Loading...
HomeMy WebLinkAboutPLAN - 23-00802 - 35 S Hidden Valley Rd - Solar PanelsUtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 WILCKEN RESIDENCE 35 S HIDDEN VALLEY RD REXBURG, IDAHO 83440 Sheet 1 of 6 PLANT LOCATION Scale NTS PLANT LOCATION: WILCKEN RESIDENCE 35 S HIDDEN VALLEY RD REXBURG, IDAHO 83440 SOLAR EDGE SE7600H-US INVERTER 25 HANWHA Q.PEAK BLK-G4.1 295 PV PANELS SOLAR EDGE SE7600HUB-US INVERTER 31 SOLARIA POWERXT-400R-PM PANELS SOLAR EDGE SE5000H-US INVERTER 17 LG LG335N1C-A5 335 PV PANELS (2) SOLAR EDGE SE7600H-US INVERTER 47 HANWHA Q.PEAK DUO BLK-G5 310 PV PANELS SOLAR EDGE SE7600H-US INVERTER 25 JA JAM60S03-310/PR PV PANELS SOLAR EDGE SE3800H-US INVERTER 14 PANASONIC VBHN320KA03 320 PV PANELS SOLAR EDGE SE7600HUB-US INVERTER 25 S ENERGY SL40-60MBI-360V PANELS REVISION 1: ADDITION TO EXISTING SOLAR SYSTEM PLAN BY: BRYCE PETERSON SOLAR EDGE SE7600H-US INVERTER 25 VIKRAM SOMERA VSMHBB.60.365 TEXT UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 INSTALL SITE Scale NTSLIMITS OF CONSTRUCTION SOLADECK JUNCTION BOX (S) EXISTING COMBINER PANEL (LOCATED NEXT TO SERVICE) EXISTING 200A SERVICE ENTRANCE PANELBOARD Sheet 2 of 6 GENERAL NOTES: ALL CONSTRUCTION / INSTALLATION SHALL COMPLY WITH: 2017 NATIONAL ELECTRICAL CODE (NEC) 2018 INTERNATIONAL FIRE CODE (IFC) 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) ALL DIMENSIONS SHOWN ARE APPROXIMATE UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PV SYSTEM COMPONENTS LOCATED AT SERVICE ENTRANCE ALL CONDUITS ON ROOF SHALL BE A MINIMUM OF ½” OFF ROOF CONSTRUCTION LIMITS: ALL IMPROVEMENTS AND ACCESS SHALL OCCUR WITHIN PLANT PROPERTY LINES PHOTOVOLTAIC SYSTEM COMBINER PANEL 100A, 120/240 VAC LOAD CENTER DEDICATED PHOTOVOLTAIC SYSTEM AC DISCONNECT ESS BATTERY (LOCATED INSIDE GARAGE ON SIDEWALL) DEDICATED BATTERY SYSTEM AC DISCONNECT (LOCATED IN SIGHT OF BATTERY) EXISTING DEDICATED BATTERY SYSTEM UTILITY STOP DISCONNECT (LOCATED NEXT TO SERVICE) NEW 125A SUBPANEL (LOCATED IN SIGHT OF BATTERY) Portrait = 4 panels per 14’ rail Landscape = 2 panels per 14” rail Portrait = 1 rail to 2 panels (360W/400W = 2 rails to 3 panels) Landscape = 1 rail to 1 panel Splices = 2 for every consecutive 4 panels portrait (3 panels for 360W/400W)/ 2 panels landscape End Clamps = 2 on every end Mid Clamps = 2 on every joint between panel EXISTING 200A INTERIOR LOADS PANEL LOCATED IN BASEMENT DEDICATED PHOTOVOLTAIC SYSTEM AC DISCONNECT (LOCATED NEXT TO SERVICE) SOLADECK JUNCTION BOX (S) ONE PER ARRAY APPROX. 40' DC RUN (IN ATTIC WHERE AVAILABLE) SOLADECK JUNCTION BOX (S) ONE PER ARRAY B DEDICATED PHOTOVOLTAIC SYSTEM AC DISCONNECT (LOCATED NEXT TO SERVICE) PV METER SOCKET (LOCATED NEXT TO SERVICE) ESS BATTERY (LOCATED INSIDE GARAGE ON SIDEWALL IN THE FRONT 10 FEET OF GARAGE) TRENCH TRENCH EXISTING SOLAR ARRAYS (SHOWN IN BLUE) WILCKEN RESIDENCE 35 S HIDDEN VALLEY RD REXBURG, IDAHO 83440 (6)#14 AWG CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR UtahEnergySavers.com
 ESSolar.net
 Layton, UT 801-614-0606
 Scale
 NTS
Sheet 3 of 6
 4 #10 THWN-2 CU PV WIRE1 #10 THWN-2 CU GND3/4" EMT CONDUITSOLADECK JUNCTION BOX TRANSITION BOX AC ONE LINE DIAGRAM
 
 OTHER LOADS 40A/2P 60A/2P VISIBLY OPEN DISCONNECT (LOCATED WITHIN 3’ OF SERVICE) 30A/2P 40A/2P NEW 125A BACKUP LOADS SUBPANEL (LOCATED IN INTERIOR) NO SINGLE LOAD LARGER THAN 36A OR 8.64KVA (NEC 710.15) 125A SUBPANEL CT ETHERNET LINE TO HOME NETWORK A* D* E* F* A*-EXISTING MAIN SERVICE (SC816D200C) B*-30A/2P DISCONNECT (EATON DG221URB) C*-SONNEN CORE ESS (SONNENCORE20KWH) D*-NEW SUBPANEL (EATON BR816L125RP) E*-NEW SUBPANEL (EATON BR816L125RP) F*-60A/2P DISCONNECT (EATON DG222URB) G*-EXISTING ENPHASE COMBINER H*-HEAT/SMOKE DETECTOR (BRK SA520B) LOCATED IN CEILING ABOVE ESS (2)#10 AWG CU (1)#10 AWG NEUTRAL CU (1)#10 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR (2)#8 AWG CU (1)#8 AWG NEUTRAL CU (1)#8 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR AC CIRCUITS CONTINUE TO EXISTING MICROINVERTERS NEW INTERCONNECTED HEAT OR SMOKE DETECTOR H* (2)#8 AWG CU (1)#8 AWG NEUTRAL CU (1)#8 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR (2)#8 AWG CU (1)#8 AWG NEUTRAL CU (1)#8 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR EXTERIOR LOCATED LESS THAN 3 FT FROM MAIN 200A MAIN C* 20 KWH BATTERY SONNEN CORE ESS 4.8 KW INVERTER 40A AUTOMATIC TRANSFER SWITCH LOCKABLE DISCONNECT EXISTING LOCKABLE 30A/2P VISIBLY OPEN DISCONNECT B* C*-200A SUB PANEL (EATON BRP08B200RF) C*-200A SUB PANEL (EATON BRP12L200R) EXTERIOR SUBPANEL SIZES: BRP08B200RF = 8 BREAKER SLOTS BRP12L200R = 12 BREAKER SLOTS B*-NEW 125A SUBPANEL (EATON BR816L125RP) *WE WILL BE ADDING ONE 125A BREAKER TO THE MAIN SERVICE PANEL TO PROTECT THE EXISTING HOUSE FEEDER WIRES IN COMPLIANCE WITH NEC 705.12(B)(2)(1)(B)PV METERB*- PV METER BOX E*-30A/2P DISCONNECT (EATON DG221URB) 200A/2P 40A/2P OTHER LOADS (2)#6 AWG CU (1)#6 AWG NEUTRAL CU (1)#6 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR (2)#8 AWG CU (1)#8 AWG NEUTRAL CU (1)#8 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR (2)#10 AWG CU (1)#10 AWG NEUTRAL CU (1)#10 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR *WE WILL BE ADDING ONE 125A BREAKER TO THE MAIN SERVICE PANEL TO PROTECT THE EXISTING HOUSE FEEDER WIRES IN COMPLIANCE WITH NEC 705.12(B)(2)(1)(B) IN GARAGE (UNLESS OTHERWISE SPECIFIED) (2)#14 AWG CU (24V EMERGENCY STOP CONTACT) ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR (2)3/0 AWG CU / 4/0 AWG AL (1)3/0 AWG NEUTRAL CU / 4/0 AWG AL (1)#6 AWG EGC CU / #4 AWG AL 2” EMT MIN. W/ THWN-2 /SER CABLE (2)1/0 AWG CU / 2/0 AWG AL (1)1/0 AWG NEUTRAL CU / 2/0 AWG AL (1)#6 AWG EGC CU / # 4 AWG AL 1 ½ ” EMT MIN. W/ THWN-2 OUTDOOR / SER CABLE INDOOR (2)#1 AWG CU / 1/0 AWG AL (1)#1 AWG NEUTRAL CU / 1/0 AWG AL (1)#6 AWG EGC CU / #4 AWG AL 1 ½ ” EMT MIN. W/ THWN-2 OUTDOOR / SER CABLE INDOOR (2)#2 AWG CU / #2 AWG AL (1)#2 AWG NEUTRAL CU / #2 AWG AL (1)#8 AWG EGC CU / #6 AWG AL 1 ½ ” EMT MIN. W/ THWN-2 OUTDOOR / SER CABLE INDOOR OGDEN WIRE SIZES NEED TO BE CHANGED TO: (2)#8 AWG CU (1)#8 AWG NEUTRAL CU (1)#10 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR (2)#14 AWG CU (24V EMERGENCY STOP CONTACT) ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR OR SPEAKER WIRE OR SPRINKLER WIRE 2X 20A/2P B* 10A/2P EXISTING COMBINER WILCKEN RESIDENCE 35 S HIDDEN VALLEY RD REXBURG, IDAHO 83440 UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 SIGNAGE Scale NTS 1 DUAL INPUT SOURCE SECOND SOURCE IS SOLAR PV SYSTEM ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND NOT HAND-WRITTEN. NEC 110.21(B) SIGN LOCATED AT POINT OF INTERCONNECTION. NEC 690.56(B) AND 705.10 AND 712.10 2 WARNING:SOLAR POWER SOURCE OUTPUT CONNECTION, DO NOT RELOCATE THIS OVERCURRENT DEVICE SIGN LOCATED NEXT TO SOLAR BACKFEED BREAKERS AT SERVICE PANEL. IF BREAKER FEED AND UTILIZING THE 120% RULE NEC 705.12(B)(2)(3)(b) 3 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM SIGN LOCATED NEXT TO THE SOLAR AC OR DC DISCONNECT THAT ACTIVATES RAPID SHUTDOWN. NEC 690.56 (C) (3) OR NEXT TO MAIN SERVICE DISCONNECT OR NEXT TO A RSD RELAY SIGNAL BUTTON THE MARKINGS SHALL BE REFLECTIVE WHITE ON RED BACKGROUND 5 PHOTOVOLTAIC POWER SOURCE THIS SIGN IS LOCATED ON THE OUTSIDE OF ANY CONDUITS, ENCLOSURES, OR MC CABLE THAT CONTAINS DC CIRCUITS. The markings shall be reflective and be provided at every enclosure, every 10’ along conduit or MC cable, and at each side of where the conduit or cable passes through a wall, floor, or any other partition. NEC 690.31(G)(3-4) and IFC 605.11.1.2 8 4 PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH MAX SYSTEM VOLTAGE= 480 VDC MAX CIRCUIT CURRENT= 15 ADC MAX CURRENT FOR POWER OPTIMISERS= 15 ADC THIS SIGN IS LOCATED ON THE OUTSIDE OF EACH DC DISCONNECT. NEC 690.53 and 690.13(B) 7 PV SYSTEM BACKFEEDING THROUGH THIS PANEL AC OUTPUT CURRENT= 32 AAC AC VOLTAGE=240 VAC THIS SIGN IS LOCATED AT THE BACKFEED PANEL BOARD NEC 690.54 Sheet 4 of 6 11PHOTOVOLTAIC SYSTEM DEDICATED KWH METER THIS SIGN IS LOCATED AT THE DEDICATED KWH METER 6 NOTICE: PV SYSTEM COMBINER PANEL DO NOT ADD LOADS TO THIS PANEL THIS SIGN IS LOCATED AT THE COMBINER PANEL PHOTOVOLTAIC SYSTEM AC DISCONNECT THIS SIGN IS LOCATED AT THE AC PV SYSTEM DISCONNECT 690.13 (B) THIS SIGN IS LOCATED ON OR WITHIN 3’ FEET OF THE SERVICE METER PANELBOARD AND ON ANY AC DISCONNECT SWITCH ON THE OUTSIDE OF THE BUILDINGS NEC 690.56(C)(1) / IFC 1204.5.1 9 SE3000H-US 12.5 SE3800H-US 16 SE5000H-US 21 SE6000H-US 25 SE7600H-US 32 SE10000H-US 42 SE11400A-US 47.5 Ansi z535.4 color specific ENERGY STORAGE SYSTEM DISCONNECT NOMINAL ESS AC VOLTAGE=_240_VAC MAXIMUM ESS DC VOLTAGE=_204_VDC SIGN LOCATED AT ENERGY STORAGE SYSTEM DISCONNECTS NEC 706.15(C) 10 9 CAUTION: MULTIPLE SOURCES OF POWER POWER TO THIS SERVICE IS ALSO SUPPLIED FROM A PV SYSTEM CONNECTED TO THE AC SERVICE PANEL. LITHIUM BATTERY IS LOCATED IN GARAGE (SIDEWALL) MICROINVERTERS ARE LOCATED AT EACH MODULE BATTERY LIGHTS WILL BE OFF WHEN EMERGENCY STOP ACTIVE THIS DIRECTORY LOCATED AT POINTS OF INTERCONNECTION. NEC 690.56(B) AND 705.10 AND 706.21 AND 710.10 AND 712.10 ALSO PER UTILITY REQUIREMENTS WILCKEN RESIDENCE 35 S HIDDEN VALLEY RD REXBURG, IDAHO 83440 UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 PLACARDS Scale NTS ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND NOT HAND-WRITTEN. NEC 110.21(B) Sheet 5 of 6 11 PARALLEL GENERATION ON SITE THIS PLACARD IS LOCATED NEXT TO METER SOCKET. 2”X4” ENGRAVED METAL OR RED AND WHITE HARD PLASTIC ⅜” OR LARGER LETTERS MANUAL DISCONNECT FOR BATTERY THIS PLACARD IS LOCATED AT THE AC ESS SYSTEM DISCONNECT. 2”X4” ENGRAVED METAL OR RED AND WHITE HARD PLASTIC ⅜” OR LARGER LETTERS 12 N MANUAL DISCONNECT FOR PARALLEL GENERATION THIS PLACARD IS LOCATED AT THE AC PV SYSTEM DISCONNECT. 2”X4” ENGRAVED METAL OR RED AND WHITE HARD PLASTIC ⅜” OR LARGER LETTERS 13 MANUAL DISCONNECT FOR PARALLEL GENERATION AND BATTERY THIS PLACARD IS LOCATED AT THE AC ESS SYSTEM DISCONNECT. 2”X4” ENGRAVED METAL OR RED AND WHITE HARD PLASTIC ⅜” OR LARGER LETTERS 12 WARNING: MULTIPLE SOURCES OF POWER. A PV SYSTEM IS PRESENT. DISCONNECT ALL POWER SOURCES BEFORE SERVICING. FOR ST GEORGE POWER WILCKEN RESIDENCE 35 S HIDDEN VALLEY RD REXBURG, IDAHO 83440 UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 Scale NTS SIGNAGE LOCATION Sheet 6 of 6 *5 *5 *5 *5 *5 *5 *5 *1,*9 EXISTING 200A MAIN SERVICE PANEL TRANSITION BOX SOLADECK JUNCTION BOXES IN ATTIC (EXTERIOR *7) (NEXT TO BREAKER *2,*6)*11, *1,*8,*13 * NOT REFLECTIVE OF ACTUAL EQUIPMENT LOCATION NEW SUBPANEL AC DISCONNECT SONNEN ESS IN GARAGE *1, *2, *6, *10
 *3,*8, *13 EXISTING LOCKABLE VISIBLY OPEN DISCONNECT *3, *10, *12 * FOR SIGNAGE AND PLACARDS SEE PAGES 7 AND 8 *ONLY APPLICABLE STICKER WILL BE SHOWN ON PAGES 7 AND 8 AND INSTALLED ON SITE. EXISTING COMBINER PANEL WILCKEN RESIDENCE 35 S HIDDEN VALLEY RD REXBURG, IDAHO 83440