector circuits. MADE IN AMERICA FORM# 350118 Rev E© 2013 Honeywell International Inc. This document is not intended to be used for installation purposes. We try tokeep our product information up-to-date and accurate. We cannot cover allspecific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact Silent Knight12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444.www.silentknight.com Agency Listings Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from –40°F to 151°F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from −40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with ¾-inch top and bottom conduit entries and ¾-inch knock-outs at the back. A screw-in NPT plug with an O-ring gasket for a watertight seal is included with each back box. Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. MEA452-05-E3023572 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S3593 (outdoor and alert strobes) AVDS01201 SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between −40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 2.5˝ D (142 mm L × 119 mm W × 64 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB)5.7˝ L × 5.1˝ W × 2.0˝ D (145 mm L × 130 mm W × 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output DataCandela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS01201 • 3/12 SpectrAlert Advance Diagrams Model Description Wall Horn Strobes P2RK*†2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*†2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*†2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*†2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RK†4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*†Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*†Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*†Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*†Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRK†Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2RK-P. † Add “-R” to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 4.7˝ 5.6˝ 6.8˝ Dia. 2.5˝ 2.5˝ Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box Wall-Mount Horn Strobe with Plastic Weatherproof Back Box Agency Listings 7320-1653:0505S4048FM approved except for ALERT models 3057493 Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Wall Applications System Sensor L-Series selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features • Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation • No extension ring required • Field selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, 185 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) • Seakers offer high fidelity and high volume sound output • Compatible with System Sensor synchronization protocol • Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products • Tamper-resistant construction • Updated modern aesthetics The System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for wall speaker strobes. The low total harmonic distortion of the speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. System Sensor L-Series makes installation easy • Attach a universal mounting plate to a 4 × 4 × 21⁄8 inch back box. Flush-mount applications do not require an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General L-Series speaker and speaker strobes shall mount to a 4 × 4 × 21⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Wall- mount speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, 185. Speaker The speaker shall be a System Sensor L-Series model _______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model __________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Wall-Mount Length Width Depth SPL Speaker 6.5 in, 165 mm 5 in, 127 mm .97 in,23 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 3.2 in, 82 mm SPSL Speaker/Strobe (including lens and speaker) 6.5 in, 165 mm 5.0 in, 127 mm 2.3 in, 58 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 4.5 in, 116 mm Electrical/Operating Specifications Nominal Voltage (speakers)25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC or regulated 24 DC/FWR1,2 Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33V (24 V nominal) Frequency Range 400 to 4000 Hz Power ¼, ½, 1, 2 watts 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 and 30 cd UL Current Draw Data UL Max Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC DC FWR 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Sound Output Speaker Strobe ¼ W ½ W 1 W 2 W UL Reverberant (dBA @10 ft)77 80 83 86 UL Anechoic (dBA @10 ft)77 80 83 86 Sound Output Speaker ¼ W ½ W 1 W 2 W UL Reverberant (dBA @10 ft)79 82 85 88 UL Anechoic (dBA @10 ft)79 82 85 88 L-Series Dimensions Wall-Mount Speaker Wall-Mount Speaker Strobe 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86701 • 03/17 L-Series Ordering Information Wall Mount White Red Description SPWL SPRL Speaker only SPSWL SPSRL Speaker Strobe SPSWL-P SPSRL-P Plain Speaker Strobe SPSWL-ALERT —Speaker Strobe, Amber Lens SPSWL-CLR-ALERT —Speaker Strobe Clear Lens —SPSRL-SP Speaker Strobe, Fuego Accessories White Red Description RFPW RFP 7 in × 9.5 in Retrofit Plate SBBSPWL SBBSPRL Surface Mount Back Box for Speakers and Speaker Strobes TR-2W TR-2 Wall Mount Trim Ring Notes: All -P models have a plain housing (no “FIRE” marking on the cover) Surface Mounting Wall-Mount Speaker Strobe with SBBSPL Surface Mount Back Box Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications System Sensor L-Series selectable-output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features • Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation • No extension ring required • Field selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) • Speakers offer high fidelity and high volume sound output • 520 Hz capable with compatible FACP • Compatible with System Sensor synchronization protocol • Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products • Tamper-resistant construction • Updated modern aesthetics System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. L-Series makes installation easy • Attach a universal mounting plate to a 4 × 4 × 21⁄8 inch back box . Flush-mount applications do not require an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw.Agency Listings 7320-1653:0505S4048FM approved except for ALERT models 3057493 L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General L-Series speaker and speaker strobes shall mount to a 4 × 4 × 21⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, 177. Speaker The speaker shall be a System Sensor L-Series model _______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model __________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount Back Box 6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Back Box 6.9 in, 176 mm 5.37 in, 136 mm Electrical/Operating Specifications Nominal Voltage (speakers)25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC or regulated 24 VDC/FWR 1,2 Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz3 Power ¼, ½, 1, 2 watts 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 and 30 cd. 3. 520Hz capable with compatible FACP. UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Ceiling-Mount Speaker Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Ceiling-Mount Speaker Strobe Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 L-Series Dimensions Ceiling Speaker Ceiling Speaker Strobe 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86601 • 03/17 L-Series Ordering Information Ceiling Mount White Red Description SPCWL SPCRL Speaker only SPSCWL SPSCRL Speaker Strobe SPSCWL-P —Plain, Speaker Strobe SPSCWL-SP —Fuego, Speaker Strobe SPSCWL-CLR-ALERT —Alert, Speaker Strobe, Clear Lens Accessories White Red Description SBBCWL SBBCRL Universal Ceiling Surface Mount Back Box TRC-2W TRC-2 Universal Ceiling Trim Ring Surface Mounting Ceiling Speaker with Surface Mount Back Box Ceiling Speaker Strobe with Surface Mount Back Box Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383, 3057072 Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 × 4 × 17⁄8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411 ⁄16 × 411 ⁄16 × 21 ⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1,2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 1.91˝ D (143 mm L × 119 mm W × 49 mm D) Compact Wall-Mount Dimensions (including lens)5.26” L x 3.46” W x 1.91” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.25˝ D (143 mm L × 119 mm W × 32 mm D) Compact Horn Dimensions 5.25” L x 3.45” W x 1.25” D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9*Coded High 85 90 90 10*3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Candela Range (15–115 cd) DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Current Draw Data Horn Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86503 • 03/17 L-Series Dimensions Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT L-Series Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover) All -SP models have “FUEGO” marking on cover All -ALERT models have “ALERT” marking on cover Compact Strobe / Horn Strobe Strobe / Horn Strobe Compact Horn Horn Model Description Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White DF-51410 • 03/17/05 — Page 1 of 2 GENERAL FM Series electromagnetic door holders are designed for virtually any remote door release application. They are pri- marily used to hold fire and smoke barrier doors open until released by a remote smoke detector or other switching device. The complete assembly consists of: an armature contact plate with adjustable pivot mounting for installation in the door, and a heavy-duty electromagnet, in a durable plastic enclosure, mounted on the wall or floor behind the door. A separate closing device is required. FEATURES • All models support 12 VDC, 24 VAC/VDC, or 120 VAC. • Improperly applied voltage does not damage the unit. • Spacing kit for odd angles. • 25 to 40 pounds (11.3 kg) holding power. • Magnet protected against transients and surges up to 600 volts (AC models). • Fail-safe operation; power failure releases door to close. • Positive release button initiates closing motion. • Two-year warranty. • Floor- and wall-mount models. INSTALLATION • Used in hospitals, schools, offices, nursing homes, and public buildings. • Install where required by code, where doors may be used to confine smoke or fire, or wherever remote control or automatic closing doors are required. • Ensure that door hardware and trim projections are com- patible with total projection of door release. • Anchor the electromagnet firmly, as the wall portion will function as a doorstop. • Locate magnet approximately 6" (15.24 cm) in from the lock stile at the door. Wall magnets should be mounted approximately two to four feet (0.61 to 1.22 meters) above the floor for optimum performance. • Door-mounted contact plate includes hardware for thrubolting or concealed mounting. • Spotting template included with unit assures correct align- ment. • 14 AWG (2.0 mm²) maximum wire size. ORDERING INFORMATION FM980 Surface floor-mount model for single door; 12 VDC, 24 VAC/VDC, 120 VAC. FM996 Surface wall-mount model; 12 VDC, 24 VAC/VDC, 120 VAC. FM998 Flush wall-mount model; 12 VDC, 24 VAC/VDC, 120 VAC. FM900 Extension kit. FM900-Z Extension kit, 90°. FM900-50 Spacer, 1/2" (1.27 cm). FM900-75 Spacer, 3/4" (1.905 cm). FM-900-100 Spacer, 1" (2.54 cm). 5286ph1.jpg FM996 Fire•Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product informa- tion up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. FM Series Electromagnetic Door Holders DF-51410 • I-100March 17, 2005 Section: Miscellaneouswww.firelite.com R11746 MEA 447-00-E 3550-0075:173 California State Fire Marshal BSA 750-76-SA (FM980, FM998) Page 2 of 2 — DF-51410 • 03/17/05 • Total projection: 4-1/8" (105 mm). • Mounting requirements: 1-1/2" (38 mm) deep adapter housing. • UL-Listed door holder. • Concealed wiring. • Total floor space required: 6-5/8" (168 mm). • Mounting requirements: Conduit connects directly to floor plate. MODEL 996 Wall-Mount Surface Wiring • UL-Listed door holder. • Voltage/current: 120 VAC, 60 Hz, 0.020 amp. 24 VAC/VDC, 60 Hz, 0.020 amp. 12 VDC, 0.040 amp. • Shipping weight: 4 lbs. (1.8 kg). • Voltage/current: 120 VAC, 60 Hz, 0.020 amp. 24 VAC/VDC, 60 Hz, 0.020 amp. 12 VDC, 0.040 amp. • Shipping weight: 3 lbs. (1.4 kg). • Total projection: 3-5/8" (92 mm). • Mounting requirements: 2" x 4" x 1-3/4" (51 x 102 x 45 mm) outlet box. • Wall must be properly reinforced and outlet box adequately fastened. MODEL 998 Wall-Mount Standard Doors Concealed Wiring • UL-Listed door holder. • Voltage/current: 120 VAC, 60 Hz, 0.020 amp. 24 VAC/VDC, 60 Hz, 0.020 amp. 12 VDC, 0.040 amp. • Shipping weight: 2-1/2 lbs. (1.1 kg). MODEL 980 Floor-Mount Single Door 5286m980.tif 5286m996.tif 5286m998.tif PS S E R I E S TERMINALS: (mm) DIMENSIONS: inch (mm)PERFORMANCE SPECIFICATIONS Nominal Voltage 12 volts (6 cells) Nominal Capacity 20-hr. (350mA to 10.50 volts) 10-hr. (650mA to 10.50 volts) 5-hr. (1.2A to 10.20 volts) 1-hr. (4.5A to 9.00 volts) 7.00 AH 6.50 AH 6.00 AH 4.50 AH Approximate Weight 4.80 lbs. (2.18 kg) Internal Resistance (approx.) 23.0 milliohms Max Short-Duration Discharge Current (10 Sec.)70.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C) 1 Month 3 Month 6 Month 97% 91% 83% Operating Temperature Range Charge Discharge 5°F (-15°C) to 122°F (50°C) -4°F (-20°C) to 140°F (60°C) Case ABS Plastic Power Sonic Chargers PSC-12800A-C PSC-121000-PC www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com General Purpose Fire & SecurityEmergency Lighting MO DE L PS -1270 F1 12 Volt 7.0 Amp. Hr. Warning: Risk of fire, explosion, or burns.Do not disassemble, heat above 60 C, or incinerate. Rechargeable Sealed Lead-Acid BatteryDC power, constant voltage chargeCycle use: 14.4 - 15.0V(20 C)Standby use: 13.5 - 13.8V(20 C)Initial current: 2.1A MAX 8 0 1 3 3 4 0 0 1 0 0 0 Sealed R echargeable Battery 120070260211 L HT H W Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. L: 5.95 (151) W: 2.56 (65) H: 3.70 (94) HT: 3.86 (98) L: 5.95 (151) W: 2.56 (65) H: 3.70 (94) HT: 3.86 (98) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. FEATURES •Absorbent Glass Mat (AGM) technology for superior performance •Valve regulated, maintenance free spill proof construction •Power/volume ratio yielding excellent energy density •Rugged vibration and impact resistant ABS case and cover •Gas recombination technology •5 year design life APPROVALS •Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certifi ed •U.L. recognized •ISO9001:2015 – Quality management systems Medical Re v 1 : 1 1 / 1 8 PS-1270 12V 7.0 AH @ 20-hr.12V 6.5 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery PS – General Purpose Series OR Torque – Not Applicable 4. 7 5 1. 5 6.35 3.2 2.5 0. 8 F1: Quick disconnect tabs, 0.187" x 0.032" – Mate with AMP. INC. FASTON “187” series Torque – Not Applicable 6. 3 5 1. 5 7.95 3.4 2.5 0. 8 F2: Quick disconnect tabs, 0.250" x 0.032" – Mate with AMP. INC FASTON “250” series PS S E R I E S www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Cap a c i t y R e t e n t i o n R a t i o ( % ) Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC (104oF) 30oC (86oF)20oC (68oF) 5oC (41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage 2.25 - 2.30 V/Cell Ret e n t i o n C a p a c i t y ( % ) Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Cap a c i t y R e t e n t i o n R a t i o ( % ) Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC (104oF) 30oC (86oF)20oC (68oF) 5oC (41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage 2.25 - 2.30 V/Cell Ret e n t i o n C a p a c i t y ( % ) Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE CHARGING Cycle Applications: Apply constant voltage charge at 2.35v/c – 2.45v/c (14.1 – 14.7v for 12v Monobloc) at 20°C. Initial charging current should be set at less than 0.25C Amps. Switch to fl oat charge to avoid overcharging. “Float” or “Stand-By” Service: Apply constant voltage charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging Voltage for both Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifi cations. CHARGERS Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities. Please refer to our website for more information on our switch mode and transformer type chargers. Please contact our technical department for advice if you have diffi culty in locating a suitable charger. FURTHER INFORMATION Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certifi cation, etc. APPLICATIONS •General purpose •Emergency lighting •Medical •Fire and security PS-1270 12V 7.0 AH @ 20-hr.12V 6.5 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery PS – General Purpose Series Re v 1 : 1 1 / 1 8 PS S E R I E S TERMINALS: (mm) DIMENSIONS: inch (mm)PERFORMANCE SPECIFICATIONS Nominal Voltage 12 volts (6 cells) Nominal Capacity 20-hr. (600mA to 10.50 volts) 10-hr. (1.10A to 10.50 volts) 5-hr. (2.10A to 10.20 volts) 1-hr. (7.25A to 9.00 volts) 12.00 AH 11.00 AH 10.50 AH 7.25 AH Approximate Weight 7.92 lbs. (3.59 kg) Internal Resistance (approx.) 20.0 milliohms Max Short-Duration Discharge Current (10 Sec.)120.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C) 1 Month 3 Month 6 Month 97% 91% 83% Operating Temperature Range Charge Discharge 5°F (-15°C) to 122°F (50°C) -4°F (-20°C) to 140°F (60°C) Case ABS Plastic Power Sonic Chargers PSC-122000A-C PSC-122000-PC www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com General Purpose Fire & SecurityEmergency Lighting L HT W H Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. F2: L: 5.94 (151) W: 3.86 (98) H: 3.66 (93) HT: 3.86 (98) NB: L: 5.94 (151) W: 3.86 (98) H: 3.66 (93) HT: 4.09 (104) FEATURES •Absorbent Glass Mat (AGM) technology for superior performance •Valve regulated, maintenance free spill proof construction •Power/volume ratio yielding excellent energy density •Rugged vibration and impact resistant ABS case and cover •Gas recombination technology •5 year design life APPROVALS •Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certifi ed •U.L. recognized •ISO9001:2015 – Quality management systems Medical F2: L: 5.94 (151) W: 3.86 (98) H: 3.66 (93) HT: 3.86 (98) NB: L: 5.94 (151) W: 3.86 (98) H: 3.66 (93) HT: 4.09 (104) Re v 1 : 1 1 / 1 8 PS-12120 12V 12.0 AH @ 20-hr.12V 11.0 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery PS – General Purpose Series Torque – Not Applicable 6. 3 5 1. 5 7.95 3.4 2.5 0. 8 F2: Quick disconnect tabs, 0.250" x 0.032" – Mate with AMP. INC FASTON “250” series NB: Tin plated brass post with ‘Nut & Bolt’ fasteners Torque: 2.0~3.0 Nxm 12mm 5m m 5. 3 m m 11 m m 2mm Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. PS S E R I E S www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Cap a c i t y R e t e n t i o n R a t i o ( % ) Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC (104oF) 30oC (86oF)20oC (68oF) 5oC (41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage 2.25 - 2.30 V/Cell Ret e n t i o n C a p a c i t y ( % ) Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Cap a c i t y R e t e n t i o n R a t i o ( % ) Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC (104oF) 30oC (86oF)20oC (68oF) 5oC (41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage 2.25 - 2.30 V/Cell Ret e n t i o n C a p a c i t y ( % ) Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE CHARGING Cycle Applications: Apply constant voltage charge at 2.35v/c – 2.45v/c (14.1 – 14.7v for 12v Monobloc) at 20°C. Initial charging current should be set at less than 0.25C Amps. Switch to fl oat charge to avoid overcharging. “Float” or “Stand-By” Service: Apply constant voltage charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging Voltage for both Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifi cations. CHARGERS Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities. Please refer to our website for more information on our switch mode and transformer type chargers. Please contact our technical department for advice if you have diffi culty in locating a suitable charger. FURTHER INFORMATION Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certifi cation, etc. APPLICATIONS •General purpose •Emergency lighting •Medical •Fire and security PS-12120 12V 12.0 AH @ 20-hr.12V 11.0 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery PS – General Purpose Series Re v 1 : 1 1 / 1 8 Equipment Panel/Dedicated Circuit Surge Protective Device General Product Specifications DTK-HW Series DTK-120HW DTK-120/240HW Product Features • Diagnostic LED indicates ground presence, system power and SPD function • Weatherproof enclosure • Small footprint enables installation in a variety of locations • Available for popular 120V, and 120/240V systems • Complies with ANSI/IEEE C62.41 and C62.45 Category B standards • Ten Year Limited Warranty One DITEK Center 1720 Starkey Road Largo, FL 33771 1-800-753-2345 Technical Support: 1-888-472-6100 www.ditekcorp.com Document: SPS-100057-001 Rev 9 2/12 ©2011 DITEK Corp. Specification Subject to Change Specifications Agency Approvals: UL 1449, 3rd Edition, cUL IEEE Location Category: Category B Protector Type: SPD Type 2 Protection Modes: L-G, L-N, N-G Response Time: <1ns Temperature Range:-40°F – 185°F (-40°C – 85°C) Maximum Humidity: 95% non-condensing Operating Frequency: 0Hz – 400Hz Dimensions: 2.93” x 2.83” x 1.68” (74.4mm x 71.9mm x 42.7mm) Connection: ¾” diameter threaded fitting Weight: .5lb. (227g) Housing: ABS DITEK’s HW series of surge protectors are designed and manufactured to meet the exacting standards of the life safety industry. These compact parallel mount surge protectors are widely used to protect fire alarm panels and other dedicated branch circuit loads. 3,000A10,000A700V L-N, L-G; 600V N-G130V19,500ASingle Φ (2W + G), 120VAC120HW 3,000A10,000A 700V L-N, L-G; 600V N-G; 1200V L-L 130/260V 13,000A/ Phase 6,500A/ Mode Split Φ (3W + G), 120/240VAC120/240HW MCOV UL1449, 3rd Ed. InRating UL 1449, 3rd Ed. V.P.R. Short Circuit Current Rating Peak Surge Current Service Wiring Model Selection: DTK- For more Information please call 1-800-Belden1 General Description: Fire Alarm Cable, Plenum-FPLP, 2-14 AWG solid bare copper conductors with Flamarrest® insulation, Flamarrest®jacket with ripcord Usage (Overall) Suitable Applications:Fire Protection, Alarm, Signal, Monitor/Detection, Audio Circuits, Control Circuits, Initiating Circuits, Notification Circuits Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 2 14 Solid BC - Bare Copper Total Number of Conductors:2 Insulation Insulation Material: Insulation Trade Name Insulation Material Wall Thickness (mm) Flamarrest®LS PVC - Low Smoke Polyvinyl Chloride 0.254 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Nom. Wall Thickness (mm) Flamarrest®LS PVC - Low Smoke Polyvinyl Chloride 0.381 Outer Jacket Ripcord:Yes Overall Cable Overall Cabling Lay Length & Direction: Length (mm)Twists (twist/m) 82.549675 12.1397 Overall Cabling Color Code Chart: Number Color 1 Black 2 Red Overall Nominal Diameter:5.105 mm Mechanical Characteristics (Overall) Operating Temperature Range:0°C To +75°C UL Temperature Rating:75°C Bulk Cable Weight:52.087 Kg/Km Max. Recommended Pulling Tension:442.151 N Min. Bend Radius/Minor Axis:50.800 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification:FPLP NEC Articles:760 EU Directive 2011/65/EU (ROHS II):Yes EU CE Mark:Yes EU Directive 2000/53/EC (ELV):Yes Page 1 of 2 01-05-2017 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6120UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled EU Directive 2000/53/EC (ELV):Yes EU Directive 2002/95/EC (RoHS):Yes EU RoHS Compliance Date (mm/dd/yyyy):04/01/2005 EU Directive 2002/96/EC (WEEE):Yes EU Directive 2003/11/EC (BFR):Yes CA Prop 65 (CJ for Wire & Cable):Yes MII Order #39 (China RoHS):Yes Other Specification:California State Fire Marshall Flame Test UL Flame Test:NFPA 262 Suitability Suitability - Indoor:Yes Plenum/Non-Plenum Non-Plenum Number:5120UL Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 121.397 Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/km) 7.97283 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Description Current 10C Temperature Rise 8 Amps per conductor @ 25°C ambient Put Ups and Colors: Item #Putup Ship Weight Color Notes Item Desc 6120UL D151000 1,000 FT 37.000 LB BLUE C 2 #14 FLRST FLRST 6120UL 0011000 1,000 FT 37.000 LB BROWN 2 #14 FLRST FLRST 6120UL 002A1000 1,000 FT 38.000 LB RED 2 #14 FLRST FLRST 6120UL 0021000 1,000 FT 37.000 LB RED C 2 #14 FLRST FLRST 6120UL 002500 500 FT 18.500 LB RED 2 #14 FLRST FLRST 6120UL 0031000 1,000 FT 37.000 LB ORANGE 2 #14 FLRST FLRST 6120UL 0041000 1,000 FT 37.000 LB YELLOW 2 #14 FLRST FLRST 6120UL 0051000 1,000 FT 37.000 LB GREEN, DARK 2 #14 FLRST FLRST 6120UL 0071000 1,000 FT 37.000 LB VIOLET 2 #14 FLRST FLRST 6120UL 0091000 1,000 FT 37.000 LB WHITE 2 #14 FLRST FLRST 6120UL 0101000 1,000 FT 37.000 LB BLACK 2 #14 FLRST FLRST 6120UL 8771000 1,000 FT 37.000 LB NATURAL 2 #14 FLRST FLRST Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 08-12-2013 © 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 2 of 2 01-05-2017 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6120UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled For more Information please call 1-800-Belden1 General Description: Fire Alarm Cable, Plenum-FPLP, 2-16 AWG solid bare copper conductors with Flamarrest® insulation, Flamarrest®jacket with ripcord Usage (Overall) Suitable Applications:Fire Protection, Alarm, Signal, Monitor/Detection, Audio Circuits, Control Circuits, Initiating Circuits, Notification Circuits Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 2 16 Solid BC - Bare Copper Total Number of Conductors:2 Insulation Insulation Material: Insulation Trade Name Insulation Material Wall Thickness (mm) Flamarrest®LS PVC - Low Smoke Polyvinyl Chloride 0.203 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Nom. Wall Thickness (mm) Flamarrest®LS PVC - Low Smoke Polyvinyl Chloride 0.381 Outer Jacket Ripcord:Yes Overall Cable Overall Cabling Lay Length & Direction: Length (mm)Twists (twist/m) 69.849725 14.4364 Overall Cabling Color Code Chart: Number Color 1 Black 2 Red Overall Nominal Diameter:4.216 mm Mechanical Characteristics (Overall) Operating Temperature Range:0°C To +75°C UL Temperature Rating:75°C Bulk Cable Weight:34.973 Kg/Km Max. Recommended Pulling Tension:277.568 N Min. Bend Radius/Minor Axis:41.275 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification:FPLP NEC Articles:760 EU Directive 2011/65/EU (ROHS II):Yes EU CE Mark:Yes EU Directive 2000/53/EC (ELV):Yes Page 1 of 3 01-05-2017 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6220UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled EU Directive 2000/53/EC (ELV):Yes EU Directive 2002/95/EC (RoHS):Yes EU RoHS Compliance Date (mm/dd/yyyy):04/01/2005 EU Directive 2002/96/EC (WEEE):Yes EU Directive 2003/11/EC (BFR):Yes CA Prop 65 (CJ for Wire & Cable):Yes MII Order #39 (China RoHS):Yes Other Specification:California State Fire Marshall Flame Test UL Flame Test:NFPA 262 Plenum/Non-Plenum Plenum (Y/N):Yes Non-Plenum Number:5220UL Electrical Characteristics (Overall) Nom. Inductance: Inductance (µH/m) 0.49215 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 121.397 Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/km) 12.6319 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 6.3 Amps per conductor @ 25°C Put Ups and Colors: Item #Putup Ship Weight Color Notes Item Desc 6220UL D15U1000 1,000 FT 24.000 LB BLUE 2 #16 FLRST FLRST 6220UL D151000 1,000 FT 24.000 LB BLUE 2 #16 FLRST FLRST 6220UL 001U1000 1,000 FT 24.000 LB BROWN 2 #16 FLRST FLRST 6220UL 002A1000 1,000 FT 26.000 LB RED 2 #16 FLRST FLRST 6220UL 002U1000 1,000 FT 24.000 LB RED 2 #16 FLRST FLRST 6220UL 0021000 1,000 FT 24.000 LB RED C 2 #16 FLRST FLRST 6220UL 002500 500 FT 12.000 LB RED 2 #16 FLRST FLRST 6220UL 003C500 500 FT 11.000 LB ORANGE 2 #16 FLRST FLRST 6220UL 003U1000 1,000 FT 24.000 LB ORANGE 2 #16 FLRST FLRST 6220UL 004C500 500 FT 11.000 LB YELLOW 2 #16 FLRST FLRST 6220UL 004U1000 1,000 FT 24.000 LB YELLOW 2 #16 FLRST FLRST 6220UL 0041000 1,000 FT 24.000 LB YELLOW 2 #16 FLRST FLRST 6220UL 007U1000 1,000 FT 24.000 LB VIOLET 2 #16 FLRST FLRST 6220UL 0091000 1,000 FT 24.000 LB WHITE 2 #16 FLRST FLRST 6220UL 0101000 1,000 FT 24.000 LB BLACK 2 #16 FLRST FLRST Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 03-13-2013 © 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the Page 2 of 3 01-05-2017 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6220UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 3 of 3 01-05-2017 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6220UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled For more Information please call 1-800-Belden1 General Description: Fire Alarm Cable, Plenum-FPLP, 2-18 AWG solid bare copper conductors with Flamarrest® insulation, Flamarrest®jacket with ripcord Usage (Overall) Suitable Applications:Fire Protection, Alarm, Signal, Monitor/Detection, Audio Circuits, Control Circuits, Initiating Circuits, Notification Circuits Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 2 18 Solid BC - Bare Copper Total Number of Conductors:2 Insulation Insulation Material: Insulation Trade Name Insulation Material Wall Thickness (mm) Flamarrest®LS PVC - Low Smoke Polyvinyl Chloride 0.203 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Nom. Wall Thickness (mm) Flamarrest®LS PVC - Low Smoke Polyvinyl Chloride 0.381 Outer Jacket Ripcord:Yes Overall Cable Overall Cabling Lay Length & Direction: Length (mm)Twists (twist/m) 69.849725 14.4364 Overall Cabling Color Code Chart: Number Color 1 Black 2 Red Overall Nominal Diameter:3.658 mm Mechanical Characteristics (Overall) Operating Temperature Range:0°C To +75°C UL Temperature Rating:75°C Bulk Cable Weight:23.811 Kg/Km Max. Recommended Pulling Tension:174.369 N Min. Bend Radius/Minor Axis:38.100 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification:FPLP NEC Articles:760 EU Directive 2011/65/EU (ROHS II):Yes EU CE Mark:Yes EU Directive 2000/53/EC (ELV):Yes Page 1 of 3 01-05-2017 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6320UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled EU Directive 2000/53/EC (ELV):Yes EU Directive 2002/95/EC (RoHS):Yes EU RoHS Compliance Date (mm/dd/yyyy):04/01/2005 EU Directive 2002/96/EC (WEEE):Yes EU Directive 2003/11/EC (BFR):Yes CA Prop 65 (CJ for Wire & Cable):Yes MII Order #39 (China RoHS):Yes Other Specification:California State Fire Marshall Flame Test UL Flame Test:NFPA 262 Plenum/Non-Plenum Plenum (Y/N):Yes Non-Plenum Number:5320UL Electrical Characteristics (Overall) Nom. Inductance: Inductance (µH/m) 0.492 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 101.711 Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/km) 20.9984 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 5 Amps per conductor @ 25°C Put Ups and Colors: Item #Putup Ship Weight Color Notes Item Desc 6320UL D15C500 500 FT 7.500 LB BLUE 2 #18 FLRST FLRST 6320UL D151000 1,000 FT 17.000 LB BLUE C 2 #18 FLRST FLRST 6320UL 002U1000 1,000 FT 17.000 LB RED 2 #18 FLRST FLRST 6320UL 002U500 500 FT 9.000 LB RED 2 #18 FLRST FLRST 6320UL 0021000 1,000 FT 17.000 LB RED C 2 #18 FLRST FLRST 6320UL 003U1000 1,000 FT 17.000 LB ORANGE 2 #18 FLRST FLRST 6320UL 0031000 1,000 FT 17.000 LB ORANGE 2 #18 FLRST FLRST 6320UL 004U1000 1,000 FT 17.000 LB YELLOW 2 #18 FLRST FLRST 6320UL 0041000 1,000 FT 17.000 LB YELLOW 2 #18 FLRST FLRST 6320UL 005U1000 1,000 FT 17.000 LB GREEN, DARK 2 #18 FLRST FLRST 6320UL 0051000 1,000 FT 17.000 LB GREEN, DARK 2 #18 FLRST FLRST 6320UL 007C500 500 FT 7.500 LB VIOLET 2 #18 FLRST FLRST 6320UL 007U1000 1,000 FT 17.000 LB VIOLET 2 #18 FLRST FLRST 6320UL 009C500 500 FT 7.500 LB WHITE 2 #18 FLRST FLRST 6320UL 009U1000 1,000 FT 17.000 LB WHITE 2 #18 FLRST FLRST 6320UL 0091000 1,000 FT 17.000 LB WHITE 2 #18 FLRST FLRST 6320UL 010C500 500 FT 7.500 LB BLACK 2 #18 FLRST FLRST 6320UL 010U1000 1,000 FT 17.000 LB BLACK 2 #18 FLRST FLRST 6320UL 0101000 1,000 FT 17.000 LB BLACK 2 #18 FLRST FLRST 6320UL 012U1000 1,000 FT 17.000 LB PINK 2 #18 FLRST FLRST Notes: C = CRATE REEL PUT-UP. Page 2 of 3 01-05-2017 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6320UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled Revision Number: 2 Revision Date: 03-13-2013 © 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 3 of 3 01-05-2017 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6320UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled For more Information please call 1-800-Belden1 General Description: Fire Alarm Cable, Plenum-FPLP, 2-18 AWG solid bare copper conductors with FEP insulation, Overall Beldfoil® shield, Flamarrest®jacket with ripcord Usage (Overall) Suitable Applications:Addressable Fire Systems, Data Circuits, Monitor/Detection, Control Circuits, Initiating Circuits, Notification Circuits Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 2 18 Solid BC - Bare Copper Total Number of Conductors:2 Insulation Insulation Material: Insulation Material Wall Thickness (mm) FEP - Fluorinated Ethylene Propylene 0.4572 Outer Shield Outer Shield Material: Outer Shield Trade Name Outer Shield Material Coverage (%) Beldfoil®Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 20 (7x28)TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Nom. Wall Thickness (mm) Flamarrest®LS PVC - Low Smoke Polyvinyl Chloride 0.381 Outer Jacket Ripcord:Yes Overall Cable Overall Cabling Lay Length & Direction: Length (mm)Twists (twist/m) 63.49975 15.7488 Overall Cabling Color Code Chart: Number Color 1 Black 2 Red Overall Nominal Diameter:4.699 mm Mechanical Characteristics (Overall) Operating Temperature Range:0°C To +75°C UL Temperature Rating:75°C Bulk Cable Weight:31.252 Kg/Km Max. Recommended Pulling Tension:236.644 N Min. Bend Radius/Minor Axis:47.625 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification:FPLP NEC Articles:760 Page 1 of 2 01-05-2017 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6320FK Multi-Conductor - Commercial Applications, Addressable Systems - 2 Cond Cabled EU Directive 2011/65/EU (ROHS II):Yes EU CE Mark:Yes EU Directive 2000/53/EC (ELV):Yes EU Directive 2002/95/EC (RoHS):Yes EU RoHS Compliance Date (mm/dd/yyyy):04/01/2005 EU Directive 2002/96/EC (WEEE):Yes EU Directive 2003/11/EC (BFR):Yes CA Prop 65 (CJ for Wire & Cable):Yes MII Order #39 (China RoHS):Yes Other Specification:California State Fire Marshall Flame Test UL Flame Test:NFPA 262 Plenum/Non-Plenum Plenum (Y/N):Yes Electrical Characteristics (Overall) Nom. Inductance: Inductance (µH/m) 0.62339 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 85.306 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 153.551 Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/km) 20.9984 Nominal Outer Shield DC Resistance: DCR @ 20°C (Ohm/km) 49.871 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 8 Amps per conductor @ 25°C Put Ups and Colors: Item #Putup Ship Weight Color Notes Item Desc 6320FK 002U1000 1,000 FT 26.000 LB RED Z 2 #18 FEP FS FLRST 6320FK 0021000 1,000 FT 27.000 LB RED C 2 #18 FEP FS FLRST Notes: C = CRATE REEL PUT-UP. Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. Revision Number: 2 Revision Date: 01-19-2015 © 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 2 of 2 01-05-2017 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6320FK Multi-Conductor - Commercial Applications, Addressable Systems - 2 Cond Cabled