HomeMy WebLinkAboutPLANS - 23-00937 - Madison Health Surgery Center - Mechanical1/4"=1'-0" PARTIAL HVAC DEMO PLAN SCALE: EXISTING RTU-2 TO TO BE REMOVED AND REPLACED WITH NEW HALL CLEAN UTIL. / STERILE O.R.#1 O.R.#2 BREAK ROOM HALL HALL VEST. VEST. DSSG. T.R. RECOVERY ROOM PREP. SOILED HOLDING RECIEVING STOR. PATIENT EXIT OFFICE CONSULT PREP T.R.REC'P BUSINESS OFFICE WAITING STOR. W.LKR ROOM T.R. FIRE RISER T.R. M.LKR ROOM PREP HALL MECH. CUST. MED GAS ANTH. ROOM SOILED EXISTING RTU-1 TO TO BE REMOVED AND REPLACED WITH NEW EXISTING RETURN AIR EXISTING RETURN AIR EXISTING RETURN AIR EX I S T I N G R E T U R N A I R EX I S T I N G R E T U R N A I R EX I S T I N G R E T U R N A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR EXISTING SUPPLY AIR EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR DEMO EXISTING DUCT WORK AS INDICATED. CAP AND SEAL PENETRATION AT EXISTING TO REMAIN (TYP.) EX I S T I N G R E T U R N A I R DEMO EXISTING DUCT WORK AS INDICATED. CAP AND SEAL PENETRATION AT EXISTING TO REMAIN (TYP.) DEMO DEMO DEMOEXISTING SUPPLY AIR CA P / S E A L EX I S T I N G EX EF EX EF150 CFM 200 CFM MECHANICAL LEGEND SYMBOL DUCTWORK DESCRIPTION DUCTWORK BREAK DUCTWORK OR PIPING RISE CONCENTRIC SQUARE TO ROUND TRANSITION MOTORIZED DAMPERM MANUAL VOLUME DAMPER SPIN-IN FITTING W/ AIR EXTRACTOR AND HAND DAMPERair flow HIGH EFFICIENCY FITTING W/ HAND DAMPERair flow SWITCH THERMOSTATT COMBINATION SMOKE/FIRE DAMPER FIRE DAMPER SUPPLY DIFFUSER RETURN GRILLE EXHAUST GRILLE FLEXIBLE DUCTWORK GENERAL NOTES: 1.VERIFY ALL PROJECT SITE DIMENSIONS AND CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 2.ALL APPLICABLE BUILDING CODES SHALL BE FOLLOWED FOR PERFORMANCE OF THIS WORK. 3.INSTALLATION OF ALL DUCTWORK SHALL FOLLOW APPLICABLE SMACNA STANDARDS 4.FLEX DUCT LENGTH SHALL NOT EXCEED 6 FT. 5.DUCT DIMENSIONS SHOWN ON THE DRAWINGS INDICATE INSIDE FREE AREA. DUCT LINER SHALL BE ADDED TO OVERALL DIMENSION OF THE DUCT. 6.SPECIAL CONDITIONS APPLY TO ALL DUCTWORK AND PIPING PASSING THROUGH FIRE RATED WALLS. SEE APPLICABLE FIRE CODE FOR FIRE STOPPING REQUIREMENTS. 7.ALL REQUIRED MECHANICAL AND ELECTRICAL EQUIPMENT AND DEVICE ACCESSES SHALL BE MAINTAINED TO THE APPLICABLE CODES FOR ALL MECHANICAL ITEMS SHOWN. 8.REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS AND MOUNTING HEIGHTS OF THERMOSTATS. 9.MECHANICAL OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED IN A THREE RING BINDER CONTAINING SUBMITTALS, INSTRUCTIONS, AND WARRANTY (3) REQUIRED. 10.ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED, AND BALANCED BY A CERTIFIED PROFESSIONAL TESTING AGENCY (NEBB). 11.VERIFY THAT ALL ROOFTOP EQUIPMENT THAT REQUIRE SERVICING IS NO CLOSER THAN TEN FEET TO ROOF EDGE. A SAFETY RAILING IS REQUIRED FOR ALL EQUIPMENT LESS THAN THIS DISTANCE. SEE INTERNATIONAL MECHANICAL CODE FOR EXACT REQUIREMENTS. PARTIAL HVAC DEMO PLAN SCALE: As Shown ENGINEER: RON RICE DWG. BY: S.R. DATE: 1/24/2023 JOB No.: 2245 M1.0 RE X B U R G , I D A H O RE X B U R G S U R G I C A L C E N T E R Ga t e C i t y E N G I N E E R I N G S E R V I C E S 1 2 2 S O U T H M A I N , P O C A T E L L O , I D 8 3 2 0 4 2 0 8 . 2 2 1 . 9 5 0 6 REVISIONS REV DATE DESCRIPTION 1/4"=1'-0" PARTIAL HVAC FLOOR PLAN SCALE: HALL CLEAN UTIL. / STERILE O.R.#1 O.R.#2 BREAK ROOM HALL HALL VEST. VEST. DSSG. T.R. RECOVERY ROOM PREP. SOILED HOLDING RECIEVING STOR. PATIENT EXIT OFFICE CONSULT PREP T.R.REC'P BUSINESS OFFICE WAITING STOR. W.LKR ROOM T.R. FIRE RISER T.R. M.LKR ROOM PREP HALL MECH. CUST. MED GAS ANTH. ROOM SOILED EXISTING RETURN AIR EXISTING RETURN AIR EXISTING RETURN AIR EX I S T I N G R E T U R N A I R EX I S T I N G R E T U R N A I R EX I S T I N G R E T U R N A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR EXISTING SUPPLY AIR EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EX I S T I N G S U P P L Y A I R EXISTING SUPPLY AIR EXISTING SUPPLY AIR EX I S T I N G R E T U R N A I R 1 RTU 2 RTU 10 RTU 8" Ø 8" Ø 8" Ø 8" Ø EXISTING SUPPLY AIR CONNECT NEW SUPPLY DUCT TO EXISTING SUPPLY DUCT CA P / S E A L EX I S T I N G RG-1 RG-1 CD-1 240 CD-1 240 CD-1 240 CD-1 240 CD-EX 100 CD-EX 250 10 X 10 S.A. 20 X 12 R.A. 12 " Ø 12 X 1 2 S . A . T RTU-10 12 " Ø 14 X 12 S.A. 10 X 1 0 S . A . EX EF EX EF NEW RTU-10 LOCATION TO BE A FIELD VERIFIED AND POSITIONED TO MEET MANUFACTURES REQUIRED CLEARANCES 150 CFM 200 CFM DUCT PENETRATIONS THROUGH SIDE WALL AT EXISTING LOCATIONS IN PARAPET. FIELD VERIFY DIMENSIONS / CONFIGURATION BEFORE ORDERING THYBAR FILTER CURBS. PARTIAL HVAC FLOOR PLAN SCALE: As Shown ENGINEER: RON RICE DWG. BY: S.R. DATE: 1/24/2023 JOB No.: 2245 M2.0 RE X B U R G , I D A H O RE X B U R G S U R G I C A L C E N T E R Ga t e C i t y E N G I N E E R I N G S E R V I C E S 1 2 2 S O U T H M A I N , P O C A T E L L O , I D 8 3 2 0 4 2 0 8 . 2 2 1 . 9 5 0 6 REVISIONS REV DATE DESCRIPTION DUCT CONSTRUCTION & HANGER DETAIL DIMENSION OF LONGEST SIDE, INCHES SHEET METAL GAGE (ALL FOUR SIDES) MINIMUM REINFORCING ANGLE SIZE AND MAX LONGITUDINAL SPACING BETWEEN TRANSVERSE JOINTS AND/OR INTERMEDIATE REINFORCING TRANSVERSE REINFORCING, (I) AT JOINTS UP THRU 12 26 NONE REQ'D 26 26 13 - 18 24 NONE REQ'D 24 24 19 - 30 24 1"x1"x1/8" @ 60"-24 DRIVE SLIP HEMMED S SLIP RECOM- MANDED GAGE RECOM- MANDED GAGE (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. METAL FASTENERS - OMARK INSULPING DURO DYNE FASTENERS OR GRIPNAILS. GRIP NAILS SHALL BE INSTALLED BY GRIPNAIL HAMMER GUN OR BY AUTOMATIC FASTENER EQUIPMENT. SELF-TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW HANG DUCTS UP TO 30" WIDTH WITH 1" X 18 GAGE STRAPS @ 10'-0" MAX SPACING STRAPS TO BE TIGHT AGAINST DUCTWORK NO POP RIVETS ALLOWED SHEET METAL DUCT PROVIDE SHEET METAL NOSING OR SLEEVE OVER ANY EXPOSED LINER WHICH FACES THE OPPOSITE DIRECTION AS THE AIRFLOW TOP & BOTTOM SECTION OF LINER SHALL OVERLAP THE SIDES SPACING PER SMACNA (TYP.) DUCT LINER NO MORE THAN 2" FROM EDGE OF LINER ALL ENDS OF LINER TO BE COATED W/ ADHESIVE AND SHALL BE BUTTED FIRMLY TOGETHER NO SCALE VOLUME DAMPER CUT OPENING ACCURATELY FOR SPIN IN (FLARED) FITTING. VOLUME DAMPER. PROVIDE CONCEALED CEILING DAMPER REGULATOR BRANCH DUCT TAKE-OFF DETAIL NO SCALE ALL JOINTS SHALL HAVE A 2" FACING OVERLAYED WITH CIRCUMFERENTIAL JOINTS SEALED WITH 3" WIDE VAPOR BARRIER PRESSURE SENSITIVE FOIL OR VINYL TAPE COMPATIBLE WITH THE FACING. DUCT WRAP 2" THICK, 1.0 lbs. DENSITY DUCT WRAP 2" THICK, 1.0 lbs. DENSITY ROUND DUCT RECTANGULAR DUCT STAPLE LONGITUDINAL JOINTS WITH OUTWARD CLINCHING STAPLES APPROX. 6" ON CENTER AND THEN TAPE THE JOINT WITH 3" WIDE VAPOR BARRIER TAPE. ADHERE INSULATION TO DUCT WITH BONDING ADHESIVE (BENJAMIN FOSTER 85-15 OR I-C-201). FOLDED CORNER DUCT INSULATION DETAIL NO SCALE HANGER STRAPS Ø50" MAX. HANGER STRAP 3 8" BOLT SELF TAPPING CADIUM PLATED HEX HEAD SHEET METAL SCREW. STRAPS TO BE TIGHT AGAINST DUCT ROUND DUCT & STRAP HANGER DETAIL NO SCALE 6" V E R T I C A L GAS LINE CONNECTION DETAIL NO SCALE EQUIPMENT FLEXIBLE GAS CONNECTOR 18" MAX DROP FROM MAIN. SEE PLAN FOR SIZE DRIP LEG SAME AS DROP GROUND JOINT UNION CAPPED PRESSURE TEE GAS PRESSURE REGULATOR 2LB. TO 1/2 OZ. MANUAL SHUT-OFF VALVE SEISMIC PIPING RESTRAINT DETAILS LONGITUDINAL PIPE BRACE TRANSVERSE PIPE BRACING ADD PIPE SLEEVE THAT HAS AN INSIDE DIA. 1/4" LARGER THAN OUTSIDE OF BOLT BOLT TO ANGLE HANGER ROD CLIP OR EQUAL 1 2 MAX DIAGONAL ANGLE PIPE CLAMP HEAVY TYPE OR EQUAL ROD HANGER & VERICAL ANGLE LONGITUDINAL BRACE THREADED BOLT WASHER TO COVER WELD WELDED BEAM ATTACHMENT OR EQUAL PIPE CLAMP HEAVY TYPE OR EQUAL 3/16 TYP. NOTE: SEE STRUCTURAL NOTES FOR DEFERRED SUBMITTAL FOR SEISMIC BRACING. NOTE: CONNECT TO STRUCTURAL SUPPORTING MEMBER TO BE SAME FOR VERTICAL DIAGONAL & LONGITUDINAL ANGLES, NO SCALEROOF TOP UNIT-MOUNTING DETAIL UNIT BASE RAIL 2 X 4 FACTORY WOOD NAILER UNIT HOLD DOWN CLIP (BY MECH, CONTRACTOR) COUNTER FLASHING (BY MECH. CONTRACTOR) CANT STRIP (BY MECH. CONTRACTOR) ROOFING MATERIAL (SEE ARCH DRAWINGS) ROOF INSULATION (VERIFY LOCATION W/ARCH. PLANS) ROOF DECK (SEE ARCH DRAWINGS) RIGID INSULATION (BY MECH. CONTRACTOR) SEE SCHEDULE FOR CONN. TYPE & NO. REQUIRED. ROOF STRUCTURE (SEE STRUCTURAL PLANS ROOF TOP UNIT DUCT FLANGE CONNECTION AT ROOF TOP CURB FLEXIBLE CONN. TO ROOF TOP CURB TRANSITION TO UNIT OPENING FACTORY CURB W/MOUNTING FRAME 1 1/2" RIGID INSULATION FOR SOUND PROOFING (BY MECH. CONTRACTOR) BLOCKING BETWEEN ROOF STRUCTUERE: WOOD - 4X4 BLOCKING W/4X4 HANGER ON EACH END. METAL - 4X4X1/4 ANGLE BLOCKING WELDED TO JOIST TOP CHORDS CONCRETE - NO BLOCKING REQUIRED. SEE DETAIL A DIM. BASED ON ROOFTOP MANUFACTURE FASTEN TO UNIT CURB W/ (2) #12 SCREWS FASTEN TO UNIT BASE RAIL W/ (2) #12 SCREWS UNIT HOLD DOWN CLIP. 14 GAUGE GALV. STEEL ALL DIMENSIONS ARE I.D. (TYP OF 4) NO SCALE & MODEL HVAC ROOFTOP SCHEDULE MANUF. NUMBER NOTESDESCRIPTIONMARKAFUE O.A.TOTAL CFMOUTPUTCOOLING HEATING MOCPVOLTAGEESPHPCFMTONS NOM.SUPPLY FAN MIN. ROOFTOP LENNOX LGT072H4E 6 2400 .8 1.5 30/45 113,000 66,700 240 81%RTU GAS / ELECTRIC INPUT HEATING 150,000 MCA/ FUEL NG ROOFTOPRTU 2 GAS / ELECTRIC 1 CONV. OUTLET, DELTA T-STAT TO MATCH EXISTING ROOFTOP LENNOX LTG036H4E 3 1200 .8 2 19/25 81,000 33,200 200 81%RTU GAS / ELECTRIC 108,000NG10208/3/60 208/3/60 DIFFUSER, GRILLE, & REGISTER SCHEDULE SYMBOL DESCRIPTION NECK NOTESMATERIALPATTERNINSTALLATIONSIZE CD-1 CEILING DIFFUSER STEEL 3 WAY GRILLE SIZE RG-1 STEEL FIXED BLADERETURN GRILLE EER 17 / 12.2 17.8 / 13.3 IEER/ DISCONNECT, HAIL GUARDS, THYBAR FILTER ROOF CURB, DISCONNECT, HAIL GUARDS, THYBAR FILTER ROOF CURB LENNOX LGT072H4E 6 2400 .8 1.5 30/45 113,000 66,700 240 81%150,000NG208/3/60 17 / 12.2 DISCONNECT, HAIL GUARDS, THYBAR FILTER ROOF CURB, CONV. OUTLET, SMOKE DETECTOR CONV. OUTLET, SMOKE DETECTOR STEEL12 X 128" Ø LAY - IN CEILING 14 X 1412" Ø LAY - IN CEILING * FILTRATION BY DYNAMIC AIR QUALITY SOLUTIONS TYPICAL ( DYNAMIC V8 ) * HVAC SCHEDULES AND DETAILS SCALE: As Shown ENGINEER: RON RICE DWG. BY: S.R. DATE: 1/24/2023 JOB No.: 2245 M3.0 RE X B U R G , I D A H O RE X B U R G S U R G I C A L C E N T E R Ga t e C i t y E N G I N E E R I N G S E R V I C E S 1 2 2 S O U T H M A I N , P O C A T E L L O , I D 8 3 2 0 4 2 0 8 . 2 2 1 . 9 5 0 6 REVISIONS REV DATE DESCRIPTION 1-24-2023