Loading...
HomeMy WebLinkAboutAPPROVED PLANS - 22-00391 - 618 Vale Ln - Solar PanelsAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Alex Owens Alex.Owens@rexburg.org 208-372-2330 Description : 618 Vale Ln - Solar Panels Address : 618 Vale Ln Record Type : Solar Panels Document Filename : Nicholas Robinson Permit 5.23.2022(2).pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 22-00391 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments PV01 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector PV02 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector PV01 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector PV03 Callout Alex Owens : Electrical Open 3 Where this is a line-side tap system, the disconnect needs to have neutral and grounding electrode conductor bonded as per 250.24A1 Solar Panels Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) WIRING SHALL NOT BE INSTALLED WITHIN 10" OF ROOF DECKING EXCEPT WHERE DIRECTLY BELOW THE ROOF SURFACE COVERED BY PV MODULES AND/OR EQUIPMENT MODULE AND INVERTER(S) PLEASE REFER TO LABEL PLAN FOR WARNINGS PER NEC 690 & IRC 2018 SCOPE OF WORK Wiring must be properly supported by devices or mechanical means designed and listed for such use. Wiring must be permanently and completely held off of the roof surface. NEC 110 NOTES NAPCEP HOLDER & CERT # UT. CONTRACTORS LICENSE # & TYPE APPLICABLE CODES Michael Allen - 032611-4 Michael Telford - 092411-142 #7426030.5501 Class LRF, B100, S200, S202 2018 International Building Code (IBC) SHEET INDEX Enphase Micro-Inverters (IQ7+) 2017 National Electric Code (NEC) SYSTEM IS "RAPID SHUTDOWN" COMPLIANT REC 365W STREET VIEW VICINITY MAP Total Area of Array(s): 504ft² Pass Through Boxes Mounted Flush on Installation Surface (26.5º) System Size: 10.22kW Meter Upgrade: NO - Pass Through Breaker Standard Asphalt Shingle Roof Array(s) Azimuth: 175º Anchored on 48" Centers using UL Listed Snap N Rack UR-40 System 2018 International Residential Code (IRC) (28) (28) TITLE SHEET SITE PLAN ELECTRICAL LINE DIAGRAM EQUIPMENT LABELS ARRAY DETAILS (SITE DEPENDENT) INSTALLATION/METER DETAIL PV01 PV02 PV03 PV04 PV05 PV06 PV07 SITE DIRECTORY SHEET # SCALE: IN T E R M O U N T A I N W I N D & S O L A R 10 4 1 N 9 5 0 W S U I T E 5 0 0 CE N T E R V I L L E , U T 8 4 0 1 4 P: 8 0 1 - 2 9 8 - 5 2 5 5 F: 8 0 1 - 2 9 8 - 5 3 5 5 PR O J E C T # SY S T E M S I Z E : AH J : DA T E : 20 2 2 - 3 6 7 - I D 10 . 2 2 k W - ( 2 8 ) M o d u l e s Re x b u r g 05 / 2 3 / 2 0 2 2 De s i g n e r Re v i s i o n Ni c h o l a s R o b i n s o n 61 8 V a l e L n , R e x b u r g , I D 8 3 4 4 0 J. T o o n e Michael Telford - 092411-142 PV01 N.T.S 90 120 150 180 210 240 270 300 330 0 30 60 W E S N 80 70 50 4O 2010350 320 310 290 280 260 250 230 220 200 190 170 160 140 130 110 100 340 AZIMUTH LEGEND PV/AC DISCONNECT SUB PANELSB HOME LOAD PANELLP UTILITY METER MAIN M ROOFTOP JUNCTION BOX 36"/18" FIRE CODE CLEARANCE PRODUCTION METER P PASS THROUGH BREAKER AC PV MODULE TRENCHING (1) 2" SCH. 40, (1) 1" SCH. 40 PV @ 2' DEPTH PROPERTY LINE *GROUND MOUNTED SYSTEMS SHALL MAINTAIN MINIMUM 10' SETBACK FROM PROP. LINES PV BRANCH CIRCUIT PTB BALLASTED RACKING PV COMBINER C ESS DISCONNECTBD 51'-5" WIRING SHALL NOT BE INSTALLED WITHIN 10" OF ROOF DECKING EXCEPT WHERE DIRECTLY BELOW THE ROOF SURFACE COVERED BY PV MODULES AND/OR EQUIPMENT MODULE AND INVERTER(S) PLEASE REFER TO LABEL PLAN FOR WARNINGS PER NEC 690 & IRC 2018 SCOPE OF WORK Wiring must be properly supported by devices or mechanical means designed and listed for such use. Wiring must be permanently and completely held off of the roof surface. NEC 110 NOTES Enphase Micro-Inverters (IQ7+) SYSTEM IS "RAPID SHUTDOWN" COMPLIANT REC 365W Total Area of Array(s): 504ft² Pass Through Boxes Mounted Flush on Installation Surface (26.5º) System Size: 10.22kW Meter Upgrade: NO - Pass Through Breaker Standard Asphalt Shingle Roof Array(s) Azimuth: 175º Anchored on 48" Centers using UL Listed Snap N Rack UR-40 System (28) (28) M SB AC PTB C SHEET # SCALE: IN T E R M O U N T A I N W I N D & S O L A R 10 4 1 N 9 5 0 W S U I T E 5 0 0 CE N T E R V I L L E , U T 8 4 0 1 4 P: 8 0 1 - 2 9 8 - 5 2 5 5 F: 8 0 1 - 2 9 8 - 5 3 5 5 PR O J E C T # SY S T E M S I Z E : AH J : DA T E : 20 2 2 - 3 6 7 - I D 10 . 2 2 k W - ( 2 8 ) M o d u l e s Re x b u r g 05 / 2 3 / 2 0 2 2 De s i g n e r Re v i s i o n Ni c h o l a s R o b i n s o n 61 8 V a l e L n , R e x b u r g , I D 8 3 4 4 0 J. T o o n e Michael Telford - 092411-142 PV02 1 16" = 1' 9 8 J-BOX TYPICAL SOLAR PANELS CONNECTED TO MICROINVERTERS 8 NEMA 4 J-BOX 6"x6"x3" 60A 120/240V FUSED DISCONNECT (2) 50A Fuses (1 OF 1) 80A ENPHASE IQ COMBINER 3 EXISTING METER MAIN COMBO 200A 240 / 120 TO GRID G L1L2 L1L2 BI-DIRECTIONAL UTILITY METER N Ho m e A C L o a d C e n t e r 20 0 A 2 4 0 / 1 2 0 MCB 200A - 2P N L1L2 G NG PTB 200A - 2P (1)3/ 4" EMT (3)#8THWN-2 (1)#10THWN-2 EG 20A - 2P 20A - 2P 20A - 2P FACTORY INSTALLED 2P MONITORING BREAKER (15A or 10A) (1)2" EMT (3)#3/0THWN-2 CU (1)#6THWN-2 EG (1)2" EMT (3)#3/0THWN-2 CU (1)#6THWN-2 EG (1)3/ 4" EMT (3)#8THWN-2 (1)#10THWN-2 EG (1)3/ 4" EMT (6)#10THWN-2 (1)#10THWN-2 EG INTERCONNECTION PCC MADE IN EXISTING EXTERIOR 240VAC, 200AAC 1 PHASE METER MAIN PANEL WITH SUPPLY SIDE FEEDERS. TAP WILL USE INSULATED PIERCING CONNECTER (NSI INDUSTRIES) WITH 60AAC FUSED DISCONNECT WITH 50A FUSES AS OCPD. THIS CONNECTION SHALL BE MADE IN CONFORMANCE WITH 2017 NEC 705.12. 33.9A 240V PHOTOVOLTAIC AC OUTPUT LABEL AC OUTPUT CURRENT NOMINAL AC VOLTAGE ELECTRICAL NOTES: 1. ALL COMPONENTS ARE GROUNDED PER NEC 2017 CODE 2. INTERCONNECTION METHOD COMPLIES WITH NEC 690 3. ALL WIRES WILL BE RATED THHN/THWN-2 4. ALL INTERCONNECTION WILL COMPLY WITH NEC 705.12 RAPID SHUTDOWN SWITCH FOR PV SYSTEM PLEASE REFER TO PV06 FOR REFERENCE PHOTOS * ACTUAL AC/DC WIRING AND/OR CONDUIT BODY TO BE DETERMINED IN FIELD. MAY BE REPLACED BYNMB/MC CABLE. INVERTER SPECIFICATIONS MANUFACTURER Enphase Energy MODEL IQ7PLUS-72-2-US MAX DC INPUT VOLTAGE 60 V MAX OUTPUT POWER 290 W NOMINAL AC OUTPUT VOLTAGE 240 V NOMINAL AC OUTPUT CURRENT 1.21 A MAX FUSE (OCPD)20 A PV MODULE SPECIFICATIONS MANUFACTURER REC MODEL 365W MAX POWER-POINT CURRENT (Imp)9.60 A MAX POWER-POINT VOLTAGE (Vmp)38.0 V OPEN CIRCUIT VOLTAGE (Voc)44.3 V SHORT CIRCUIT CURRENT (Isc)10.26 A MAX SERIES FUSE (OCPD)25 A MAX POWER (Pmax)365 W MAX VOLTAGE (Vdc)1000 V * ARRAY COMPLIES WITH 2017 NEC 690.12 INDOOR/OUTDOOR TRANSITION/PULL BOX LOCATION TBD IN FIELD DISCONNECT(S) TO BE GROUPED WITHIN 3' FEET OF METER MAIN FREE AIR (3) ENPHASE Q - CABLE (1)#6 BARE COPPER EG (1) 3/ 4" EMT (6)#10THWN-2 (1)#10THWN-2 EG SHEET # SCALE: IN T E R M O U N T A I N W I N D & S O L A R 10 4 1 N 9 5 0 W S U I T E 5 0 0 CE N T E R V I L L E , U T 8 4 0 1 4 P: 8 0 1 - 2 9 8 - 5 2 5 5 F: 8 0 1 - 2 9 8 - 5 3 5 5 PR O J E C T # SY S T E M S I Z E : AH J : DA T E : 20 2 2 - 3 6 7 - I D 10 . 2 2 k W - ( 2 8 ) M o d u l e s Re x b u r g 05 / 2 3 / 2 0 2 2 De s i g n e r Re v i s i o n Ni c h o l a s R o b i n s o n 61 8 V a l e L n , R e x b u r g , I D 8 3 4 4 0 J. T o o n e Michael Telford - 092411-142 PV03 N.T.S there=this=is=a=lineJside=tap= systemI=the=disconnect=needs= to=have=neutral=and=grounding= electrode=conductor=bonded= as=per=ORMKOQAN= MICRO INVERTER SYSTEM SIGNAGE *All signage must be permanently attached and be able to withstand the environment they are installed. Signage also cannot be hand-written. NEC 110. A sign is required at the service panel stating that the home has a solar PV system as an additional power source. This sign is required to be located next to the PV backfed breaker(s) ONLY if the 120% allowance of NEC 705.12 PV SYSTEM: AC Current = 33.9A AC Volts = 240V This sign is required to be located at the back-fed panelboard. This sign must be reflective and is required to be located next to the disconnect switch which activates rapid shutdown. This sign is required to be located at the backfed panelboard. SOLAR METER PARALLEL GENERATION ON SITE *PLACARD REQUIRED BY UTILITY *PLACARD REQUIRED BY UTILITY MANUAL DISCONNECT FOR PARALLEL GENERATION WITHIN 10' OF METER WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING INVERTER OUTPUT CONNECTION, DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING This sign to be located on the outside of, and within 3’ of the service equipment. RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM Must be provided next to the rapid shutdown disconnect for this system. *IF ESS SYSTEM PRESENT REMOVE THIS LABEL ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PV SYSTEM DISCONNECT Must be provided on distrubution equipment NEC 705.12 (B) (3) (3) SHEET # SCALE: IN T E R M O U N T A I N W I N D & S O L A R 10 4 1 N 9 5 0 W S U I T E 5 0 0 CE N T E R V I L L E , U T 8 4 0 1 4 P: 8 0 1 - 2 9 8 - 5 2 5 5 F: 8 0 1 - 2 9 8 - 5 3 5 5 PR O J E C T # SY S T E M S I Z E : AH J : DA T E : 20 2 2 - 3 6 7 - I D 10 . 2 2 k W - ( 2 8 ) M o d u l e s Re x b u r g 05 / 2 3 / 2 0 2 2 De s i g n e r Re v i s i o n Ni c h o l a s R o b i n s o n 61 8 V a l e L n , R e x b u r g , I D 8 3 4 4 0 J. T o o n e Michael Telford - 092411-142 PV05 N.T.S METER WALL HOME LOAD PANEL EXISTING SITE PHOTOS ATTIC DETAIL SHEET # SCALE: IN T E R M O U N T A I N W I N D & S O L A R 10 4 1 N 9 5 0 W S U I T E 5 0 0 CE N T E R V I L L E , U T 8 4 0 1 4 P: 8 0 1 - 2 9 8 - 5 2 5 5 F: 8 0 1 - 2 9 8 - 5 3 5 5 PR O J E C T # SY S T E M S I Z E : AH J : DA T E : 20 2 2 - 3 6 7 - I D 10 . 2 2 k W - ( 2 8 ) M o d u l e s Re x b u r g 05 / 2 3 / 2 0 2 2 De s i g n e r Re v i s i o n Ni c h o l a s R o b i n s o n 61 8 V a l e L n , R e x b u r g , I D 8 3 4 4 0 J. T o o n e Michael Telford - 092411-142 PV06 N.T.S N CAUTION: MULTIPLE SOURCES OF POWER PERMANENT PLAQUE OR DIRECTORY INSTALLED AT EACH SERVICE EQUIPMENT LOCATION NEC 705.10 UTILITY METER MAIN LOAD PANEL MANUAL DISCONNECT FOR SOLAR GENERATION PV HOUSE DRIVEWAY VALE ST M I L L R A C E R D SHEET # SCALE: IN T E R M O U N T A I N W I N D & S O L A R 10 4 1 N 9 5 0 W S U I T E 5 0 0 CE N T E R V I L L E , U T 8 4 0 1 4 P: 8 0 1 - 2 9 8 - 5 2 5 5 F: 8 0 1 - 2 9 8 - 5 3 5 5 PR O J E C T # SY S T E M S I Z E : AH J : DA T E : 20 2 2 - 3 6 7 - I D 10 . 2 2 k W - ( 2 8 ) M o d u l e s Re x b u r g 05 / 2 3 / 2 0 2 2 De s i g n e r Re v i s i o n Ni c h o l a s R o b i n s o n 61 8 V a l e L n , R e x b u r g , I D 8 3 4 4 0 J. T o o n e Michael Telford - 092411-142 PV06 N.T.S