Loading...
HomeMy WebLinkAboutPLANS - 23-00766 - Crapo 3 Plex - Remodel1 2 3 4 5 AL E X V A L E N C I A D E S I G N ph o n e : 9 3 7 . 2 3 2 . 0 0 3 7 av b a l l 8 @ g a m i l . c o m RE V . DA T E BY DE S C R I P T I O N PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : CURRENT REV. A000 Pr o j e c t N u m b e r CO V E R S H E E T Au t h o r B U I L D I N G 1 5 6 15 6 E 2 N D S , R E X B U R G , I D 8 3 4 4 0 CR A P O BUILDING 156 • SCALE: 1/4" = 1'-0" • SQFT: 3,091 • REMODEL & REPAIR • REPLACE DAMAGED AND EXISTING ADD-ON, REMODEL INTERIOR INTO THREE APARTMENTS SHEET INDEX SHEET DESCRIPTION DETAILS A000 COVER SHEET A100 SITE PLAN A101 FLOOR PLANS A102 ELEVATIONS E 2ND S 41 ' - 0 " 41' - 0" 13 0 ' - 0 " 44 ' - 1 1 5 / 8 " 72 ' - 0 3 / 8 " 13 ' - 0 " 7' - 2"27' - 10"6' - 0" 1 2 3 4 5 AL E X V A L E N C I A D E S I G N ph o n e : 9 3 7 . 2 3 2 . 0 0 3 7 av b a l l 8 @ g a m i l . c o m RE V . DA T E B Y D E S C R I P T I O N PR O J E C T M A N A G E R : C A D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : CURRENT REV. A100 Pr o j e c t N u m b e r SI T E P L A N Au t h o r B U I L D I N G 1 5 6 15 6 E 2 N D S , R E X B U R G , I D 8 3 4 4 0 CR A P O 1/8" = 1'-0"1 Site NORTH 27' - 4 1/4" 38 ' - 8 1 / 4 " 9' - 3 1 / 8 " 24 ' - 1 " 11' - 1"5' - 7"11' - 2" 27' - 10" 72 ' - 0 3 / 8 " 15 ' - 0 " 5' - 7 3 / 8 " 12 ' - 0 " 15 ' - 1 0 " 15' - 3 1/4" 15 ' - 6 " 15 ' - 9 " 5' - 0 " 9' - 3" 13' - 7" 10 ' - 7 3 / 8 " BEDROOM FAMILY KITCHEN BATH BEDROOM BEDROOM BEDROOM FAMILY KITCHEN BATH LAUNDRY STAIR 8' - 10" 2' - 7 " 5' - 3 " 12 ' - 4 " 11' - 4 5/8" 3' - 6" 5' - 0" 21' - 3 3/4" LAUNDRY 3' - 6 " 2' - 0 " 7' - 9 " 2' - 0 " 5' - 1 0 " 2' - 0 " 0' - 8 " 3' - 2 " 4' - 6 " 4' - 0 " 9' - 9 1 / 4 " 2' - 0 " 3' - 0 " 5' - 8 " 2' - 0 " 10 ' - 6 " 5' - 6 " 7' - 9 " 5' - 0 " 4' - 2 " 5' - 4 " 1' - 1 " 0' - 2 " 4' - 4 1/2" 8' - 0 3 / 8 " 12 ' - 0 " 9' - 10 5/8" 2' - 0 " CLOSET 9' - 7"7' - 1"9' - 8" 2' - 6 1 / 2 " 4' - 0 " 1' - 1 1 " 15 ' - 1 0 " 12 ' - 7 " 1' - 10 1/2"4' - 6"1' - 10 1/2" 2' - 6 " 1' - 0"2' - 6"1' - 8 1/2"3' - 0"4' - 0"4' - 8"2' - 6"2' - 11 3/4"4' - 0"1' - 0" 11 22 33 44 55 8' - 1 1 " 38 ' - 8 1 / 2 " 8' - 2 7 / 8 " 15 ' - 1 0 " A A B B C C D D 10' - 5"3' - 7"13' - 4 1/4" SD SD SD SD SDSD SD SD 9' - 2" 6' - 9 " 16' - 6 3/4" 13 ' - 2 " 25 ' - 6 1 / 2 " 12' - 8 7/8"12' - 9 3/8"10 ' - 1 1 / 2 " 2' - 1 1 " 8' - 7" 6' - 8 7 / 8 " 11' - 4 3/4" 5' - 4 1 / 2 " 10' - 2 3/4" 8' - 1 " 10' - 1 1/4"15' - 11 1/2" 8' - 1 " 11 ' - 0 3 / 8 " 15' - 5 1/2" 26' - 11 3/4" 27 ' - 5 1 / 2 " 20 ' - 2 3 / 8 " 47 ' - 7 7 / 8 " 33 ' - 6 3 / 8 " 14 ' - 3 1 / 2 " 2' - 8 3/4"3' - 9"20' - 10" 27' - 3 3/4" 4' - 2 3/8"4' - 8 5/8" 8' - 0 1/4" BATH FAMILY KITCHEN BEDROOM BEDROOM PANTRY STORAGE MECH STAIR 6' - 0 " 5' - 8" LAUNDRY 4' - 6 " 5' - 1 " 3' - 0 " 8' - 2 " 2' - 5 " 11 22 33 44 5 A A B B C C D D SD SD SD SD 1 2 3 4 5 AL E X V A L E N C I A D E S I G N ph o n e : 9 3 7 . 2 3 2 . 0 0 3 7 av b a l l 8 @ g a m i l . c o m RE V . DA T E B Y D E S C R I P T I O N PR O J E C T M A N A G E R : C A D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : CURRENT REV. A101 Pr o j e c t N u m b e r FL O O R P L A N S AV B U I L D I N G 1 5 6 15 6 E 2 N D S , R E X B U R G , I D 8 3 4 4 0 CR A P O 1/4" = 1'-0"2 MAIN LEVEL 1/4" = 1'-0"1 BASEMENT NORTH KEYNOTES 1 AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED PER ICC SECTION 903.3 2 NEW EXTERIOR WALLS TO BE CLAD IN VINYL SIDING 3 EXISTING EXTERIOR WALLS CLAD IN BRICK BASEMENT 0' -0" MAIN LEVEL 9' -0" ROOF 18' -0" 2 BASEMENT 0' -0" MAIN LEVEL 9' -0" ROOF 18' -0" 3 BASEMENT 0' -0" MAIN LEVEL 9' -0" ROOF 18' -0" 3 2 BASEMENT 0' -0" MAIN LEVEL 9' -0" ROOF 18' -0" 2 3 1 2 3 4 5 AL E X V A L E N C I A D E S I G N ph o n e : 9 3 7 . 2 3 2 . 0 0 3 7 av b a l l 8 @ g a m i l . c o m RE V . DA T E B Y D E S C R I P T I O N PR O J E C T M A N A G E R : C A D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : CURRENT REV. A102 Pr o j e c t N u m b e r EL E V A T I O N S AV B U I L D I N G 1 5 6 15 6 E 2 N D S , R E X B U R G , I D 8 3 4 4 0 CR A P O 1/4" = 1'-0"1 South 1/4" = 1'-0"2 North 1/4" = 1'-0"3 West 1/4" = 1'-0"4 East KEYNOTES 1 AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED PER ICC SECTION 903.3 2 NEW EXTERIOR WALLS TO BE CLAD IN VINYL SIDING 3 EXISTING EXTERIOR WALLS CLAD IN BRICK CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV. GSN DN. DWG(S) EQ. EQUIP. EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA. F.O.M. EXP. BOLT E.O.S. o OR DIA. C.I.P. C.L. C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT. D.L. C.L.F. W/ WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP. VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T.L. SLH SLV SIM. SQ. PSF PSI REINF. PREFAB OPP. P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT. A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH'L. N/A LLV LLH HORIZ. K(KIP) GLB (GLULAM) I.F.W. L.L. LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL GLUED-LAMINATED BEAM INSIDE FACE OF WALL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN. MINIMUM MAX. MAXIMUM SYMBOLS LEGEND WALLS WITH SOLID LINES DESIGNATE STRUCTURAL (BEARING) WALLS. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. WALLS WITH HATCH DESIGNATE MASONRY WALLS. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. 5 6 7 , , - AS SHOWN ON PLAN INDICATES A SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION. A B INDICATES HVAC EQUIPMENT ON ROOF OR IN ATTIC SPACE. SEE TYPICAL DETAILS FOR FRAMING INFORMATION. - AS SHOWN ON PLAN INDICATES A HELICAL PIER. XXXX CS16, CMSTC16, ECT. - AS SHOWN AT WALL OPENINGS INDICATE STRAPPING, PROVIDE STRAPPING PER "TYPICAL STRAP AT OPENING" DETAIL. D=xxx# INDICATES DRAG LOAD (ASD) THAT TRUSS MANUFACTURER IS TO DESIGN TRUSS FOR IN BOTH TENSION AND COMPRESSION. STEP INDICATES STEPPED OR DEPRESSED SLAB. C=X" INDICATES CAMBER IN BEAM. INDICATES RIDGID CONNECTION. (NOT ALL SYMBOLS NECESSARILY APPLY TO THIS PROJECT) P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. SC1, SC2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL COLUMN. SEE STEEL COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. COLUMNS START AT THE LEVEL THEY ARE CALLED OUT ON. PX SCX RME XXX# 1 2 3 4 5 fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d St r u c t u r a l E n g i n e e r i n g Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 in f o @ f r o s t - s t r u c t u r a l . c o m RE V . DA T E BY DE S C R I P T I O N Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n gi n e e r i n g , I n c . Le g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r in p i e c e s . I t is o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i ca l l y i d e n t i f i e d he r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r sh a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d c o n d i t i o n s a n d re p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r o m i s s i o n d i s c o v e r e d be f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : CURRENT REV. FR O S T S1.0 GE N E R A L S T R U C T U R A L N O T E S AV C R A P O 1 5 6 15 6 E 2 n d S RE X B U R G , I D 83 4 4 0 CR A P O SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.2 TYPICAL DETAILS T - SERIES S2.0 FOUNDATION PLAN --- S2.1 FIRST FLOOR FRAMING PLAN --- S2.2 ROOF FRAMING PLAN --- S3.0 FOUNDATION DETAILS 100 - SERIES S4.0 FLOOR FRAMING DETAILS 200 - SERIES S5.0 ROOF FRAMING DETAILS 300 - SERIES LOCATION LIVE / SNOW LOAD DEAD LOAD ELEMENTS LIVE LOAD TOTAL LOAD LOCATION:MINIMUM COVER TOLERANCE USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT USE:MATERIAL: GENERAL REQUIREMENTS: BASIS FOR DESIGN: FOUNDATION NOTES:CONCRETE:WOOD:DEFERRED SUBMITTAL ITEMS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. 1.BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 4. SEISMIC DESIGN PARAMETERS: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SITE CLASS D (ASSUMED) SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.154, SS = 0.446 DESIGN SPECTRAL RESPONSE ACCELERATIONS PERCENT SNOW INCLUDED WITH SEISMIC LOADS 20 VERTICAL SHEAR TRANSFER ELEMENTS: PLYWOOD SHEARWALL(S)R = 6.5, CS = 0.066 5. WIND DESIGN PARAMETERS (STRENGTH): ULTIMATE WIND SPEED 115 MPH (3 SECOND GUST) WIND EXPOSURE C IMPORTANCE FACTOR Iw = 1.00 INTERNAL PRESSURE COEFFICIENT -0.18 COMPONENT AND CLADDING PRESSURE 29.3 PSF NET UPLIFT ON ROOF 18.5 PSF 2. VERTICAL LOADS: ROOF ROOF = 30 PSF GROUND = 40 PSF 15 PSF FLOOR 40 PSF 20 PSF STAIRS 100 PSF 25 PSF 3. DEFLECTION LIMITS: ROOF TRUSSES/JOISTS L/360 L/240 FLOOR TRUSSES/JOISTS L/720 L/240 BEAMS L/360 L/240 1.IN LIEU OF A GEOTECHNICAL REPORT: THE FOUNDATION HAS BEEN DESIGNED ACCORDING TO THE RECOMMENDATIONS OF CHAPTER 18 OF THE IBC. 2.THE SOIL DESIGN VALUES LISTED BELOW HAVE BEEN APPROVED BY THE CITY/COUNTY BUILDING DEPARTMENT, CONTINGENT THAT THE SOIL ON THE SITE PREDOMINATELY CONSISTS OF SAND AND/OR GRAVEL. SPECIFIC SOIL CLASSIFICATIONS SHOULD BE ONE OF THE FOLLOWING: SANDY GRAVEL OR GRAVEL(GW OR GP), SAND(SW AND SP), SILTY SAND(SM), CLAYEY SAND(SC), SILTY GRAVEL(GM), OR CLAYEY GRAVEL(GC). THESE SOIL CLASSIFICATIONS CAN BE FOUND IN TABLE 1806.2 OF CHAPTER 18 OF THE IBC. VERIFICATION OF SOIL CLASSIFICATION IS THE RESPONSIBILITY OF THE CONTRACTOR. 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL OR COMPETENT NATIVE SOIL SUBBASE COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR). GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 1500 PSF ALLOWABLE LATERAL BEARING PRESSURE 150 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 LATERAL BACKFILL PRESSURE (UNRESTRAINED) 45 PSF/FT LATERAL BACKFILL PRESSURE (RESTRAINED) 60 PSF/FT FOUNDATION BEARING DEPTH 30" BELOW FINISHED GRADE 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. . 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6. NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10.FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11. COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. CAST AGAINST EARTH (FOOTINGS)3"± 3/8" SLABS ON GRADE 1 1/2" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1" STRUCTURAL SLABS AND WALLS BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: FOOTINGS 3500 PSI 0.50 5.5% ± 1% FOUNDATION WALLS 4500 PSI 0.45 5.5% ± 1% INTERIOR CONCRETE SLABS ON GRADE 3500 PSI 0.45 N/A BEAMS, COLUMNS, ELEVATED SLABS, WALLS 4500 PSI 0.45 5.5% ± 1% 1.GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. DOUBLE UP JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" (NOMINAL) SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. UNLESS NOTED OTHERWISE ON PLANS/DETAILS PROVIDE 2x SOLID BLOCKING AT MID-HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO IBC TABLE 2304.10.1. JOIST HANGERS AND OTHER MISC. FRAMING ANCHORS SHALL BE SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT ICC-ES APPROVAL. 2.SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB). ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. SAWN LUMBER SHALL HAVE THE FOLLOWING MINIMUM GRADE UNLESS NOTED OTHERWISE IN SCHEDULES: 2x4 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) 2x6 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) JOISTS, TOP PLATES AND ALL OTHER SAWN LUMBER DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) BEAMS AND POSTS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) LOCATION:NOMINAL THICKNESS: SPAN INDEX RATING: EDGE ATTACHMENT: FIELD ATTACHMENT: WALL 8d AT 6" O.C. 8d AT 12" O.C. ROOF 8d AT 6" O.C. 8d AT 12" O.C. ROOF 8d AT 6" O.C. 8d AT 12" O.C. ROOF 10d AT 6" O.C.10d AT 12" O.C. ROOF 10d AT 6" O.C. 10d AT 12" O.C. ROOF 10d AT 6" O.C. 10d AT 12" O.C. FLOOR 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. 3.PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: SCREWS AT FLOOR SHEATHING SHALL BE #8 SCREWS AND SHALL PENETRATE AT LEAST 1 1/2" INTO THE SUPPORTING MEMBER. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH AN APA AFG-01 QUALIFIED ADHESIVE. PLYWOOD ALTERNATE: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ARCHITECT AND ROOFER. IT MAY NOT BEUSED ON ROOFS WHERE BUILT UP ROOF SYSTEM IS TO BE GUARANTEED BY ROOFER. RATED SHEATHING SHALL COMPLY WITH CURRENT ICC-ES REPORTS AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 1/32") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4.NOMINAL 2x AND 3x DECKING. TONGUE AND GROOVE TYPE. MINIMUM Fb = 1,600 PSI, MINIMUM E = 1,300,000 PSI. INSTALL WITH TONGUES UP SLOPE ON PITCHED ROOFS, AND OUTWARD IN THE DIRECTION OF LAYING ON FLAT ROOFS. NAIL EACH PLANK WITH 16d TOENAIL (THRU THE TONGUE) AND 16d FACE NAIL AT EACH SUPPORT. DECK SHALL BE INSTALLED AS SIMPLE SPAN WITH ALL PLANKS BEARING ON TWO SUPPORTS. FOR REFERENCE AND/OR ADDITIONAL INFORMATION SEE AITC 117-2010. 5.GLUED-LAMINATED BEAMS (GLB): GLUED-LAMINATED BEAMS SHALL BE DOUGLAS FIR COMBINATION AT 24F-V4 AT SIMPLE SPAN BEAMS AND 24F-V8 AT MULTI-SPAN AND CANTILEVERED BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: FB = 2,400 PSI, FV = 190 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,800 KSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. STANDARD CAMBER IS BASED ON A RADIUS OF CURVATURE OF 2000 FEET. 6.GLUED-LAMINATED COLUMNS: GLUED-LAMINATED COLUMNS SHALL BE DOUGLAS FIR COMBINATION 3 WITH THE FOLLOWING MINIMUM PROPERTIES: FBY = 2,100 PSI, FBX = 2000 PSI, FVY = 230 PSI, FVX = 265 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,900 KSI. ALL COLUMNS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. COLUMNS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. 7. LAMINATED VENEER LUMBER (LVL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LVLs SHALL BE: FB = 2,600 PSI, FV = 285 PSI, E = 2,000 KSI. 8.PARALLEL STRAND LUMBER (PSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR PSLs SHALL BE: FB = 2,900 PSI, FV = 290 PSI, E = 2,000 KSI. 9.LAMINATED STRAND LUMBER (LSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LSLs SHALL BE: FB = 2,325 PSI, FV = 310 PSI, E = 1,550 KSI. 10.SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF TREATED FIR. SHEAR WALLS AND EXTERIOR WALL SILLS AT CONCRETE SLAB SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS PER PIECE. PROVIDE ANCHOR BOLT AT 9" MAXIMUM, 4" MINIMUM FROM THE END OF EACH PIECE AT SPLICE OR END OF WALL. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72" ON CENTER UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FOR HOLDOWNS) SHALL EMBED 7" INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE SECURED TO CONCRETE WITH EITHER ANCHOR BOLTS OR POWER DRIVEN SHOT PINS UNLESS NOTED OTHERWISE ON PLANS. 11. BOLTING: ALL BOLTS IN WOOD CONNECTIONS SHALL CONFORM TO ASTM A307. BOLTS SHALL BE INSTALLED IN HOLES BORED WITH A BIT 1/16" LARGER THAN THE Ø (DIAMETER) OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NICK THREADS TO PREVENT LOOSENING. 12. PREFABRICATED WOOD ROOF TRUSSES BALCONY 60 PSF 20 PSF SD1 = 0.235, SDS = 0.429 GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) ± 1/4" 1 1/2" ± 3/8" ± 3/8" 1/8" 3/4"1/8" 1 1/2" 3/8" PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. WHERE UNINHABITABLE ATTIC SPACE CAN BE USED FOR STORAGE, A 20 PSF LIVE LOAD ON THE BOTTOM CHORD SHALL BE INCLUDED IN THE ANALYSIS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE FOR BOTH ROOF AND FLOOR TRUSSES WHEN USED. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC-ES APPROVAL. ADDITIONAL TRUSSES SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PER IBC SECTION 2303.4 AND TPI-1: EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS, THE DESIGN LOADS, AND THE TRUSS SPACING - WITHIN TWO FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD. PREFABRICATED WOOD/STEEL WEB JOIST/PURLINS (TJI/TJL SERIES OR EQUAL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST EDITION ICC-ES REPORT. CONNECTIONS AND BEARING MATERIAL TO BE DESIGNED AND FURNISHED BY JOIST FABRICATOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED STRUCTURAL ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. ADDITIONAL JOISTS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. 7/16" OR 1/2" 7/16" OR 1/2" 15/32" OR 1/2" 19/32" OR 5/8" 23/32" OR 3/4" 7/8" 3/4" T&G 7/8" T&G 1 1/8" T&G 24/16 24/16 32/16 40/20 48/24 60/32 48/24 60/32 60/48 GYPBOARD SHEARWALL(S)R = 2.0, CS = 0.227 SPECIAL MASONRY SHEARWALL(S)R = 5.0, CS = 0..134 ORDINARY STEEL MOMENT FRAME(S)R = 3.5, CS = 0.0.134 1. (USE THE NEXT 4 PARAGRAPHS IF THERE IS NO SOIL REPORT) 2.SITE PREPARATION AND GRADING REQUIREMENTS OF THE SOIL REPORT AND ANY ADDENDUM'S SHALL BE COMPLETED PRIOR TO CONSTRUCTION OF FOUNDATIONS. ANY TESTS OR INSPECTIONS REQUIRED BY THE SOIL REPORT SHALL BE PERFORMED PRIOR TO PLACEMENT OF FOUNDATION REINFORCING STEEL OR CONCRETE. ALTERATIONS TO SITE PREPARATION OR GRADING SHALL BE REPORTED TO THE GEOTECHNICAL ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. FOUNDATIONS DESIGNED IN CONFORMANCE WITH RECOMMENDATIONS BY: ENGINEERING TESTING CONSULTANTS, INC. REPORT NO. 3456 DATED JANUARY 1, 2007. REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, AND ELEVATED SLAB REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. STEEL: 1. MATERIALS: ROLLED W SHAPES, SHALL CONFORM TO ASTM A992 (FY=50 KSI). ALL OTHER STRUCTURAL STEEL SHAPES, ROLLED SECTIONS, BARS AND PLATES SHALL CONFORM TO ASTM A36 (FY = 36 KSI). ALL PIPE STEEL SHALL BE ASTM A501 (FY = 36 KSI) OR ASTM A53, TYPE E OR S, GRADE B (FY = 35 KSI). ALL TUBULAR STEEL SHALL BE ASTM A500 (FY = 46 KSI). 2.ALL BOLTS AND STUDS SHALL BE ASTM A307, UNLESS NOTED OTHERWISE. ALL EXPANSION BOLTS TO HAVE CURRENT ICC REPORT RATING FOR MATERIAL INTO WHICH INSTALLATION TAKES PLACE. HEADED STUDS SHALL CONFORM TO ALL REQUIREMENTS OF THE LATEST EDITION OF THE "RECOMMENDED PRACTICES FOR STUD WELDING" AND THE "STRUCTURAL WELDING CODE" PUBLISHED BY AWS. ALL BOLTS, ANCHOR BOLTS, EXPANSION BOLTS, ETC. SHALL BE INSTALLED WITH STEEL WASHERS AT FACE OF WOOD OR AT SLOTTED HOLES IN STEEL SECTIONS. 3. ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, LATEST EDITION. 4.WELDING SHALL BE BY WELDERS HOLDING VALID CERTIFICATES AND HAVING CURRENT EXPERIENCE IN THE TYPE OF WELD SHOWN ON THE DRAWINGS OR NOTES. ALL WELDING SHALL USE E70 SERIES LOW HYDROGEN RODS UNLESS NOTED OTHERWISE. ALL WELDING PER LATEST AMERICAN WELDING SOCIETY STANDARDS. ALL WELDS ON DRAWINGS ARE SHOWN AS SHOP WELDS. CONTRACTOR MAY SHOP WELD OR FIELD WELD AT HIS DISCRETION. ALL FULL PENETRATION WELDS SHALL BE TESTED AND CERTIFIED BY AN INDEPENDENT TESTING LABORATORY. 5.STEEL TO STEEL BOLTED CONNECTIONS: HIGH STRENGTH BOLTS SHALL BE ASTM A325N AND SHALL BE INSTALLED AS BEARING-TYPE CONNECTIONS WITH THREADS INCLUDED IN SHEAR PLANE (TYPE "N" CONNECTION UNLESS NOTED OTHERWISE). BOLTS MAY BE TIGHTENED USING ANY AISC APPROVED METHOD. 6.DRYPACK SHALL BE 5,000 PSI FIVE STAR NON-SHRINK GROUT OR EQUIVALENT. INSTALL DRYPACK UNDER BEARING PLATES BEFORE FRAMING MEMBER IS INSTALLED. AT COLUMNS, INSTALL DRYPACK UNDER BASE PLATES AFTER COLUMN HAS BEEN PLUMBED BUT PRIOR TO FLOOR OR ROOF INSTALLATION. 7.SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN ADDITION TO ITEMS REQUIRED BY ARCHITECTURAL SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DRAWINGS SHALL BE FLAGGED UPON HIS REVIEW. VERIFY ALL DIMENSIONS WITH ARCHITECT. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER THE STRUCTURAL ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A STRUCTURAL ENGINEER REGISTERED IN THE APPROPRIATE STATE. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER ARE NOT TO BE CONSIDERED CHANGES TO ORIGINAL DRAWINGS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY THE OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ALLOW (5) WORKING DAYS FOR THE STRUCTURAL ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL WILL BE RETAINED FOR THE STRUCTURAL ENGINEER'S RECORDS. (ONLY USE THE FOLLOWING PARAGRAPH ON COMMERCIAL PROJECTS) 3.PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. EXTERIOR WALL PLYWOOD SHEATHING SHALL BE PRESSURE-TREATED WITH FIRE- RETARDENT-TREATED (FRT) (OR EQUIVALENT) TO MEET UNDERWRITERS LABORATORIES FR-S RATING OR A FLAME SPREAD AND SMOKE INDEX RATING DENOTING A SURFACE BURNING CHARACTERISTIC RATING OF 25 OR LESS FOR FLAME SPREAD AND SMOKE DEVELOPED. SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OR STAMP ATTESTING TO THE FR-S RATING OR FRAME SPREAD AND SMOKE INDEX RATING, OR HAVE A CURRENT ESR BUILDING CODE APPROVAL. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: CONCRETE SLAB ON GRADE CONCRETE SLAB ON GRADE W/ EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) 4"4 AT 24" O.C. WF 1 8 A WF 1 8 A WF 1 8 A WF 1 8 A WF 1 8 A WF 1 8 A WF 1 8 WF 1 8 WF18 F30 F30 F30 EWF18 EWF18 EWF18 EW F 1 8 EW F 1 8 EW F 1 8 EW F 1 8 27'-1 3/4" 8' - 3 " 27 ' - 8 1 / 2 " 20 ' - 5 1 / 2 " 15 ' - 3 1 / 2 " 71 ' - 8 1 / 2 " 7' - 7 1 / 2 " 1' - 1 " 5' - 4 " 13 ' - 1 0 " 10 ' - 1 1 1 / 2 " 3' - 4 " 5' - 5 1 / 2 " 5' - 9 1 / 2 " 8' - 1 1 " 27'-4 1/4" 1'-9 1/2" 1 2 3 4 5 A B C D W1 EW1 EW1 EW1 W1 W1 EW 1 EW F 1 8 E W 1 EW 1 EW 1 EW 1 5 6.6. 5 5 1 2 3 4 5 fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d St r u c t u r a l E n g i n e e r i n g Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 in f o @ f r o s t - s t r u c t u r a l . c o m RE V . DA T E B Y D E S C R I P T I O N Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n gi n e e r i n g , I n c . Le g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r in p i e c e s . I t is o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i ca l l y i d e n t i f i e d he r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r sh a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d c o n d i t i o n s a n d re p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r o m i s s i o n d i s c o v e r e d be f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . PR O J E C T M A N A G E R : C A D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : CURRENT REV. FR O S T S2.0 FO U N D A T I O N P L A N Au t h o r C R A P O 1 5 6 15 6 E 2 n d S RE X B U R G , I D 83 4 4 0 CR A P O NORTH WALL (W) SCHEDULE TYPE MATERIAL THICKNESS VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS EW1 CONCRETE 8" #4 AT 18" O.C. #4 AT 12" O.C. --- W1 CONCRETE 8" #4 AT 18" O.C. #4 AT 12" O.C. --- FOOTING SCHEDULE MARK LENGTH WIDTH THICKNESS REINFORCING REMARKS F30 30" 30" 10" (3) #4 EACH WAY BOTTOM --- EWF18 CONT 18" 10" (2) #4 CONT BOTTOM STRIP FOOTING WF18 CONT 18" 10" (2) #4 CONT BOTTOM STRIP FOOTING WF18A CONT 18" 10" (2) #4 CONT TOP & BOTTOM STRIP FOOTING KEYNOTES FOUNDATION PLAN NOTES A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. E. WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. F. F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. G. RWF36, RWF42, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS RETAINING WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. H. P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. I. SC1, SC2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL COLUMN. SEE STEEL COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. COLUMNS START AT THE LEVEL THEY ARE CALLED OUT ON. J. C1, C2, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE OR MASONRY COLUMN. SEE COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. K. J1, J2, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE OR MASONRY JAMB. SEE JAMB SCHEDULE FOR ADDITIONAL INFORMATION. L. CJ - AS SHOWN ON PLAN INDICATES A CONTROL JOINT IN A CONCRETE OR MASONRY WALL. SEE GENERAL STRUCTURAL NOTES AND TYPICAL DETAIL. M. PROVIDE CONTINUOUS BEARING FOR ALL POSTS AND BUILT-UP STUDS TO THE FOUNDATION PER TYPICAL "SOLID BLOCKING BETWEEN FLOORS" DETAIL. N. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. O. VERIFY EXACT SIZE AND LOCATION OF DEPRESSED AND/OR RAISED SLABS WITH ARCHITECTURAL DRAWINGS. P. FOR SIDEWALK AND LANDING LOCATIONS, SEE ARCHITECTURAL DRAWINGS. Q. VERIFY EXACT SIZE AND LOCATION OF OPENINGS IN PRECAST CONCRETE WALL PANELS WITH ARCHITECTURAL DRAWINGS. R. COLUMN FOOTING SIZES ARE PRELIMINARY SIZES TO BE VERIFIED BY STRUCTURAL ENGINEER OF RECORD TO CONSTRUCTION. PRE-ENGINEERED BUILDING MANUFACTURER SHALL SUBMIT DESIGN CALCULATIONS PRIOR TO FABRICATING BUILDING COMPONENTS. CALCULATIONS SHALL SHOW ALL FOOTING LOAD PER METAL BUILDING MANUFACTURER'S ASSOCIATION "RECOMMENDED DESIGN PRACTICES MANUAL". SCALE: 1/4" = 1'-0" FOUNDATION 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. NOTES: SHEARWALL TYPE SCHEDULE MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 5 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 6. 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 32" O.C. WOOD: 16d STAGGERED AT 4" O.C. 1 2 3 4 5 A B C D B1 B1 B1 P1 P1 1 2 3 4 5 A B C D EW J 1 WJ 1 WJ 1 5 6.6. 5 5 1 2 3 4 5 fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d St r u c t u r a l E n g i n e e r i n g Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 in f o @ f r o s t - s t r u c t u r a l . c o m RE V . DA T E B Y D E S C R I P T I O N Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n gi n e e r i n g , I n c . Le g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r in p i e c e s . I t is o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i ca l l y i d e n t i f i e d he r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r sh a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d c o n d i t i o n s a n d re p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r o m i s s i o n d i s c o v e r e d be f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . PR O J E C T M A N A G E R : C A D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : CURRENT REV. FR O S T S2.1 FI R S T F L O O R F R A M I N G P L A N Au t h o r C R A P O 1 5 6 15 6 E 2 n d S RE X B U R G , I D 83 4 4 0 CR A P O NORTH FLOOR FRAMING PLAN NOTES A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D. TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. UNO. E. PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 6'-0" OR LESS, (1) TS & (1) KS, OPENINGS 6'-1" TO 9'-0", (1) TS & (2) KS, 9'-1" TO 12-0", (2) TS & (3) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. G. WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A WOOD JOIST. SEE WOOD JOIST SCHEDULE FOR ADDITIONAL INFORMATION. H. P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. I. SC1, SC2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL COLUMN. SEE STEEL COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. COLUMNS START AT THE LEVEL THEY ARE CALLED OUT ON. J. W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. K. SL1, SL2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL LINTEL. SEE STEEL LINTEL SCHEDULE FOR ADDITIONAL INFORMATION. L. L1, L2, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE OR MASONRY LINTEL. SEE LINTEL SCHEDULE FOR ADDITIONAL INFORMATION. M. J1, J2, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE OR MASONRY JAMB. SEE JAMB SCHEDULE FOR MORE INFORMATION. N. CJ - AS SHOWN ON PLAN INDICATES A CONTROL JOINT IN A CONCRETE OR MASONRY WALL. SEE GSN AND TYPICAL DETAIL. JOINTS MAY BE SHOWN, BUT NOT NOTED ON THIS PLAN. SEE FOUNDATION PLAN FOR NOTED LOCATIONS. O. CS16, CS18, ETC. - AS SHOWN AT WALL OPENINGS, PROVIDE STRAPPING PER "TYPICAL STRAP AT OPENING" DETAIL. P. PROVIDE CONTINUOUS BEARING FOR ALL POSTS AND BUILT-UP STUDS TO THE FOUNDATION PER TYPICAL "SOLID BLOCKING BETWEEN FLOORS" DETAIL. Q. FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. R. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. S. CONTRACTOR TO VERIFY AND BE RESPONSIBLE FOR VARIATIONS IN CONCRETE QUANTITY DUE TO CAMBER, CONSTRUCTION DEAD LOAD DEFLECTIONS AND/OR STRUCTURAL STEEL TOLERANCES OF STEEL BEAMS AND STEEL DECK. T. FOR CLARITY, ALL FLOOR OPENINGS MAY NOT BE SHOWN ON THE FLOOR FRAMING PLAN. FOR EXACT SIZE, NUMBER AND LOCATION OF OPENINGS, SEE ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. FOR FRAMING AT OPENINGS, SEE TYPICAL DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. NOTES: SHEARWALL TYPE SCHEDULE MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 5 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 6. 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 32" O.C. WOOD: 16d STAGGERED AT 4" O.C. BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 1 3/4x 5 1/2 LVL B2 (2) 2x8 OR 4x8 OR (2) 1 3/4x5 1/2 LVL B3 (3) 1 3/4x11 7/8 LVL OR 3 1/2x11 7/8 LVL OR 5 1/8x13 1/2 GLB POST (P) SCHEDULE MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x4 DOUG FIR NO. 2 SEE TYPICAL DETAIL P2 (3) 2x4 DOUG FIR NO. 2 SEE TYPICAL DETAIL KEYNOTES SCALE: 1/4" = 1'-0" FIRST FLOOR 1 2 3 4 5 A B C D 1 2 3 4 5 A B C D 5 6.6. 5 5 P2 B3 B2 B2 B2 B2B2B2 B2 B2 NEW ROOF OVERBUILD EX I S T I N G R O O F F R A M I N G NE W P R E F A B R O O F T R U S S E S 1 2 3 4 5 fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d St r u c t u r a l E n g i n e e r i n g Id a h o F a l l s , I D 8 3 4 0 1 ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 in f o @ f r o s t - s t r u c t u r a l . c o m RE V . DA T E B Y D E S C R I P T I O N Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n gi n e e r i n g , I n c . Le g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r in p i e c e s . I t is o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i ca l l y i d e n t i f i e d he r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r sh a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d c o n d i t i o n s a n d re p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r o m i s s i o n d i s c o v e r e d be f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . PR O J E C T M A N A G E R : C A D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : CURRENT REV. FR O S T S2.2 RO O F F R A M I N G P L A N Au t h o r C R A P O 1 5 6 15 6 E 2 n d S RE X B U R G , I D 83 4 4 0 CR A P O NORTH POST (P) SCHEDULE MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x4 DOUG FIR NO. 2 SEE TYPICAL DETAIL P2 (3) 2x4 DOUG FIR NO. 2 SEE TYPICAL DETAIL BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 1 3/4x 5 1/2 LVL B2 (2) 2x8 OR 4x8 OR (2) 1 3/4x5 1/2 LVL B3 (3) 1 3/4x11 7/8 LVL OR 3 1/2x11 7/8 LVL OR 5 1/8x13 1/2 GLB KEYNOTES ROOF FRAMING PLAN NOTES A. VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B. ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C. IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D. TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. UNO. WHERE ROOF TRUSSES OR JOISTS SPANS EXCEED 20'-0" ALIGN ADDITIONAL STUD BELOW ROOF FRAMING MEMBER. E. PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 6'-0" OR LESS, (1) TS & (1) KS, OPENINGS 6'-1" TO 9'-0", (1) TS & (2) KS, 9'-1" TO 12-0", (2) TS & (3) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. G. WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A WOOD JOIST. SEE WOOD JOIST SCHEDULE FOR ADDITIONAL INFORMATION. H. P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. I. SC1, SC2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL COLUMN. SEE STEEL COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. COLUMNS START AT THE LEVEL THEY ARE CALLED OUT ON. J. W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. K. SL1, SL2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL LINTEL. SEE STEEL LINTEL SCHEDULE FOR ADDITIONAL INFORMATION. L. L1, L2, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE OR MASONRY LINTEL. SEE LINTEL SCHEDULE FOR ADDITIONAL INFORMATION. M. J1, J2, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE OR MASONRY JAMB. SEE JAMB SCHEDULE FOR MORE INFORMATION. N. CJ - AS SHOWN ON PLAN INDICATES A CONTROL JOINT IN A CONCRETE OR MASONRY WALL. SEE GSN AND TYPICAL DETAIL. JOINTS MAY BE SHOWN, BUT NOT NOTED ON THIS PLAN. SEE FOUNDATION PLAN FOR NOTED LOCATIONS. O. TIE EACH ROOF TRUSS AT BEARING LOCATIONS WITH (1) H2.5A OR (1) H1 CLIP, AND EACH GIRDER TRUSS WITH (2) H2.5A CLIPS, UNO. P. "D=" INDICATES DRAG LOAD (ASD) THAT TRUSS MANUFACTURER IS TO DESIGN TRUSS FOR IN BOTH TENSION AND COMPRESSION. Q. TIE EACH ROOF JOIST AT BEARING LOCATIONS WITH (1) H2.5A CLIP, UNO. R. PROVIDE BUILT-UP 2x POSTS BELOW EACH GIRDER TRUSS, MATCH GIRDER TRUSS WIDTH, U.N.O. S. OVERBUILD PONY WALLS (MAX __'-0" SPACING FOR 2x OVERBUILD FRAMING AT __" O.C. W/ SIMPSON LUS__ HANGER) PER "TYPICAL OVERBUILD" DETAIL. T. CS16, CS18, ETC. - AS SHOWN AT WALL OPENINGS, PROVIDE STRAPPING PER "TYPICAL STRAP AT OPENING" DETAIL. U. PROVIDE CONTINUOUS BEARING FOR ALL POSTS AND BUILT-UP STUDS TO THE FOUNDATION PER TYPICAL "SOLID BLOCKING BETWEEN FLOORS" DETAIL. V. FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. W. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. X. CONTRACTOR TO VERIFY AND BE RESPONSIBLE FOR VARIATIONS IN CONCRETE QUANTITY DUE TO CAMBER, CONSTRUCTION DEAD LOAD DEFLECTIONS AND/OR STRUCTURAL STEEL TOLERANCES OF STEEL BEAMS AND STEEL DECK. Y. FOR CLARITY, ALL ROOF OPENINGS MAY NOT BE SHOWN ON THE ROOF FRAMING PLAN. FOR EXACT SIZE, NUMBER AND LOCATION OF OPENINGS, SEE ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. FOR FRAMING AT OPENINGS, SEE TYPICAL DETAILS. Z. VERIFY EXACT SIZE AND WEIGHT OF EQUIPMENT ON ROOF WITH MECHANICAL DRAWINGS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. NOTES: SHEARWALL TYPE SCHEDULE MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 5 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 6. 7/16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 1/2" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5/8" Ø A.B. W/ 1/4"x3"x3" PLATE WASHERS AT 32" O.C. WOOD: 16d STAGGERED AT 4" O.C. SCALE: 1/4" = 1'-0" FIRST FLOOR FRAMING PLAN