HomeMy WebLinkAboutEWP LAYOUT - 21-01027 - 1139 Greenside Loop - New SFR16"oc
Start
J1
J10 J3J6
J2
J6
J9
J4J6J5J6J7J8R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
BKG1
BKG1
BKG1
Project
SPREX-2022-012
Layout Name
1139 Greenside Loop
Builder's Project
1139 Greenside Loop
Plan Name
Greenside
Shipping
1139 Greenside Loop
Rexburg, ID 83440, USA
Builder
TWebb Construction
Dealer
SunPro Rexburg
Capital Lumber
41 South 5100 West
Salt Lake City, UT
USA
84104
(801) 834-5141
Sales Rep
Jason Kelly
Designer
Jeff Harrop
Main Floor Framing
I Joist
Label Description Width Depth Qty Plies Pcs Length
J1 RFPI 400 2.063 11.875 5 12-0-0
J2 RFPI 400 2.063 11.875 5 16-0-0
J3 RFPI 400 2.063 11.875 16 26-0-0
J4 RFPI 400 2.063 11.875 3 32-0-0
J5 RFPI 400 2.063 11.875 4 36-0-0
J6 RFPI 400 2.063 11.875 13 40-0-0
J7 RFPI 400 2.063 11.875 3 48-0-0
J8 RFPI 400 2.063 11.875 9 52-0-0
J9 RFPI 400 2.063 11.875 4 2 8 4-0-0
J10 RFPI 400 2.063 11.875 5 2 10 14-0-0
Blocking
Label Description Width Depth Qty Plies Pcs Length
BKG1 RFPI 400 2.063 11.875 LinFt Varies 20-0-0
Rim Board
Label Description Width Depth Qty Plies Pcs Length
R1 Tolko Rim Board Plus
1.125 X 11.875
1.125 11.875 17 16-0-0
Decking
Qty Description
86 Sheets 23/32" OSB
Main Floor Framing
Design Method ASD (USA)
Building Code IBC 2018
Floor
Loads
Live 40
Dead 10
Deflection Joist
LL Span L/480
TL Span L/240
Deflection Flush Girder
LL Span L/480
TL Span L/240
Deflection Dropped Girder
LL Span L/480
TL Span L/240
Deflection Header
LL Span L/480
TL Span L/240
Decking
Decking OSB
23/32 APA Rated
Sturd-I-Floor
Fastener Nailed & Glued
1.JOIST TO BE SPACED AT 16"OC (TYPICAL)
2.DOUBLE JOIST PLACED BELOW ISLAND & FIREPLACE
3.ROOF LOADING HAS NOT BEEN APPLIED TO FLOOR SYSTEM
Version 21.80.417 Powered by iStructDataset: 21072908.3993 This placement plan is to be used as an installation guide only. It is meant to be used in conjunction with the manufacturers installation guide, the architectural and structural drawings, and not to replace them.
Version 21.80.417 Powered by iStructDataset: 21072908.3993 This placement plan is to be used as an installation guide only. It is meant to be used in conjunction with the manufacturers installation guide, the architectural and structural drawings, and not to replace them.