Loading...
HomeMy WebLinkAboutFS PLANS -22-00263 - 7N Apartments - Bldg 4 - 4 PlexW/D W/D RISER ROOM BED 1 CL. BATH 1 BATH 2 KITCHEN DINING FAMILY RM. BED 2 BED 3 KITCHEN DINING BED 1 BATH 1 BATH 2 BED 2BED3 FAMILY RM. NO A/S NO A/S NO A/S NO A/S NO A/S NO A/S MECH MECH PANTRYNOA/S PANTRYNOA/S CL. NO A/S CL. NO A/S STOR STOR CL. NO A/S CL. NO A/S W/D W/D BED 1 CL. BATH 1 BATH 2 KITCHENDINING FAMILY RM. BED 2 BED 3 KITCHEN DINING BED 1 BATH 1 BATH 2 BED 2BED3 FAMILY RM. NO A/S NO A/S NO A/S NO A/S NO A/S NO A/S MECH MECH PANTRYNOA/S PANTRYNOA/S CL. NO A/S CL. NO A/S STOR STOR CL. NO A/S CL. NO A/S A.H.J. A.F.F. F.O.W. T.O.B. B.O.B. C.L. B.L. RN RU DN DD SSP SSU HSW E/C A.S. FLG GRV THD TYP. F.D.C. N.S.T. E.L. AUTHORITY HAVING JURISDICTION ABOVE FINISH FLOOR FACE OF WALL TOP OF BEAM BOTTOM OF BEAM CENTERLINE BRANCHLINE RISER NIPPLE RISE UP DROP NIPPLE DROP DOWN STANDARD SPRAY PENDANT STANDARD SPRAY UPRIGHT HORIZONTAL SIDE WALL EXTENDED COVERAGE AUTOMATIC SPRINKLERS FLANGE GROOVE THREADED TYPICAL FIRE DEPARTMENT CONNECTION NATIONAL STANDARD THREAD ELEVATION N.P.T.NATIONAL PIPE THREAD I.T.V.INSPECTOR'S TEST VALVE C.I.CAST IRON D.I.P.DUCTILE IRON PIPE G.P.M.GALLONS PER MINUTE P.S.I.POUNDS PER SQUARE INCH ABBREVIATIONS NOM.NOMINAL M.R.A.MOST REMOTE AREA U.G.UNDERGROUND 3/4"(5 FT.) PIPE SIZE /DIST.BETWEEN HANGER 2-HOLE STANDOFF HANGER ONE HOLE WRAPAROUND HANGER DOUBLE OFFSET HANGER SIDE MOUNT STRAP HANGER 1"(6 FT)1 1/4"(6 1/2 FT)1 1/2"(7FT)2"(8 FT) PIPING NOTES /SYMBOL LEGEND HYDRAULIC CALCULATION NODE EXISTING FIRE SPRINKLER PIPING NEW FIRE SPRINKLER PIPING 1.ALL PIPING SHALL BE C.P.V.C.LISTED FOR USE IN FIRE SPRINKLER SYSTEMS. 2.ALL FITTINGS SHALL BE C.P.V.C.LISTED FOR USE IN FIRE SPRINKLER SYSTEMS. 3.ALL PIPE LENGTHS ARE CENTER TO CENTER U.N.O. 4.CUTTING OIL USED IN MIXED STEEL/CPVC SYSTEMS SHALL BE COMPATIBLE FOR USE W/CPVC. 5.STEEL PIPING,WHERE INDICATED,SHALL BE BULLMOOSE EDDYTHREAD 40 (THREADED), BULLMOOSE EDDYFLOW (GROOVED)W/CAST/DUCTILE IRON FITTINGS. NO AUTOMATIC SPRINKLERS THIS AREANOA/S HANGER LOCATION HYDRAULIC CALCULATIONS DESIGN AREA: LOCATION: NO.SPRINKLERS CALCULATED: MAX SPRINKLER SPACING: SYSTEM DEMAND @ SOURCE GPM @ PSI OCCUPANCY: 2 LOWER BED 2 13R 1 400 SQ.FT. 20.0 35.9 AVAILABLE WATER SUPPLY: DENSITY:.05 GPM /SQ.FT. GPM @ PSI20.0 75.5 SYSTEM DEMAND @ B.O.R. GPM @ PSI20.0 32.5 GENERAL FIRE PROTECTION NOTES: 1.FIRE SPRINKLER DESIGN AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH NFPA #13R 2019 ED.,THE LOCAL A.H.J.AND THE IDAHO STATE FIRE MARSHALL'S REQUIREMENTS. 2.ALL NEW MATERIAL SHALL BE U.L.LISTED AND FM APPROVED FOR USE IN FIRE SPRINKLER SYSTEMS. 3.ALL NEW HANGERS SHALL BE INSTALLED PER NFPA STANDARDS AND THE MANUFACTURER'S SPECIFICATIONS. 4.DESIGN CRITERIA:SEE HYDRAULIC DATA PLATES. 5.FIRE SPRINKLER SYSTEM SHALL BE HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS AND WITNESSED BY THE A.H.J. 6.A FINAL SYSTEM INSPECTION IS REQUIRED BY THE A.H.J. 7.APPROVED PLANS SHALL REMAIN ON JOB SITE AT ALL TIMES. 8.ALL UNDERGROUND PIPING,ELECTRICAL WIRING AND INSULATING IS BY OTHERS. 9.PRIOR TO SYSTEM CONNECTION VERIFY THAT THE UNDERGROUND FIRE LINE HAS BEEN PROPERLY TESTED AND FLUSHED IN ACCORDANCE WITH NFPA #24. 67 6 C A R L O W N.I.C.E.T. CERTIFICATION CERTIFICATION NO:106219 BRIAN A .GUSTKE FIRE SPRINKLER SYSTEM LAYOUT VA LID THRU 09-01-2023 LEVEL III REVISIONS JOB NO: DATE: ### 6-2-22 1 3 2 PO B O X 6 3 7 AM E R I C A N F A L L S , I D 8 3 2 1 1 LI C E N S E : F P S C # 1 1 6 (2 0 8 ) 5 4 8 - 2 3 1 0 FP-1 ONE OF ONE FIRE SPRIN KLER PLAN 4P L E X RE X B U R G , I D A H O DESIGN AREA #1 4 SPRINKLERS HYDRAULIC CALCULATIONS DESIGN AREA: LOCATION: NO.SPRINKLERS CALCULATED: MAX SPRINKLER SPACING: SYSTEM DEMAND @ SOURCE GPM @ PSI OCCUPANCY: 1 2ND FLOOR 13R 4 256 SQ.FT. 75.1 57.4 AVAILABLE WATER SUPPLY: DENSITY:.05 GPM /SQ.FT. GPM @ PSI75.1 69.3 SYSTEM DEMAND @ B.O.R. GPM @ PSI75.1 47.9 SPRINKLER COUNTS DO NOT INCLUDE SPARE SPRINKLERS FOR HEAD CABINET QTY MANUF.MODEL TYPE RESPONSE SIN #N.P.T.FINISH TEMP. SPRINKLERS SYMBOL TYPEQTY FINISH ESCUTCHEONS TEMP TOTAL:53 K-FACTOR UPRIGHT SPRINKLER ON 1"SPRIG UP F1RES4925CHRMRELIABLE PENDENT RES R3516 1/2"175°F SEMI-REC WHITE25 ---4.9 F1RES4424CHRMRELIABLE HSW RES R3531 1/2"175°F ---4.4 SPRINKLER COUNTS DO NOT INCLUDE SPARE SPRINKLERS FOR HEAD CABINET SEMI-REC WHITE24 INDIVIDUAL BUILDING SPRINKLER COUNTS TOTAL PROJECT SPRINKLER COUNTS 12 NORTH 0FIRESPRINKLERPLAN SCALE:1/4"=1'-0" 4 8UPPERLEVEL NORTH 0FIRESPRINKLERPLAN SCALE:1/4"=1'-0" 4 8 12MAINLEVEL DESIGN AREA #2 1 SPRINKLER &N.F.P.A.#25 WRENCH, SPRINKLER SPARE HEADS, HEAD BOX W/ ELECTRIC BELL (OUTSIDE) 6"120V U.G.PIPING RISER DETAIL SCALE:NONE 1 1 / 4 " 2" 1 1/4"AMES 2000B OR = DOUBLE CHECK VALVE 1 1 / 4 " R I S E R A S S E M B L Y 1 1/4"FLOW SWITCH 1 1 / 4 " 1 1/4"TO SYSTEM RELIEF VALVE) (W/PRESSURE 1"DRAIN /I.T.V. 1 1/4" 1 1 / 4 " 1 1/4"CONTROL VALVE TO HOSE CONNECTION FOR FORWARD FLOW TESTING OF BACKFLOW PREVENTOR PENDENT SPRINKLERS SHALL BE LOCATED A MINIMUM OF 3 FT FROM CEILING MOUNTED OBSTRUCTIONS OR AN ADDITIONAL SPRINKLER SHALL BE ADDED ON THE OPPOSITE SIDE OF THE OBSTRUCTION. *EXCEPTION:IN ALL COMPARTMENTS THAT ARE 400 CU.FT.OR LESS A SINGLE SPRINKLER AT THE HIGHEST ELEVATION SHALL BE SUFFICIENT WITHOUT REGARD TO OBSTRUCTIONS OR MINIMUM DISTANCES TO WALLS.(REF:NFPA 13D:8.2.5.1) ORIFICE STATIC PSI PITOT P.S.I. RESIDUAL P.S.I. LOCATION BY WHO DATE G.P.M. ORIFICE STATIC PSI PITOT P.S.I. RESIDUAL P.S.I. LOCATION BY WHO DATE G.P.M. FLOW TEST INFORMATION 84 50 17 2.5" 692 5-4-22 JOB SITE ROCK CREEK FIRE PROTECTION 75.6 41.6 ACTUAL USED-10%= BRACE PIPE TOLCO FIG 980UNIVERSALSWAY BRACE ATTACHMENT 1"SCH40 TOLCO FIG 4A SWAY BRACE /FIG.3000 F3RES444CHRMRELIABLE DRY HSW RES RA5231 1"175°F ---4.4 SEMI-REC WHITE4 SPRINKLER COUNTS DO NOT INCLUDE SPARE SPRINKLERS FOR HEAD CABINET QTY MANUF.MODEL TYPE RESPONSE SIN #N.P.T.FINISH TEMP. SPRINKLERS SYMBOL TYPEQTY FINISH ESCUTCHEONS TEMP TOTAL:212 K-FACTOR UPRIGHT SPRINKLER ON 1"SPRIG UP F1RES49100CHRMRELIABLE PENDENT RES R3516 1/2"175°F SEMI-REC WHITE100 ---4.9 F1RES4496CHRMRELIABLE HSW RES R3531 1/2"175°F ---4.4 SPRINKLER COUNTS DO NOT INCLUDE SPARE SPRINKLERS FOR HEAD CABINET SEMI-REC WHITE96 F3RES4416CHRMRELIABLE DRY HSW RES RA5231 1"175°F ---4.4 SEMI-REC WHITE16 PATIO PATIO KITCHEN FAMILY RM.PATIO KITCHEN FAMILY RM.PATIO SECTION 'A' SCALE:3/16"=1'-0" INSULATION OVER FIRE SPRINKLER PIPING TYP. WOOD TRUSSES @ 24"O/C TYP. WOOD JOISTS @ 16"O/C @ LOWER LEVEL NEW HSW SPRINKLER TYP. NEW PENDENT SPRINKLER TYP. 11 ' - 6 " 4'-1012 "5'-21 2"3'-912" 4'-612"15'-4"4'-11 2" 5' - 4 1 2" 13 ' - 4 12" 4' - 1 1 2" 4'-712" 3'-61 2" 7'-012" 11 ' - 8 " 4' - 5 " 3' - 1 0 1 2" 4' - 5 " **D IMENSIONS TYPICAL FOR O THER HALF OF BUILDING **D IMENSIONS TYPICAL FOR O THER HALF OF BUILDING 9' - 0 " 7'-912 " 9' - 0 " 5'-9" 4'-612 "15'-4"4'-11 2" 8'-0" 5' - 0 1 2" 9' - 1 12" 3' - 3 1 2" 5' - 2 " 3' - 1 1 2" 7'-61 2" 1'-5" 10 ' - 0 " 10'-0" 4' - 4 1 2" D ESIGN ARE A #3 4 SPRINKLERS N ORTH SITE PLAN SCALE:1"=30 FT. **SITE PLAN IS FOR HYDRAULIC REFERENCE ONLY. R EFER TO CIVIL DRAWIN GS FOR INSTALLATION DETAILS &OTH ER INFO NOT SH OWN ON THIS PLAN BLDG #1 BLDG #2 BLDG #3 BLDG #4 KEY NOTES: 1 2 1 1 112 2 22 HYDRAULIC CALCULATI ONS DESIGN AREA: LOCAT ION: NO.SPRINKLERS CALCULATED: MAX SPRINKLER SPACING: SYSTEM DEMAND @ SOURCE GPM @ PSI OCCUPANCY: 3 MAIN FLOOR 13R 4 256 SQ.FT. 52.6 36.0 AVAILABLE WAT ER SUPPLY: DENSITY:.05 GPM /SQ.FT. GPM @ PSI52.6 75.3 SYSTEM DEMAN D @ B.O.R. GPM @ PSI52.6 29.2 CL. CL. PIPING AT FIRST FLOOR (FOR REFERENCE) **ALL CEILINGS AR E 9'-3"A.F .F.THIS LEVEL **ALL CEILINGS AR E 8'-0"A.F .F.THIS LEVEL IDAHO STATE FIRE MARSHAL'S OFFICE FIRE SPRINKLER PLAN REVIEW ACCEPTED 07/14/2022