SYSTEM RECORD OF COMPLETION - 22-00283 - Teton River Lofts - 24 Units - Bldg 2
SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 1 of 3) Form Completion Date: Supplemental Pages Attached: 1. PROPERTY INFORMATION Name of property: Address: Description of property: Name of property representative: Address: Phone: Fax: E-mail: 2. INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: Address: Phone: Fax: E-mail: Service organization: Address: Phone: Fax: E-mail: Testing organization: Address: Phone: Fax: E-mail: Effective date for test and inspection contract: Monitoring organization: Address: Phone: Fax: E-mail: Account number: Phone line 1: Phone line 2: Means of transmission: Entity to which alarms are retransmitted: Phone: 3. DOCUMENTATION On-site location of the required record documents and site-specific software: 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: New system Modification to existing system Permit number: NFPA 72 edition: 4.1 Control Unit Manufacturer: Model number: 4.2 Software and Firmware Firmware revision number: 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds 10/23/2023 Teton River Lofts BLDG 2 311 E Lorene St, Rexburg, Idaho 83440 3 story apartment complex Nephi’s Electric 208-313-2883 State Fire Idaho 610 Malard St. Chubbuck, Idaho 83202 208-232-3640 State Fire Idaho 10/23/2023 State Fire Idaho/ Avantgard 877-206-9141 897733 None None Starlink Cell Dialer Rexburg Dispatch Inside panel 2016 Notifier NFW-50X Bryson Siddoway. Venture Builders 208-715-1044 22-00283 SYSTEM RECORD OF COMPLETION (continued) Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 2 of 3) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: Control panel amps: Overcurrent protection: Type: Amps: Branch circuit disconnecting means location: Number: 5.1.2 Secondary Power Type of secondary power: Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): In alarm mode (minutes): 5.2 Control Unit This system does not have power extender panels Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line Device Power Initiating Device Notification Appliance Other (specify): 7. REMOTE ANNUNCIATORS Type Location 8. INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations Smoke Detectors Duct Smoke Detectors Heat Detectors Gas Detectors Waterflow Switches Tamper Switches 120vac 10 Breaker 15 HOA panel Rear IT 9 Battery (2) 12v12amp batteries B B B Y None 1 1 1 2 Addressable Addressable Conventional with module Conventional with module Alarm Alarm Alarm Supervisory Switch Photo Switch Switch Notifier PSE-10 (2) 12v18amp batteries, 6 horn circuits, triggered by FACP NAC 1. 0 0 0 SYSTEM RECORD OF COMPLETION (continued) Copyright © 2012 National Fire Protection Association. This form may be copied for individual use other than for resale. It may not be copied for commercial sale or distribution. (p. 3 of 3) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible Visible Combination Audible and Visible 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS This system does not have interconnected systems. Interconnected systems are listed on supplementary sheet . 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified herein has been installed according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 12.3 Acceptance Test Date and time of acceptance test: Installing contractor representative: Testing contractor representative: Property representative: AHJ representative: 4 64 Wall white horns Wall white horn/strobe and FDC Horn/Strobe Teancum Gibson 208-201-5964Nephi’s Electric Michael Beal 10/23/2023 State Fire Idaho Install Technician 208-251-9431 10/23/2023 0 N/A | | | | | | | Alex Owens