Loading...
HomeMy WebLinkAboutREDLINED PLANS - 21-01027 - 1139 Greenside Loop - New SFRAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Description : 1139 Greenside Loop - New SFR Address : 1139 Greenside Loop Application Type : Document Filename : Plan 12-29-21.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 2 Free text Larry Beesley : Building Open 2 Street Number Displayed on House Pg 2 Free text Larry Beesley : Building Open 2 Minimum Frost Depth Ground Surface to Bottom of Footing 36" Pg 2 Free text Larry Beesley : Building Open 2 Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. Pg 3 Free text Larry Beesley : Building Open 3 Roof Ventilation as per R806 Pg 3 Free text Larry Beesley : Building Open 3 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Pg 4 Free text Larry Beesley : Building Open 4 Garage needs engineering Pg 5 Free text Larry Beesley : Building Open 5 SD CO Pg 5 Free text Larry Beesley : Building Open 5 SD CO Pg 5 Free text Larry Beesley : Building Open 5 SD CO Pg 5 Free text Larry Beesley : Building Open 5 TEMP. Pg 5 Free text Larry Beesley : Building Open 5 TEMP. # 21-01027 New Single Family Residence Report Date: 01.25.2022 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 5 Free text Larry Beesley : Building Open 5 FAN Pg 5 Free text Larry Beesley : Building Open 5 FAN Pg 5 Free text Larry Beesley : Building Open 5 FAN Pg 5 Free text Larry Beesley : Building Open 5 FAN Pg 5 Free text Larry Beesley : Building Open 5 FAN Pg 5 Free text Larry Beesley : Building Open 5 Attic Access 22"x30" minimum access where attic clear height exceeds 30" (R807) Pg 6 Free text Larry Beesley : Building Open 6 Design Requirements: Minimum Roof Live Load 35# per sq. ft., Minimum Wind 85 MPH, Seismic Zone D1 Pg 6 Free text Larry Beesley : Building Open 6 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" Pg 7 Free text Larry Beesley : Building Open 7 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) Pg 8 Free text Larry Beesley : Building Open 8 Pine Brook Estates Pg 8 Free text Kyle Baldwin : P&Z Open 8 Please show street location, street name and sidewalk location in Site plan Report Date: 01.25.2022 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) ION T A B L E EVI S E D B Y D E S C R I P T I O N DATE: 12/28/2021 General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by River Bend Drafting and Design. Pg 1 GENERAL NOTES THE FOLLOWING INFORMATION ARE FOR CODE COMPLIANCE. ANY LOCAL CODES, SPECIFICATION BY AN ENGINEER OR ARCHITECT SUPERSEDE THIS INFORMATION. 1 HEATING AND COOLING EQUIPMENT AND APPLIANCES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURE'S INSTALLATION INSTRUCTIONS AND THE REQUIREMENTS IN THE 2018 IRC CHAPTER 14. 2 CLOTHES DRYER TO BE EXHAUSTED IN ACCORDANCE WITH MANUFACTURE'S INSTRUCTIONS. EXHAUST DUCTS SHALL TERMINATE ON THE OUTSIDE OF THE BUILDING. EXHAUST DUCT LENGTH AND INSTALLATION TO MEET THE REQUIREMENTS IN 2018 IRC SECTION M1502. 3 DWELLING UNIT BEDROOMS FOR ALL 125- VOLT BRANCH CIRCUITS FOR 15 & 20 AMP RECEPTACLE OUTLETS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER. 4 A 22 " X 30" ATTIC SPACE ACCESS POINT IS REQ'D. IF THE PLANS DO NOT SPECIFY A LOCATION, THE CONTRACTOR IS TO LOCATE IT. (2018 IRC R807.1) 5 A 18" X 24" CRAWLSPACE ACCESS POINT IS REQ'D IF A CRAWLSPACE EXISTS. IF THE PLANS DO NOT SPECIFY A LOCATION THE CONTRACTOR IS TO LOCATE IT. (REFERENCE 2018 IRC, R408.4) 6 BUILDINGS WITH A CRAWL SPACE SHALL HAVE FOUNDATION VENTS THAT COMPLY WITH SECTION R408 OF THE 2018 IRC 7 PROVIDE FLOOR AND/ OR LANDING ON EACH SIDE OF EXTERIOR DOORS. THE WIDTH OF THE LANDING SHALL NOT BE LESS THAN THE WIDTH OF THE STAIRWAY OR DOOR SERVED. MINIMUM OF 36" IN THE DIRECTION OF TRAVEL IS REQUIRED. A STEP OF 7 3/4" IS ALLOWED AT NON- EGRESS EXTERIOR DOORS PROVIDED THE DOOR DOES NOT SWING OVER THE STEP. (REFERENCE 2018 IRC R311.3) 8 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL AT A MINIMUM OF 6" WITHIN THE FIRST 10 FEET (R401.3) 9 BACKFILL SHALL NOT BE PLACED AGAINST THE WALL UNTIL THE WALL HAS SUFFICIENT STRENGTH AND HAS BEEN ANCHORED TO THE FLOOR ABOVE, OR HAS BEEN SUFFICIENTLY BRACED TO PREVENT DAMAGE BY THE BACKFILL. (2018 IRC R404.1.7) 10 FLASHING SHALL BE INSTALLED IN SUCH A MANNER THAT PREVENTS MOISTURE FROM ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE PERMEABLE MATERIALS, AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. (R903.2) 11 AN ICE BARRIER CONSISTING OF AT LEAST TWO LAYERS UNDERLAYMENT CEMENTED TOGETHER OR OF A SELF-ADHERING POLYMER MODIFIED BITUMEN SHEET, SHALL BE USED IN LIEU OF NORMAL UNDERLAYMENT AND EXTEND FROM THE EAVE'S EDGE TO A POINT AT LEAST 24" INSIDE THE EXTERIOR WALL LINE OF THE BUILDING. (R905.2.7.1) 12 THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN 1/2" GYPSUM BOARD APPLIED TO THE GARAGE SIDE. HABITABLE ROOMS ABOVE THE GARAGE SHALL HAVE A MIN. OF 5/8" TYPE X GYPSUM BOARD. (REFERENCE IRC R302.6) MINIMUM INSULATION R-VALUE (CLIMATE ZONE 6) CEILING R-49 WALLS R-20+5/13+10 FLOORS R-30 BASEMENT R-15/20 (SEE 2018 IRC TABLE N1102.1.1) MINIMUM SIZE OF CONCRETE FOOTINGS LOAD BEARING VALUE OF SOIL = 2000 PSF FOUNDATION WALL FOOTING WIDTH HEIGHT DEPTH WIDTH REINF. 6" OR 8" 4'-0" 8 16" (2) #4 8" 8'-0 10" 20" (3) #4 TYPICAL INTERIOR WALL REFERENCE IRC-2018 SECTION R601-R610. 2X4 STUDS FRAMED @ 16" O.C. WITH (2) 2X4 TOP PLATES WITH (1) 2X4 BOT. PLATE WITH 1/2" DRYWALL BOTH SIDES TAPED AND PREPPED FOR INTERIOR FINISHES POST AN 1 FOUND 12" DIA C CONCRE (CONTR TO CON 2 EXTER A 2X10 B 2X10 C 2X10 CO D 2X T (SE E DEC COD 3 ROOF SYSTEM: A RAFTERS OVER BEAM B 4X4 POST WITH SIMPSON POST CAP & POST STIRRUP (OR EQUAL) CONTRACTOR TO VERIFY WITH OWNER PRIOR TO CONSTRUCTION LOCATION OF ALL DECK LOCATIONS, IF ANY. CONTRACTOR TO PROVIDE DETAILS ON ALL ASPECTS OF ANY INCLUDED DECK SYSTEM, AND LOCATION OF REQUIRED BEARING SYSTEM. ABOVE IS PROVIDED AS "TYPICAL" CONSTRUCTION CLOSURES THAT DO NOT ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER. 6 TRIANGLE OPENING FORMED BY THE RAISER, TREAD AND BOTTOM RAIL SHALL BE SUCH THAT A SPHERE 6" DIAMETER CANNOT PASS THROUGH. 7 GUARD RAIL SHALL NOT BE CONSTRUCTED WITH HORIZONTAL RAILS OR OTHER ORNAMENTAL PATTERN THAT RESULTS IN A LADDER EFFECT. 8 HANDRAILS SHALL HAVE A CIRCULAR CROSS SECTION OF 1 1/4" MIN. - 2 " MAX. OR EQUIVALENT. 9 IF HANDRAIL IS NOT CIRCULAR, SEE SECTION R311.7.8.3 FOR GRIP SIZE OPTIONS. (REFERENCE 2018 IRC R311 & R312) 1 ALL ELECT 2 ALL FIXTUR 3 METER BA ELECTRICA 4 MAIN PANE DETERMIN THESE DRAWINGS ARE THE PROPRIETARY WORK PRODUCT AND PROPERTY OF RIVER BEND DRAFTING AND DESIGN,DEVELOPED FOR THE EXCLUSIVE USE OF DEBRA CUMMINS. USE OF THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF RIVER BEND OR DEBRA CUMMINS IS PROHIBITED AND MAY SUBJECT YOU TO A CLAIM FOR DAMAGES. THESE DRAWINGS AND SPECIFICATIONS CONSTITUTE A BUILDER'S SET. THEY ARE NOT COMPLETE IN DETAIL AND WILL REQUIRE COORDINATION BY OWNER AND CONTRACTOR TO ADDRESS CONSTRUCTION ISSUES AND DECISIONS PENDING AT ISSUANCE OF DRAWINGS. Highest Ridge FRONT ELEVATION BACK ELEVATION RE V I S I O N T A B L E NU M B E R D A T E R E V I S E D B Y D E S C R I P T I O N DR A W I N G S P R O V I D E D B Y : DATE: Ri v e r B e n d D r a f t i n g a n d D e s i g n El i s e S h u r t l i f f 2 0 8 - 5 5 7 - 3 6 2 1 El i s e @ r i v e r b e n d h o u s e p l a n s . c o m Elevations 7:12 Pitch Main, Front and sides 9' Main Walls 9' Basement Walls Garage to match TYP 12/28/2021 General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by River Bend Drafting and Design. Pg 2 Pl a ns For: TW E B B C O N S T R U C T I O N Street Number Displayed on House Minimum Frost Depth Ground Surface to Bottom of Footing 36" Ground Surface to Slope away from Foundation a minimum of 6" within first 10 ft. LEFT ELEVATION LEFT ELEVATION RE V I S I O N T A B L E NU M B E R D A T E R E V I S E D B Y D E S C R I P T I O N DR A W I N G S P R O V I D E D B Y : DATE: Ri v e r B e n d D r a f t i n g a n d D e s i g n El i s e S h u r t l i f f 2 0 8 - 5 5 7 - 3 6 2 1 El i s e @ r i v e r b e n d h o u s e p l a n s . c o m Elevations cont.12/28/2021 Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by River Bend Drafting and Design. Pg 3 Pl a ns For: 7:12 Pitch Main, Front and sides 9' Main walls 9' Basement foundation walls Garage to match TYP TW E B B C O N S T R U C T I O N Roof Ventilation as per R806 Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) S S S S S S S S E8E8 Elevation 8 12'10'-4" 7' - 4 " 12 ' 7' - 6 " 6' - 9 " 6' - 9 " 13 ' - 2 1 / 4 " 12 ' - 0 1 / 4 " 5' - 3 1 / 2 " 2' 26 ' - 1 0 " 13 ' - 6 " 72'-10" 3'3'-6" 6'-6"41'-5"11'-4"12'-4" 71'-7" 3'-6 1/4" 8' 18 ' - 3 " 17 ' - 9 " 72 ' - 1 0 " 51'-1"7'-3 1/4"3'-3 3/4" 61'-8" 8' 6'-4 1/4"7'-1" 10'-4"12'13'-6"10'-7" 41 ' - 0 " X 5 8 ' - 7 " GA R A G E RE V I S I O N T A B L E NU M B E R D A T E R E V I S E D B Y D E S C R I P T I O N DR A W I N G S P R O V I D E D B Y : DATE: Ri v e r B e n d D r a f t i n g a n d D e s i g n El i s e S h u r t l i f f 2 0 8 - 5 5 7 - 3 6 2 1 El i s e @ r i v e r b e n d h o u s e p l a n s . c o m Foundation Plan 12/28/2021 Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by River Bend Drafting and Design. pg 4 Pl a ns For: 7:12 Pitch Main, Front and sides 9' Main Walls 4' Crawlspace Garage to match TYP TW E B B C O N S T R U C T I O N Main Floor 2753 s/f Garage 1536 s/f Total 4289 s/f Garage needs engineering 3020FX 3020FX 2020RS 2020RS 2020RS 30 5 0 S C 30 5 0 S C 5050RS5050RS30684040RS 90 8 0 3068 90 8 0 90 8 0 30 5 0 S C 30 5 0 S C 36 8 0 30 6 8 28 6 8 6068 35 6 8 2668 506830683068 2668 5068 2668 3050SC 3050SC 30 5 0 S C 30 5 0 S C 50 6 8 28 6 8 26 6 8 UP 4" 3' - 4 " 5' - 7 " 4'5'-5 1/2" 7' 3' - 4 " 4' - 1 1 " 4' - 1 1 " 8' 20 ' - 7 " 12 ' - 3 " 9' - 8 1 / 4 " 17' - 3 1 / 2 " 5'-5"2'-4"2'-4"5'-3"3'-4 1/2"3'-9" 21 ' - 4 " 3' - 6 " 5'-1" 6'-10" " 3'-8" 2'-1" 3' - 5 1 / 1 6 " 3' - 4 " 6' - 3 1 / 2 " 5' - 1 " 3' - 4 " 4" 4'-11"2'-4"2'-4"4'-11"3'-5" 7'-4 4' - 1 9 / 1 6 " 4' - 5 " 3' - 4 " 4' - 5 1 / 2 " 7' - 4 " 12 ' 7' - 6 " 6' - 9 " 6' - 9 " 2' 26 ' - 1 0 " 13 ' - 6 " 72 ' - 1 0 " 4' - 1 1 " 3' - 4 " 4' - 1 1 " 13 ' - 2 " 2 1 / 1 6 " 4' - 3 1 / 2 " 3' - 9 " 3' - 4 " 3' - 8 " 8' - 7 " 10 ' - 9 " 15'-4"7'-1 1/2"5'-4 1/2"9'-5 1/2"2'-4 1/2"12'-1" 71'-7" 3'-4"3'-4"3'-4" 6'-6"10'7'-1" 3'3'-6"24'-1"10'-10"6'-4"5'-10"5'-10"6'6'-2" 6'-6"41'-3"11'-8"12'-2" 71'-7" 3'-9" 11 ' - 3 1 5 / 1 6 " 2' - 5 " 17 ' - 3 9 / 1 6 " 2' 2 1 / 1 6 " 3' 2'-6" 16 ' - 9 " X 1 4 ' - 10 ' - 2 " X 1 3 ' - 7 " 12 ' - 2 " X 1 1 ' - 7 " 12 ' - 2 " X 1 1 ' - 7 " 10 ' - 6 " X 1 1 ' - 4 " 41 ' - 8 " X 3 1 ' - 3 " GA R A G E BE D R O O M MA S T E R B D Fl o o d L i g h t Fl o o d L i g h t So f f i t C a n So f f i t C a n So f f i t C a n Al l S o f i t t s 1 8 " m i n OF F I C E BE D R O O M BE D R O O M CR A W L S P A C E A C C E S S RE V I S I O N T A B L E DA T E R E V I S E D B Y D E S C R I P T I O N DR A W I N G S P R O V I D E D DATE: Ri v e r B e n d El i s e S h u r t El i s e @ r i v e r p Main Floor 12/28/2021 Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by River Bend Drafting and Design. H1 - STHD 14 H2 - RJSTHD 14 Pg 5 7:12 Pitch Main, Front and sides 9' Main Walls 4' Crawlspace Garage to match TYP Main Floor 2753 s/f Garage 1536 s/f Total 4289 s/f (2 ) 2 x 1 0 f o r p o r t a l f r a m i n g re f e r t o p a g e 6 f i g u r e 1 H1 H1 (2 ) 2 x 1 0 f o r p o r t a l f r a m i n g re f e r t o p a g e 6 f i g u r e 1 H1 H1 (2 ) 2 x 1 0 f o r p o r t a l f r a m i n g re f e r t o p a g e 6 f i g u r e 1 H1 H1 10 C F M F r e s h A i r Sm o k e D e t e c t o r 10 C F M F r e s h A i r Sm o k e D e t e c t o r 10 C F M F r e s h A i r Sm o k e D e t e c t o r 10 C F M F r e s h A i r Sm o k e D e t e c t o r SD CO SD CO SD CO TEMP. TEMP. FAN FAN FAN FAN FAN Attic Access 22"x30" minimum access where attic clear height exceeds 30" (R807) Elevation 8 RE V I S I O N T A B L E NU M B E R D A T E R E V I S E D B Y D E S C R I P T I O N Roof System: 2018 IRC Code Architectural Grade, 25 year Asphalt Shingles over #15 building felt over 7/16" Ext. OSB roof sheeting w/Clips & nailed 6" O.C.-Edges, 10" O.C.-field over 6:12 Pitch Engineered Trusses @ 24" O.C. (Framed According to Engineered Truss Layout) with R-49 Blown in Attic Insulation with 5/8" Sheet Rock on Interior Side Taped Prep'd for Interior Finishes Contractor to indicate 22"x30" Attic Access Location 2018 IRC Ice Protection Ice Barrier consisting of 2 layers of cemented under-layment and extend from the eave's edge 24" min. from inside exterior wall DR A W I N G S P R O V I D E D B Y : Stair System: 2018 IRC R106, R302.7, 311.7.2, R311.7.5, R311.7.8 Eq Stair risers 7 3/3" Max height Eq Stair treads 10" Min depth over (3) 11.5" MIN Stair Stringers securely mounted to framing with Cont. Handrail System mounted 36" above stair plane with Handrail return to wall with a min 6'-8" Head clearance above stair plane with all other Railing system to be a min 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 1/2" gypsum board under stairs DATE: Ri v e r B e n d D r a f t i n g a n d D e s i g n El i s e S h u r t l i f f 2 0 8 - 5 5 7 - 3 6 2 1 El i s e @ r i v e r b e n d h o u s e p l a n s . c o m 12/28/2021 A Soffit System: 2018 IRC code 2x6 Facia Board with style "D" Metal Drip Edge with 3/8" soffit Sheeting with 3" Continuous Soffit Venting with add'l 2x4 support as required B Exterior Walls: 2018 IRC code R602.10.1 A braced wall panel shall begin within 10 ft from each end of a braced wall line. The distance between adjacent edges of braced wal panels along a braced wall line shall not be greater than 20 ft. 2018 IRC code R106.1 Vinyl Siding and Brick over Weather Resistive Barrier 7/16" APA OSB & Nailing Pattern 6" - edge 12" - field 2x6 Stud framed @24" O.C. UNO with (2) 2x6 Top Plates with (1) 2x6 Bottom Plate with min R-21 Bottom Insulation with 1/2" Sheetrock Inside Occupancy separation between house, attic, and garage 2018 IRC, Section R106 and R308.4.5 Taped Prep'd for Interior finishes C Interior Walls: 2018 IRC COde 2x4 Stud framed @ 24" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides Taped Prep'd For Interior Finishes D Floor System: 2018 IRC Code 3/4" T&G Sub-floor Glued and Nailed over 11-7/8 TJI Engineered Floor Joist Series, Placement, and O.C Spacing as determined & indicated on TJXpert Layout (Version 6.0 or later) connected to Rim Joist, spliced using gal. metal ties not less than .058" x 1.5" wide fastened w/6 16d nails ea. side over 1/2" Sheetrock on Ceiling side Taped and Prep'd for Interior finishes E Basement Furring: 2x4 Stud Framed @24" O.C. with Baring Walls @ 16" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with R-13 Batt Insulation with 6-Mill Poly Vapor Barrier with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes F Foundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 1/2" Anchor Bolts @72" O.C. 10" Long, 7" Embedded Max 12" from all Corners or Splices Concrete wall 8' and under (1) Horizontal Rebar in top 12" and one at mid height 8'1" TO 9'6" (1) Horizontal Rebar in top 12" and one bar at each third point Min (2) Anchor Bolts per Sill Plate w/nut & ROUND Plate Washer 2 1/20 x 1/4" Min. for each Bolt over Concrete Foundation Wall Consistent w/2015 IRC R401-403 with Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/2018 IRC Section R106.1 over Undisturbed Soil G Window Well System: 2018 IRC Code Min. egress window opening will be 5.7 sq ft 7 Sill height no higher than 44" above FFL Window Wells provide a net clear of 9 sq ft w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps Ladder or Steps 12"- width Inside, 3" from walls, Spaced no more than 18" O.C JCross Section Smoke Alarms 2018 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms Carbon Monoxide Alarms 2018 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Fastners for Preservative treated wood Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasterners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Ventilation 2018 IRC, Section R408.1, R408.2, and R408.3 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 300 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by River Bend Drafting and Design. Figure R602.10.6.2 Alternate Braced Wall Panel Garage Portal Design Figure 1 Pg 6 Exhaust and Ventilation Whole house Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Table R403.1 Min Width of Conc. or Masonry Footings (inches) Load Baring Value of soil 1500 2000 3000 Conventional Light frame Construction 1-story 12 12 12 2 story 15 12 12 3-story 23 17 12 4" Brick Veneer over light frame 1-story 12 12 12 2-story 21 16 12 3-storu 32 24 16 Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72"max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 18" is equal to #5 @ 25" or #6 @ 36" Frost Protection 403.1.4.1 Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the frost line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: - Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required - Decks not supported by a dwelling need not be provided with footings that extend below the frost line - Footings shall not bear on frozen soil unless the frozen condition is permanent Pl a ns For: TW E B B C O N S T R U C T I O N Design Requirements: Minimum Roof Live Load 35# per sq. ft., Minimum Wind 85 MPH, Seismic Zone D1 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" 7 : 12 7 : 1 2 7 : 1 2 7 : 12 7 : 1 2 7 : 1 2 7 : 1 2 7 : 12 7 : 1 2 7 : 1 2 7 : 1 2 7 : 12 7 : 1 2 7 : 1 2 7 : 1 2 RE V I S I O N T A B L E NU M B E R D A T E R E V I S E D B Y D E S C R I P T I O N DR A W I N G S P R O V I D E D B Y : DATE: Ri v e r B e n d D r a f t i n g a n d D e s i g n El i s e S h u r t l i f f 2 0 8 - 5 5 7 - 3 6 2 1 El i s e @ r i v e r b e n d h o u s e p l a n s . c o m 12/28/2021 General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by River Bend Drafting and Design. Pl a ns For: Roof Plan Scale: 1/8" =1'-0" 11" x 17" paper Scale: 1/4"=1'-0" 24" x 36" paper Pg 7 TW E B B C O N S T R U C T I O N Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) 179'-11 5/16" 42' 29 ' - 9 " 65 ' - 1 3 / 1 6 " 15 7 ' - 2 " 16 ' 96 ' - 1 9 / 1 6 " 1 8 0 '-1 1 /4 " 22 ' - 6 3 / 4 " 49'-9 11/16" 67'-7 1/4"5 0 '-1 1 5 /1 6 " RE V I S I O N T A B L E NU M B E R D A T E R E V I S E D B Y D E S C R I P T I O N DR A W I N G S P R O V I D E D B Y : DATE: Ri v e r B e n d D r a f t i n g a n d D e s i g n El i s e S h u r t l i f f 2 0 8 - 5 5 7 - 3 6 2 1 El i s e @ r i v e r b e n d h o u s e p l a n s . c o m 12/28/2021Plot Plan Mill Creek Estates Block 1 Lot 3 Building Parcel Madison County, Idaho General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by River Bend Drafting and Design. Pg 8 Pl a ns For: TW E B B C O N S T R U C T I O N North Pine Brook Estates Please show street location, street name and sidewalk location in Site plan DOOR SCHEDULE NUMBER LABEL QTY FLOOR SIZE WIDTH HEIGHT R/O DESCRIPTION HEADER THICKNESS CODE MANUFACTURER COMMENTS D01 2623 1 1 2623 L EX 30 " 27 " 32"X30" EXT. HINGED-SLAB 2X6X35" (2) 1 3/4" D02 2668 1 1 2668 L 30 " 80 " 30"X80" SHOWER-GLASS SLAB 1/2" D03 2668 1 1 2668 L 30 " 80 " 62"X82 1/2" POCKET-DOOR P04 2X6X65" (2) 1 3/8" D04 2668 2 1 2668 R IN 30 " 80 " 32"X82 1/2" HINGED-DOOR P04 2X6X35" (2) 1 3/8" D05 2868 1 1 2868 L 32 " 80 " 66"X82 1/2" POCKET-DOOR P04 2X6X69" (2) 1 3/8" D06 2868 1 1 2868 L IN 32 " 80 " 34"X82 1/2" HINGED-DOOR P04 2X6X37" (2) 1 3/8" D07 2868 1 1 2868 R 32 " 80 " 66"X82 1/2" POCKET-DOOR P04 2X6X69" (2) 1 3/8" D08 2868 1 1 2868 R IN 32 " 80 " 34"X82 1/2" HINGED-DOOR P04 2X6X37" (2) 1 3/8" D09 3068 1 1 3068 L 36 " 80 " 74"X82 1/2" POCKET-DOOR P04 2X6X77" (2) 1 3/8" D10 3068 3 1 3068 L EX 36 " 80 " 38"X83" EXT. HINGED-DOOR E21 2X6X41" (2) 1 3/4" D11 3068 1 1 3068 L IN 36 " 80 " 38"X82 1/2" HINGED-DOOR P04 2X6X41" (2) 1 3/8" D12 3068 1 1 3068 R IN 36 " 80 " 38"X82 1/2" HINGED-DOOR P04 2X6X41" (2) 1 3/8" D13 3680 1 1 3680 L EX 42 " 96 " 44"X99" EXT. HINGED-DOOR E21 2X6X47" (2) 1 3/4" D14 4068 1 1 4068 L/R IN 48 " 80 " 50"X82 1/2" DOUBLE HINGED-DOOR P04 2X6X53" (2) 1 3/8" D15 5068 2 1 5068 L/R IN 60 " 80 " 62"X82 1/2" DOUBLE HINGED-DOOR P04 2X6X65" (2) 1 3/8" D16 6068 1 1 6068 L/R IN 72 " 80 " 74"X82 1/2" DOUBLE HINGED-DOOR P04 2X6X77" (2) 1 3/8" D17 9080 3 1 9080 108 " 96 " 110"X99" GARAGE-GARAGE DOOR CHD05 2X12X116" (2) 1 3/4" WINDOW SCHEDULE NUMBER LABEL QTY FLOOR SIZE WIDTH HEIGHT R/O EGRESS DESCRIPTION HEADER CODE MANUFACTURER COMMENTS W01 2020RS 3 1 2020RS 24 " 24 " 25"X25" RIGHT SLIDING 2X6X28" (2) W02 3020FX 2 1 3020FX 36 " 24 " 37"X25" FIXED GLASS 2X6X40" (2) W03 3030SC 1 1 3030SC 36 " 36 " 37"X37"SINGLE CASEMENT-HR 2X6X40" (2) W04 3050SC 17 1 3050SC 36 " 60 " 37"X61"SINGLE CASEMENT-HR 2X6X40" (2) W05 4040RS 1 1 4040RS 48 "48 " 49"X49" RIGHT SLIDING 2X6X52" (2) window and door RE V I S I O N T A B L E NU M B E R D A T E R E V I S E D B Y D E S C R I P T I O N DR A W I N G S P R O V I D E D B Y : DATE: Ri v e r B e n d D r a f t i n g a n d D e s i g n El i s e S h u r t l i f f 2 0 8 - 5 5 7 - 3 6 2 1 El i s e @ r i v e r b e n d h o u s e p l a n s . c o m 12/28/2021 General Notes 1. Review entire set of plans including the above described with owner/contractor. 2. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. 3. This drawing is not to be duplicated without written or verbal consent by River Bend Drafting and Design. Pl a ns For: Window and Door Schedule WINDOW NOTES: 1 VINYL WINDOWS UNLESS OTHERWISE NOTED 2 INTERIOR WINDOW MATERIALS: FACTORY FINISH 3 WINDOW HARDWARE TO BE OWNER SELECTED AT TIME OF ORDER 4 WINDOW ROUGH OPENING: 1/2" FOR TOP/ BOTTOM & 1/2" FOR SIDES, UNO BY MFG. 5 BEDROOM WINDOWS SILL FINISHED MUST BE WITHIN 44: OF THE FLOOR AND PROVIDE MINIMUM CLEAR OPENINGS OF 5.7 SQ. FEET WITH HEIGHT DIMENSION NOT LESS THAN 24" AND WIDTH DIMENSION NOT LESS THAN 20" - HRC R310.1-R310.1.4 U-Factor - Rate of heat loss = 1/R SHGC - Solar Heat Gain Coefficient VLT - Visible Light Transmittance CR - Condensation Resistance Low- E4 / High Altitude Windows U-Factor SHGC VLT CR Casement/Hopper 0.39 .3 0.49 52 Double Hung 0.35 0.27 0.46 49 Slide-By 0.37 0.28 0.48 49 Fixed / Auxiliary 0.32 0.32 0.54 51 DOOR NOTES: 1. MAIN FLOOR DOORS SHALL BE 80"; SECOND FLOOR DOORS 80"; GARAGE DOOR 96", UNO. 2. ALL DOORS SHALL BE HOLLOW CORE 1 3/4" THICK, UNO 3. INTERIOR DOORS SHALL BE PAINTED, UNO. 4. DOORS BETWEEN GARAGE AND LIVING AREA SHALL BE 1 3/4" TIGHT FITTING SOLID CORE DOORS WITH A RATING OF 60 MINUTES. DOOR SHALL BE SELF CLOSING 5. EXTERIOR EXIT DOORS SHALL BE 36" MIN. NET CLEAR DOOR WAY SHALL BE 32" MIN. DOOR SHALL BE OPENABLE FROM INSIDE 6. GARAGE DOORS TO BE SECTIONAL, OVERHEAD DOORS. 7. ALL GLAZING WITHIN 18 IN. OF THE FLOOR AND/OR WITHIN 24 IN. OF ANY DOOR (REGARDLESS OF WALL PLANE) ARE TO HAVE SAFETY GLAZING. 8. ALL TUB AND SHOWER ENCLOSURES ARE TO BE GLAZED WITH SAFETY GLASS. Pg 9 TW E B B C O N S T R U C T I O N