HomeMy WebLinkAboutREDLINED PLANS - 22-00282 - Teton River Lofts - 24 Units - Bldg 1Author Name Author Email Author Phone No.:
Tawnya Grover Tawnya.Grover@rexburg.org 208-372-2167
Alex Owens Alex.Owens@rexburg.org 208-372-2330
Cody Jones Cody.Jones@rexburg.org 208-372-2173
Don Allen Don.Allen@rexburg.org 208-372-2174
Description : Teton River Lofts Community Housing PH1 - 24 Units - Bldg 1
Address : 311 E Lorene St
Application Type :
Document Filename : PLANS - 22-00282 - Teton River Lofts Community Housing PH1 - 24 Units - Bldg 1.pdf Array
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Revisions Required
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
T1.1 Free text Cody Jones : Building Open 1 As per section 1107 one unit needs to be an accessible unit,
2% need to be Type A units and the remainder Type B.
CR1.1 Free text Cody Jones : Building Open 2 Damp proofing and waterproofing to comply with section
1805.
Site grading needs to meet the requirements of section 1804.4
CR1.2 Comment Cody Jones : Building Open 3 Penetrations comply with IBC Section 714 for rated assemblies
CR1.2 Free text Cody Jones : Building Open 3 Exit access travel distance maximum of 250'.
CR1.2 Comment Cody Jones : Building Open 3 Dwelling Unit Sound Transmission comply with IBC Section
1207
CR1.3 Comment Cody Jones : Building Open 4 Concealed spaces are fireblocked/draftstopped per Section
718
A1.1 Free text Cody Jones : Building Open 9 Panic hardware shall be installed as per IBC section 1010.1.10
on required doors.
A9.1 Free text Cody Jones : Building Open 29 Riser height 4"-7"as per section 1011.5.2.
# 22-00282
New Multi-Family Residence
Penetrations comply with IBC Section 714 for rated assemblies
Report Date: 05.03.2022
Approval of plans does not constitute approval of variance from code
Page 1 of 2
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
A10.1 Free text Cody Jones : Building Open 30 All glass and glazing to meet requirements of Chapter 24.
S1.0 Free text Cody Jones : Building Open 38 City of Rexburg
S1.1 Free text Cody Jones : Building Open 39 Special inspector needs to be identified.
S2.0 Comment Cody Jones : Building Open 42 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12"
Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6"
S2.3 Free text Cody Jones : Building Open 45 Need to have engineered truss plans that are also approved
by design professional.
E2.0 Callout Alex Owens : Electrical Open 66 For verification; as per 2017 NEC main breaker panels are not
required in each room. Please verify if desired.
E2.0 Callout Alex Owens : Electrical Open 66 For verification; 2017 NEC does not require dryer and range
GFCI protection, Idaho exemptions do not require GFCI
protection.
E2.0 Callout Alex Owens : Electrical Open 66 For verification: As per Idaho exemption, AFCI protection
required for bedroom circuits only.
E2.0 Free text Alex Owens : Electrical Open 66 All outlet boxes in walls that are located in walls joining two
separate units shall be placed in such a manner as to maintain
fire ratings for that specific box.
E3.0 Callout Alex Owens : Electrical Open 67 For verification: Wire sizes exceed code requirements in
250.66. Will inspect as per these requirements if desired.
Report Date: 05.03.2022
Approval of plans does not constitute approval of variance from code
Page 2 of 2
Powered by TCPDF (www.tcpdf.org)
THE PROPOSED PROJECT CONSISTS OF A MULTI-FAMILY RESIDENTIAL STRUCTURE INCLUDING 24 DWELLING UNITS ON THREE FLOORS. THE
GROUND FLOOR IS APPROXIMATELY 7,184 S.F. AND THE TWO UPPER TWO FLOORS ARE 7,011 S.F. EACH. THE PROPOSED BUILDING IS
INTENDED TO BE CONSTRUCTED TEN TIMES ON THE SITE AS A PROTOTYPE. THE BUILDING WILL CONSTRUCTED USING CONVENTIONAL WOOD
FRAMED CONSTRUCTION. THE STRUCTURE WILL BE FIRE SPRINKLERED WITH REQUIRED FIRE RESISTANCE RATED PARTITIONS. SITE
IMPROVEMENTS INCLUDE SIDEWALKS, PARKING AREAS, LANDSCAPING AND RELATED WORK.
OCCUPANCY: R-2
NO. OF STORIES: 3
TYPE OF CONSTRUCTION: V-B
BUILDING HEIGHT:
GROSS AREA:
OWNER:
TETON RIVER LOFTS, LLC
PROJECT ADDRESS:
BUILDING CODES APPLICABLE:
2018 INTERNATIONAL BUILDING CODE
2018 ENERGY CONSERVATION CODE
2018 INTERNATIONAL MECHANICAL CODE
2017 NATIONAL ELECTRIC CODE
2018 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL FUEL GAS CODE
2018 INTERNATIONAL PLUMBING CODE
OWNER:
TETON RIVER LOFTS, LLC
ARCHITECT:
GPC ARCHITECTS
18 N. MAIN ST, SUITE 200
PO BOX 330
DRIGGS, ID 83422
PHONE: 208.354.8036
EMAIL: gchadwick@gpcarch.com
CONTACT: GARETT CHADWICK, AIA, LEED AP BD&C
CONSTRUCTION MANAGER - GENERAL CONTRACTOR:
VENTURE BUILDERS, LLC
280 E LORENE ST. UNIT 9102
REXBURG, ID 83440
PHONE: 208.313.0980
EMAIL: scott@venturebuilders-id.com
CIVIL ENGINEER:
STRUCTURAL ENGINEER:
FROST STRUCTURAL ENGINEERING
1020 LINCOLN ROAD
IDAHO FALLS, ID 83401
PHONE: 208.227.8404
EMAIL: contact@frost-structural.com
NORTH
NOTE: NOT ALL SYMBOLS ARE USED
ARCHITECTURAL
CR1.1 CODE REVIEW
CR1.2 CODE REVIEW 1ST FLOOR PLAN
CR1.3 CODE REVIEW 2ND FLOOR PLAN
CR1.4 CODE REVIEW SECTIONS
CR1.5 CODE REVIEW TYPE A UNIT FLOOR PLANS
CR1.6 ICC A117.1-2017 FIGURES
CR1.7 COMCHECK
A1.1 1ST FLOOR PLAN
A1.2 2ND FLOOR PLAN
A1.3 3RD FLOOR PLAN
A1.4 1ST FLOOR UNIT PLANS
A1.5 2ND & 3RD FLOOR UNIT PLANS
A2.1 AREA PLANS
A2.2 BUILDING DETAILS
A3.1 EXTERIOR ELEVATIONS
A3.2 EXTERIOR ELEVATIONS
A3.3 EXTERIOR PERSPECTIVES
A4.1 ROOF PLAN
A4.2 ROOF DETAILS
A5.1 BUILDING SECTIONS
A5.2 BUILDING SECTIONS
A5.3 BUILDING SECTIONS
A5.4 BUILDING SECTIONS
A5.5 BUILDING SECTIONS
A6.1 WALL SECTIONS
A6.2 WALL SECTIONS
A8.1 INTERIOR ELEVATIONS
A9.1 STAIR PLANS AND SECTIONS
A10.1 DOOR & WINDOW SCHEDULES
A10.2 WINDOW AND DOOR DETAILS
A11.1 1ST FLOOR REFLECTED CEILING PLAN
A11.2 2ND FLOOR REFLECTED CEILING PLAN
A11.3 3RD FLOOR REFLECTED CEILING PLAN
A11.4 1ST FLOOR UNIT REFLECTED CEILING PLANS
A11.5 2ND & 3RD FLOOR UNIT REFLECTED CEILING
PLANS
A12.1 PRODUCT SPECIFICATIONS
SHEET NUMBER SHEET NAME
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
4
2
P
M
T1.1
TITLE SHEET
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
TITLE
T1.1 TITLE SHEET
MECHANICAL ENGINEER:
ENGINEERED SYSTEMS ASSOCIATES, INC.
1355 EAST CENTER ST.
POCATELLO, ID 83201
PHONE: 208.233.0501
EMAIL: esa@engsystems.com
ELECTRICAL ENGINEER:
PAYNE ENGINEERING, INC.
1823 EAST CENTER ST.
POCATELLO, ID 83201
PHONE: 208.232.4439
EMAIL: admin@payneengineeringinc.com
ABV Above
A/C Air Conditioning
ACT Acoustical Ceiling Tile
ADJ Adjustable, Adjacent
A.F.F.Above Finish Floor
A.I.B.Air Infiltration Barrier
ALT Alternate
ALUM Aluminum
APPROX Approximate
ARCH Architectural/Architect
BD Board
BLDG Building
BLK Block
BLKG Blocking
BLW Below
BM Beam
B.M.Bench Mark
BN Bullnose
B.O.F. Bottom of Footing
B.O.M.Bottom of Masonry
BRG Bearing
BTM Bottom
BTWN Between
B.U.Built-up
CAB Cabinet
CEM Cement
C.I.Cast Iron
C.J.Control Joint
CLG Ceiling
CLO Closet
C.M.Construction Manager
C.M.U. Concrete Masonry Unit
C.O. Clean out
COL Column
CONC Concrete
CONST.JT.Construction Joint
CONT Continuous
CONTR Contractor
COORD Coordinate
CORR Corridor
CPT Carpet
C.T. Ceramic Tile
CTR Center
C.W. Cold Water
DBL Double
DET Detail
D.F. Drinking Fountain
DIA Diameter
DIM Dimension
DISP Dispenser/Disposal
DN Down
D.P.Dampproofing
DR Door
DRF Draftstopping
D.S.Downspout
DWG Drawing
EA Each
E.C.Electrical Contractor
E.E. Each End
E.I.F.S.Exterior Insulation and
Finish System
E.J. Expansion Joint
E.J.C. Expansion Joint Cover
EL Elevation
ELEC Electrical/Electric
E/O Equipment by Owner
E.P.D.M.Ethylene Propylene
Diene Monomer
E.P.S. Expanded Polystyrene
EQ Equal
EQUIP Equipment
E.W.C. Electric Water Cooler
E.W.S. Exterior Wall System
EXIST or
(e)Existing
EXP Expansion
EXT Exterior
F.D.Floor Drain
FDN Foundation
F.E. Fire Extinguisher
FIN Finish
FLR/FL Floor
F.N.D. Feminine Napkin Disposal
F.N.V.Feminine Napkin Vendor
F.O.B. Face of Brick
F.O.F. Face of Framing
F.O.S. Face of Stud
FR Frame
FT Feet/Foot
FTG Footing
FURR Furring
GA Gauge
GALV Galvanized
G.B. Grab Bar
GEN General
G.I. Galvanized Iron
GL Glass
G.W.B. Gypsum Wallboard
H.B. Hose Bibb
H/C Handicapped
H.C. Hollow Core
H.D.Heavy Duty
HDNR Hardener
HDW Hardware
H.M. Hollow Metal
HORZ Horizontal
HT Height
H.W. Hot Water
ICF Insulated Concrete Form
I.D. Inside Diameter
IN Inch/Inches
INCL Including
INFO Information
INSUL Insulation
INT Interior
INV Invert
JAN Janitor
JT Joint
LKRS Lockers
LOC Location
MASRY Masonry Block
MAT/MAT'L Material
MAX Maximum
MECH Mechanical
MEMB.W.P.Membrane
Waterproofing
MEZZ. Mezzanine
MFR/MFG Manufacturer/
Manufacturing
M.H.Manhole
Min Minimum
MISC Miscellaneous
M.L.P.Metal Liner Panel
M.O.Masonry Opening
M.T.Metal Threshold
MTL Metal
M.T.P.Metal Toilet Partition
(N)New
NEC'Y Necessary
N.I.C.Not in Contract
NOM Nominal
N.T.S.Not to Scale
O.A.F.Overall Frame
O.C.On Center
O.D.Outside Diameter
O.H.Overhead
OPNG Opening
OPP Opposite
OPP.H.Opposite Hand
ORIG Original
O.F.C.I.Owner Furnished
Contractor Installed
O.F.O.I.Owner Furnished
Owner Installed
PL or Plate
P.Lam Plastic Laminate
PLAS Plastic
PLYWD Plywood
PREFAB Prefabricated
PT Paint
P.T.D.Paper Towel Dispenser
P.T.W.Pressure Treated Wood
PTN Partition
QT Quarry Tile
(R)Remove
RAD Radius
R.D.Roof Drain
RECMND Recommendation
REF Reference/Refrigerator
REINF Reinforce/Reinforcing
REQ'D Required
RET Retain/Retained
REV Revisions
R.F.Resilient Flooring
RM Room
R.O.Rough Opening
RTG Rating
S.C.Solid Core
SCHED Schedule
S.C.W.Solid Core Wood
S.D.Soap Dispenser
SECT Section
S.F.Square Feet
S.F.C.Special Floor Coating
S.G.T.Structural Glazed Tile
SHWR Shower
SHT Sheet
SHTG Sheathing
SIM Similar
SPECS Specifications
SQ Square
S.S.Stainless Steel
STD Standard
STL Steel
STOR Storage
STRUCT Structural
SUSP Suspended
S.W.C.Special Wall Coating
TEL Telephone
TEMP Tempered
T.O.BM.Top of Beam
T.O.C.Top of Concrete
T.O.F.Top of Footing
TOIL Toilet
T.O.J.Top of Joist
T.O.M.Top of Masonry
T.O.S.Top of Steel
T.P.D.Toilet Paper Dispenser
TRANS.
FG. PNL.
Translucent Fiberglass
Panel
TRTD Treated
TYP Typical
U.G.Underground
U.L.Underwriters Laboratory
UNEXC Unexcavated
UNFIN Unfinished
U.N.O.Unless Noted Otherwise
U.S.Underside
(V)Verify
V.C.T.Vinyl Composition TIle
VENT Ventilation/Ventilator
VERT Vertical
V.I.F.Verify in Field
VISQ.V.B.Visqueen Vapor Barrier
V.S.G.Vinyl Sheet Goods
V.T.R.Vent Thru Roof
VWC Vinyl Wallcovering
W/With
W.C.Water Closet
WD Wood
WDO Window
W/O Without
W.P.Waterproof
XX.X
X
X
X
X
X
XX.X
X
XX.X
X
XX.X
XX.X
XXX
X
XXX
XX
X
X'-X"CX
XXX
KEY TO SYMBOLSSTANDARD ABBREVIATIONS
VICINITY MAP
BUILDING DATA
INDICATES CENTER LINE
EXTERIOR ELEVATION NUMBER
DETAIL NUMBER
BUILDING SECTION LETTER
WALL SECTION NUMBER
SHEET DRAWN ON
WALL TYPE
LETTER
TOILET ACCESSORY
BORROWED LITE TAG
CEILING TYPE TAG
EXTERIOR WINDOW LETTER
& BORROWED LITE TAG
ROOM NUMBER
KEYED NOTE
NUMBER
INTERIOR & EXTERIOR
DOOR OR GATE NUMBER
SHEET DRAWN ON
SHEET DRAWN ON
SHEET DRAWN ON
INTERIOR ELEVATION NUMBER
SHEET DRAWN ON
INDEX TO DRAWINGS
RCP Reflected Ceiling Plan
PROJECT TEAM
X
PROJECT SUMMARY
CONSTRUCTION DOCUMENTS
ACCESS. Accessory
XXXXXX.XX
BOARD INSULATION & E.I.F.S.
IN PLAN & SECTION
DRYWALL OR PLASTER
IN PLAN & SECTION
PLYWOOD
IN PLAN & SECTION
ACOUSTIC TILE
IN SECTION
METAL
IN PLAN & SECTION
BRICK IN
PLAN & SECTION
CONCRETE BLOCK IN
PLAN & SECTION
CONCRETE IN
PLAN & SECTION
GRAVEL IN
PLAN & SECTION
EARTH IN SECTION
BATT INSULATION IN SECTION
WALL
IN PLAN & SECTION
FINISHED WOOD
IN SECTION
4/
1
9
/
2
0
2
2
1
:
5
1
:
4
2
P
M
TETON RIVER LOFTS
REXBURG, IDAHO
THIS IMAGE IS CONCEPTUAL AND MAY NOT COINCIDE WITH THE CONSTRUCTION DOCUMENTS
MECHANICAL
M1.1 1ST LEVEL MECHANICAL PLAN
M1.2 2ND LEVEL MECHANICAL PLAN
M1.3 3RD LEVEL MECHANICAL PLAN
M2.0 LARGE SCALE MECH. PLANS
M2.1 LARGE SCALE MECH. PLANS
M3.0 MECHANICAL SCHEDULES & DETAILS
STRUCTURAL
S1.0 GENERAL STRUCTURAL NOTES
S1.1 SPECIAL INSPECTIONS
S1.2 TYPICAL DETAILS
S1.3 TYPICAL DETAILS
S2.0 FOUNDATION PLAN
S2.1 SECOND FLOOR FRAMING PLAN
S2.2 THIRD FLOOR FRAMING PLAN
S2.3 ROOF FRAMING PLAN
S3.0 FOUNDATION DETAILS
S4.0 FLOOR FRAMING DETAILS
S4.1 FLOOR FRAMING DETAILS
S5.0 ROOF FRAMING DETAILS
ELECTRICAL
E0.0 ELECTRICAL SYMBOLS & DETAILS
E1.0 1ST & 2ND FLOOR LIGHTING PLANS
E1.1 1ST & 2ND FLOOR PWR PLANS
E1.2 3RD FLOOR LTG/PWR PLANS
E2.0 TYPICAL UNIT PLANS
E3.0 POWER RISER DIAGRAM & SCHEDULES
PLUMBING
P1.0 FOUNDATION PLUMBING PLAN
P1.1 PLUMBING 1ST FLOOR PLAN
P1.2 PLUMBING 2ND FLOOR PLAN
P1.3 PLUMBING 3RD FLOOR PLAN
P2.0 LARGE SCALE TYP. UNIT PLUMBING PLANS
P3.0 PLUMBING DETAILS & SCHEDULES
N
2
N
D
E
H W Y 2 0
H W Y 33
W MAIN ST
E 7TH N
PROJECT
LOCATION
no. description date
As per section 1107 one unit needs to be an accessible unit, 2% need to be Type A units and the
remainder Type B.
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
8
:
4
7
P
M
CR1.1
CODE REVIEW
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
2018 IBC BUILDING CODE REVIEW
USE AND OCCUPANCY
DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. THESE DOCUMENTS ARE NOT TO BE USED IN WHOLE OR IN PART
FOR ANY PROJECT OR PURPOSE WHATSOEVER WITHOUT THE PRIOR SPECIFIC WRITTEN
AUTHORIZATION OF GPC ARCHITECTS. REGARDLESS OF ANY NOTES WITHIN THE DRAWINGS,
SPECIFICATIONS, AND/OR PRODUCT SUBMITTALS, THIS PROJECT SHALL COMPLY WITH THE 2018
INTERNATIONAL BUILDING CODE (IBC). IN THE EVENT OF A CONFLICT OR DISCREPANCY WITH
THESE PROPOSED PLANS AND THE 2018 IBC, NOTIFY THE ARCHITECT IMMEDIATELY.
GENERAL PROJECT INFORMATION
BUILDING ONWER: TETON RIVER LOFTS, LLC
PROJECT ADDRESS:LORENE ST., REXBURG, IDAHO
CONSTRUCTION TYPE:V-B
PROJECT DESCRIPTION
THE PROPOSED PROJECT CONSISTS OF A MULTI-FAMILY RESIDENTIAL STRUCTURE INCLUDING 24
DWELLING UNITS ON THREE FLOORS. THE GROUND FLOOR IS APPROXIMATELY 7,154 S.F. AND THE
TWO UPPER TWO FLOORS ARE APPROXIMATELY 7,024 S.F. EACH. THE PROPOSED BUILDING IS
INTENDED TO BE CONSTRUCTED MULTIPLE TIMES ON THE SITE AS A PROTOTYPE. THE BUILDING
WILL BE CONSTRUCTED USING CONVENTIONAL WOOD FRAMED METHODS. THE STRUCTURE WILL
BE FIRE SPRINKLERED WITH REQUIRED FIRE-RESISTANCE-RATED PARTITIONS AND FIRE-
RESISTANCE-RATED BARRIERS. SITE IMPROVEMENTS INCLUDE SIDEWALKS, PARKING AREAS,
LANDSCAPING AND RELATED WORK.
SITE AND ZONING
APPLICABLE OCCUPANCY CLASSIFICATION GROUP(S):
310.3 RESIDENTIAL GROUP R-2.
RESIDENTIAL GROUP R-2 OCCUPANCIES CONTAINING SLEEPING UNITS OR MORE THAN
TWO DWELLING UNITS WHERE THE OCCUPANTS ARE PRIMARILY PERMANENT IN NATURE,
INCLUDING:
APARTMENT HOUSES
CHAPTER 3
SPECIAL DETAILED REQUIREMENTS
BASED ON OCCUPANCY AND USE
420.2 SEPARATION WALLS.
WALLS SEPARATING DWELLING UNITS IN THE SAME BUILDING,WALLS SEPARATING SLEEPING
UNITS IN THE SAME BUILDING AND WALLS SEPARATING DWELLING OR SLEEPING UNITS FROM
OTHER OCCUPANCIES CONTIGUOUS TO THEM IN THE SAME BUILDING SHALL BE CONSTRUCTED
AS FIRE PARTITIONS IN ACCORDANCE WITH SECTION 708.
420.3 HORIZONTAL SEPARATION.
FLOOR ASSEMBLIES SEPARATING DWELLING UNITS IN THE SAME BUILDINGS, FLOOR ASSEMBLIES
SEPARATING SLEEPING UNITS IN THE SAME BUILDING AND FLOOR ASSEMBLIES SEPARATING
DWELLING OR SLEEPING UNITS FROM OTHER OCCUPANCIES CONTIGUOUS TO THEM IN THE SAME
BUILDING SHALL BE CONSTRUCTED AS HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION
711.
[F] 420.4 AUTOMATIC SPRINKLER SYSTEM.
GROUP R OCCUPANCIES SHALL BE EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER
SYSTEM IN ACCORDANCE WITH SECTION 903.2.8. QUICK-RESPONSE OR RESIDENTIAL AUTOMATIC
SPRINKLERS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 903.3.2.
[F] 420.5 FIRE ALARM SYSTEMS AND SMOKE ALARMS.
FIRE ALARM SYSTEMS AND SMOKE ALARMS SHALL BE PROVIDED IN GROUP R-2 OCCUPANCIES IN
ACCORDANCE WITH SECTION 907.2.9. SINGLE-OR MULTIPLE-STATION SMOKE ALARMS SHALL BE
PROVIDED IN GROUPS R-2 IN ACCORDANCE WITH SECTION 907.2.10.
420.9 GROUP R COOKING FACILITIES.
IN GROUP R OCCUPANCIES, COOKING APPLIANCES USED FOR DOMESTIC COOKING OPERATIONS
SHALL BE IN ACCORDANCE WITH SECTION 917.2 OF THE INTERNATIONAL MECHANICAL CODE.
CHAPTER 4
FIRE AND SMOKE PROTECTION
SYSTEMS
705.2.3.1 BALCONIES AND SIMILAR PROJECTIONS
BALCONIES AND SIMILAR PROJECTIONS OF COMBUSTIBLE CONSTRUCTION OTHER THAN FIRE-
RETARDANT-TREATED WOOD SHALL BE FIRE-RESISTANCE RATED WHERE REQUIRED BY TABLE
601 FOR FLOOR CONSTRUCTION OR SHALL BE OF HEAVY TIMBER CONSTRUCTION IN
ACCORDANCE WITH SECTION 2304.11. THE AGGREGATE LENGTH OF THE PROJECTIONS SHALL NOT
EXCEED 50 PERCENT OF THE BUILDING'S PERIMETER ON EACH FLOOR.
EXCEPTIONS:
3. BALCONIES AND SIMILAR PROJECTIONS ON BUILDINGS OF TYPES III, IV AND V
CONSTRUCTION SHALL BE PERMITTED TO BE OF TYPE V CONSTRUCTION AND SHALL NOT
BE REQUIRED TO HAVE A FIRE-RESISTANCE RATING WHERE SPRINKLER PROTECTION IS
EXTENDED TO THESE AREAS.
708.3 FIRE-RESISTANCE RATING
FIRE PARTITIONS SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 1 HOUR.
EXCEPTIONS:
CORRIDOR WALLS PERMITTED TO HAVE A 1/2-HOUR FIRE-RESISTANCE RATING BY TABLE 1020.1.
1. DWELLING UNIT AND SLEEPING UNIT SEPARATIONS IN BUILDINGS OF TYPES IIB, IIIB AND
VB CONSTRUCTION SHALL HAVE FIRE-RESISTANCE RATINGS OF NOT LESS THAN 1/2 HOUR
IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN
ACCORDANCE WITH SECTION 903.3.1.1.
708.4 CONTINUITY
FIRE PARTITIONS SHALL EXTEND FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING
ASSEMBLY BELOW AND BE SECURELY ATTACHED TO ONE OF THE FOLLOWING:
1. THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, DECK OR SLAB ABOVE.
2. THE UNDERSIDE OF A FLOOR/CEILING OR ROOF/CEILING ASSEMBLY HAVING A FIRE-
RESISTANCE RATING THAT IS NOT LESS THAN THE FIRE-RESISTANCE RATING OF
THE FIRE PARTITION.
EXCEPTIONS:
1. FIRE PARTITIONS SHALL NOT BE REQUIRED TO EXTEND INTO A CRAWL SPACE BELOW
WHERE THE FLOOR ABOVE THE CRAWL SPACE HAS A MINIMUM 1-HOUR FIRE-RESISTANCE
RATING.
2. FIRE PARTITIONS SERVING AS A CORRIDOR WALL SHALL NOT BE REQUIRED TO EXTEND
ABOVE THE LOWER MEMBRANE OF A CORRIDOR CEILING PROVIDED THAT
THE CORRIDOR CEILING MEMBRANE IS EQUIVALENT TO CORRIDOR WALL MEMBRANE,
AND EITHER OF THE FOLLOWING CONDITIONS IS MET:
3. THE ROOM-SIDE MEMBRANE OF THE CORRIDOR WALL EXTENDS TO THE UNDERSIDE OF
THE FLOOR OR ROOF SHEATHING, DECK OR SLAB OF A FIRE-RESISTANCE-RATED FLOOR
OR ROOF ABOVE.
4. THE BUILDING IS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED
THROUGHOUT IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2,
INCLUDING AUTOMATIC SPRINKLERS INSTALLED IN THE SPACE BETWEEN THE TOP OF
THE FIRE PARTITION AND UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, DECK OR
SLAB ABOVE.
711.2.4.3 DWELLING UNITS AND SLEEPING UNITS
HORIZONTAL ASSEMBLIES SERVING AS DWELLING OR SLEEPING UNIT SEPARATIONS IN
ACCORDANCE WITH SECTION 420.3 SHALL BE NOT LESS THAN 1-HOUR FIRE-RESISTANCE-RATED
CONSTRUCTION.
EXCEPTION:HORIZONTAL ASSEMBLIES SEPARATING DWELLING UNITS AND SLEEPING
UNITS SHALL BE NOT LESS THAN 1/2-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION IN A
BUILDING OF TYPES IIB, IIIB AND VB CONSTRUCTION, WHERE THE BUILDING IS EQUIPPED
THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1.
SECTION 713 SHAFT ENCLOSURES
713.2 CONSTRUCTION
SHAFT ENCLOSURES SHALL BE CONSTRUCTED AS FIRE BARRIERS IN ACCORDANCE WITH SECTION
707 OR HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711, OR BOTH.
713.4 FIRE-RESISTANCE RATING
SHAFT ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 2 HOURS
WHERE CONNECTING FOUR STORIES OR MORE, AND NOT LESS THAN 1 HOUR WHERE
CONNECTING LESS THAN FOUR STORIES. THE NUMBER OF STORIES CONNECTED BY THE SHAFT
ENCLOSURE SHALL INCLUDE ANY BASEMENTS BUT NOT ANY MEZZANINES.SHAFT
ENCLOSURES SHALL HAVE A FIRE-RESISTANCE RATING NOT LESS THAN THE FLOOR ASSEMBLY
PENETRATED, BUT NEED NOT EXCEED 2 HOURS.SHAFT ENCLOSURES SHALL MEET THE
REQUIREMENTS OF SECTION 703.2.1.
716.2.6 FIRE DOOR HARDWARE AND CLOSURES
FIRE DOOR HARDWARE AND CLOSURES SHALL BE INSTALLED ON FIRE DOOR ASSEMBLIES IN
ACCORDANCE WITH THE REQUIREMENTS OF THIS SECTION.
CHAPTER 7
FIRE PROTECTION AND LIFE
SAFETY SYSTEMS
[F] 903.3.1.2 NFPA 13R SPRINKLER SYSTEMS.
AUTOMATIC SPRINKLER SYSTEMS IN GROUP R OCCUPANCIES UP TO AND INCLUDING FOUR
STORIES IN HEIGHT IN BUILDINGS NOT EXCEEDING 60 FEET (18 288 MM) IN HEIGHT ABOVE GRADE
PLANE SHALL BE PERMITTED TO BE INSTALLED THROUGHOUT IN ACCORDANCE WITH NFPA 13R.
THE NUMBER OF STORIES OF GROUP R OCCUPANCIES CONSTRUCTED IN ACCORDANCE WITH
SECTIONS 510.2 AND 510.4 SHALL BE MEASURED FROM THE HORIZONTAL ASSEMBLY CREATING
SEPARATE BUILDINGS.
[F] 903.3.1.2.1 BALCONIES AND DECKS.
SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXTERIOR BALCONIES, DECKS AND GROUND
FLOOR PATIOS OF DWELLING UNITS AND SLEEPING UNITS WHERE EITHER OF THE FOLLOWING
CONDITIONS EXISTS:
1. THE BUILDING IS OF TYPE V CONSTRUCTION, PROVIDED THAT THERE IS A ROOF OR DECK
ABOVE.
2. EXTERIOR BALCONIES, DECKS AND GROUND FLOOR PATIOS OF DWELLING
UNITS AND SLEEPING UNITS ARE CONSTRUCTED IN ACCORDANCE WITH SECTION
705.2.3.1, EXCEPTION 3.
SIDEWALL SPRINKLERS THAT ARE USED TO PROTECT SUCH AREAS SHALL BE PERMITTED TO BE
LOCATED SUCH THAT THEIR DEFLECTORS ARE WITHIN 1 INCH (25 MM) TO 6 INCHES (152 MM)
BELOW THE STRUCTURAL MEMBERS AND A MAXIMUM DISTANCE OF 14 INCHES (356 MM) BELOW
THE DECK OF THE EXTERIOR BALCONIES AND DECKS THAT ARE CONSTRUCTED OF OPEN WOOD
JOIST CONSTRUCTION.
CHAPTER 9
MEANS OF EGRESS
SECTION 1004 OCCUPANT LOAD
TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT.
RESIDENTIAL: 200 GROSS
1005.3 REQUIRED CAPACITY BASED ON OCCUPANT LOAD
1005.3.1 STAIRWAYS.
THE CAPACITY, IN INCHES, OF MEANS OF EGRESS STAIRWAYS SHALL BE CALCULATED BY
MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH STAIRWAYS BY A MEANS OF
EGRESS CAPACITY FACTOR OF 0.3 INCH (7.6 MM) PER OCCUPANT. WHERE STAIRWAYS SERVE
MORE THAN ONE STORY, ONLY THE OCCUPANT LOAD OF EACH STORY CONSIDERED INDIVIDUALLY
SHALL BE USED IN CALCULATING THE REQUIRED CAPACITY OF THE STAIRWAYS SERVING
THAT STORY.
EXCEPTIONS:
1.FOR OTHER THAN GROUP H AND I-2 OCCUPANCIES, THE CAPACITY, IN INCHES, OF MEANS
OF EGRESS STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT
LOAD SERVED BY SUCH STAIRWAYS BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.2 INCH
(5.1 MM) PER OCCUPANT IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC
SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 AND AN
EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM IN ACCORDANCE WITH SECTION
907.5.2.2.
1005.3.2 OTHER EGRESS COMPONENTS
THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL
BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY
A MEANS OF EGRESS CAPACITY FACTOR OF 0.2 INCH (5.1 MM) PER OCCUPANT.
EXCEPTIONS:
1. FOR OTHER THAN GROUP H AND I-2 OCCUPANCIES, THE CAPACITY, IN INCHES, OF MEANS OF
EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING
THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF EGRESS CAPACITY
FACTOR OF 0.15 INCH (3.8 MM) PER OCCUPANT IN BUILDINGS EQUIPPED THROUGHOUT WITH
AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION
903.3.1.1 OR 903.3.1.2 AND AN EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM IN
ACCORDANCE WITH SECTION 907.5.2.2.
1019.3 OCCUPANCIES OTHER THAN GROUPS I-2 AND I-3.
IN OTHER THAN GROUP I-2 AND I-3 OCCUPANCIES, FLOOR OPENINGS CONTAINING EXIT ACCESS
STAIRWAYS OR RAMPS THAT DO NOT COMPLY WITH ONE OF THE CONDITIONS LISTED IN THIS
SECTION SHALL BE ENCLOSED WITH A SHAFT ENCLOSURE CONSTRUCTED IN ACCORDANCE
WITH SECTION 713.
SECTION 1020 CORRIDORS
1020.1 CONSTRUCTION.
CORRIDORS SHALL BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLE 1020.1.
THE CORRIDOR WALLS REQUIRED TO BE FIRE-RESISTANCE RATED SHALL COMPLY WITH SECTION
708 FOR FIRE PARTITIONS.
TABLE 1020.1.
CORRIDOR FIRE-RESISTANCE RATING.
OCCUPANCY: R-2
OCCUPANT LOAD: GREATER THAN 10
WITH SPRINKLER SYSTEM: .5 FOR BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC
SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 WHERE ALLOWED.
1020.2 WIDTH AND CAPACITY.
THE REQUIRED CAPACITY OF CORRIDORS SHALL BE DETERMINED AS SPECIFIED IN SECTION
1005.1, BUT THE MINIMUM WIDTH SHALL BE NOT LESS THAN THAT SPECIFIED IN TABLE 1020.2.
TABLE 1020.2
MINIMUM CORRIDOR WIDTH.
ANY FACILITY NOT LISTED IN THIS TABLE: MINIMUM WIDTH: 44 INCHES.
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
1023.2 CONSTRUCTION
ENCLOSURES FOR INTERIOR EXIT STAIRWAYS AND RAMPS SHALL BE CONSTRUCTED AS FIRE
BARRIERS IN ACCORDANCE WITH SECTION 707 OR HORIZONTAL ASSEMBLIES CONSTRUCTED IN
ACCORDANCE WITH SECTION 711, OR BOTH.INTERIOR EXIT STAIRWAY AND RAMP ENCLOSURES
SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 2 HOURS WHERE CONNECTING FOUR
STORIES OR MORE AND NOT LESS THAN 1 HOUR WHERE CONNECTING LESS THAN FOUR STORIES.
THE NUMBER OF STORIES CONNECTED BY THE INTERIOR EXIT STAIRWAYS OR RAMPS SHALL
INCLUDE ANY BASEMENTS, BUT NOT ANY MEZZANINES.INTERIOR EXIT
STAIRWAYS AND RAMPS SHALL HAVE A FIRE-RESISTANCE RATING NOT LESS THAN THE FLOOR
ASSEMBLY PENETRATED, BUT NEED NOT EXCEED 2 HOURS.
CHAPTER 10ACCESSIBILITY - ICC A117.1-2017
SECTION 403.5.1 CLEAR WIDTH GENERAL. THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE SHALL BE
36 INCHES MINIMUM. THE CLEAR WIDTH OF AN EXTERIOR ACCESSIBLE ROUTE SHALL BE 48 INCHES
MINIMUM.
SECTION 404.2.2 DOORS CLEAR WIDTH. DOORWAYS SHALL HAVE A CLEAR OPENING WIDTH OF 32
INCHES MINIMUM. CLEAR OPENING WIDTH OF DOORWAYS WITH SWINGING DOORS SHALL BE
MEASURED BETWEEN THE FACE OF DOOR AND STOP, WITH THE DOOR OPEN 90 DEGREES.
ICC A117.1
ACCESSIBILITY - IBC
1102.1 DESIGN.
BUILDINGS AND FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO BE ACCESSIBLE IN
ACCORDANCE WITH THIS CODE AND ICC A117.1.
1107.2 DESIGN
DWELLING UNITS AND SLEEPING UNITS THAT ARE REQUIRED TO BE ACCESSIBLE UNITS, TYPE A
UNITS AND TYPE B UNITS SHALL COMPLY WITH THE APPLICABLE PORTIONS OF CHAPTER 11 OF ICC
A117.1. UNITS REQUIRED TO BE TYPE A UNITS ARE PERMITTED TO BE DESIGNED AND
CONSTRUCTED AS ACCESSIBLE UNITS. UNITS REQUIRED TO BE TYPE B UNITS ARE PERMITTED TO
BE DESIGNED AND CONSTRUCTED AS ACCESSIBLE UNITS OR AS TYPE A UNITS.
SECTION 1107.6.2 GROUP R-2.
1107.6.2.2 APARTMENT HOUSES, MONASTERIES AND CONVENTS.
TYPE A UNITS AND TYPE B UNITS SHALL BE PROVIDED IN APARTMENT HOUSES, MONASTERIES
AND CONVENTS IN ACCORDANCE WITH SECTIONS 1107.6.2.2.1 AND 1107.6.2.2.2. BEDROOMS IN
MONASTERIES AND CONVENTS SHALL BE COUNTED AS UNITS FOR THE PURPOSE OF
DETERMINING THE NUMBER OF UNITS. WHERE THE BEDROOMS ARE GROUPED IN SLEEPING UNITS,
ONLY ONE BEDROOM IN EACH SLEEPING UNIT SHALL COUNT TOWARD THE NUMBER OF
REQUIRED TYPE A UNITS.
1107.6.2.2.1 TYPE A UNITS.
IN GROUP R-2 OCCUPANCIES CONTAINING MORE THAN 20 DWELLING UNITS OR SLEEPING UNITS,
AT LEAST 2 PERCENT BUT NOT LESS THAN ONE OF THE UNITS SHALL BE A TYPE A UNIT. ALL
GROUP R-2 UNITS ON A SITE SHALL BE CONSIDERED TO DETERMINE THE TOTAL NUMBER OF UNITS
AND THE REQUIRED NUMBER OF TYPE A UNITS. TYPE A UNITS SHALL BE DISPERSED AMONG THE
VARIOUS CLASSES OF UNITS.
EXCEPTIONS:
1. THE NUMBER OF TYPE A UNITS IS PERMITTED TO BE REDUCED IN ACCORDANCE
WITH SECTION 1107.7.
2. EXISTING STRUCTURES ON A SITE SHALL NOT CONTRIBUTE TO THE TOTAL NUMBER OF
UNITS ON A SITE.
1107.6.2.2.2 TYPE B UNITS.
WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS INTENDED TO BE
OCCUPIED AS A RESIDENCE IN A SINGLE STRUCTURE, EVERY DWELLING UNIT AND SLEEPING
UNIT INTENDED TO BE OCCUPIED AS A RESIDENCE SHALL BE A TYPE B UNIT.
CHAPTER 11
BUILDING HEIGHT AND AREA
TABLE 504.3 MAX ALLOWABLE BUILDING HEIGHT SPRINKLERED: 60'
ACTUAL HEIGHT:37'
TABLE 504.4 MAX ALLOWABLE NUMBER OF STORIES SPRINKLERED, TYPE V-B: 3 STORIES
ACTUAL NUMBER OF STORIES: 3 STORIES
TABLE 506.2 MAX ALLOWABLE AREA SPRINKLERED: 7,000 S.F. (W/ NFPA 13R SPRINKLER
SYSTEM.)
506.2.3 SINGLE- OCCUPANCY, MULTISTORY BUILDINGS
THE ALLOWABLE AREA OF A SINGLE-OCCUPANCY BUILDING WITH MORE THAN ONE STORY ABOVE
GRADE PLANE SHALL BE DETERMINED IN ACCORDANCE WITH EQUATION 5-2:
Aa = [At + (NS X If)] x Sa
Aa = [7,000 + (7,000 X .30) X 1 = 9,100 SQUARE FEET PER STORY (W/ NFPA 13R SPRINKLER SYSTEM.)
Aa = [7,000 + (7,000 X .30) X.3 = 27,300 SQUARE FEET
ACTUAL AREA:21,183 SQUARE FEET
Aa = ALLOWABLE AREA (SQUARE FEET).
At = TUBULAR ALLOWABLE AREA FACTOR (NS, S13R, S13D, OR SM VALUE, AS APPLICABLE) IN
ACCORDANCE WITH TABLE 506.2
NS = TUBULAR ALLOWABLE AREA FACTOR IN ACCORDANCE WITH TABLE 506.2 FOR A
NONSPRINKLERED BUILDING (REGARDLESS OF WETHER THE BUILDING IS SPRINKLERED).
If = AREA FACTOR INCREASE DUE TO FRONTAGE (PERCENT) AS CALCULATED IN ACCORDANCE
WITH SECTION 506.3
Sa = ACTUAL NUMBER OF BUILDING STORIES ABOVE GRADE PLANE, NOT TO EXCEED THREE. FOR
BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN
ACCORDANCE WITH SECTION 903.3.1.2, USE THE ACTUAL NUMBER OF BUILDING STORIES ABOVE
GRADE PLANE, NOT TO EXCEED FOUR.
NO INDIVIDUAL STORY SHALL EXCEED THE ALLOWABLE AREA (AA) AS DETERMINED BY EQUATION
5-2 USING THE VALUE OF SA = 1.
CHAPTER 5
ACCESSIBILITY TYPE A UNITS
SECTION 1103 TYPE A UNITS
1103.3 ACCESSIBLE ROUTE
ACCESSIBLE ROUTES WITHIN TYPE A UNITS SHALL COMPLY WITH SECTION 1103.3.
1103.3.1 LOCATION
AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ALL SPACES AND ELEMENTS THAT ARE A
PART OF THE UNIT. ACCESSIBLE ROUTES SHALL COINCIDE WITH OR BE LOCATED IN THE SAME
AREA AS A GENERAL CIRCULATION PATH.
1103.3.2 TURNING SPACE
ALL ROOMS SERVED BY AN ACCESSIBLE ROUTE SHALL PROVIDE A TURNING SPACE COMPLYING
WITH SECTION 304.
EXCEPTIONS:
A TURNING SPACE IS NOT REQUIRED IN TOILET ROOMS AND BATHROOMS THAT ARE NOT
REQUIRED TO COMPLY WITH SECTION 1103.11.2.
1. A TURNING SPACE IS NOT REQUIRED WITHIN CLOSETS OR PANTRIES THAT ARE 48
INCHES (1220 MM) MAXIMUM IN DEPTH.
1103.5 DOORS AND DOORWAYS
THE PRIMARY ENTRANCE DOOR TO THE UNIT, AND ALL OTHER DOORWAYS INTENDED FOR USER
PASSAGE, SHALL COMPLY WITH SECTION 404.
EXCEPTIONS:
1. THRESHOLDS AT EXTERIOR SLIDING DOORS SHALL BE PERMITTED TO BE 3/4 INCH (19 MM)
MAXIMUM IN HEIGHT, PROVIDED THEY ARE BEVELED WITH A SLOPE NOT GREATER THAN
1:2.
SECTION 1103.11 TOILET AND BATHING FACILITIES. AT LEAST ONE TOILET AND BATHING FACILITY
SHALL COMPLY WITH SECTION 1103.11.2. ALL TOILET AND BATHING FACILITES SHALL COMPLY WITH
SECTION 1103.11.1.
1103.11.1 GRAB BAR AND SHOWER SEAT REINFORCEMENT
REINFORCEMENT SHALL BE PROVIDED FOR THE FUTURE INSTALLATION OF GRAB BARS
COMPLYING WITH SECTION 604.5 AT WATER CLOSETS; GRAB BARS COMPLYING WITH SECTION
607.4 AT BATHTUBS; AND FOR GRAB BARS AND SHOWER SEATS COMPLYING WITH
SECTIONS 608.3, 608.2.1.3, 608.2.2.3 AND 608.2.3.2 AT SHOWER COMPARTMENTS.
1103.11.2 GENERAL
AT LEAST ONE TOILET AND BATHING FACILITY SHALL COMPLY WITH SECTION 1103.11.2. AT LEAST
ONE LAVATORY, ONE WATER CLOSET AND EITHER A BATHTUB OR SHOWER WITHIN THE UNIT
SHALL COMPLY WITH SECTION 1103.11.2. THE ACCESSIBLE TOILET AND BATHING FIXTURES SHALL
BE IN A SINGLE TOILET/BATHING AREA, SUCH THAT TRAVEL BETWEEN FIXTURES DOES NOT
REQUIRE TRAVEL THROUGH OTHER PARTS OF THE UNIT.
1103.11.2.1 DOORS
DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE FOR ANY FIXTURE.
1103.11.2.2 LAVATORY
LAVATORIES SHALL COMPLY WITH SECTION 606.
1103.11.2.3 MIRRORS
MIRRORS ABOVE LAVATORIES REQUIRED TO COMPLY WITH SECTION 1103.11.2.2 SHALL HAVE THE
BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FLOOR.
1103.11.2.4 WATER CLOSET
WATER CLOSETS SHALL COMPLY WITH SECTION 1103.11.2.4.
1103.11.2.4.4 CLEARANCE OVERLAP
THE REQUIRED CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE
WATER CLOSET, ASSOCIATED GRAB BARS, PAPER DISPENSERS, COAT HOOKS, SHELVES,
ACCESSIBLE ROUTES, CLEAR FLOOR SPACE REQUIRED AT OTHER FIXTURES, AND THE
WHEELCHAIR TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED
WITHIN THE REQUIRED WATER CLOSET CLEARANCE.
1103.11.2.5 BATHING FIXTURES
THE ACCESSIBLE BATHING FIXTURE SHALL BE A BATHTUB COMPLYING WITH SECTION
1103.11.2.5.1 OR A SHOWER COMPARTMENT COMPLYING WITH SECTION 1103.11.2.5.2.
1103.12 KITCHENS AND KITCHENETTES
KITCHENS AND KITCHENETTES SHALL COMPLY WITH SECTION 1103.12.
1103.12.1 CLEARANCE
CLEARANCE COMPLYING WITH SECTION 1103.12.1 SHALL BE PROVIDED.
1103.12.1.1 MINIMUM CLEARANCE
CLEARANCE BETWEEN ALL OPPOSING BASE CABINETS, COUNTER TOPS, APPLIANCES, OR WALLS
WITHIN KITCHEN WORK AREAS SHALL BE 40 INCHES (1015MM) MINIMUM.
1103.12.1.2 U-SHAPED KITCHENS
IN KITCHENS WITH COUNTERS, APPLIANCES, OR CABINETS ON THREE CONTIGUOUS SIDES,
CLEARANCE BETWEEN ALL OPPOSING BASE CABINETS, COUNTERTOPS, APPLIANCES, OR WALLS
WITHIN KITCHEN WORK AREAS SHALL BE 60 INCHES (1525 MM) MINIMUM.
1103.12.3 WORK SURFACE
AT LEAST ONE SECTION OF COUNTER SHALL PROVIDE A WORK SURFACE 30 INCHES (760 MM)
MINIMUM IN LENGTH COMPLYING WITH SECTION 1103.12.3.
1103.12.3.1 CLEAR FLOOR SPACE
A CLEAR FLOOR SPACE, POSITIONED FOR A FORWARD APPROACH TO THE WORK SURFACE, SHALL
BE PROVIDED. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 306 SHALL BE PROVIDED.
THE CLEAR FLOOR SPACE SHALL BE CENTERED ON THE WORK SURFACE.
EXCEPTION:CABINETRY SHALL BE PERMITTED UNDER THE WORK SURFACE, PROVIDED THE
FOLLOWING CRITERIA ARE MET:
THE CABINETRY CAN BE REMOVED WITHOUT REMOVAL OR REPLACEMENT OF THE WORK
SURFACE,
1. THE FLOOR FINISH EXTENDS UNDER THE CABINETRY, AND
2. THE WALLS BEHIND AND SURROUNDING THE CABINETRY ARE FINISHED.
1103.12.3.2 HEIGHT
THE WORK SURFACE SHALL BE 34 INCHES (865 MM) MAXIMUM ABOVE THE FLOOR.
1103.12.4 SINK
THE SINK SHALL COMPLY WITH SECTION 1103.12.4.
1103.12.4.1 CLEAR FLOOR SPACE
A CLEAR FLOOR SPACE, POSITIONED FOR A FORWARD APPROACH TO THE SINK, SHALL BE
PROVIDED. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 306 SHALL BE PROVIDED.
EXCEPTIONS:
THE REQUIREMENT FOR KNEE AND TOE CLEARANCE SHALL NOT APPLY TO MORE THAN ONE BOWL
OF A MULTI-BOWL SINK.
1. CABINETRY SHALL BE PERMITTED TO BE ADDED UNDER THE SINK, PROVIDED THE
FOLLOWING CRITERIA ARE MET:
2.1THE CABINETRY CAN BE REMOVED WITHOUT REMOVAL OR REPLACEMENT OF THE
SINK,
2.2THE FLOOR FINISH EXTENDS UNDER THE CABINETRY, AND
2.3THE WALLS BEHIND AND SURROUNDING THE CABINETRY ARE FINISHED.
1103.12.4.2 HEIGHT
THE FRONT OF THE SINK SHALL BE 34 INCHES (865 MM) MAXIMUM ABOVE THE FLOOR, MEASURED
TO THE HIGHER OF THE RIM OR COUNTER SURFACE.
ICC A117.1
ACCESSIBILITY TYPE B UNITS
1104 TYPE B UNITS
1104.3 ACCESSIBLE ROUTE
ACCESSIBLE ROUTES WITHIN TYPE B UNITS SHALL COMPLY WITH SECTION 1104.3.
1104.3.1 LOCATION
AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ALL SPACES AND ELEMENTS THAT ARE A
PART OF THE UNIT. ACCESSIBLE ROUTES SHALL COINCIDE WITH OR BE LOCATED IN THE SAME
AREA AS A GENERAL CIRCULATION PATH.
1104.5 DOORS AND DOORWAYS
DOORS AND DOORWAYS SHALL COMPLY WITH SECTION 1104.5.
1104.5.1 PRIMARY ENTRANCE DOOR
THE PRIMARY ENTRANCE DOOR TO THE UNIT SHALL COMPLY WITH SECTION 404.
1104.5.2 USER PASSAGE DOORWAYS
DOORWAYS INTENDED FOR USER PASSAGE SHALL COMPLY WITH SECTION 1104.5.2.
1104.5.2.1 CLEAR WIDTH
DOORWAYS SHALL HAVE A CLEAR OPENING OF 313/4 INCHES (805 MM) MINIMUM. CLEAR OPENING
OF SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND STOP, WITH
THE DOOR OPEN 90 DEGREES.
1104.10 LAUNDRY EQUIPMENT
WASHING MACHINES AND CLOTHES DRYERS SHALL COMPLY WITH SECTION 1104.10.
1104.10.1 CLEAR FLOOR SPACE
A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305.3, SHALL BE PROVIDED. A PARALLEL
APPROACH SHALL BE PROVIDED FOR A TOP LOADING MACHINE. A FORWARD OR PARALLEL
APPROACH SHALL BE PROVIDED FOR A FRONT LOADING MACHINE.
1104.11 TOILET AND BATHING FACILITIES
TOILET AND BATHING FIXTURES SHALL COMPLY WITH SECTION 1104.11.
EXCEPTION:FIXTURES ON LEVELS NOT REQUIRED TO BE ACCESSIBLE.
1104.11.1 GRAB BAR AND SHOWER SEAT REINFORCEMENT
REINFORCEMENT SHALL BE PROVIDED FOR THE FUTURE INSTALLATION OF GRAB BARS AND
SHOWER SEATS AT WATER CLOSETS, BATHTUBS, AND SHOWER COMPARTMENTS. WHERE WALLS
ARE LOCATED TO PERMIT THE INSTALLATION OF GRAB BARS AND SEATS COMPLYING
WITH SECTION 604.5 AT WATER CLOSETS; GRAB BARS COMPLYING WITH SECTION 607.4 AT
BATHTUBS; AND FOR GRAB BARS AND SHOWER SEATS COMPLYING WITH
SECTIONS, 608.3, 608.2.1.3, 608.2.2.3 AND 608.2.3.2 AT SHOWER COMPARTMENTS; REINFORCEMENT
SHALL BE PROVIDED FOR THE FUTURE INSTALLATION OF GRAB BARS AND SEATS COMPLYING
WITH THOSE REQUIREMENTS.
1104.11.2 CLEAR FLOOR SPACE
CLEAR FLOOR SPACES REQUIRED BY SECTION 1104.11.3.1 (OPTION A) OR 1104.11.3.2 (OPTION B)
SHALL COMPLY WITH SECTIONS 1104.11.2 AND 1104.1.1.
1104.11.2.1 DOORS
DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE FOR ANY FIXTURE.
1104.11.3 TOILET AND BATHING AREAS
EITHER ALL TOILET AND BATHING AREAS PROVIDED SHALL COMPLY WITH SECTION
1104.11.3.1 (OPTION A), OR ONE TOILET AND BATHING AREA SHALL COMPLY WITH SECTION
1104.11.3.2 (OPTION B).
1104.12 KITCHENS AND KITCHENETTES
KITCHENS AND KITCHENETTES SHALL COMPLY WITH SECTION 1104.12.
1104.12.1 CLEARANCE
CLEARANCE COMPLYING WITH SECTION 1104.12.1 SHALL BE PROVIDED.
1104.12.1.1 MINIMUM CLEARANCE
CLEARANCE BETWEEN ALL OPPOSING BASE CABINETS, COUNTER TOPS, APPLIANCES, OR WALLS
WITHIN KITCHEN WORK AREAS SHALL BE 40 INCHES (1015MM) MINIMUM.
1104.12.1.2 U-SHAPED KITCHENS
IN KITCHENS WITH COUNTERS, APPLIANCES, OR CABINETS ON THREE CONTIGUOUS SIDES,
CLEARANCE BETWEEN ALL OPPOSING BASE CABINETS, COUNTERTOPS, APPLIANCES, OR WALLS
WITHIN KITCHEN WORK AREAS SHALL BE 60 INCHES (1525 MM) MINIMUM.
1104.12.2 CLEAR FLOOR SPACE
CLEAR FLOOR SPACE AT APPLIANCES SHALL COMPLY WITH SECTIONS 1104.12.2 AND 305.3.
1104.12.2.1 SINK
A CLEAR FLOOR SPACE, POSITIONED FOR A PARALLEL APPROACH TO THE SINK, SHALL BE
PROVIDED. THE CLEAR FLOOR SPACE SHALL BE CENTERED ON THE SINK BOWL.
EXCEPTION:A SINK WITH A FORWARD APPROACH COMPLYING WITH SECTION 1003.12.4.1.
1104.12.2.2 DISHWASHER
A CLEAR FLOOR SPACE, POSITIONED FOR A PARALLEL OR FORWARD APPROACH TO THE
DISHWASHER, SHALL BE PROVIDED. THE DISHWASHER DOOR IN THE OPEN POSITION SHALL NOT
OBSTRUCT THE CLEAR FLOOR SPACE FOR THE DISHWASHER.
1104.12.2.3 COOKTOP
COOKTOPS SHALL COMPLY WITH SECTION 1104.12.2.3.
1104.12.2.3.1 APPROACH
A CLEAR FLOOR SPACE, POSITIONED FOR A PARALLEL OR FORWARD APPROACH TO THE
COOKTOP, SHALL BE PROVIDED.
1104.12.2.3.2 FORWARD APPROACH
WHERE THE CLEAR FLOOR SPACE IS POSITIONED FOR A FORWARD APPROACH, KNEE AND TOE
CLEARANCE COMPLYING WITH SECTION 306 SHALL BE PROVIDED. THE UNDERSIDE OF THE
COOKTOP SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PREVENT BURNS, ABRASIONS,
OR ELECTRICAL SHOCK.
1104.12.2.3.3 PARALLEL APPROACH
WHERE THE CLEAR FLOOR SPACE IS POSITIONED FOR A PARALLEL APPROACH, THE CLEAR FLOOR
SPACE SHALL BE CENTERED ON THE APPLIANCE.
1104.12.2.4 OVEN
A CLEAR FLOOR SPACE, POSITIONED FOR A PARALLEL OR FORWARD APPROACH ADJACENT TO
THE OVEN SHALL BE PROVIDED. THE OVEN DOOR IN THE OPEN POSITION SHALL NOT OBSTRUCT
THE CLEAR FLOOR SPACE FOR THE OVEN.
1104.12.2.5 REFRIGERATOR/FREEZER
A CLEAR FLOOR SPACE, POSITIONED FOR A PARALLEL APPROACH TO THE
REFRIGERATOR/FREEZER, SHALL BE PROVIDED. THE CENTERLINE OF THE CLEAR FLOOR SPACE
SHALL BE OFFSET 24 INCHES (610 MM) MAXIMUM FROM THE CENTERLINE OF THE APPLIANCE.
ICC A117.1
ZONING DISTRICT:MEDIUM DENSITY RESIDENTIAL 2
PERMITTED USES:MULTI-FAMILY
FRONT YARD SETBACK:25'
REAR YARD SETBACK:20'
SIDE YARD SETBACK:6" OF SETBACK FOR EVERY FOOT OF BUILDING HEIGHT
MAXIMUM BUILDING HEIGHT:40'
MAXIMUM LOT COVERAGE:80%
MINIMUM LANDSCAPING:20%
SECTION 1206 SOUND TRANSMISSION
1206.1 SCOPE
THIS SECTION SHALL APPLY TO COMMON INTERIOR WALLS, PARTITIONS AND FLOOR/CEILING
ASSEMBLIES BETWEEN ADJACENT DWELLING UNITS AND SLEEPING UNITS OR BETWEEN DWELLING
UNITS AND SLEEPING UNITS AND ADJACENT PUBLIC AREAS SUCH AS HALLS, CORRIDORS,
STAIRWAYS OR SERVICE AREAS.
1206.2 AIRBORNE SOUND
WALLS, PARTITIONS AND FLOOR-CEILING ASSEMBLIES SEPARATING DWELLING UNITS AND
SLEEPING UNITS FROM EACH OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND
TRANSMISSION CLASS OF NOT LESS THAN 50, OR NOT LESS THAN 45 IF FIELD TESTED, FOR
AIRBORNE NOISE WHERE TESTED IN ACCORDANCE WITH ASTM E90. PENETRATIONS OR OPENINGS
IN CONSTRUCTION ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES; RECESSED CABINETS;
BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR EXHAUST DUCTS SHALL BE SEALED, LINED,
INSULATED OR OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS. THIS REQUIREMENT
SHALL NOT APPLY TO ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT FITTING TO
THE FRAME AND SILL.
1206.3 STRUCTURE-BORNE SOUND
FLOOR-CEILING ASSEMBLIES BETWEEN DWELLING UNITS AND SLEEPING UNITS OR BETWEEN
A DWELLING UNIT OR SLEEPING UNIT AND A PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE
SHALL HAVE AN IMPACT INSULATION CLASS RATING OF NOT LESS THAN 50, OR NOT LESS THAN 45
IF FIELD TESTED, WHERE TESTED IN ACCORDANCE WITH ASTM E492.
CHAPTER 12INTERIOR ENVIRONMENT
no. description date
Damp proofing and waterproofing to comply with section 1805.
Site grading needs to meet the requirements of section 1804.4
UP UP
GA WP3267 GA WP3267GA WP3267
GA WP3267 GA WP3267GA WP3267 GA WP3267
GA WP3267 GA WP3267GA WP3267 GA WP3267
GA WP3267 GA WP3267GA WP3267 GA WP3267 GA WP3267 GA WP3267
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA WP3267 GA WP3267GA WP3267 GA WP3267
GA WP3267 GA WP3267GA WP3267 GA WP3267 GA WP3267 GA WP3267
GA WP3247GA WP3247
GA WP3247GA WP3247
GA WP3247GA WP3247
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA WP3116 GA WP3116
B
B
C
C
D
D
E
E
G
G
1 1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
8 8
UNIT 2
102
UNIT 1
106
UNIT 1
104
UNIT 3
108
UNIT 2
101
UNIT 1
105
UNIT 1
103
UNIT 2
107
WO
R
K
S
U
R
F
A
C
E
UNIT 202
302 SIMILAR
RESIDENTIAL 200
GROSS
926 SQ FT GROSS
5 OCCUPANTS
UNIT 204
304 SIMILAR
RESIDENTIAL 200
GROSS
578 SQ FT GROSS
3 OCCUPANTS
UNIT 208
308 SIMILAR
RESIDENTIAL 200
GROSS
1,198 SQ FT GROSS
6 OCCUPANTS
UNIT 206
306 SIMILAR
RESIDENTIAL 200
GROSS
578 SQ FT GROSS
3 OCCUPANTS
UNIT 201
301 SIMILAR
RESIDENTIAL 200
GROSS
926 SQ FT GROSS
5 OCCUPANTS
UNIT 203
303 SIMILAR
RESIDENTIAL 200
GROSS
578 SQ FT GROSS
3 OCCUPANTS
UNIT 205
305 SIMILAR
RESIDENTIAL 200
GROSS
578 SQ FT GROSS
3 OCCUPANTS
UNIT 207
307 SIMILAR
RESIDENTIAL 200
GROSS
926 SQ FT GROSS
5 OCCUPANTS
5
34
6
5
3 3
3 3
32
5
4851
EGRESS DOOR SIZE
OCCUPANTS TOTAL: 51
51 OCC X 0.2IN = 10.2IN
WIDTH PROVIDED: 36IN
EGRESS STAIR SIZE
OCCUPANTS PER STORY: 17
17 OCC X 0.3IN = 5.1IN
WIDTH PROVIDED: 44IN
EGRESS DOOR SIZE
OCCUPANTS TOTAL: 48
48 OCC X 0.2IN = 9.6IN
WIDTH PROVIDED: 36IN
EGRESS STAIR SIZE
OCCUPANTS PER STORY: 16
16 OCC X 0.3IN = 4.8IN
WIDTH PROVIDED: 44IN
FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5075
1 HOUR FIRE
55 TO 59 STC SOUND
1 1/4" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD I-JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
WALLS AND INTERIOR PARTITIONS, WOOD FRAMED
GA FILE NO. WP 3267
1 HOUR FIRE
50 TO 54 STC SOUND
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM SHEATHING
WALLS AND INTERIOR PARTITIONS, WOOD FRAMED
GA FILE NO. WP 3116
1 HOUR FIRE
55 TO 59 STC SOUND
TWO LAYERS 5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
2 X 4 WOOD STUDS ON SEPARATE PLATES
3 1/2" GLASS FIBER INSULATION BATTS
1" AIR SPACE
5/8" TYPE X GYPSUM WALL BOARD
WALLS AND INTERIOR PARTITIONS, WOOD FRAMED
GA FILE NO. WP 3247
1 HOUR FIRE
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM SHEATHING
WALLS AND PARTITIONS AT FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5052 AND GA FILE NO. WP 3247
1 HOUR FIRE
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
WALLS AND PARTITIONS AT FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5075 AND GA FILE NO. WP 3116
1 HOUR FIRE
1 1/4" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD I-JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
TWO LAYERS 5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
2 X 4 WOOD STUDS ON SEPARATE PLATES
3 1/2" GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
2 X 4 WOOD STUDS ON SEPARATE PLATES
3 1/2" GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM SHEATHING
WALLS AND PARTITIONS AT FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5052, GA FILE NO. FC 5075, AND GA FILE NO. WP 3267
1 HOUR FIRE
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM SHEATHING
1/2" RESILIENT CHANNELS
1/2" RESILIENT CHANNELS
FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5052
1 HOUR FIRE
55 TO 59 STC SOUND
3" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM WALL BOARD
3" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM WALL BOARD
3" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM WALL BOARD
UNIT 102
-
RESIDENTIAL 200
GROSS
926 SQ FT GROSS
5 OCCUPANTS
7
EXIT
NUMBER OF OCCUPANTS
ALTERNATE EXIT ROUTE
FUNCTION OF SPACE
(IBC TABLE 1004.1.2)
AREA OF OCCUPANCY
(SQUARE FEET)
NUMBER OF OCCUPANTS
(AREA/OCC. LOAD FACTOR)
OCCUPANCY LOAD FACTOR
(IBC TABLE 1004.1.2)
ROOM NAME AND NUMBER
FIRE
EXTINGUISHER
NUMBER OF OCCUPANTS FROM
ADJACENT STORY
EXIT ACCESS TRAVEL PATH
EXIT ACCESS TRAVEL PATH
FROM ADJACENT STORY
42
FIRE-RESISTANT-RATED
CONSTRUCTION ASSEMBLY AND
REFERENCE NUMBER
FE
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
2
7
P
M
CR1.2
CODE REVIEW
1ST FLOOR PLAN
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"CR1.2
1 CODE REVIEW 1ST FLOOR PLAN
FIRE-RATED ASSEMBLIES
CODE REVIEW PLAN LEGENDNFPA 13R SPRINKLER SYSTEM
THIS PROJECT SHALL BE EQUIPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED
THROUGHOUT IN ACCORDANCE WITH NFPA 13R.
no. description date
Exit access travel distance maximum of 250'.
DN DN
GA WP3267 GA WP3267GA WP3267
GA WP3267 GA WP3267GA WP3267 GA WP3267
GA WP3267 GA WP3267GA WP3267 GA WP3267
GA WP3267 GA WP3267GA WP3267 GA WP3267 GA WP3267 GA WP3267
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA WP3267 GA WP3267GA WP3267 GA WP3267
GA WP3267 GA WP3267GA WP3267 GA WP3267 GA WP3267 GA WP3267
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA
W
P
3
2
4
7
GA WP3247GA WP3247
GA WP3247GA WP3247
GA WP3116 GA WP3116
B
B
C
C
D
D
E
E
G
G
1 1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
8 8
UNIT 2
202
UNIT 1
206
UNIT 1
204
UNIT 3
208
UNIT 2
201
UNIT 1
205
UNIT1
203
UNIT 2
207
5'
-
0
1
/
4
"
16
5
UNIT 202
302 SIMILAR
RESIDENTIAL 200
GROSS
926 SQ FT GROSS
5 OCCUPANTS
UNIT 204
304 SIMILAR
RESIDENTIAL 200
GROSS
578 SQ FT GROSS
3 OCCUPANTS
UNIT 208
308 SIMILAR
RESIDENTIAL 200
GROSS
1,198 SQ FT GROSS
6 OCCUPANTS
17
6
34
5
UNIT 206
306 SIMILAR
RESIDENTIAL 200
GROSS
578 SQ FT GROSS
3 OCCUPANTS
3 3
3 3
UNIT 201
301 SIMILAR
RESIDENTIAL 200
GROSS
926 SQ FT GROSS
5 OCCUPANTS
UNIT 203
303 SIMILAR
RESIDENTIAL 200
GROSS
578 SQ FT GROSS
3 OCCUPANTS
UNIT 205
305 SIMILAR
RESIDENTIAL 200
GROSS
578 SQ FT GROSS
3 OCCUPANTS
UNIT 207
307 SIMILAR
RESIDENTIAL 200
GROSS
926 SQ FT GROSS
5 OCCUPANTS
32
FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5075
1 HOUR FIRE
55 TO 59 STC SOUND
1 1/4" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD I-JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
WALLS AND INTERIOR PARTITIONS, WOOD FRAMED
GA FILE NO. WP 3267
1 HOUR FIRE
50 TO 54 STC SOUND
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM SHEATHING
WALLS AND INTERIOR PARTITIONS, WOOD FRAMED
GA FILE NO. WP 3116
1 HOUR FIRE
55 TO 59 STC SOUND
TWO LAYERS 5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
2 X 4 WOOD STUDS ON SEPARATE PLATES
3 1/2" GLASS FIBER INSULATION BATTS
1" AIR SPACE
5/8" TYPE X GYPSUM WALL BOARD
WALLS AND INTERIOR PARTITIONS, WOOD FRAMED
GA FILE NO. WP 3247
1 HOUR FIRE
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM SHEATHING
WALLS AND PARTITIONS AT FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5052 AND GA FILE NO. WP 3247
1 HOUR FIRE
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
WALLS AND PARTITIONS AT FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5075 AND GA FILE NO. WP 3116
1 HOUR FIRE
1 1/4" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD I-JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
TWO LAYERS 5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
2 X 4 WOOD STUDS ON SEPARATE PLATES
3 1/2" GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
2 X 4 WOOD STUDS ON SEPARATE PLATES
3 1/2" GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM SHEATHING
WALLS AND PARTITIONS AT FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5052, GA FILE NO. FC 5075, AND GA FILE NO. WP 3267
1 HOUR FIRE
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM SHEATHING
1/2" RESILIENT CHANNELS
1/2" RESILIENT CHANNELS
FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5052
1 HOUR FIRE
55 TO 59 STC SOUND
3" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM WALL BOARD
3" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM WALL BOARD
3" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM WALL BOARD
UNIT 102
-
RESIDENTIAL 200
GROSS
926 SQ FT GROSS
5 OCCUPANTS
7
EXIT
NUMBER OF OCCUPANTS
ALTERNATE EXIT ROUTE
FUNCTION OF SPACE
(IBC TABLE 1004.1.2)
AREA OF OCCUPANCY
(SQUARE FEET)
NUMBER OF OCCUPANTS
(AREA/OCC. LOAD FACTOR)
OCCUPANCY LOAD FACTOR
(IBC TABLE 1004.1.2)
ROOM NAME AND NUMBER
FIRE
EXTINGUISHER
NUMBER OF OCCUPANTS FROM
ADJACENT STORY
EXIT ACCESS TRAVEL PATH
EXIT ACCESS TRAVEL PATH
FROM ADJACENT STORY
42
FIRE-RESISTANT-RATED
CONSTRUCTION ASSEMBLY AND
REFERENCE NUMBER
FE
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
3
0
P
M
CR1.3
CODE REVIEW
2ND FLOOR
PLAN
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"CR1.3
1 CODE REVIEW 2ND FLOOR PLAN
FIRE-RATED ASSEMBLIES
CODE REVIEW PLAN LEGEND
3RD FLOOR SIMILAR
NFPA 13R SPRINKLER SYSTEM
THIS PROJECT SHALL BE EQUIPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED
THROUGHOUT IN ACCORDANCE WITH NFPA 13R.
no. description date
GA FC5075 GA FC5075GA FC5075 GA FC5075 GA FC5075GA FC5075 GA FC5075GA FC5075GA FC5052GA FC5052
GA FC5075 GA FC5075GA FC5075 GA FC5075 GA FC5075GA FC5075 GA FC5075GA FC5075GA FC5052GA FC5052
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA
W
P
3
2
6
7
GA FC5075 GA FC5075GA FC5075 GA FC5075 GA FC5075 GA FC5075 GA FC5075 GA FC5075 GA FC5075 GA FC5075
GA FC5075 GA FC5075GA FC5075 GA FC5075 GA FC5075 GA FC5075 GA FC5075 GA FC5075 GA FC5075 GA FC5075
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA
W
P
3
1
1
6
GA WP3116 GA WP3116
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
1
A5.3
________
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
1
T.O. PARAPET 3
ELEV.37' -0"
5610 37
T.O. FOOTING 96' -0"
ELEV.-4' -0"
29482
A5.3
________
T.O. PARAPET 2
ELEV.35' -9 3/4"T.O. PARAPET1
ELEV.34' -8 5/8"
2
A5.4
________1
A5.5
________1
A5.4
________2
CR1.4
________
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
BCDEG
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
F A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
1
A5.1
________2
A5.1
________
T.O. PARAPET 2
ELEV.35' -9 3/4"T.O. PARAPET1
ELEV.34' -8 5/8"
1
A5.2
________2
A5.2
________1
CR1.4
________
FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5075
1 HOUR FIRE
55 TO 59 STC SOUND
1 1/4" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD I-JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
WALLS AND INTERIOR PARTITIONS, WOOD FRAMED
GA FILE NO. WP 3267
1 HOUR FIRE
50 TO 54 STC SOUND
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM SHEATHING
WALLS AND INTERIOR PARTITIONS, WOOD FRAMED
GA FILE NO. WP 3116
1 HOUR FIRE
55 TO 59 STC SOUND
TWO LAYERS 5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
2 X 4 WOOD STUDS ON SEPARATE PLATES
3 1/2" GLASS FIBER INSULATION BATTS
1" AIR SPACE
5/8" TYPE X GYPSUM WALL BOARD
WALLS AND INTERIOR PARTITIONS, WOOD FRAMED
GA FILE NO. WP 3247
1 HOUR FIRE
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM SHEATHING
WALLS AND PARTITIONS AT FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5052 AND GA FILE NO. WP 3247
1 HOUR FIRE
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
WALLS AND PARTITIONS AT FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5075 AND GA FILE NO. WP 3116
1 HOUR FIRE
1 1/4" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD I-JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
TWO LAYERS 5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
2 X 4 WOOD STUDS ON SEPARATE PLATES
3 1/2" GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
2 X 4 WOOD STUDS ON SEPARATE PLATES
3 1/2" GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM SHEATHING
WALLS AND PARTITIONS AT FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5052, GA FILE NO. FC 5075, AND GA FILE NO. WP 3267
1 HOUR FIRE
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM WALL BOARD
WOOD STUDS
GLASS FIBER INSULATION BATTS
5/8" TYPE X GYPSUM SHEATHING
1/2" RESILIENT CHANNELS
1/2" RESILIENT CHANNELS
FLOOR-CEILING SYSTEMS, WOOD FRAMED
GA FILE NO. FC 5052
1 HOUR FIRE
55 TO 59 STC SOUND
3" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM WALL BOARD
3" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM WALL BOARD
3" GYPCRETE
1/4" SOUND REDUCTION MAT
PLYWOOD SUBFLOOR
WOOD JOISTS
3 1/2" GLASS FIBER INSULATION
1/2" RESILIENT CHANNELS
5/8" TYPE X GYPSUM WALL BOARD
UNIT 102
-
RESIDENTIAL 200
GROSS
926 SQ FT GROSS
5 OCCUPANTS
7
EXIT
NUMBER OF OCCUPANTS
ALTERNATE EXIT ROUTE
FUNCTION OF SPACE
(IBC TABLE 1004.1.2)
AREA OF OCCUPANCY
(SQUARE FEET)
NUMBER OF OCCUPANTS
(AREA/OCC. LOAD FACTOR)
OCCUPANCY LOAD FACTOR
(IBC TABLE 1004.1.2)
ROOM NAME AND NUMBER
FIRE
EXTINGUISHER
NUMBER OF OCCUPANTS FROM
ADJACENT STORY
EXIT ACCESS TRAVEL PATH
EXIT ACCESS TRAVEL PATH
FROM ADJACENT STORY
42
FIRE-RESISTANT-RATED
CONSTRUCTION ASSEMBLY AND
REFERENCE NUMBER
FE
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
2
0
/
2
0
2
2
8
:
1
0
:
3
6
A
M
CR1.4
CODE REVIEW
SECTIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"CR1.4
1 CODE REVIEW BUILDING SECTION B
1/8" = 1'-0"CR1.4
2 CODE REVIEW BUILDING SECTION F
FIRE-RATED ASSEMBLIESCODE REVIEW PLAN LEGEND
NFPA 13R SPRINKLER SYSTEM
THIS PROJECT SHALL BE EQUIPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED
THROUGHOUT IN ACCORDANCE WITH NFPA 13R.
no. description date
BCD
1
5
3
A
2
4
LIVING
102A
KITCHEN
102B
HALL
102C
LIVING
104A
KITCHEN
104B
LAUNDRY
102D
BATHROOM 1
102K
HALL
104C
LAUNDRY
104D
M. BATHROOM
104F
M. BEDROOM
104E
M. CLOSET
104G
M. BEDROOM
102E
M. CLOSET
102G
CLOSET 1
102M
BEDROOM 1
102L
MECH.
104J
MECH
102J
M. SHOWER
102H
M. BATHROOM
102F
M. SHOWER
104H
UNIT 2
102
UNIT 1
104
FIGURE 611.2
FIGURE 304.3.1.1
FIGURE 404.2.3.2(A)
FIGURE 404.2.3.2(H)
FIGURE 404.2.3.2(A)
FI
G
U
R
E
1
1
0
3
.
1
1
.
2
.
5
.
1
(
A
)
FIGURE 1103.11.2.5.1(A)
FIGURE 1103.11.2.4(C)
FI
G
U
R
E
1
1
0
3
.
1
1
.
2
.
4
(
C
)
FI
G
U
R
E
3
0
6
.
3
FIGURE 404.2.3.2(G)
FIGURE 306.3
FIGURE 404.2.3.2(H)
FIGURE 404.2.3.2(F)
FIGURE 611.2
FI
G
U
R
E
4
0
4
.
2
.
3
.
2
(
A
)
FI
G
U
R
E
3
0
4
.
3
.
2
.
1
(
A
)
FIGURE 304.3.2.1
WO
R
K
SU
R
F
A
C
E
WO
R
K
SU
R
F
A
C
E
FI
G
U
R
E
3
0
4
.
3
.
2
.
1
(
A
)
FIGURE 404.2.3.2(F)
FI
G
U
R
E
4
0
4
.
2
.
3
.
2
(
F
)
FI
G
U
R
E
4
0
4
.
2
.
3
.
2
(
G
)
FIGURE 304.3.2.1(A)
EG
1
5
3
F
2
4
LIVING
108A
KITCHEN
108B
HALL
108C
LAUNDRY
108D
BATHROOM 1
108K
BEDROOM 2
108N
CLOSET 2
108P
BEDROOM 1
108L
CLOSET 1
108M
M. SHOWER
108H
M. BATHROOM
108F
M. BEDROOM
108E
M. CLOSET
108G
UNIT 3
108
FIGURE 304.3.1.1
FIGURE 1103.11.2.4(C)
FIGURE 304.3.2.1
FIGURE 404.2.3.2(H)
FIGURE 1103.11.2.5.1(A)
FI
G
U
R
E
4
0
4
.
2
.
3
.
2
(
F
)
FI
G
U
R
E
6
1
1
.
2
FIGURE 404.2.3.2(B)
FIGURE 404.2.3.2(A)
FIGURE 404.2.3.2(A)
FI
G
U
R
E
3
0
4
.
3
.
2
.
1
(
A
)
WO
R
K
SU
R
F
A
C
E
FI
G
U
R
E
4
0
4
.
2
.
3
.
2
(
F
)
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
3
6
P
M
CR1.5
CODE REVIEW
TYPE A UNIT
FLOOR PLANS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/4" = 1'-0"CR1.5
1 CODE REVIEW 1ST FLOOR UNIT 1 AND 2 PLAN
1/4" = 1'-0"CR1.5
2 CODE REVIEW 1ST FLOOR UNIT 3 PLAN
no. description date
MIN
11"
MI
N
9"
MI
N
27
"
MIN
8"
MI
N
30
"
MAX
25"
FIGURE 306.3(A)
KNEE CLEARANCE -ELEVATION
FIGURE 306.3(B)
KNEE CLEARANCE -PLAN
MI
N
15
"
MA
X
48
"
FIGURE 308.2.1
UNOBSTRUCTED FORWARD REACH
MA
X
48
"
MAX
10"
FIGURE 308.3.2(A)
OBSTRUCTED HIGH SIDE REACH
FIGURE 308.3.2(B)
OBSTRUCTED HIGH SIDE REACH
MA
X
34
"
MAX
> 10"-24"
MA
X
46
"
MAX
20"
48
"
M
A
X
MAX
>20" - 25"
44
"
M
A
X
(A)(B)
FIGURE 308.2.2
OBSTRUCTED HIGH FORWARD REACH
MI
N
15
"
MAX
10"
MA
X
48
"
FIGURE 308.3.1
UNOBSTRUCTED SIDE REACH
15"-16"
FIGURE 610.2(A)
BATHTUB SEATS
REMOVABLE IN-TUB SEATS
FIGURE 610.2(B)
BATHTUB SEATS
SEAT PROVIDED AT HEAD END OF TUB
17
"
-
1
9
"
15" MIN
17
"
-
1
9
"
BACK WALL
CO
N
T
R
O
L
EN
D
W
A
L
L
HE
A
D
E
N
D
WA
L
L
BACK WALL
CO
N
T
R
O
L
EN
D
W
A
L
L
HE
A
D
E
N
D
WA
L
L
52" MIN
30
"
M
I
N
FIGURE 305.3.1
SIZE OF CLEAR FLOOR SPACE -NEW BUILDING
67" MIN10
"
M
A
X
FIGURE 304.3.1.1
CIRCULAR TURNING SPACE -NEW BUILDINGS
SIZE AND OVERLAP
FIGURE 304.3.2.1
T-SHAPED TURNING SPACE -NEW BUILDINGS
MIN
16"36" MIN
MIN
16"
68" MIN
36
"
M
I
N
24
"
M
I
N
60
"
M
I
N
8"
8"
MIN
11"42" MIN
MIN
11"
64" MIN
38
"
M
I
N
22
"
M
I
N
60
"
M
I
N
FIGURE 404.2.3.2(F)
MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS
HINGE APPROACH -PUSH SIDE
* 48" MIN IF BOTH CLOSER AND LATCH PROVIDED42
"
M
I
N
*
22" MIN
FIGURE 404.2.3.2(H)
MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS
LATCH APPROACH -PUSH SIDE
* 48" MIN IF BOTH CLOSER AND LATCH PROVIDED42
"
M
I
N
*
24" MIN
FIGURE 404.2.3.2(A)
MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS
FRONT APPROACH -PULL SIDE
60
"
M
I
N
18" MIN
FIGURE 404.2.3.2(F)
MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS
FRONT APPROACH -PUSH SIDE
* IF BOTH CLOSER AND LATCH PROVIDED52
"
M
I
N
12" MIN*
FIGURE 404.2.3.2(G)
MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS
LATCH APPROACH -PULL SIDE
* 54" MIN IF BOTH CLOSER AND LATCH PROVIDED48
"
M
I
N
*
24" MIN
24"OFFSET 24 INCHES
MAXIMUM FROM CENTER
OF DOOR OPENING
℄
FIGURE 611.2(B)
CLEAR FLOOR SPACE -FRONT LOADING
℄
NOTE:
CABINETRY SHALL BE PERMITTED UNDER THE LAVATORY,
PROVIDED THE FOLLOWING CRITERIA ARE MET:
1. THE CABINETRY CAN BE REMOVED WITHOUT
REMOVAL OR REPLACEMENT OF THE LAVATORY;
2. THE FLOOR FINISH EXTENDS UNDER THE
CABINETRY; AND
3. THE WALLS BEHIND AND SURROUNDING THE
CABINETRY ARE FINISHED.
FIGURE 1103.11.2.4(C)
WATER CLOSETS IN TYPE A UNITS -CLEARANCE WITH
LAVATORY (OVERLAP EXCEPTIONS)
℄
18" MIN
66
"
M
I
N
60" MIN
FIGURE 1103.11.2.5.1(A)
CLEARANCE FOR BATHTUBS IN TYPE A UNITS WITH
REMOVABLE SEATS
BACK WALL
CO
N
T
R
O
L
EN
D
W
A
L
L
HE
A
D
E
N
D
WA
L
L
LENGTH OF BATHTUB AND SEAT12"
30
"
M
I
N
FIGURE 1103.11.2.5.1(A)
CLEARANCE FOR BATHTUBS IN TYPE A UNITS WITH
REMOVABLE SEATS
BACK WALL
CO
N
T
R
O
L
EN
D
W
A
L
L
HE
A
D
E
N
D
WA
L
L
LENGTH OF BATH TUB
30
"
M
I
N
FIGURE 1103.11.2.5.2
STANDARD ROLL-IN TYPE SHOWER COMPARTMENT
IN TYPE A UNITS
BACK WALL
CO
N
T
R
O
L
EN
D
W
A
L
L
HE
A
D
E
N
D
WA
L
L
60" MIN
30
"
M
I
N
NOTE:
LAVATORY PERMITTED PER
SECTION 608.2.2
FIGURE 607.4.1
GRAB BARS FOR BATHTUBS WITH SEAT AT HEAD END OF TUB
BACK WALL
CO
N
T
R
O
L
EN
D
W
A
L
L
HE
A
D
E
N
D
WA
L
L
15" MAX12" MAX
4"
M
A
X
24
"
M
I
N
18
"
M
I
N
3"
-
6
"
SE
C
T
I
O
N
6
0
9
.
4
.
1
33
"
-
3
6
"
8"
-
1
0
"
FIGURE 607.4.2
GRAB BARS FOR BATHTUBS WITH REMOVABLE SEATS
BACK WALL
CO
N
T
R
O
L
EN
D
W
A
L
L
HE
A
D
E
N
D
WA
L
L
24" MIN 24" MAX12" MAX
4"
M
A
X
24
"
M
I
N
18
"
M
I
N
3"
-
6
"
SE
C
T
I
O
N
6
0
9
.
4
.
1
33
"
-
3
6
"
8"
-
1
0
"
MI
N
12
"
FIGURE 1103.12.1.2
U-SHAPED KITCHEN CLEARANCE IN TYPE A UNITS
EXCEPTION
60" MIN
DW
REF
WORK
SURFACE
FIGURE 608.2.3.1
ALTERNATE ROLL-IN-TYPE SHOWER COMPARTMENT SIZE
SEAT WALL
SI
D
E
W
A
L
L
SI
D
E
W
A
L
L
60" MIN
24"-36"
BACK WALL
℄
℄
℄
36
"
M
I
N
FIGURE 608.3.3(A)
GRAB BARS IN ALTERNATE ROLL-
IN-TYPE SHOWER -ELEVATION
SEAT WALL
SI
D
E
W
A
L
L
SI
D
E
W
A
L
L
BACK WALL
6"
M
A
X
OF
S
E
A
T
ED
G
E
6" MAX 6" MAX
SE
C
T
I
O
N
6
0
9
.
4
.
1
33
"
-
3
6
"
6"48"6"
FIGURE 608.3.3(B)
GRAB BARS IN ALTERNATE ROLL-
IN-TYPE SHOWER -PLAN
BACK WALL
FIGURE 608.4.3
ALTERNATE ROLL-IN-TYPE SHOWER CONTROLS AND
HAND SHOWER LOCATION -ELEVATIONS
38
"
M
I
N
16" MIN
SIDE WALL
38
"
M
I
N
15"
BACK WALL
48
"
M
A
X
27" MAX ℄SHOWER SEAT
48
"
M
A
X
FIGURE 608.4.3(A)
END WALL -ELEVATION
FIGURE 608.4.3(B)
CONTROL WALL -ELEVATION
FIGURE 404.2.3.3(D)
MANEUVERING CLEARANCE AT SLIDING AND
FOLDING DOORS -STOP OR LATCH APPROACH
42
"
M
I
N
32" MIN 24" MIN
FIGURE 404.2.3.3(C)
MANEUVERING CLEARANCE AT SLIDING AND
FOLDING DOORS -POCKET OR HINGE APPROACH
42
"
M
I
N
32" MIN22" MIN
48" MIN
30
"
M
I
N
FIGURE 1104.1.1
CLEAR FLOOR SPACE FOR TYPE B UNITS
FIGURE 1104.9
REACH OVER A KITCHEN OR BATHROOM CABINET
(TYPE B UNIT)
36
"
M
A
X
> 10"-25 1/2"
46
"
M
A
X
CLEAR FLOOR SPACE
FIGURE 1104.11.3.1.1
LAVATORY IN TYPE B UNITS -OPTION A BATHROOMS
24" MIN ℄
FIGURE 1104.11.3.1.2(B)
CLEARANCE AT WATER CLOSETS IN TYPE B UNITS
CLEARANCE WIDTH AND DEPTH
℄
16"-18"
48" MIN
56
"
M
I
N
NOTE:
A VANITY OR OTHER OBSTRUCTION 24 INCHES MAXIMUM
IN DEPTH, MEASURED PERPENDICULAR FROM THE REAR
WALL, SHALL BE PERMITTED TO OVERLAP THE REQUIRED
CLEARANCE, PROVIDED THE WIDTH OF THE REMAINING
CLEARANCE AT THE WATER CLOSET IS 33 INCHES
MINIMUM.
FIGURE 1104.11.3.1.2(D)
CLEARANCE AT WATER CLOSETS IN TYPE B UNITS
CLEARANCE WITH LAVATORY OVERLAP
℄
24
"
M
A
X
33" MIN
16"-18"
FIGURE 1104.11.3.1.3.2
FORWARD APPROACH BATHTUB IN TYPE B UNITS
OPTION A BATHROOM
BACK WALL
CO
N
T
R
O
L
EN
D
W
A
L
L
HE
A
D
E
N
D
WA
L
L
60" MIN
48
"
M
I
N
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
3
8
P
M
CR1.6
ICC A117.1-2017
FIGURES
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/4" = 1'-0"CR1.6
4 FIGURE 306.3
1/4" = 1'-0"CR1.6
5 FIGURE 308.2.1
1/4" = 1'-0"CR1.6
8 FIGURE 308.3.2
1/4" = 1'-0"CR1.6
6 FIGURE 308.2.2
1/4" = 1'-0"CR1.6
7 FIGURE 308.3.1
1/4" = 1'-0"CR1.6
20 FIGURE 610.2
1/4" = 1'-0"CR1.6
3 FIGURE 305.3.1
1/4" = 1'-0"CR1.6
1 FIGURE 304.3.1.1
1/4" = 1'-0"CR1.6
2 FIGURE 304.3.2.1
1/4" = 1'-0"CR1.6
11 FIGURE 404.2.3.2(F)
1/4" = 1'-0"CR1.6
13 FIGURE 404.2.3.2(H)
1/4" = 1'-0"CR1.6
9 FIGURE 404.2.3.2(A)
1/4" = 1'-0"CR1.6
10 FIGURE 404.2.3.2(B)
1/4" = 1'-0"CR1.6
12 FIGURE 404.2.3.2(G)
1/4" = 1'-0"CR1.6
21 FIGURE 611.2
1/4" = 1'-0"CR1.6
22 FIGURE 1103.11.2.4(C)
1/4" = 1'-0"CR1.6
23 FIGURE 1103.11.2.5.1
1/4" = 1'-0"CR1.6
24 FIGURE 1103.11.2.5.2
1/4" = 1'-0"CR1.6
15 FIGURE 607.4.1
1/4" = 1'-0"CR1.6
16 FIGURE 607.4.2
1/4" = 1'-0"CR1.6
25 FIGURE 1103.12.1.2
1/4" = 1'-0"CR1.6
17 FIGURE 608.2.3.1
1/4" = 1'-0"CR1.6
18 FIGURE 608.3.3
1/4" = 1'-0"CR1.6
19 FIGURE 608.4.3
1/4" = 1'-0"CR1.6
14 FIGURE 404.2.3.3
1/4" = 1'-0"CR1.6
26 FIGURE 1104.1.1
1/4" = 1'-0"CR1.6
27 FIGURE 1104.9
1/4" = 1'-0"CR1.6
28 FIGURE 1104.11.3.1.1
1/4" = 1'-0"CR1.6
29 FIGURE 1104.11.3.1.2(B)
1/4" = 1'-0"CR1.6
30 FIGURE 1104.11.3.1.2(D)
1/4" = 1'-0"CR1.6
31 FIGURE 1104.11.3.1.3.2
no. description date
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
3
8
P
M
CR1.7
COMCHECK
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
no. description date
UP UP
1
A5.3
________1
A5.3
________
B
B
C
C
D
D
E
E
G
G
1 1
________1
A3.2
________2
A3.1
________1
A3.1
5 5
6 6
10 10
UNIT 2
102
TYPE A
105'-0"
11'-0"27'-0"17'-0"17'-0"27'-0"6'-0"
3 3
F
F
7 7
A
A
105'-0"
2 2
9 9
4 4
________1
A1.4
________2
A1.4
________2
A3.2
78
'
-
0
"
11'-0"27'-0"17'-0"17'-0"27'-0"6'-0"
78
'
-
0
"
4'
-
0
"
29
'
-
6
"
3'
-
0
"
5'
-
0
"
3'
-
0
"
12
'
-
4
"
17
'
-
2
"
4'
-
0
"
4'
-
0
"
29
'
-
6
"
3'
-
0
"
5'
-
0
"
3'
-
0
"
12
'
-
4
"
17
'
-
2
"
4'
-
0
"
UNIT 1
106
TYPE B
UNIT 1
104
TYPE A
UNIT 3
108
TYPE A
UNIT 2
101
TYPE B
UNIT 1
105
TYPE B
UNIT 1
103
TYPE B
UNIT 2
107
TYPE B
1
A5.1
________
1
A5.1
________
2
A5.1
________
2
A5.1
________
8 8
2
A5.3
________2
A5.3
________
1
A5.2
________
1
A5.2
________
2
A5.2
________
2
A5.2
________
2
A5.4
________2
A5.4
________
1
A5.5
________1
A5.5
________
1
A5.4
________1
A5.4
________
________1
A9.1
________4
A9.1
5'-0"2'-6"3'-6"7'-0"4'-6"5'-5"2'-5"8"10"4'-6"1'-8"3'-4"6'-0"4"7'-4"7'-4"4"6'-0"3'-4"1'-8"4'-6"10"8"2'-5"5'-5"4'-6"7'-0"3'-6"2'-6"
WO
R
K
SU
R
F
A
C
E
WO
R
K
SU
R
F
A
C
E
WO
R
K
SU
R
F
A
C
E
WO
R
K
SU
R
F
A
C
E
WO
R
K
SU
R
F
A
C
E
WO
R
K
SU
R
F
A
C
E
WO
R
K
SU
R
F
A
C
E
WO
R
K
SU
R
F
A
C
E
102A
102B
102C
104A104B
102D102K
108A
108B
108C
108D
108K
104C
104D
104F
104E
104G
102E102G
102M102L
104J 102J
104H
102H
102F
108N108P108L
108M
108H108F
108E
108G
106A 106B
106C
106D
106E
106F
106G
106H
106J
101A101B
101C
101D
101E
101F 101H
101G101J
101K
101L
101M
103A103B
103C 103D103F
103E
103H
103G
103J
105A 105B
105C105D
105E
105F
105G
105H
105J
107A
107B
107C107D
107E
107F
107G
107H
107J
107K
107L
107M
033000.60
033000.60
033000.60033000.60
033000.60
033000.60033000.60
033000.60
033000.60
033000.60 033000.60
096466.01
096466.01
096466.01
096466.01
096466.02
096466.02
096466.02096466.02
096466.01
096466.01096466.01
096466.02
096466.01
096466.02
096466.01
096466.02
096466.01
096466.01
096466.01
096466.02
096466.01
096466.02
096466.01
096466.02
096466.01096466.01
096466.01
096466.02
096466.02096466.02
096466.01
096466.01
096466.02
096466.01
096466.02
096466.01
096466.01
105 102
108J
103
101104 E1
102
E2
E3E4
E5
E6
E7
E8
E9
E10 E11
E12
B
BB
BB
B
B
B
K
Ll
M
G
J
Ff
EE
Ff
JJ
EE
Ff
N
K
L
J
P
MFf
G
Ee
K
LEeFf
G
J
EE
Ff
J J
EE
Ff
J G
EeL
K
Ff
105
104 101
Ee
MM
6"
3'-0"3'-0"
E1
E1E2
E2
E2
E2
E1E2
E4
E3
E4
E4
E5
E4
E1
E4
E2
E4E3
E2E1
E1
E1
E1
E2
E3
E4
E2E1
E4E1E4
E4
E5
E2
E2
E4
E3 E2
E1 E2
E1
E1 E2
E3
E2
E1
E4
E4
E1
E4
E4 E1E4
E4
E2
E4 E3
E2 E1
C
CC
C
B
B
B
D C
C C
CE1
E1
E1
E2
E3 E4
E2 E1
E4 E1 E4
E4
E2
E2
W1
W2
W1
W2W2
W2
E2W3
W4W2
W5
W4W2W4W2W4
W2W2
W1W1
W3 W2
W2
W4 W2 W4 W2 W4 W2 W4
W3
W5
W3
W1
W1
W1
W1
W1 W3
W3
W3
W1
W1
W1
W5
W1W3
W1
W3
W1
W3
W5W5
W3W3
W5
W3
W1
W3
W1
W5
W1
W5
W1
W1W1
W1
W3
W3 W3
W1
W1
W1
W1
W3
W3W3
W5W5
W3
W3W1
W1
W1
W5
W1 W1
W1
W3W3
W5W5
W3
W1W3
W1
W3
W1
W3
W5W5
W3
W1 W3
W1
W3
W1
W5
W5W1
W1
W1
W1
W3
W3
W2
W3
W3
W1
220000
230000.01
230000 230000230000 230000
230000230000230000
230000
104416
E1 W1
E4
E5
W2E2
W3
W4
GA FILE NO. WP 3267
1 HOUR FIRE -50 TO 54 STC SOUND
5/8" GYPSUM WALL BOARD
2X FRAMING -SEE
STRUCTURAL DRAWINGS
BATT INSULATION R-21 MIN.
SHEATHING -SEE
STRUCTURAL DRAWINGS
AIR GAP
METAL PANEL SIDING
5/8" GYPSUM WALL BOARD
2X FRAMING -SEE
STRUCTURAL DRAWINGS
BATT INSULATION R-21 MIN.
SHEATHING -SEE
STRUCTURAL DRAWINGS
ENGINEERED WOOD SIDING
5/8" GYPSUM WALL BOARD
2X FRAMING -SEE
STRUCTURAL DRAWINGS
BATT INSULATION R-21 MIN.
SHEATHING -SEE
STRUCTURAL DRAWINGS
EFIS SIDING WITH 2" RIGID
INSULATION
ENGINEERED WOOD SIDING
EACH SIDE
2X FRAMING -SEE
STRUCTURAL DRAWINGS
SHEATHING EACH SIDE -SEE
STRUCTURAL DRAWINGS
5/8" GYPSUM WALL BOARD
EACH SIDE
2X FRAMING -SEE
STRUCTURAL DRAWINGS
FULL THICKNESS BATT
INSULATION
5/8" GYPSUM WALL BOARD
EACH SIDE
2X FRAMING -SEE
STRUCTURAL DRAWINGS
FULL THICKNESS BATT
INSULATION
1/2" RESILIENT CHANNEL
5/8" GYPSUM WALL BOARD
EACH SIDE
2X FRAMING -SEE
STRUCTURAL DRAWINGS
FULL THICKNESS BATT
INSULATION
5/8" GYPSUM WALL BOARD
2X FRAMING -SEE
STRUCTURAL DRAWINGS
FULL THICKNESS BATT
INSULATION
1/2" RESILIENT CHANNEL
5/8" GYPSUM WALL BOARD
E3
5/8" GYPSUM WALL BOARD
2X FRAMING -SEE
STRUCTURAL DRAWINGS
BATT INSULATION R-21 MIN.
SHEATHING -SEE
STRUCTURAL DRAWINGS
STUCCO FINISH
W5
GA FILE NO. WP 3116
1 HOUR FIRE -55 TO 59 STC SOUND
5/8" GYPSUM WALL BOARD
2X FRAMING -SEE
STRUCTURAL DRAWINGS
FULL THICKNESS BATT
INSULATION
2" CONTINUOUS AIR SPACE
5/8" GYPSUM WALL BOARD
GA FILE NO. WP 3247
1 HOUR FIRE
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
4
9
:
0
3
P
M
A1.1
1ST FLOOR PLAN
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1. PROVIDE BACKING PLATES IN STUD WALLS FOR ALL TOILET ACCESSORIES, CASEWORK,
ETC.
2. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
OR STRUCTURAL DRAWINGS, CONTACT ARCHITECT FOR CLARIFICATION.
3. ALL G.W.B. TO BE 5/8" UNLESS NOTED OTHERWISE.
4. USE WATER RESISTANT G.W.B. IN ALL WET AREAS.
5. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIAL, EXCEPT
STONE.
6. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
7. LOCATE DOOR R.O. 3" FROM ADJACENT STUD WALL UNLESS NOTED OTHERWISE.
8. SEE A1 SERIES FOR WALL TYPES
9. SEE SHEET A2.1 FOR ROOM FINISH SCHEDULE.
10. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
11. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
GENERAL NOTES
1/8" = 1'-0"A1.1
1 1ST FLOOR PLAN
KEYED NOTES
033000.60 CONCRETE FLOOR FINISH
096466.01 LAMINATE WOOD FLOORING
096466.02 CARPET FLOORING
104416 FIRE EXTINGUISHER & CABINET
220000 PLUMBING FIXTURE OR EQUIPMENT - SEE PLUMBING
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
230000.01 GAS PIPE COVER - PROVIDE LOCK
WALL TYPES
no. description date
Panic hardware shall be installed as per IBC section
1010.1.10 on required doors.
DN DNUPUP
1
A5.3
________1
A5.3
________
B
B
C
C
D
D
E
E
G
G
1 1
________1
A3.2
________2
A3.1
________1
A3.1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
________2
A3.2
1
A5.1
________
1
A5.1
________
2
A5.1
________
2
A5.1
________
8 8
2
A5.3
________2
A5.3
________
UNIT 2
202
UNIT 1
206
UNIT 1
204
UNIT 3
208
UNIT 2
201
UNIT 1
205
UNIT1
203
UNIT 2
207
________1
A1.5
________2
A1.5
1
A5.2
________
1
A5.2
________
2
A5.2
________
2
A5.2
________
2
A5.4
________2
A5.4
________
1
A5.5
________1
A5.5
________
1
A5.4
________1
A5.4
________
________2
A9.1
________5
A9.1
1
CR1.4
________
1
CR1.4
________
2
CR1.4
________2
CR1.4
________
202A202B
202C 202D
202E
202F
202G
202H
202J
202K
202L
202M
204A204B
204C 204D
204E
204F
204G
204H
204J
208A 208B
208C208D
208E
208F
208G
208H
208J
208K
208L 208M
208N
208P
206A 206B
206C206D
206E
206F
206G
206H
206J
201A201B
201C
201D
201E
201F
201G
201H
201J
201K
203A203B
203C 203D
203E
203F
203G
203H
203J
205A 205B
205C205D
205E
205F
205G
205H
205J
207A 207B
207C207D
207E
207F
207G
207H
207J
207K
207L
207M096466.02
096466.01
096466.02
096466.01
096466.01
096466.01
096466.02
096466.01
096466.01
096466.02
096466.01
096466.01
096466.02
096466.01
096466.02
096466.01
096466.01
033000.60
033000.60033000.60
033000.60
033000.60
033000.60 033000.60
033000.60
033000.60
096466.01
033000.60
096466.01
033000.60
096466.01
096466.02
096466.02
096466.02
096466.01
096466.02
096466.02
096466.01
096466.02 096466.01
096466.02
096466.01
096466.01
096466.01
201L
201M
201
202
203
E13
E14E15
E16
E17
E18
E19 E20
E21
105'-0"
11'-0"27'-0"17'-0"17'-0"27'-0"6'-0"
105'-0"
78
'
-
0
"
11'-0"27'-0"17'-0"17'-0"27'-0"6'-0"
78
'
-
0
"
4'
-
0
"
29
'
-
6
"
3'
-
0
"
5'
-
0
"
3'
-
0
"
12
'
-
4
"
17
'
-
2
"
4'
-
0
"
4'
-
0
"
29
'
-
6
"
3'
-
0
"
5'
-
0
"
3'
-
0
"
12
'
-
4
"
17
'
-
2
"
4'
-
0
"
5'-0"2'-6"3'-6"7'-0"4'-6"5'-4 1/2"2'-5"
8 1/2"10"
4'-6"1'-8"3'-4"6'-0"4"4'-3 1/2"
2'-5"
7 1/2"
7 1/2"
2'-5"4'-3 1/2"4"6'-0"3'-4"1'-8"4'-6"
10"8 1/2"
2'-5"5'-4 1/2"0"4'-6"7'-0"3'-6"2'-6"
201
B
BB
BB
BB
B
203
F
K
L E
G
J
M
EE
JJ
FF
EE
N
J
P
L
M
K
E
F
F
E L
K
G J
M
J
EE
F
J
EE
J
F
L E
K
F
J
G
M
G
A
C
CC
C
A
B
B
B
D C
C C
C
E1
E1E2
E2
E2
E2
E1E2
E4
E3
E4
E4
E1
E2
E4E3
E2E1
E1
E1
E1
E2
E3
E4
E2E1
E1
E4
E2
E2
E4
E3 E2
E1 E2
E1
E1 E2
E3
E2
E1
E4
E4
E1
E4
E1
E4
E2
E4 E3
E2 E1
E1
E1
E1
E2
E3 E4
E2 E1
E1
E4
E2
E2
W2
W1
W2W2
W2
E2W3
W4W2
W5
W4W2W4W2W4
W2W2
W1
W2
W2
W4 W2 W4 W2 W4 W2 W4
W3
W5
W3
W1
W1
W1
W1
W1
W3
W1
W1
W5
W1W1
W3
W1
W3
W5W5
W3W3
W5
W1
W3
W1
W5
W1
W5
W1
W1W1
W1
W3
W3 W3
W1
W1
W1
W3
W3W3
W5W5
W3
W1
W1
W1
W5
W1 W1
W1
W3W3
W5W5
W3
W1W1
W3
W1
W3
W5W5
W3
W1 W1
W3
W1
W5
W5W1
W1
W1
W1
W3
W3
W2
W1
W3
W3 W3
W1 W1
W1 W1
230000 230000230000 230000
230000230000230000230000
5'-4 1/2"4'-6"5'-4 1/2"
104416
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
4
9
:
0
6
P
M
A1.2
2ND FLOOR
PLAN
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"A1.2
1 2ND FLOOR PLAN
1. PROVIDE BACKING PLATES IN STUD WALLS FOR ALL TOILET ACCESSORIES, CASEWORK,
ETC.
2. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
OR STRUCTURAL DRAWINGS, CONTACT ARCHITECT FOR CLARIFICATION.
3. ALL G.W.B. TO BE 5/8" UNLESS NOTED OTHERWISE.
4. USE WATER RESISTANT G.W.B. IN ALL WET AREAS.
5. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIAL, EXCEPT
STONE.
6. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
7. LOCATE DOOR R.O. 3" FROM ADJACENT STUD WALL UNLESS NOTED OTHERWISE.
8. SEE A1 SERIES FOR WALL TYPES
9. SEE SHEET A2.1 FOR ROOM FINISH SCHEDULE.
10. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
11. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
GENERAL NOTES
KEYED NOTES
033000.60 CONCRETE FLOOR FINISH
096466.01 LAMINATE WOOD FLOORING
096466.02 CARPET FLOORING
104416 FIRE EXTINGUISHER & CABINET
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
no. description date
DNDN
1
A5.3
________1
A5.3
________
B
B
C
C
D
D
E
E
G
G
1 1
________1
A3.2
________2
A3.1
________1
A3.1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
________2
A3.2
1
A5.1
________
1
A5.1
________
2
A5.1
________
2
A5.1
________
8 8
2
A5.3
________2
A5.3
________
UNIT 2
302
UNIT 1
306
UNIT 1
304
UNIT 3
308
UNIT 2
301
UNIT 1
305
UNIT 1
303
UNIT 2
307
________1
A1.5
________2
A1.5
1
A5.2
________
1
A5.2
________
2
A5.2
________
2
A5.2
________
2
A5.4
________2
A5.4
________
1
A5.5
________1
A5.5
________
1
A5.4
________1
A5.4
________
2
CR1.4
________2
CR1.4
________
302C 302D 302F
302H
302K
302L 302E
302G
302M
302J
302A302B304A
304C 304D
304E
304G306G306E
306F 304F
304B306B306A
306C306D
304J306J
308N
308J
308P
308M
308L
308G
308C
308D
308K
308E
308F
308A 308B
301A301B
301C 301D301K 301F 301H
301E
301G
301M
301J
301L303E
303G
303J305J
305G
303F305F
303C 303D
303A303B
305C305D
305E
307B
307A
307K
307C307D
307F
307E
307L
307H
307M
307G
307J
096466.02
096466.01
096466.02
096466.01
096466.01
096466.02
096466.01
096466.02
096466.01
096466.02
096466.01
096466.01
096466.02
096466.01
096466.01
033000.60
096466.01
033000.60 033000.60
096466.02
096466.01
096466.02
096466.01
096466.01
096466.02
096466.01
096466.01
096466.02
096466.01
096466.02
096466.01
033000.60
033000.60033000.60
033000.60
033000.60
033000.60 033000.60
305B305A
304H306H
308H
303H305H
301302
303
E22
E23E24
E25
E26
E28 E29
105'-0"
11'-0"27'-0"17'-0"17'-0"27'-0"6'-0"
105'-0"
78
'
-
0
"
11'-0"27'-0"17'-0"17'-0"27'-0"6'-0"
78
'
-
0
"
4'
-
0
"
29
'
-
6
"
3'
-
0
"
5'
-
0
"
3'
-
0
"
12
'
-
4
"
17
'
-
2
"
4'
-
0
"
4'
-
0
"
29
'
-
6
"
3'
-
0
"
5'
-
0
"
3'
-
0
"
12
'
-
4
"
17
'
-
2
"
4'
-
0
"
5'-0"2'-6"3'-6"7'-0"4'-6"5'-4 1/2"2'-5"
8 1/2"
10"4'-6"1'-8"3'-4"6'-0"4"4'-3 1/2"2'-5"7 1/2"
7 1/2"
2'-5"4'-3 1/2"4"6'-0"3'-4"1'-8"4'-6"10"
8 1/2"
2'-5"5'-4 1/2"4'-6"7'-0"3'-6"2'-6"
301
BB
B
B
BB
303
B
F
EE
JJ
EE
F
K
N
L
G
P
M
J
F
EE27
E
F
G
J
M
L
K
EE
F F
JJ
EE
EL
M
G
J
F
K
E30
A
C
CC
C
A
B
B
B
D C
C C
C
E1
E1E2
E2
E2
E2
E1E2
E4
E3
E4
E4
E1
E2
E4E3
E2E1
E1
E1
E1
E2
E3
E4
E2E1
E1
W3
E2
E2
E4
E3 E2
E1 E2
E1
E1 E2
E3
E2
E1
E1
E1
E1
E1
E1
E1
E2
E4 E3
E2 E1
E1
E1
E1
E2
E3 E4
E2 E1
E1
E4
E2
E2
W2
W1
W2W2
W2
E2W3
W4W2
W5
W4W2W4W2W4
W2W2
W1
W2
W2
W4 W2 W4 W2 W4 W2 W4
W3
W5
W3
W1
W1
W1
W1
W1 W3
W3
W1
W1
W5
W1W1
W3
W1
W3
W5W5
W3W3
W5
W1
W3
W1
W5
W1
W5
W1
W1W1W1
W3
W3 W3
W1
W1
W1
W3W3
W5W5
W3
W3W1
W1
W1
W5
W1 W1
W1
W3W3
W5W5
W3
W1W1
W3
W1
W3
W5W5
W3
W1 W1
W3
W1
W5
W5W1W1
W1
W1W3
W3
W2
W3
W1
W3
W1
W1W1
W1 W1
W3
230000 230000230000 230000
230000230000230000230000
104416
G
M
J
EL
K
F
B
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
4
9
:
0
9
P
M
A1.3
3RD FLOOR
PLAN
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"A1.3
1 3RD FLOOR PLAN
1. PROVIDE BACKING PLATES IN STUD WALLS FOR ALL TOILET ACCESSORIES, CASEWORK,
ETC.
2. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
OR STRUCTURAL DRAWINGS, CONTACT ARCHITECT FOR CLARIFICATION.
3. ALL G.W.B. TO BE 5/8" UNLESS NOTED OTHERWISE.
4. USE WATER RESISTANT G.W.B. IN ALL WET AREAS.
5. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIAL, EXCEPT
STONE.
6. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
7. LOCATE DOOR R.O. 3" FROM ADJACENT STUD WALL UNLESS NOTED OTHERWISE.
8. SEE A1 SERIES FOR WALL TYPES
9. SEE SHEET A2.1 FOR ROOM FINISH SCHEDULE.
10. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
11. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
GENERAL NOTES
KEYED NOTES
033000.60 CONCRETE FLOOR FINISH
096466.01 LAMINATE WOOD FLOORING
096466.02 CARPET FLOORING
104416 FIRE EXTINGUISHER & CABINET
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
no. description date
BCD
1
5
3
A
2
4
17'-0"27'-0"6'-0"
50'-0"
36
'
-
6
"
3'
-
0
"
29
'
-
6
"
4'
-
0
"
2'
-
6
1
/
2
"
5
1
/
2
"
12
'
-
4
"
21
'
-
2
"
LIVING
102A
KITCHEN
102B
HALL
102C
LIVING
104A
KITCHEN
104B
LAUNDRY
102D
BATHROOM 1
102K
HALL
104C
LAUNDRY
104D
M. BATHROOM
104F
M. BEDROOM
104E
M. CLOSET
104G
M. BEDROOM
102E
M. CLOSET
102G
CLOSET 1
102M
BEDROOM 1
102L
MECH.
104J
MECH
102J
M. SHOWER
102H
M. BATHROOM
102F
1
A5.1
________
2
A5.3
________
M. SHOWER
104H
UNIT 2
102
TYPE A
UNIT 1
104
TYPE A
2
A5.4
________
1
A5.5
________
1
A5.4
________
4 1/2"1"
1"
3 1/2"
3"2'-5"4'-3 1/2"4"6'-0"3'-4"1'-8"4'-6"10"8"2'-5"5'-5"4'-6"7'-0"
A8.16 8
A8.12
A8.1
30A8.11
2
CR1.4
________
A8.112
A8.1 11A8.1
31
A8.1
15
A8.1 14
A8.1 29
113013.05
123661.19113013.07 224100.02
123661.19
113013.04
123661.19
064116
B
K
Ll Ee
J
G
Ff
M
123530
J
EE
Ff
B
101
123623.33
096466.01
096466.02
096466.01
033000.60
096466.02
096466.01
096466.01
093013.03
230000
224100.04123661.19224100.05
224100.03
096466.02
096466.01
096466.02
096466.01
123530
113013.05
123530123530
093013.03
224100.04
224100.05
123661.19
224100.02
224100.03
113013.01
123661.19
113013.07
064116
123661.19
113013.04
064116
230000230000
123530
1
3
/
4
"
5
1
/
2
"
2'
-
1
"
5
1
/
2
"
12
'
-
4
"
5
1
/
2
"
5'
-
0
1
/
4
"
7
3
/
4
"
7"
2'
-
0
1
/
2
"
2'
-
4
"
3'
-
3
1
/
2
"
3'
-
3
1
/
2
"
3'
-
0
1
/
2
"
5
1
/
2
"
8'
-
8
1
/
4
"
3'
-
7
"
3 1/2"1"
4 1/2"
2'-6 1/4"3'-0"3'-0"7'-9"3 1/2"
1"4 1/2"
10 1/4"3'-0"3'-6"19'-3 1/2"6'-0"
4 1/2"4 1/2"6'-11 1/2"6'-4 1/4"2'-11 1/4"4 1/2"4 1/2"10'-2 1/2"4'-10 1/2"3'-5 1/2"7'-7 1/2"3 1/2"2"3'-0 1/2"5 1/2"2'-6"
1'-5 1/2"
6'
-
4
"
7'
-
8
"
6'
-
8
1
/
2
"
14
'
-
0
"
4'
-
5
1
/
2
"
11
'
-
2
3
/
4
"
5'
-
5
3
/
4
"
11'-1"6'-5 1/2"
2'
-
8
1
/
4
"
2'-10 3/4"6'-0"8'-1 1/2"7'-8 3/4"25'-3 1/2"
16'-3"
2'-0 3/4"3'-5 1/2"1'-5 1/2"9'-3 1/2"9"10'-2 1/2"2'-4 3/4"2'-4 3/4"11'-2"
5'
-
8
1
/
2
"
1'
-
0
"
14
'
-
5
1
/
2
"
5'-6"10'-9"
14
'
-
1
0
1
/
2
"
4'
-
8
1
/
2
"
3
1
/
2
"
2'
-
7
1
/
4
"
3'
-
4
3
/
4
"
2'
-
6
1
/
4
"
3'
-
2
1
/
4
"
5
1
/
2
"
3'
-
6
1
/
2
"
5
1
/
2
"
11
'
-
8
1
/
2
"
50'-0"
7'
-
7
1
/
4
"
15
'
-
4
"
11
'
-
0
"
5'
-
1
0
1
/
2
"
4'
-
3
1
/
2
"
36
'
-
6
"
123530
123530
E12
C
CD
E2
E4
E3
E2
E1E2W2
W3
W3
W3
W1
W3 W1
W1
W1
W5
W1
W1 W1
W5
W4
W2
W2W4W2
W5W5
W3 W3
W1W3
W1
W3
W3W5W5
W5
W5
E4
E4E1E4
E1
E2
E4
E3
E2
E1
E1 230000230000
104416
EG
1
5
3
F
2
4
38'-0"
11'-0"27'-0"
36
'
-
6
"
3'
-
0
"
12
'
-
4
"
17
'
-
2
"
4'
-
0
"
2'
-
6
1
/
2
"
5
1
/
2
"
2'
-
5
1
/
2
"
6'
-
0
"
4'
-
7
"
3'
-
0
"
7'
-
3
"
3'
-
0
"
1'
-
1
0
"
3'
-
0
"
2'
-
4
1
/
2
"
LIVING
108A KITCHEN
108B
HALL
108C
LAUNDRY
108D
BATHROOM 1
108K
BEDROOM 2
108N
CLOSET 2
108P
BEDROOM 1
108L
CLOSET 1
108M
M. SHOWER
108H
M. BATHROOM
108F
M. BEDROOM
108E
2
A5.1
________
2
A5.3
________
M. CLOSET
108G
UNIT 3
108
1
A5.2
________2
A5.2
________
2
A5.4
________
1
A5.5
________
1
A5.4
________
3'-4"6'-0"6'-8"4'-6"7'-5"2'-5"8"10"4'-6"1'-8"
1"4 1/2"
1
CR1.4
________
2
CR1.4
________
A8.13
A8.1 68
A8.1
30
A8.1 29
B
K
N
P
J
M
L
G
Ff
EeE9
113013.07123661.19
224100.02
064116
224100.03
123661.19
113013.04
123661.19
064116
123623.33
096466.01
096466.01
123530
113013.05
096466.01
123530
096466.02
230000
096466.02
096466.02
096466.01
093013.03
033000.60
033000.60
230000
240000
123530
123530123530
224100.04
224100.05
123661.19
123661.19
224100.04
224100.01
A8.1
16
A8.1
31
1
3
/
4
"
5
1
/
2
"
2'
-
1
"
5
1
/
2
"
12
'
-
4
"
5'
-
5
3
/
4
"
7
3
/
4
"
4'
-
3
1
/
2
"
6'
-
3
1
/
2
"
4'
-
0
"
5
1
/
2
"
10
'
-
3
1
/
2
"
11
'
-
2
3
/
4
"
2'
-
6
1
/
2
"
6'
-
1
1
/
2
"
4'
-
3
1
/
2
"
3'
-
7
"
1'
-
2
"
5'
-
6
1
/
2
"
6'
-
8
1
/
2
"
14
'
-
0
"
3'-9"2'-3"5 1/2"4'-6"9'-0"3'-4 1/2"4'-4 1/2"9'-11"4 1/2"4 1/2"
6'-5 1/2"31'-2"
19'-6"
12'-8"6'-3 1/2"6 1/2"
7'-2"2'-1 1/2"3'-4 1/2"6'-3 1/2"3'-6"2'-4 3/4"2'-4 3/4"9'-11"
12'-8"
12'-2 1/4"5'-8 1/4"
15
'
-
4
"
4'
-
8
1
/
2
"
9
1
/
4
"
11
'
-
8
1
/
4
"
4'
-
0
"
36
'
-
6
"
9'-9 1/2"
30'-3 1/2"5 1/2"2'-11 3/4"3'-0 1/4"
1'-2 1/4"
1"4 1/2"
30'-9"7'-3 1/4"
38'-0"
104
C
CD
B
B
B
W5W5
W1
W1
W1
W1
W1W1
W1
W1
W1
W3
W1
W1 W1
W1
W1
W3W3
W2 W2 W4 W5W5
E1 E2
E3
E2
E1
E4
E1
E4
E4
E4
E4 E1 E4E1
E4
E2
E4
E3
E2
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
4
9
:
1
2
P
M
A1.4
1ST FLOOR UNIT
PLANS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/4" = 1'-0"A1.4
1 1ST FLOOR UNIT 1 AND 2 PLAN
1/4" = 1'-0"A1.4
2 1ST FLOOR UNIT 3 PLAN
1. PROVIDE BACKING PLATES IN STUD WALLS FOR ALL TOILET ACCESSORIES, CASEWORK,
ETC.
2. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
OR STRUCTURAL DRAWINGS, CONTACT ARCHITECT FOR CLARIFICATION.
3. ALL G.W.B. TO BE 5/8" UNLESS NOTED OTHERWISE.
4. USE WATER RESISTANT G.W.B. IN ALL WET AREAS.
5. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIAL, EXCEPT
STONE.
6. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
7. LOCATE DOOR R.O. 3" FROM ADJACENT STUD WALL UNLESS NOTED OTHERWISE.
8. SEE A1 SERIES FOR WALL TYPES
9. SEE SHEET A2.1 FOR ROOM FINISH SCHEDULE.
10. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
11. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
GENERAL NOTESKEYED NOTES
033000.60 CONCRETE FLOOR FINISH
064116 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
093013.03 CERAMIC TILING - SHOWER TILE
096466.01 LAMINATE WOOD FLOORING
096466.02 CARPET FLOORING
104416 FIRE EXTINGUISHER & CABINET
113013.01 RESIDENTIAL APPLIANCES - DISHWASHER
113013.04 RESIDENTIAL APPLIANCES - OVEN WITH STOVETOP - CONTROLLS TO BE LOCATED
IN FRONT OF STOVE TOP
113013.05 RESIDENTIAL APPLIANCES - WASHER DRYER COMBO
113013.07 RESIDENTIAL APPLIANCES - REFRIDGERATOR
123530 RESIDENTIAL CASEWORK
123623.33 WOOD COUNTERTOP MATERIAL - MOUNTED AND SUPPORTED AT BENCH HEIGHT
123661.19 QUARTS AGGLOMERATE COUNTERTOPS
224100.01 RESIDENTIAL PLUMBING FIXTURES - TUB
224100.02 RESIDENTIAL PLUMBING FIXTURES - KITCHEN SINK
224100.03 RESIDENTIAL PLUMBING FIXTURES - KITCHEN FAUCET
224100.04 RESIDENTIAL PLUMBING FIXTURES - BATHROOM SINK
224100.05 RESIDENTIAL PLUMBING FIXTURES - BATHROOM FAUCET
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
240000 PLUMBING FIXTURE OR EQUIPMENT - SEE PLUMBING
no. description date
BCD
1
5
3
A
2
4
1
A5.1
________
UNIT 2
202
UNIT 1
204
LIVING
202AKITCHEN
202B
HALL
202C
LAUNDRY
202D
M. BEDROOM
202E
M. BATHROOM
202F
M. CLOSET
202G
M. SHOWER
202H
MECH
202J
BATHROOM 1
202K
BEDROOM 1
202L CLOSET 1
202M
LIVING
204AKITCHEN
204B
HALL
204C
LAUNDRY
204D
M. BEDROOM
204E
M. BATHROOM
204F
M. CLOSET
204G
M. SHOWER
204H
MECH
204J
2
A5.4
________
1
A5.5
________
1
A5.4
________
A8.122 23
A8.19 2
CR1.4
________
A8.117
A8.1
16
A8.1
25
A8.1 29
A8.112
A8.1
31
113013.07 123661.19064116
224100.02
123661.19
224100.03
113013.04
113013.01
123661.19
064116
123623.33
096466.01
096466.01
096466.02
096466.01
096466.02
F
E
G
J
M
L
K
EE
F
J
B B
123530123530
240000
230000
230000
123530
096466.01
096466.01
113013.07
064116
113013.01
123661.19
224100.02
224100.03
123661.19
113013.04
123661.19
123530
123530
230000
123530
240000
230000
224100.04
123661.19
066113.10
224100.05
066113.10
123661.19
224100.04
224100.05
123530A8.1 4
A8.1 10
113013.06
123530
5
1
/
2
"
3'
-
0
1
/
2
"
3'
-
3
1
/
2
"
3'
-
3
1
/
2
"
2'
-
4
"
2'
-
7
1
/
2
"
7
3
/
4
"
5'
-
5
3
/
4
"
12
'
-
9
1
/
2
"
2'
-
1
"
5
1
/
2
"
1
3
/
4
"
6'
-
4
"
8'
-
3
"
6'
-
1
1
/
2
"
15
'
-
2
3
/
4
"
2'
-
8
1
/
4
"
4'
-
5
1
/
2
"
11
'
-
2
3
/
4
"
5'
-
5
3
/
4
"
5'-3 3/4"1'-7 3/4"9'-3 1/2"9"10'-2 1/2"2'-4 3/4"2'-4 3/4"11'-2"
15
'
-
4
"
11
'
-
0
"
5'
-
1
0
1
/
2
"
4'
-
3
1
/
2
"
14
'
-
1
0
1
/
2
"
4'
-
8
1
/
2
"
3
1
/
2
"
6'
-
0
"
2'
-
6
1
/
4
"
3'
-
2
1
/
4
"
5
1
/
2
"
3'
-
6
1
/
2
"
5
1
/
2
"
11
'
-
8
1
/
2
"
36
'
-
6
"
3 1/2"1"
4 1/2"
2'-6 1/4"3'-0"3'-0"7'-9"3 1/2"
1"4 1/2"
10 1/4"3'-0"3'-6"19'-3 1/2"6'-0"
2'-10 3/4"6'-0"8'-1 1/2"7'-8 3/4"25'-3 1/2"
50'-0"
4 1/2"4 1/2"5'-3 3/4"8'-0"2'-11 1/4"4 1/2"4 1/2"10'-2 1/2"4'-10 1/2"3'-5 1/2"7'-7 1/2"5 1/2"3'-6"2'-6"
4'-11 1/2"5'-11 3/4"
10'-11 1/4"
17'-0"27'-0"6'-0"
50'-0"
36
'
-
6
"
3'
-
0
"
29
'
-
6
"
4'
-
0
"
2'
-
9
1
/
4
"
2
3
/
4
"
12
'
-
4
"
21
'
-
2
"
1"
3 1/2"
3"2'-5"4'-3 1/2"4"6'-0"3'-4"1'-8"4'-6"10"
8 1/2"
2'-5"5'-4 1/2"4'-6"7'-0"
5'
-
8
1
/
2
"
1'
-
0
"
14
'
-
5
1
/
2
"
11'-1"6'-5 1/2"
8'
-
9
1
/
2
"
3'
-
6
1
/
2
"
E21
C
CD
E4
E3
E2
E1E2W2
W3
W1
W3 W1
W1
W1
W5
W1
W1 W1
W5
W4
W2
W2W4W2
W5W5
W3 W3
W1W1
W3
W3
W3W5W5
W5
W5
E4
E1
E2
E3
E2
E1
E1 E1 E4
E2
E2
E4
W3
230000230000
104416
EG
1
5
3
F
2
4
2
A5.3
________
A8.1
UNIT 3
208
LIVING
208A
KITCHEN
208B
HALL
208C
LAUNDRY
208D
M. BEDROOM
208E
M. BATHROOM
208F
M. CLOSET
208G
M. SHOWER
208H MECH
208J
BATHROOM 1
208K
BEDROOM 1
208L
CLOSET 1
208M
BEDROOM 2
208N
CLOSET 2
208P
1
A5.2
________2
A5.2
________
2
A5.4
________
1
A5.5
________
1
A5.4
________
1
CR1.4
________
2
CR1.4
________
13
A8.17
A8.1 29
066113.10
224100.04
123661.19
224100.05
096466.01
096466.02
123530123530
G
EE18
F
L
N
K
J
B
203
096466.02
096466.01
096466.02
096466.01
M
123530
P
230000
240000
230000
123530
224100.01123661.19
224100.04 224100.05
113013.07123661.19 064116
224100.02
123661.19
224100.03
113013.04
113013.01
123661.19
064116
123623.33
123530
A8.1
16
A8.1
31
A8.123 22
38'-0"
11'-0"27'-0"
36
'
-
6
"
3'
-
0
"
12
'
-
4
"
17
'
-
2
"
4'
-
0
"
2'
-
6
1
/
2
"
5
1
/
2
"
2'
-
5
1
/
2
"
6'
-
0
"
4'
-
7
1
/
2
"
3'
-
0
"
7'
-
2
1
/
2
"
3'
-
0
"
3'-4"6'-0"6'-8"4'-6"7'-3"2'-8"7"10"4'-6"1'-8"
1
3
/
4
"
5
1
/
2
"
2'
-
1
"
5
1
/
2
"
12
'
-
4
"
5'
-
5
3
/
4
"
7
3
/
4
"
4'
-
5
1
/
4
"
6'
-
1
3
/
4
"
4'
-
0
"
5
1
/
2
"
2'
-
6
1
/
2
"
15
'
-
4
"
4'
-
8
1
/
2
"
9
1
/
4
"
11
'
-
8
1
/
4
"
4'
-
0
"
36
'
-
6
"
30'-2 3/4"6 1/4"2'-11 3/4"3'-0 1/4"
1'-2 1/4"
1"4 1/2"
30'-9"7'-3 1/4"
38'-0"
3'-9"2'-3"5 1/2"4'-6"9'-0"3'-4 1/2"4'-4 1/2"9'-11"4 1/2"4 1/2"
6'-5 1/2"31'-2"
11
'
-
2
3
/
4
"
7'-2"5'-6"6'-3 1/2"3'-6"2'-4 3/4"2'-4 3/4"9'-11"
12'-8"
9'-9 1/2"
11'-10 3/4"
6'
-
1
1
/
2
"
4'
-
3
1
/
2
"
4'
-
1
1
3
/
4
"
5'
-
3
3
/
4
"
2'
-
1
3
/
4
"
3'
-
0
"
2'
-
1
"
A
B
B
B
D C
C
E17
W5W5
W1
W1
W1
W1
W1W1
W1
W1
W1
W3
W1
W1 W1
W1
W1
W3W3
W2 W2 W4 W5W5
E2
E3
E2
E1
E4
E1
E4
E4
E1 E1
E4
E3
E3
E2E2
E4
E1
230000
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
4
9
:
1
5
P
M
A1.5
2ND & 3RD
FLOOR UNIT
PLANS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1. PROVIDE BACKING PLATES IN STUD WALLS FOR ALL TOILET ACCESSORIES, CASEWORK,
ETC.
2. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
OR STRUCTURAL DRAWINGS, CONTACT ARCHITECT FOR CLARIFICATION.
3. ALL G.W.B. TO BE 5/8" UNLESS NOTED OTHERWISE.
4. USE WATER RESISTANT G.W.B. IN ALL WET AREAS.
5. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIAL, EXCEPT
STONE.
6. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
7. LOCATE DOOR R.O. 3" FROM ADJACENT STUD WALL UNLESS NOTED OTHERWISE.
8. SEE A1 SERIES FOR WALL TYPES
9. SEE SHEET A2.1 FOR ROOM FINISH SCHEDULE.
10. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
11. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
GENERAL NOTES
1/4" = 1'-0"A1.5
1 2ND & 3RD FLOOR UNIT 1 AND 2 PLAN
1/4" = 1'-0"A1.5
2 2ND & 3RD FLOOR UNIT 3 PLAN
KEYED NOTES
064116 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
066113.10 FIBERGLASS REINFORCED ACRYLIC/ABS - SHOWER BASE
096466.01 LAMINATE WOOD FLOORING
096466.02 CARPET FLOORING
104416 FIRE EXTINGUISHER & CABINET
113013.01 RESIDENTIAL APPLIANCES - DISHWASHER
113013.04 RESIDENTIAL APPLIANCES - OVEN WITH STOVETOP - CONTROLLS TO BE LOCATED
IN FRONT OF STOVE TOP
113013.06 RESIDENTIAL APPLIANCES - WASHER AND DRYER STACKABLE UNIT
113013.07 RESIDENTIAL APPLIANCES - REFRIDGERATOR
123530 RESIDENTIAL CASEWORK
123623.33 WOOD COUNTERTOP MATERIAL - MOUNTED AND SUPPORTED AT BENCH HEIGHT
123661.19 QUARTS AGGLOMERATE COUNTERTOPS
224100.01 RESIDENTIAL PLUMBING FIXTURES - TUB
224100.02 RESIDENTIAL PLUMBING FIXTURES - KITCHEN SINK
224100.03 RESIDENTIAL PLUMBING FIXTURES - KITCHEN FAUCET
224100.04 RESIDENTIAL PLUMBING FIXTURES - BATHROOM SINK
224100.05 RESIDENTIAL PLUMBING FIXTURES - BATHROOM FAUCET
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
240000 PLUMBING FIXTURE OR EQUIPMENT - SEE PLUMBING no. description date
UP UPFS
TS
DN DN
F/L
F F/LF
F/L
F
F
7,154 SF
OVERALL GROSS 1ST
FLOOR AREA
7,024 SF
OVERALL GROSS 2ND
FLOOR AREA
17'-0"
926 SF
2 BEDROOM UNIT
578 SF
1 BEDROOM UNIT
1,198 SF
3 BEDROOM UNIT
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
4
9
:
1
9
P
M
A2.1
AREA PLANS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
SQUARE FOOTAGE CALCULATIONS
GROSS AREAS
OVERALL GROSS 1ST FLOOR AREA 7,154 SF
OVERALL GROSS 2ND FLOOR AREA 7,024 SF
OVERALL GROSS 3RD FLOOR AREA 7,024 SF
TOTAL HABITABLE 21,202 SF
1/8" = 1'-0"A2.1
1 1ST FLOOR OVERALL AREA PLAN
1.GROSS BUILDING AREAS ARE MEASURED FROM EXTERIOR FACE OF FRAMING.
2.UNIT AREAS ARE MEASURED FROM EXTERIOR FACE OF FRAMING OF EXTERIOR WALLS AND CENTER
LINE OF INTERIOR WALLS.
3.2ND AND 3RD FLOORS ARE IDENTICAL.
1/8" = 1'-0"A2.1
2 2ND AND 3RD FLOOR OVERALL AREA PLANS
1/8" = 1'-0"A2.1
3 1ST FLOOR UNIT 1 AND 2 AREA PLAN
1/8" = 1'-0"A2.1
4 1ST FLOOR UNIT 3 AREA PLAN
UNIT AREAS
1 BEDROOM UNIT 578 SF
2 BEDROOM UNIT 926 SF
3 BEDROOM UNIT 1,198 SF
no. description date
3/4"
3
1
/
2
"
A - RUNNING
BASE TRIM
B - SILL TRIM C - HEAD TRIM
3/
4
"
3
1
/
2
"
3/4"1/2"3/4"
5
1
/
2
"
D - STANDING
TRIM
3/4"
3
1
/
2
"
EASED
EDGE
EASED
EDGE
EASED
EDGE
EASED
EDGE
TRIM TO BE SANDED AND PAINTED MEDIUM DENSITY FIBERBOARD (MDF)INTERIOR TRIM
1X
1X4
1X6
1X4
1X6
1X4
1X4
A
B
DOUBLE STUDS @ JAMBS SILL BELOW
& HEAD ABOVE
TYP. HEADER
CONSTRUCTION -SEE
STRUCTURAL DRAWINGS
FASTEN HEADER TO STUDS
DOUBLE STUDS
AT JAMBS
TRIPPLE JOIST
HEADER -SEE
SCHEDULE BELOW
CONTINUOUS DEFLECTION
STUD
SECTION A SECTION B
DOUBLE 2X WOOD BLOCKING
FOR WALL CABINETS, GRAB
BARS AND LARGER ITEMS
SINGLE 2X6 WOOD BLOCKING FOR
ALL MOUNTED TOILET
ACCESSORIES, LOWER CASEWORK
AND SMALLER ITEMS
PLYWOOD TOP
2X FRAMED LEGS
2X BRACING
LEGS EVERY 2' O.C
NOTE:
BLOCKOUT NEEDS TO BE CONSTRUCTED IN A WAY
TO WITHSTAND 200LB FORCES FROM THE FURNACE
REINFORCED
LEGS IN THE
CORNERS
APPLY CROSS
BRACING IF
NECESSARY
CA
B
.
H
T
.
CA
B
.
H
T
.
CA
B
.
H
T
.
1
1
/
2
"
CL
1
1
/
2
"
1
1
/
2
"
CL
CL
1
1
/
2
"
CL
SEE DETAIL 3/A2.1
FOR BACKING PLATES
WITHIN WALL
INSTALL BASE AT
CABINETS -SEE
RM. FINISH SCHED.
WALL CABINET -
SEE INT. ELEV.
SEE DETAIL 3/A2.1
FOR BACKING PLATES
WITHIN WALL
BASE CABINET -
SEE INT. ELEV.
INSTALL BASE AT
CABINETS -SEE
RM. FINISH SCHED.
NUMBER NAME FLOOR BASE
WALLS CEILING
REMARKSNORTH EAST SOUTH WEST FINISH HEIGHT (+/-)
CORE
101 1ST FLOOR STAIR A F3 B1 W3 W3 W3 W3 C1 8'-11 3/8"
102 IT F3 B1 W3 W3 W3 W3 C1 8'-11 3/8"
103 1ST FLOOR COORIDOR F3 B1 W3 W3 W3 W3 C1 8'-11 3/8"
104 1ST FLOOR STAIR B F3 B1 W3 W3 W3 W3 C1 8'-11 3/8"
105 JANITOR F3 B1 W3 W3 W3 W3 C1 8'-11 3/8"
201 2ND FLOOR STAIR A F3 B1 W3 W3 W3 W3 C1 8'-11 3/8"
202 2ND FLOOR CORRIDOR F3 B1 W3 W3 W3 W3 C1 8'-11 3/8"
301 3RD FLOOR STAIR A F3 B1 W3 W3 W3 W3 C1 8'-11 3/8"
302 3RD FLOOR CORRIDOR F3 B1 W3 W3 W3 W3 C1 8'-11 3/8"
303 3RD FLOOR STAIR B F3 B1 W3 W3 W3 W3 C1 8'-11 3/8"
UNIT 102 - TYPICAL UNIT 2
102A LIVING F1 B1 W1 W1 W1 - C1 8'-11 3/8"
102B KITCHEN F1 B1 W1 - W1 W1, W2 C1 8'-11 3/8"
102C HALL F1 B1 - W1 W1 W1 C1 8'-11 3/8"
102D LAUNDRY F1 B1 W1 W1 W1 - C1 8'-11 3/8"
102E M. BEDROOM F4 B1 W1 W1 W1 W1 C1 8'-11 3/8"
102F M. BATHROOM F1 B2 W1 - W1 W1 C1 8'-11 3/8"
102G M. CLOSET F4 B1 W1 W1 W1 W1 C1 8'-11 3/8"
102H M. SHOWER F2 B2 W2 W2 W2 W2 C1 8'-11 3/8"
102J MECH F3 B1 W1 W1 W1 W1 C1 8'-11 3/8"
102K BATHROOM 1 F1 B2 W1 W1 W1 - C1 8'-11 3/8"
102L BEDROOM 1 F4 B1 W1 W1 W1 W1 C1 8'-11 3/8"
102M CLOSET 1 F4 B1 W1 W1 W1 W1 C1 8'-11 3/8"
UNIT 104 - TYPICAL UNIT 1
104A LIVING F1 B1 W1 W1 W1 - C1 8'-11 3/8"
104B KITCHEN F1 B1 W1 - W1 W1, W2 C1 8'-11 3/8"
104C HALL F1 B1 - W1 W1 W1 C1 8'-11 3/8"
104D LAUNDRY F1 B1 W1 W1 W1 - C1 8'-11 3/8"
104E M. BEDROOM F4 B1 W1 W1 W1 W1 C1 8'-11 3/8"
104F M. BATHROOM F1 B2 W1 W1 W1 W1 C1 8'-11 3/8"
104G M. CLOSET F4 B1 W1 W1 W1 W1 C1 8'-11 3/8"
104H M. SHOWER F2 B2 W2 W2 W2 W2 C1 8'-11 3/8"
104J MECH. F3 B1 W1 W1 W1 W1 C1 8'-11 3/8"
UNIT 108 - TYPICAL UNIT 3
108A LIVING F1 B1 W1 - W1 W1 C1 8'-11 3/8"
108B KITCHEN F1 B1 W1 W1, W2 W1 - C1 8'-11 3/8"
108C HALL F1 B1 W1 W1 W1 W1 C1 8'-11 3/8"
108D LAUNDRY F1 B1 W1 - W1 W1 C1 8'-11 3/8"
108E M. BEDROOM F4 B1 W1 W1 W1 W1 C1 8'-11 3/8"
108F M. BATHROOM F1 B2 W1 W1 W1 W1 C1 8'-11 3/8"
108G M. CLOSET F4 B1 W1 W1 W1 W1 C1 8'-11 3/8"
FLOOR
F1 RESILIENT PLANK FLOORING
F2 CERAMIC TILE
F3 SEALED CONCRETE
F4 CARPET
BASE
B1 4" PAINTED MDF
B2 PROFILED RESILIENT WALL BASE
WALL
W1 PAINTED, TEXTURED TYPE 'X' GYPSUM BOARD
W2 CERAMIC TILE OVER BACKER BOARD
W3 STUCCO FINISH OVER TYPE 'X' GYPSUM SHEATHING
CEILING
C1 PAINTED, TEXTURED TYPE 'X' GYPSUM BOARD
1. PROVIDE DESIGNATED BASE AROUND BOTTOM OF CABINETS, UNLESS OTHERWISE
NOTED.
2. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
3. SEE A8 SERIES FOR INTERIOR ELEVATIONS FOR TRIM, CASEWORK, TOILET ACCESSORIES, ETC.
4. PROVIDE FLOOR FILLER AS REQUIRED TO PREPARE SLABS FOR FINISH FLOORING.
5. USE WATER RESISTANT G.W.B. IN ALL WET AREAS INDICATED TO RECIEVE G.W.B. -
JANITOR AREAS & TOILET ROOMS @ FIXTURE WALLS ONLY.
6. PROVIDE IN-WALL BLOCKING/BACKING FOR WALL MOUNTED ITEMS - SEE DETAIL 3/A2.1.
7. PROVIDE BACKER BOARD BEHIND ALL TILE WALL FINISHES - DELETE G.W.B.
GENERAL NOTESROOM FINISH LEGENDROOM FINISH SCHEDULE
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
0
0
:
2
9
P
M
A2.2
BUILDING
DETAILS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
3" = 1'-0"A2.2
2 TRIM - INTERIOR DETAILS
1/4" = 1'-0"A2.2
1 TRIM - INTERIOR ELEVATION
NOT TO SCALEA2.2
4 TYPICAL WOOD STUD DETAIL (NON-LOAD BEARING)
NOT TO SCALEA2.2
3 WOOD STUD BACKING DETAIL
NOT TO SCALEA2.2
6 FURNACE PLATFORM DETAIL
NOT TO SCALEA2.2
5 CABINET SECTION @ WOOD STUD WALL
no. description date
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
BCDEG
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. PARAPET 3
ELEV.37' -0"
F A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
1
A5.1
________2
A5.1
________
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
1
A5.2
________2
A5.2
________1
CR1.4
________
C
C
C
D
D
D
C
C
C
E10
E19
E28 E23
E20
E11
C
C
C C
C
C
074213
072413
074213
072413
074213
072413
230000
230000
230000074643.13
072413
074643.13
074643.13
074643.13
074643.13
074643.13
230000
074213
230000
074213
230000
074213
230000
230000
230000
074643.13
074643.13
074643.13
074643.13
074643.13
074643.13
230000
074213
072413
230000
074213
072413
230000
074213
072413
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
1
A5.3
________
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
1
T.O. PARAPET 3
ELEV.37' -0"
5610 37
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
29482
A5.3
________
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
2
A5.4
________1
A5.5
________1
A5.4
________2
CR1.4
________1
A6.1
________
E25
E16
E5 E8E7
E17
E26
B
B
B B B
BB
B B
A
A
074213
072413
072413
072413
074213
074213
072413
072413
074643.13
074643.13
074643.13
074213
074643.13
074213
074643.13
074213
074643.13
072413
074643.13
072413
077253.01
101419
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
4
9
:
3
4
P
M
A3.1
EXTERIOR
ELEVATIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"A3.1
2 SOUTH ELEVATION
1/8" = 1'-0"A3.1
1 WEST ELEVATION
1. SEE A6 SERIES FOR WALL SECTIONS.
2. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
3. ALL VAPOR BARRIERS MUST BE SEALED OR TAPED AT ALL PENETRATIONS & OPENINGS.
4. COORDINATE THE INSTALLATION OF ALL MATERIALS WITH OTHER TRADES.
GENERAL NOTES
KEYED NOTES
072413 EXTERIOR INSULATION FINISH SYSTEM (EIFS) - DRYVIT OUTSULATION SYSTEM - OR
EQUIL
074213 METAL WALL PANELS
074643.13 ENGINEERED WOOD SIDING
077253.01 STANDING SEAM METAL ROOF
101419 DIMENSIONAL LETTER SIGNAGE
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
no. description date
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
1
A5.3
________
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
1
T.O. PARAPET 3
ELEV.37' -0"
5 6 1037
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
2 9482
A5.3
________
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
2
A5.4
________1
A5.5
________1
A5.4
________2
CR1.4
________1
A6.1
________
35'-8"
E30
E21
E12 E2
E13
E22
E1
A
A
101419
077253.01
072413
074643.13
074643.13
074643.13
074643.13
074643.13
074643.13
072413
074213
074643.13
074213
074643.13 074213
074643.13
072413
074643.13
072413
074643.13
072413
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
B C D E G
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. PARAPET 3
ELEV.37' -0"
FA
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
1
A5.1
________2
A5.1
________
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
1
A5.2
________2
A5.2
________1
CR1.4
________
C
C
C C
C
C
E23
E14
E3 E4
E15
E24
C
C
C C
C
C
E6
074213
072413
074643.13
260000
072413
074213
072413
074213
230000
230000
072413
074213
230000074643.13
074643.13
074643.13
074643.13
074643.13
074643.13
072413
074213
230000230000
230000230000
072413
074213
074643.13
074643.13
074643.13
074643.13
074643.13
074643.13
230000
074213
072413
230000
074213
072413
230000
074213
072413077253.01
074643.13
072413
230000230000
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
4
9
:
4
9
P
M
A3.2
EXTERIOR
ELEVATIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"A3.2
1 EAST ELEVATION
1/8" = 1'-0"A3.2
2 NORTH ELEVATION
1. SEE A6 SERIES FOR WALL SECTIONS.
2. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
3. ALL VAPOR BARRIERS MUST BE SEALED OR TAPED AT ALL PENETRATIONS & OPENINGS.
4. COORDINATE THE INSTALLATION OF ALL MATERIALS WITH OTHER TRADES.
GENERAL NOTES
KEYED NOTES
072413 EXTERIOR INSULATION FINISH SYSTEM (EIFS) - DRYVIT OUTSULATION SYSTEM - OR
EQUIL
074213 METAL WALL PANELS
074643.13 ENGINEERED WOOD SIDING
077253.01 STANDING SEAM METAL ROOF
101419 DIMENSIONAL LETTER SIGNAGE
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
260000 ELECTRICAL FIXTURE OR EQUIPMENT - SEE ELECTRICAL
no. description date
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
0
:
2
3
P
M
A3.3
EXTERIOR
PERSPECTIVES
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
A3.3
3 NORTHWEST PERSPECTIVE
A3.3
1 SOUTH PERSPECTIVE
A3.3
2 SOUTHWEST PERSPECTIVE
A3.3
4 WEST PERSPECTIVE
A3.3
5 NORTHEAST PERSPECTIVE
A3.3
6 NORTHWEST BIRDSEYE
no. description date
.ROOF SLOPE / CRICKET
SLOPE
ROOF ACESS HATCH
ROOF DRAIN /
OVERFLOW DRAIN
1
A5.3
________1
A5.3
________
B
B
C
C
D
D
E
E
G
G
1 1
________1
A3.2
________2
A3.1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
1
A5.1
________2
A5.1
________
8 8
2
A5.3
________
1
A5.2
________2
A5.2
________
2
A5.4
________
1
A5.5
________
1
A5.4
________
2
CR1.4
________
077253.02077253.02
077253.02077253.02
077253.02077253.02
077253.02077253.02
37
'
-
9
"
EQ EQ
1/
4
"
/
1
2
"
2'-6"
5'-0"
2'-6"
3'-6"
4'
-
0
"
4'
-
0
"
3'
-
1
1
1
/
2
"
4'
-
0
"
4'
-
0
"
1/
4
"
/
1
2
"
5/8" / 12"
37
'
-
9
"
1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"5/8" / 12"
075419
075419
075419
075419
077253.01
077253.01
88'-1 1/2"
077200
MEMBRANE
STRUCTURE -SEE STRUCTURAL
DRAWINGS
GYPSUM WALL BOARD
1 LOW SLOPE MEMBRANE ROOF
2 LOW SLOPE MEMBRANE ROOF
STANDING SEAM METAL
ROOFING
PLYWOOD SHEATHING -SEE
STRUCTURAL DRAWINGS
PLYWOOD SHEATHING -SEE
STRUCTURAL DRAWINGS
OVER ICE & WATER SHIELD -
EXTEND OVER ENTIRE ROOF
FULL THICKNESS BATT ISULATION
STRUCTURE -SEE STRUCTURAL
DRAWINGS
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
0
:
2
9
P
M
A4.1
ROOF PLAN
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
GENERAL NOTES
1. LOW SLOPE ROOF: MIN. ROOF SLOPE IS 1/4" PER FOOT. MIN. ROOF CRICKET SLOPE 1/2"
PER FOOT UNLESS NOTED OTHERWISE.
2. REFER TO MECHANICAL DRAWINGS FOR NUMBER AND LOCATION OF V.T.R.'s, EXHAUST
VENTS, ROOF DRAINS, MISC. ROOF PENETRATIONS AND ADDITIONAL INFORMATION.
PROVIDE CRICKETS BEHIND CURBS ON SLOPED ROOFS.
3. VERIFY EXACT NUMBER OF V.T.R.'s AND OTHER ROOF MOUNTED EQUIPMENT WITH
MECHANICAL DRAWINGS. NOT ALL ARE SHOWN.
4. ROOFING CONTRACTOR TO USE APPROPRIATE MANUFACTURER'S DETAILS @ V.T.R.'s,
MECH. CURBS, ETC. TO OBTAIN/MAINTAIN ROOF WARRANTIES. FOLLOW ROOFING MFR.
SYSTEM REQUIREMENTS FOR ALL TERMINATIONS AND SEAMS.
5. WHERE VAPOR BARRIER IS PENETRATED AND AT PERIMETERS OF VAPOR BARRIER,
ENSURE VAPOR BARRIERS ARE SEALED TIGHT.
6. REFER TO ELECTRICAL DRAWINGS FOR ALL CONDUIT PENETRATIONS REQUIRED AT
ROOF.
7. REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING MEMBERS AND DETAILS.
8. PROVIDE MIN. 12" WIDE SPLICE PLATE BENEATH ALL JOINTS IN PARAPET COPING
ROOF SYSTEMS
ROOF LEGEND
1/8" = 1'-0"A4.1
1 ROOF PLAN
PROJECT
NORTH
T R U E
N O R T H
KEYED NOTES
075419 POLYVINYL-CHLORIDE (PVC) ROOFING
077200 ROOF ACCESS HATCH - INSTALL PER MANUFACTURER'S RECOMMENDATIONS
077253.01 STANDING SEAM METAL ROOF
077253.02 PRE-FINISHED METAL PARAPET CAP
no. description date
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
1
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. PARAPET 2
ELEV.35' -9 3/4"
SHEATHING -SEE
STRUCTURAL DRAWINGS
ICE AND WATER SHIELD -EXTEND
UP AND OVER PARAPET
ROOF MEMBRANE WRAP UP WALL
2' MIN.
SHEATHING -SEE STRUCTURAL
DRAWINGS
2X FRAMING -SEE STRUCTURAL
DRAWINGS
BATT INSULATION R21 MIN.
ROOF FRAMING -SEE STRUCTURAL DRAWINGS
DOUBLE LAYER OF TYPE X GYPSUM BOARD
TYPE X GYPSUM WALL BOARD
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
BATT INSULATION R21 MIN.
VINYL WINDOW-SEE A10 SERIES FOR
WINDOW TYPES
SHEATHING -SEE STRUCTURAL
DRAWINGS
BLOCKING
PRE-FINISHED METAL PARAPET
CAP WITH DRIP EDGE
SHEATHING -SEE STRUCTURAL
DRAWINGS
AIR INFILTRATION BARRIER -
TAPE SEAMS
EFIS SIDING WITH 2" RIGID
INSULATION
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
SHEATHING -SEE
STRUCTURAL DRAWINGS
ICE AND WATER SHIELD -EXTEND
UP AND OVER PARAPET
ROOF MEMBRANE WRAP UP WALL
2' MIN.
SHEATHING -SEE STRUCTURAL
DRAWINGS
2X FRAMING -SEE STRUCTURAL
DRAWINGS
BATT INSULATION R21 MIN.
SHEATHING -SEE STRUCTURAL DRAWINGS
BLOCKING
PRE-FINISHED METAL PARAPET CAP
WITH DRIP EDGE
SHEATHING -SEE STRUCTURAL DRAWINGS
AIR INFILTRATION BARRIER -TAPE SEAMS
EFIS SIDING WITH 2" RIGID INSULATION
ROOF FRAMING -SEE STRUCTURAL DRAWINGS
DOUBLE LAYER OF TYPE X GYPSUM BOARD
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
BATT INSULATION R21 MIN.
ALUMINUM STOREFRONT WINDOW-SEE A10
SERIES FOR WINDOW TYPES
B
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
SHEATHING -SEE
STRUCTURAL DRAWINGS
ICE AND WATER SHIELD -EXTEND
UP AND OVER PARAPET
ROOF MEMBRANE WRAP UP WALL
2' MIN.
SHEATHING -SEE STRUCTURAL
DRAWINGS
2X FRAMING -SEE STRUCTURAL
DRAWINGS
BATT INSULATION R21 MIN.
SHEATHING -SEE STRUCTURAL DRAWINGS
BLOCKING
PRE-FINISHED METAL PARAPET CAP
WITH DRIP EDGE
SHEATHING -SEE STRUCTURAL DRAWINGS
AIR INFILTRATION BARRIER -TAPE SEAMS
EFIS SIDING WITH 2" RIGID INSULATION
STRUCTURAL BEAM -SEE STRUCTURAL DRAWINGS
ROOF FRAMING -SEE STRUCTURAL DRAWINGS
DOUBLE LAYER OF TYPE X GYPSUM BOARD
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
BATT INSULATION R21 MIN.
ALUMINUM STOREFRONT WINDOW-SEE A10
SERIES FOR WINDOW TYPES
GYPSUM WALL BOARD
SHEATHING -SEE STRUCTURAL DRAWINGS
ENGINEERED WOOD SIDING
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
0
:
3
0
P
M
A4.2
ROOF DETAILS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1. PROVIDE BACKING PLATES IN STUD WALLS FOR ALL TOILET ACCESSORIES, CASEWORK,
ETC.
2. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
OR STRUCTURAL DRAWINGS, CONTACT ARCHITECT FOR CLARIFICATION.
3. ALL G.W.B. TO BE 5/8" UNLESS NOTED OTHERWISE.
4. USE WATER RESISTANT G.W.B. IN ALL WET AREAS.
5. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIAL, EXCEPT
STONE.
6. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
7. LOCATE DOOR R.O. 3" FROM ADJACENT STUD WALL UNLESS NOTED OTHERWISE.
8. SEE A1 SERIES FOR WALL TYPES
9. SEE SHEET A2.1 FOR ROOM FINISH SCHEDULE.
10. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
11. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
GENERAL NOTES
1" = 1'-0"A4.2
1 ROOF DETAIL @ GRID 1
1" = 1'-0"A4.2
2 ROOF DETAIL @ GRID A
1" = 1'-0"A4.2
3 ROOF DETAIL @ GRID B,A
no. description date
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
1
A5.3
________
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
1
T.O. PARAPET 3
ELEV.37' -0"
5610 37
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
29482
A5.3
________2
A5.4
________1
A5.5
________1
A5.4
________2
CR1.4
________________2
A6.2
092900
064023.01
113013.06
123530
EEE23 301 EE E29
E20EE201EEE14
E3 EE
101
EE E11
092900
064023.01
113013.06
123530
103E
103C
103A 103 104A
104C
104E
204E
204C
204A
202
203A
203C
203E
303E
303C 303A
302
304A
304C
304E
064023.01
113013.05
123530
092900092900
092900
092900 092900
092900
092900 092900
092900
092900
123530
113013.05
123530
113013.06
064023.01
064023.01
064023.01
123530
113013.06
260000260000260000
260000260000260000
260000260000260000
260000
260000
260000
312113312113
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
1
A5.3
________
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
1
T.O. PARAPET 3
ELEV.37' -0"
5610 37
T.O. FOOTING 96' -0"
ELEV.-4' -0"
29482
A5.3
________2
A5.4
________1
A5.5
________1
A5.4
________2
CR1.4
________
224100.01
113013.07
093013.01
064116
B301B
113013.04
113013.08
092900 C
C
CBB101
201 BBC
C
C
092900
092900092900
092900
092900
224100.01
113013.07
093013.01
064116
113013.04
113013.08
224100.01
113013.07
064116
093013.01
113013.04
113013.08
064116
224100.01
113013.07
093013.01
064116
113013.04
113013.08
113013.04
113013.08224100.01
113013.07
093013.01
064116
224100.01
113013.07
093013.01
064116
113013.04
113013.08
260000
260000
260000
312113 312113
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
0
:
3
4
P
M
A5.1
BUILDING
SECTIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
GENERAL NOTES
1. SEE A1 SERIES FOR WALL TYPES.
2. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
3. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
4. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
AND STRUCTURAL, CONTACT ARCHITECT FOR CLARIFICATION.
5. ALL G.W.B. TO BE 5/8".
6. SEE STRUCTURAL DRAWINGS FOR CONTROL JOINTS IN ON GRADE SLABS,EXCEPT STONE
7. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIALS
8. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
9. PROVIDE BACKING PLATES IN FRAMED WALLS FOR ALL CASEWORK, TOILET
ACCESSORIES AND OTHER WALL MOUNTED ITEMS.
1/8" = 1'-0"A5.1
1 BUILDING SECTION A
1/8" = 1'-0"A5.1
2 BUILDING SECTION B
KEYED NOTES
064023.01 INTERIOR ARCHITECTURAL WOODWORK - 1X4 BASE
064116 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
092900 GYPSUM BOARD
093013.01 CERAMIC TILING - WALL TILE
113013.04 RESIDENTIAL APPLIANCES - OVEN WITH STOVETOP - CONTROLLS TO BE LOCATED
IN FRONT OF STOVE TOP
113013.05 RESIDENTIAL APPLIANCES - WASHER DRYER COMBO
113013.06 RESIDENTIAL APPLIANCES - WASHER AND DRYER STACKABLE UNIT
113013.07 RESIDENTIAL APPLIANCES - REFRIDGERATOR
113013.08 RESIDENTIAL APPLIANCES - ABOVE RANGE MICROWAVE WITH VENT
123530 RESIDENTIAL CASEWORK
224100.01 RESIDENTIAL PLUMBING FIXTURES - TUB
260000 ELECTRICAL FIXTURE OR EQUIPMENT - SEE ELECTRICAL
312113 RADON MITIGATION SYSTEM
no. description date
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
1
A5.3
________
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
1
T.O. PARAPET 3
ELEV.37' -0"
5610 37
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
29482
A5.3
________2
A5.4
________1
A5.5
________1
A5.4
________2
CR1.4
________________3
A6.2
M
M
MG
G
G303
203
104Ee
E
EG
G
G
123530
092900
123623.43
092900
123530
092900
092900
092900
092900
092900
092900
092900
092900
092900
092900
064023.01
064023.01
064023.01
096513
096513
096513
064116.10
064116.10
064116.10064116.10
064116.10
064116.10
224100.03
064116
113013.08
093013.01
123661.19
224100.03
123661.19
093013.01
113013.08
064116
224100.03
123623.33
093013.01
113013.08
064116
312113 312113
C
C
C
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
1
A5.3
________
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
1
T.O. PARAPET 3
ELEV.37' -0"
5610 37
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
29482
A5.3
________2
A5.4
________1
A5.5
________1
A5.4
________2
CR1.4
________
E25
E16
E5 E8
E17
E26303
203
104
092900
092900
092900
074643.13
074643.13
074643.13
092900
092900
074643.13
092900
074643.13
074643.13
074643.13
072413
077253.01
260000
240000
260000
064113
064113
064113
312113312113312113312113
D
D
D
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
0
:
4
1
P
M
A5.2
BUILDING
SECTIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
GENERAL NOTES
1. SEE A1 SERIES FOR WALL TYPES.
2. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
3. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
4. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
AND STRUCTURAL, CONTACT ARCHITECT FOR CLARIFICATION.
5. ALL G.W.B. TO BE 5/8".
6. SEE STRUCTURAL DRAWINGS FOR CONTROL JOINTS IN ON GRADE SLABS,EXCEPT STONE
7. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIALS
8. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
9. PROVIDE BACKING PLATES IN FRAMED WALLS FOR ALL CASEWORK, TOILET
ACCESSORIES AND OTHER WALL MOUNTED ITEMS.
1/8" = 1'-0"A5.2
1 BUILDING SECTION C
1/8" = 1'-0"A5.2
2 BUILDING SECTION D
KEYED NOTES
064023.01 INTERIOR ARCHITECTURAL WOODWORK - 1X4 BASE
064113 OAK-VENEERED PARTICLE BOARD CABINETS W/SOLID OAK PANEL DOORS &
DRAWERS
064116 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
064116.10 PLASTIC-LAMINATE-CLAD PANELING
072413 EXTERIOR INSULATION FINISH SYSTEM (EIFS) - DRYVIT OUTSULATION SYSTEM - OR
EQUIL
074643.13 ENGINEERED WOOD SIDING
077253.01 STANDING SEAM METAL ROOF
092900 GYPSUM BOARD
093013.01 CERAMIC TILING - WALL TILE
096513 RESILIENT BASE - SEE A2 SERIES FOR BASE FINISH AND DETAILS
113013.08 RESIDENTIAL APPLIANCES - ABOVE RANGE MICROWAVE WITH VENT
123530 RESIDENTIAL CASEWORK
123623.33 WOOD COUNTERTOP MATERIAL - MOUNTED AND SUPPORTED AT BENCH HEIGHT
123623.43 SHELF WITH CLOSE ROD
123661.19 QUARTS AGGLOMERATE COUNTERTOPS
224100.03 RESIDENTIAL PLUMBING FIXTURES - KITCHEN FAUCET
240000 PLUMBING FIXTURE OR EQUIPMENT - SEE PLUMBING
260000 ELECTRICAL FIXTURE OR EQUIPMENT - SEE ELECTRICAL
312113 RADON MITIGATION SYSTEM
no. description date
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
BCDEG
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
F A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
1
A5.1
________2
A5.1
________1
A5.2
________2
A5.2
________1
CR1.4
________
B
B
B105 B
B
B B
B
B B
201B
301B303
203
104 101 102
092900
092900
092900092900
092900
092900092900
092900
092900092900
092900
092900
064023.01
064023.01
064023.01064023.01
064023.01
064023.01064023.01
064023.01
064023.01 064023.01
064023.01
064023.01
3'
-
6
"
3'
-
6
"
3'
-
6
"
3'
-
6
"
312113 312113
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
BCDEG
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
F A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
1
A5.1
________2
A5.1
________1
A5.2
________2
A5.2
________1
CR1.4
________________2
A6.1
064023.01
064116
092900
064116
224100.02
064023.01
064116
092900
064116
224100.02
064023.01
064116
092900
064116
224100.02
064116
064023.01
224100.03
064116
224100.02B B
BB
B BB
B
BB
B
B
064116
064023.01
224100.03
064116
224100.02
064116
064023.01
224100.03
064116
224100.02
064023.01
064116
092900
064116
224100.02
064023.01
064116
092900
064116
224100.02
064023.01
064116
092900
064116
224100.02
064116
064023.01
224100.03
064116
224100.02
064116
064023.01
224100.03
064116
224100.02
064116
064023.01
224100.03
064116
224100.02
312113312113
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
0
:
4
6
P
M
A5.3
BUILDING
SECTIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"A5.3
1 BUILDING SECTION E
GENERAL NOTES
1. SEE A1 SERIES FOR WALL TYPES.
2. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
3. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
4. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
AND STRUCTURAL, CONTACT ARCHITECT FOR CLARIFICATION.
5. ALL G.W.B. TO BE 5/8".
6. SEE STRUCTURAL DRAWINGS FOR CONTROL JOINTS IN ON GRADE SLABS,EXCEPT STONE
7. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIALS
8. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
9. PROVIDE BACKING PLATES IN FRAMED WALLS FOR ALL CASEWORK, TOILET
ACCESSORIES AND OTHER WALL MOUNTED ITEMS.
1/8" = 1'-0"A5.3
2 BUILDING SECTION F
KEYED NOTES
064023.01 INTERIOR ARCHITECTURAL WOODWORK - 1X4 BASE
064116 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
092900 GYPSUM BOARD
224100.02 RESIDENTIAL PLUMBING FIXTURES - KITCHEN SINK
224100.03 RESIDENTIAL PLUMBING FIXTURES - KITCHEN FAUCET
312113 RADON MITIGATION SYSTEM
no. description date
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
BCDEG
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
F A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
1
A5.1
________2
A5.1
________1
A5.2
________2
A5.2
________1
CR1.4
________________3
A6.1
092900
230000
093013.03
123661.19
064116123530
092900
K
K
K
B
BB
BE
E
Ee
K
K
K
064113
123661.19
096513
224100.01
224100.05123530
092900
064116
123661.19
230000
096513
064116
123661.19
230000
096513
123530
092900
064113
123661.19
096513
224100.01
224100.04092900
064023.01E9
E18
E27
230000
123530
092900
064113
123661.19
096513
224100.01
224100.04092900
064023.01
123530
092900
064113
123661.19
096513
224100.01
224100.04092900
064023.01
064116
230000
096513
064116
230000
096513
123661.19
123661.19
123530
092900
064116
123661.19
230000
096513
123530
092900
064116
123661.19
230000
096513
092900
230000
092900
123661.19
064116
092900
230000
092900
123661.19
064116
123530
092900
064113
123661.19
096513
224100.01
224100.05
123530
092900
064113
123661.19
096513
224100.01
224100.05
260000
123530
092900
123530
092900
123530
092900
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
BCDEG
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
F A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
1
A5.1
________2
A5.1
________1
A5.2
________2
A5.2
________1
CR1.4
________________1
A6.2
Ff
F
F
EeLl
L E
ELEE
EE
EEEE
EE
EEE
E
EeE9
E18
E27
092900
064023.01064023.01
092900
092900
064023.01064023.01
092900
092900
064023.01064023.01
092900
092900
092900
092900
092900
092900
092900
G
G
G
092900
123530
064023.01
123530
092900
064023.01
123530
092900
064023.01
092900
064023.01
092900
064023.01
092900
064023.01
092900
064023.01
092900
064023.01
092900
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
0
:
5
3
P
M
A5.4
BUILDING
SECTIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"A5.4
1 BUILDING SECTION G
1/8" = 1'-0"A5.4
2 BUILDING SECTION H
GENERAL NOTES
1. SEE A1 SERIES FOR WALL TYPES.
2. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
3. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
4. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
AND STRUCTURAL, CONTACT ARCHITECT FOR CLARIFICATION.
5. ALL G.W.B. TO BE 5/8".
6. SEE STRUCTURAL DRAWINGS FOR CONTROL JOINTS IN ON GRADE SLABS,EXCEPT STONE
7. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIALS
8. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
9. PROVIDE BACKING PLATES IN FRAMED WALLS FOR ALL CASEWORK, TOILET
ACCESSORIES AND OTHER WALL MOUNTED ITEMS.
KEYED NOTES
064023.01 INTERIOR ARCHITECTURAL WOODWORK - 1X4 BASE
064113 OAK-VENEERED PARTICLE BOARD CABINETS W/SOLID OAK PANEL DOORS &
DRAWERS
064116 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
092900 GYPSUM BOARD
093013.03 CERAMIC TILING - SHOWER TILE
096513 RESILIENT BASE - SEE A2 SERIES FOR BASE FINISH AND DETAILS
123530 RESIDENTIAL CASEWORK
123661.19 QUARTS AGGLOMERATE COUNTERTOPS
224100.01 RESIDENTIAL PLUMBING FIXTURES - TUB
224100.04 RESIDENTIAL PLUMBING FIXTURES - BATHROOM SINK
224100.05 RESIDENTIAL PLUMBING FIXTURES - BATHROOM FAUCET
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
260000 ELECTRICAL FIXTURE OR EQUIPMENT - SEE ELECTRICAL
no. description date
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
BCDEG
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
F A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
1
A5.1
________2
A5.1
________1
A5.2
________2
A5.2
________1
CR1.4
________
F
F
Ff
C
C
C
E29
E20
E11E4
E19
E28
C
C
C
L
L
L
F
F
Ff
J
J
J
092900
064023.01
123530
G
G
G
JJ
JJ
JJ
074643.13074643.13
074643.13074643.13
074643.13074643.13
074643.13 074643.13
074643.13 074643.13
074643.13
074643.13
230000
230000
092900
096513
123530
230000
230000
092900
096513
123530
230000
230000
230000230000
230000230000
230000230000
230000230000
230000230000
230000230000
230000230000
092900
064023.01
230000230000
092900
230000230000
092900
096513
096513
093013.03
064113
123661.19
096513
092900
064113
096513
092900
064113
096513
312113312113312113312113312113312113
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
0
:
5
7
P
M
A5.5
BUILDING
SECTIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
GENERAL NOTES
1. SEE A1 SERIES FOR WALL TYPES.
2. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULES.
3. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
4. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL
AND STRUCTURAL, CONTACT ARCHITECT FOR CLARIFICATION.
5. ALL G.W.B. TO BE 5/8".
6. SEE STRUCTURAL DRAWINGS FOR CONTROL JOINTS IN ON GRADE SLABS,EXCEPT STONE
7. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MATERIALS
8. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF STUD OR GRID LINE UNLESS NOTED
OTHERWISE.
9. PROVIDE BACKING PLATES IN FRAMED WALLS FOR ALL CASEWORK, TOILET
ACCESSORIES AND OTHER WALL MOUNTED ITEMS.
1/8" = 1'-0"A5.5
1 BUILDING SECTION J
KEYED NOTES
064023.01 INTERIOR ARCHITECTURAL WOODWORK - 1X4 BASE
064113 OAK-VENEERED PARTICLE BOARD CABINETS W/SOLID OAK PANEL DOORS &
DRAWERS
074643.13 ENGINEERED WOOD SIDING
092900 GYPSUM BOARD
093013.03 CERAMIC TILING - SHOWER TILE
096513 RESILIENT BASE - SEE A2 SERIES FOR BASE FINISH AND DETAILS
123530 RESIDENTIAL CASEWORK
123661.19 QUARTS AGGLOMERATE COUNTERTOPS
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
312113 RADON MITIGATION SYSTEM
no. description date
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
________2
A4.2
SLAB ON GRADE -SLOPE AWAY FROM STRUCTURE
STRUCTURAL FOOTING AND FOUNDATION WALL -
SEE STRUCTURAL DRAWINGS
RIGID INSULATION
GRAVEL BASE
RADON MITIGATION SYSTEM
SLAB ON GRADE
FINISH FLOOR
FIBER EXPANSION BOARD
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
ROOF FRAMING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
ROOF SHEATHING -SEE STRUCTURAL DRAWINGS
ICE AND WATER SHIELD EXTEND OVER ENTIRE ROOF
AND UP AND OVER WALL
MEMBRANE ROOF SYSTEM
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
GRAVEL BASE
METAL PANEL SIDING
SHEATHING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
SHEATHING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
EFIS SIDING WITH R10 RIGID INSULATION
PRE-FINISHED METAL PARAPET CAP WITH DRIP
EDGE
METAL PANEL SIDING
SHEATHING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
301
201
101
AIR INFILTRATION BARRIER -TAPE SEAMS
AIR INFILTRATION BARRIER -TAPE SEAMS
AIR INFILTRATION BARRIER -TAPE SEAMS
DAMPROOFING
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
B
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
________3
A4.2
SLAB ON GRADE -SLOPE AWAY FROM STRUCTURE
ENGINEERED WOOD SIDING
SHEATHING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
STRUCTURAL FOOTING AND FOUNDATION WALL -
SEE STRUCTURAL DRAWINGS
RIGID INSULATION
GRAVEL BASE
RADON MITIGATION SYSTEM
SLAB ON GRADE
FINISH FLOOR
FIBER EXPANSION BOARD
GYPSUM WALL BOARD
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
ROOF FRAMING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
ROOF SHEATHING -SEE STRUCTURAL DRAWINGS
ICE AND WATER SHIELD EXTEND OVER ENTIRE ROOF
AND UP AND OVER WALL
MEMBRANE ROOF SYSTEM
STRUCTURAL BEAM -SEE
STRUCTURAL DRAWINGS
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
GRAVEL BASE
FINISH GRADE -SLOPE AWAY FROM STRUCTURE
GYPSUM WALL BOARD
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
GYPSUM WALL BOARD
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
4" CONCRETE SLAB ON STRUCTURAL DECK -SEE
STRUCTURAL DRAWINGS
4" CONCRETE SLAB ON STRUCTURAL DECK -SEE
STRUCTURAL DRAWINGS
E21
E30
E12
ENGINEERED WOOD SIDING
SHEATHING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
ENGINEERED WOOD SIDING
SHEATHING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
EFIS SIDING WITH R10 RIGID
INSULATION
PRE-FINISHED METAL PARAPET
CAP WITH DRIP EDGE
302A
202A
102A
AIR INFILTRATION BARRIER -TAPE SEAMS
AIR INFILTRATION BARRIER -TAPE SEAMS
AIR INFILTRATION BARRIER -TAPE SEAMS
DAMPROOFING
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
B
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
FINISH GRADE -SLOPE AWAY FROM STRUCTURE
ENGINEERED WOOD SIDING
SHEATHING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
STRUCTURAL FOOTING AND FOUNDATION WALL -
SEE STRUCTURAL DRAWINGS
RIGID INSULATION
GRAVEL BASE
RADON MITIGATION SYSTEM
SLAB ON GRADE
FINISH FLOOR
FIBER EXPANSION BOARD
2X FRAMING -SEE STRUCTURAL DRAWINGS
GYPSUM WALL BOARD
GYPSUM WALL BOARD CEILING ON FRAMING -
SEE A11 SERIES FOR CEILING TYPES
MECHANICAL FIXTURE OR EQUIPMENT -SEE
MECHANICAL DRAWINGS
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
GYPSUM WALL BOARD CEILING ON FRAMING -
SEE A11 SERIES FOR CEILING TYPES
MECHANICAL FIXTURE OR EQUIPMENT -SEE
MECHANICAL DRAWINGS
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
GYPSUM WALL BOARD CEILING ON FRAMING -
SEE A11 SERIES FOR CEILING TYPES
MECHANICAL FIXTURE OR EQUIPMENT -SEE
MECHANICAL DRAWINGS
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
ROOF FRAMING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
ROOF SHEATHING -SEE STRUCTURAL DRAWINGS
ICE AND WATER SHIELD EXTEND OVER ENTIRE
ROOF AND UP AND OVER WALL
MEMBRANE ROOF SYSTEM
ENGINEERED WOOD SIDING
SHEATHING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
ENGINEERED WOOD SIDING
SHEATHING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
ENGINEERED WOOD SIDING
SHEATHING -SEE STRUCTURAL DRAWINGS
PRE-FINISHED METAL PARAPET CAP WITH DRIP EDGE
302H302F
202H202F
102H102H
AIR INFILTRATION BARRIER -TAPE SEAMS
AIR INFILTRATION BARRIER -TAPE SEAMS
AIR INFILTRATION BARRIER -TAPE SEAMS
DAMPROFFING
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
0
2
:
0
5
P
M
A6.1
WALL SECTIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1. NOT ALL INTERIOR FINISHES AND CABINETS ARE SHOWN ON BUILDING SECTIONS, SEE
ROOM FINISH SCHEDULE AND INTERIOR ELEVATIONS.
2. SEE A1 SERIES FOR WALL TYPES.
3. SEE A6 SERIES FOR WALL SECTIONS.
4. SEE A8 SERIES FOR INTERIOR ELEVATIONS.
5. SEE A10 SERIES FOR DOOR SCHEDULE & WINDOW SCHEDULE.
6. ALL VAPOR BARRIER MUST BE SEALED OR TAPED AT ALL PENETRATIONS & OPENINGS.
7. ALL EXTERIOR FOUNDATION WALLS BELOW GRADE SHALL BE PROVIDED WITH
DAMPPROOFING AT EXTERIOR AND 2" RIGID INSULATION AT INTERIOR, SEE WALL TYPES
ON A1 SERIES.
8. SEE REFLECTED CEILING PLAN ON A11 SERIES AND ROOM FINISH SCHEDULE SHEET A2.1
FOR CEILING INFORMATION.
GENERAL NOTES
3/8" = 1'-0"A6.1
1 WALL SECTION @CORIDOR GRID A
3/8" = 1'-0"A6.1
2 WALL SECTION @ BALCONY GRID B&A
3/8" = 1'-0"A6.1
3 WALL SECTIONS @ GRID B &A
no. description date
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
C
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
STRUCTURAL FOOTING AND FOUNDATION WALL -
SEE STRUCTURAL DRAWINGSGRAVEL BASE
SLAB ON GRADE
FINISH FLOOR
2X FRAMING -SEE STRUCTURAL DRAWINGS
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
ROOF FRAMING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
ROOF SHEATHING -SEE STRUCTURAL DRAWINGS
ICE AND WATER SHIELD EXTEND OVER ENTIRE ROOF
AND UP AND OVER WALL
MEMBRANE ROOF SYSTEM
GYPSUM WALL BOARD
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
GYPSUM WALL BOARD
GYPSUM WALL BOARD
1X4 WOOD BASE TRIM
FULL THICKNESS BATT INSULATION
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
GYPSUM WALL BOARD
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
GYPSUM WALL BOARD
GYPSUM WALL BOARD
FULL THICKNESS BATT INSULATION
FULL THICKNESS BATT INSULATION
FULL THICKNESS BATT INSULATION
1X4 WOOD BASE TRIM 1X4 WOOD BASE TRIM
1X4 WOOD BASE TRIM
AIR SPACE
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
1X4 WOOD BASE TRIM
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
1X4 WOOD BASE TRIM
AIR SPACE
AIR SPACE
302L304E
204E 202L
102L104E
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
5
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
STRUCTURAL FOOTING AND FOUNDATION WALL -
SEE STRUCTURAL DRAWINGSGRAVEL BASE
SLAB ON GRADE
FINISH FLOOR
2X FRAMING -SEE STRUCTURAL DRAWINGS
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
ROOF FRAMING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
ROOF SHEATHING -SEE STRUCTURAL DRAWINGS
ICE AND WATER SHIELD EXTEND OVER ENTIRE ROOF
AND UP AND OVER WALL
MEMBRANE ROOF SYSTEM
GYPSUM WALL BOARD
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
GYPSUM WALL BOARD
GYPSUM WALL BOARD
1X4 WOOD BASE TRIM
FULL THICKNESS BATT INSULATION
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
GYPSUM WALL BOARD
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
GYPSUM WALL BOARD
GYPSUM WALL BOARD
FULL THICKNESS BATT INSULATION
FULL THICKNESS BATT INSULATION
FULL THICKNESS BATT INSULATION
1X4 WOOD BASE TRIM
1X4 WOOD BASE TRIM
1X4 WOOD BASE TRIM
1X4 WOOD BASE TRIM
1X4 WOOD BASE TRIM
104A103
202 204A
304A302
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
1
T.O. PARAPET 3
ELEV.37' -0"
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
________1
A4.2
FINISH GRADE -SLOPE AWAY FROM STRUCTURE
STRUCTURAL FOOTING AND FOUNDATION WALL -
SEE STRUCTURAL DRAWINGS
RIGID INSULATION
GRAVEL BASE
RADON MITIGATION SYSTEM
SLAB ON GRADE
FINISH FLOOR
FIBER EXPANSION BOARD
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
FLOOR STRUCTURE -SEE STRUCTURAL
DRAWINGS
FULL THICKNESS BATT INSULATION
SUBFLOOR -SEE STRUCTURAL DRAWINGS
CONCRETE SLAB ON STRUCTURE -SEE
STRUCTURAL DRAWINGS
FINISH FLOOR
ROOF FRAMING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
ROOF SHEATHING -SEE STRUCTURAL DRAWINGS
ICE AND WATER SHIELD EXTEND OVER ENTIRE ROOF
AND UP AND OVER WALL
MEMBRANE ROOF SYSTEM
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
EFIS SIDING WITH R10 RIGID INSULATION
PRE-FINISHED METAL PARAPET CAP WITH DRIP
EDGE
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
DOUBLE GYPSUM LAYER SEE A 11 SERIES FOR
CEILING TYPES
STRUCTURAL HEADER -SEE STRUCTURAL
DRAWINGS
2X FRAMING -SEE STRUCTURAL DRAWINGS
BATT INSULATION -R21 MIN.
SHEATHING -SEE STRUCTURAL DRAWINGS
EFIS SIDING WITH R10 RIGID INSULATION
PRE-FINISHED METAL FLASHING WITH DRIP
EDGE -SLOPE AWAY FROM OPENING
C
C
C
GYPSUM WALL BOARD
GYPSUM WALL BOARD
BATT INSULATION -R21 MIN.
SHEATHING -SEE STRUCTURAL DRAWINGS
EFIS SIDING WITH R10 RIGID INSULATION
PRE-FINISHED METAL FLASHING WITH DRIP
EDGE -SLOPE AWAY FROM OPENING
BATT INSULATION -R21 MIN.
SHEATHING -SEE STRUCTURAL DRAWINGS
EFIS SIDING WITH R10 RIGID INSULATION
PRE-FINISHED METAL FLASHING WITH DRIP
EDGE -SLOPE AWAY FROM OPENING
VINYL WINDOW -SEE A140 SERIES FOR WINDOW
TYPES
VINYL WINDOW -SEE A140 SERIES FOR WINDOW
TYPES
VINYL WINDOW -SEE A140 SERIES FOR WINDOW
TYPES
308L
208L
108L
AIR INFILTRATION BARRIER -TAPE SEAMS
AIR INFILTRATION BARRIER -TAPE SEAMS
DAMPROOFING
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
0
0
P
M
A6.2
WALL SECTIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
3/8" = 1'-0"A6.2
1 WALL SECTION @ GRID C
3/8" = 1'-0"A6.2
2 WALL SECTION @ GRID 5
3/8" = 1'-0"A6.2
3 WALL SECTION @ GRID 1
1. NOT ALL INTERIOR FINISHES AND CABINETS ARE SHOWN ON BUILDING SECTIONS, SEE
ROOM FINISH SCHEDULE AND INTERIOR ELEVATIONS.
2. SEE A1 SERIES FOR WALL TYPES.
3. SEE A6 SERIES FOR WALL SECTIONS.
4. SEE A8 SERIES FOR INTERIOR ELEVATIONS.
5. SEE A10 SERIES FOR DOOR SCHEDULE & WINDOW SCHEDULE.
6. ALL VAPOR BARRIER MUST BE SEALED OR TAPED AT ALL PENETRATIONS & OPENINGS.
7. ALL EXTERIOR FOUNDATION WALLS BELOW GRADE SHALL BE PROVIDED WITH
DAMPPROOFING AT EXTERIOR AND 2" RIGID INSULATION AT INTERIOR, SEE WALL TYPES
ON A1 SERIES.
8. SEE REFLECTED CEILING PLAN ON A11 SERIES AND ROOM FINISH SCHEDULE SHEET A2.1
FOR CEILING INFORMATION.
GENERAL NOTES
no. description date
2'-0"2'-0"1'-6"1'-6"
5'-0"
064116
123661.19
224100.05
092900
096513
093013.03
113013.07
113013.01
064116064116 113013.04
064116
064116064116064116064116064116
123661.19
224100.03
093013.01
113013.08
3'-0"2'-0"2'-6"
2'
-
1
0
"
3'
-
0
"
2'-9"2'-0"3'-0"2'-0"2'-6"2'-6"
092900
113013.05
123530
092900
1'-4"3'-8 3/4"1'-4"
6'
-
7
3
/
4
"
123530123530
092900
123623.43
1'-6"1'-6"2'-0"2'-0"
5'-0"
2'
-
1
0
"
123661.19
224100.05
064116
064116
066113.10
092900
093013.03
113013.07
113013.01
064116064116
224100.03
123661.19
093013.01
113013.04
064116
123530
113013.08
064116064116064116064116064116064116
3'
-
0
"
2'-9"2'-0"3'-0"2'-0"2'-6"1'-0"1'-6"
3'-0"2'-0"1'-0"1'-6"
1'-4"3'-8 3/4"1'-4"
6'
-
8
"
123530123530
092900
1'-4"2'-6"1'-6"1'-6"
096513
064116
123661.19
224100.05
092900
066113.10
093013.03
3'-0"2'-6"1'-2"2'-6"3'-0"
3'-0"1'-2"2'-6"
113013.07 064116 113013.04
064116
064116064116
093013.01
113013.08
064116
064116064116
123661.19
123623.33
092900
092900
3'
-
0
"
2'
-
1
0
"
1'-2"3'-0"2'-6"
3'
-
0
"
2'
-
1
0
"
064023.01
092900
123661.19
113013.01
064116
224100.03
064116064116
2'-6 3/4"
6'
-
8
"
113013.05
092900
123530
1'-4"3'-3 1/4"1'-4"
6'
-
8
"
123530123530
064023.01
092900
2'-6"2'-0"1'-6"1'-6"
5'-0"
2'
-
1
0
"
064116
064116
123661.19
224100.05
066113.10
092900
093013.03
3'-0"3'-0"2'-6"1'-2"2'-6"
3'-0"1'-2"2'-6"
3'
-
0
"
113013.07
064116 113013.04
064116
064116064116
093013.01
064116
064116
113013.08123661.19
064116 064116
123623.33
3'
-
0
"
1'-2"3'-0"2'-6"
113013.01
064116 064116
064116
123661.19
224100.03
064023.01
092900
3'-0"1/2"1'-4"1'-6"
064116
096513
123661.19
224100.05
092900
066113.10
093013.03
1'-2 1/4"
123530
092900
2'-6"2'-0"1'-6"1'-6"
4'-6"3'-0"
2'
-
1
0
"
092900 093013.03
123661.19
064116
064116
1'-4"3'-0"1'-6"1'-6"
3'
-
0
"
064116
064113
123661.19
224100.05
224100.01
2'-6 3/4"
6'
-
7
3
/
4
"
123530
113013.05
092900
113013.06
113013.06
123530
092900
064023.01
113013.06
123530
113013.06
092900
113013.06
113013.06
123530
092900
096513
064113
123661.19
064116
224100.05
092900
066113.10
D
093013.03
084523.01
220000.01
092900
E6
084523.01
220000.01
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
0
9
:
5
8
P
M
A8.1
INTERIOR
ELEVATIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
GENERAL NOTES
1. SEE A1 SERIES FOR WALL TYPES.
2. SEE A2 SERIES FOR ROOM FINISH SCHEDULE.
3. SEE A7 SERIES FOR TOILET ACCESSORY MOUNTING HEIGHTS.
4. SEE A10 SERIES FOR DOOR & WINDOW SCHEDULE.
5. SEE A11 SERIES FOR REFLECTED CEILING PLANS.
6. IF A CONFLICT OR DISCREPANCY OCCURS BETWEEN FLOOR PLANS OF ARCHITECTURAL,
STRUCT., MECH. OR ELEC. DWGS., CONTACT ARCHITECT FOR CLARIFICATION.
7. ALL G.W.B. TO BE 5/8" TYPE 'X', EXCEPT AS NOTED.
8. CONTRACTOR TO SUBMIT A CONTROL JOINT PLAN TO THE ARCHITECT FOR REVIEW AND
APPROVAL PRIOR TO POURING CONCRETE.
9. PROVIDE CASING BEAD & CAULK WHERE G.W.B. ABUTS DISSIMILAR MAT'L
10. DIMENSIONS ARE TO FACE OF STUD, FACE OF BLOCK, OR GRID LINE U.N.O.
11. PROVIDE BACKING PLATES IN FRAMED WALLS FOR ALL HANDRAILS, GRAB BARS, TOILET
ACCESSORIES & OTHER WALL MOUNTED ITEMS.
KEYED NOTES
064023.01 INTERIOR ARCHITECTURAL WOODWORK - 1X4 BASE
064113 OAK-VENEERED PARTICLE BOARD CABINETS W/SOLID OAK PANEL DOORS &
DRAWERS
064116 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
066113.10 FIBERGLASS REINFORCED ACRYLIC/ABS - SHOWER BASE
084523.01 FIBERGLASS REINFORECED WALL PANEL
092900 GYPSUM BOARD
093013.01 CERAMIC TILING - WALL TILE
093013.03 CERAMIC TILING - SHOWER TILE
096513 RESILIENT BASE - SEE A2 SERIES FOR BASE FINISH AND DETAILS
113013.01 RESIDENTIAL APPLIANCES - DISHWASHER
113013.04 RESIDENTIAL APPLIANCES - OVEN WITH STOVETOP - CONTROLLS TO BE LOCATED
IN FRONT OF STOVE TOP
113013.05 RESIDENTIAL APPLIANCES - WASHER DRYER COMBO
113013.06 RESIDENTIAL APPLIANCES - WASHER AND DRYER STACKABLE UNIT
113013.07 RESIDENTIAL APPLIANCES - REFRIDGERATOR
113013.08 RESIDENTIAL APPLIANCES - ABOVE RANGE MICROWAVE WITH VENT
123530 RESIDENTIAL CASEWORK
123623.33 WOOD COUNTERTOP MATERIAL - MOUNTED AND SUPPORTED AT BENCH HEIGHT
123623.43 SHELF WITH CLOSE ROD
123661.19 QUARTS AGGLOMERATE COUNTERTOPS
220000.01 PLUMBING FIXTURE - MOP SINK
224100.01 RESIDENTIAL PLUMBING FIXTURES - TUB
224100.03 RESIDENTIAL PLUMBING FIXTURES - KITCHEN FAUCET
224100.05 RESIDENTIAL PLUMBING FIXTURES - BATHROOM FAUCET
1/4" = 1'-0"A8.1
1 MASTER BATHROOM 104F
1/4" = 1'-0"A8.1
2 KITCHEN 104B
1/4" = 1'-0"A8.1
14 LAUNDRY ROOM 104D
1/4" = 1'-0"A8.1
15 MASTER CLOSET 104G
1/4" = 1'-0"A8.1
5 UNIT 1 TYPE B MASTER BATHROOM
1/4" = 1'-0"A8.1
9 KITCEN 204B
1/4" = 1'-0"A8.1
16 MASTER CLOSET 204G
1/4" = 1'-0"A8.1
17 MASTER BATHROOM 204F
1/4" = 1'-0"A8.1
6 KITCHEN 102B A
1/4" = 1'-0"A8.1
8 KITCHEN 102B B
1/4" = 1'-0"A8.1
11 LAUNDRY ROOM 102D
1/4" = 1'-0"A8.1
12 MASTER CLOSET 102G
1/4" = 1'-0"A8.1
20 UNIT 2 TYPE B MASTER BATHROOM
1/4" = 1'-0"A8.1
22 KITCHEN 202B A
1/4" = 1'-0"A8.1
23 KITCHEN 202B B
1/4" = 1'-0"A8.1
25 MASTER BATHROOM 202F
1/4" = 1'-0"A8.1
29 CLOSET 102M
1/4" = 1'-0"A8.1
30 MASTER BATHROOM 102F
1/4" = 1'-0"A8.1
31 BATHROOM 102K
1/4" = 1'-0"A8.1
3 LAUNDRY ROOM 108C
1/4" = 1'-0"A8.1
4 LAUNDRY ROOM 204D
1/4" = 1'-0"A8.1
7 LAUNDRY ROOM 208D
1/4" = 1'-0"A8.1
10 LAUNDRY ROOM 202D
1/4" = 1'-0"A8.1
13 MASTER BATHROOM 208F
1/4" = 1'-0"A8.1
18 JANTOR CLOSET 105 A
1/4" = 1'-0"A8.1
19 JANITOR CLOSET 105 B
no. description date
UP
1716151413121110987654321
FS
TS
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
UP
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
UP DN
1716151413121110987654321
UPDN
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
B
6
7
A
3
A9.1
________
IT
102
1ST FLOOR
STAIR A
101 3'
-
8
"
5'-2"17 TREADS @ 11" = 15'-7"
102
G
6
F
7
2
A5.1
________
6
A9.1
________1ST FLOOR
STAIR B
104
JANITOR
105
105
17 TREADS @ 11" = 15'-7"5'-2"
3'
-
8
"
A8.1
18
19
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
B
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
A
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
18
R
I
S
E
R
S
=
1
0
'
-
3
1
/
4
"
18
R
I
S
E
R
S
=
1
0
'
-
3
1
/
4
"
3'
-
6
"
1'-0"
1'-0"
1ST FLOOR
STAIR A
101
3RD FLOOR
STAIR A
301
________7
A9.1
________7
A9.1
T.O. FLOOR 100' -0"
ELEV.0' -0"
T.O. WALL PLATE 109' -1 1/8"
ELEV.9' -1 1/8"
T.O. FLOOR 110' -3 1/4"
ELEV.10' -3 1/4"
G
T.O. WALL PLATE 119' -4 3/8"
ELEV.19' -4 3/8"
T.O. FLOOR 121' -6 1/2"
ELEV.20' -6 1/2"
T.O. ROOF FRAME 132' -9 3/4"
ELEV.32' -8 3/8"
T.O. PARAPET 3
ELEV.37' -0"
F
T.O. WALL PLATE 129' -7 5/8"
ELEV.29' -7 5/8"
T.O. FOOTING 96' -0"
ELEV.-4' -0"
T.O. PARAPET 2
ELEV.35' -9 3/4"
T.O. PARAPET1
ELEV.34' -8 5/8"
JANITOR
105
1ST FLOOR
STAIR B
104
3'
-
6
"
3'
-
0
"
18
R
I
S
E
R
S
=
1
0
'
-
3
1
/
4
"
18
R
I
S
E
R
S
=
1
0
'
-
3
1
/
4
"
1'-0"
1'-0"
1'-0"
1'-0"
3'
-
0
"
________7
A9.1
________7
A9.1
________7
A9.1
B
6
7
A
3
A9.1
________
5'-2"17 TREADS @ 11" = 15'-7"3'-10"
3'
-
8
"
2ND FLOOR
STAIR A
201
G
6
F
7
2
A5.1
________
6
A9.1
________
4'-0"17 TREADS @ 11" = 15'-7"5'-2"
WALL -SEE WALL TYPES
1 1/2" TUBE STEEL HANDRAIL
SECURED TO WALL W/ 3" X 3/8"
THICK STEEL MOUNTING
FLANGES TO BE 5'-0" MAX. &
SPACED EQUALLY ALONG WALL
3/8" TAPPED HOLE -SECURE TO
WALL -PROVIDE BACKING
1/2" TUBE STEEL SUPPORT
1/4"
1 1/2"1 1/2"
8
A9.1
_____
1 1/2" TUBE STEEL HANDRAIL
SECURED TO WALL W/ 3" X 3/8"
THICK STEEL MOUNTING
FLANGES TO BE 5'-0" MAX. &
SPACED EQUALLY ALONG WALL
3/8" TAPPED HOLE -SECURE TO
WALL -PROVIDE BACKING
1/2" TUBE STEEL SUPPORT
&
S
T
A
I
R
N
O
S
I
N
G
36
"
A
B
O
V
E
S
T
A
I
R
WALL -SEE WALL TYPES
1 1/2"1 1/2"
2"
1 1/4" X 1 1/4" X 3/16" X 6" LONG
STEEL ANGLE -2 PER TREAD -
WELD TO STRINGER & PAN TYP.
2" X 2" X 1/4" X 4" LONG STEEL
ANGLE -1 PER STRINGER -WELD
TO INSIDE OF STRINGER & ATTACH
TO CONCRETE SLAB W/ 3/4" DIA
HILTI KWIK BOLT TZ
3"
C12 STINGER -PAINT
EXPOSED MEMBERS TYP.
2" PAN STAIR TREAD W/
CONCRETE FILL
4" CONCRETE SLAB -SEE
STRUCTURAL
FOUNDATION PLAN
ALUMINUM STAIR NOSING
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
0
8
P
M
A9.1
STAIR PLANS
AND SECTIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/4" = 1'-0"A9.1
1 STAIR A 1ST FLOOR
1/4" = 1'-0"A9.1
4 STAIR B 1ST FLOOR
1/4" = 1'-0"A9.1
3 STAIR A SECTION
1/4" = 1'-0"A9.1
6 STAIR B SECTION
1/4" = 1'-0"A9.1
2 STAIR A 2ND FLOOR
1/4" = 1'-0"A9.1
5 STAIR B 2ND FLOOR
3" = 1'-0"A9.1
7 HANDRAIL RETURN
3" = 1'-0"A9.1
8 HANDRAIL SECTION
1" = 1'-0"A9.1
9 STAIR @ SLAB
no. description date
Riser height 4"-7"as per section
1011.5.2.
A B C D
2"
6'
-
5
"
2"
2'
-
1
"
2"
9'
-
0
"
2"1'-0"2"3'-0"2"
4'-6"
2'
-
8
"
4'
-
0
"
1
1
/
2
"
1'
-
1
"
1
1
/
2
"
5'
-
4
"
1 1/2"2'-9"1 1/2"
3'-0"
2'
-
8
"
4'
-
0
"
1
1
/
2
"
1'
-
1
"
1
1
/
2
"
5'
-
4
"
1 1/2"4'-3"1 1/2"
4'-6"
1
1
/
2
"
3'
-
9
"
1
1
/
2
"
6'
-
8
"
1
1
/
2
"
1'
-
1
"
1
1
/
2
"
1 1/2"5'-9"1 1/2"
6'-0"
HOLLOW METAL
TEMPERED
VINYL FIXED &
CASEMENT
1'
-
4
"
VINYL FIXED &
CASEMENT
VINYL FIXED
C
EXTERIOR VINYL
2 PANEL SLIDING DOOR W/
TRANSOM
D EXTERIOR VINYL
WITH FULL LITE
A EXTERIOR FULL LITE
HOLLOW METAL DOOR E INTERIOR
WOOD DOOR
F
INTERIOR
HOLLOW CORE
MASONITE DOOR
G INTERIOR VINYL
WITH FULL LITE
H INTERIOR HOLLOW CORE
SLIDING MASONITE DOOR
SE
E
S
C
H
.
1'
-
4
"
6'-0"
4'-6"
8"
6'
-
0
"
2"
2'
-
1
1
/
4
"
2"
B
EXTERIOR
FLUSH HOLLOW
METAL DOOR
A BHOLLOW METAL VINYL FRAME
2"
SE
E
S
C
H
.
2"SEE SCH.2"
C WOOD FRAME D MASONITE FRAME
SE
E
S
C
H
.
SEE SCH.SEE SCH.
SE
E
S
C
H
.
SEE SCH.
SE
E
S
C
H
.
1. FIELD VERIFY ALL ROUGH OPENINGS PRIOR TO FABRICATION OF DOOR & WINDOW
FRAMES.
2. PROVIDE SEALANT ENTIRE PERIMETER OF ALL DOOR & WINDOW FRAMES, BOTH SIDES.
3. PROVIDE ADEQUATE BARRIER AGAINST CORROSION BETWEEN DIFFERENT TYPES OF
MATERIALS THAT MAY COME INTO CONTACT.
4. SEE SHEET A2.1 FOR ROOM FINISH SCHEDULE FOR WALL & FLOOR FINISHES.
GENERAL NOTESWINDOW TYPES
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
1
0
:
5
7
P
M
A10.1
DOOR &
WINDOW
SCHEDULES
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
DOOR
NUMBER
DOOR
TYPE
FRAME
TYPE DESCRIPTION WIDTH HEIGHT HEAD DETAIL
JAMB
DETAIL
THRESHOLD
DETAIL
FIRE
RATING HARDWARE REMARKS
Exterior
E1 A A HOLLOW METAL DOOR & FRAME
WITH FULL GLASS
3' - 0" 6' - 8" 7/A10.2 8/A10.2 9/A10.2 PASSAGE W/ CLOSER
E2 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E3 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E4 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E5 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E6 B A HOLLOW METAL DOOR & FRAME 3' - 0" 6' - 8" 7/A10.2 8/A10.2 9/A10.2 60 MIN. STOREROOM W/ CLOSER
E7 A A HOLLOW METAL DOOR & FRAME
WITH FULL GLASS
3' - 0" 6' - 8" 7/A10.2 8/A10.2 9/A10.2 PASSAGE W/ CLOSER
E8 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E9 D B HOLLOW METAL DOOR & FRAME 3' - 0" 6' - 8" 7/A10.2 8/A10.2 9/A10.2 PRIVACY
E10 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E11 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E12 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E13 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E14 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E15 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E16 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E17 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E18 D B HOLLOW METAL DOOR & FRAME 3' - 0" 6' - 8" 7/A10.2 8/A10.2 9/A10.2 PRIVACY
E19 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E20 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E21 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E22 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E23 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E24 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E25 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E26 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E27 D B HOLLOW METAL DOOR & FRAME 3' - 0" 6' - 8" 7/A10.2 8/A10.2 9/A10.2 PRIVACY
E28 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E29 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
E30 C B VINYL SLIDING DOOR & FRAME 6' - 0" 6' - 8" 1/A10.2 2/A10.2 3/A10.2 SLIDING PATIO
Interior
101 E C SOLID CORE WOOD DOOR &
FRAME
3' - 0" 6' - 8" 10/A10.2 11/A10.2 N/A 60 MIN. PASSAGE W/ CLOSER
102 E C SOLID CORE WOOD DOOR &
FRAME
3' - 0" 6' - 8" 10/A10.2 11/A10.2 N/A STOREROOM
104 E C SOLID CORE WOOD DOOR &
FRAME
3' - 0" 6' - 8" 10/A10.2 11/A10.2 N/A 60 MIN. PASSAGE W/ CLOSER
105 E C SOLID CORE WOOD DOOR &
FRAME
3' - 0" 6' - 8" 10/A10.2 11/A10.2 N/A 60 MIN. STOREROOM W/ CLOSER
201 E C SOLID CORE WOOD DOOR &
FRAME
3' - 0" 6' - 8" 10/A10.2 11/A10.2 N/A 60 MIN. PASSAGE W/ CLOSER
203 E C SOLID CORE WOOD DOOR &
FRAME
3' - 0" 6' - 8" 10/A10.2 11/A10.2 N/A 60 MIN. PASSAGE W/ CLOSER
301 E C SOLID CORE WOOD DOOR &
FRAME
3' - 0" 6' - 8" 10/A10.2 11/A10.2 N/A 60 MIN. PASSAGE W/ CLOSER
303 E C SOLID CORE WOOD DOOR &
FRAME
3' - 0" 6' - 8" 10/A10.2 11/A10.2 N/A 60 MIN. PASSAGE W/ CLOSER
B E C SOLID CORE WOOD DOOR &
FRAME
3' - 0" 6' - 8" 10/A10.2 11/A10.2 N/A 20 min. PRIVATE W/ CLOSER
E F D HOLLOW CORE MASONITE DOOR
& FRAME
2' - 8" 6' - 8" 10/A10.2 SIM. 11/A10.2
SIM.
N/A PRIVACY
EE G D DOUBLE HOLLOW CORE
MASONITE DOOR & FRAME WITH
FULL GLASS
5' - 0" 6' - 8" 10/A10.2 SIM. 11/A10.2
SIM.
N/A PRIVACY
Ee F D HOLLOW CORE MASONITE DOOR
& FRAME
3' - 0" 6' - 8" 10/A10.2 SIM. 11/A10.2
SIM.
N/A PRIVACY
F F D HOLLOW CORE MASONITE DOOR
& FRAME
2' - 8" 6' - 8" 10/A10.2 SIM. 11/A10.2
SIM.
N/A PRIVACY
Ff F D HOLLOW CORE MASONITE DOOR
& FRAME
3' - 0" 6' - 8" 10/A10.2 SIM. 11/A10.2
SIM.
N/A PRIVACY
G H D HOLLOW CORE MASONITE DOOR
& FRAME
5' - 8" 6' - 8" 12/A10.2 13/A10.2 N/A BYPASS
J F D HOLLOW CORE MASONITE DOOR
& FRAME
2' - 8" 6' - 8" 10/A10.2 SIM. 11/A10.2
SIM.
N/A PASSAGE
K F D HOLLOW CORE MASONITE DOOR
& FRAME
2' - 4" 6' - 8" 10/A10.2 SIM. 11/A10.2
SIM.
N/A PRIVACY
L F D HOLLOW CORE MASONITE DOOR
& FRAME
2' - 8" 6' - 8" 10/A10.2 SIM. 11/A10.2
SIM.
N/A PRIVACY
DOOR SCHEDULEDOOR TYPE LEGEND
DOOR FRAME TYPES
TYPE
MARK WINDOW FRAME TYPE HEIGHT WIDTH HEAD DETAIL JAMB DETAIL SILL DETAIL REMARKS
A HOLLOW METAL 9' - 0" 4' - 6"
B VINYL FIXED & CASEMENT 1' - 4" 3' - 0"
C <varies> 4' - 0" <varies>
D VINYL FIXED 1' - 4" 6' - 0"
WINDOW SCHEDULE
5' -4"
5' -4"4' -6"
no. description date
All glass and glazing to meet requirements of Chapter 24.
THRESHOLD, SET IN
SEALANT
FLOOR FINISH
PLYWOOD SUBFLOOR
FLOOR JOIST - SEE
STRUCTURAL DRAWINGS
SIDING
FULL THICKNESS
BATT INSULATON
FRAMING - SEE STRUCTURAL
DRAWINGS
5/8" GYPSUM WALL BOARD AIR INFILTRATION BARRIER
CONCRETE DECK OVER DECKING -
SLOPE AWAY FROM BUILDING - SEE
STRUCTURAL DRAWINGS
FLOOR ASSEMBLY - SEE
CR SERIES DRAWINGS
VINYL SLIDING PATIO DOOR - SEE
A10.1 FOR WINDOW AND DOOR
TYPES
SIDING
SHIM AS NECESSARY
FRAMING -SEE STRUCTURAL
DRAWINGS
PLYWOOD SHEATHING -
SEE STRUCTURAL
DRAWINGS
VINYL SLIDING PATIO
DOOR -SEE A10.1 FOR
WINDOW AND DOOR
TYPES
5/8" GYPSUM WALL BOARD
FULL THICKNESS BATT
INSULATION
AIR INFILTRATION
BARRIER
VAPOR BARRIER
MDF TRIM
FULL THICKNESS BATT
INSULATION
PREFINISHED METAL FLASHING
WITH DRIP EDGE
PLYWOOD SHEATHING - SEE
STRUCTURAL DRAWINGS
SIDING
5/8" GYPSUM WALL BOARD
VINYL TRANSOM WINDOW - SEE
A10.1 FOR WINDOW AND DOOR
TYPES
HEADER-SEE
STRUCTURAL DRAWNGS
VAPOR BARRIER
AIR INFILTRATION BARRIER -
EXTEND OVER FLASHING
VINYL SLIDING PATIO DOOR - SEE
A10.1 FOR WINDOW AND DOOR
TYPES
JAMB EXTENTION
MDF TRIM
FULL THICKNESS BATT
INSULATION
PREFINISHED METAL FLASHING
WITH DRIP EDGE
PLYWOOD SHEATHING - SEE
STRUCTURAL DRAWINGS
SIDING
5/8" GYPSUM WALL BOARD
VINYL WINDOW - SEE A10.1 FOR
WINDOW AND DOOR TYPES
HEADER-SEE
STRUCTURAL DRAWNGS
VAPOR BARRIER
AIR INFILTRATION BARRIER -
EXTEND OVER FLASHING
JAMB EXTENTION
SIDING
SHIM AS NECESSARY
FRAMING -SEE STRUCTURAL
DRAWINGS
PLYWOOD SHEATHING -
SEE STRUCTURAL
DRAWINGS
VINYL WINDOW -SEE
A10.1 FOR WINDOW AND
DOOR TYPES
5/8" GYPSUM WALL BOARD
FULL THICKNESS BATT
INSULATION
AIR INFILTRATION
BARRIER
VAPOR BARRIER
FULL THICKNESS BATT
INSULATION
PLYWOOD SHEATHING - SEE
STRUCTURAL DRAWINGS
SIDING - SEE A3.X FOR TYPES AND
LOCATIONS
VAPOR BARRIER
5/8" GYPSUM WALL BOARD
VINYL WINDOW - SEE A10.1 FOR
WINDOW TYPES
SILL
SHIM AS NECESSARY
AIR INFILTRATION BARRIER
MDF TRIM
WOOD DOOR PER DOOR
SCHEDULE - MAINTAIN FIRE
RESISTANCE RATINGS AS
REQUIRED
SHIM AS NECESSARY
MDF TRIM
FULL THICKNESS BATT
INSULATION
WALL CONSTRUCTION PER WALL
TYPES - MAINTAIN FIRE
RESISTANCE RATINGS AS
REQUIRED
MDF TRIM
FULL THICKNESS BATT
INSULATION
PREFINISHED METAL FLASHING
WITH DRIP EDGE
PLYWOOD SHEATHING - SEE
STRUCTURAL DRAWINGS
SIDING
5/8" GYPSUM WALL BOARD
HOLLOW METAL DOOR/WINDOW
AND FRAME - SEE A10.1 FOR
WINDOW AND DOOR TYPES
HEADER-SEE
STRUCTURAL DRAWNGS
VAPOR BARRIER
AIR INFILTRATION BARRIER -
EXTEND OVER FLASHING
HOLLOW METAL DOOR - SEE A10.1
FOR WINDOW AND DOOR TYPES
JAMB EXTENTION
SIDING
SHIM AS NECESSARY
FRAMING -SEE STRUCTURAL
DRAWINGS
PLYWOOD SHEATHING -
SEE STRUCTURAL
DRAWINGS
HOLLOW METAL
DOOR/WINDOW AND
FRAME -SEE A10.1 FOR
WINDOW AND DOOR
TYPES
5/8" GYPSUM WALL BOARD
FULL THICKNESS BATT
INSULATION
AIR INFILTRATION
BARRIER
VAPOR BARRIER
INSULATED HOLLOW METAL DOOR,
PAINTED
EXTERIOR CONCRETE SLAB SET
1/4" BELOW F.F.E
ISOLATION JOINT
ADJUSTABLE DOOR
SWEEP
ALUMINUM THRESHOLD,
SET IN SEALANT
WOOD DOOR PER DOOR
SCHEDULE - MAINTAIN FIRE
RESISTANCE RATINGS AS
REQUIRED
SHIM AS NECESSARY
MDF TRIM
WALL CONSTRUCTION PER WALL
TYPES - MAINTAIN FIRE
RESISTANCE RATINGS AS
REQUIRED
WOOD DOOR PER DOOR
SCHEDULE - MAINTAIN FIRE
RESISTANCE RATINGS AS
REQUIRED
SHIM AS NECESSARY
MDF TRIM
WALL CONSTRUCTION PER WALL
TYPES - MAINTAIN FIRE
RESISTANCE RATINGS AS
REQUIRED
WOOD DOOR PER DOOR
SCHEDULE - MAINTAIN FIRE
RESISTANCE RATINGS AS
REQUIRED
SHIM AS NECESSARY
MDF TRIM
FULL THICKNESS BATT
INSULATION
WALL CONSTRUCTION PER WALL
TYPES - MAINTAIN FIRE
RESISTANCE RATINGS AS
REQUIRED
DOOR HARDWARE
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
1
0
P
M
A10.2
WINDOW AND
DOOR DETAILS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1 1/2" = 1'-0"A10.2
3 SILL @ SLIDING GLASS DOOR
1 1/2" = 1'-0"A10.2
2 JAMB @ SLIDING GLASS DOOR
1 1/2" = 1'-0"A10.2
1 HEAD @ SLIDING GLASS DOOR
1 1/2" = 1'-0"A10.2
4 WINDOW HEAD @ EXTERIOR
1 1/2" = 1'-0"A10.2
5 WINDOW JAMB @ EXTERIOR
1 1/2" = 1'-0"A10.2
6 WINOW SILL @ EXTERIOR
1 1/2" = 1'-0"A10.2
10 HEAD @ INTERIOR DOOR
1 1/2" = 1'-0"A10.2
7 HEAD @ HOLLOW METAL FRAME
1 1/2" = 1'-0"A10.2
8 JAMB @ HOLLOW METAL FRAME
1 1/2" = 1'-0"A10.2
9 THRESHOLD @ HM DOOR
1 1/2" = 1'-0"A10.2
11 JAMB @ INTERIOR DOOR
1 1/2" = 1'-0"A10.2
13 JAMB @ INTERIOR BYPASS DOOR
1 1/2" = 1'-0"A10.2
12 HEAD @ INTERIOR BYPASS DOOR
no. description date
C1 PAINTED, TEXTURED TYPE 'X' GYPSUM WALL BOARD ON FRAMING,
SUSPENDED BELOW C2. USE WATER RESISTANT TYPE 'X' G.W.B. IN SHOWERS.
C2 DOUBLE LAYER, TYPE 'X' GYPSUM WALL BOARD, INSTALLED PER GA
FILE NO. FC 5075. FACE LAYER TO BE TEXTURED AND PAINTED IN ROOMS
WHERE C2 IS EXPOSED.MAINTAIN FIRE RESISTANCE RAITING AT ALL
PENETRATIONS.
RECESSED CAN (EXT. OR INT)
PENDANT MOUNTED DOWNLIGHT
PENDANT MOUNTED DOWNLIGHT
(SMALL)
2' X 2' CEILING PANEL LIGHT
STRIP LIGHT
PENDANT STRIP DOWNLIGHT
2' X 4' CEILING PANEL LIGHT
RECESSED SLOT LIGHT
EMERGENCY FIXTURE
WALL MOUNT STRIP LIGHT
WALL MOUNT FIXTURE
MECHANICAL SUPPLY
NOTE: PLACE SPRINKLER HEAD IN CEILING GRID AS DIAGRAMMED AT LEFT.
PLACE HEAD IN CENTER OF 2X4 OR 2X2 TILE OR IN CENTER OF 1/2 OF A 2X4
OR 2X2 TILE - AS DIRECTED BY ARCHITECT. VERIFY LOCATION OF ALL
SPRINKLER HEADS PRIOR TO FINAL PLACEMENT.
NOTE: SHOULD A CONFLICT OF MECHANICAL AND ELECTRICAL DEVICES OCCUR BETWEEN THE
ARCHITECTURAL REFLECTED CEILING PLAN AND THE MECHANICAL/ ELECTRICAL DRAWINGS,
CONTACT ARCHITECT FOR RESOLUTION
1
A5.3
________1
A5.3
________
B
B
C
C
D
D
E
E
G
G
1 1
________2
A3.1
________1
A3.1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
1
A5.1
________
1
A5.1
________
2
A5.1
________
2
A5.1
________
8 8
2
A5.3
________2
A5.3
________
1
A5.2
________
1
A5.2
________
2
A5.2
________
2
A5.2
________
2
A5.4
________2
A5.4
________
1
A5.5
________1
A5.5
________
1
A5.4
________1
A5.4
________
________1
A11.4
________2
A11.4
1
CR1.4
________
1
CR1.4
________
2
CR1.4
________2
CR1.4
________
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C18' - 0"C1 8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C28' - 11 3/8"C2
8' - 0"C1 8' - 0"C1
8' - 0"C18' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C18' - 0"C1
8' - 0"C2 8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1 8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C18' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
9' - 0"C3
8' - 0"C1
8' - 0"C1
8' - 0"C18' - 0"C1 8' - 11 3/8"C2 8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
9' - 0 7/8"C3
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C18' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 0"C1
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
8' - 0"C1
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10 092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
8' - 0"C1
8' - 0"C1
092900.10
8' - 0"C1
092900.10
230000230000 230000230000
230000
260000260000
260000
260000260000
260000260000 260000260000260000
260000260000
260000260000
260000
260000260000
230000
230000230000
230000
230000
230000
230000
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
1
2
:
4
7
P
M
A11.1
1ST FLOOR
REFLECTED
CEILING PLAN
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1. MAINTAIN ALL FIRE-RESISTANCE RATINGS OF FLOOR/CEILING ASSEMBLIES.
2. LIGHT FIXTURES WHICH OCCUR IN GWB CEILINGS ARE TO BE CENTERED BETWEEN
WALLS AND/OR CASEWORK, UNLESS OTHERWISE NOTED. REFER TO FLOOR PLANS, A1
SERIES, FOR DIMENSIONS AND WALL TYPES.
3. COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS TO AVOID CONFLICT
WITH OBSTRUCTIONS ABOVE CEILING.
4. SUSPENDED GYP. BOARD CEILINGS MAY BE EITHER OF THE FOLLOWING AT
CONTRACTORS OPTION: 5/8" TYPE "X" GWB ON HAT CHANNELS @ 24" O.C., SECURED TO
1 1/2" 'C' CHANNELS @ 48" O.C., SUSPENDED FROM STRUCTURE OR 5/8" TYPE "X" GWB ON
FRAMING AS REQUIRED FOR SPANS, SPACED @ 24" O.C. MAINTAIN ALL FIRE-
RESISTANCE RATINGS OF FLOOR/CEILING ASSEMBLIES LOCATED ABOVE SUSPENDED
GYP. BOARD CEILINGS.
5. THIS BUILDING IS TO BE FULLY SPRINKLERED. SPRINKLER HEAD LOCATIONS AND
QUANTITIES TO BE IN ACCORDANCE WITH NFPA-13R AND ADMINISTRATIVE AUTHORITY.
HEADS TO BE CENTERED IN CEILING TILES, ROOMS OR BETWEEN OTHER CEILING
ELEMENTS, SUCH AS LIGHT FIXTURES, SMOKE DETECTORS, ETC.
6. CEILING ELEVATIONS NOTED ARE ABOVE THE FINISHED FLOOR ELEVATION.
GENERAL NOTES
CEILING TYPES
SYMBOL KEY
1/8" = 1'-0"A11.1
1 1ST FLOOR REFLECTED CEILING PLAN
KEYED NOTES
092900.10 PAINTED,TEXTURED, TYPE X GYPSUM WALL BOARD CEILING
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
260000 ELECTRICAL FIXTURE OR EQUIPMENT - SEE ELECTRICAL
no. description date
1
A5.3
________1
A5.3
________
B
B
C
C
D
D
E
E
G
G
1 1
________1
A3.2
________2
A3.1
________1
A3.1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
________2
A3.2
1
A5.1
________
1
A5.1
________
2
A5.1
________
2
A5.1
________
8 8
2
A5.3
________2
A5.3
________
1
A5.2
________
1
A5.2
________
2
A5.2
________
2
A5.2
________
2
A5.4
________2
A5.4
________
1
A5.5
________1
A5.5
________
1
A5.4
________1
A5.4
________
1
CR1.4
________
1
CR1.4
________
2
CR1.4
________2
CR1.4
________
________1
A11.5
________2
A11.5
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10 092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10 092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10092900.10
230000230000 230000230000
230000
260000260000
260000260000 260000260000260000
260000260000
260000
260000260000
230000230000
230000
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C18' - 0"C1 8' - 0"C1
8' - 11 3/8"C2
9' - 0"C3
8' - 11 3/8"C28' - 11 3/8"C2
8' - 0"C1 8' - 0"C1
8' - 0"C18' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C18' - 0"C1
8' - 0"C1 8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
9' - 0"C3
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1 8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C18' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
9' - 0"C3
8' - 0"C1
8' - 0"C1
8' - 0"C18' - 0"C1 8' - 11 3/8"C2 8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
9' - 0"C3
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C18' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C18' - 0"C1
9' - 0"C3
C1 PAINTED, TEXTURED TYPE 'X' GYPSUM WALL BOARD ON FRAMING,
SUSPENDED BELOW C2. USE WATER RESISTANT TYPE 'X' G.W.B. IN SHOWERS.
C2 DOUBLE LAYER, TYPE 'X' GYPSUM WALL BOARD, INSTALLED PER GA
FILE NO. FC 5075. FACE LAYER TO BE TEXTURED AND PAINTED IN ROOMS
WHERE C2 IS EXPOSED.MAINTAIN FIRE RESISTANCE RAITING AT ALL
PENETRATIONS.
RECESSED CAN (EXT. OR INT)
PENDANT MOUNTED DOWNLIGHT
PENDANT MOUNTED DOWNLIGHT
(SMALL)
2' X 2' CEILING PANEL LIGHT
STRIP LIGHT
PENDANT STRIP DOWNLIGHT
2' X 4' CEILING PANEL LIGHT
RECESSED SLOT LIGHT
EMERGENCY FIXTURE
WALL MOUNT STRIP LIGHT
WALL MOUNT FIXTURE
MECHANICAL SUPPLY
NOTE: PLACE SPRINKLER HEAD IN CEILING GRID AS DIAGRAMMED AT LEFT.
PLACE HEAD IN CENTER OF 2X4 OR 2X2 TILE OR IN CENTER OF 1/2 OF A 2X4
OR 2X2 TILE - AS DIRECTED BY ARCHITECT. VERIFY LOCATION OF ALL
SPRINKLER HEADS PRIOR TO FINAL PLACEMENT.
NOTE: SHOULD A CONFLICT OF MECHANICAL AND ELECTRICAL DEVICES OCCUR BETWEEN THE
ARCHITECTURAL REFLECTED CEILING PLAN AND THE MECHANICAL/ ELECTRICAL DRAWINGS,
CONTACT ARCHITECT FOR RESOLUTION
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
1
2
:
4
8
P
M
A11.2
2ND FLOOR
REFLECTED
CEILING PLAN
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"A11.2
1 2ND FLOOR REFLECTED CEILING PLAN
1. MAINTAIN ALL FIRE-RESISTANCE RATINGS OF FLOOR/CEILING ASSEMBLIES.
2. LIGHT FIXTURES WHICH OCCUR IN GWB CEILINGS ARE TO BE CENTERED BETWEEN
WALLS AND/OR CASEWORK, UNLESS OTHERWISE NOTED. REFER TO FLOOR PLANS, A1
SERIES, FOR DIMENSIONS AND WALL TYPES.
3. COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS TO AVOID CONFLICT
WITH OBSTRUCTIONS ABOVE CEILING.
4. SUSPENDED GYP. BOARD CEILINGS MAY BE EITHER OF THE FOLLOWING AT
CONTRACTORS OPTION: 5/8" TYPE "X" GWB ON HAT CHANNELS @ 24" O.C., SECURED TO
1 1/2" 'C' CHANNELS @ 48" O.C., SUSPENDED FROM STRUCTURE OR 5/8" TYPE "X" GWB ON
FRAMING AS REQUIRED FOR SPANS, SPACED @ 24" O.C. MAINTAIN ALL FIRE-
RESISTANCE RATINGS OF FLOOR/CEILING ASSEMBLIES LOCATED ABOVE SUSPENDED
GYP. BOARD CEILINGS.
5. THIS BUILDING IS TO BE FULLY SPRINKLERED. SPRINKLER HEAD LOCATIONS AND
QUANTITIES TO BE IN ACCORDANCE WITH NFPA-13R AND ADMINISTRATIVE AUTHORITY.
HEADS TO BE CENTERED IN CEILING TILES, ROOMS OR BETWEEN OTHER CEILING
ELEMENTS, SUCH AS LIGHT FIXTURES, SMOKE DETECTORS, ETC.
6. CEILING ELEVATIONS NOTED ARE ABOVE THE FINISHED FLOOR ELEVATION.
GENERAL NOTES
CEILING TYPES
SYMBOL KEY
KEYED NOTES
092900.10 PAINTED,TEXTURED, TYPE X GYPSUM WALL BOARD CEILING
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
260000 ELECTRICAL FIXTURE OR EQUIPMENT - SEE ELECTRICAL
no. description date
1
A5.3
________1
A5.3
________
B
B
C
C
D
D
E
E
G
G
1 1
________1
A3.2
________2
A3.1
________1
A3.1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
________2
A3.2
1
A5.1
________
1
A5.1
________
2
A5.1
________
2
A5.1
________
8 8
2
A5.3
________2
A5.3
________
1
A5.2
________
1
A5.2
________
2
A5.2
________
2
A5.2
________
2
A5.4
________2
A5.4
________
1
A5.5
________1
A5.5
________
1
A5.4
________1
A5.4
________
1
CR1.4
________
1
CR1.4
________
2
CR1.4
________2
CR1.4
________
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1 8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 11 3/8"C2
9' - 0 7/8"C3
8' - 11 3/8"C2
8' - 0"C18' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1 8' - 0"C1
8' - 11 3/8"C28' - 11 3/8"C2
8' - 0"C18' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1 8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
10' - 2"C310' - 2"C3
8' - 11 3/8"C28' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C18' - 0"C1
8' - 11 3/8"C2 8' - 11 3/8"C2
8' - 0"C18' - 0"C1
8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
092900.10
092900.10
092900.10
092900.10092900.10092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10092900.10
092900.10 092900.10
092900.10
092900.10 092900.10
092900.10092900.10
8' - 0"C1 8' - 0"C1
092900.10092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
230000230000
230000230000230000230000
230000230000
8' - 0"C18' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 0"C1
092900.10 092900.10 092900.10
092900.10
092900.10
092900.10092900.10092900.10
092900.10
092900.10
092900.10
092900.10
092900.10092900.10
092900.10092900.10
092900.10092900.10
092900.10092900.10
092900.10
092900.10 092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10092900.10
092900.10
C1 PAINTED, TEXTURED TYPE 'X' GYPSUM WALL BOARD ON FRAMING,
SUSPENDED BELOW C2. USE WATER RESISTANT TYPE 'X' G.W.B. IN SHOWERS.
C2 DOUBLE LAYER, TYPE 'X' GYPSUM WALL BOARD, INSTALLED PER GA
FILE NO. FC 5075. FACE LAYER TO BE TEXTURED AND PAINTED IN ROOMS
WHERE C2 IS EXPOSED.MAINTAIN FIRE RESISTANCE RAITING AT ALL
PENETRATIONS.
RECESSED CAN (EXT. OR INT)
PENDANT MOUNTED DOWNLIGHT
PENDANT MOUNTED DOWNLIGHT
(SMALL)
2' X 2' CEILING PANEL LIGHT
STRIP LIGHT
PENDANT STRIP DOWNLIGHT
2' X 4' CEILING PANEL LIGHT
RECESSED SLOT LIGHT
EMERGENCY FIXTURE
WALL MOUNT STRIP LIGHT
WALL MOUNT FIXTURE
MECHANICAL SUPPLY
NOTE: PLACE SPRINKLER HEAD IN CEILING GRID AS DIAGRAMMED AT LEFT.
PLACE HEAD IN CENTER OF 2X4 OR 2X2 TILE OR IN CENTER OF 1/2 OF A 2X4
OR 2X2 TILE - AS DIRECTED BY ARCHITECT. VERIFY LOCATION OF ALL
SPRINKLER HEADS PRIOR TO FINAL PLACEMENT.
NOTE: SHOULD A CONFLICT OF MECHANICAL AND ELECTRICAL DEVICES OCCUR BETWEEN THE
ARCHITECTURAL REFLECTED CEILING PLAN AND THE MECHANICAL/ ELECTRICAL DRAWINGS,
CONTACT ARCHITECT FOR RESOLUTION
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
1
2
:
4
9
P
M
A11.3
3RD FLOOR
REFLECTED
CEILING PLAN
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"A11.3
1 3RD FLOOR REFLECTED CEILING PLAN
1. MAINTAIN ALL FIRE-RESISTANCE RATINGS OF FLOOR/CEILING ASSEMBLIES.
2. LIGHT FIXTURES WHICH OCCUR IN GWB CEILINGS ARE TO BE CENTERED BETWEEN
WALLS AND/OR CASEWORK, UNLESS OTHERWISE NOTED. REFER TO FLOOR PLANS, A1
SERIES, FOR DIMENSIONS AND WALL TYPES.
3. COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS TO AVOID CONFLICT
WITH OBSTRUCTIONS ABOVE CEILING.
4. SUSPENDED GYP. BOARD CEILINGS MAY BE EITHER OF THE FOLLOWING AT
CONTRACTORS OPTION: 5/8" TYPE "X" GWB ON HAT CHANNELS @ 24" O.C., SECURED TO
1 1/2" 'C' CHANNELS @ 48" O.C., SUSPENDED FROM STRUCTURE OR 5/8" TYPE "X" GWB ON
FRAMING AS REQUIRED FOR SPANS, SPACED @ 24" O.C. MAINTAIN ALL FIRE-
RESISTANCE RATINGS OF FLOOR/CEILING ASSEMBLIES LOCATED ABOVE SUSPENDED
GYP. BOARD CEILINGS.
5. THIS BUILDING IS TO BE FULLY SPRINKLERED. SPRINKLER HEAD LOCATIONS AND
QUANTITIES TO BE IN ACCORDANCE WITH NFPA-13R AND ADMINISTRATIVE AUTHORITY.
HEADS TO BE CENTERED IN CEILING TILES, ROOMS OR BETWEEN OTHER CEILING
ELEMENTS, SUCH AS LIGHT FIXTURES, SMOKE DETECTORS, ETC.
6. CEILING ELEVATIONS NOTED ARE ABOVE THE FINISHED FLOOR ELEVATION.
GENERAL NOTES
CEILING TYPES
SYMBOL KEY
KEYED NOTES
092900.10 PAINTED,TEXTURED, TYPE X GYPSUM WALL BOARD CEILING
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
no. description date
BCD
1
5
3
A
2
4
1
A5.1
________
2
A5.3
________
2
A5.4
________
1
A5.5
________
1
A5.4
________
2
CR1.4
________8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2 8' - 0"C1
8' - 0"C1
8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
092900.10
092900.10 092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10092900.10
092900.10
092900.10 092900.10
092900.10
092900.10
230000
230000 230000
230000
260000260000
260000
260000
EG
1
5
3
F
2
4
2
A5.1
________
2
A5.3
________
1
A5.2
________2
A5.2
________
2
A5.4
________
1
A5.5
________
1
A5.4
________
1
CR1.4
________
2
CR1.4
________
8' - 0"C1
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C18' - 0"C1
8' - 0"C18' - 0"C1 8' - 11 3/8"C2
8' - 0"C1
8' - 0"C2
8' - 11 3/8"C2
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 0"C1
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
260000260000
260000
230000
230000
230000
230000
RECESSED CAN (EXT. OR INT)
PENDANT MOUNTED DOWNLIGHT
PENDANT MOUNTED DOWNLIGHT
(SMALL)
2' X 2' CEILING PANEL LIGHT
STRIP LIGHT
PENDANT STRIP DOWNLIGHT
2' X 4' CEILING PANEL LIGHT
RECESSED SLOT LIGHT
EMERGENCY FIXTURE
WALL MOUNT STRIP LIGHT
WALL MOUNT FIXTURE
MECHANICAL SUPPLY
NOTE: PLACE SPRINKLER HEAD IN CEILING GRID AS DIAGRAMMED AT LEFT.
PLACE HEAD IN CENTER OF 2X4 OR 2X2 TILE OR IN CENTER OF 1/2 OF A 2X4
OR 2X2 TILE - AS DIRECTED BY ARCHITECT. VERIFY LOCATION OF ALL
SPRINKLER HEADS PRIOR TO FINAL PLACEMENT.
NOTE: SHOULD A CONFLICT OF MECHANICAL AND ELECTRICAL DEVICES OCCUR BETWEEN THE
ARCHITECTURAL REFLECTED CEILING PLAN AND THE MECHANICAL/ ELECTRICAL DRAWINGS,
CONTACT ARCHITECT FOR RESOLUTION
C1 PAINTED, TEXTURED TYPE 'X' GYPSUM WALL BOARD ON FRAMING,
SUSPENDED BELOW C2. USE WATER RESISTANT TYPE 'X' G.W.B. IN SHOWERS.
C2 DOUBLE LAYER, TYPE 'X' GYPSUM WALL BOARD, INSTALLED PER GA
FILE NO. FC 5075. FACE LAYER TO BE TEXTURED AND PAINTED IN ROOMS
WHERE C2 IS EXPOSED.MAINTAIN FIRE RESISTANCE RAITING AT ALL
PENETRATIONS.
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
1
2
:
4
9
P
M
A11.4
1ST FLOOR UNIT
REFLECTED
CEILING PLANS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/4" = 1'-0"A11.4
1 1ST FLOOR UNIT 1 AND 2 REFLECTED CEILING PLAN
1/4" = 1'-0"A11.4
2 1ST FLOOR UNIT 3 REFLECTED CEILING PLAN
1. MAINTAIN ALL FIRE-RESISTANCE RATINGS OF FLOOR/CEILING ASSEMBLIES.
2. LIGHT FIXTURES WHICH OCCUR IN GWB CEILINGS ARE TO BE CENTERED BETWEEN
WALLS AND/OR CASEWORK, UNLESS OTHERWISE NOTED. REFER TO FLOOR PLANS, A1
SERIES, FOR DIMENSIONS AND WALL TYPES.
3. COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS TO AVOID CONFLICT
WITH OBSTRUCTIONS ABOVE CEILING.
4. SUSPENDED GYP. BOARD CEILINGS MAY BE EITHER OF THE FOLLOWING AT
CONTRACTORS OPTION: 5/8" TYPE "X" GWB ON HAT CHANNELS @ 24" O.C., SECURED TO
1 1/2" 'C' CHANNELS @ 48" O.C., SUSPENDED FROM STRUCTURE OR 5/8" TYPE "X" GWB ON
FRAMING AS REQUIRED FOR SPANS, SPACED @ 24" O.C. MAINTAIN ALL FIRE-
RESISTANCE RATINGS OF FLOOR/CEILING ASSEMBLIES LOCATED ABOVE SUSPENDED
GYP. BOARD CEILINGS.
5. THIS BUILDING IS TO BE FULLY SPRINKLERED. SPRINKLER HEAD LOCATIONS AND
QUANTITIES TO BE IN ACCORDANCE WITH NFPA-13R AND ADMINISTRATIVE AUTHORITY.
HEADS TO BE CENTERED IN CEILING TILES, ROOMS OR BETWEEN OTHER CEILING
ELEMENTS, SUCH AS LIGHT FIXTURES, SMOKE DETECTORS, ETC.
6. CEILING ELEVATIONS NOTED ARE ABOVE THE FINISHED FLOOR ELEVATION.
GENERAL NOTESSYMBOL KEY CEILING TYPES KEYED NOTES
092900.10 PAINTED,TEXTURED, TYPE X GYPSUM WALL BOARD CEILING
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
260000 ELECTRICAL FIXTURE OR EQUIPMENT - SEE ELECTRICAL
no. description date
EG
1
5
3
F
2
4
2
A5.3
________
1
A5.2
________2
A5.2
________
2
A5.4
________
1
A5.5
________
1
A5.4
________
1
CR1.4
________
2
CR1.4
________
8' - 0"C1
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C18' - 0"C1
8' - 0"C18' - 0"C1 8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 11 3/8"C2
9' - 0"C3
8' - 0"C1
8' - 0"C1
8' - 0"C1
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
260000260000
230000
230000
230000
BCD
1
5
3
A
2
4
1
A5.1
________
2
A5.4
________
1
A5.5
________
1
A5.4
________
2
CR1.4
________8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
8' - 11 3/8"C2
8' - 11 3/8"C2 8' - 0"C1
8' - 0"C1
8' - 0"C1
9' - 0"C3
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 11 3/8"C2
8' - 0"C1
8' - 0"C1
092900.10
092900.10 092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10
092900.10092900.10
092900.10
092900.10 092900.10
092900.10
092900.10
230000
230000 230000
230000
260000260000260000
RECESSED CAN (EXT. OR INT)
PENDANT MOUNTED DOWNLIGHT
PENDANT MOUNTED DOWNLIGHT
(SMALL)
2' X 2' CEILING PANEL LIGHT
STRIP LIGHT
PENDANT STRIP DOWNLIGHT
2' X 4' CEILING PANEL LIGHT
RECESSED SLOT LIGHT
EMERGENCY FIXTURE
WALL MOUNT STRIP LIGHT
WALL MOUNT FIXTURE
MECHANICAL SUPPLY
NOTE: PLACE SPRINKLER HEAD IN CEILING GRID AS DIAGRAMMED AT LEFT.
PLACE HEAD IN CENTER OF 2X4 OR 2X2 TILE OR IN CENTER OF 1/2 OF A 2X4
OR 2X2 TILE - AS DIRECTED BY ARCHITECT. VERIFY LOCATION OF ALL
SPRINKLER HEADS PRIOR TO FINAL PLACEMENT.
NOTE: SHOULD A CONFLICT OF MECHANICAL AND ELECTRICAL DEVICES OCCUR BETWEEN THE
ARCHITECTURAL REFLECTED CEILING PLAN AND THE MECHANICAL/ ELECTRICAL DRAWINGS,
CONTACT ARCHITECT FOR RESOLUTION
C1 PAINTED, TEXTURED TYPE 'X' GYPSUM WALL BOARD ON FRAMING,
SUSPENDED BELOW C2. USE WATER RESISTANT TYPE 'X' G.W.B. IN SHOWERS.
C2 DOUBLE LAYER, TYPE 'X' GYPSUM WALL BOARD, INSTALLED PER GA
FILE NO. FC 5075. FACE LAYER TO BE TEXTURED AND PAINTED IN ROOMS
WHERE C2 IS EXPOSED.MAINTAIN FIRE RESISTANCE RAITING AT ALL
PENETRATIONS.
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
2
3
P
M
A11.5
2ND & 3RD
FLOOR UNIT
REFLECTED
CEILING PLANS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/4" = 1'-0"A11.5
1 2ND &3RD FLOOR UNIT 3 REFLECTED CEILING PLAN
1/4" = 1'-0"A11.5
2 2ND & 3RD FLOOR UNITS 1 AND 2 REFLECTED CEILING PLAN
1. MAINTAIN ALL FIRE-RESISTANCE RATINGS OF FLOOR/CEILING ASSEMBLIES.
2. LIGHT FIXTURES WHICH OCCUR IN GWB CEILINGS ARE TO BE CENTERED BETWEEN
WALLS AND/OR CASEWORK, UNLESS OTHERWISE NOTED. REFER TO FLOOR PLANS, A1
SERIES, FOR DIMENSIONS AND WALL TYPES.
3. COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS TO AVOID CONFLICT
WITH OBSTRUCTIONS ABOVE CEILING.
4. SUSPENDED GYP. BOARD CEILINGS MAY BE EITHER OF THE FOLLOWING AT
CONTRACTORS OPTION: 5/8" TYPE "X" GWB ON HAT CHANNELS @ 24" O.C., SECURED TO
1 1/2" 'C' CHANNELS @ 48" O.C., SUSPENDED FROM STRUCTURE OR 5/8" TYPE "X" GWB ON
FRAMING AS REQUIRED FOR SPANS, SPACED @ 24" O.C. MAINTAIN ALL FIRE-
RESISTANCE RATINGS OF FLOOR/CEILING ASSEMBLIES LOCATED ABOVE SUSPENDED
GYP. BOARD CEILINGS.
5. THIS BUILDING IS TO BE FULLY SPRINKLERED. SPRINKLER HEAD LOCATIONS AND
QUANTITIES TO BE IN ACCORDANCE WITH NFPA-13R AND ADMINISTRATIVE AUTHORITY.
HEADS TO BE CENTERED IN CEILING TILES, ROOMS OR BETWEEN OTHER CEILING
ELEMENTS, SUCH AS LIGHT FIXTURES, SMOKE DETECTORS, ETC.
6. CEILING ELEVATIONS NOTED ARE ABOVE THE FINISHED FLOOR ELEVATION.
GENERAL NOTESSYMBOL KEY CEILING TYPES KEYED NOTES
092900.10 PAINTED,TEXTURED, TYPE X GYPSUM WALL BOARD CEILING
230000 MECHANICAL FIXTURE OR EQUIPMENT - SEE MECHANICAL
260000 ELECTRICAL FIXTURE OR EQUIPMENT - SEE ELECTRICAL
no. description date
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
1
:
5
1
:
2
4
P
M
A12.1
PRODUCT
SPECIFICATIONS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
KEYED NOTE NO.: 072413 -EXTERIOR INSULATION FINISH SYSTEM (EIFS) -DRYVIT OUTSULATION
SYSTEM -OR EQUAL
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: DRYVIT OUTSULATION SYSTEM
DESCRIPTION: EXTERIOR INSULATION FINISH SYSTEM (EIFS)
MANUFACTURER: DRYVIT
COLOR: TO BE DETERMINED
DIMENSIONS: N/A
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://www.dryvit.com/systems/continuous-insulation/outsulation/
1. AQUAFLASH(R) FLASHING SYSTEM
2. ADHESIVE
3. PRE-BASED STARTER BOARD
4. EPS CONTINUOUS INSULATION
5. BASE COAT
6. REINFORCING MESH
7. FINISH
KEYED NOTE NO.: 066113.02 -CULTURED MARBLE FABRICATIONS -WALL SURROUNDS
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: WHITEWATER
DESCRIPTION: CULTURED MARBLE WALL SURROUND
MANUFACTURER: WHITEWATER
COLOR: TYVARIAN SERIES 1 -TO BE DETERMINED
DIMENSIONS: REFER TO DRAWINGS FOR LOCATIONS, QUANTITIES, AND DIMENSIONS.
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://whitewaterinc.com/available-colors-2/
KEYED NOTE NO.: 066113.10 -FIBERGLASS REINFORCED ACRYLIC/ABS -SHOWER BASE
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: DREAMLINE SLIM LINE 36 IN. D X 60 IN. W CENTER DRAIN SINGLE THRESHOLD SHOWER
BASE
DESCRIPTION: FIBERGLASS REINFORCED ACRYLIC/ABS SHOWER BASE
MANUFACTURER: DREAMLINE
COLOR: TO BE DETERMINED.
DIMENSIONS: REFER TO DRAWINGS FOR LOCATIONS, QUANTITIES, AND DIMENSIONS.
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://dreamline.com/shower-bases/dreamline-slimline-single-threshold-shower-base_dlt-1130600.html
KEYED NOTE NO.: 087100 -DOOR HARDWARE -SCHLAGE LATITUDE LEVER WITH ROUND TRIM
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: SCHLAGE LATITUDE WITH ROUND TRIM
DESCRIPTION: DOOR HARDWARE LEVER WITH ROUND TRIM
MANUFACTURER: SCHLAGE
COLOR: BLACK
DIMENSIONS: REFER TO DRAWINGS FOR LOCATIONS, QUANTITIES, AND DIMENSIONS.
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://www.schlage.com/en/home/products/FC21LATFFFKIN.html
KEYED NOTE NO.: 123661.19 -QUARTZ AGGLOMERATE COUNTERTOPS
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: QUARTZ COUNTERTOP
DESCRIPTION: QUARTZ COUNTERTOP
MANUFACTURER: WHITEWATER
COLOR: SERIES 1 QUARTZ COLORS
DIMENSIONS: REFER TO DRAWINGS FOR LOCATIONS, QUANTITIES, AND DIMENSIONS.
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://whitewaterinc.com/kitchen-countertops/
KEYED NOTE NO.: 096513 -RESILIENT BASE
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: RESILIENT BASE
DESCRIPTION: CONTOURED RESILIENT BASE
MANUFACTURER: TARKETT/JOHNSONITE
COLOR: TO BE DETERMINED
DIMENSIONS: REFER TO DRAWINGS FOR LOCATIONS, QUANTITIES, AND DIMENSIONS.
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://commercial.tarkett.com/en_US/collection-C000490-millwork-wall-finishing-system
KEYED NOTE NO.: 064116 -PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
DESCRIPTION: THERMALLY FUSED LAMINATE (TFL) CLAD CABINETS
MANUFACTURER: WILSONART
COLOR: TO BE DETERMINED
DIMENSIONS: REFER TO DRAWINGS FOR LOCATIONS, QUANTITIES, AND DIMENSIONS.
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://www.wilsonart.com/tfl-panels
KEYED NOTE NO.: 085313 -VINYL WINDOWS AND DOORS
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: TRINSIC SERIES V300 VINYL WINDOWS AND DOORS
DESCRIPTION: VINYL WINDOWS AND DOORS
MANUFACTURER: MILGARD
COLOR: BLACK EXTERIOR, BLACK INTERIOR
DIMENSIONS: REFER TO THE DRAWINGS
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://www.milgard.com/windows/trinsic-series
KEYED NOTE NO.: 074213 -METAL WALL PANELS
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: METAL WALL PANELS
DESCRIPTION: 12" WIDE FLAT METAL WALL PANELS
MANUFACTURER: METAL SALES
COLOR: TO BE DETERMINED
DIMENSIONS: REFER TO DRAWINGS FOR LOCATIONS, QUANTITIES, AND DIMENSIONS.
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://www.metalsales.us.com/products/tlc-1/
KEYED NOTE NO.: 074643.13 -ENGINEERED WOOD SIDING
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: ENGINEERED WOOD SIDING
DESCRIPTION: CEDAR TEXTURED LAP SIDING
MANUFACTURER: LP BUILDING SOLUTIONS
COLOR: TO BE DETERMINED
DIMENSIONS: REFER TO DRAWINGS FOR LOCATIONS, QUANTITIES, AND DIMENSIONS.
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://lpcorp.com/products/exterior/siding-trim/products/lap-siding
KEYED NOTE NO.: 074646 -FIBER CEMENT SIDING
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: FIBER CEMENT SIDING
DESCRIPTION: FIBER CEMENT PANEL SIDING -FINE SAND TEXTURE
MANUFACTURER: JAMES HARDIE
COLOR: TO BE DETERMINED
DIMENSIONS: REFER TO DRAWINGS FOR LOCATIONS, QUANTITIES, AND DIMENSIONS.
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://www.jameshardie.com/products/hardie-architectural-collection
KEYED NOTE NO.: 074646.13 -FIBER CEMENT SIDING ALUMINUM TRIM
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: FIBER CEMENT SIDING ALUMINUM TRIM
DESCRIPTION: MISCELLANEOUS TRIM PROFILES FOR FIBER CEMENT PANEL SIDING AS REQUIRED
MANUFACTURER: FLANNERY, INC.
COLOR: TO BE DETERMINED
DIMENSIONS: REFER TO DRAWINGS FOR LOCATIONS, QUANTITIES, AND DIMENSIONS.
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://flannerytrim.com/product-category/exterior-trim/cement-panel-trim/
KEYED NOTE NO.: 081433.10 -2-PANEL HOLLOW CORE MASONITE DOORS
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: 2 PANEL HOLLOW CORE MASONITE DOORS
DESCRIPTION: 2 SQUARE PANEL HOLLOW CORE MASONITE DOORS
MANUFACTURER: MASONITE
COLOR: TO BE DETERMINED
DIMENSIONS: REFER TO THE DRAWINGS
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://residential.masonite.com/products/door/interior/2-panel-square/LxMG8l
KEYED NOTE NO.: 081433.05 -2-PANEL MDF FIRE RATED DOOR
DESIGN STANDARD -SUBSTITUTIONS BY REQUEST ONLY
ITEM NAME: 2-PANEL MDF FIRE RATED DOOR
DESCRIPTION: 2-PANEL MDF FIRE RATED DOOR 20 MIN. AND 60 MIN. SEE SCHEDULE
MANUFACTURER: SIMPSON
COLOR: TO BE DETERMINED
DIMENSIONS: REFER TO THE DRAWINGS
NOTES:
1. REFER TO DRAWINGS FOR LOCATIONS AND QUANTITIES.
2. ALL QUANTITIES AND SIZES TO BE VARIFIED BY CONTRACTOR PRIOR TO MANUFACTURING.
3. SHOP DRAWINGS AND SAMPLES TO BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR
TO MANUFACTURING.
4. ALL MATERIALS TO BE SUITABLE FOR USE IN THE DESIGNATED LOCATION.
5. ALL MATERIALS AND FINISHED PRODUCT MUST MEET ALL LOCAL CODES,UL LISTINGS AND FIRE
RATINGS WHERE APPLICABLE.
6. GPC ARCHITECTS DOES NOT WARRANTY MATERIALS AND PRODUCTS, NOR DOES GPC
ARCHITECTS IN ANY WAY WARRANTY THE WORK OF THE CONTRACTOR OR SUB-CONTRACTORS.
https://www.simpsondoor.com/door-series/interior/infinity-doors/
no. description date
City of Rexburg
Special inspector needs to be identified.
Need to have engineered truss plans that are also approved by design professional.
F
2
F
1
F
1
F
2
F
2
F
1
F
1
F
3
EH
1
EH
2 EH
2
EF
1
EF
1 EF
1 EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1 EF
1
EF
1
EF
1EF
1
NOTE:
SEE LARGE SCALE TYPICAL MECHANICAL FLOOR
PLANS ON SHEET M2.0 FOR EQUIPMENT
AND DUCTWORK SERVING EACH INDIVIDUAL
CONDO. TYPE.
108A
EF
1
107E
107L
107C
107A
107B
105A
105B 103B
103A
103E
105E
105G 103G
105F 103F
107K
101B
101A
101F
101E
101C
101L
101
103
104
108E
108G 108C
108B
108K
108N
108L108F
106G
106E
106F 104F
106C 104C
104A104B106B106A
104E 102L
102C
102E
102H
102A102B
UNIT 2
102
TYPE A
UNIT 1
106
TYPE B
UNIT 1
104
TYPE A
UNIT 3
108
TYPE A
UNIT 2
101
TYPE B
UNIT 1
105
TYPE B
UNIT 1
103
TYPE B
UNIT 2
107
TYPE B
G
G
F
F
E
E
D
D
C
C
B
B
A
A
10 10
9 9
8 8
7 7
6 6
5 5
4 4
3 3
2 2
1 1
Apr 18, 2022 PHONE:
1355 EAST CENTER
POCATELLO, IDAHO 83201
ESA JOB NUMBER:
FAX:(208) 233-0529
(208) 233-0501
EMAIL:esa@engsystems.com
21147
Engineered
Systems
Associates
GD
A H
S
P-18184
TA
DIAVD
S
DTEO
L.
I
H NAF
S
R
E
P R O FN
E SGI EERT
AISON L E
NEO
I
R
E
E
N
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
3
3
:
2
4
P
M
M1.1
1ST LEVEL
MECHANICAL
PLAN
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"1 Mechanical 1st Floor Plan
no. description date
B
B
C
C
D
D
E
E
G
G
1 1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
8 8
F
2
F
1
F
1
F
2
F
2
F
1
F
1
F
3
EF
1
EF
1 EF
1 EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1EF
1
NOTE:
SEE LARGE SCALE TYPICAL MECHANICAL FLOOR
PLANS ON SHEET M2.0 FOR EQUIPMENT
AND DUCTWORK SERVING EACH INDIVIDUAL
CONDO. TYPE.
207E
207L 205E 203E 201L
201E
201A203A201B205A207A207B
203
202
201
202A
202B204A204B206B206A
206E 204E 202L
202E
208A
208E
208L
208B
208C
208K
208N
UNIT 2
202
UNIT 1
206
UNIT 1
204
UNIT 3
208
UNIT 2
201
UNIT 1
205
UNIT1
203
UNIT 2
207
G
G
F
F
E
E
D
D
C
C
B
B
A
A
10 10
9 9
8 8
7 7
6 6
5 5
4 4
3 3
2 2
1 1
Apr 18, 2022 PHONE:
1355 EAST CENTER
POCATELLO, IDAHO 83201
ESA JOB NUMBER:
FAX:(208) 233-0529
(208) 233-0501
EMAIL:esa@engsystems.com
21147
Engineered
Systems
Associates
GD
A H
S
P-18184
TA
DIAVD
S
DTEO
L.
I
H NAF
S
R
E
P R O FN
E SGI EERT
AISON L E
NEO
I
R
E
E
N
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
3
3
:
2
5
P
M
M1.2
2ND LEVEL
MECHANICAL
PLAN
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"1 Mechanical 2nd Floor Plan
no. description date
B
B
C
C
D
D
E
E
G
G
1 1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
8 8
F
2
F
1
F
1
F
2
F
2
F
1
F
1
F
3
EH
2
EH
2
EF
1
EF
1 EF
1 EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1
EF
1EF
1
NOTE:
SEE LARGE SCALE TYPICAL MECHANICAL FLOOR
PLANS ON SHEET M2.0 FOR EQUIPMENT
AND DUCTWORK SERVING EACH INDIVIDUAL
CONDO. TYPE.
307E 307L 305E 303E 301L
301E
301A303A303B301B305B305A307B
307A
303
302
301
302A302B
304A304B306B306A308B308A
308E
308F
308L
308C
308K
308N 306E
306C
306F 304F
304C
304E 302L
302K
302E
302F
308G
UNIT 2
302
UNIT 1
306
UNIT 1
304
UNIT 3
308
UNIT 2
301
UNIT 1
305
UNIT 1
303
UNIT 2
307
G
G
F
F
E
E
D
D
C
C
B
B
A
A
10 10
9 9
8 8
7 7
6 6
5 5
4 4
3 3
2 2
1 1
Apr 18, 2022 PHONE:
1355 EAST CENTER
POCATELLO, IDAHO 83201
ESA JOB NUMBER:
FAX:(208) 233-0529
(208) 233-0501
EMAIL:esa@engsystems.com
21147
Engineered
Systems
Associates
GD
A H
S
P-18184
TA
DIAVD
S
DTEO
L.
I
H NAF
S
R
E
P R O FN
E SGI EERT
AISON L E
NEO
I
R
E
E
N
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
3
3
:
2
6
P
M
M1.3
3RD LEVEL
MECHANICAL
PLAN
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/8" = 1'-0"1 Mechanical 3rd Floor Plan
no. description date
D
D
E
E
6 6
10 10
7 7
9 9
8 8
EF
1
F
1
DRYER VENT WALL CAP
TYP. WALL CAP
4"ø EA
8"ø SA
D-1
40
SR-1
200
SR-2
360
R-1
14"x8" RA
14
"
x
8
"
S
A
14
"
x
8
"
R
A
4"ø SA
12"x6" SA
12
"
x
6
"
S
A
4"
ø
E
A
4"
ø
E
A
12"x10" SA
12"x10" SA
T
M. BEDROOM
LIVING KITCHEN
M. BATHROOM
E
E
D
D
10 10
9 9
8 8
7 7
6 6
E
E
10 10
F
F
7 7
9 9
8 8
EF
1
EF
1
EF
1
TYP. WALL CAP
DRYER VENT WALL CAP
F
2
4"ø SA
4"ø SA
8"ø SA
8"ø SA
20
"
x
8
"
S
A
2
0
"
x
8
"
S
A
20
"
x
8
"
R
A
SR-1
175
SR-1
240
SR-1
245
D-1
50 D-1
40
SR-1
150
R-2
4"ø EA
4"ø EA
8"
ø
S
A
4"
ø
E
A
TYP. WALL CAP
14"x14" SA
14"x14" RA
T
M. BEDROOM
BEDROOM 1
KITCHEN
LIVING
BATHROOM 1
F
F
E
E
10 10
9 9
8 8
7 7
Apr 18, 2022 PHONE:
1355 EAST CENTER
POCATELLO, IDAHO 83201
ESA JOB NUMBER:
FAX:(208) 233-0529
(208) 233-0501
EMAIL:esa@engsystems.com
21147
Engineered
Systems
Associates
GD
A H
S
P-18184
TA
DIAVD
S
DTEO
L.
I
H NAF
S
R
E
P R O FN
E SGI EERT
AISON L E
NEO
I
R
E
E
N
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
3
3
:
2
6
P
M
M2.0
LARGE SCALE
MECH. PLANS
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/4" = 1'-0"1 1 BED LARGE SCALE MECH PLAN
1/4" = 1'-0"2 2 BED LARGE SCALE MECH PLAN
PLAN NOTES:
INSTALL FURNACE ON 2'-6" HIGH STAND. REFER TO STRUCTURAL DWGS.
MOUNT PROGRAMMABLE THERMOSTAT ON WALL AND RUN 5 CONDUCTOR
THERMOSTAT WIRE TO FURNACE.
PROVIDE AND INSTALL DRYER WALL BOX IN WALL. DRYER BOX TO BE
COMPLETE WITH 4"∅DUCT UP IN WALL THRU JOISTS TO WALL CAP.
REFER TO DETAIL ON SHEET M2.2 FOR TYPICAL DRYER BOX INSTALLATION.
INSTALL SELF-CONTAINED HVAC UNIT AS SPECIFIED IN FURNACE ROOM.
MAINTAIN AS MUCH CLEARANCE IN FRONT OF UNIT AS POSSIBLE. REFER
TO PLUMBING DRAWINGS FOR CONNECTION TO GAS PIPING &
CONDENSATE DRAIN PIPED TO FLOOR DRAIN. PROVIDE EXTENSION ON
COMBUSTION DISCHARGE AS REQUIRED TO MOUNT AT UPPER PORTION
OF LOUVER. MOUNT FURNACE ON PLATFORM AS PER MFG.
RECOMMENDATIONS.
ARCHITECTURAL LOUVER FURNISHED WITH SELF-CONTAINED HVAC UNITS.
PROVIDE SLEEVE THRU WALL AS REQUIRED FOR GRILLES. COORDINATE
GRILLE LOCATION WITH UNIT AND PIPING. SEAL ALL AROUND GRILLES.
EXTEND COMBUSTION DISCHARGE TO UPPER SECTION OF GRILLE. MOUNT
UPPER GRILLE SECTION WITH BLADE POINTING UPWARD AND LOWER
GRILLE SECTION WITH BLADES POINTING DOWNWARD AS RECOMMENDED
BY MANUFACTURER.
1
2
3
4
5
1
1
2
2
3
3
4
4 5
5
no. description date
E
E
G
G
1 1
5 5
6 6
3 3
F
F
7 7
2 2
4 4
EF
1
EF
1
EF
1
F
3TYP. WALL CAP
4"ø SA
14"x14" SA
14"x14" RA
4"ø EA
4"ø EA
8"ø SA 8"ø SA
8"ø SA
8"ø SA
DROP
4" DIA. DRYER VENT
IN JOIST SPACE
14
"
x
1
0
"
S
A
2
0
"
x
1
0
"
S
A
20
"
x
1
0
"
R
A
4" DIA. EXHAUST
IN JOIST SPACE
DROP
4"
ø
E
A
SR-1
250
SR-1
165
SR-1
165
SR-1
250
SR-1
250
D-1
45
4"ø SA
D-1
50
R-3T
EH
2
EH
1
EF
1
4"ø EA
TYP. WALL CAP
1ST FLOOR STAIR
B
1ST FLOOR
COORIDOR
LIVING
KITCHEN
BEDROOM 2
BEDROOM 1
M. BEDROOM
M. BATHROOM
M. CLOSET
JANITOR
G
G
F
F
E
E
7 7
6 6
5 5
4 4
3 3
2 2
1 1
Apr 18, 2022 PHONE:
1355 EAST CENTER
POCATELLO, IDAHO 83201
ESA JOB NUMBER:
FAX:(208) 233-0529
(208) 233-0501
EMAIL:esa@engsystems.com
21147
Engineered
Systems
Associates
GD
A H
S
P-18184
TA
DIAVD
S
DTEO
L.
I
H NAF
S
R
E
P R O FN
E SGI EERT
AISON L E
NEO
I
R
E
E
N
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
3
3
:
2
6
P
M
M2.1
LARGE SCALE
MECH. PLANS
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
1/4" = 1'-0"1 3 BED LARGE SCALE MECH PLAN
1 4
2
3
5
no. description date
A
FLOOR
1 HR FIRE RATED CEILING
4" HOSE CLAMP DRYER
4" FLEXIBLE
DRYER VENT HOSE
DRYER VENT HOSE
A
4" FLEXIBLE
DUCT UP IN WALL
4" HOSE CLAMP
4"∅
RISE METAL 4"∅ DUCT
UP IN WALL
NOTE:
1-
2-
4" HOSE CLAMP
OUTSIDE WALL
BACK-DRAFT
DAMPER
WALL EXHAUST CAP
SEAL AROUND METAL DRYER
VENT WITH WATER-PROOF
CAULKING ON BOTH SIDES
OF WALL.
ALL DUCTWORK TO BE METAL NO
FLEX DUCT ALLOWED
WALL CAP
CEILING GRILLE
CEILING
EXHAUST FAN
(SEE PLAN FOR SIZE)
EXHAUST DUCT
CABINET
INSULATED
FAN ASSEMBLY
NO SCALE
BACKDRAFT DAMPER
METAL DUCT &
NO PROJECTIONS SUCH AS SCREWS OF
SHEET METAL CORNERS IN DUCTWORK OR AT
ELBOWS ARE ALLOWED.
MAXIMUM EQUIVALENT DUCT LENGTH IS 25'-0"
INCLUDING 5'-0" REDUCTION FOR EACH 90°
ELBOW.
PROVIDE 4"Ø HOSE
CONNECTION AT 4" AFF.
EXTEND THRU WALL 2"
MINIMUM FOR DRYER
CONNECITON.
SYM.TYPE REMARKSCHAR.MCASPE
NATURAL GAS
INPUT OUTPUT L.A.T.E.A.T.GAS
TYPE LIQUID SUCTION C.D. NAT GAS INTAKE EXHAUST
PIPING SIZESDX COOLING COIL
B.T.U. E.A.T. L.A.T.
C.F.M.MAX. P.D.SPEED @ ELEV.
1
F
UPFLOW 24,000 NANA55°FNAT 3/4"
MAGIC PAK MODEL 48MGE4-11-241NP1 WITH ARCHITECTURAL
LOUVER TO MATCH UNIT.31,48838,40048,00013.2 65°F208/60/1 105°F.50"900 75°F .25"55°FM-HIGH 3/4"NA NA
MOCP
20.02
F
UPFLOW 36,000 NANA55°FNAT 3/4"
MAGIC PAK MODEL 60MGE4-11-361NP1 WITH ARCHITECTURAL
LOUVER TO MATCH UNIT.39,00048,00060,00023.9 65°F208/60/1 105°F.50"1175 75°F .25"55°FHIGH 3/4"NA NA35.03
F
UPFLOW 12,000 NANA55°FNAT 3/4"
MAGIC PAK MODEL 36MGE4-11-121NP1 WITH ARCHITECTURAL
LOUVER TO MATCH UNIT.23,04028,80036,0007.6 65°F208/60/1 105°F.50"600 75°F .25"55°FM-HIGH 3/4"NA NA15.0
REMARKSCONTROLCHARKWBTUTYPESYM.
1
EH WALL MOUNTED 208/60/1 INTEGRAL
QMARK MODEL CWH3208 WALL HEATER WITH RECESSED
MOUNTING BRACKET AND INTEGRAL T-STAT
2
EH WALL MOUNTED 120/60/12.06,830 INTEGRAL
QMARK MODEL HT1502SS WALL HEATER WITH RECESSED
MOUNTING BRACKET AND INTEGRAL T-STAT
S.P.E.
1
EF
SYM.TYPE C.F.M.CONTROLCHAR.H.P.R.P.M.REMARKS
CEILING MOUNTED 100 1/60.25 120/60/1 760
AIR KING FV WITH 4"∅ DUCT & BACKDRAFT DAMPER, CEILI NG MOUNTED
EXHAUST GRILLE AND WALL CAP.
SWITCH
SEE ELEC.
THROWSYM.SIZE CONSTR.CFM FINISH F.D.O.B.REMARKSA
A
SR-1 ACCORD MODEL 222 WITH 2-WAY DEFLECTION. MOUNT IN SIDEWALL, REFER
TO PLANS FOR HEIGHT. PROVIDE TRANSITION BOOT.12 x 8 140-250 STEEL WHITE NO YES2 WAY
CD-1 10 x 4 50-120 STEEL WHITE NO YES
ACCORD MODEL 222 WITH 2-WAY DEFLECTION. MOUNT IN CEILING. PROVIDE
TRANSITION BOOT.2 WAY
N.C.
20
20
SR-2 ACCORD MODEL 222 WITH 2-WAY DEFLECTION. MOUNT IN SIDEWALL, REFER
TO PLANS FOR HEIGHT. PROVIDE TRANSITION BOOT.20 x 6 300-400 STEEL WHITE NO YES2 WAY 20
R-1 16 x16 600 STEEL WHITE NO NO---
ACCORD MODEL 500. MOUNT IN CEILING IN LOCATION SHOWN ON PLANS.25
R-2 20 x 20 900 STEEL WHITE NO NO---25
R-3 24 x 24 1100-1200 STEEL WHITE NO NO---25
2.06,830
ACCORD MODEL 500. MOUNT IN CEILING IN LOCATION SHOWN ON PLANS.
ACCORD MODEL 500. MOUNT IN CEILING IN LOCATION SHOWN ON PLANS.
FURNACE AND DX COOLING COIL SCHEDULE
ELECTRIC HEATER SCHEDULEEXHAUST FAN SCHEDULE
DRYER VENT DETAIL
PLAN VIEW
CEILING MOUNTED EXHAUST FAN DETAIL
GRILLE AND REGISTER SCHEDULE
PROVIDE TRANSITION BOOT BEHIND GRILLE AS REQUIRED TO CONNECT TO BRANCH DUCT.
PROVIDE MODEL DB425 "DRYERBOX" IN WALL
WITH 4"Ø DUCT THRU ROOF. CONNECT 4"Ø
FLEXIBLE DRYER VENT TO EXHAUST DUCT
Apr 18, 2022 PHONE:
1355 EAST CENTER
POCATELLO, IDAHO 83201
ESA JOB NUMBER:
FAX:(208) 233-0529
(208) 233-0501
EMAIL:esa@engsystems.com
21147
Engineered
Systems
Associates
GD
A H
S
P-18184
TA
DIAVD
S
DTEO
L.
I
H NAF
S
R
E
P R O FN
E SGI EERT
AISON L E
NEO
I
R
E
E
N
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
4/
1
9
/
2
0
2
2
2
:
3
3
:
2
6
P
M
M3.0
MECHANICAL
SCHEDULES &
DETAILS
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
no. description date
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
ESA JOB NUMBER:21147
Engineered
Systems
Associates
4/
5
/
2
0
2
2
1
:
3
8
:
2
7
P
M
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
no.description date
Apr 18, 2022 P1.0
FOUNDATION
PLUMBING
PLAN
B
B
C
C
D
D
E
E
G
G
1 1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
8 8
F
FOUNDATION PLUMBING PLAN
SCALE: 1/8" = 1'-0"
FS-1
PLAN NOTES:
BALL TYPE ISOLATION VALVE
PIPE RISE
PIPE DROP
SYMBOL
CO
WCO
COTG
VTR
V VENT
VENT THRU ROOF
CLEANOUT
WALL CLEANOUT
CLEANOUT TO GRADE
DESCRIPTION
PLUMBING LEGEND
SOIL OR WASTE PIPING
VENT LINE PIPING
GAS PIPINGG
DOMESTIC HOT WATER PIPING
DOMESTIC COLD WATER PIPING
RDO
RDL ROOF DRAIN PIPING
ROOF OVERFLOW DRAIN PIPING
1 4" WASTE STACK UP IN WALL ABOVE TO SERVE ALL LEVELS OF
FIXTURES. SEE SHEET P1.1 FOR CONT. OF PIPING.
4" VENT STACK UP IN WALL ABOVE TO 4" VTR. SEE SHEET P1.1
FOR CONT. OF PIPING.
2" WASTE STACK UP IN WALL ABOVE. SEE SHEET P1.1 FOR CONT.
OF PIPING.
2" VENT STACK UP IN WALL ABOVE TO 2" VTR. SEE SHEET P1.1
FOR CONT. OF PIPING.
2" DOMESTIC COLD WATER UP THRU SLAB TO PRESSURE
REDUCING STATION. SEE SHEET P1.1 FOR CONT. OF PIPING.
4" FIRE LINE UP TO FIRE RISER ASSEMBLY. SEE SHEET P1.1 FOR
CONT. OF PIPING.
SEE CIVIL SITE PLAN FOR CONT. OF 4" FIRE LINE.
SEE CIVIL SITE PLAN FOR CONT. OF 2" DOMESTIC CW MAIN.
SEE CIVIL SITE PLAN FOR CONT. OF 6" SEWER MAIN.
REFER TO CIVIL DRAWINGS FOR LANDSCAPE IRRIGATION PIPING
AND METER LOCATIONS.
SEE CIVIL SITE PLAN FOR CONTINUATION OF 4" UNDERGROUND
ROOF DRAIN LINE.
4" ROOF DRAIN LINE UP THRU SLAB. SEE SHEET P1.1 FOR
CONTINUATION OF PIPING IN RISER ROOM ABOVE.
2
3
4
5
6
7
8
9
PLUMBING CONTRACTOR IS RESPONSIBLE TO
COORDINATE FINAL INVERT ELEVATIONS OF WASTE AND
ROOF DRAIN PIPING WITH CIVIL DRAWINGS AND IN-FIELD
CONDITIONS TO AVOID CONFLICTS. INVERTS SHOWN ON
THIS PLAN ARE FOR GENERAL REFERENCE ONLY.
PLUMBING CONTRACTOR IS RESPONSIBLE TO
COORDINATE THE INSTALLATION OF UNDERGROUND
PIPING WITH THE FOOTINGS. REFER TO STRUCTURAL
DRAWINGS
ALL PIPE PENETRATIONS SHALL BE PERPENDICULAR TO
THE WALLS AND FOOTINGS.
GENERAL NOTES:
1.
2.
3.
9
6" COTGINV. ELEV. MIN. -36"BELOW SLAB
8
7
6
4"
2"
5
2" V.
JS-1
2"4"
2" V. & WCO
6"6"6"6"6"6"
4"
4"
4"
2"
2"
2"
4"4"2"2"4"SH-1
2" V.
L-1
4"
12 2" V.WC-1
WB-1
KS-1
2" V.
L-1
4"
4"3"2"
12 WC-1
2" V.
T-1
WB-1
2"
3
4
2" V.FD-1
4"
4"
4"
3"
2"
2"
2"
KS-1
2"
4"
WC-1
3"
2" V.
L-1
SH-1
2" V.
2" V.
FD-1
4"
4"
2"
2"
2"
4"4"2"2"4"SH-1
2" V.
L-1
4"
1 22" V.WC-1
WB-1
KS-1
2" V.
L-1
4"
4"3"2"
1 2WC-1
2" V.
T-1
WB-1
2"
3
4
2" V.FD-1
4"
4"
4"
3"
2"
2"
2"
2"
4"
WC-1
3"
SH-1
2" V.
2" V.
FD-1
12 2
6"4"4"4"4"
4" COTGINV. ELEV. -12"BELOW SLAB
4"
4"
4"
4"
4"
4"3"
1 2
WC-1
2" V.L-1
2" V.
SH-1
FD-1
2" V.
3
4
WB-1 2"
KS-1
2" V.
L-1
4"
4"3"2"
12 WC-1
2" V.
T-1
3"
WB-1
2"
4"
4"
4"
3"
2"
2"
2"
KS-1
2"
4"
WC-1
3"
2" V.
L-1
SH-1
2" V.
2" V.
FD-1
4"
4"
2"
2"
2"
4"4"2"2"4"SH-1
2" V.
L-1
4"
1 22" V.WC-1
WB-1
KS-1
2" V.
L-1
4"
4"3"2"
1 2WC-1
2" V.
T-1
WB-1
2"
3
4
2" V.FD-1
4"
4"
4"
3"
2"
2"
2"
2"
4"
WC-1
3"
SH-1
2" V.
2" V.
FD-1
12 2
4"
4"
10
10
4" COTGINV. ELEV. -36"BELOW SLAB
11
12
12
11
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
ESA JOB NUMBER:21147
Engineered
Systems
Associates
4/
5
/
2
0
2
2
1
:
3
8
:
2
7
P
M
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
no.description date
Apr 18, 2022 P1.1
PLUMBING 1st
FLOOR PLAN
PLUMBING 1st FLOOR PLAN
SCALE: 1/8" = 1'-0"
FS-1
PLAN NOTES:
1 4" WASTE STACK UP IN WALL ABOVE TO SERVE ALL LEVELS OF
FIXTURES. SEE SHEET P1.2 FOR CONT. OF PIPING.
4" VENT STACK UP IN WALL ABOVE TO 4" VTR. SEE SHEET P1.2
FOR CONT. OF PIPING.
2" WASTE STACK UP IN WALL ABOVE. SEE SHEET P1.2 FOR CONT.
OF PIPING.
2" VENT STACK UP IN WALL ABOVE TO 2" VTR. SEE SHEET P1.2
FOR CONT. OF PIPING.
2" DOMESTIC COLD WATER PRESSURE REDUCING STATION. SEE
DETAIL ON SHEET P300.
4" FIRE RISER ASSEMBLY. SEE DETAIL ON SHEET P300.
RISE 1-1/4" DOMESTIC CW MAIN UP IN WALL TO SERVE LEVELS 2
AND 3 ABOVE. SEE SHEET P1.2 FOR CONTINUATION OF PIPING.
RISE 1" DOMESTIC CW MAIN UP IN WALL TO SERVE LEVELS 2 AND
3 ABOVE. SEE SHEET P1.2 FOR CONTINUATION OF PIPING.
1" CW LINE TO SERVE UNIT ON THIS LEVEL. SEE LARGE SCALE
PLUMBING PLANS ON SHEET P2.0 FOR CONTINUATION OF PIPING.
3/4" CW LINE TO SERVE UNIT ON THIS LEVEL. SEE LARGE SCALE
PLUMBING PLANS ON SHEET P2.0 FOR CONTINUATION OF PIPING.
2" DOMESTIC CW MAIN DOWN THRU SLAB. SEE SHEET P1.0 FOR
CONTINUATION OF PIPING.
GAS METER TREE WITH (12) GAS METERS SIZED FOR 65,000 BTU
EACH AT OZ. DELIVERY PRESSURE.
DROP 3/4" (OZ.) GAS LINE DOWN THRU CEILING OF MECH. CLOSET
AND CONNECT TO FURNACE COMPLETE WITH SHUT-OFF VALVE,
FLEXIBLE CONNECTION AND DIRT LEG. SEE DETAIL ON SHEET
P3.0.
RUN (24) 3/4" OZ. GAS LINES FROM METER TREES UNDERGROUND
TO EXTERIOR WALL OF BUILDING.
RISE (24) 3/4" OZ. GAS LINES UP THRU CONCRETE SLAB
SIDEWALK ON EXTERIOR SIDE OF BUILDING AND PENETRATE
EXTERIOR WALL WITH PIPING TO STUD SPACE / CHASE. SEE
ARCH. PLANS FOR PIPE COVERING ON EXTERIOR OF BUILDING
AT SIDEWALK.
RISE (16) 3/4" OZ. GAS LINES UP IN CHASE TO SERVE LEVELS 2
AND 3 ABOVE. SEE SHEET P1.2 FOR CONTINUATION OF PIPING.
RUN (6) 3/4" GAS LINES IN CEILING SPACE OF MAIN LEVEL HALL
WAY TO SERVE MAIN LEVEL UNITS.
RUN (4) 3/4" GAS LINES IN CEILING SPACE OF MAIN LEVEL HALL
WAY TO SERVE MAIN LEVEL UNITS.
RUN (2) 3/4" GAS LINES IN CEILING SPACE OF MAIN LEVEL HALL
WAY TO SERVE MAIN LEVEL UNITS.
2
3
4
5
6
2" V. UP JS-1
12 12
3
4
1
2
3
4
12
B
B
C
C
D
D
E
E
G
G
1 1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
8 8
FAV
PRV
WH-2
(ABOVE)
L-1 WC-1
WB-1
SH-1
WH-1
FD-1
2
F
5
L-1 WC-1
T-1
DW-1
KS-1
WB-1
12
WC-1
L-1
SH-1
WH-1 FD-1
1
F
KS-1
DW-1
1 212
L-1WC-1
WB-1
SH-1
WH-1
FD-1
2
F
L-1WC-1
T-1
DW-1
KS-1
WB-1
1 2
WC-1
L-1
SH-1
WH-1FD-1
1
F
KS-1
DW-1
WB-1
12
WC-1
L-1
SH-1
WH-1 FD-1
1
F
KS-1
DW-1
1 212
L-1WC-1
WB-1
SH-1
WH-1
FD-1
2
F
L-1WC-1
T-1
DW-1
KS-1
WB-1
1 2
WC-1
L-1
SH-1
WH-1FD-1
1
F
KS-1
DW-1KS-1
DW-1
WC-1L-1
T-1
WH-1 FD-1 3
F
SH-1
L-1WC-1
WB-1
1-1/4"
1-1/4"
2"
6
7
2"
ENTIRE BUILDING TO BE FIRE SPRINKLED
AS PER NFPA-13 CODE REQUIREMENTS.
NOTE:SEE LARGE SCALE TYP. UNIT PLUMBING
PLANS ON SHEETS P2.0 FOR PIPING
SERVING INDIVIDUAL UNIT TYPES.
NOTE:
1-1/4"
1-1/4"2"
8
7
9
9
10
8
1-1/4"
1-1/4"
1-1/4"
1-1/4"
10
8 1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
9
7
FAV
PRV
ROOM PLUMBING PLAN
SCALE: 1/4" = 1'-0"
LARGE SCALE FIRE RISER
HB-1
WH-2
(ABOVE)
5
FS-16
2"
2"
2"
2"
3/4"
3/4"
JS-1
2" V. & WCO
11
12
11
7
8
1-1/4"
1-1/4"
1-1/4"
1-1/4"
8 1-1/4"
1-1/4"
7
2"2"1-1/2"
9
9
1-1/4"
1-1/4"
3
4
12
G
G
G
G
3/4"
3/4"
13
13
G
G
G
3/4"13
3
4
3/4"
3/4"
3/4"
13
G
3/4"
3/4"
13
10
G
G
3/4"
3/4"
13
G
G
3/4"
3/4"
13
10
G
G
G
13
G
12
G
G
G
3/4"13
3/4"
G G GGGG G GGG
3/4"
3/4"
14
15
15
14
14
(12) 3/4" GAS LINES
UNDERGROUND
(12) 3/4" GAS LINES
UNDERGROUND
16
16
(8) 3/4" GAS LINES
IN CLG. SPACE
17
1718
18
19
19
UNIT 2
102
TYPE A
UNIT 1
106
TYPE B
UNIT 1
104
TYPE AUNIT 3
108
TYPE A
UNIT 2
101
TYPE B
UNIT 1
105
TYPE B
UNIT 1
103
TYPE B
UNIT 2
107
TYPE B
JANITOR
STAIR B STAIR A
JANITOR
DS-1(+18" A.F.F)
4" RDL UP IN CHASE
4" RDO UP IN CHASE
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
ESA JOB NUMBER:21147
Engineered
Systems
Associates
4/
5
/
2
0
2
2
1
:
3
8
:
2
7
P
M
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
no.description date
Apr 18, 2022 P1.2
PLUMBING 2nd
FLOOR PLAN
PLUMBING 2nd FLOOR PLAN
SCALE: 1/8" = 1'-0"
PLAN NOTES:
1 4" WASTE STACK UP IN WALL ABOVE TO SERVE ALL LEVELS OF
FIXTURES.
4" VENT STACK UP IN WALL ABOVE TO 4" VTR. SEE SHEET P1.3
FOR CONT. OF PIPING.
2" WASTE STACK UP IN WALL ABOVE.
2" VENT STACK UP IN WALL ABOVE TO 2" VTR. SEE SHEET P1.3
FOR CONT. OF PIPING.
1-1/4" DOMESTIC CW MAIN UP IN WALL FROM BELOW. TEE 1" CW
TO SERVE UNIT ON THIS LEVEL AND CONTINUE UP WITH 1" CW
MAIN TO SERVE UNIT ON LEVEL 3 ABOVE. SEE SHEET P1.3 FOR
CONTINUATION OF PIPING.
1" DOMESTIC CW MAIN UP IN WALL FROM BELOW. TEE 3/4" CW
TO SERVE UNIT ON THIS LEVEL AND CONTINUE UP WITH 3/4" CW
MAIN TO SERVE UNIT ON LEVEL 3 ABOVE. SEE SHEET P1.3 FOR
CONTINUATION OF PIPING.
1" CW LINE TO SERVE UNIT ON THIS LEVEL. SEE LARGE SCALE
PLUMBING PLANS ON SHEET P2.0 FOR CONTINUATION OF PIPING.
3/4" CW LINE TO SERVE UNIT ON THIS LEVEL. SEE LARGE SCALE
PLUMBING PLANS ON SHEET P2.0 FOR CONTINUATION OF PIPING.
RISE (8) 3/4" OZ. GAS LINES UP IN CHASE TO SERVE LEVEL 3
ABOVE. SEE SHEET P1.3 FOR CONTINUATION OF PIPING.
RUN (6) 3/4" GAS LINES IN CEILING SPACE OF HALL WAY TO
SERVE 2ND LEVEL UNITS.
RUN (4) 3/4" GAS LINES IN CEILING SPACE OF HALL WAY TO
SERVE 2ND LEVEL UNITS.
RUN (2) 3/4" GAS LINES IN CEILING SPACE OF HALL WAY TO
SERVE 2ND LEVEL UNITS.
DROP 3/4" (OZ.) GAS LINE DOWN THRU CEILING OF MECH. CLOSET
AND CONNECT TO FURNACE COMPLETE WITH SHUT-OFF VALVE,
FLEXIBLE CONNECTION AND DIRT LEG. SEE DETAIL ON SHEET
P3.0.
2
3
4
2" V. UP
12 12
3
4
3
4
12
B
B
C
C
D
D
E
E
G
G
1 1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
8 8
L-1 WC-1
WB-1
SH-1
WH-1
FD-1
2
F
L-1 WC-1
T-1
DW-1
KS-1
WB-1
12
WC-1
L-1
SH-1
WH-1 FD-1
1
F
KS-1
DW-1
1 212
L-1WC-1
WB-1
SH-1
WH-1
FD-1
2
F
L-1WC-1
T-1
DW-1
KS-1
WB-1
1 2
WC-1
L-1
SH-1
WH-1FD-1
1
F
KS-1
DW-1
WB-1
12
WC-1
L-1
SH-1
WH-1 FD-1
1
F
KS-1
DW-1
1 212
L-1WC-1
WB-1
SH-1
WH-1
FD-1
2
F
L-1WC-1
T-1
DW-1
KS-1
WB-1
1 2
WC-1
L-1
SH-1
WH-1FD-1
1
F
KS-1
DW-1KS-1
DW-1
WC-1L-1
T-1
WH-1 FD-1 3
F
SH-1
L-1WC-1
WB-1
5
3
4
3
4
6
7
8
5
7
5
7
5
7
6 6
8
6
8
6
5
7
1
2
G
G
G
GG
G
3/4"
3/4"
13
G
G
G
G
3/4"13
3/4"
3/4"
3/4"
13
G
G
3/4"
3/4"
13
G
G
3/4"
3/4"
13
G
G
3/4"
3/4"
13
G
G
13
G
G
G
G
G
3/4"13
3/4"
G G GGGG G GGG
3/4"
3/4"
(8) 3/4" GAS LINES
IN CLG. SPACE
101112
8
9
10
11
12
9
13
8
STAIR B STAIR A
UNIT 2
202UNIT 1
206 UNIT 1
204UNIT 3
208
UNIT 2
201
UNIT 1
205
UNIT1
203
UNIT 2
207
4" RDL UP IN CHASE
4" RDO UP IN CHASE
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
ESA JOB NUMBER:21147
Engineered
Systems
Associates
4/
5
/
2
0
2
2
1
:
3
8
:
2
7
P
M
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
no.description date
Apr 18, 2022 P1.3
PLUMBING 3rd
FLOOR PLAN
PLUMBING 3rd FLOOR PLAN
SCALE: 1/8" = 1'-0"
PLAN NOTES:
1 4" VENT STACK UP IN WALL TO 4" VTR.
2" VENT STACK UP IN WALL TO 2" VTR.
1" CW LINE TO SERVE UNIT ON THIS LEVEL. SEE LARGE SCALE
PLUMBING PLANS ON SHEET P2.0 FOR CONTINUATION OF PIPING.
3/4" CW LINE TO SERVE UNIT ON THIS LEVEL. SEE LARGE SCALE
PLUMBING PLANS ON SHEET P2.0 FOR CONTINUATION OF PIPING.
DROP (8) 3/4" OZ. GAS LINES DOWN IN CHASE. SEE SHEET P1.2
FOR CONTINUATION OF PIPING.
RUN (6) 3/4" GAS LINES IN CEILING SPACE OF HALL WAY TO
SERVE 3RD LEVEL UNITS.
RUN (4) 3/4" GAS LINES IN CEILING SPACE OF HALL WAY TO
SERVE 3RD LEVEL UNITS.
RUN (2) 3/4" GAS LINES IN CEILING SPACE OF HALL WAY TO
SERVE 3RD LEVEL UNITS.
DROP 3/4" (OZ.) GAS LINE DOWN THRU CEILING OF MECH. CLOSET
AND CONNECT TO FURNACE COMPLETE WITH SHUT-OFF VALVE,
FLEXIBLE CONNECTION AND DIRT LEG. SEE DETAIL ON SHEET
P3.0.
2
3
2" VTR
1 1
2
2
1
B
B
C
C
D
D
E
E
G
G
1 1
5 5
6 6
10 10
3 3
F
F
7 7
A
A
2 2
9 9
4 4
8 8
L-1 WC-1
WB-1
SH-1
WH-1
FD-1
2
F
L-1 WC-1
T-1
DW-1
KS-1
WB-1
1
WC-1
L-1
SH-1
WH-1 FD-1
1
F
KS-1
DW-1
11
2
L-1WC-1
WB-1
SH-1
WH-1
FD-1
2
F
L-1WC-1
T-1
DW-1
KS-1
WB-1
1
WC-1
L-1
SH-1
WH-1FD-1
1
F
KS-1
DW-1
WB-1
1
WC-1
L-1
SH-1
WH-1 FD-1
1
F
KS-1
DW-1
11
2
L-1WC-1
WB-1
SH-1
WH-1
FD-1
2
F
L-1WC-1
T-1
DW-1
KS-1
WB-1
1
WC-1
L-1
SH-1
WH-1FD-1
1
F
KS-1
DW-1KS-1
DW-1
WC-1L-1
T-1
WH-1 FD-1 3
F
SH-1
L-1WC-1
WB-1
4
3 3
3
33
1
G
G
G
GG
G
3/4"
3/4"
9
G
G
G
G
3/4"9
3/4"
3/4"
3/4"
9
G
G
3/4"
3/4"
9
G
G
3/4"
3/4"
9
G
G
3/4"
3/4"
9
G
G
9
G
G
G
G
G
3/4"9
3/4"
G G GGGG G G G
3/4"
3/4"
(8) 3/4" GAS LINES
IN CLG. SPACE
678
3
3 3
5
6
7
8
9
5
UNIT 2
302UNIT 1
306
UNIT 1
304
UNIT 3
308
UNIT 2
301UNIT 1
305
UNIT 1
303
UNIT 2
307
STAIR B STAIR A
RDL RDL RDL RDL RDLRDORDORDORDORDORDORDORDO
4" RDL DN. IN CHASE
4" RDO DN. IN CHASE
4"3"3"3"
RD-1
(ABOVE)
OD-1
(ABOVE)
2,343 SQ. FT.
ROOF AREA
RD-1
(ABOVE)
2,725 SQ. FT.
ROOF AREA
OD-1
(ABOVE)
RD-1
(ABOVE)
2,725 SQ. FT.
ROOF AREA
OD-1
(ABOVE)
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
ESA JOB NUMBER:21147
Engineered
Systems
Associates
4/
5
/
2
0
2
2
1
:
3
8
:
2
7
P
M
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
no.description date
Apr 18, 2022 P2.0
LARGE SCALE
TYP. UNIT
PLUMBING PLANS
1 BED LARGE SCALE PLUMBING PLAN
SCALE: 1/4" = 1'-0"
2 BED LARGE SCALE PLUMBING PLAN
SCALE: 1/4" = 1'-0"
3 BED LARGE SCALE PLUMBING PLAN
SCALE: 1/4" = 1'-0"
PLAN NOTES:
1 4" WASTE STACK SERVING ALL LEVELS.
4" VENT STACK UP SERVING ALL LEVELS TO 4" VENT THRU ROOF.
RUN 3/4" CONDENSATE DRAIN LINE FROM FURNACE TO FLOOR
DRAIN LOCATED IN MECH. ROOM. TERMINATE WITH
DOWNTURNED 90° ELBOW AND AIR GAP.
INSTALL BALL TYPE SHUT-OFF VALVE ON 3/4" CW MAIN SERVING
UNIT, BELOW CEILING OF MECH. CLOSET.
INSTALL BALL TYPE SHUT-OFF VALVE ON 1" CW MAIN SERVING
UNIT, BELOW CEILING OF MECH. CLOSET.
2" WASTE STACK SERVING ALL LEVELS.
2" VENT STACK UP SERVING ALL LEVELS TO 4" VENT THRU ROOF.
DROP 1/2" CW & HW PIPING DOWN IN WALL AND RUN UNDER
COUNTERTOP TO SERVE KITCHEN SINK AND DISHWASHER.
DROP 1/2" CW & HW PIPING DOWN IN WALL AND RUN UNDER
COUNTERTOP TO BATHROOM LAVATORY AND 1/2" CW TO TOILET.
DOMESTIC CW MAIN LINE IN WALL. SEE PLUMBING FLOOR PLANS
ON SHEET P1.1, P1.2 AND P1.3 FOR PIPE SIZES SERVING EACH
LEVEL.
2" ISLAND SINK VENT. SEE DETAIL ON SHEET P3.0.
2
3
4
5
6
7
8
WC-1
1
F
WH-1
FD-1
SH-1
WB-1
L-1
DW-1
KS-1
2
F
3
F
SH-1
WC-1L-1
WB-1
KS-1
DW-1
T-1WC-1L-1
WH-1 FD-1
WC-1
WC
-
1
DW-1
KS-1
L-1 T-1
WB-1
SH-1
L-1
WH-1 FD-1
12
2 12
12 2"
V
.
2"
V
.
1
2
3
3
3
4
5
5
6
7
7
6
8
8
9
9
2" V.
10
10
10
10
2" V.
2" V.
11
11
11
2"
V
.
2"
V
.
2"
V
.
2" V.
2"
2" V.
2"
1"
3/4"
3/4"3/4"1/2"
1/2"2"2"
2"3"
2"
2"
1/2"
3/4"1/2"
2"
1/2"
2"2"2"
1
3"
2"2"
3/4"
2"
1/
2
"
1/
2
"
1/
2
"
1/
2
"
3/4"
1"
3/4"
3/4"
3/
4
"
3/4"
3/4"
3/4"
1/2"
1/2"
2"
2"
2"
V
.
2" V.
2"
2"
3"
2"
1/2"
2"
2"
1/2"1/2"
3"
2" V.
1/2"
3/4"3/4"1/2"1/2"
2"2"
3"2"
2"
2"
1/2"
1/2"
2"
2"
3/4"
3/4"3/4"3/4"
2"
2"
3/4"1"
2"
2"3"
1/2" BELOW COUNTER
3"3"
2"
2"
1/2"
3/4"
M. BEDROOM
M. BATHROOM
LIVING
KITCHEN
KITCHEN
KITCHENLIVING
LIVING
M. BEDROOM
BEDROOM 1
BATH 1
M. BATHROOM
M. BATHROOM
M. BEDROOM
BEDROOM 1
BEDROOM 2
BATHROOM 1
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
ESA JOB NUMBER:21147
Engineered
Systems
Associates
4/
5
/
2
0
2
2
1
:
3
8
:
2
7
P
M
2115
4/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
no.description date
Apr 18, 2022 P3.0
PLUMBING
DETAILS &
SCHEDULESWASHER BOX PIPING DETAIL
NO SCALE
42
"
T
O
2" WASTE LINE
2" VENT LINE UP
1/2" HOT WATER LINE
1/2" COLD WATER LINE
STUD WALL
AT 16" O.C.
2x4 WOOD HEADER
ABOVE UTILITY BOX
FINISHED FLOOR
DROP 2" WASTE LINE DOWN
BELOW FLOOR
SHUT-OFF VALVES
2" P-TRAP
FL
O
O
R
NO SCALE
WATER HEATER PIPING DIAGRAM
UNION (TYP)
BALL VALVE (TYP)
WATER HEATER
HEAT TRAP FITTING
COLD WATER LINE
HOT WATER LINE
PIPE FULL SIZE TO
FLOOR DRAIN
ASME T&P RELIEF
VALVE
SEISMIC BRACING
STRAPS ANCHORED TO
WALL
2" DEEP DRAIN PAN
UNDER HEATER
DRAIN VALVE WITH THREADED
HOSE CONNECT.
COLD WATER
INLET
TAKEN NOT TO DEFORM OR OTHERWISE DAMAGE PIPING OR INSULATION.
TAMPED, RODDED OR LIGHTLY COMPACTED DURING INSTALLATION. CARE SHOULD BE
SAND FILL AROUND PIPING SHALL BE A MINIMUM OF 4" THICK. MATERIAL SHALL BE HAND
MINIMUM PIPE SIZE UNDERFLOOR SHALL BE 3/4"
PIPE INSULATION. TAPE INSULATION AT ALL SEAMS.
WATER PIPE INSULATION ON UNDERFLOOR PIPING SHALL BE ARMAFLEX 3/4" THICK RUBBER
ALL WATER PIPING INSTALLED UNDERFLOOR SHALL BE TYPE "K" COPPER OR PEX
UNDER SLAB PIPE INSTALLATION DETAIL
3
NO SCALE
4 -
SECTION 'A'
NOTES:
2
-
-
1 -
COMPACTED EARTH
CONCRETE
4"
4"
1" MIN.
INSULATION SAND
WATER PIPING
A
NO SCALE
VERTICAL FIRE RISER DETAIL
NOTE:
WE
T
R
I
S
E
R
4" WATER SUPPLY FROM CITY WATER MAIN. USE CLASS 53 DUCTILE IRON
WHEN CROSSING UNDER BLDG FOUNDATION.
USE FLEXIBLE GROOVED PIPE COUPLING ONLY IF SEISMIC BRACING IS
REQUIRED. SEE NOTE #12.
GROOVED BUTTERFLY VALVE WITH INTEGRAL SUPERVISORY SWITCH.
DOUBLE CHECK BACKFLOW PREVENTER WITH RELATED TRIM AND GAUGES.
3-1/2" DIAMETER WATER GAUGE WITH 1 4" TEST AND ISOLATION VALVE.
VANE TYPE WATER FLOW SWITCH.
SUPPLY TO WET PIPE FIRE SPRINKLER SYSTEM.
SWING CHECK VALVE.
RISER MANIFOLD - INCLUDES PRESURE GAUGE, FLOW SWITCH, PRESSURE
RELIEF VALVE, AND TEST AND MAIN DRAIN DEVICE.
INSPECTOR'S TEST & MAIN DRAIN DEVICE - PIPE TO OUTSIDE.
PRESSURE RELIEF VALVE SHALL BE REQUIRED SET AT 175 PSI.- PIPED TO
DISCHARGE OUTSIDE.
SEISMIC BRACING REQUIRED IN SEISMIC DESIGN CATEGORY C, D, E, F.
1/2" AUTOMATIC BALL DRIP VALVE.
PIPE TO DRAIN OUTSIDE.
WEATHERPROOF ELECTRIC BELL OR HORN AND STROBE (OUTSIDE).
OUT TO FIRE DEPARTMENT CONNECTION WITH GALVANIZED SCH 40 PIPING-
PROVIDE BALL DRIP WHEN TRAPPING PIPE. SIZE CONNECTION AS REQUIRED.
NOTE: PIPE FDC TO REMOTE LOCATION WHEN REQUIRED BY FIRE MARSHAL.
GALVANIZED FLANGE AND SPOOL PIECE
CLASS 53 D.I. FLANGED SPIGOT
3/4" A.T.R.
3/4" BENT EYE BOLT
MECHANICAL JOINT 90° ELL
CONCRETE THRUST BLOCK WITH 5 SQ. FEET BEARING AREA
UNDISTURBED EARTH
LOW TEMPERATURE SENSOR - MOUNTED ON WALL - THIS SWITCH IS
PROVIDED UNDER DIVISION 28 OF THE SPECIFICATIONS.
SPARE HEAD CABINET WITH SPARE SPRINKLER HEADS AND WRENCHES.
LAMINATED SYSTEM MAP WITH SYSTEM START-UP AND SHUT-DOWN
INSTRUCTIONS.
PROVIDE SLEEVES WHERE PIPING PENETRATES BUILDING AT FLOOR AND
WALLS. SEAL AROUND PENETRATION WITH FLEXIBLE MASTIC AT FLOOR.
PROVIDE 2" ANNULAR SPACE AROUND AND RESTRAIN FLANGE SPIGOT.
5'
-
6
"
M
I
N
.
0'
-
6
"
1'
-
0
"
FLOOR SLEEVE
FS
TS
LT
IT
26
25
24
23
22
21
20
21
22
23
1
20
19
19
18
17
16
15
14
18
17
2
3
4
5
13
14
16
13
12
11
10
9
8
7
6
25
5
9
6
3
5
8
24
10
11
5
4
3
2
1
72
12
15
26
WH-1
NO SCALE
HEATER MOUNTING DETAIL
CEILING
DRAIN PAN. PIPE TO FLOOR SINK
WATER HEATER
STEEL SAFETY STRAP
WALL
1-1/2" x 1/4" ANGLE IRON
SUPPORT. PRIMED AND
PAINTED TO MATCH WALL
AND BOLTED TO BUILDING.
WH-2
JANITOR CLOSET WATER
TRAPSYM.DESCRIPTION
PLUMBING FIXTURE SCHEDULE
PIPE SIZEVENTWASTE C.W.H.W.REMARKS
WATER CLOSETWC-1 2"INT.3"1/2"-ELONGATED BOWL FLUSH TANK WITH SEAT AND LID
WASHER BOXWB-1 2"2" 2"1/2"1/2"POLY WASHER BOX WITH 1/2" HW AND CW STOP VALVES
2" STANDPIPE WITH P-TRAP
LOWBOY ELECTRIC
WH-1 -- -3/4"3/4"40 GALLON ELEC. WATER HEATER WITH T&P VALVE & DRAIN PAN. 240/60/1
POWER. 4500 WATT UPPER & LOWER NON-SIMULTANEOUS ELEMENTS.ELEC. WATER HEATER
WH-2 -- -3/4"3/4"20 GALLON ELEC. WATER HEATER WITH T&P VALVE & DRAIN PAN. 240/60/1
POWER. 4500 WATT UPPER & LOWER NON-SIMULTANEOUS ELEMENTS.WATER HEATER
1-1/2"LAVATORYL-1 1-1/2"1-1/2"1/2" 1/2" COUNTERTOP MOUNT
ISLAND SINK VENTING DETAIL
WCO
NO SCALE
1-1/2"2"
2"
TYPICAL SINK 2"
2" VENT PIPE
2"
FOOT VENT2"
NEAREST
PARTITION
4"FLOOR SINKFS-1 2"4"--- ---
ZURN Z-1900-KC WITH WHITE ENAMEL FINISH, DOME STRAINER AND 4"
DEEP SEAL P-TRAP. PROVIDE 3/4 GRATE OVER SINK.
2"FLOOR DRAINFD-1 2"2"--- ---
ZURN Z-415B WITH 5"Ø NICKEL-BRONZE STRAINER AND 2" DEEP SEAL
P-TRAP
2"JANITOR SINKJS-1 2"2"1/2" 1/2"
KOHLER K-6710 "WHITBY" W/ K-8940 WIRE RIM GUARD, K-8928 FAUCET
ASSEMBLY & K-9142 STRAINER & DEEP SEAL P-TRAP. HOSE & HOSE CLAMP
2"KITCHEN SINKKS-1 2"2"1/2" 1/2" COUNTERTOP MOUNT WITH DISPOSER (120/60/1 POWER REQUIRED)
-DISHWASHERDW-1 -3/4"- 1/2"
UNDER COUNTER - CONNECT WATER & WASTE TO ADJACENT SINK / GARBAGE DISPOSER
1-1/2"TUB / SHOWERT-1 1-1/2"1-1/2"1/2" 1/2"
RIGHT OR LEFT HAND AS PER FLOOR PLAN
1-1/2"SHOWERSH-1 1-1/2"1-1/2"1/2" 1/2"
RIGHT OR LEFT HAND AS PER FLOOR PLAN
6"
V
E
R
T
I
C
A
L
GAS LINE CONNECTION DETAIL
NO SCALE
DROP FROM
MAIN. SEE
PLAN FOR
SIZE
MANUAL MAIN
SHUT-OFF
VALVEGROUND
JOINT UNION
EQUIPMENT
CASING
FLEXIBLE GAS
CONNECTOR. 18" MAX.
FLEX PIPE SIZE TO
MATCH DROP
DRIP LEG
SAME SIZE
AS DROP
---EXTERIOR HOSE BIBBHB-1 ------3/4" ---
FREEZEPROOF EXTERIOR HOSE BIBB WITH
REMOVABLE KEY. LENGTH TO SUIT WALL THICKENESS
JAY R SMITH MODEL 1770 SIZE 4" WITH ROUGH BRONZE
FINISH AND 4" DRAIN LINE CONNECTION.ROOF OVERLOW DRAINDS-1 -- 4" --DOWNSPOUT
ROOF DRAINRD-1 -- 3" --JAY R SMITH MODEL 1010 SIZE 3" WITH UNDERDECK
CLAMP AND FLASHING.
ROOF OVERLOW DRAINOD-1 -- 3" --JAY R SMITH MODEL 1080 SIZE 3" WITH 2" HIGH WATER
DAM, UNDERDECK CLAMP AND FLASHING.
NO SCALE
WATER PRESSURE REDUCING STATION DETAIL
(TYPICAL)
BALL VALVE
2" TO FIXTURES
DIRT LEG
UNION
TYPICAL
3/4" DRAIN VALVE
5'-0"
CONTRACTOR
BY PLUMBING
CONTRACTOR
BY SITE UTILITIES
CAP
GRADE
EXT WALL
36"
COMBINATION PRESSURE
REDUCING VALVE AND STRAINER.
SET DISCHARGE AT 50 PSIG TRERICE 3-1/2"
NO. 800, RANGE
0-TO-100 PSI RISE TO
CEILING
SPACE
1'-0" MINIMUM
CLEARANCE
REDUCED PRESSURE
BACKFLOW PREVENTER
DRAIN
VALVE
1-1/4" CW LINE OUT FOR
SPRINKLER SYSTEM
2" WATER SUPPLY
TO BUILDING
WATER
METER
REMOTE READOUT
DEVICE FOR BLDG. METER
DOUBLE CHECK VALVE
BACKFLOW PREVENTER WITH
BALL VALVES AND STRAINER
REMOTE READOUT DEVICE
FOR IRRIGATION METER
REFER TO CIVIL SITE PLANS FOR
NUMBER OF BUILDINGS REQUIRING
LAWN IRRIGATION.
1
NOTES:
1
1
1
1
ELECTRICAL SPECIFICATIONS
1. INTENT:
Provide and install complete and operable electrical systems
including but not not limited to; lighting, power, receptacles,
data, fire alarm ande etc.
Provide all required connections to all Mechanical and
Plumbing equipment, as indicated and required, including all
conduits, wiring and controls. Coordinate with mechanical
contractor and drawings.
2. COMPLIANCE WITH CODES:
All work and material shall comply with all applicable codes,
safety orders, laws, ordinances and regulations of governing
authorities and other agencies having jurisdiction including
regulations of the State and Local Fire Marshall, unless
detailed as specified to a more restrictive standard or higher
requirement.
3. INTERPRETATION OF DRAWINGS:
The electrical drawings are essentially diagrammatic in that
all provisions necessary to conform to structural,
architectural, mechanical and plumbing systems can not be
shown. All installations shall be adjusted as necessary to
conform and to avoid obstructions, without additional cost to
the owner.
All work, material and equipment called for by notes,
schedules or otherwise indicated on the drawings shall be
furnished and isntalled as though fully set forth in these
specifications.
4. VISITING THE SITE:
Contractor shall visit the site and become acquainted with
conditions to be encounterd. Extra funds will not be allowed
due to failuer to examine the site and to included existing
conditions in bid price.
5. COORDINATION WITH UTILITIES:
These plans have been prepared without utility company
comments. The contractor shall verify exact requirements for
the electrical, telephone and communication services with the
utility company representatives and provide all work and pay
all costs for a complete and operating systems, as directed by
the governing utilities.
6. MATERIALS AND WORKMANSHIP:
All workmanship shall be performed by skilled electricians
using the best standard practives of the trade. All materials
shall, unless otherwise noted, be new and in perfect
condition and working order. All material for similar uses shall
be of the same type, material and manufacturer for ease of
future maintaenance.
All equipment shall be readily accessible for maintenance and
repairs. All materials, fixtures and equipment shall be
covered or sealed upon installation so as to provide for safety
and to insure that operation and appearance will be
maintained after subsequent construction operations.
7. EXECUTION:
Raceway installation: Seperate underground conduits in a
common trench 4" minimum horizontally, 12" minimum from
other utility lines. Minimum conduit depth shall be 18".
Coordinate conduit installation with pipes, steel, footings and
ducts installed by other trades. Install conduit runs exposed to
view parallel or at right angles to structural members, walls or
building lines. Support conduit with one-hole malleable factory
made pipe straps, fastended with screws.
8. OPERATING AND ADJUSTING:
The owner reserves the right to operate any systems of
equipment prior to final comletion and acceptance of the work.
Such perliminary operation shall not be construed as an
acceptance of any work.
Each piece of equipment and all of the systems shall be
adjusted to insure proper functioning and shall be left in first
class operating condition.
9. CUTTING AND PATCHING:
Do all drilling and cutting as necessary for installation of
equipment or conduit. Cutting or drilling of structure is only
permitted with prior approval of the owner and structural
engineer.
Where cutting and patching of work is necessary, use the
same materials, workmanship and finish to neatly match all
surrounding work.
10. CONDUIT:
All conduit material and installation methods shall be as
allowed by the NEC, local AHJ and as directed by the
owner.
11. CONDUCTORS:
Type THWN or THHN copper wire insulated for 600V.
Smallest wire shall be #14 AWG unless noted otherwise.
All wiring shall be Copper unless indicated otherwise.
Type MC cable shall be permitted, provided it is installed in
concealed areas and installation complies with the Local AHJ
and NEC requirements.
Type NM cable is only permitted in locations allowed by the
Local AHJ and NEC.
Use "Ideal Yellow" pulling compound for all wire pulls.
Use Scotchlock connectors for all splices in #12 wire and
tape bolted pressure connectors for larger wire.
12. GROUNDING:
All conduit, branch circuits, feeders and etc. shall be
provided with a grounding conductor. All grounding
conductors shall be insulated and green in color, size as
shown.
13. WIRING DEVICES:
Devices shall be Standard type, Specification grade, color
as selected by owner. Decora style devices are prohibited.
Utilize GFCI and Tamper-proof devices in all locations as
defined by the NEC.
Wiring devices shall be as installed as allowed by the
NEC, local AHJ.
14. DEVICE PLATES:
Devices plate type and color shall be as directed by owner
and as required by the NEC.
15. LIGHTING FIXTURES:
As selected by owner and/or indicated in schedules. All light
fixtures shall be installed and connected by the Electrical
Contractor.
16. SERVICE EQUIPMENT & PANELBOARDS:
Service Equipment: Shall be rated as such and shall comply
with local utility co. requirments. .
Panelbards: Shall be provided with typed writtend directories
indicating loads being served.
Maintain all required clearances around equipment as
required by the NEC.
All equpment dimensions to be field verified.
17. CLEAN-UP:
Upon completion of the work, prior to final inspection,
thoroughly clean all exposed fixtures, trim and equipment
and leave the entire installation in a neat, clean and usable
condition. Remove all cement, paint, grease, oil and other
foreign substances.
18. TEST:
Test all conductors for shorts, opens, grounds or other
defects. Correct any defective work and re-test.
Demonstrate continuous satisfactory operation of all
electrical systems and equipment.
Provide training to the owner on electrical systems as
needed for owner operation and maintenance of building.
19. GUARANTEE:
Prior to final acceptacne of the project, deliver to the owner
a written one year guarantee on all workmanship, materials
and equipment and agree to repair or replace all such
defective items promptly that may occure during the
warranty period; including repair or replacement of the
premises that may be damaged due to faulty work and
materials furnished under contract.
CIRCUITING & GENERAL SYMBOL SCHEDULE
NOTE: ALL SYMBOLS MAY NOT BE USED
SYMBOL DESCRIPTION
KEYED NOTE REFERENCE1
BRANCH CIRCUIT HOME-RUN TO PANEL INDICATED
A-1,3,5
3/4"C.-6#12,1#12G
QTY & SIZE OF EQUIPMENT GROUND CONDUCTOR
QTY & SIZE OF NEUTRAL AND PHASE CONDUCTOR(S)
SIZE OF CONDUIT
A-1,3,5
3/4"C.-6#12,1#12G
PANEL AND CIRCUIT DESIGNATIONS
EQUIPMENT GROUNDING CONDUCTOR
TICK MARKS
NEUTRAL CONDUCTOR(S)
PHASE AND/OR SWITCH-LEG CONDUCTOR(S)
BRANCH CIRCUIT/FEEDER CONCEALED IN CEILING OR WALL
BRANCH CIRCUIT/FEEDER CONCEALED UNDERGROUND OR FLOOR
NEW EQUIPMENT, DEVICES, ETC.
EXISTING EQUIPMENT, DEVICES, ETC.
DEMOLITION EQUIPMENT, DEVICES, ETC.
DETAIL # / SHEET REFERENCE1 / ES101
*25,000A CALCULATED AVAILABLE FAULT CURRENT AT EQUIPMENT(SEE POWER RISER)
FIRE ALARM SYMBOL SCHEDULE
NOTE: ALL SYMBOLS MAY NOT BE USED
SYMBOL DESCRIPTION
DETECTOR SUBSCRIPTS
P PHOTOELECTRIC SMOKE DETECTOR D DUCT SMOKE DETECTOR
ID IN-DUCT SMOKE DETECTOR H HEAT DETECTOR
M MULTI-STATION SMOKE/CO DETECTOR, MONITORED BY FACP
(120V W/BATTERY BACKUP)
FIRE ALARM CONTROL PANEL (WALL MOUNTED, TOP AT 6'-0' AFF)
F
FACP
NOTIFICATION DEVICE EXTENDER PANEL. PROVIDE QTY AS REQUIRED BASED ON DEVICE
VOLTAGE DROP CALC'S PER NFPA 72 REQUIREMENTS. (WALL MOUNTED, TOP AT 5'-0' AFF)
REMOTE ANNUCIATOR PANEL (FLUSH MOUNTED IN WALL AT 5'-0' AFF)
NAC
RA
MANUAL PULL STATION (MOUNTING HEIGHT PER ADA & NFPA 72)
MAGNETIC DOOR HOLD OPEN
ADDRESSABLE CONTROL/RELAY MODULE
MM
CM
ADDRESSABLE MONITORING MODULE
FIRE ALARM FLOW SWITCH
FIRE ALARM TAMPER SWITCH
FS
TS
WALL MOUNTED FIRE ALARM HORN ONLY
WALL MOUNTED FIRE ALARM STROBE ONLY
(CANDELA RATING AS INDICATED)
#
ADDRESSABLE DETECTOR WITH BASE
##
##CEILING MOUNTED FIRE ALARM STROBE ONLY
(CANDELA RATING AS INDICATED)
##
##
WALL MOUNTED FIRE ALARM HORN STROBE
(CANDELA RATING AS INDICATED)
CEILING MOUNTED FIRE ALARM HORN STROBE
(CANDELA RATING AS INDICATED)
EXTERIOR 120V FIRE BELL, INSTALL NEXT TO FDC.
FIRE/SMOKE DAMPER; COORDINATE LOCATIONS WITH MECH. DRAWINGSSD
A. DO NOT INSTALL MORE THAN (10) NOTIFICATION APPLIANCES ON ANY SINGLE CLASS "A" SIGNAL CIRCUIT.
DO NOT EXCEED 400 FT. OF NO. 14 WIRE IN THE TOTAL LOOP.
B. NFPA ALLOWS NOTIFICATION APPLIANCES TO BE MOUNTED AT A HEIGHT RANGE BETWEEN 80" TO 96"
ABOVE FINISH FLOOR. THE PREFERRED HEIGHT IS 80". IF THIS CONFLICTS WITH OTHER TRADES OR ROOM
FURNISHINGS, LOCATE AS CLOSE TO 80" AS POSSIBLE, NOT EXCEEDING 96". ALL NOTIFICATION
APPLIANCES IN A COMMON ROOM OR LINE OF SIGHT SHALL BE LOCATED AT A COMMON HEIGHT.
C. MOUNT PULL STATIONS AT 46-48" A.F.F. TO THE OPERATING HANDLE TO MEET ADA REQUIREMENTS.
D. DO NOT CONNECT THE FIRE ALARM SYSTEM TO ANY DEVICE WHICH HAS A POWER HELD
CONTACTS.(FLOW, TAMPER, HOOD SYSTEM, DUCT DETECTOR, ETC..FALSE ALARM WILL OCCUR.
E. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL CONDUCTOR QUANTITIES PER FIRE ALARM
SYSTEM SUPPLIER, AND AS PER NFPA AND NEC REQUIREMENTS.
F. DO NOT INSTALL ANY SMOKE OR HEAT DETECTORS WITHIN 3 FEET OF ANY AIR DIFFUSER.
G. DO NOT EXCEED 2500 FEET ON ANY ADDRESSABLE DEVICE RUN. DO NOT EXCEED 120 DEVICES ON ANY
ONE ADDRESSABLE DEVICE RUN.
H. ALL AIR HANDLING EQUIPMENT 2000 CFM OR MORE MUST BE SHUT DOWN UPON FIRE ALARM AS PER LIFE
SAFETY CODES.
I. ALL CLASS "B" INITIATING CIRCUITS WITH ADDRESSABLE DEVICES NEED EOLR. (END OF LINE RESISTORS).
J. IN CORRIDORS, NOTIFICATION APPLIANCES MUST BE LOCATED WITHIN 15' FROM ENDS OF CORRIDORS
AND A MAXIMUM OF 100' SPACING.
K. NOTIFICATION APPLIANCES TO BE SYNCHRONIZED TO PROVIDE A 3-3-3 TEMPORAL PATTERN.
L. ALL WIRING AND CONDUIT ROUTING TO BE AS DESCRIBED ON SUPPLIED SHOP DRAWINGS. FIRE ALARM
PLAN IS SHOWN FOR GENERAL LOCATION AND LAYOUT ONLY.
M. THE FIRE ALARM SYSTEM TO BE IN COMPLIANCE WITH ALL APPLICABLE LOCAL, STATE AND ADA
REQUIREMENTS.
N. ELECT. CONTR. TO CONNECT SPRINKLER SYSTEM TAMPER SWITCHES AND FLOW VALVES TO FIRE ALARM
SYSTEM AS REQUIRED. SEE FIRE SPRINKLER SYSTEM DRAWINGS FOR EXACT LOCATIONS AND
QUANTITIES.
GENERAL FIRE ALARM SYSTEM NOTES
LIGHTING SYMBOL SCHEDULE
NOTE: ALL SYMBOLS MAY NOT BE USED
SYMBOL DESCRIPTION
PARKING AREA POLE LIGHT, SINGLE OR DOUBLE HEAD AS INDICATED ON
DRAWINGS. REFER TO LIGHT POLE DETAIL FOR POLE INFORMATION.
2X4 FLUORESCENT OR LED FIXTURE
2X2 FLUORESCENT OR LED FIXTURE
SURFACE MOUNTED FLUORESCENT OR LED FIXTURE
STRIP FLUORESCENT OR LED FIXTURE
WALL MOUNTED FLUORESCENT OR LED FIXTURE
EXTERIOR WALL MOUNTED FIXTURE
ROUND RECESSED FIXTURE
SURFACE OR PENDANT FIXTURE
LIGHT FIXTURE SUBSCRIPTS
NL NIGHT-LIGHT(CONNECT TO UNSWITCHED LEG OF CIRCUIT)
EXIT SIGN, WALL OR CEILING MOUNTING AS REQUIRED (SINGLE OR DOUBLE FACE)
DIRECTIONAL CHEVRONS AS INDICATED; CONNECT TO UNSWITCHED LEG OF LIGHTING
CIRCUIT THAT IS IN THE SAME AREA AS THE EXIT SIGNS.
SHADED FIXTURE INDICATES AN EMERGENCY FIXTURE. PROVIDE WITH EMERG. BATTERY
PACK OR CONNECT TO EMERGENCY POWER SYSTEM (WHERE APPLICABLE). CONNECT
BATTERY PACK TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT SERVES THE SAME
AREA AS THE EMERGENCY FIXTURE. PROVIDE WITH TEST LIGHT AND SWITCH.
CEILING MOUNTED OCCUPANCY SENSOR, REFER TO OCCUPANCY SENSOR/SWITCH
SCHEDULE FOR SENSOR TYPE AND ADDITIONAL INFORMATION.
SWITCH MOUNTED OCCUPANCY SENSOR, LOW VOLTAGE SWITCHPOD OR DIMMER
SWITCH, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR TYPE AND
ADDITIONAL INFORMATION.
SINGLE-POLE SWITCH (SEE SUB-SCRIPTS BELOW FOR ADDITIONAL INFORMATION)
SWITCH SUBSCRIPTS
3 3-WAY SWITCH
4 4-WAY SWITCH
D DIMMER SWITCH (COMPATIBLE W/ LOAD & LTG TYPES)
FT FAN TIMER, 10/20/30/60 MIN. ELECTRONIC
(INTERMATIC MODEL EI210 SERIES)
P PILOT LIGHTED SWITCH
F1 LIGHT FIXTURE TYPE DESIGNATION
S
###
WALL OR CEILING MOUNTED EMERGENCY LIGHTING UNIT W/BATTERY PACK
CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS
THE EMERGENCY LIGHT.
LV LOW-VOLTAGE SWITCH (PER DWG'S)
T THERMAL-OVERLOAD SWITCH
M SWITCH SUPPLIED WITH EQUIPMENT,
INSTALLED BY E.C.
WP WEATHERPROOF
2P DOUBLE POLE, SINGLE THROW SWITCH
GENERAL LIGHTING NOTES:
A. SYMBOLS SHOWN ABOVE MAY NOT REPRESENT ALL LIGHT FIXTURES USED ON PROJECT, REFER TO
LIGHT FIXTURE SCHEDULE FOR ACTUAL FIXTURE INFORMATION INCLUDING FIXTURE TYPE, LAMPING,
MOUNTING AND ETC.
B. JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE
FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT
FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING".
C. IN GENERAL ALL SWITCH-LEG CONDUCTORS MAY NOT BE SHOWN ON DRAWINGS; E.C. SHALL PROVIDE
AND INSTALL CONDUCTORS AS REQUIRED TO ACHIEVE CONTROL SCHEMES INDICATED AND
DESCRIBED ON DRAWINGS. INCLUDING ALL 0 - 10V DIMMING CONTROLS BETWEEN SWITCH AND
FIXTURES.
D. ALL BATTERY EXIT SIGNS AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF
THE LIGHTING CIRCUIT IN THE AREA.
###
F
M
POWER SYMBOL SCHEDULE
NOTE: ALL SYMBOLS MAY NOT BE USED
SYMBOL DESCRIPTION
ELECTRICAL SWITCHBOARD EQUIPMENT, (SEE POWER RISER AND PANEL SCHEDULES
FOR ADDITIONAL INFORMATION)
'MSB'
'T##'DRY-TYPE TRANSFORMER, (SEE POWER RISER FOR ADDITIONAL INFORMATION)
'LA'
ELECTRICAL PANELBOARD, (SEE POWER RISER AND PANEL SCHEDULES
FOR ADDITIONAL INFORMATION)
DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED
TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X30A/3P/3R
FUSED DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED
TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X30A/3P/3R
(30A FUSES)
COMBINATION STARTER & FUSED DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED.
TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X
J
JUNCTION BOX
CR = CORD REEL; SEE DRAWINGS FOR INFORMATION
CD = CORD DROP; SEE DRAWINGS FOR INFORMATION
EQUIPMENT CONNECTION; COORDINATE CONNECTION WITH EQUIPMENT
PRIOR TO ROUGH-IN
MOTOR CONNECTION
POWER AND/OR DATA SERVICE POLE
FLOORBOX (SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION)
PUSHBUTTON STATION
FB#
SPECIAL RECEPTACLE (COORDINATE NEMA TYPE WITH EQUIP.)
(REFER TO PANEL SCHEDULES FOR AMPS)
CEILING MOUNTED DUPLEX RECEPTACLE (COORDINATE PLACEMENT WITH
CEILING EQUIPMENT PRIOR TO ROUGH-IN)
DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT
GFCI-TYPE DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT
DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT
GFCI-TYPE DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED
BELOW 5FT.
RECEPTACLE AND EQUIPMENT SUBSCRIPTS
AC ABOVE COUNTER
WP WEATHERPROOF (UL LISTED
WEATHER-RESISTANT)
42"MOUNTING HEIGHT AFF OR AFG
IG ISOLATED GROUND
S SURGE-PROTECTION TYPE
REF REFRIGERATOR
W WASHING MACHINE
D DRYER (30A-240V RATED RECPT.)
M MICROWAVE
HVAC THERMOSTAT OR SENSOR; PROVIDE & INSTALL BACKBOX,3/4" CONDUIT AND
CONDUCTORS TO ASSOCIATED HVAC UNIT. COORDINATE EXACT LOCATION & SIZE AND
NUMBER OF CONDUCTORS WITH M.C.
T SOR
30A/3P/3R
SIZE 1
(30A FUSES)
SMALL EXHAUST FAN CONNECTION
TV 120V RECEPT. FOR TV; VERIFY HEIGHT WITH ARCH.
DRAWINGS & ELEVATIONS
USB 120V RECPT. WITH USB CHARGING PORTS
DW/DISP DISHWASHER/DISPOSER, SPLIT-WIRE RECEPT. HALF TO
BE CONTROLLED BY SWITCH FOR DISPOSER.
(COORDINATE W/ MILLWORK AND INSTALL PER
NEC 422.16(B)(2)).
M/R MICROWAVE/RANGE HOOD (COORDINATE W/ MILLWORK)
R ELECTRIC RANGE (50A-240V RATED RECPT.)
GENERAL SPECIAL SYSTEM NOTES:
A. ALL DEVICES SHOWN AT OR NEAR MILLWORK/CASEWORK SHALL BE COORDINATED WITH THE
ARCHITECTURAL ELEVATION DRAWINGS AND MILLWORK INSTALLER TO INSURE PROPER MOUNTING
HEIGHTS. CONTRACTOR SHALL ADJUST DEVICES AS NECESSARY IN ORDER TO POSITION DEVICES SUCH
THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS OR BE DIRECTLY ABOVE SINKS OR MIDWAY
BETWEEN TILEWORK/WALL OR WAINSCOATING, ETC.
B. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL A GFCI TYPE RECEPTACLE FOR ALL
RECPTACLES SHOWN IN TOILET RMS, BATHROOMS, KITCHENS/SERVING AREAS, ROOFTOP, OUTDOORS
OR WITHIN 6FT OF ANY SINK, BASIN, TUB OR FLOOR SINK AND ALL OTHER AREAS DEFINED BY THE NEC.
SPECIAL SYSTEMS SYMBOL SCHEDULE
NOTE: ALL SYMBOLS MAY NOT BE USED
SYMBOL DESCRIPTION
DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW)_D-X
TELEPHONE OUTLET; _= # OF TELEPHONE CABLES, X=CONDUIT SIZE
(SEE NOTES 1,2,3 BELOW)
_T-X
TELEPHONE/DATA OUTLET; _= # OF TELEPHONE/DATA CABLES, X=CONDUIT SIZE
(SEE NOTES 1,2,3 BELOW)
_T/_D-X
CEILING MOUNTED DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE
(SEE NOTES 1,2,3 BELOW)
_D-X
A. COMMUNICATIONS CABLES SHALL HAVE BENDS NO GREATER THAN 90 DEG.
B. CONDUITS FOR COMMUNICATIONS CABLING SHALL HAVE A MAXIMUM BEND RADIUS NOT MORE THAN 10X
THE DIAMETER OF THE CONDUIT.
C. ALL COMMUNICATIONS CONDUITS SHALL BE TERMINATED WITH AN INSULATED NON-METALLIC BUSHING
AT BOTH ENDS.
D. COMMUNICATIONS CONDUITS SHALL HAVE NO MORE THAN (2) 90'S WITHOUT A PULLBOX. PULL BOXES
SHALL BE LOCATED IN ACCESSIBLE LOCATIONS AND SHALL BE SIZED AT LEASED 12X THE LARGEST
CONDUIT DIAMETER IN LENGTH AND MIN, 4" DEEP AND 8" WIDE.
E. IT SHALL BE THE RESPONSIBILITY OF THE E.C. TO INSURE THAT THE PATHWAY FOR THE DATA CABLING
DOES NOT CREATE CABLE LENGTHS TO EXCEEDS THE LENGTH OF 295FT FROM OUTLET TO PATCH
PANEL, THIS INCLUDES SERVICE LOOPS AND PATCH CORDS.
F. WHERE CABLE TRAY IS UTILIZED IN THE PROJECT. COMMUNICATION CONDUITS ENDING AT THE CABLE
TRAY SHALL EXTEND 1" OVER THE SIDE INTO THE TRAY.
GENERAL SPECIAL SYSTEM NOTES:
###_D-X
SPECIAL SYSTEMS NOTES:
1. UTILIZE 4 11/16" DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO ABOVE NEAREST ACCESSIBLE
CEILING OR DATA RACK, TERMINATE WITH INSULATED THROAT BUSHING. PROVIDE QTY OF CABLES
INDICATED FROM OUTLET TO NEAREST TELE/DATA ROOM. SEE DWGS FOR ADDITIONAL INFORMATION.
UTILIZE J-HOOKS 3FT ON CENTER FOR SUPPORT OF CABLING WHERE CABLE TRAY IS NOT
INSTALLED/SPECIFIED.
2. CONDUIT SIZE ('X' FROM ABOVE); 2=1/2", 3=3/4", 4=1", 5=1-1/4", 6=1-1/2"
3. BLANK (NO LABEL) = 4-11/16" DEEP BOX WITH REQUIRED MUDRING AND 1" CONDUIT TO ABOVE NEAREST
ACCESSIBLE CEILING/CABLE TRAY, TERMINATE WITH INSULATED
THROAT BUSHING, PROVIDE PULL STRING. (UNLESS OTHERWISE NOTED)
WALL/FLOOR ELECTRICAL PATHWAY SLEEVE;
INSTALL THROUGH WALL OR FLOOR AS INDICATED. SLEEVES SHALL BE ABOVE
ACCESSIBLE CEILINGS IN ACCESSIBLE LOCATION, FIELD VERIFY EXACT LOCATION TO
AVOID CONFLICT WITH OTHER TRADES AND UTILITIES. IF WALL/FLOOR IS NOT FIRE RATED
E.C. MAY UTILIZED EMT CONDUIT SLEEVES OF EQUAL SIZE. REFER TO ARCHITECTURAL
DRAWINGS FOR FIRE RATINGS.
(qty) = QUANTITY OF SLEEVES AT LOCATION
EP2 = 2" HILTI SPEED SLEEVE CP-653-BA
EP4 = 4" HILTI SPEED SLEEVE CP-653-BA
###
FB#
_D-X
ELECTRICAL FLOORBOX
REFER TO "ELECTRICAL FLOORBOX SCHEDULE" FOR INFORMATION.
_= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW)
TV AND/OR AV BOX; WITH POWER, DATA AND/OR AV CONNECTIVITY
### = BOX ID: REFER TO "ELECTRICAL AV/TV BOX SCHEDULE" FOR INFORMATION.
_= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTE #2 BELOW)
INSTALL CONDUIT (SIZE AS INDICATED) FROM BOX TO NEAREST ACCESSIBLE CEILING
SPACE W/ DATA CABLING/TERMINATIONS AS INDICATED ON DRAWINGS.
WALL
###
FLOOR
(qty)
(qty)
A. E.C. SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL MECHANICAL
EQUIPMENT AND ELECTRICAL CONNECTIONS.
B. E.C. SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL
PANELS OR CABINETS. SEE ELECTRICAL EQUIPMENT CLEARANCE DETAIL.
C. INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE.
ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED.
D. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN(S) FOR EXACT FIXTURE LOCATIONS, CEILING
TYPES, ETC.
E. E.C. SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED FOR ALL ELECTRICAL EQUIPMENT.
F. CONFIRM EXACT LOCATIONS OF ALL TELEPHONE/DATA OUTLETS WITH OWNER PRIOR TO ROUGH-IN.
G. LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TO DOOR FRAME AS
POSSIBLE, SO AS NOT RO INTERFERE WITH ROOM CABINETS, ETC.
H. SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING.
I. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR WORK AND PAY ASSOCIATED
FEES.
J. MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLING AND ELECTRONIC BALLASTS.
K. UNLESS SPECIFICALLY INDICATED OTHERWISE, E.C. SHALL COORDINATE WITH ANY SPECIAL SYSTEMS
SUPPLIER/SHOP DRAWINGS; DENTAL, MEDICAL, KITCHEN, SPECIALIZED EQUIPMENT, ETC. FOR THE EXACT
ROUGH-IN REQUIREMENTS FOR THEIR EQUIPMENT. ALSO UNLESS INDICATED OTHERWISE, THE E.C. TO
BE RESPONSIBLE FOR FINAL ELECTRICAL CONNECTIONS TO ALL SPECIAL EQUIPMENT.
L. ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IF ANY SURFACE
WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION.
M. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE
EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY
PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS.
N. DATA CABLING SYSTEM PRE-INSTALLATION CONFERENCE:
1. E.C. SHALL SCHEDULE A MEETING A MINIMUM OF FIVE CALENDAR DAYS PRIOR TO BEGINNING DATA
CABLING INSTALLATION . ATTENDEES SHOULD INCLUDE OWNER’S REP., ENGINEER, GC, EC AND
CABLING SUB. REFER TO SECTION 26 6210(1.4)(E) FOR ADDITIONAL INFORMATION.
PROJECT GENERAL NOTES:
ROCKY MOUNTAIN POWER CO.
WWW.ROCKYMOUNTAINPOWER.NET
CONTACT: DAN KUHL (503) 308-0233
dan.kuhl@evergreen-efficiency.com
UTILITY LIGHTING REBATES & INCENTIVES:
IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PREPARE ALL REQUIRED
APPLICATIONS AND INFORMATION REQUIRED TO PROVIDE THE OWNER WITH THE MAXIMUM AMOUNT OF
REBATE DOLLARS FROM THE LOCAL UTILITY COMPANY. THE ELECTRICAL CONTRACTOR SHALL SUBMIT
VERIFICATION OF THE UTILITY COMPANY PRE-APPLICATION APPROVAL PRIOR TO ORDERING ANY MATERIALS.
VISIT THE FOLLOWING UTILITY CO. WEBSITES FOR INFORMATION:
TYPICAL DEVICE MOUNTING HEIGHTS:
GENERAL COORDINATION NOTE:
GENERAL DETAIL NOTES:
FINISH FLOOR
1' - 6''
THERMOSTAT OR SENSORVERIFY WITH M.C. PRIOR TO
LIGHT SW.
(OR AS NOTED)
* 4' - 0''
* 3' - 6''
(OR AS NOTED)
RECEPTACLE
@ MILLWORK
BACKSPLASH
CA
B
.
D
I
M
E
N
S
I
O
N
S
PE
R
A
R
C
H
.
D
E
T
A
I
L
6"
CABINET
*E.C. SHALL COORDINATE ALL DEVICE
MOUNTING HGTS. AND EXACT LOCATION
WITH ARCHITECTURAL INTERIOR
ELEVATIONS REPORT CONFLICTS TO
ARCHITECT **PRIOR TO ROUGH-IN**
ROUGH-IN.
TYPICAL FOR ALL DEVICES
MOUNTED ABOVE COUNTER
(ie C.O.'S, DATA, PHONE etc.)
A.
B.
C.
D.
ALL MOUNTING HEIGHTS TYPICAL UNLESS
NOTED OTHERWISE.
COORDINATE OUTLET HEIGHTS WITH
ARCHITECTS MILLWORK DWGS. TO INSURE
THAT OUTLETS WILL NOT FALL BEHIND
CABINETS, BACKSPLASHES, OR INTERFERE
WITH WAINSCOTING, ETC.
ALL SWITCHES AND THERMOSTATS TO BE
MOUNTED AS CLOSE TO DOOR JAMS AS
POSSIBLE. COORDINATE ALL DEVICES WITH
ARCHITECTURAL PLANS AND DETAILS.
COORDINATE LIGHT SWITCH & OUTLET
HEIGHTS WITH ARCHITECTURAL
WAINSCOTING AND OR TILE WORK SO AS
NOT TO FALL MIDWAY IN THESE FINISHES.
FIRE
6' - 8''
FIRE ALARM NOTIFICATION
DEVICE
FIRE
MANUAL PULL STATION
HANDLE SHALL BE
BETWEEN 42" & 48" AFF CABINET
RECEPT.
TELE/DATA
OUTLET
TV
OUTLET
ELECTRICAL EQUIP. CLEARANCE
ELECTRICALEQUIPMENT
NO
T
E
#
1
N O T E #4
NOTE#3
NOTE#2
NOTES:
1. THE MINIMUM HEADROOM OF WORKING SPACE SHALL BE 6 1/2FT.
2. THE WIDTH OF THE WORKING SPACE SHALL BE THE WIDTH OF THE EQUIPMENT OR 30", WHICHEVER IS
GREATER. THE PANEL DOOR SHALL OPEN AT LEAST 90 DEGREES.
3. ALL CIRCUIT BREAKERS, WHEN IN THIER HIGHEST POSITION, SHALL NOT BE MORE THAN 6FT 7 IN. ABOVE
THE FINISHED FLOOR.
4. 3FT CLEARANCE IF 0-150V TO GROUND, 3.5FT CLEARANCE IF 151-600V TO GROUND. 4FT IF EXPOSED LIVE
PARTS ON BOTH SIDES OF THE WORKING SPACE.
GENERAL NOTES:
A. ALL WORKING SPACE CLEARANCES ARE FROM THE FACE OF THE EQUIPMENT.
13053
STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP
OFESSIONALENGIN
EE
R
1823 E. Center
Pocatello, Idaho 83201
tel (208) 232-4439
www.payneengineeringinc.com
Engineering Inc.
Consulting Engineers
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
P.E. #:2227
04/18/22
4/
1
5
/
2
0
2
2
1
0
:
2
5
:
1
3
A
M
E0.0
ELECTRICAL
SYMBOLS &
DETAILS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
no. description date
S CD2
WP
1
'H'
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(3/E2.0)
F1
FX1 FX1
FX1
FX1
FX2
F2F2F2F2
F2 F2 F2 F2
F3E
9' -6"F3E
9' -6"
F4F4F4
BCDEG
1
5
6
10
3
F
7
A
2
9
4
8
FX2 FX2
1 1
F6
F6
1
F6
F6
1
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(3/E2.0)
FX1 FX1FX2
F2F2F2F2
F2 F2 F2 F2
FX2 FX2
BCDEG
1
5
6
10
3
F
7
A
2
9
4
8
F4 F4
FX2 FX2
F5
16' -0"
1F5
16' -0"
1
F5
16' -0"1F5
16' -0"1
13053
STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP
OFESSIONALENGIN
EE
R
1823 E. Center
Pocatello, Idaho 83201
tel (208) 232-4439
www.payneengineeringinc.com
Engineering Inc.
Consulting Engineers
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
P.E. #:2227
04/18/22
4/
1
5
/
2
0
2
2
1
0
:
2
5
:
1
7
A
M
E1.0
1ST & 2ND
FLOOR LIGHTING
PLANS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT
GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH
THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT
LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL
SYSTEMS, ETC.
GENERAL NOTES:
KEY NOTES:#
SCALE: 1/8" = 1'-0"1 OVERALL 1ST FLOOR LIGHTING PLAN
16'8'0"
FIRE ALARM SYSTEM SHALL BE DESIGN BUILD BY THE ELECTRICAL
CONTRACTOR. PROVIDE AND INSTALL AS REQUIRED BY CURRENT ADOPTED
INTERNATIONAL FIRE CODE AND LOCAL AHJ REQUIREMENTS. PROVIDE ALL
DOCUMENTATION, DRAWINGS, VOLTAGE DROP AND BATTERY CALCULATIONS
AND ECT. TO THE CITY FOR PERMITTING AND INSTALLATION.
A. NFPA ALLOWS NOTIFICATION APPLIANCES TO BE MOUNTED AT A HEIGHT
RANGE BETWEEN 80" TO 96" ABOVE FINISH FLOOR. THE PREFERRED HEIGHT
IS 80". IF THIS CONFLICTS WITH OTHER TRADES OR ROOM FURNISHINGS,
LOCATE AS CLOSE TO 80" AS POSSIBLE, NOT EXCEEDING 96". ALL
NOTIFICATION APPLIANCES IN A COMMON ROOM OR LINE OF SIGHT SHALL BE
LOCATED AT A COMMON HEIGHT.
B. MOUNT PULL STATIONS AT 46-48" A.F.F. TO THE OPERATING HANDLE TO MEET
ADA REQUIREMENTS.
C. IN CORRIDORS, NOTIFICATION APPLIANCES MUST BE LOCATED WITHIN 15'
FROM ENDS OF CORRIDORS AND A MAXIMUM OF 100' SPACING.
D. PROVIDE THE REQUIRED CANDELA RATING OF ALL NOTIFICATION
APPLIANCES ACCORDING TO ROOM SIZE,ETC.
E. NOTIFICATION APPLIANCES TO BE SYNCHRONIZED TO PROVIDE A 3-3-3
TEMPORAL PATTERN.
F. ALL DWELLING UNITS SHALL BE PROVIDED WITH MULTI-STATION SMOKE &
CARBON MONOXIDE DETECTORS AND LOW FREQUENCY NOTIFICATION
DEVICES IN COMPLIANCE WITH NFPA 72, ADA UNITS SHALL BE PROVIDED
WITH AUDIBLE AND VISIBLE NOTIFICATION DEVICES.
G. ALL NOTIFICATION DEVICES LOCATED IN SLEEPING ROOMS SHALL BE 177
CANDELA.
FIRE ALARM SYSTEM:
LIGHTING FIXTURE SCHEDULE
TYPE DESCRIPTION MTG VOLTS LUMENS
COLOR
TEMP.(K) MFGR. CATALOG #
APPROVED
MFGR'S NOTES
F1 4FT LED STRIP, 0-10V DIMMING SURFACE 120 4500 4000 LITHONIA MNSL-L48-2LL-MVOLT-40K-80CRI-M6 COOPER
F2 4FT LED WRAPAROUND, FIELD
SELECTABLE LUMENS
SURFACE 120 5000 4000 LITHONIA FML4W-48-ALO6-SEF-840-MVOLT COOPER
F3E EXTERIOR LED WALL PACK, W/
INTEGRAL EMERG. BATTERY PACK
WALL 120 6000 4000 LITHONIA WDGE2 LED-P5-40K-VF-MVOLT-E20WC-SCBA COOPER 3
F4 6" ROUND SURFACE LED
DOWNLIGHT, DIMMABLE
SURFACE 120 1200 4000 COOPER LTG SLD612-8-40-WH LITHONIA
F5 4" DIA. LED WALL CYLINDER,20 DEG.
UP/DWN DIST. IP66 RATED
WALL 120 3000 UP
3000 DWN
4000 GOTHAM LTG ICO4UDWC-40/30-AR-LSS-20D-SHLD-SCBA//U30LM-U20D
-USHLD-SCBA-120-GZ10-JBX-IP66-SCBA
COOPER 3
F6 GOOSENECK SIGN LED SIGN LIGHT
W/ 10" DIA. SHADE
WALL
ABOVE
SIGN
120 1250 4000 BARN LIGHT ASFC10-SBCA-G11-SCBA-SWK-SCBA-LED16-4000K-DL
FX1 EXIT SIGN/EM LIGHT COMBO W/
90MIN BATTERY,THERMOPLASTIC,
GREEN LED, SINGLE/DOUBLE FACE
WALL OR
CEILING
120-277 N/A N/A LITHONIA LHQM LED-G-SD COOPER
FX2 WALL MOUNTED LED EMERGENCY
LIGHT
WALL AT
7'-6" AFF
120-277 N/A N/A LITHONIA ELM6L-UVOLT-LTP-SDRT COOPER
1. REFER TO DRAWINGS FOR FIXTURES REQUIRED TO HAVE 0-10V OR STEP-LEVEL DIMMING CONTROL. PROVIDE FIXTURE(S) WITH LED DRIVER(S)
AND REQUIRED DIMMING/SWITCH-LEG CONDUCTORS BETWEEN SWITCH(ES) AND FIXTURE(S) TO PROVIDE CONTROL AS INDICATED ON
DRAWINGS.
2. FIXTURE TO BE CONTINUOUS ROW MOUNTED, LENGTH AS INDICATED ON DRAWINGS. PROVIDE REQUIRED ACCESSORIES/CONNECTORS FOR
CONTINUOUS ROW MOUNTING.
3. SCBA - STANDARD COLOR BY ARCHITECT/OWNER (COORDINATE COLOR WITH ARCHITECT/OWNER PRIOR TO ORDERING.)
LIGHT FIXTURE SCHEDULE NOTES:
• LIGHTING FIXTURES INDICATED IN SCHEDULE ARE BASIS OF DESIGN, ALTERNATE MANUFACTURERS SHALL BE PRE-APPROVED BY ADDENDUM.
ALTERNATE MANUCATURERS SHALL SUBMIT PER-APPROVALS TO ENGINEER A MINIMUM OF 10 DAYS PRIOR TO PROJECT BID DATE.
GENERAL LIGHTING SCHEDULE NOTES:
LIGHTING CONTROL/OCCUPANCY SENSOR SCHEDULE
TYPE DESCRIPTION MFGR. CATALOG #
APPROVED
EQUALS NOTES
OCC. SENSORS - CEILING (LINE VOLTAGE)
CD2 DUAL-TECHNOLOGY, LINE VOLTAGE, SMALL MOTION 800W
MAX LOAD
SENSOR SWITCH CMR PDT 9 COOPER,
WATTSOPPER,
HUBBELL
OCC. SENSORS - WALL MOUNTED
WP1 PASSIVE-INFRARED, 1-POLE, NEUTRAL REQUIRED SENSOR SWITCH WSX-** COOPER,
WATTSTOPPER,
HUBBELL
2
1 EXTERIOR LIGHTING TO BE CONTROLLED VIA
PHOTOCELL/TIMECLOCK FOR DUSK-TILL-DAWN OPERATION.
INSTALL TIMECLOCK IN FIRE RISER ROOM, ROUTE EXTERIOR
LTG CIRCUIT TIMECLOCK. PROGRAM ON/OFF TIMES AS
DIRECTED BY OWNER. PROVIDE ADDITIONAL UNSWITCHED
LEG FOR CONNECTION TO EMERG. BATTERY PACK IN
EMERGENCY FIXTURES.
SCALE: 1/8" = 1'-0"2 OVERALL 2ND FLOOR LIGHTING PLAN
16'8'0"
1. PROVIDE ADDITIONAL POWER PACKS; SENSOR SWITCH PP20 AS NEED FOR QTY OF OCCUPANCY SENSORS/SWITCHES.
2. DEVICE COLOR SHALL MATCH WIRING DEVICES; REFER TO SPECIFICATIONS.
3. REFER TO MANUFACTURER DOCUMENTATION FOR QTY AND SIZE OF CONDUCTORS BETWEEN LOW VOLTAGE SWITCH, SENSOR(S) AND
POWER/RELAY PACKS.
4. PROVIDE SECONDARY RELAY PACK; SENSOR SWITCH SP20 AS NEEDED TO PROVIDE DUAL-LEVEL SWITCHING OF FIXTURES.
5. PROVIDE 0-10V DIMMING CONDUCTORS (GRAY & VIOLET) BETWEEN SWITCH AND LIGHT FIXTURES FOR DIMMING CONTROL.
6. PROGRAM ON/OFF TIMES OF RELAY'S AS DIRECTED BY OWNER. PROVIDE COMMISSIONING AS INDICATED IN GENERAL NOTES BELOW.
7. CUSTOM WALL STATION ENGRAVINGS IS REQUIRED FOR WALL STATION(S) AND SHALL BE SPECIFIED/COORDINATED WITH OWNER AFTER
PROGRAMING OF SYSTEM.
CONTROL & OCCUPANCY SENSOR SCHEDULE NOTES:
• E.C. SHALL BE RESPONSIBLE FOR THE PROGRAMMING/COMMISSIONING OF THE LIGHTING CONTROL SYSTEMS TO FUNCTION AS INDICATED ON
THE DRAWINGS AND SHALL INCLUDE ALL REQUIRED COST IN THE BASE BID. FOR AREAS WITH DAYLIGHTING CONTROL, THE DAYLIGHTING SET-
POINTS SHALL BE COORDINATED WITH THE OWNER FOR EACH AREA PRIOR TO FINAL PROGRAMMING OF THE DAYLIGHTING SENSOR(S). ALL
PROGRAMMING/COMMISSIONING SHALL BE DONE BY A FACTORY CERTIFIED OR TRAINED PERSON.
• LIGHTING IS SPACES WITH WIRELESS CONTROLS SHALL BE FIELD TUNED TO FOOTCANDLE LEVELS THAT ARE SATISFACTORY TO THE OWNER
DURING PROGRAMMING AND COMMISSIONING OF THE WIRELESS CONTROL SYSTEM.
GENERAL LIGHTING CONTROL NOTES:
no. description date
P
FS
TS
'METER-PACK
MP-1'
'H'
'1B''1B'
'1B''1B'
'2B''2B'
'2B'
'3B'
WP WP
'FACP'
REFER TO FIRE
ALARM SYSTEM NOTES
EH-1
EH-2 EH-2
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(3/E2.0)
'TTB'
1
2
3
4
(A/E1.1)
5
BCDEG
1
5
6
10
3
F
7
A
2
9
4
8
WH-2
H-16
H-8#10'S
H-18,20#10'S
H-12#10'S
'1B''1B'
'1B''1B'
'2B''2B'
'2B'
'3B'
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(3/E2.0)
BCDEG
1
5
6
10
3
F
7
A
2
9
4
8
6"
3/4" C., 1#6 B.C. GRND.
CONNECT TO BLDG. GROUND
SYSTEM
FINISH FLOOR
TYPICAL CONDUIT/CABLING
TO UNIT MEDIA CENTERS
REFER TO TYP. UNIT PLANS
4'X8'X3/4" PLYWOOD
PRIME & PAINT W/TWO
COATS GREY ENAMEL
(INSTALL ON WALLS AS
INDICATED ON PLANS)
ANCHOR SECURELY TO
WALL W/ CONST.
ADHESIVE.
DOUBLE-DUPLEX
OUTLET(S) PER PLANS
120V CIRCUIT
PER PLANS
PULL CORD
INCOMING UTILITY
SERVICECONDUIT(S)
WITH INSULATED BUSHING.
SEE SITE PLAN FOR SIZE & QTY
GROUND BAR
(SQ. D #PK27GTA)
TELEPHONE, DATA,
TV EQUIPMENT (TYP)
ENTRANCE
CONDUIT(S)
4" SQUARE
BOX
RAISED RING
TO SUIT WALL
RECEPTACLE - 20AMP
RATED - SEE SPECIFICATIONS.
NORMAL POWER COLOR - (SEE SPEC'S)
COVER PLATE - STYLE & COLOR
TO BE AS PER SPECIFICATIONS.
CIRCUIT NUMBER TO BE WRITTEN ON
BACK OF COVER W/FELT-TIP MARKER
GREEN INSULATED
GROUND CONDUCTOR
13053
STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP
OFESSIONALENGIN
EE
R
1823 E. Center
Pocatello, Idaho 83201
tel (208) 232-4439
www.payneengineeringinc.com
Engineering Inc.
Consulting Engineers
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
P.E. #:2227
04/18/22
4/
1
5
/
2
0
2
2
1
0
:
2
5
:
1
9
A
M
E1.1
1ST & 2ND
FLOOR PWR
PLANS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT
GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH
THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT
LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL
SYSTEMS, ETC.
GENERAL NOTES:
KEY NOTES:#
16'8'0"
16'8'0"
FIRE ALARM SYSTEM SHALL BE DESIGN BUILD BY THE ELECTRICAL
CONTRACTOR. PROVIDE AND INSTALL AS REQUIRED BY CURRENT ADOPTED
INTERNATIONAL FIRE CODE AND LOCAL AHJ REQUIREMENTS. PROVIDE ALL
DOCUMENTATION, DRAWINGS, VOLTAGE DROP AND BATTERY CALCULATIONS
AND ECT. TO THE CITY FOR PERMITTING AND INSTALLATION.
A. NFPA ALLOWS NOTIFICATION APPLIANCES TO BE MOUNTED AT A HEIGHT
RANGE BETWEEN 80" TO 96" ABOVE FINISH FLOOR. THE PREFERRED HEIGHT
IS 80". IF THIS CONFLICTS WITH OTHER TRADES OR ROOM FURNISHINGS,
LOCATE AS CLOSE TO 80" AS POSSIBLE, NOT EXCEEDING 96". ALL
NOTIFICATION APPLIANCES IN A COMMON ROOM OR LINE OF SIGHT SHALL BE
LOCATED AT A COMMON HEIGHT.
B. MOUNT PULL STATIONS AT 46-48" A.F.F. TO THE OPERATING HANDLE TO MEET
ADA REQUIREMENTS.
C. IN CORRIDORS, NOTIFICATION APPLIANCES MUST BE LOCATED WITHIN 15'
FROM ENDS OF CORRIDORS AND A MAXIMUM OF 100' SPACING.
D. PROVIDE THE REQUIRED CANDELA RATING OF ALL NOTIFICATION
APPLIANCES ACCORDING TO ROOM SIZE,ETC.
E. NOTIFICATION APPLIANCES TO BE SYNCHRONIZED TO PROVIDE A 3-3-3
TEMPORAL PATTERN.
F. ALL DWELLING UNITS SHALL BE PROVIDED WITH MULTI-STATION SMOKE &
CARBON MONOXIDE DETECTORS AND LOW FREQUENCY NOTIFICATION
DEVICES IN COMPLIANCE WITH NFPA 72, ADA UNITS SHALL BE PROVIDED
WITH AUDIBLE AND VISIBLE NOTIFICATION DEVICES.
G. ALL NOTIFICATION DEVICES LOCATED IN SLEEPING ROOMS SHALL BE 177
CANDELA.
FIRE ALARM SYSTEM:
SCALE: 1/8" = 1'-0"1 OVERALL 1ST FLOOR ELECTRICAL PLAN
SCALE: 1/8" = 1'-0"2 OVERALL 2ND FLOOR ELECTRICAL PLAN
1 NEW UNDERGROUND SECONDARY; SEE POWER RISER FOR
ADDITIONAL INFORMATION.
2 (1) 4" CONDUIT FOR TELECOMMUNICATIONS SERVICE TO
BUILDING AND (1) 2" CONDUIT FOR CABLE TV SERVICE TO
BUILDING. STUB CONDUITS TO LOCATIONS AS SPECIFIED BY
LOCAL TELEPHONE AND CABLE TV PROVIDERS, PROVIDE
WITH PULL-STRING. COORDINATE WITH LOCAL UTILITIES AS
INDICATED IN GENERAL NOTES
3 INSTALL FIRE BELL AND HORN/STROBE ABOVE FIRE DEPT.
CONNECTION; FIELD LOCATION, COORDINATE LOCATION
WITH FIRE SPRINKLER CONTRACTOR PRIOR TO ROUGH-IN.
4 PROVIDE MONITORING OF FLOW AND TAMPER SWITCHES;
VERIFY EXACT NUMBER OF SWITCHES WITH FIRE
SPRINKLER CONTRACTOR.
5 METER-PACK LOCATION IS SCHEMATIC IN NATURE, E.C.
SHALL COORDINATE LOCATION OF METER PACK WITH RMP
SITE DIST. DESIGN AND TRANSFORMER LOCATIONS.
SCALE: NONEATELEPHONE TERMINAL BOARD (TTB)
SCALE: NONEBRECEPTACLE MOUNTING DETAIL
no. description date
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(3/E2.0)
FX1 FX1FX2
F2F2F2F2
F2 F2
FX2
FX2
F2 F2 F2F2
BCDEG
1
5
6
10
3
F
7
A
2
9
4
8
FX2 FX2
'1B''1B'
'1B''1B'
'2B''2B'
'2B'
'3B'
EH-2 EH-2
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(1/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(2/E2.0)
SEE TYP.
UNIT PLAN
(3/E2.0)
BCDEG
1
5
6
10
3
F
7
A
2
9
4
8
H-14#10'S H-10#10'S
13053
STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP
OFESSIONALENGIN
EE
R
1823 E. Center
Pocatello, Idaho 83201
tel (208) 232-4439
www.payneengineeringinc.com
Engineering Inc.
Consulting Engineers
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
P.E. #:2227
04/18/22
4/
1
5
/
2
0
2
2
1
0
:
2
5
:
2
0
A
M
E1.2
3RD FLOOR
LTG/PWR PLANS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT
GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH
THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT
LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL
SYSTEMS, ETC.
GENERAL NOTES:
KEY NOTES:#
FIRE ALARM SYSTEM SHALL BE DESIGN BUILD BY THE ELECTRICAL
CONTRACTOR. PROVIDE AND INSTALL AS REQUIRED BY CURRENT ADOPTED
INTERNATIONAL FIRE CODE AND LOCAL AHJ REQUIREMENTS. PROVIDE ALL
DOCUMENTATION, DRAWINGS, VOLTAGE DROP AND BATTERY CALCULATIONS
AND ECT. TO THE CITY FOR PERMITTING AND INSTALLATION.
A. NFPA ALLOWS NOTIFICATION APPLIANCES TO BE MOUNTED AT A HEIGHT
RANGE BETWEEN 80" TO 96" ABOVE FINISH FLOOR. THE PREFERRED HEIGHT
IS 80". IF THIS CONFLICTS WITH OTHER TRADES OR ROOM FURNISHINGS,
LOCATE AS CLOSE TO 80" AS POSSIBLE, NOT EXCEEDING 96". ALL
NOTIFICATION APPLIANCES IN A COMMON ROOM OR LINE OF SIGHT SHALL BE
LOCATED AT A COMMON HEIGHT.
B. MOUNT PULL STATIONS AT 46-48" A.F.F. TO THE OPERATING HANDLE TO MEET
ADA REQUIREMENTS.
C. IN CORRIDORS, NOTIFICATION APPLIANCES MUST BE LOCATED WITHIN 15'
FROM ENDS OF CORRIDORS AND A MAXIMUM OF 100' SPACING.
D. PROVIDE THE REQUIRED CANDELA RATING OF ALL NOTIFICATION
APPLIANCES ACCORDING TO ROOM SIZE,ETC.
E. NOTIFICATION APPLIANCES TO BE SYNCHRONIZED TO PROVIDE A 3-3-3
TEMPORAL PATTERN.
F. ALL DWELLING UNITS SHALL BE PROVIDED WITH MULTI-STATION SMOKE &
CARBON MONOXIDE DETECTORS AND LOW FREQUENCY NOTIFICATION
DEVICES IN COMPLIANCE WITH NFPA 72, ADA UNITS SHALL BE PROVIDED
WITH AUDIBLE AND VISIBLE NOTIFICATION DEVICES.
G. ALL NOTIFICATION DEVICES LOCATED IN SLEEPING ROOMS SHALL BE 177
CANDELA.
FIRE ALARM SYSTEM:
SCALE: 1/8" = 1'-0"1 OVERALL 3RD FLOOR LIGHTING PLAN
16'8'0"
SCALE: 1/8" = 1'-0"2 OVERALL 3RD FLOOR ELECTRICAL PLAN
16'8'0"
no. description date
M
M
F
F/L
FT
3
3
3
3
M
M
F F/L
FT
3
3
3
M
F
FT
3
M
M
F/L
F
FT
3
3
M
F
FT
3
3
3
M
M
3
3
4 3
-
-
SEE TYP. DWELLING UNIT LOAD SCHEDULE
-
- -
-
PANEL
FEED TOP
DIMENSIONS
FEED BOTTOM
AIC RATING
AMPS
WATTS
FEEDER CONDUCTOR SIZE:
TOTAL LOAD/PHASE
REMARKS:
35
37
41
39
25
27
29
33
31
19
17
23
21
LOAD NAME
7
11
15
13
9
NO.
3
5
1
LOCATION
MAKE/MODEL
CLASS
CIR WIRE
SIZE LLAMPEA B
AMPE
LOAD/POLE
MAIN LUGS
MAIN BRKR.
BRK PO
AMPS
PO BRK
40
42
36
38
26
34
32
30
28
22
24
18
20
LOAD NAME
8
16
14
10
12
4
6
2
NO.
CIR
SURFACE
FLUSHAMPS
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WIRE
SIZE
SQ. D QO LOAD CENTER
SEE UNIT DWG.
120/208V, 1PH, 3W
TYPICAL UNIT NOTE#1
14"W x 24"H x 4"D
PROVIDE PANEL WITH A LOCKABLE COVER
LIGHTING/RECEPTS #12 Cu 20 1
SMOKE/CO2 DETECTORS #12 Cu 20 1
WATER HTR 230
**30 *
WASHING MACH. (NOTE#3) #12 Cu 20 1
DRYER (NOTE#3) #10 Cu 30 2
30 *#10 Cu**
PREPARED SPACE
SMALL APPLIANCE CRKT
LIGHTING/RECEPTS
#12 Cu201
#12 Cu201
DISHWASHER/DISPOSER#12 Cu201
RANGE HOOD/MICROWAVE#12 Cu201
HVAC UNIT (NOTE #2)### Cu##2
##***### Cu
RANGE (NOTE#3)#8 Cu402
40***#8 Cu
PREPARED SPACE
SPARE201
NOTE #1 THIS PANEL SCHEDULE IS TYPICAL AND REFERENCE FOR THE BRANCH CIRCUIT REQUIREMENTS OF THE
DWELLING UNITS; REFER TO TYPICAL DWELLING UNIT SCHEDULE FOR SERVICE/FEEDER SIZE AND MAIN
BREAKER RATING BASE ON DWELLING UNIT TYPE.
NOTE #2 1-BED UNITS F-1: 15A/2P, #12 Cu
2-BED UNITS F-2: 20A/2P, #12 Cu
3-BED UNITS F-3: 35A/2P, #8 Cu
NOTE #3 UTILIZED GFCI TYPE CIRCUIT BREAKER AS REQUIRED BY 2020 NEC.
#10 Cu
#10 Cu
TYP. APARTMENT PANEL AIC RATINGS SHALL BE
AS FOLLOWS:
FEEDER LENGTHS LESS THAN 35FT : 22k AIC
FEEDER LENGTHS GREATER THAN 35FT: 10k AIC
GENERAL LOADS
TYPICAL DWELLING UNIT EXAMPLE
1200 SQ FT UNIT X 3 VA PER SQ FT
SUB-TOTAL (HVAC LOAD)
HVAC LOADS
APPLICATION OF DEMAND FACTORS
ELECTRICAL LOAD CALCULATIONS
SERVICE SIZE
RECOMMENDED SERVICE SIZE IN AMPS
MIN. SERVICE SIZE IN AMPS (19,000VA @ 120/208 1PH. 3W)
REMAINDER (16000) @ 40%
HVAC LOAD @ 100% PER NEC
BREAKER
FIRST 10000 @ 100%
TOTAL DEMAND
GENERAL LOAD PER NEC 220.82
HVAC LOAD (HEATING & COOLING)
GENERAL LIGHTING/POWER
SMALL APPLIANCE (KITCHEN) 2-CIRCUITS
10,000 VA
19,000 VA
91 AMPS
(SEE NOTE#1)
=
=
=
=3,000 VA
3,600 VA
3,000 VA=
=
26,000 VASUB-TOTAL (GENERAL LOADS)
RANGE LOAD
DRYER
DISHWASHER
DISPOSAL
=
=
=
=
10,000 VA
5,000 VA
400 VA
1,000 VA
3,000 VA
6,400 VA
3,000 VA
SMALL APPLIANCE (LAUNDRY) 1-CIRCUITS
SMALL APPLIANCE (BATH) 1-CIRCUITS
1,500 VA=
1,500 VA=
NOTE #1 THIS CALCULATION IS A TYPICAL EXAMPLE OF THE DWELLING UNIT LOAD
CALCULATIONS USED AND IS FOR REFERENCE ONLY; REFER TO THE TYPICAL
DWELLING UNIT LOAD SCHEDULE FOR ACTUAL LOAD INFORMATION FOR THE
SPECIFIC DWELLING UNITS.
(SEE NOTE#1)
WH-1 F-1
WP
D
42"
AC
AC
AC
M/R
R
DW/DISP
TV
'1B'
'SMC'
1
AC
WH-1F-2
WP
D
42"
AC
AC
AC
M/R
R
DW/DISP
TV
AC
30"
AC
'2B'
'SMC'
1
WH-1 F-3
WP
D
42"AC
AC
AC
M/R
R
DW/DISP
TV
AC
30"
AC
'3B''SMC'
1
APARTMENT UNIT PANEL
VOLTAGE DROP SCHEDULE
208 VOLT, 1 PHASE,
#1 AL SER CABLE* - MAXIMUM LENGTH OF 200'
#1/0 AL SER CABLE* - MAXIMUM LENGTH OF 260'
#2/0 AL SER CABLE* - MAXIMUM LENGTH OF 330'
#3/0 AL SER CABLE* - MAXIMUM LENGTH OF 400'
#4/0 AL SER CABLE* - MAXIMUM LENGTH OF 500'
FEEDER SIZE TO APARTMENT UNIT PANELS SHALL BE DETERMINED FROM
THE FOLLOWING SCHEDULE, THIS TABLE IS BASED ON ALUMINUM SER
CABLE. COPPER CONDUCTORS MAY BE UTILIZED, BUT ELECTRICAL
CONTRACTOR IS RESPONSIBLE FOR VOLTAGE DROP CALCULATIONS AND
FEEDER SIZES TO ALLOW FOR A MAXIMUM OF 3% VOLTAGE DROP AT PANEL.
* GROUNDING CONDUCTOR OF SER CABLE SHALL BE PROPORTIONATELY
INCREASED IN SIZE PER NEC 250.122(B)
13053
STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP
OFESSIONALENGIN
EE
R
1823 E. Center
Pocatello, Idaho 83201
tel (208) 232-4439
www.payneengineeringinc.com
Engineering Inc.
Consulting Engineers
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
P.E. #:2227
04/18/22
4/
1
5
/
2
0
2
2
1
0
:
2
5
:
2
2
A
M
E2.0
TYPICAL UNIT
PLANS
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
A. PROVIDE ARC-FAULT PROTECTION FOR ALL 120V, 15A & 20A
BRANCH CIRCUITS AS REQUIRED BY THE NEC SECTION
210.12 AND IDAHO CODE. INCLUDING BUT NOT LIMITED TO;
DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS,
LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,
SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS,
LAUNDRY AREAS OR SIMILAR ROOMS OR AREAS.
B. PROVIDE AND INSTALL ALL REQUIRED DEVICES AND
CIRCUITS REQUIRED IN A DWELLING UNIT AS DESCRIBED BY
THE CURRENT NEC THAT IS ADOPTED BY THE LOCAL
AUTHORITY HAVING JURISDICTION; REFER TO NEC SECTION
210.11 AND 210.50.
C. TAMPER-PROOF RECEPTACLES SHALL BE INSTALLED IN ALL
AREAS OF THE DWELLING UNITS; REFER TO NEC SECTION
406.11 OF THE NEC.
D. EVEN IF SPECIFICALLY INDICATED ON THE DRAWINGS, ALL
DEVICES SHOWN AT OR NEAR MILLWORK/CASEWORK SHALL
BE COORDINATED WITH THE ARCHITECTURAL ELEVATION
DRAWINGS AND MILLWORK INSTALLER TO INSURE PROPER
MOUNTING HEIGHTS. CONTRACTOR SHALL ADJUST DEVICES
AS NECESSARY IN ORDER TO POSITION DEVICES SUCH THAT
THEY WILL NOT FALL BEHIND MILLWORK, CABINETS OR BE
DIRECTLY ABOVE SINKS OR MIDWAY BETWEEN
TILEWORK/WALL OR WAINSCOATING, ETC.
E. ALL CLOSET FIXTURES SHALL BE FULLY ENCLOSED PER THE
NEC.
F. PROVIDE GFCI RECEPTACLES AS REQUIRED BY THE NEC
WETHER SHOWN OR NOT.
G. E.C. SHALL REFER TO BUILDING FLOOR PLANS AND
ARCHITECTURAL DRAWINGS FOR SPECIFIC UNIT
ORIENTATION AND LAYOUT AS UNITS MAY BE MIRRORED OR
HAVE SLIGHT WALL MODIFICATIONS FROM TYPICAL UNIT
SHOWN. E.C. SHALL ADJUST OUTLETS, LIGHTING AND ETC.
TO MATCH ACTUAL ORIENTATION.
GENERAL NOTES:
KEY NOTES:#
8'4'0"
TYPICAL DWELLING UNIT LOAD SCHEDULE
UNIT
TYPE DESCRIPTION
UNIT
SQFT QUANTITY
GENERAL LOAD
(PER UNIT)
APPLIANCE LOAD
(PER UNIT)
HVAC LOAD
(PER UNIT)
TOTAL CONN. LOAD
(PER UNIT)
TOTAL DEMAND LOAD
(PER UNIT)
TOTAL DEMAND AMPS
(PER UNIT)
RECOMMENDED
SERVICE SIZE
BRKR
SIZE FEEDER SIZE
1B 1-BEDROOM UNIT 600 12 6300 VA 18900 VA 2000 VA 27200 VA 18080 VA 87 A 100 A 100 A #1 AL SER CABLE W/ GND
2B 2-BEDROOM UNIT 900 9 7200 VA 18900 VA 2700 VA 28800 VA 19140 VA 92 A 100 A 100 A #1 AL SER CABLE W/ GND
3B 3-BEDROOM UNIT 1100 3 7800 VA 18900 VA 5000 VA 31700 VA 21680 VA 104 A 125 A 125 A #1/0 AL SER CABLE W/ GND
SCALE: 1/4" = 1'-0"1 TYP. 1-BEDROOM UNIT ELECTRICAL PLAN
SCALE: 1/4" = 1'-0"2 TYP. 2-BEDROOM UNIT ELECTRICAL PLAN
SCALE: 1/4" = 1'-0"3 TYP. 3-BEDROOM UNIT ELECTRICAL PLAN
8'4'0"8'4'0"
1 PROVIDE AND INSTALL STRUCTURED MEDIA CENTER PANEL
FLUSH IN WALL FOR UNIT TV AND DATA SERVICES, FIELD
VERIFY LOCATION WITH OWNER PRIOR TO ROUGH-IN. E.C.
SHALL PROVIDE AND INSTALL SERVICE CABLING FROM
PANEL TO UTILITY DEMARC LOCATION. UTILIZE LEVITON OR
EQUAL, REFER TO DETAIL FOR ADDITIONAL INFORMATION.
SCALE: NONEARESIDENTIAL - LEVITON MEDIA CENTER DETAIL
no. description date
For verification; as per 2017
NEC main breaker panels are
not required in each room.
Please verify if desired.
For verification; 2017 NEC
does not require dryer and
range GFCI protection, Idaho
exemptions do not require
GFCI protection.
For verification: As per
Idaho exemption, AFCI
protection required for
bedroom circuits only.
All outlet boxes in walls that are located
in walls joining two separate units shall
be placed in such a manner as to
maintain fire ratings for that specific box.
BLDG.
STEEL
WATER
MAIN
GROUND BAR
AT MAIN TTB
GRND
RODS
STAND-OFF GROUND BAR LOCATED
NEXT TO SERVICE EQUIP.
GROUND BAR SHALL BE
ERICO #EGBA14412CC OR EQUAL.
PROVIDE AND INSTALL ALL REQ'D
LUGS & TERMINALS.
MAIN
SERVICE
EQUIPMENT
G N
NEUTRAL TO GND
BOND AT THIS POINT
ONLY
#3/0 Cu
#4
C
u
CONCRETE ENCASED
ELECTRODE
3/
4
"
C
.
,
1
#
6
C
u
#3
/
0
C
u
#3
/
0
C
u
#2
C
u
BOND
TO FIRE
SPRINKLER
RISER
#3
/
0
C
u
PANEL
'H'
MAIN
FLOOR
2ND FLOOR
METER-PACK
'MP-1'
208Y/120V
3P,4W
800A, MBR
UTILITY TRANSFORMER BY
LOCAL UTILITY CO.
PAD AND VAULT PROVIDED AND
INSTALLED BY ELECT. CONTRACTOR
UNDERGROUND PRIMARY;
CONDUIT AND TRENCHING BY E.C.
CONDUCTORS BY UTILITY CO.
FAULT CURRENT
CALULATIONS WERE
BASED ON
INFINITE BUS, WITH AN
ESTIMATED 300KVA
TRANSFORMER WITH
A 3.21%Z.
REFER TO
DWELLING UNIT
LOAD SCHEDULE
GROUNDING
ELECTRODE
SYSTEM
PANEL
'1B'
PANEL
'1B'
PANEL
'2B'
(A/E3.0)
1-PHASE METER
SECTIONS
*25,972A
<*10kA
M
M
M
M
#13
#14
#15
#16
M
M
M
M
M
M
M
M
M
M
M
M
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
#12
M
M
M
M
#17
#18
#19
#20
M
M
M
M
#21
#22
#23
#24
M
#25
1-PHASE METER
SECTIONS
PANEL
'2B'
PANEL
'1B'
PANEL
'1B'
PANEL
'3B'
PANEL
'2B'
PANEL
'1B'
PANEL
'1B'
PANEL
'2B'
PANEL
'2B'
PANEL
'1B'
PANEL
'1B'
PANEL
'3B'
PANEL
'2B'
3RD FLOOR
PANEL
'1B'
PANEL
'1B'
PANEL
'2B'
PANEL
'2B'
PANEL
'1B'
PANEL
'1B'
PANEL
'3B'
PANEL
'2B'
REFER TO
DWELLING UNIT
LOAD SCHEDULE
REFER TO
DWELLING UNIT
LOAD SCHEDULE
3-PHASE MAIN
SECTION
UNDERGROUND SECONDARY;
CONDUIT AND TRENCHING BY E.C.
CONDUCTORS BY UTILITY CO.
TYP. APARTMENT PANEL AIC RATINGS SHALL BE
AS FOLLOWS:
FEEDER LENGTHS LESS THAN 35FT : 22k AIC
FEEDER LENGTHS GREATER THAN 35FT: 10k AIC
TYP. APARTMENT PANEL AIC RATINGS SHALL BE
AS FOLLOWS:
FEEDER LENGTHS LESS THAN 35FT : 22k AIC
FEEDER LENGTHS GREATER THAN 35FT: 10k AIC
TYP. APARTMENT PANEL AIC RATINGS SHALL BE
AS FOLLOWS:
FEEDER LENGTHS LESS THAN 35FT : 22k AIC
FEEDER LENGTHS GREATER THAN 35FT: 10k AIC
13053
STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP
OFESSIONALENGIN
EE
R
1823 E. Center
Pocatello, Idaho 83201
tel (208) 232-4439
www.payneengineeringinc.com
Engineering Inc.
Consulting Engineers
project:
date:
revisions
Drawings and specifications, as instruments of
professional service are and shall remain the property
of the architect. These documents are not to be used
in whole or in part for any project or purposes
whatsoever, without the prior specific written
authorization of GPC Architects PLLC.
Ownership & Use of Documents
sheet:
18
N
.
M
a
i
n
S
t
.
,
S
t
e
.
2
0
0
Dr
i
g
g
s
,
I
d
a
h
o
8
3
4
2
2
20
8
.
3
5
4
.
8
0
3
6
ww
w
.
g
p
c
a
r
c
h
i
t
e
c
t
s
.
c
o
m
P.E. #:2227
04/18/22
4/
1
5
/
2
0
2
2
1
0
:
2
5
:
2
2
A
M
E3.0
POWER RISER
DIAGRAM &
SCHEDULES
2115
04/18/2022
TE
T
O
N
R
I
V
E
R
L
O
F
T
S
RE
X
B
U
R
G
,
I
D
A
H
O
Dwelling Unit 680700 VA 35.00% 238245 VA TOTAL DEMAND AMPS:710 A
Receptacle 2880 VA 100.00% 2880 VA TOTAL CONN. AMPS:1938 A
Other 500 VA 100.00% 500 VA TOTAL DEMAND VA:256 kW
Lighting 1802 VA 100.00% 1802 VA TOTAL CONN. VA:698 kW
Elec. Heating 13600 VA 100.00% 13600 VA
LOAD TYPE CONN. LOAD % DEMAND EST. DEMAND METER PACK TOTALS
METER PACK LOAD SUMMARY (DEMAND % PER NEC TABLE 220.84)
25 3-BEDROOM 3RD FLOOR 2 125 A 32 kW
24 2-BEDROOM 3RD FLOOR 2 100 A 29 kW
23 2-BEDROOM 3RD FLOOR 2 100 A 29 kW
22 2-BEDROOM 3RD FLOOR 2 100 A 29 kW
21 1-BEDROOM 3RD FLOOR 2 100 A 27 kW
20 1-BEDROOM 3RD FLOOR 2 100 A 27 kW
19 1-BEDROOM 3RD FLOOR 2 100 A 27 kW
18 1-BEDROOM 3RD FLOOR 2 100 A 27 kW
17 3-BEDROOM 2NDD FLOOR 2 125 A 32 kW
16 2-BEDROOM 2ND FLOOR 2 100 A 29 kW
15 2-BEDROOM 2ND FLOOR 2 100 A 29 kW
14 2-BEDROOM 2ND FLOOR 2 100 A 29 kW
13 1-BEDROOM 2ND FLOOR 2 100 A 27 kW
12 1-BEDROOM 2ND FLOOR 2 100 A 27 kW
11 1-BEDROOM 2ND FLOOR 2 100 A 27 kW
10 1-BEDROOM 2ND FLOOR 2 100 A 27 kW
9 3-BEDROOM 1ST FLOOR 2 125 A 32 kW
8 2-BEDROOM 1ST FLOOR 2 100 A 29 kW
7 2-BEDROOM 1ST FLOOR 2 100 A 29 kW
6 2-BEDROOM 1ST FLOOR 2 100 A 29 kW
5 1-BEDROOM 1ST FLOOR 2 100 A 27 kW
4 1-BEDROOM 1ST FLOOR 2 100 A 27 kW
3 1-BEDROOM 1ST FLOOR 2 100 A 27 kW
2 1-BEDROOM 1ST FLOOR 2 100 A 27 kW
1 PANEL H 2 125 A 18 kW
METER
#CIRCUIT DESCRIPTION POLES
BRK
AMPS Load REMARKS
SERVICE ENTRANCE RATED
NOTES:
MFGR/MODEL:Square D/EZ-METER-PAK
ENCLOSURE:Type 3R
AIC RATING:42k MBR RATING:800 A
PHASE/WIRES:3P / 4W RATING:800 A
VOLTAGE:120/208 Wye PANEL TYPE:MBR
METER PACK: METER-PACK MP-1
S = SHUNT-TRIP BREAKER G = GFCI BREAKER R = RED HANDLED, LOCK-OUT TYPE
A = ARC-FAULT BREAKER GP = GFEPD BREAKER LCP = CRKT TO BE ROUTED THROUGH LTG CONTROL PANEL
BRK NOTES:
TOTAL ESTIMATED DEMAND AMPS:88 A
TOTAL AMPS:88 A 89 A
TOTAL LOAD:9.2 kVA 9.2 kVA
23 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 24
21 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 22
19 SPARE -- 20 A 1 0 2250 20
17 SPARE -- 20 A 1 0 2250 2 30 A Water Heater
18
15 FACP 20 A 1 500 1100 1 20 A Elec. Heating EH-1 16
13 SPARE -- 20 A 1 0 2000 1 25 A Elec. Heating EH-2 14
11 SPARE -- 20 A 1 0 2000 1 25 A Elec. Heating EH-2 12
9 SPARE -- 20 A 1 0 2000 1 25 A Elec. Heating EH-2 10
7 Lighting - Exterior 20 A 1 440 2000 1 25 A Elec. Heating EH-2 8
5 Lighting - 3rd Floor 20 A 1 500 720 1 20 A Receptacle 6
3 Lighting - 2nd Floor 20 A 1 400 720 1 20 A Receptacle 4
1 Lighting - 1st Floor 20 A 1 462 1440 1 20 A Receptacle 2
CKT CIRCUIT DESCRIPTION NOTE AMPS P A B P AMPS NOTE CIRCUIT DESCRIPTION CKT
PROVIDE WITH LOCKABLE DOOR
NOTES:
MFG & MODEL:SQ. D/NQ SERIES DIMENSIONS:20"W x 5.8"D x *"H FEED:BOTTOM
ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A
MOUNTING:FLUSH WIRES:3 PANEL AMPS:125 A
FED FROM:METER-PACK MP-1 PHASES:1 PANEL TYPE:MLO TETON RIVER LOFTS
LOCATION: VOLTAGE:120/208 Single A.I.C. RATING:10k PROJECT:
PANEL: H
PAYNE ENGINEERING
SCALE: NONEABLDG GROUNDING ELECTRODE SYSTEM DETAIL
SCALE: NONE1POWER RISER DIAGRAM
POWER RISER FEEDER SCHEDULE
SOURCE LOAD
# OF CONDUIT
RUNS
CONDUIT
SIZE FEEDER SIZE
CONDUCTOR
TYPE
LOAD
AMPS
FEEDER
BREAKER SIZE
METER-PACK
MP-1
PANEL H 1 1 1/2" 2-#1, 1-#1, 1-#6 COPPER 88 A 125 A
FEEDER SCHEDULE LEGEND & NOTES
QTY & SIZE
OF PHASE
CONDUCTOR(S)
QTY-#PHASE SIZE, QTY-#NEUTRAL SIZE, QTY-#GROUND SIZE
QTY & SIZE
OF NEUTRAL
CONDUCTOR(S)
QTY & SIZE
OF GROUND
CONDUCTOR(S)
1. # OF RUNS INDICATES THE NUMBER OF PARALLEL RUNS FOR THE FEEDER.
2. FEEDER SIZE IN SCHEDULE IS AS INDICATED BELOW:
no. description date
For verification: Wire sizes
exceed code requirements in
250.66. Will inspect as per
these requirements if desired.