Loading...
HomeMy WebLinkAboutPLANS - 23-00873 - 6509 E 2000 N - Solar Panels1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. CU S T O M E R I N F O R M A T I O N : Th o m a s b a k e r 65 0 9 e a s t 2 0 0 0 n Su g a r C i t y I d a h o 8 3 4 4 8 AC S Y S T E M S I Z E : 6. 9 6 k W A C DC S Y S T E M S I Z E : 9. 6 k W D C DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore November 16, 2023 893571 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 COVER SHEET PV1 GENERAL NOTES CODE AND STANDARDS SITE NOTES / OSHA REGULATION SOLAR CONTRACTOR EQUIPMENT LOCATIONS AERIAL VIEW DESIGN CRITERIA WIND SPEED:115 mph GROUND SNOW LOAD:50 lb/ft² WIND EXPOSURE FACTOR:C SEISMIC DESIGN CATEGORY:C SITE SPECIFICATIONS CONSTRUCTION - V-B ZONING: RESIDENTIAL SHEET INDEX INS1 - INSTALL SHEET PV1 - COVER SHEET PV2 - SITE PLAN PV3 - ROOF PLAN PV4 - STRUCTURAL PV5 - ELECTRICAL 3-LINE DIAGRAM PV6 - ELECTRICAL CALCULATIONS PV7 - WARNING LABELS AND LOCATIONS PV8 - PLACARD (ALL OTHER SHEETS AS REQUIRED) SS - PRODUCT SPEC. SHEETS UTILITY COMPANY: Rocky Mountain Power ID PERMIT ISSUER: Madison County ID PROJECT INFORMATION: NUMBER OF STORIES:1 CONDUIT RUN:Interior ECOBEE QTY:0 LIGHT BULB QTY:0 PV METER:Not Required ROOF TYPE (1) INFORMATION: ROOF TYPE:Trapezoidal Metal FRAMING TYPE:Manufactured Truss SHEATHING TYPE:OSB ATTACHMENT:S-5! SolarFoot RACKING:Unirac Solarmount LT @ 24" OC Portrait / 32" OC Landscape NUMBER OF ATTACHMENTS:120 ROOF TYPE (2) INFORMATION (IF APPLICABLE): *SEE PV4.2 SCOPE OF WORK INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. SYSTEM TO BE INSTALLED INFORMATION: DC SYSTEM SIZE:9.6 kW DC AC SYSTEM SIZE:6.96 kW AC MODULE TYPE: (24) QCells Q.PEAK DUO BLK ML-G10+ /t 400 INVERTER TYPE:Enphase IQ8PLUS-72-2-US MONITORING:Enphase IQ Combiner 4 X-IQ-AM1-240-4 Sealed For Existing Roof and Attachment Only Brandon R. Little Digitally signed by Brandon R. Little Date: 2023.11.16 15:55:39 -07'00' DC AC DC AC DC AC DC AC DC AC DC AC DCAC DCAC DCAC DCAC DCAC DCAC DC AC DC AC DC AC DC AC DC AC DC AC DCAC DCAC DCAC DCAC DCAC DCAC M MSP CB AC SUB 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. CU S T O M E R I N F O R M A T I O N : Th o m a s b a k e r 65 0 9 e a s t 2 0 0 0 n Su g a r C i t y I d a h o 8 3 4 4 8 AC S Y S T E M S I Z E : 6. 9 6 k W A C DC S Y S T E M S I Z E : 9. 6 k W D C DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore November 16, 2023 893571 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 SITE PLAN PV2 SCALE: 3/64" = 1'-0" AC DISCONNECT TO BE WITHIN 3 FT OF METER M MSP AC CB LC SUB PV TS MAIN SERVICE PANEL UTILITY METER AC DISCONNECT COMBINER BOX LOAD CENTER SUBPANEL PV METER TRANSFER SWITCH JUNCTION BOX LEGEND FIRE SETBACK TRENCHING PROPERTY LINE ESS HUB RPO SUNPOWER ESS SUNPOWER HUB+ REMOTE POWER OFF PV SYSTEM SPECIFICATIONS TOTAL NUMBER OF MODULES:24 MODULE MAKE AND MODEL:QCells Q.PEAK DUO BLK ML-G10+ /t 400 MODULE WATTAGE:400W DC INVERTER MAKE AND MODEL:Enphase IQ8PLUS-72-2-US INVERTER TYPE: Microinverter (1 Inverter per PV Module) INVERTER CURRENT OUTPUT:1.21A AC INVERTER NOMINAL VOLTAGE: 240V INVERTER WATTAGE:290W AC FRONT OF HOME 6509 EAST 2000 N 11/16/2023 Sealed For Existing Roof and Attachment Only DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC DC AC M MSP CB AC SUB 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. CU S T O M E R I N F O R M A T I O N : Th o m a s b a k e r 65 0 9 e a s t 2 0 0 0 n Su g a r C i t y I d a h o 8 3 4 4 8 AC S Y S T E M S I Z E : 6. 9 6 k W A C DC S Y S T E M S I Z E : 9. 6 k W D C DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore November 16, 2023 893571 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 ROOF PLAN PV3 AC DISCONNECT TO BE WITHIN 3 FT OF METER SCALE: 3/32" = 1'-0" M MSP AC CB LC SUB PV TS MAIN SERVICE PANEL UTILITY METER AC DISCONNECT COMBINER BOX LOAD CENTER SUBPANEL PV METER TRANSFER SWITCH JUNCTION BOX LEGEND FIRE SETBACK TRENCHING PROPERTY LINE ESS HUB RPO SUNPOWER ESS SUNPOWER HUB+ REMOTE POWER OFF PV SYSTEM SPECIFICATIONS TOTAL NUMBER OF MODULES:24 MODULE MAKE AND MODEL:QCells Q.PEAK DUO BLK ML-G10+ /t 400 MODULE WATTAGE:400W DC INVERTER MAKE AND MODEL:Enphase IQ8PLUS-72-2-US INVERTER TYPE: Microinverter (1 Inverter per PV Module) INVERTER CURRENT OUTPUT:1.21A AC INVERTER NOMINAL VOLTAGE: 240V INVERTER WATTAGE:290W AC FRONT OF HOME POINT OF INTERCONNECTION OVERHEAD SERVICE LINE MP1 # OF MODULES: 24 AZIMUTH: 180 PITCH: 20 TSRF: 89% AREA: 736.65 ft.² CHIMNEY 11/16/2023 Sealed For Existing Roof and Attachment Only ATTACHMENT SPACING- SIDE VIEWDSCALE: 1/2" = 1'-0" LANDSCAPE PORTRAIT 10" MIN. 16" MAX. PV MODULE ROOF STRUCTURE 20° 2'-10" MIN. 3'-10" MAX. 10" MIN. 16" MAX. 1'-8" MIN. ATTACHMENT SPACING- FRONT VIEWCSCALE: 3/4" = 1'-0" PV MODULEUNIRAC UNIVERSAL AF MID CLAMP UNIRAC UNIVERSAL AF END CLAMP PV MODULEUNIRAC UNIVERSAL AF MID CLAMP UNIRAC UNIVERSAL AF END CLAMP " MAX.24" MAX. " MAX.32" MAX. A LANDSCAPE PORTRAIT S-5! SOLAR FOOT END CLAMP DETAILBSCALE: 3" = 1'-0" MID CLAMP DETAILASCALE: 3" = 1'-0" (E) ROOF SHEATHING (E) BUILDING STRUCTURE (E) TRAPEZOIDAL METAL ROOF (4) 1/4-14 TYPE 17 AB MILLED POINT 1-1/2" TO 2-1/2" S-5! SOLAR FOOT (4) 1/4-14 TYPE 17 AB MILLED POINT 1-1/2" TO 2-1/2" S-5! SOLAR FOOT (E) ROOF SHEATHING (E) BUILDING STRUCTURE (E) TRAPEZOIDAL METAL ROOF UNIRAC UNIVERSAL AF MID CLAMP QCELLS Q.PEAK DUO BLK ML-G10+ /T 400 PV MODULE UNIRAC SM RAIL LT UNIRAC L-FOOT UNIRAC UNIVERSAL AF END CLAMP QCELLS Q.PEAK DUO BLK ML-G10+ /T 400 PV MODULE UNIRAC L-FOOT UNIRAC SM RAIL LT 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. CU S T O M E R I N F O R M A T I O N : Th o m a s b a k e r 65 0 9 e a s t 2 0 0 0 n Su g a r C i t y I d a h o 8 3 4 4 8 AC S Y S T E M S I Z E : 6. 9 6 k W A C DC S Y S T E M S I Z E : 9. 6 k W D C DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore November 16, 2023 893571 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 STRUCTURAL PV4 STRUCTURAL INFORMATION: ROOF TYPE (1): ROOF TYPE: Trapezoidal Metal SHEATHING TYPE: OSB FRAMING TYPE: Manufactured Truss FRAMING SIZE: 2x4 @ 24" OC CEILING JOIST SIZE: 2x4 @ 24" OC ATTACHMENT: S-5! SolarFoot RACKING: Unirac Solarmount LT @ 24" OC Portrait / 32" OC Landscape NUMBER OF ATTACHMENTS: 120 PV MODULE COUNT: 24 Modules TOTAL ARRAY AREA: 489.6 ft² (20.4ft²/panel) TOTAL ROOF AREA: 4541.83 ft² ARRAY/ROOF AREA: 10.8% ARRAY WEIGHT: 1,200 lbs (50 lbs/panel) DISTRIBUTED LOAD: 2.45 lbs/ft² POINT LOAD: 10 lbs/attachment STRUCTURAL NOTES: None *NOTE: LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARY BASED ON FIELD CONDITIONS. MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PER ENGINEER OF RECORD SPECIFICATIONS. -RACKING ATTACHMENTS TO BE STAGGERED 11/16/2023 Sealed For Existing Roof and Attachment Only UTILITY COMPANY:Rocky Mountain Power ID PERMIT ISSUER: Madison County ID ELECTRICAL NOTES: ALL CONDUIT TO BE RAN AT LEAST 7/8 IN. ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT AC DISCONNECT TO BE WITHIN 3 FT OF METER DESIGNER NOTES: SUBPANEL BREAKER, POI INTERIOR. THIN 2 OF THE 20A BREAKERS. (1) CIRCUIT OF 12 MODULES (1) CIRCUIT OF 12 MODULES JB-1L1 L2 EGC L1 L2 (N) 20A / 2P L1 L2 EGC 12 JB L1 L2 EGC L1 L2 (N) 20A / 2P L1 L2 EGC 12 EGC N G 15A / 2P ENVOY (24) QCells Q.PEAK DUO BLK ML-G10+ /t 400 UL 1703 COMPLIANT (24) Enphase IQ8PLUS-72-2-US 1 PHASE, UL 1741 COMPLIANT ENPHASE IQ COMBINER 4 X-IQ-AM1-240-4 (SOLAR LOAD ONLY) 3 JB-1 EZ SOLAR JUNCTION BOX 4"x4"x4" PVC JUNCTION BOXPV AC DISCONNECT NON-FUSED LOCKABLE, VISIBLE OPEN 60A, 240V, 2-POLE L1 L2 N EGC 15120/240 VAC 60HZ 1 PHASE TO UTILITY GRID (E) 200A / 2P (E) LOADS (E) GROUNDING ELECTRODE(S) FEED THROUGH LUGS AT END OF BUSSING N G (N) 40A / 2P (E) LOADS N G (E) 200A MAIN SERVICE PANEL (E) 200A / 2P MAIN BREAKER L2 L1 N EGC L2 L1 N EGC (E) INTERCONNECTION NOTES 705.12(B)(3) THE FOLLOWING METHOD(S) SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS: (2) WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE POWER-SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUS BAR SHALL NOT EXCEED 12O PERCENT OF THE AMPACITY OF THE BUSBAR. 15 (E) 200A SUBPANEL (E) 200A / 2P 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. CU S T O M E R I N F O R M A T I O N : Th o m a s b a k e r 65 0 9 e a s t 2 0 0 0 n Su g a r C i t y I d a h o 8 3 4 4 8 AC S Y S T E M S I Z E : 6. 9 6 k W A C DC S Y S T E M S I Z E : 9. 6 k W D C DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore November 16, 2023 893571 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 ELECTRICAL PV5 GROUNDING NOTES 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690.47] AND [NEC 250.50-60] SHALL BE PROVIDED. PER [NEC 690.47], THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BE USED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER [NEC 250.64(C)]. 3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN 8 AWG AND NO GREATER THAN 6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.21], [NEC TABLE 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO [NEC 690.46]. 5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC 690.42]. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. 9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED, AND BARE WHEN EXPOSED. 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE A MINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TO DAMAGE). 12. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN (OR MARKED GREEN IF 4 AWG OR LARGER). 13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZED ACCORDING TO [NEC 250.166], MINIMUM 8 AWG WHEN INSULATED, 6 AWG WHEN EXPOSED TO DAMAGE. 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH [NEC 250.134] OR [NEC 250.136(A)] REGARDLESS OF VOLTAGE. WIRING & CONDUIT NOTES 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS. 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR (USE POLARIS BLOCK OR NEUTRAL BAR). 3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERS DISALLOWED ABOVE LIVE PARTS, MEYERS HUBS RECOMMENDED 4. UV RESISTANT CABLE TIES (NOT ZIP TIES) USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF SURFACE IN ACCORDANCE WITH [NEC 110.2,110.3(A-B)]. 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH WITH ROOF SURFACE TO BE USED FOR WIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2, AND SINGLE-CONDUCTOR CABLE LISTED AND IDENTIFIED AS PV WIRE, TYPE TC-ER, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED. 7. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC 690.8] FOR MULTIPLE CONDUCTORS. 8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8"ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(A)], [NEC TABLE 310.15(B)(3)(A)],& [NEC 310.15(B)(3)(C)]. 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 600V 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. 12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 13. VOLTAGE DROP LIMITED TO 2% FOR DC CIRCUITS AND 3% FOR AC CIRCUITS 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC POSITIVE- RED (OR MARKED RED), DC NEGATIVE- GREY (OR MARKED GREY) 15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: DC POSITIVE- GREY (OR MARKED GREY), DC NEGATIVE- BLACK (OR MARKED BLACK) 16. AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY * USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE ** USE-2 IS AVAILABLE AS UV WHITE 17. RIGID CONDUIT, IF INSTALLED, (AND/OR NIPPLES) MUST HAVE A PULL BUSHING TO PROTECT WIRES. 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTING MEANS SHALL COMPLY WITH [NEC 690.13] AND [NEC 690.15]. 19. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACE COMPLYING WITH [NEC 230.6(4)] AND SECURED NO GREATER THAN 6' APART PER [NEC 330.30(B)]. 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. CU S T O M E R I N F O R M A T I O N : Th o m a s b a k e r 65 0 9 e a s t 2 0 0 0 n Su g a r C i t y I d a h o 8 3 4 4 8 AC S Y S T E M S I Z E : 6. 9 6 k W A C DC S Y S T E M S I Z E : 9. 6 k W D C DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore November 16, 2023 893571 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 ELEC CALCS PV6 LABEL 1 FOR PV SYSTEM DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [2017 NEC 690.13(B)] [2020 NEC 690.13(B)] LABEL 2 SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT THE DISCONNECTING MEANS AS A POWER SOURCE AND WITH THE RATED AC OUTPUT CURRENT AND THE NOMINAL OPERATING AC VOLTAGE. [2017 NEC 690.54] [2020 NEC 690.54] LABEL 3 IF INTERCONNECTING LOAD SIDE, INSTALL THIS LABEL ANYWHERE THAT IS POWERED BY BOTH THE UTILITY AND THE SOLAR PV SYSTEM, IE. MAIN SERVICE PANEL AND SUBPANELS. [2017 NEC 705.12(B)(3)] [2020 NEC 705.12(B)(3)] LABEL 4 APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE POWER SOURCE. [2017 NEC 705.12(B)(2)(3)(b)] [2020 NEC 705.12(B)(3)(2)] LABEL 6 BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. [2017 NEC 690.56(C)(1)(a)] [2020 NEC 690.56(C)] LABEL 7 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [2017 NEC 690.56(C)(3)] [2020 NEC 690.56(C)(2)] LABEL 8 PERMANENT PLAQUE OR DIRECTORY DENOTING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. [2017 NEC 705.10] [2020 NEC 705.10] LABEL 9 PERMANENT PLAQUE OR DIRECTORY DENOTING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. [2017 NEC 705.10] [2020 NEC 705.10] LABEL 10 PERMANENT PLAQUE OR DIRECTORY TO BE LOCATED AT MAIN SERVICE EQUIPMENT DENOTING THE LOCATION OF THE RAPID SHUTDOWN SYSTEM DISCONNECTING MEANS IF SOLAR ARRAY RAPID SHUTDOWN DISCONNECTING SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [2017 NEC 705.10 AND 690.56(C)(1)(a)] [2020 NEC 705.10 AND 690.56(C)] LABEL 11 PERMANENT PLAQUE OR DIRECTORY TO BE LOCATED AT AC COMBINER PANEL. [2017 NEC 110.21(B)] [2020 NEC 110.21(B)] ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! PHOTOVOLTAIC SYSTEM AC DISCONNECT!! 240 VNOMINAL OPERATING AC VOLTAGE RATED AC OUTPUT CURRENT 29.04 A DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING! POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING! SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM MAIN DISTRIBUTION UTILITY DISCONNECT(S) POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY WITH A RAPID SHUTDOWN DISCONNECTING MEANS GROUPED AND LABELED WITHIN LINE OF SITE AND 10 FT OF THIS LOCATION WARNING! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM MAIN DISTRIBUTION UTILITY DISCONNECT LOCATED WARNING! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY. SOLAR ARRAY RAPID SHUTDOWN DISCONNECT IS LOCATED OUTSIDE NEXT TO THE UTILITY METER. WARNING! PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS WARNING! 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. CU S T O M E R I N F O R M A T I O N : Th o m a s b a k e r 65 0 9 e a s t 2 0 0 0 n Su g a r C i t y I d a h o 8 3 4 4 8 AC S Y S T E M S I Z E : 6. 9 6 k W A C DC S Y S T E M S I Z E : 9. 6 k W D C DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore November 16, 2023 893571 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 LABELS PV7 ADDITIONAL LABELS *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. UTILITY METER MAIN SERVICE PANEL 1 6 2 3 IF BREAKER IS USED4 8 10OR OR PLACARD SUBPANEL (IF INTERCONNECTION IS MADE HERE) 1 6 2 3 4 9 AC DISCONNECT 1 2 7 9 OR PLACARD PV COMBINER BOX 11 PV METER (IF APPLICABLE) LABELING NOTES 1) LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2) LABELING REQUIREMENTS BASED ON THE 2017 & 2020 NEC CODE, OSHA STANDARD 19010.145, ANSIZ535. 3) MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. 4) LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN [NEC 110.21] U10 PARALLEL GENERATION ON SITE LABEL U9 LABEL TO BE LOCATED AT UTILITY METER. MANUAL DISCONNECT FOR PARALLEL GENERATION LABEL U10 LABEL TO BE LOCATED AT PV AC DISCONNECT. U9 STANDARD LABELS 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. CU S T O M E R I N F O R M A T I O N : Th o m a s b a k e r 65 0 9 e a s t 2 0 0 0 n Su g a r C i t y I d a h o 8 3 4 4 8 AC S Y S T E M S I Z E : 6. 9 6 k W A C DC S Y S T E M S I Z E : 9. 6 k W D C DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore November 16, 2023 893571 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 PLACARD PV8 DIRECTORY PLACARD NOTES [NEC 705.10] A PERMANENT PLAQUE OR DIRECTORY DENOTING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. THE MARKING SHALL COMPLY WITH [110.21(B)]. 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry- leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) requirements © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8SP-DS-0002-01-EN-US-2022-03-17 * Only when installed with IQ System Controller 2, meets UL 1741. ** IQ8 and IQ8Plus supports split phase, 240V installations only. DATA SHEET (1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8 and IQ8+ Microinverters INPUT DATA (DC) IQ8-60-2-US IQ8PLUS-72-2-US Commonly used module pairings1 W 235 – 350 235 – 440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell, 66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27 – 37 29 – 45 Operating range V 25 – 48 25 – 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current2 [module Isc]A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ8-60-2-US IQ8PLUS-72-2-US Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal (L-L) voltage/range3 V 240 / 211 – 264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50 – 68 AC short circuit fault current over 3 cycles Arms 2 Max units per 20 A (L-L) branch circuit4 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable) 0.85 leading – 0.85 lagging Peak efficiency %97.5 97.6 CEC weighted efficiency %97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD) 212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8SP-DS-0002-01-EN-US-2022-03-17 IQ8PLUS-72-2-US 235 – 440 60-cell/120 half-cell, 66-cell/132 half-cell and 72-cell/144 half-cell 29 – 45 25 – 58 30 / 58 60 IQ8PLUS-72-2 -US 300 290 IQ8PLUS 72 2 US 290 1.21 13 97.6 9797 DRAWING NUMBER:SS BLUE RAVEN SOLAR The Enphase Q Cable™ and accessories are part of the latest generation Enphase IQ System™. These accessories provide simplicity, reliability, and faster installation times. Enphase Q Cable Accessories To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Q Cable Accessories REGION: Americas Enphase Q Cable • Two-wire, double-insulated Enphase Q Cable is 50% lighter than the previous generation Enphase cable • New cable numbering and plug and play connectors speed up installation and simplify wire management • Link connectors eliminate cable waste Field-Wireable Connectors • Easily connect Q cables on the roof without complex wiring • Make connections from any open connector and center feed any section of cable within branch limits • Available in male and female connector types To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-06-26 CONDUCTOR SPECIFICATIONS 'IVXMƤGEXMSR UL3003 (raw cable), UL 9703 (cable assemblies), DG cable Flame test rating FT4 Compliance RoHS, OIL RES I, CE, UV Resistant, combined UL for Canada and United States Conductor type THHN/THWN-2 dry/wet Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Q CABLE TYPES / ORDERING OPTIONS Connectorized Models Size / Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG / 277 VAC 1.3 m (4.2 ft) Portrait 240 Q-12-17-240 12 AWG / 277 VAC 2.0 m (6.5 ft) Landscape (60-cell) 240 Q-12-20-200 12 AWG / 277 VAC 2.3 m (7.5 ft) Landscape (72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Field-wireable connector (male)Q-CONN-10M Make connections from any open connector Field-wireable connector (female)Q-CONN-10F Make connections from any Q Cable open connector Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount Q Cable sealing caps (female)Q-SEAL-10 One needed to cover each unused connector on the cabling Terminator Q-TERM-10 Terminator cap for unused cable ends Enphase EN4 to MC4 adaptor¹ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4 (TE PV4-S SOLARLOK). 150mm/5.9” to MC4. Enphase EN4 non-terminated adaptor¹ECA-EN4-FW *SVƤIPH[MVMRKSJ90GIVXMƤIH('GSRRIGXSVW)2 8)4:7730 %603/ XS non-terminated cable. 150mm/5.9” Enphase EN4 to MC4 adaptor (long)¹ECA-EN4-S22-L Longer adapter cable for EN4 (TE PV4-S SOLARLOK) to MC4. Use with split cell modules or PV modules with short DC cable. 600mm/23.6” Replacement DC Adaptor (MC4)Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC) Replacement DC Adaptor (UTX)Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC) 1. 5YEPMƤIHTIV90WYFNIGX Enphase Q Cable Accessories TERMINATOR Terminator cap for unused cable ends, sold in packs of ten (Q-TERM-10) SEALING CAPS Sealing caps for unused aggregator and cable connections (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL Plan to use at least one per installation, sold in packs of ten (Q-DISC-10) CABLE CLIP Used to fasten cabling to the racking or to secure looped cabling, sold in packs of one hundred (Q-CLIP-100) 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block! NOW FEATURING FLASHKIT PRO The Complete Roof Attachment Solution NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here! REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps THE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNT OPTIONAL FRONT TRIM New & Improved: THE PROFESSIONALS’ CHOICEWith Superior Aesthetics CONCEALED UNIVERSAL CLAMPS W WITH UNIVERSAL MIDCLAMPWITHUNIVERSRSRSSSALALALALMMIIDCLAMP 25 YEAR FULL-SYSTEM WARRANTY FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY BETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOL Start the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information. UNIVERSAL SELF STANDING MIDCLAMPS U-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit design.unirac.com BANKABLE WARRANTY Don’t leave your project to chance, Unirac has the ƛQDQFLDOVWUHQJWKWREDFNRXUSURGXFWVDQGUHGXFH\RXUULVN Have peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year OLPLWHGSURGXFWZDUUDQW\DQGD\HDUOLPLWHGƛQLVKZDUUDQW\ TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly VLPSOLƛHV\RXUSHUPLWWLQJDQGSURMHFWSODQQLQJSURFHVV CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO FHUWLƛFDWLRQVIRUDQG2+6$6 18001:2007, which means we deliver the highest standards IRUƛWIRUPDQGIXQFWLRQ7KHVHFHUWLƛFDWLRQVGHPRQVWUDWH RXUH[FHOOHQFHDQGFRPPLWPHQWWRƛUVWFODVVEXVLQHVVSUDFWLFHV UL2703 BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATIONLI S T E D SOLARMOUNT CONCEALED UNIVERSAL ENDCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702PUB2018AUG31 – PRINTED UPDATE 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SM SOLAR MOUNT INSTALLATION GUIDE PAGE Wrench or Socket Size Recommended Torque (ft-lbs) Mid Clamp u 1/2” 11 MLPE Mount v 1/2” 10 End Clamp t 1/2”5 L-Foot to Rail s 1/2” 30 Rail Splice p 1/2” 10 Anti-Seize PRO SERIES SYSTEM COMPONENTS A n o p q r u v SM LIGHT RAIL SM STANDARD RAILnnnnnnnnn t s nRAIL: Supports PV modules. Use at least two per row of modules. Aluminum extrusion, available in mill, clear anodized, or dark anodized. opRAIL SPLICE: Non structural splice joins, aligns, and electrically bonds rail sections into single length of rail. Forms a rigid splice joint, 4 inches long, preassembled with bonding hardware. $YDLODEOHLQGDUNDQRGL]HGRUPLOOʳQLVK qL-FOOT:8VHWRVHFXUHUDLOVWKURXJKURRʳQJ material to building structure. Refer to loading tables or U-Builder for spacing. r L-FOOT T- BOLT: (3/8” x ¾" or 1”) – Use one per L-foot to secure rail to L-foot. Stainless steel. 6XSSOLHGZLWK/IRRWLQFRPELQDWLRQZLWKʴDQJH nut, provides electrical bond between L-foot and rail. sSERRATED FLANGE NUT : Use one per L-foot to secure and bond rail to Lfoot. Stainless steel. Supplied with L-foot. tMODULE ENDCLAMP: Pre-assembled universal clamp that secures module to rail at module ʴDQJHE\WLJKWHQLQJKH[KHDGEROW uMODULE MIDCLAMP: Pre-assembled clamp provides module to module and module to rail bond. Aluminum clamp with stainless steel bonding pins and T-bolt. Available in clear or GDUNʳQLVK vMICROINVERTER MOUNTING BOLT: Preassembled bolt, nut, and captive star washer attaches and bonds microinverter to rail. NOTE - POSITION INDICATOR: T-bolts have a slot in the hardware end corresponding to the direction of the T-Head. NOTE - Pro Series Mid and End Clamps are single use only Wrenches and Torque Stainless steel hardware can seize up, a process called JDOOLQJ7RVLJQLʳFDQWO\UHGXFHLWVOLNHOLKRRG 1. Apply minimal lubricant to bolts only where indicated in installation process, preferably Anti-Seize commonly found at auto parts stores (Anti-seize has been factory applied to mid clamp bolts) 2. Shade hardware prior to installation, and 3. Avoid spinning stainless nuts onto bolts at high speed. sv See Appendix C for Universal AF Installation* See Appendix C for Universal AF Installation* 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SM SOLAR MOUNT INSTALLATION GUIDE PAGE SYSTEM LEVEL FIRE CLASSIFICATION 7KHV\VWHPʳUHFODVVUDWLQJUHTXLUHVLQVWDOODWLRQLQWKHPDQQHUVSHFLʳHGLQWKH62/$502817,QVWDOODWLRQ*XLGH62/$502817KDVEHHQFODVVLʳHGWRWKHV\VWHP OHYHOʳUHSRUWLRQRI8/62/$502817KDVDFKLHYHGV\VWHPOHYHOSHUIRUPDQFHIRUVWHHSVORSHGURRIV7KHʳUHFODVVLʳFDWLRQUDWLQJLVRQO\YDOLGRQURRISLWFKHV JUHDWHUWKDQ VORSHVɇLQFKHVSHUIRRWRUGHJUHHV 7KHV\VWHPLVWREHPRXQWHGRYHUʳUHUHVLVWDQWURRIFRYHULQJUDWHGIRUWKHDSSOLFDWLRQ7KHUHLVQR UHTXLUHGPLQLPXPRUPD[LPXPKHLJKWOLPLWDWLRQDERYHWKHURRIGHFNWRPDLQWDLQWKHV\VWHPʳUHUDWLQJIRU62/$5028170RGXOH7\SHV6\VWHP/HYHO)LUH5DWLQJV and Mitigation Requirements are listed below: SM STANDARD RAIL SM LIGHT RAIL CODE COMPLIANCE NOTES Rail Type Module Fire Types System Level Fire Rating Rail Direction Module Orientation Mitigation Required 6WDQGDUG +'5DLOV 1, 2, 3 with Metal Frame, 10 with Metal )UDPH  &ODVV$&ODVV% &ODVV&East-West Landscape OR Portrait None Required North-South Landscape OR Portrait None Required Light Rail   &ODVV$&ODVV% &ODVV&East-West Landscape OR Portrait None Required North-South Landscape OR Portrait None Required 6WDQGDUG/LJKW  HD Rails   &ODVV$&ODVV% &ODVV&East-West Landscape OR Portrait Trim installation per Solar Mount Installation GuideNorth-South Landscape OR Portrait C 7KLVUDFNLQJV\VWHPPD\EHXVHGWRJURXQGDQGRUPRXQWD39PRGXOHFRPSO\LQJZLWK8/RU8/RQO\ZKHQWKHVSHFLʳFPRGXOHKDVEHHQHYDOXDWHGIRU grounding and/or mounting in compliance with the included instructions. UL2703 CERTIFICATION MARKING LABEL 8QLUDF62/$502817LVOLVWHGWR8/&HUWLʳFDWLRQPDUNLQJLVHPERVVHGRQDOOPLGFODPSVDVVKRZQ/DEHOVZLWK additional information will be provided . After the racking system is fully assembled, a single label should be applied to the SOLARMOUNT rail at the edge of the array. Before applying the label, the corners of the label that do not pertain to the system being installed must be removed so that only the installed system type is showing. Note: The sticker label should be placed such that it is visible, but not outward facing. LLLLLIIIIIGGGGGGGHHHHHHHTTTTTTT RRRRRRAAAAAAIIIIILLLLL 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SM SOLAR MOUNT INSTALLATION GUIDE PAGE MICROINVERTER SYSTEM GROUNDING SM EQUIPMENT GROUNDING THROUGH ENPHASE MICROINVERTERS The Enphase M215 and M250 microinverters have integrated grounding capabilities built in. In this case, the DC circuit is isolated from the AC circuit, and the AC equipment grounding conductor (EGC) is built into the Enphase Engage integrated grounding (IG) cabling. In order to ground the SOLARMOUNT racking system through the Enphase microinverter and Engage cable assembly, there must be a minimum of three PV modules connected to the same trunk cable within a continuous row. &RQWLQXRXVURZLVGHʳQHGDVDJURXSLQJRIPRGXOHVLQVWDOOHGDQGERQGHGSHU the requirements of this installation guide sharing the same two rails. The microinverters are bonded to the SOLARMOUNT rail via the mounting hardware. Complete equipment grounding is achieved through the Enphase Engage cabling with integrated grounding (IG). No additional EGC grounding cables are required, as all fault current is carried to ground through the Engage cable. Í SOLARMOUNT INTEGRATED BONDING ADVANTAGE WITH SYSTEM GROUNDING THROUGH ENPHASE MICROINVERTERS AND TRUNK CABLES LOSE ALL THE COPPER & LUGS I 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SM SOLAR MOUNT INSTALLATION GUIDE PAGE GROUNDING LUG MOUNTING DETAILS: Details are provided for both the WEEB and Ilsco products. The WEEBLug has a grounding symbol located on the lug assembly. The Ilsco lug has a green colored set screw for grounding indication purposes. Installation must be in accordance with NFPA NEC 70, however the electrical designer of record should refer to the latest revision of NEC for actual grounding conductor cable size. Required if not using approved integrated grounding microinveters WEEBLUG CONDUCTOR - UNIRAC P/N 008002S: Apply Anti Seize and insert a bolt in the aluminum rail and through the clearance hole LQWKHVWDLQOHVVVWHHOʴDWZDVKHU3ODFHWKHVWDLQOHVVVWHHOʴDWZDVKHURQWKHEROW oriented so the dimples will contact the aluminum rail. Place the lug portion on the EROWDQGVWDLQOHVVVWHHOʴDWZDVKHU,QVWDOOVWDLQOHVVVWHHOʴDWZDVKHUORFNZDVKHUDQG nut. Tighten the nut until the dimples are completely embedded into the rail and lug. TORQUE VALUE 10 ft lbs. (See Note on PG. A) See product data sheet for more details, Model No. WEEB-LUG-6.7 ILSCO LAY-IN LUG CONDUCTOR - UNIRAC P/N 008009P: Alternate Grounding Lug - Drill, deburr hole and bolt thru both rail walls per table. TORQUE VALUE 5 ft lbs. (See Note on PG. A) See ILSCO product data sheet for more details, Model No. GBL-4DBT. NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION GROUNDING LUG - BOLT SIZE & DRILL SIZE GROUND LUG BOLT SIZE DRILL SIZE WEEBLug 1/4" N/A - Place in Top SM Rail Slot IlSCO Lug #10-32 7/32" • Torque value depends on conductor size. • See product data sheet for torque value. STANDARD SYSTEM GROUNDING K Í ONLY ONE LUG PER ROW OF MODULES: Only one lug per row of modules is required. See Page F for additional lugs required for expansion joints. TERMINAL TORQUE, Install Conductor and torque to the following: 4-6 AWG: 35in-lbs 8 AWG: 25 in-lbs 10-14 AWG: 20 in-lbs Star Washer is Single Use Only WEEBLUG Single Use Only TERMINAL TORQUE, Install Conductor and torque to the following: 6-14 AWG: 5ft-lbs 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SM SOLAR MOUNT INSTALLATION GUIDE PAGE Stainless steel Midclamp points, 2 per module, pierce module frame anodization to bond module to module through clamp. 6HUUDWHGʴDQJHQXWERQGVVWDLQOHVVVWHHOFODPS to stainless steel T-bolt Serrated T-bolt head penetrates rail anodization to bond T-bolt, nut, clamp, and modules to grounded SM rail. BONDING MIDCLAMP ASSEMBLY ENDCLAMP ASSEMBLY BONDING MICROINVERTER MOUNT RAIL TO L-FOOT w/BONDING T-BOLT BONDING RAIL SPLICE BAR RACK SYSTEM GROUND 6HUUDWHGʴDQJHQXWERQGVDOXPLQXP(QGFODPS to stainless steel T-bolt Serrated T-bolt head penetrates rail anodization to bond T-bolt, nut, and Endclamp to grounded SM rail Note: End clamp does not bond to module frame. MO D U L E F R A M E MO D U L E F R A M E BONDING CONNECTION GROUND PATHS Y Hex nut with captive lock washer bonds metal PLFURLQYHUWHUʴDQJHWRVWDLQOHVVVWHHO7EROW Serrated T-bolt head penetrates rail anodization to bond T-bolt, nut, and L-foot to grounded SM rail System ground including racking and modules may be achieved through the trunk cable of approved microinverter systems. See page J for details WEEB washer dimples pierce anodized rail to create bond between rail and lug Solid copper wire connected to lug is routed to SURYLGHʳQDOV\VWHPJURXQGFRQQHFWLRQ NOTE: Ilsco lug can also be used when secured to the side of the rail. See page K for details WEEBLUG (OR ILSCO LUG) SM R A I L SM R A I L SM R A I L SM R A I L SM R A I L SM R A I L SM R A I L SM R A I L MO D U L E F R A M E BON D I N G T - B O L T 2 2 2 2 2 2 2 22 1 1 1 1 1 1 1 11 3 3 BO N D I N G T - B O L T SERRATED NUT SPLIC E B A R SM RA I L MICRO - I N V E R T E R F L A N G E SEE NOTESEE NOTE HEX NUT W/ CAPTIVE LOCK WASHER BONDING T-BOLT SO L I D C O P P E R W I R E BONDING MICROINVERTER MOUNT EN D C L A M P A S S E M B L Y BO N D I N G M I D C L A M P AS S E M B L Y RA C K S Y S T E M G R O U N D Note: Only one lug per module row required BOND I N G H A R D W A R E ACBD E F AB D C EF Gr o u n d L u g w / B a r e C o p p e r W i r e Gr o u n d L u g w / B a r e C o p p e r W i r e BONDING RAIL SPLICE BAR Bonding Hardware creates bond between splice bar and each rail section Aluminum splice bar spans across rail gap to create rail to rail bond. Rail on at least one side of splice will be grounded. Note: Splice bar and bolted connection are non-structural. The splice bar function is rail alignment and bonding. 2 1 RAIL TO L-FOOT w/BONDING T-BOLT 6HUUDWHGʴDQJHQXWUHPRYHV/IRRWDQRGL]DWLRQ to bond L-Foot to stainless steel T-bolt Serrated T-bolt head penetrates rail anodization to bond T-bolt, nut, and L-foot to grounded SM rail SM R A I L SM R A I L 2 2 1 SERRA T E D F L A N G E N U T L-F O O T B O N D I NG T-B O L T 1 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SM SOLAR MOUNT INSTALLATION GUIDE PAGE BONDING CONNECTION GROUND PATHS Z TEMPORARY BONDING CONNECTION DURING ARRAY MAINTENANCE When removing modules for replacement or system maintenance, any module left in place that is secured with a bonding Midclamp will be properly grounded. If a module adjacent to the end module of a row is removed or if any other maintenance condition leaves a module without a bonding mid clamp, a temporary bonding connection must be installed as shown • Attach Ilsco SGB4 to wall of rail • Attach Ilsco SGB4 to module frame • Install solid copper wire jumper to Ilsco lugs MODULE REMOVED BONDING MID CLAMPS MAINTAIN GROUND PATH Ilsco S G B - 4 Ilsco S G B - 4 SOLID C O P P E R W I R E TEMPORARY BONDING CONNECTION ELECTRICAL CONSIDERATIONS SOLARMOUNT is intended to be used with PV modules that have a system voltage less than or equal to that allowable by the NEC. For standard system grounding a minimum 10AWG, 105°C copper grounding conductor should be used to ground a 1000 VDC system, according to the National Electric Code (NEC). It is the installer’s responsibility to check local codes, which may vary. See below for interconnection information. INTERCONNECTION INFORMATION There is no size limit on how many SOLARMOUNT 39PRGXOHVFDQEHPHFKDQLFDOO\LQWHUFRQQHFWHG IRU DQ\ JLYHQ FRQʳJXUDWLRQ SURYLGHG WKDW WKH installation meets the requirements of applicable EXLOGLQJDQGʳUHFRGHV GROUNDING NOTES The installation must be conducted in accordance with the National Electric Code (NEC) and the authority having jurisdiction. Please refer to these resources in your location for required grounding lug TXDQWLWLHVVSHFLʳFWR\RXUSURMHFW The grounding / bonding components may overhang parts of the array so care must be made when walking around the array to avoid damage. Conductor fastener torque values depend on conductor size. See product data sheets for correct torque values. REQUIRED ONLY FOR TEMPORARY BONDING DURING ARRAY MAINTENANCE 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SM SOLAR MOUNT SYSTEM CERTIFICATION PAGE 31COMPATIBLE MODULES ȫ 8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID ȫ 7KHIUDPHSURʳOHPXVWQRWKDYHDQ\IHDWXUHWKDWPLJKWLQWHUIHUHZLWKWKHERQGLQJGHYLFHVWKDWDUHLQWHJUDWHGLQWRWKHUDFNLQJV\VWHP • Use with a maximum over current protection device OCPD of 30A •/LVWHGPRGHOVFDQEHXVHGWRDFKLHYHD&ODVV$ʳUHV\VWHPUDWLQJIRUVWHHSVORSHDSSOLFDWLRQV6HHSDJH Manufacture Module Model / Series Aionrise AION60G1, AION72G1 Aleo 36HULHV 66HULHV Aptos Solar DNA-120-(MF/BF)10-xxxW DNA-120-MF10 DNA-120-(MF/BF)23 DNA-144-(MF/BF)23 DNA-120-(MF/BF)26 DNA-144-(MF/BF)26 DNA-108-(MF/BF)10-xxxW Astronergy CHSM6612 M, M/HV CHSM6612P Series CHSM6612P/HV Series CHSM72M-HC CHSM72M(DG)/F-BH Auxin $;107 $;137 $;107 $;137 Axitec AC-xxx(M/P)/60S, AC-xxx(M/P)/72S AC-xxxP/156-60S AC-xxxMH/120(S/V/SB/VB) AC-xxxMH/144(S/V/SB/VB) Boviet BVM6610, BVM6612 BYD 3. 0+.6HULHV Canadian Solar CS1(H/K/U/Y)-MS CS3K-(MB/MB-AG/MS/P/P HE/PB-AG) CS3L-(MS/P) CS3N-MS CS3U-(MB/MB-AG/MS/P/P HE/PB/PB-AG) CS3W-(MS/MB-AG/P/P-PB-AG) CS3Y-MB-AG Manufacture Module Model / Series Canadian Solar (cont.) CS5A-M CS6K-(M/MS/MS AllBlack/P/P HE) CS6P-(M/P) CS6R-MS CS6U-(M/P/P HE) CS6W-(MS/MB-AG) &6;3&6;3 ELPS CS6(A/P)-MM Centrosolar America &6HULHV (6HULHV CertainTeed CT2xxMxx-01, CT2xxPxx-01, CTxxxMxx-01 CTxxxPxx-01, CTxxxMxx-02, CTxxxMxx-03 CTxxxMxx-04, CTxxxHC11-04 Eco Solargy 2ULRQ $SROOR EMMVEE ExxxP72-B ExxxM72-B ExxxH CM120-B ET Solar ET AC Module, ET Module ET-M772BH520-550WW/WB First Solar )6;;; $ )6;;; $ 3)6;;; $ 3, Flextronics );6[[[%% Freedom Forever FF-MP-BBB-xxx, FF-MP1-BBB-xxx FreeVolt PVGraf GCL *&/3 *&/06HULHV Hansol TD-AN3, TD-AN4 UB-AN1, UD-AN1 Hanwha SolarOne HSL 60 Manufacture Module Model / Series Heliene 03030 36HULHV 144HC M6 144HC M10 SL Bifacial HT-SAAE HT60-156M-C HT60-156M(V)-C HT72-156(M/P) HT72-156P-C, HT72-156P(V)-C HT72-156M(PDV)-BF, HT72-156M(PD)-BF +70+7; Hyperion Solar HY-DH108P8(B), HY-DH108N8B HY-DH144P8 Hyundai KG, MG, RW, TG, RI, RG, TI, KI, HI Series HiA-SxxxHG, HiD-SxxxRG(BK), HiS-S400PI HiS-SxxxYH(BK) +L66[[[;* %. +L16[[[;* %. ITEK iT-SE Series Japan Solar -36 -366HULHV JA Solar JAM54S31 xxx/MR JAM72D30MB, JAM78D10MB JAM72S30 /MR JAP6 60-xxx JAM6(K)-60/xxx, JAP6(k)-72-xxx/4BB -$36[[[ -$3 N [[[%%-$36[[[ -$0 N [[[ -$06[[[ -$0 N [[[ -$06[[[ i. ##: 01, 02, 03, 09, 10 LL 6&35%3+L7,%0:05  %DFNVKHHW&HOOWHFKQRORJ\ Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the SOLARMOUNT system. 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SM SOLAR MOUNT SYSTEM CERTIFICATION PAGE 32COMPATIBLE MODULES Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the SOLARMOUNT system. Manufacture Module Model / Series Jinko -.0 -.066HULHV JKMxxxM-72HL-V JKMxxxM-72HL4-(T)V JKMxxxM-72HLM-TV JKMxxxM-7RL3-V JKMxxxM-72HL4-TV Kyocera .') .86HULHV LA Solar LSxxxHC(166) LSxxxBL LSxxxHC LG Electronics LGxxx(E1C/E1K/N1C/N1K/N2T/N2W/S1C/ S2W/Q1C/Q1K)-A5 LGxxx(A1C/M1C/M1K/N1C/N1K/Q1C/Q1K/ QAC/QAK)-A6 LGxxxN2W-B3 LGxxxN2T-B5 LGxxxN1K-B6 LGxxx(N1C/N1K/N2T/N2W)-E6 LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 LGxxxN2T-J5 LGxxx(N1K/N1W/N2T/N2W)-L5 LGxxx(M1C/N1C/Q1C/Q1K)-N5 LGxxx(N1C/N1K/N2W/Q1C/Q1K)-V5 LGxxxN3K-V6 LONGi LR4-60(HPB/HPH) LR4-72(HPH) LR6-60 LR6-60(BK/HPB/HPH/HV/PB/PE/PH) LR6-72 LR6-72(BK/HV/PB/PE/PH) RealBlack LR4-60HPB RealBlack LR6-60HPB Manufacture Module Model / Series Maxeon 6350$;[[[&20 Meyer Burger Meyer Burger Black, Meyer Burger White Meyer Burger Glass Mission Solar Energy MSE Mono, MSE Perc 06([[[ 65765.6566;7 06([[[ 6;.6;: Mitrex Mxxx-L3H, Mxxx-I3H Mitsubishi 0-( 0/(6HULHV Neo Solar Power Co. D6M Series NE Solar NESE xxx-72MHB-M10 NESE xxx-60MH-M6 Panasonic VBHNxxxSA06/SA06B/SA11/SA11B VBHNxxxSA15/SA15B/SA16/SA16B, VBHNxxxKA, VBHNxxxKA03/04, VBHNxxxSA17/SA17G/SA17E/SA18/SA18E, VBHNxxxZA01/ZA02/ZA03/VBHNxxxZA04 EVPVxxx EVPVxxx(H/K/PK/HK) Peimar SGxxxM (FB/BF) SMxxxM Phono Solar PSxxxM1-20/U PSxxxM1H-20/U PSxxxM1-20UH PSxxxM1H-20UH PSxxxM4(H)-24/TH PSxxxM1-20/UH PSxxxM1H-20/UH PSxxxM-24/T PSxxxMH-24/T PSxxxM-24/TH PSxxxMH-24/TH Manufacture Module Model / Series Prism Solar 36HULHV3;[[[ Q.Cells Plus, Pro, Peak, G3, G4, Peak G5(SC) , G6(+)(SC)(AC), G7, G8(+), Plus, Pro, Peak L-G2, L-G4, L-G5 Peak L-G5, L-G6, L-G7, L-G8(BFF) Q.PEAK DUO( BLK)-G6+ Q.PEAK DUO BLK-G6+/TS Q.PEAK DUO (BLK)-G7 Q.PEAK DUO L-(G7/G7.1/G7.2/G7.3/G7.7) Q.PEAK DUO (BLK) G8(+) Q.PEAK DUO L-(G8/G8.1/G8.2/G8.3) Q.PEAK DUO L-G8.3 (BFF/BFG/BGT) Q.PEAK DUO (BLK) ML-G9(+) 43($.'82;/ *** 43($.'82;/*%)* Q.PEAK DUO-G10+ Q.PEAK DUO BLK G10(+) Q.PEAK DUO BLK G10+ /AC Q.PEAK DUO (BLK) ML-G10(a)(+) Q.PEAK DUO BLK ML-G10+ / t 43($.'82;/ ****F G10.d) 43($.'82;/*%)* 43($.'82;/*G%)* 43($.'82;/ ** 43($.'82;/*%)* ȫ 8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID ȫ 7KHIUDPHSURʳOHPXVWQRWKDYHDQ\IHDWXUHWKDWPLJKWLQWHUIHUHZLWKWKHERQGLQJGHYLFHVWKDWDUHLQWHJUDWHGLQWRWKHUDFNLQJV\VWHP • Use with a maximum over current protection device OCPD of 30A •/LVWHGPRGHOVFDQEHXVHGWRDFKLHYHD&ODVV$ʳUHV\VWHPUDWLQJIRUVWHHSVORSHDSSOLFDWLRQV6HHSDJH 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SM SOLAR MOUNT SYSTEM CERTIFICATION PAGE 33COMPATIBLE MODULES Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the SOLARMOUNT system. Manufacture Module Model / Series REC RECxxxAA (BLK/Pure/Pure-R) RECxxxNP (N-PEAK) RECxxxNP2 (Black) RECxxxNP3 Black RECxxxPE, RECxxxPE72 RECxxxTP, RECxxxTP72 RECxxxTP2(M/BLK2) RECxxxTP2S(M)72 RECxxxTP3M (Black) RECxxxTP4 (Black) Renesola All 60-cell modules Risen RSM Series, RSM110-8-xxxBMDG SEG Solar SEG-xxx-BMD-HV SEG-xxx-BMD-TB S-Energy 61 616HULHV Seraphim SEG-(6PA/6PB/6MA/6MA-HV/6MB/E01/E11) SRP-(6QA/6QB) SRP-xxx-6MB-HV, SRP-320-375-BMB-HV, SRP-xxx-BMC-HV, SRP-390-450-BMA-HV, SRP-xxx-BMZ-HV, SRP-390-405-BMD-HV Sharp 186$ 186&6HULHV Silfab 6/$06/$36/*06/*3 %&6HULHV SIL-xxx(BG/BK/BL/HC/HC+/HL/HM/HN/ML/ 1/171;18 Solar4America S4Axxx-108MH10BB, S4Axxx-72MH5BB ȫ 8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID ȫ 7KHIUDPHSURʳOHPXVWQRWKDYHDQ\IHDWXUHWKDWPLJKWLQWHUIHUHZLWKWKHERQGLQJGHYLFHVWKDWDUHLQWHJUDWHGLQWRWKHUDFNLQJV\VWHP • Use with a maximum over current protection device OCPD of 30A •/LVWHGPRGHOVFDQEHXVHGWRDFKLHYHD&ODVV$ʳUHV\VWHPUDWLQJIRUVWHHSVORSHDSSOLFDWLRQV6HHSDJH Manufacture Module Model / Series SolarEver USA 6( [[[01 6( [[[01 Solaria 3RZHU;7[[[5 $&3'%' 3RZHU;7[[[&3' 3RZHU;7[[[530 $& 3RZHU;5 Solartech 678+-76783(5& 4XDQWXP3(5& SolarWorld Sunmodule Protect, Sunmodule Plus/Pro Sonali SS-M-360 to 390 Series SS-M-390 to 400 Series SS-M-440 to 460 Series SS-M-430 to 460 BiFacial Series Sun Edison F-Series, R-Series Suniva 096HULHV 2SWLPXV6HULHV PP Sunmac Solar M754SH-BB Series SunPower $&;6HULHV(6HULHV 36HULHV SPR E20 435 COM (G4 Frame) Axxx-BLK-G-AC, SPR-Mxxx-H-AC SPR-Mxxx-H-AC SunTech 673673;;;6%:QKE Talesun TP572, TP596, TP654, TP660 TP672, Hipor M, Smart, TD6I72M Tesla SC, SC B, SC B1, SC B2, TxxxS, TxxxH Trina PA05, PD05, DD05, DD06, DE06, DE09.05 PD14, PE14, DD14, DE14, DE15, DE15V(II) DEG15HC.20(II), DEG15MC.20(II) DEG15VC.20(II), DE18M(II), DEG18MC.20(II) DE19, DEG19C.20 Manufacture Module Model / Series TSMC TS-150C2 CIGSw Universal Solar UNI4xx-144BMH-DG UNI5xx-144BMH-DG UNIxxx-108M-BB UNIxxx-120M-BB UNIxxx-120MH Upsolar UP-MxxxP, UP-MxxxM(-B) URECO D7Kxxx(H7A/H8A), D7Mxxx(H7A/H8A) FAKxxx(C8G/E8G), FAMxxxE7G-BB FAMxxxE8G(-BB), FBKxxxM8G F6MxxxE7G-BB FBMxxxMFG-BB Vikram Eldora, Somera, Ultima 35(;26960'+7$$$ 35(;26960'+7$$$ Vina VNS-72M1-5-xxxW-1.5, VNS-72M3-5-xxxW-1.5, VNS-144M1-5-xxxW-1.5, VNS-144M3-5-xxxW-1.5, VNS-120M3-5-xxxW-1.0 VSUN VSUNxxx-60M-BB, VSUNxxx-72MH VSUN4xx-144BMH VSUN4xx-144BMH-DG VSUN5xx-144BMH-DG VSUNxxx-108M-BB VSUNxxx-120M-BB VSUNxxx-120BMH VSUNxxx-132BMH VSUNxxx-108BMH Waaree Ahnay Series Bi-33 Arka Series WSMDi 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS SM SOLAR MOUNT SYSTEM CERTIFICATION PAGE 34COMPATIBLE MODULES Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the SOLARMOUNT system. ȫ8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID ȫ7KHIUDPHSURʳOHPXVWQRWKDYHDQ\IHDWXUHWKDWPLJKWLQWHUIHUHZLWKWKHERQGLQJGHYLFHVWKDWDUHLQWHJUDWHGLQWRWKHUDFNLQJV\VWHP • Use with a maximum over current protection device OCPD of 30A • /LVWHGPRGHOVFDQEHXVHGWRDFKLHYHD&ODVV$ʳUHV\VWHPUDWLQJIRUVWHHSVORSHDSSOLFDWLRQV6HHSDJH Manufacture Module Model / Series Winaico :67 :636HULHV Yingli <*( </06HULHV Yotta Energy YSM-B450-1 ZNShine =;06HULHV=;01+ =;01+/'' =;06+6HULHV 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS Descriptive Report and Test Results The reader is responsible for any liability arising from actions taken in interpreting or applying the results presented in this report. This report shall not be reproduced except in full, without written approval from CSA Group Testing & Certification Inc. The results of this report only relate to those items tested. 34 Bunsen, Irvine, CA, U.S.A. 92618 Telephone: 949.733.4300 1.800.463.6727 Fax: 949.733.4320 www.csagroup.org DQD 507.10 Rev 2022-08-05 © 2022 CSA Group. All rights reserved. 34 Bunsen Irvine CA U S A 92618CS MASTER CONTRACT: 266909 REPORT: 70131735 PROJECT: 80136577 Edition 1: September 20, 2017; Project 70131735 - Irvine Prepared By: Michael Hoffnagle Authorized By: Michael Hoffnagle Edition 19:July 29, 2022; Project 80129816 - Irvine Prepared By: Michael Hoffnagle Authorized By: Michael Hoffnagle Edition 20:August 12, 2022; Project 80136577 - Irvine Prepared By: Michael Hoffnagle Authorized By: Michael Hoffnagle Report pages reissued Contents: Certificate of Compliance - Pages 1 to 6 Supplement to Certificate of Compliance - Pages 1 to 3 Description and Tests - Pages 1 to 27 Att1 Installation Manual SM–Pages 1 to 38 Att2 Schematics SM/ULA–Pages 1 to 72 Att3 Installation Manual ULA–Pages 1 to 22 Att4 RM5_Installation Guide - 1 to 19 Att5 RMDT_Installation Guide - 1 to 20 Att6 RM series schematics –1 to 32 Att7 Installation Manual, GFT Shared Rail –Pages 1 to 41 Att8 Installation Manual, GFT 4-Rail –Pages 1 to 40 Att9 GFT Schematics –Pages 1 to 45 Att10 NXT Horizon Installation Manual –Pages 1 to 23 Att11 Schematics NXT Horizon –Pages 1 to 27 PRODUCTS CLASS - C531302 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems CLASS - C531382 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems - Certified to US Standards MASTER CONTRACT:266909 REPORT:70131735 PROJECT:80136577 Page No: 2 Date Issued:August 12, 2022 DQD 507.10 Rev 2022-08-05 © 2022 CSA Group. All rights reserved. Models:SM -SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV racking system that is installed parallel to the roof in landscape or portrait orientations. ULA -Unirac Large Array is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. Solarmount The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. The system is secured to the roof with the L-Foot components through the roofing material to building structure. Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end clamps. The modules are bonded to the racking system with the stainless-steel bonding mid clamps with piercing points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A with Type 1, 2, 3 (with metallic frame), 4 (with trim), 5 (with trim), 10(with metallic frame), 19, 22, 25, 29, or 30 for steep slope. Tested at 5” interstitial gap which allows installation at any stand-off height. The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used during the certification testing for the current edition of the project report. The system may employ optimizers/micro-inverters and used for grounding when installed per installation instructions. UL 2703 Mechanical Load ratings: Module Area up to 22.2 sq ft Downward Design Load (lb/ft²)113.5 Upward Design Load (lb/ft²)50.7 Down-Slope Load (lb/ft²)16.13 Module Area up to 27.12 sq ft Downward Design Load (lb/ft²)33.9 Upward Design Load (lb/ft²)33.9 Down-Slope Load (lb/ft²)16.5 Test Loads: Module Area up to 22.2 sq ft Downward Load (lb/ft²)170.20 Upward Load (lb/ft²)76.07 Down-Slope Load (lb/ft²)24.2 Module Area up to 27.12 sq ft Downward Design Load (lb/ft²)50.85 Upward Design Load (lb/ft²)50.85 Down-Slope Load (lb/ft²)24.75 SM SOLARMOUNT 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS MASTER CONTRACT:266909 REPORT:70131735 PROJECT:80136577 Page No: 6 Date Issued:August 12, 2022 DQD 507.10 Rev 2022-08-05 © 2022 CSA Group. All rights reserved. SM and ULA markings The following markings appear on the rail by adhesive label: 1.Submitter’s name and/or CSA Master Contract number “266909”; 2. Model designation; 3. Manufacturing date; 4. System fire class rating/designation of information location in Installation Manual; 5. Design load rating/designation of information location in Installation Manual; The following markings appear on the Mid clamp by stamping: 1.Submitter’s name and/or CSA Master Contract number “266909”; 2. CSA mark 3. Mil ID for factory location Nameplate adhesive label material approval information: SATO AMERICA INC, SF401 DuraMark Polyester, MH48415 - Printing Materials –Component, UL 969- Marking and Labeling Systems RM 5 South and RM DT markings The following markings appear on the ballast bay by permanent stamping: 1.Submitter’s name and/or CSA Master Contract number “266909”; 2. Model designation; 3. Manufacturing date; 4. System fire class rating/designation of information location in Installation Manual; 5. Design load rating/designation of information location in Installation Manual; Nameplate adhesive label material approval information: Markings applied via permanent stamping to bay. MASTER CONTRACT:266909 REPORT:70131735 PROJECT:80136577 Page No: 9 Date Issued:August 12, 2022 DQD 507.10 Rev 2022-08-05 © 2022 CSA Group. All rights reserved. 1. The system does not employ a maximum number of modules that can be installed per system. 2. Module Orientation: a. SM & ULA - Portrait or Landscape b. RM5 & DT –Landscape c. GFT –Portrait d. NXT Horizon - Portrait or Landscape 3. The system was evaluated for use with modules up to: a. SM & ULA –27.12 sq ft b. RM5 & DT –27.76 sq ft c. GFT - Portrait - 27.12 sq ft d. NXT Horizon –27.76 sq ft 4. See Table 1 for customer supplied information for SM 5. See Table 2 for customer supplied information for ULA 6. See Table 3 for customer supplied information for RM 7. See Table 4 for customer supplied information for GFT 8. See Table 5 for customer supplied information for NXT Horizon 9. See the attached installation manual for each model installation instructions, and system drawings. The critical components identified below may be formed at other locations and shipped directly to the construction site provided they are made with the material/coatings identified and conform to the physical dimensions described and shown in their respective illustrations. Physical specimens may not be present at the location where the CSA mark is applied. Location of markings can be found in the Marking section of this report. Table 1 MODULE RACKING SYSTEM TYPE/S Model SM Module Fire Type.............................:Class A with Type 1, 2, 3 (with metallic frame), 4 (with trim), 5 (with trim), 10 (with metallic frame), 19, 22, 25, 29, or 30 for steep slope. Tested at 5” interstitial gap, the rating obtained for a 5-inch (127 mm) gap can be used for any other gaps allowed by the mounting instructions, per section 15 of UL 2703 Max branch circuit overcurrent- protection device (A) 30 IDENTIFICATION OF COMPONENTS AND MATERIALS End Clamp........................................:M101XX Rev. H Extruded Aluminum : 6005A-T61, 6351-T5, 6061-T6, 6005-T5, 6105-T5 End Clamp Assembly.......................:M500XX Rev. C, (M50060 –M50071) Extruded Aluminum : 6005A-T61, 6351-T5, 6061-T6, 6005-T5, 6105-T5 Bonding Mid Clamp.........................:M6065X, Rev A and M6065X, Rev F 300 Series Stainless Steel SM SM SM Model 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS MASTER CONTRACT:266909 REPORT:70131735 PROJECT:80136577 Page No: 10 Date Issued:August 12, 2022 DQD 507.10 Rev 2022-08-05 © 2022 CSA Group. All rights reserved. Mid-Clamp Assembly.......................:M500XX Rev. E, (M50077 –M50082) Extruded Aluminum: 6005A-T61, 6351-T5, 6061-T6, 6005-T5, 6105-T5 End-Clamp Assembly.......................:M60630 Rev. F Extruded Aluminum per ASTM B221-08: 6005A-T61, 6061-T6 and 18-8 Stainless Steel or 316 Stainless Steel Mid-Clamp Assembly.......................:M60640 Rev. B –Mill finish or SKU 302030M M60645 Rev. B –Anodized finish or SKU 302030D Extruded Aluminum per ASTM B221-08: 6005A-T6, 6061-T6, or 6351-T5 and 300 Series Stainless Steel and 316 Stainless Steel End-Clamp Assembly.......................:P30602125 Rev. D, Rev. E Extruded Aluminum per ASTM B221-08: 6005A-T61 or 6061-T6, 6063-T6 and 300 Series Stainless Steel. Mid-Clamp Assembly.......................:P30601225 Rev. C, Rev. D Extruded Aluminum per ASTM B221-08: 6063-T6 and 300 Series Stainless Steel. T-Bolt Serrated.................................:M3020X Rev. A, Rev. D, Rev. D3, Rev. E 300 Series Stainless Steel T-Bolt Non-Serrated........................:M3018X, Rev. G 300 Series Stainless Steel Suitable for use ONLY on mil-finish rails, such as: • M10001 (SM1 rail, item 008A) • M10154-1 (SM2 rail, item 008B) SM Rail.............................................:M10001, Rev D Extruded Aluminum: 6005A-T61, 6351-T5, 6061-T6, 6005-T5, 6105-T5; Mil-Finish SM Rail.............................................:M10154, Rev D Extruded Aluminum: 6005A-T61, 6351-T5, 6061-T6, 6005-T5, 6105-T5; Finish per table: -1 = Mil; as fabricated M12 -2 = Clear; Anodize Type II A-21 clear -3 = Black, Anodize Type II A-24 black SM Heavy Duty Rail........................:M10XXX, Rev D Extruded Aluminum per ASTM B221-08: 6005A-T61, 6351-T5, 6061-T6, 6005-T5 and 6105-T5; Finish per table: MASTER CONTRACT:266909 REPORT:70131735 PROJECT:80136577 Page No: 11 Date Issued:August 12, 2022 DQD 507.10 Rev 2022-08-05 © 2022 CSA Group. All rights reserved. SM Light Rail...................................:M101XX, Rev A Extruded Aluminum per ASTM B221-08: 6005A-T61 and 6061- T6; Finish per table: Splice Bar, 4”....................................:M103XX, Rev. B Extruded Aluminum : 6005A-T61, 6351-T5, 6061-T6, 6005-T5, 6105-T5 BND Splice Bar Pro Series SM........:P28205001, Rev. B Material is extruded aluminum per ASTM B221-08:6005A-T61, 6351-T5, 6061-T6, 6005-T5 and 6105-T5; Finish per table: Serrated L-Foot.................................:M10175, Rev G Extruded Aluminum : 6005A-T61, 6351-T5, 6061-T6 P28405002-002, Rev. C Finish per table: EcoFasten Solar 004050X Aluminum: 6000 Series, Finish: X= M –Mill Finish Aluminum D –Anodize Black Type 2, Class 2 per AAMA 611-12 P28503006, Rev. E COMP ASSEMBLY FLASHLOC Cast Aluminum, A380 Mill or Black finish, see drawings P28503025, Rev. B ASSEMBLY FLASHLOC DTD Cast Aluminum, A380 Mill or Black finish, see drawings 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS MASTER CONTRACT:266909 REPORT:70131735 PROJECT:80136577 Page No: 12 Date Issued:August 12, 2022 DQD 507.10 Rev 2022-08-05 © 2022 CSA Group. All rights reserved. Serrated nut.......................................:EcoFasten Solar, N-FL 375-16X335 UNI 18-8 Stainless Steel or 304 Stainless Steel Nut, Flange Serrated.........................:M30211 Stainless Steel, Black Oxide Nut, Flange Serrated.........................:M30380 300 Series Stainless Steel T-bolt, Serrated.................................:M31156 300 Series Stainless Steel Washer, Flat, RET............................:M31160 PVC Plastic Washer NEOP...................................:M31161 Neoprene Screw, Self Drill...............................:M31162 300 Series Stainless Steel Nut, Keps 0.25..................................:M31163 300 Series Stainless Steel Nylon-Insert Lock Nut, 0.25-20 ......:M30360 316 Stainless Steel K-Lock Nut, 0.25-20 .......................:M31159 18-8 Stainless Steel Nut, Flange Serrated.........................:M31184 300 Series Stainless Steel Tri Drive Nut serrated M38018 18-8 Stainless Steel Micro-inverter T-Bolt.......................:M50085 300 Series Stainless Steel MLPE Mount....................................:M51538 Rev. C Extruded Aluminum with Stainless Steel Bond Pin & Serrated Flange Nut ETL file 5003705 SM Trim ...........................................:M110XX Rev. C Extruded Aluminum per ASTM B221-08: 6005A-T61, 6351-T5, 6061-T6, 6005-T5 and 6105-T5; Finish per table : Micro-Inverter ..................................:Enphase, M215, M250, IQ6 or IQ6+ Aluminum mounting bracket attached to electronics enclosure MASTER CONTRACT:266909 REPORT:70131735 PROJECT:80136577 Page No: 13 Date Issued:August 12, 2022 DQD 507.10 Rev 2022-08-05 © 2022 CSA Group. All rights reserved. Optimizer..........................................:Solar Edge, P300, P320, P400, or P405, P600, P700, P730, P800p or P800s Aluminum mounting bracket attached to electronics enclosure. N-S Clip............................................:M60013 8AWG or Equivalent solid copper wire, 300 stainless steel spring force clips Ground lug........................................:Burndy WEEB-LUG-6.7 Tin Plated Copper, Stainless Steel Bonding Insert UL467 Listed Intertek 3098177 Ground lug........................................:Ilsco Lay in Lug GBL-4DBT Tin-plated copper with stainless steel torque screw; Ground wire 4-14 AWG UL467 Listed UL File E34440 Ground lug........................................:Ilsco SGB-4 lug 6061 Aluminum, Tin Plated UL467 Listed UL File E34440 Label.................................................:SATO AMERICA INC, SF401 DuraMark Polyester, MH48415 - Printing Materials –Component, UL 969-Marking and Labeling Systems Installation Manual...........................:2022JUL21 SM Installation Guide Table 2 MODULE RACKING SYSTEM TYPE/S Model ULA using SM Platform ULA Front Cap.................................:M50400 (Assembly of Doghouse and Slider) 6105-T5 Aluminum ULA Rear Cap..................................:M50420 (Assembly of Doghouse and Slider) 6105-T5 Aluminum ULA Aluminum 2 Inch Doghouse ...:M10920, Rev. C Material is extruded aluminum per ASTM B221-08:6005A-T61, 6351-T5, 6061-T6, 6005-T5 and 6105-T5; 2022JUL21 SM Installation GuideInstallation Manual ...........................: 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS Th e r i g h t w a y t o a t t a c h a l m o s t a n y t h i n g t o m e t a l r o o f s ! SolarFoot Features: Manufactured in the U.S.A. from certified raw material Fabricated in our own ISO 9001:2015 certified factory All aluminum and stainless components 25yr limited warranty Compatible with all commercial L-Foot products on the market Factory applied 40-year isobutylene/ isoprene crosslink polymer sealant for reliable weathertightness Sealant reservoir to prevent over- compression of sealant Load-to-failure tested Normal to Seam by a nationally accredited laboratory on numerous metal roof materials and substrates Four points of attachment into structure or deck with tested holding strength for engineered applications Integrated M8-1.25x17mm stud and M8-1.25 stainless steel hex flange nut included 88 8 - 8 2 5 - 3 4 3 2 | w w w . S - 5 . c o m | Introducing the new SolarFoot™ for exposed fastener metal roofing with the strength, testing, quality, and time-proven integrity you expect from S-5!. The SolarFoot provides an ideal mounting platform to attach the L-Foot (not included) of a rail-mounted PV system to the roof. This solution is The Right Way to secure rail-mounted solar systems to exposed fastener metal such as AG-Panel or R-Panel. NEW PRODUCT SolarFoot™SolarFootTM0RXQWLQJIRU([SRVHG)DVWHQHU5RR¿QJ Fastener Selection To source fasteners for your projects, contact S-5! When other brands claim to be “just as good as S-5!”, tell them to PROVE IT. The SolarFoot is a simple, cost-effective pedestal for L-Foot (not included) attachment of rail-mounted solar PV. The unique design is compatible with all rail producer L-Foot components. The new SolarFoot assembly ensures a durable weathertight solution for the life of the roof. Special factory applied butyl co-polymeric sealant contained in a reservoir is The Right Way, allowing a water-tested seal. Stainless integrated stud and hex flange lock-nut secure the L-Foot into position. A low center of gravity reduces the moment arm commonly associated with L-Foot attachments. Direct attachment of the SolarFoot to the structural member or deck provides unparalleled holding strength. *Fasteners sold separately. Fastener type varies with substrate. Contact S-5! on how to purchase fasteners and obtain our test results. L-Foot also sold separately. Distributed by: SolarFoot Advantages: Exposed fastener mounting platform for solar arrays attached via L-Foot and Rails Weatherproof attachment to exposed fastener roofing Butyl sealant reservoir provides long-term waterproof seal M8-1.25x17mm stud with M8 hex flange nut for attachment of all popular L-Foot/rail combinations Tool: 13 mm Hex Socket or ½” Hex Socket Tool Required: Electric screw gun with hex drive socket for self- tapping screws. Low Center of Gravity reduces moment arm commonly associated with L-Foot/Rail solar mounting scenarios Attaches directly to structure or deck for optimal holding strength S-5! Recommended substrate- specific (e.g. steel purlin, wood 2x4, OSB, etc.) fasteners provide excellent waterproofing and pull- out strength Fastener through-hole locations comply with NDS (National Design Specification)for Wood Construction S-5!® Warning! Please use this product responsibly! The independent lab test data found at www.S-5.com can be used for load-critical designs and applications. Products are protected by multiple U.S. and foreign patents. For published data regarding holding strength, fastener torque, patents, and trademarks, visit the S-5! website at www.S-5.com. Copyright 2017, Metal Roof Innovations, Ltd. S-5! products are patent protected. Copyright 2017, Metal Roof Innovations, Ltd. Version 102017 LQ LQ LQ LQ LQ LQ LQ LQ [ PP LQ LQ  PP LQ  LQ LQ LQ )DFWRU\$SSOLHG %XW\O6HDODQW 06WDLQOHVV6WHHO 7KUHDGHG6WXG Metal to Metal: 1/4-14 Self Drilling Screw 1-1/2" to 2-1/2" Metal to Wood: 1/4-14 Type 17 AB Milled Point 1-1/2" to 2-1/2"