HomeMy WebLinkAboutEXTERIOR SIGNAGE Rev (1) 12.13.20238
A2.1
_______
19.21 SF
2'
-
8
"
1'
-
0
"
8"
1'
-
0
"
5 1/2"
7'-2 1/4"
6'-2"
ADDRESS SIGNAGE
NOTE:
SQUARE FOOTAGE NOT
INCLUDED IN BUILDING
SIGNAGE SCHEDULE
1'
-
0
"
8
A2.1
_______
1450
16.25 SF
10'-10"
1'
-
6
"
8
A2.1
_______
13.56 SF
9'-0 1/2"
1'
-
6
"
8
A2.1
_______
8
A2.1
_______
20.67 SF
2'
-
0
"
10'-4"
12'-2 1/2"
40.83 SF
3'
-
4
1
/
4
"
2'
-
6
"
1'-1 1/2"INTERNALLY ILLUMINATED
9
-
A2
.
1
NOTE TO SIGN INSTALLER:
ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED
IF MOUNTING THROUGH PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR
OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH NEAREST
ALTERNATE MOUNTING HOLE, PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES
NOTE:
ALL SIGN PENETRATIONS ABOVE ROOF LEVEL
MUST BE A CLEAR MINIMUM OF 8" ABOVE DECK
2'
-
6
"
2'-6"
8
A2.1
_______
SIGNAGE GENERAL NOTES
1. SIGNAGE FURNISHED BY WAL-MART AND INSTALLED BY
GC.
2. ALL EXISTING WALMART EXTERIOR SIGNAGE IS TO REMAIN
IN PLACE ON BUILDING UNTIL GC SIGN COMPANY IS
ONSITE. EXISTING SIGNAGE WILL THEN BE REMOVED,
PATCH AND REPAIR WORK WILL BE COMPLETED AT SIGN
LOCATIONS, AND SIGNAGE WILL BE INSTALLED PER
PLANS.
A. A TEMPORARY BANNER WILL BE INSTALLED PRIOR TO
REMOVAL OF EXISTING EXTERIOR SIGNAGE. BANNER
WILL REMAIN IN PLACE UNTIL ALL MODIFICATIONS
AND/OR REPAIRS HAVE BEEN COMPLETED AND
SIGNAGE IS INSTALLED.
B. TEMPORARY BANNER WILL BE APPROXIMATELY 125 SF
(5'X25').
C. EXTERIOR SIGN WORK NEEDS TO BE SCHEDULED,
COORDINATED, AND COMPLETED DURING WEEK 6 OF
CONSTRUCTION SCHEDULE.
3. GENERAL CONTRACTOR RESPONSIBILITIES
A. BY END OF FIRST WEEK OF CONSTRUCTION, REVIEW
EXISTING CONSTRUCTION WHERE SIGN(S) WILL BE
INSTALLED. IF EXISTING CONDITIONS DO NOT MATCH
SIGN ATTACHMENT DETAILS SHOWN, REQUEST
APPROVAL FROM CONSTRUCTION MANAGER TO
SUBMIT RFI IN ACCORDANCE WITH SECTION 01255.
NOTE DIFFERENCES IN CONSTRUCTION, INCLUDING
DIMENSIONS, AND INCLUDE PHOTOGRAPHS FOR
CLARIFICATION.
B. PROVIDE SUBSTRATE SUITABLE FOR INSTALLATION OF
SIGNAGE. REFER TO SIGN DETAILS FOR LIGHTED
ID/LOGO SIGNS.
C. PROVIDE JUNCTION BOXES AND CIRCUITRY TO
"Walmart" and "spark" SIGNAGE. EXISTING (8) BOXES
FROM "WAL«MART" SIGNAGE MAY BE REUSED.
D. PROVIDE JUNCTION BOXES AND CIRCUITRY TO
TENANT SIGNAGE LOCATION SHOWN. REFER TO
ELECTRICAL.
E. INSTALL ACCESS DOORS AND FRAMES IN GYPSUM
BOARD CEILINGS IF REQUIRED BY RELOCATION OF
EXISTING TENANT SIGNAGE.
F. VERIFY VOLTAGE AT CIRCUITS FEEDING LIGHTED
SIGNAGE. REFER TO ELECTRICAL
G. MAKE FINAL TERMINATIONS ON LIGHTED SIGNAGE.
H. REMOVE ALL LIT ID/LOGO SIGNS AND UNLIT EXTERIOR
STUD MOUNTED BUILDING SIGNS. UNLESS NOTED
OTHERWISE.
I. MAKE REQUIRED EXTERIOR WALL PENETRATIONS,
INSTALL CONDUIT, AND SEAL PENETRATIONS PER
SPECIFICATION SECTION 07900.
J. INSTALL SIGNAGE PER DETAILS.
EXISTING CMU
PLASTIC NON-ILLUMINATED
CHANNEL LETTER BY
WALMART
INSTALL 1/8" DIA ALL-THREAD
STUDS INTO PLASTIC
MOUNTS PRIOR TO SIGN
INSTALLATION
3/8" DIA HOLE FILLED WITH
ADHESIVE SEALANT. COAT
ALL-THREAD STUD WITH
ADHESIVE SEALANT PRIOR
TO WALL ATTACHMENT
MOUNTING HOLE PATTERNS FOR
NON-ILLUMINATED SIGN INSTALLATION
PROVIDED BY WALMART
PLASTIC MOUNT FOR ALL-
THREAD STUD TYP BY WALMART
"ADHESIVE SEALANT" IS TO
BE PRODUCT LN-950 BY
LIQUID NAILS OR SIMILAR
POLYURETHANE
CONSTRUCTION ADHESIVE,
MEETING ASTM D3498 AND
C557 STANDARDS,
EXTERIOR APPLICATION,
WEATHER RESISTANT,
LOW VOC, WITH A MINIMUM
SHEAR STRENGTH OF 250
PSI
VA
R
I
E
S
THROUGH WALL
PROTECTION TUBE
FURNISHED BY WALMART
INSTALLED BY GC PER
MFR RECOMMENDATIONS
FULL BED OF MULTI-
COMPONENT SEALANT AT
PERIMETER OF CONDUIT
INSTALL LETTER BACK
PRIOR TO INSTALLATION
INDIVIDUAL PLASTIC
ILLUMINATED CHANNEL
LETTERS
INSTALL LETTER FACES
WITH SET SCREWS,
TYP LOCATE ANCHORS AND
WIRING/CONDUIT PENETRATIONS
PER SIGN ATTACHMENT TEMPLATE
PROVIDED BY WALMART
LOCATE CONDUIT PENETRATION
4'-0" MAX FROM UNISTRUT
PROVIDE ONLY ONE ROOF
PENETRATION FOR ALL WHIPS
EXISTING ROOFING SYSTEM
PENETRATIONS AND SEALANT
AT LOW VOLTAGE WIRE
3/4" LIQUID TIGHT FLEXIBLE METAL
CONDUIT
SIGNAGE CONDUIT FLASHING AT LOW VOLTAGE
WIRE PENETRATIONS FURNISHED BY WALMART
INSTALLED BY GC PER MFR RECOMMENDATIONS
SEALANT AT PERIMETER AND ANCHORS OF
REMOTE POWER SUPPLY ENCLOSURE
REMOTE POWER SUPPLY ENCLOSURE
EXISTING
WATERPROOFING MEMBRANE
HILTI HPS 1/4" X 1 5/8"
SLEEVE ANCHOR
PROVIDED BY WALMART
AT EACH SIGN
CONNECTION POINT
INSTALLED BY GC
PRE MOLDED PIPE FLASHING ATTACHED
PER ROOFING MFR RECOMMENDATIONS
CONT SEALANT
LOW VOLTAGE WIRE
CONDUIT TO PANEL
BOARD REF ELECTRICAL
8"
M
I
N
Ga
l
l
o
w
a
y
&
C
o
m
p
a
n
y
,
I
n
c
.
A
l
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
55
0
0
G
r
e
e
n
w
o
o
d
P
l
a
z
a
B
l
v
d
,
S
t
e
.
2
0
0
Gr
e
e
n
w
o
o
d
V
i
l
l
a
g
e
,
C
O
8
0
1
1
1
30
3
.
7
7
0
.
8
8
8
4
•Ga
l
l
o
w
a
y
U
S
.
c
o
m
SHEET:
DRAWN BY:
CHECKED BY:
PROTO CYCLE:
DOCUMENT DATE:
CO
N
S
U
L
T
A
N
T
S
ST
I
P
U
L
A
T
I
O
N
F
O
R
R
E
U
S
E
PR
O
T
O
:
JO
B
N
U
M
B
E
R
:
TH
I
S
D
R
A
W
I
N
G
W
A
S
P
R
E
P
A
R
E
D
F
O
R
US
E
O
N
A
S
P
E
C
I
F
I
C
S
I
T
E
A
T
:
CO
N
T
E
M
P
O
R
A
N
E
O
U
S
L
Y
W
I
T
H
I
T
S
I
S
S
U
E
DA
T
E
O
N
A
N
D
I
T
I
S
N
O
T
SU
I
T
A
B
L
E
F
O
R
U
S
E
O
N
A
D
I
F
F
E
R
E
N
T
PR
O
J
E
C
T
S
I
T
E
O
R
A
T
A
L
A
T
E
R
T
I
M
E
.
U
S
E
OF
T
H
I
S
D
R
A
W
I
N
G
F
O
R
R
E
F
E
R
E
N
C
E
O
R
EX
A
M
P
L
E
O
N
A
N
O
T
H
E
R
P
R
O
J
E
C
T
RE
Q
U
I
R
E
S
T
H
E
S
E
R
V
I
C
E
S
O
F
P
R
O
P
E
R
L
Y
LI
C
E
N
S
E
D
A
R
C
H
I
T
E
C
T
S
A
N
D
E
N
G
I
N
E
E
R
S
.
RE
P
R
O
D
U
C
T
I
O
N
O
F
T
H
I
S
D
R
A
W
I
N
G
F
O
R
RE
U
S
E
O
N
A
N
O
T
H
E
R
P
R
O
J
E
C
T
I
S
N
O
T
AU
T
H
O
R
I
Z
E
D
A
N
D
M
A
Y
B
E
C
O
N
T
R
A
R
Y
T
O
TH
E
L
A
W
.
12
/
1
3
/
2
0
2
3
4
:
2
5
:
4
7
P
M
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
W
M
T
-
F
S
P
a
i
n
t
(
v
2
2
)
/
0
1
8
7
8
_
R
e
x
b
u
r
g
_
ID
_
1
8
2
_
R
_
A
R
C
H
_
V
2
2
.
r
v
t
A2.1
EXTERIOR
DETAILS AND
SIGNAGE
WM
T
0
0
1
8
7
8
.
3
1
RE
X
B
U
R
G
,
I
D
12
/
0
1
/
2
3
12/01/23
ST
O
R
E
N
O
:
0
1
8
7
8
18
2
09/29/23
RE
X
B
U
R
G
,
I
D
FS PAINT
14
5
0
N
2
N
D
E
A
S
T
1/4" = 1'-0"2 SIGNAGE
1/4" = 1'-0"3 SIGNAGE
1/4" = 1'-0"5 SIGNAGE
1/4" = 1'-0"6 SIGNAGE
1/4" = 1'-0"4 SIGNAGE
1/4" = 1'-0"1 SIGNAGE
1/4" = 1'-0"7 SIGNAGE
1 1/2" = 1'-0"8 SIGN ATTACHMENT AT CMU WALL
1 1/2" = 1'-0"9 SIGNAGE ATTACHMENT
EXISTING SIGN SCHEDULE
SIGNAGE QTY COLOR SIZE - TYPE
INDIVIDUAL
AREA (SF)
TOTAL AREA
(SF)
AUTO CENTER SIGNAGE
Automotive 1 WHITE 2'-0" 27.75 27.75
Automotive Numeral 1 1 WHITE 1'-6" 1.77 1.77
Automotive Numeral 2 1 WHITE 1'-6" 1.77 1.77
Automotive Numeral 3 1 WHITE 1'-6" 1.77 1.77
AUTO CENTER SIGNAGE 33.06
FRONT SIGNAGE
Automotive 1 WHITE 2'-0" 27.75 27.75
Grocery 1 WHITE 2'-6" 6.56 6.56
Home & Pharmacy 1 WHITE 2'-6" 15.19 15.19
OUTDOOR 1 WHITE 2'-6" 31.8 31.8
Pickup 1 YELLOW/WHIT
E
2'-6" 65.43 65.43
SPARK WM 1 WHITE/YELLO
W
12'-0" 244.6 244.6
FRONT SIGNAGE 391.33
PHARAMACY DRIVE THRU SIGNAGE
Pharmacy Drive Thru 2 WHITE 1'-6" 37.71 75.41
PHARAMACY DRIVE THRU SIGNAGE 75.41
REAR SIGNAGE
SPARK WM 1 WHITE/YELLO
W
12'-0" 244.6 244.6
REAR SIGNAGE 244.6
TOTAL BUILDING SIGNAGE 744.41
PROPOSED SIGNAGE SCHEDULE
SIGNAGE QTY COLOR SIZE SIZE - TYPE
INDIVIDUAL
AREA (SF)
TOTAL AREA
(SF)
EXISTING OR
NEW
REAR SIGNAGE
SPARK WM 1 WHITE/YELLOW 12'-0" 12'-0" 244.6 244.6 Existing
REAR SIGNAGE 244.6
PHARAMACY DRIVE THRU SIGNAGE
Pharmacy Drive
Thru
2 WHITE 1'-6" 1'-6" 37.71 75.41 Existing
PHARAMACY DRIVE THRU SIGNAGE 75.41
FRONT SIGNAGE
ADDRESS 1 WHITE 1'-0" WHITE 0 0 New Construction
Auto Care with
Arrow
1 WHITE 1'-6" 1'-6" 16.25 16.25 New Construction
Grocery 1 WHITE 2'-6" 2'-6" 6.56 6.56 Existing
Home & Pharmacy 1 WHITE 2'-6" 2'-6" 15.19 15.19 Existing
OUTDOOR 1 WHITE 2'-0" 2'-0" 20.35 20.35 New Construction
Pharmacy Drive
Thru
1 WHITE 1'-6" Stacked 1'-6" 39.42 39.42 New Construction
Pickup with Arrow 1 WHITE 2'-6" 2'-6" 40.83 40.83 New Construction
SPARK WM 1 WHITE/YELLOW 12'-0" 12'-0" 244.6 244.6 Existing
FRONT SIGNAGE 383.2
AUTO CENTER SIGNAGE
Auto Center 1 WHITE 1'-6" 1'-6" 13.88 13.88 New Construction
Automotive
Numeral 1
1 BLACK 1'-6" BLACK 1'-6" 1.77 1.77 New Construction
Automotive
Numeral 2
1 BLACK 1'-6" BLACK 1'-6" 1.77 1.77 New Construction
Automotive
Numeral 3
1 BLACK 1'-6" BLACK 1'-6" 1.77 1.77 New Construction
AUTO CENTER SIGNAGE 19.19
Clearance 1 BLACK 6" 0 0 New Construction
0
TOTAL BUILDING SIGNAGE 722.4
ISSUE BLOCK