HomeMy WebLinkAboutPLAN - 23-00802 - 35 S Hidden Valley Rd - Solar PanelsUtahEnergySavers.com
ESSolar.net
Layton, UT 801-614-0606
WILCKEN RESIDENCE
35 S HIDDEN VALLEY RD
REXBURG, IDAHO 83440
Sheet 1 of 6
PLANT LOCATION
Scale
NTS
PLANT LOCATION:
WILCKEN RESIDENCE
35 S HIDDEN VALLEY RD
REXBURG, IDAHO 83440
SOLAR EDGE SE7600H-US INVERTER
25 HANWHA Q.PEAK BLK-G4.1 295
PV PANELS
SOLAR EDGE SE7600HUB-US INVERTER
31 SOLARIA POWERXT-400R-PM PANELS
SOLAR EDGE SE5000H-US INVERTER
17 LG LG335N1C-A5 335 PV PANELS
(2) SOLAR EDGE SE7600H-US INVERTER
47 HANWHA Q.PEAK DUO BLK-G5 310
PV PANELS
SOLAR EDGE SE7600H-US INVERTER
25 JA JAM60S03-310/PR PV PANELS
SOLAR EDGE SE3800H-US INVERTER
14 PANASONIC VBHN320KA03 320
PV PANELS
SOLAR EDGE SE7600HUB-US INVERTER
25 S ENERGY SL40-60MBI-360V PANELS
REVISION 1:
ADDITION TO EXISTING SOLAR SYSTEM
PLAN BY: BRYCE PETERSON
SOLAR EDGE SE7600H-US INVERTER
25 VIKRAM SOMERA VSMHBB.60.365
TEXT
UtahEnergySavers.com
ESSolar.net
Layton, UT 801-614-0606
INSTALL SITE
Scale
NTSLIMITS OF CONSTRUCTION
SOLADECK
JUNCTION
BOX (S)
EXISTING COMBINER PANEL
(LOCATED NEXT TO SERVICE)
EXISTING 200A SERVICE
ENTRANCE PANELBOARD
Sheet 2 of 6
GENERAL NOTES:
ALL CONSTRUCTION / INSTALLATION SHALL COMPLY WITH:
2017 NATIONAL ELECTRICAL CODE (NEC)
2018 INTERNATIONAL FIRE CODE (IFC)
2018 INTERNATIONAL BUILDING CODE (IBC)
2018 INTERNATIONAL RESIDENTIAL CODE (IRC)
ALL DIMENSIONS SHOWN ARE APPROXIMATE
UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PV SYSTEM
COMPONENTS LOCATED AT SERVICE ENTRANCE
ALL CONDUITS ON ROOF SHALL BE A MINIMUM OF ½” OFF ROOF
CONSTRUCTION LIMITS: ALL IMPROVEMENTS AND ACCESS
SHALL OCCUR WITHIN PLANT PROPERTY LINES
PHOTOVOLTAIC SYSTEM
COMBINER PANEL 100A, 120/240
VAC LOAD CENTER
DEDICATED PHOTOVOLTAIC SYSTEM AC DISCONNECT
ESS BATTERY
(LOCATED INSIDE GARAGE ON SIDEWALL)
DEDICATED BATTERY SYSTEM AC
DISCONNECT
(LOCATED IN SIGHT OF BATTERY)
EXISTING DEDICATED BATTERY
SYSTEM UTILITY STOP DISCONNECT
(LOCATED NEXT TO SERVICE)
NEW 125A SUBPANEL
(LOCATED IN SIGHT OF BATTERY)
Portrait = 4 panels per 14’ rail
Landscape = 2 panels per 14” rail
Portrait = 1 rail to 2 panels (360W/400W = 2 rails to 3 panels)
Landscape = 1 rail to 1 panel
Splices = 2 for every consecutive 4 panels portrait (3 panels for
360W/400W)/ 2 panels landscape
End Clamps = 2 on every end
Mid Clamps = 2 on every joint between panel
EXISTING 200A INTERIOR
LOADS PANEL LOCATED IN
BASEMENT
DEDICATED PHOTOVOLTAIC
SYSTEM AC DISCONNECT
(LOCATED NEXT TO SERVICE)
SOLADECK JUNCTION BOX (S)
ONE PER ARRAY
APPROX. 40' DC RUN
(IN ATTIC WHERE
AVAILABLE)
SOLADECK JUNCTION BOX
(S) ONE PER ARRAY
B
DEDICATED PHOTOVOLTAIC
SYSTEM AC DISCONNECT
(LOCATED NEXT TO SERVICE)
PV METER SOCKET
(LOCATED NEXT TO SERVICE)
ESS BATTERY
(LOCATED INSIDE GARAGE ON SIDEWALL IN
THE FRONT 10 FEET OF GARAGE)
TRENCH
TRENCH
EXISTING SOLAR ARRAYS
(SHOWN IN BLUE)
WILCKEN RESIDENCE
35 S HIDDEN VALLEY RD
REXBURG, IDAHO 83440
(6)#14 AWG CU
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR
UtahEnergySavers.com
ESSolar.net
Layton, UT 801-614-0606
Scale
NTS Sheet 3 of 6
4 #10 THWN-2 CU PV WIRE1 #10 THWN-2 CU GND3/4" EMT CONDUITSOLADECK JUNCTION BOX TRANSITION BOX
AC ONE LINE
DIAGRAM
OTHER
LOADS
40A/2P
60A/2P VISIBLY OPEN
DISCONNECT (LOCATED
WITHIN 3’ OF SERVICE)
30A/2P
40A/2P
NEW 125A BACKUP LOADS
SUBPANEL (LOCATED IN INTERIOR)
NO SINGLE LOAD LARGER THAN 36A
OR 8.64KVA (NEC 710.15)
125A SUBPANEL
CT
ETHERNET LINE TO HOME
NETWORK
A*
D*
E*
F*
A*-EXISTING MAIN SERVICE (SC816D200C)
B*-30A/2P DISCONNECT (EATON DG221URB)
C*-SONNEN CORE ESS (SONNENCORE20KWH)
D*-NEW SUBPANEL (EATON BR816L125RP)
E*-NEW SUBPANEL (EATON BR816L125RP)
F*-60A/2P DISCONNECT (EATON DG222URB)
G*-EXISTING ENPHASE COMBINER
H*-HEAT/SMOKE DETECTOR (BRK SA520B) LOCATED IN CEILING ABOVE ESS
(2)#10 AWG CU
(1)#10 AWG NEUTRAL CU
(1)#10 AWG EGC CU
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR
(2)#8 AWG CU
(1)#8 AWG NEUTRAL CU
(1)#8 AWG EGC CU
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR
AC CIRCUITS CONTINUE
TO EXISTING
MICROINVERTERS
NEW
INTERCONNECTED
HEAT OR SMOKE
DETECTOR
H*
(2)#8 AWG CU
(1)#8 AWG NEUTRAL CU
(1)#8 AWG EGC CU
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR
(2)#8 AWG CU
(1)#8 AWG NEUTRAL CU
(1)#8 AWG EGC CU
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR
EXTERIOR LOCATED
LESS THAN 3 FT FROM
MAIN
200A MAIN
C*
20 KWH BATTERY
SONNEN CORE ESS
4.8 KW
INVERTER
40A AUTOMATIC
TRANSFER SWITCH
LOCKABLE
DISCONNECT
EXISTING
LOCKABLE 30A/2P
VISIBLY OPEN
DISCONNECT B*
C*-200A SUB PANEL (EATON BRP08B200RF)
C*-200A SUB PANEL (EATON BRP12L200R)
EXTERIOR SUBPANEL SIZES:
BRP08B200RF = 8 BREAKER SLOTS
BRP12L200R = 12 BREAKER SLOTS
B*-NEW 125A SUBPANEL (EATON BR816L125RP)
*WE WILL BE ADDING ONE 125A BREAKER TO THE MAIN SERVICE PANEL TO PROTECT THE EXISTING HOUSE FEEDER WIRES IN COMPLIANCE WITH NEC 705.12(B)(2)(1)(B)PV METERB*- PV METER BOX
E*-30A/2P DISCONNECT (EATON DG221URB)
200A/2P
40A/2P
OTHER
LOADS
(2)#6 AWG CU
(1)#6 AWG NEUTRAL CU
(1)#6 AWG EGC CU
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR
(2)#8 AWG CU
(1)#8 AWG NEUTRAL CU
(1)#8 AWG EGC CU
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR
(2)#10 AWG CU
(1)#10 AWG NEUTRAL CU
(1)#10 AWG EGC CU
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR
*WE WILL BE ADDING ONE 125A BREAKER
TO THE MAIN SERVICE PANEL TO PROTECT
THE EXISTING HOUSE FEEDER WIRES IN
COMPLIANCE WITH NEC 705.12(B)(2)(1)(B)
IN GARAGE
(UNLESS OTHERWISE SPECIFIED)
(2)#14 AWG CU (24V EMERGENCY STOP
CONTACT)
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR
(2)3/0 AWG CU / 4/0 AWG AL
(1)3/0 AWG NEUTRAL CU / 4/0 AWG AL
(1)#6 AWG EGC CU / #4 AWG AL
2” EMT MIN. W/ THWN-2 /SER CABLE
(2)1/0 AWG CU / 2/0 AWG AL
(1)1/0 AWG NEUTRAL CU / 2/0 AWG AL
(1)#6 AWG EGC CU / # 4 AWG AL
1 ½ ” EMT MIN. W/ THWN-2 OUTDOOR /
SER CABLE INDOOR
(2)#1 AWG CU / 1/0 AWG AL
(1)#1 AWG NEUTRAL CU / 1/0 AWG AL
(1)#6 AWG EGC CU / #4 AWG AL
1 ½ ” EMT MIN. W/ THWN-2 OUTDOOR /
SER CABLE INDOOR
(2)#2 AWG CU / #2 AWG AL
(1)#2 AWG NEUTRAL CU / #2 AWG AL
(1)#8 AWG EGC CU / #6 AWG AL
1 ½ ” EMT MIN. W/ THWN-2 OUTDOOR /
SER CABLE INDOOR
OGDEN WIRE SIZES NEED TO BE
CHANGED TO:
(2)#8 AWG CU
(1)#8 AWG NEUTRAL CU
(1)#10 AWG EGC CU
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR
(2)#14 AWG CU (24V EMERGENCY STOP
CONTACT)
¾” EMT MIN. W/ THWN-2 OUTDOOR / NM
CABLE INDOOR OR SPEAKER WIRE OR
SPRINKLER WIRE
2X 20A/2P
B*
10A/2P
EXISTING COMBINER
WILCKEN RESIDENCE
35 S HIDDEN VALLEY RD
REXBURG, IDAHO 83440
UtahEnergySavers.com
ESSolar.net
Layton, UT 801-614-0606
SIGNAGE
Scale
NTS
1 DUAL INPUT SOURCE
SECOND SOURCE IS SOLAR PV SYSTEM
ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND NOT HAND-WRITTEN. NEC 110.21(B)
SIGN LOCATED AT POINT OF INTERCONNECTION.
NEC 690.56(B) AND 705.10 AND 712.10
2 WARNING:SOLAR POWER SOURCE
OUTPUT CONNECTION,
DO NOT RELOCATE
THIS OVERCURRENT DEVICE
SIGN LOCATED NEXT TO SOLAR BACKFEED BREAKERS AT SERVICE PANEL.
IF BREAKER FEED AND UTILIZING THE 120% RULE NEC 705.12(B)(2)(3)(b)
3 RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
SIGN LOCATED NEXT TO THE SOLAR AC OR DC DISCONNECT THAT
ACTIVATES RAPID SHUTDOWN. NEC 690.56 (C) (3) OR NEXT TO MAIN
SERVICE DISCONNECT OR NEXT TO A RSD RELAY SIGNAL BUTTON
THE MARKINGS SHALL BE REFLECTIVE WHITE ON RED BACKGROUND
5 PHOTOVOLTAIC POWER SOURCE
THIS SIGN IS LOCATED ON THE OUTSIDE OF ANY CONDUITS, ENCLOSURES, OR MC CABLE THAT CONTAINS DC CIRCUITS.
The markings shall be reflective and be provided at every enclosure, every 10’ along conduit or MC cable, and at each side of where the
conduit or cable passes through a wall, floor, or any other partition. NEC 690.31(G)(3-4) and IFC 605.11.1.2
8
4 PHOTOVOLTAIC ARRAY
DC DISCONNECT SWITCH
MAX SYSTEM VOLTAGE= 480 VDC
MAX CIRCUIT CURRENT= 15 ADC
MAX CURRENT FOR POWER
OPTIMISERS= 15 ADC
THIS SIGN IS LOCATED ON THE OUTSIDE OF EACH DC DISCONNECT.
NEC 690.53 and 690.13(B)
7
PV SYSTEM BACKFEEDING
THROUGH THIS PANEL
AC OUTPUT CURRENT= 32 AAC
AC VOLTAGE=240 VAC
THIS SIGN IS LOCATED AT THE BACKFEED PANEL BOARD
NEC 690.54
Sheet 4 of 6
11PHOTOVOLTAIC SYSTEM
DEDICATED KWH METER
THIS SIGN IS LOCATED AT THE DEDICATED
KWH METER
6
NOTICE:
PV SYSTEM COMBINER PANEL
DO NOT ADD LOADS TO THIS PANEL
THIS SIGN IS LOCATED AT THE COMBINER PANEL
PHOTOVOLTAIC SYSTEM
AC DISCONNECT
THIS SIGN IS LOCATED AT THE AC PV SYSTEM DISCONNECT
690.13 (B)
THIS SIGN IS LOCATED ON OR WITHIN 3’ FEET OF THE
SERVICE METER PANELBOARD AND ON ANY AC DISCONNECT
SWITCH ON THE OUTSIDE OF THE BUILDINGS NEC
690.56(C)(1) / IFC 1204.5.1
9
SE3000H-US 12.5
SE3800H-US 16
SE5000H-US 21
SE6000H-US 25
SE7600H-US 32
SE10000H-US 42
SE11400A-US 47.5
Ansi z535.4 color
specific
ENERGY STORAGE SYSTEM
DISCONNECT
NOMINAL ESS AC VOLTAGE=_240_VAC
MAXIMUM ESS DC VOLTAGE=_204_VDC
SIGN LOCATED AT ENERGY STORAGE SYSTEM DISCONNECTS
NEC 706.15(C)
10
9
CAUTION: MULTIPLE SOURCES OF POWER
POWER TO THIS SERVICE IS ALSO SUPPLIED FROM A PV SYSTEM
CONNECTED TO THE AC SERVICE PANEL.
LITHIUM BATTERY IS LOCATED IN GARAGE (SIDEWALL)
MICROINVERTERS ARE LOCATED AT EACH MODULE
BATTERY LIGHTS WILL BE OFF WHEN EMERGENCY STOP ACTIVE
THIS DIRECTORY LOCATED AT POINTS OF INTERCONNECTION.
NEC 690.56(B) AND 705.10 AND 706.21 AND 710.10 AND 712.10
ALSO PER UTILITY REQUIREMENTS
WILCKEN RESIDENCE
35 S HIDDEN VALLEY RD
REXBURG, IDAHO 83440
UtahEnergySavers.com
ESSolar.net
Layton, UT 801-614-0606
PLACARDS
Scale
NTS
ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND NOT HAND-WRITTEN. NEC 110.21(B)
Sheet 5 of 6
11
PARALLEL
GENERATION ON
SITE
THIS PLACARD IS LOCATED NEXT TO METER SOCKET. 2”X4”
ENGRAVED METAL OR RED AND WHITE HARD PLASTIC ⅜” OR LARGER
LETTERS
MANUAL
DISCONNECT
FOR BATTERY
THIS PLACARD IS LOCATED AT THE AC ESS SYSTEM
DISCONNECT. 2”X4” ENGRAVED METAL OR RED AND WHITE
HARD PLASTIC ⅜” OR LARGER LETTERS
12
N
MANUAL
DISCONNECT
FOR PARALLEL
GENERATION
THIS PLACARD IS LOCATED AT THE AC PV SYSTEM
DISCONNECT. 2”X4” ENGRAVED METAL OR RED AND WHITE
HARD PLASTIC ⅜” OR LARGER LETTERS
13
MANUAL
DISCONNECT
FOR PARALLEL
GENERATION
AND BATTERY
THIS PLACARD IS LOCATED AT THE AC ESS SYSTEM
DISCONNECT. 2”X4” ENGRAVED METAL OR RED AND WHITE
HARD PLASTIC ⅜” OR LARGER LETTERS
12
WARNING:
MULTIPLE SOURCES OF POWER. A
PV SYSTEM IS PRESENT.
DISCONNECT ALL POWER SOURCES
BEFORE SERVICING.
FOR ST GEORGE POWER
WILCKEN RESIDENCE
35 S HIDDEN VALLEY RD
REXBURG, IDAHO 83440
UtahEnergySavers.com
ESSolar.net
Layton, UT 801-614-0606
Scale
NTS
SIGNAGE LOCATION
Sheet 6 of 6
*5
*5
*5
*5
*5
*5
*5
*1,*9
EXISTING 200A
MAIN SERVICE PANEL
TRANSITION BOX SOLADECK
JUNCTION BOXES
IN ATTIC
(EXTERIOR *7)
(NEXT TO
BREAKER
*2,*6)*11,
*1,*8,*13
* NOT REFLECTIVE OF
ACTUAL EQUIPMENT
LOCATION
NEW
SUBPANEL
AC
DISCONNECT SONNEN ESS
IN GARAGE
*1, *2, *6,
*10
*3,*8, *13
EXISTING
LOCKABLE
VISIBLY OPEN
DISCONNECT
*3, *10, *12
* FOR SIGNAGE AND
PLACARDS SEE PAGES 7 AND
8
*ONLY APPLICABLE STICKER
WILL BE SHOWN ON PAGES 7
AND 8 AND INSTALLED ON
SITE.
EXISTING
COMBINER
PANEL
WILCKEN RESIDENCE
35 S HIDDEN VALLEY RD
REXBURG, IDAHO 83440