Loading...
HomeMy WebLinkAboutROOF JOIST - 23-00790 - 222 W 2nd N - Patio CoverDesign Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)531 @ 7' 8 1/4"10455 (5.50")Passed (5%)--1.0 D + 1.0 S (All Spans) Shear (lbs)314 @ 7' 1/16"2277 Passed (14%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)636 @ 3' 11 3/16"1950 Passed (33%)1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in)0.066 @ 4' 1/8"0.371 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.093 @ 4'0.494 Passed (L/953)--1.0 D + 1.0 S (Alt Spans) System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 2/12 •Deflection criteria: LL (L/240) and TL (L/180). •Overhang deflection criteria: LL (2L/240) and TL (2L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Factored Accessories 1 - Beveled Plate - DF 5.50"5.50"1.50"118 277 395 Blocking 2 - Beveled Plate - DF 5.50"5.50"1.50"161 370 531 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)9' 4" o/c Bottom Edge (Lu)9' 4" o/c Dead Snow Vertical Load Location (Side)Spacing (0.90)(1.15)Comments 1 - Uniform (PSF)0 to 9' 2"24"15.0 35.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 9' 4 7/16" MEMBER REPORT PASSED Level, Roof: Joist 2 piece(s) 2 x 6 DF No.2 @ 24" OC ForteWEB Software Operator Job Notes 11/3/2023 4:35:10 PM UTCGlen Hansen Builders First Source (208) 656-9591 Glen.hansen@bldr.com ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 File Name: porch Page 1 / 1