Loading...
HomeMy WebLinkAboutPLAN - 22-00683 - Christensen Body Shop - 940 N 2nd E - Monument SignDR A W N B Y : CH K ' D B Y : J. J . C A. C . H . PL O T D A T E : 4/ 2 0 / 2 0 2 1 EN G I N E E R : R A Y M C D O U G A L , P E DE S C R I P T I O N RE V I S I O N D A T E OV E R A L L U T I L I T Y / G R A D I N G SH E E T T I T L E : C-101 PLN# 21-09-013 4/20/2021 10 6 6 N o r t h Y e l l o w s t o n e H w y Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k e n g i n e e r i n g . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C JE F F C H R I S T E N S O N 94 0 N 2 N D E . THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 1 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . DRAINAGE 6''W 3.00' 12 . 5 0 ' 20.00' 50 . 0 0 ' 150.00' 11 0 . 0 0 ' 47.00' 30 . 0 0 ' 30.00' 25.00' 42.21' 8 6 PROPOSED BUILDING 17,995 SQ.FT. 11.00' 51.76' 70.06' 75.00' N. 2 n d E . OIL 77.00 1.9% 8''W 8''W 8''W 8''W 8''W 8''W 4' ' S S ) 4' ' S S ) 4' ' S S ) 4' ' S S ) 6' ' W 6' ' W 6' ' W 6' ' W 6' ' W 6' ' W 6' ' W 6' ' W EO EO EO SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS X-SSMH RIM=4874.86 N INV=4863.61 S INV=4863.54 12''W 12''W 12 ' ' W 12 ' ' W 12''W 12''W 3.00' 20.00' 12 ' ' W 12 ' ' W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12''W 12 ' ' W 12 ' ' W 7.00' 5.00' GRAVEL PARKING/SNOW STORAGE 24.69' OIL 77.00 EO/CONC 76.80 EO/CONC 77.00 77.00 EO/CONCEO/CONC 76.80 3.5% 2.5% 2 .0 % 1 .5% 2 .5% 77.00 OIL 77.00 OIL 76.60 OIL 76.60 OIL 77.00 EO/CONC EO/CONC 76.88 EO/TFW 76.90 EO/TFW 76.85 EO/TFW 76.90 EO/TFW 76.90 EO/TFW 76.90 2.3% 1.5% 4.8% 0.4 0 % 76.15 TBC OIL 74.72 1.0% OIL 74.80 5.5% 74.95 OIL 0.83%0.94%0.94% 1.0% 75.68 OIL F.F.=77.00 7' 30.00' 20.00' 20.00' 20 . 0 0 ' 10.00' 30 . 0 0 ' 10.00' 30 . 0 0 ' 30 . 0 0 ' STORM POND 9' 2657.39' DRAINAGE SWALE 1% 1% 280' OF 12" SD @ 0.22%82' OF 12" SD @ 0.22% OIL 76.16 40.00' 75.61 TBC 6.0' 176.00' 374.00' 176.00' 374.00' 10.00' 31.84' 3 COMPACT 9'x18' 49.98' 27.06' 24.14' 15 9'x20' 9'x20' 3 17 COMPACT 9'x18' 22.74' 9'x20' 25 . 0 0 ' 68.00' 10 . 0 0 ' 3.00' 12 . 5 0 ' 4' 18' EASEMENT INSTRUMENT No. 286455 ZONE = LIGHT INDUSTRIAL FRONT SETBACK= 10' MIN. PROPOSED USE = AUTO REPAIR LOT AREA = 1.511 ACRES GREEN SPACE PROVIDED= 2178 SQ.FT. IMPERVIOUS AREA= SEE TABLE PARKING STALL REQUIREMENT= 1 PER 1,000 SQ.FT. PARKING STALLS PROPOSED= 52 STALLS BUILDING HEIGHT = 20' BUILDING AREA=17,995 SQ.FT. 1. CONTRACTOR TO INSTALL BOLLARDS ON EACH SIDE OF ALL OVERHEAD DOORS TO PROTECT BUILDING OPENINGS. PROPERTY LINE DUMPSTER PAD WITH CHAIN LINK FENCE ENCLOSURE 1 FUTURE DESIGN BY CITY OF REXBURG FUTURE DESIGN BY CITY OF REXBURGFUTURE DESIGN BY CITY OF REXBURG 2 GRASS/LANDSCAPE AREA3 6' THICKENED EDGE SIDEWALK4 6" THICK CONCRETE PAD 5 INSTALL CATCH BASIN 6 ASPHALT 7 1 7 INSTALL 4" SANITARY SEWER SERVICE 7 INSTALL TOUCH READ METER INSIDE BUILDING 8 INSTALL 1.5" WATER SERVICE (INCLUDES ALL APPURTENANCES I.E. VALVES, TEES, BENDS, ETC.) INSTALL 2.5' STANDARD CURB & GUTTER 5' CITY SIDEWALK INSTALL STREET LIGHT INSTALL 6" FIRE LINE (INCLUDES ALL APPURTENANCES I.E. VALVES, TEES, BENDS, ETC.) 48 SA OIL/WATER SEPARATOR (SEE DETAIL SHEET D-1) (OWNER TO PUMP OUT AS REQUIRED BY MANUFACTURER) 10 4 4 11 5" THICK CONCRETE PAD 5 5 5 TIE ONTO EXISTING WATERMAIN TIE ONTO EXISTING SANITARY SEWER MAIN INSTALL STANDARD SSMH9 9 12 8 13 10 16 3 13 12 14 14 14 2 599.50' 50.00' W 1/4 COR OF SECTION 17 T.6N., R.40E. B.M. SW COR OF SECTION 17 T.6N., R.40E. B.M. SECTION LINE - BASIS OF BEARING 2057.89' 15 15 11 16 INSTALL 8"x6" TEE & THRUST BLOCK AND STUB WATER 10' NORTH INSTALL 12"x8" TEE & THRUST BLOCK INSTALL CB #1 GRATE=74.95 12" INV OUT=71.89 INSTALL CB #2 GRATE=74.80 12" INV IN=71.26 12" INV OUT=71.16 LANDSCAPE POND MEETING CITY STANDARDS 12" INV=70.95 INSTALL CLEAN OUT INSTALL CURB STOP EXISTING 12" WATERMAIN CONTRACTOR TO VERIFY INSTALL WATER VALVE SECTION LINE INSTALL CLEAN OUT 17 17 INSTALL RIP/RAP-SEE TABLE NOTES INSTALL 40' WIDE CURB CUT CONCRETE APPROACH PROPERTY LINE INSTALL WATER VALVE MANIFOLD PIPEMANIFOLD PIPEMANIFOLD PIPEMANIFOLD PIPE TWO-ROWS OFTWO-ROWS OFTWO-ROWS OFTWO-ROWS OF STORMTECH SC-740STORMTECH SC-740STORMTECH SC-740STORMTECH SC-740.... 20 STORMTECHS PER20 STORMTECHS PER20 STORMTECHS PER20 STORMTECHS PER ROW.ROW.ROW.ROW. OPTIONALOPTIONALOPTIONALOPTIONAL INSPECTIONINSPECTIONINSPECTIONINSPECTION PORTSPORTSPORTSPORTS BUILDER TO DETERMINEBUILDER TO DETERMINEBUILDER TO DETERMINEBUILDER TO DETERMINE ELEVATION OF INLET.ELEVATION OF INLET.ELEVATION OF INLET.ELEVATION OF INLET. ADD BACKFILL TO DESIREADD BACKFILL TO DESIREADD BACKFILL TO DESIREADD BACKFILL TO DESIRE GRADE. GRADE. GRADE. GRADE. ORIGINAL CIVILORIGINAL CIVILORIGINAL CIVILORIGINAL CIVIL DESIGN BY EAGLEDESIGN BY EAGLEDESIGN BY EAGLEDESIGN BY EAGLE ROCK ENGINEERINGROCK ENGINEERINGROCK ENGINEERINGROCK ENGINEERING 1111 R-102R-102R-102R-102 1111 R-102R-102R-102R-102 GENERAL NOTE:GENERAL NOTE:GENERAL NOTE:GENERAL NOTE: 1. INSTALL PER MANUFACTURER SPECIFICATIONS 2. THE LOCATIONS, SIZES, AND TYPES OF EXISTING UTILITIES ARE SHOWN AS APPROXIMATE REPRESENTATION ONLY. THE OWNER OR ITS REPRESENTATIVES HAVE NOT INDEPENDENTLY VERIFIED THIS INFORMATION AS SHOWN ON THE PLANS. THE UTILITY INFORMATION SHOWN DOES NOT GUARANTEE THE ACTUAL EXISTENCE, SERVICEABILITY, OR OTHER DATA CONCERNING THE UTILITIES, NOR DOES IT GUARANTEE AGAINST THE POSSIBILITY THAT ADDITIONAL UTILITIES MAY BE PRESENT THAT ARE NOT SHOWN ON THE PLANS. PRIOR TO ORDERING MATERIALS AND BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL VERIFY AND DETERMINE THE EXACT LOCATIONS, SIZES, AND ELEVATIONS OF THE POINTS OF CONNECTIONS TO EXISTING UTILITIES AND, SHALL CONFIRM THAT THERE ARE NO INTERFERENCES WITH EXISTING UTILITIES AND THE PROPOSED UTILITY ROUTES, INCLUDING ROUTES WITHIN THE PUBLIC RIGHTS OF WAY. 3. WHERE AN EXISTING UTILITY IS FOUND TO CONFLICT WITH THE PROPOSED WORK, OR EXISTING CONDITIONS DIFFER FROM THOSE SHOWN SUCH THAT THE WORK CANNOT BE COMPLETED AS INTENDED, THE LOCATION, ELEVATION, AND SIZE OF THE UTILITY SHALL BE ACCURATELY DETERMINED WITHOUT DELAY BY THE CONTRACTOR, AND THE INFORMATION FURNISHED IN WRITING TO THE OWNERS REPRESENTATIVE FOR THE RESOLUTION OF THE CONFLICT AND CONTRACTORS FAILURE TO NOTIFY PRIOR TO PERFORMING ADDITIONAL WORK RELEASES OWNER FROM OBLIGATION FOR ADDITIONAL PAYMENTS WHICH OTHERWISE MAY BE WARRANTED TO RESOLVE THE CONFLICT. DR A W N B Y : CH K ' D B Y : J. J . C A. C . H . PL O T D A T E : 4/ 2 0 / 2 0 2 1 EN G I N E E R : R A Y M C D O U G A L , P E DE S C R I P T I O N RE V I S I O N D A T E ST O R M W A T E R D E T A I L S SH E E T T I T L E : R-101 PLN# 21-09-013 4/20/2021 10 6 6 N o r t h Y e l l o w s t o n e H w y Re x b u r g , I D 8 3 4 4 0 ww w . s o u t h f o r k e n g i n e e r i n g . c o m 20 8 - 8 5 2 - 6 2 3 6 So u t h F o r k D e s i g n G r o u p , L L C JE F F C H R I S T E N S O N 94 0 N 2 N D E . THESE PLANS ARE STAMPED/ENGINEERED FOR THE LOCATION SPECIFIED. IF LOCATION CHANGES REENGINEERING IS REQUIRED. Co p y r i g h t 2 0 2 1 | S o u t h f o r k E n g i n e e r i n g | A l l R i g h t s R e s e r v e d . 6" MIN.6" MIN.6" MIN.6" MIN.12" MIN.12" MIN.12" MIN.12" MIN.51"51"51"51" 6" MIN.6" MIN.6" MIN.6" MIN. 18" MIN.18" MIN.18" MIN.18" MIN.96" MAX.96" MAX.96" MAX.96" MAX. 6" DEPTH MIN.6" DEPTH MIN.6" DEPTH MIN.6" DEPTH MIN. PAVEMENTPAVEMENTPAVEMENTPAVEMENT GRANULAR WELL GRADEDGRANULAR WELL GRADEDGRANULAR WELL GRADEDGRANULAR WELL GRADED SOIL/AGGREGATE MIXTURES,SOIL/AGGREGATE MIXTURES,SOIL/AGGREGATE MIXTURES,SOIL/AGGREGATE MIXTURES, <35% FINES. COMPACT IN 6"<35% FINES. COMPACT IN 6"<35% FINES. COMPACT IN 6"<35% FINES. COMPACT IN 6" LIFTS TO 95& STANDARDLIFTS TO 95& STANDARDLIFTS TO 95& STANDARDLIFTS TO 95& STANDARD PROCTOR DENSITY. PROCTOR DENSITY. PROCTOR DENSITY. PROCTOR DENSITY. SEESEESEESEE MANUFACTURERS TABLE OFMANUFACTURERS TABLE OFMANUFACTURERS TABLE OFMANUFACTURERS TABLE OF ACCEPTABLE FILL MATERIALSACCEPTABLE FILL MATERIALSACCEPTABLE FILL MATERIALSACCEPTABLE FILL MATERIALS CHAMBERS SHALL BE DESIGNED INCHAMBERS SHALL BE DESIGNED INCHAMBERS SHALL BE DESIGNED INCHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787ACCORDANCE WITH ASTM F2787ACCORDANCE WITH ASTM F2787ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL"STANDARD PRACTICE FOR STRUCTURAL"STANDARD PRACTICE FOR STRUCTURAL"STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTICDESIGN OF THERMOPLASTICDESIGN OF THERMOPLASTICDESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATERCORRUGATED WALL STORMWATERCORRUGATED WALL STORMWATERCORRUGATED WALL STORMWATER COLLECTION CHAMBERS"COLLECTION CHAMBERS"COLLECTION CHAMBERS"COLLECTION CHAMBERS" CHAMBERS SHALL BE MANUFACTURED FROMCHAMBERS SHALL BE MANUFACTURED FROMCHAMBERS SHALL BE MANUFACTURED FROMCHAMBERS SHALL BE MANUFACTURED FROM VIRGIN POLYPROPYLENE OR POLYETHYLENEVIRGIN POLYPROPYLENE OR POLYETHYLENEVIRGIN POLYPROPYLENE OR POLYETHYLENEVIRGIN POLYPROPYLENE OR POLYETHYLENE RESINS TESTING USING ASTM STANDARDS.RESINS TESTING USING ASTM STANDARDS.RESINS TESTING USING ASTM STANDARDS.RESINS TESTING USING ASTM STANDARDS. NOMINAL 3/4"-2"NOMINAL 3/4"-2"NOMINAL 3/4"-2"NOMINAL 3/4"-2" CLEAN, CRUSHED, ANGULAR STONECLEAN, CRUSHED, ANGULAR STONECLEAN, CRUSHED, ANGULAR STONECLEAN, CRUSHED, ANGULAR STONE ADS 601-WOVEN GEOTEXTILEADS 601-WOVEN GEOTEXTILEADS 601-WOVEN GEOTEXTILEADS 601-WOVEN GEOTEXTILE (OR EQUAL) ALL AROUND CLEAN,(OR EQUAL) ALL AROUND CLEAN,(OR EQUAL) ALL AROUND CLEAN,(OR EQUAL) ALL AROUND CLEAN, CRUSHED, ANGULAR STONECRUSHED, ANGULAR STONECRUSHED, ANGULAR STONECRUSHED, ANGULAR STONE ADS 601-WOVEN GEOTEXTILEADS 601-WOVEN GEOTEXTILEADS 601-WOVEN GEOTEXTILEADS 601-WOVEN GEOTEXTILE (OR EQUAL) ALL AROUND CLEAN,(OR EQUAL) ALL AROUND CLEAN,(OR EQUAL) ALL AROUND CLEAN,(OR EQUAL) ALL AROUND CLEAN, CRUSHED, ANGULAR STONECRUSHED, ANGULAR STONECRUSHED, ANGULAR STONECRUSHED, ANGULAR STONE ADS 601-WOVEN GEOTEXTILEADS 601-WOVEN GEOTEXTILEADS 601-WOVEN GEOTEXTILEADS 601-WOVEN GEOTEXTILE (OR EQUAL) ALL AROUND CLEAN,(OR EQUAL) ALL AROUND CLEAN,(OR EQUAL) ALL AROUND CLEAN,(OR EQUAL) ALL AROUND CLEAN, CRUSHED, ANGULAR STONECRUSHED, ANGULAR STONECRUSHED, ANGULAR STONECRUSHED, ANGULAR STONE SC-740 END CAPSC-740 END CAPSC-740 END CAPSC-740 END CAP FOR UNPAVED INSTALLATIONFOR UNPAVED INSTALLATIONFOR UNPAVED INSTALLATIONFOR UNPAVED INSTALLATION WHERE RUTTING FROM VEHICLES MAYWHERE RUTTING FROM VEHICLES MAYWHERE RUTTING FROM VEHICLES MAYWHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 24" MIN.OCCUR, INCREASE COVER TO 24" MIN.OCCUR, INCREASE COVER TO 24" MIN.OCCUR, INCREASE COVER TO 24" MIN. INSPECTION & MAINTENANCEINSPECTION & MAINTENANCEINSPECTION & MAINTENANCEINSPECTION & MAINTENANCE STEP 1) INSPECT ISOLATOR ROW PLUS FOR SEDIMENT A. INSPECTION PORTS (IF PRESENT) A.1. REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN A.2. REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED A.3. USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOG A.4. LOWER A CAMERA INTO ISOLATOR ROW PLUS FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL) A.5. IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3. B. ALL ISOLATOR PLUS ROWS B.1. REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW PLUS B.2. USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW PLUS THROUGH OUTLET PIPE i) MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY ii)FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE B.3. IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3. STEP 2) CLEAN OUT ISOLATOR ROW PLUS USING THE JETVAC PROCESS A. A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERRED B. APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN C. VACUUM STRUCTURE SUMP AS REQUIRED STEP 3)REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS. STEP 4) NOTESNOTESNOTESNOTES 1. INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS. 2. CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY. SC-740 END CAP OPTIONAL INSPECTION PORTSC-740 CHAMBER ONE LAYER OF ADSPLUS125 WOVEN GEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS 5' MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS 24" (600 mm) HDPE ACCESS PIPE REQUIRED USE FACTORY PRE-FABRICATED END CAP WITH FLAMP PART #: SC740EPE24BR NOTE: INSPECTION PORTS MAY BE CONNECTED THROUGH ANY CHAMBER CORRUGATION CREST. STORMTECH CHAMBER CONCRETE COLLAR PAVEMENT CONCRETE SLAB 6" MIN THICKNESS 4" PVC INSPECTION PORT DETAIL4" PVC INSPECTION PORT DETAIL4" PVC INSPECTION PORT DETAIL4" PVC INSPECTION PORT DETAIL (SC SERIES CHAMBER)(SC SERIES CHAMBER)(SC SERIES CHAMBER)(SC SERIES CHAMBER) 8" NYLOPLAST INSPECTION PORT BODY (PART# 2708AG4IPKIT) ORTRAFFIC RATED BOX W/SOLIDLOCKING COVER CONCRETE COLLAR NOT REQUIRED FOR UNPAVED APPLICATIONS 4" SDR 35 PIPE 4" INSERTA TEE TO BE CENTERED ON CORRUGATION CREST INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM. SU M P D E P T H SU M P D E P T H SU M P D E P T H SU M P D E P T H (2 4 " M I N . R E C O M M E N D E D ) (2 4 " M I N . R E C O M M E N D E D ) (2 4 " M I N . R E C O M M E N D E D ) (2 4 " M I N . R E C O M M E N D E D ) 12" MIN. WIDTH12" MIN. WIDTH12" MIN. WIDTH12" MIN. WIDTH COVER ENTIRE ISOLATOR ROW PLUS WITH ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE 8' MIN. WIDE STORMTECH HIGHLY RECCOMENDS FLEXSTORM INSERTS IN ANY UPSTREAM STRUCTURES WITH OPEN GRATES ELEVATED BYPASS MANIFOLD CATCH BASIN OR MANHOLE 90.7" ACTUAL LENGTH90.7" ACTUAL LENGTH90.7" ACTUAL LENGTH90.7" ACTUAL LENGTH 85.4" INSTALLED85.4" INSTALLED85.4" INSTALLED85.4" INSTALLED 51"51"51"51" 30 " 30 " 30 " 30 " OVERLAPOVERLAPOVERLAPOVERLAP NEXT CHAMBER HERE NEXT CHAMBER HERE NEXT CHAMBER HERE NEXT CHAMBER HERE (OVER "SMALL" CORRUGATION)(OVER "SMALL" CORRUGATION)(OVER "SMALL" CORRUGATION)(OVER "SMALL" CORRUGATION) START END ACCEPTS 4" SCH 40 PIPEACCEPTS 4" SCH 40 PIPEACCEPTS 4" SCH 40 PIPEACCEPTS 4" SCH 40 PIPE FOR INSPECTION PORTFOR INSPECTION PORTFOR INSPECTION PORTFOR INSPECTION PORT NOMINAL CHAMBER SPECIFICATIONSNOMINAL CHAMBER SPECIFICATIONSNOMINAL CHAMBER SPECIFICATIONSNOMINAL CHAMBER SPECIFICATIONS SIZE (W x H x INSTALLED LENGTH - 51.0" x 30.0" x 85.4"SIZE (W x H x INSTALLED LENGTH - 51.0" x 30.0" x 85.4"SIZE (W x H x INSTALLED LENGTH - 51.0" x 30.0" x 85.4"SIZE (W x H x INSTALLED LENGTH - 51.0" x 30.0" x 85.4" CHAMBER STORAGE - 45.9 CUBIC FEETCHAMBER STORAGE - 45.9 CUBIC FEETCHAMBER STORAGE - 45.9 CUBIC FEETCHAMBER STORAGE - 45.9 CUBIC FEET MINIMUM INSTALLED STORAGE - 74.9 CUBIC FEETMINIMUM INSTALLED STORAGE - 74.9 CUBIC FEETMINIMUM INSTALLED STORAGE - 74.9 CUBIC FEETMINIMUM INSTALLED STORAGE - 74.9 CUBIC FEET WEIGHT - 75 LBS.WEIGHT - 75 LBS.WEIGHT - 75 LBS.WEIGHT - 75 LBS. A B STORMTECH CHAMBERS FOUNDATION STONE BENEATH CHAMBERS B A FO U N D A T I O N S T O N E FO U N D A T I O N S T O N E FO U N D A T I O N S T O N E FO U N D A T I O N S T O N E BE N E A T H C H A M B E R S BE N E A T H C H A M B E R S BE N E A T H C H A M B E R S BE N E A T H C H A M B E R S DUAL WALLDUAL WALLDUAL WALLDUAL WALL PERFORATEDPERFORATEDPERFORATEDPERFORATED HDPEHDPEHDPEHDPE UNDERDRAINUNDERDRAINUNDERDRAINUNDERDRAIN DUAL WALLDUAL WALLDUAL WALLDUAL WALL PERFORATEDPERFORATEDPERFORATEDPERFORATED HDPEHDPEHDPEHDPE UNDERDRAINUNDERDRAINUNDERDRAINUNDERDRAIN OUTLET MANIFOLDOUTLET MANIFOLDOUTLET MANIFOLDOUTLET MANIFOLD STORMTECHSTORMTECHSTORMTECHSTORMTECH END CAPEND CAPEND CAPEND CAP STORMTECHSTORMTECHSTORMTECHSTORMTECH CHAMBERCHAMBERCHAMBERCHAMBER ADS GEOSYNTHETICS 601TADS GEOSYNTHETICS 601TADS GEOSYNTHETICS 601TADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILENON-WOVEN GEOTEXTILENON-WOVEN GEOTEXTILENON-WOVEN GEOTEXTILE STORMTECHSTORMTECHSTORMTECHSTORMTECH CHAMBERCHAMBERCHAMBERCHAMBER ADS GEOSYNTHETICS 601TADS GEOSYNTHETICS 601TADS GEOSYNTHETICS 601TADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILENON-WOVEN GEOTEXTILENON-WOVEN GEOTEXTILENON-WOVEN GEOTEXTILE 6" 6" 6" 6" TYTYTYTYP FOR SC-740, DC-780,P FOR SC-740, DC-780,P FOR SC-740, DC-780,P FOR SC-740, DC-780, MC-3500 & MC-4500MC-3500 & MC-4500MC-3500 & MC-4500MC-3500 & MC-4500 SYSTEMSSYSTEMSSYSTEMSSYSTEMS SECTION A-ASECTION A-ASECTION A-ASECTION A-A SECTION SECTION SECTION SECTION B-BB-BB-BB-B 1 STORMTECH CROSS SECTIONSTORMTECH CROSS SECTIONSTORMTECH CROSS SECTIONSTORMTECH CROSS SECTION NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE 2 ISOLATION ROW PLUS DETAILISOLATION ROW PLUS DETAILISOLATION ROW PLUS DETAILISOLATION ROW PLUS DETAIL NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE 3 STORMTECH CHAMBERSTORMTECH CHAMBERSTORMTECH CHAMBERSTORMTECH CHAMBER NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE 4 UNDERDRAIN DETAILUNDERDRAIN DETAILUNDERDRAIN DETAILUNDERDRAIN DETAIL NOT TO NOT TO NOT TO NOT TO SCALESCALESCALESCALE