Loading...
HomeMy WebLinkAboutPLANS - 23-00758 - 202 Pine Tree Rd - Solar PanelsDRAWN BY: SoloCAD 10/18/2023 IDAHO POWER SITE INFORMATION PAUL SORENSEN 202 PINETREE RD REXBURG, ID 83440 AC SYSTEM SIZE: 15 KW AC DC SYSTEM SIZE: 9.75 KW DC LAT, 43.7114318LONG, -111.7814476 (26) JINKO SOLAR JKM375M-60 EXISTING PV MODULES (1) SOL-ARK-15K-2P INVERTER(S) HORIZON PWR SC 589 SOUTH YELLOWSTONE HWY STE 305 REXBURG ID 83440 LICENSE# RCE-56878 CONTRACTOR INFORMATION: AERIAL VIEW: COVER - PV01 GENERAL NOTES 1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING 2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110 3.ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 5.ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS ELECTRICAL EQUIPMENT EXISTING PV MODULES: (26) JINKO SOLAR JKM375M-60 DC SYSTEM SIZE: 9.75 KW DC INVERTER(S): (1) SOL-ARK-15K-2P INVERTER(S) AC SYSTEM SIZE: 15 KW AC (1) HOMEGRID ENERGY BATTERIES APPLICABLE GOVERNING CODES 2017 NEC 2018 IRC 2018 IFC 2018 IBC OCCUPANCY: R-3 ZONING: RESIDENTIAL SITE SPECIFICATIONS STREET VIEW AERIAL VIEW PV01 COVER PV02 SITE PLAN PV03 LINE DIAGRAM PV04 ELECTRICAL CALCS PV05 LABELS PV06 PLACARD PV07 SITE PHOTOS SHEET INDEX 10/18/2023 DRAWN BY: SoloCAD SITE INFORMATION PAUL SORENSEN 202 PINETREE RD REXBURG, ID 83440 AC SYSTEM SIZE: 15 KW AC DC SYSTEM SIZE: 9.75 KW DC LAT, 43.7114318LONG, -111.7814476 (26) JINKO SOLAR JKM375M-60 EXISTING PV MODULES (1) SOL-ARK-15K-2P INVERTER(S) IDAHO POWER HORIZON PWR SC 589 SOUTH YELLOWSTONE HWY STE 305 REXBURG ID 83440 LICENSE# RCE-56878 CONTRACTOR INFORMATION: MSP M BATT INV SUB JB AC AC INV MSP M BATT INV SUB JB AC AC INV STRING 1: 13 MODULES STRING 2: 13 MODULES EQUIPMENT LEGEND: INVERTERVISIBLE, LOCKABLE, LABELED AC DISCONNECT METER SOCKET (FOR UTILITY PV METER) UTILITY METER MAIN SERVICE PANEL LC LOAD CENTER FIRE ACCESS PATHWAY (3' TYP) C INV PV AC MSP M COMBINER BOX PROPERTY LINEBATTBATTERY(IES) SUB SUB PANEL SD SERVICE DISCONNECT JB JUNCTION BOX PV MODULES SITE PLAN - PV02 ARRAY DETAILS: MOUNTING PLANE:AZIMUTH:TILT: MP1 180°22° CLOSE UP OF HOME VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 3' OF UTILITY METER 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 160'-10" 486'-6" 37'-3" 223'-6" 82'-1" 251'-6" 202 Pinetree Rd FRONT OF HOME DRIVEWAY DR I V E W A Y MP1 EXISTING PV SYSTEM TRENCHING THROUGH DIRT APPROX: 160' 18" MIN DEPTH PVC SCH40 10/18/2023 DRAWN BY: SoloCAD SITE INFORMATION PAUL SORENSEN 202 PINETREE RD REXBURG, ID 83440 AC SYSTEM SIZE: 15 KW AC DC SYSTEM SIZE: 9.75 KW DC LAT, 43.7114318LONG, -111.7814476 (26) JINKO SOLAR JKM375M-60 EXISTING PV MODULES (1) SOL-ARK-15K-2P INVERTER(S) IDAHO POWER HORIZON PWR SC 589 SOUTH YELLOWSTONE HWY STE 305 REXBURG ID 83440 LICENSE# RCE-56878 CONTRACTOR INFORMATION: AC DC UL 1741 COMPLIANT INTEGRATED RAPID SHUTDOWN DC DISCONNECT N G SOL-ARK-15K-2P NG (E) LOADS (E) LOADS (E) 200A MAIN PANEL 1 (1) HOMEGRID STACK'D 4.8 kWh kWh BATTERIES, 14.4 kWh TOTAL (E) (E) PV AC DISCONNECT 60A NON-FUSED, VISIBLE, LOCKABLE, LABELED, OPEN 240V, 2-POLE(E) STRING (2) 13 MODULES (E) STRING (1) 13 MODULES AC DC AC DC AC DC AC DC AC DC AC DC (E)(E) (E)(E) (E) NEMA 3R J-BOX NEMA 3R J-BOX NEMA 3R J-BOX 2 200A AC LOAD GEN GRID AC DC N G GRID UL 1741 COMPLIANT INTEGRATED RAPID SHUTDOWN DC DISCONNECT (E) SOLAREDGE SE3800H-US (N) 175A FUSES PV AC DISCONNECT 200A FUSED, VISIBLE, LOCKABLE, LABELED, OPEN 240V, 2-POLE 1 (N) GROUNDING ELECTRODE 120/240 VAC TO UTILITY GRID (E)UTILITY METER (E) (E) 200A-2P CONDUIT & CONDUCTOR SCHEDULE TAG QTY WIRE GAUGE DESCRIPTION CONDUIT SIZE 1 (3)4/0 AWG THHN/THWN-2 COPPER - (L1, L2, NEUTRAL) (1)6 AWG THWN-2 COPPER - (GROUND) (3)2 AWG THHN/THWN-2 COPPER - (L1, L2, NEUTRAL) (1)8 AWG THWN-2 COPPER - (GROUND) ()0 (1)0 (3) (1) (3)0 (1)0 (3)0 (1)0 (3)0 (1)0 (3)0 (1)0 2" EMT 1.5" PVC-402 3 4 5 6 7 VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 3' OF UTILITY METER LINE DIAGRAM - PV03 TYPE QTY DESCRIPTION RATING EQUIPMENT SCHEDULE 1-PHASE, 60 HZ, UL 1741 LISTED POWER MAX (PMAX): OPEN CIRCUIT VOLTAGE (VOC): MAX POWER-POINT CURRENT (IMP): MAX POWER-POINT VOLTAGE (VMP): SHORT CIRCUIT CURRENT (ISC): SERIES FUSE RATING: JINKO SOLAR JKM375M-60 SPECS 375 W 41.12 V 10.86 A 34.53 V 11.59 A 20A SOL-ARK-15K-2P SPECS MAX INPUT VOLTAGE:500 V MAX INPUT CURRENT:26 A NOMINAL DC INPUT VOLTAGE:240 V MAXIMUM OUTPUT POWER:15000 W NOM. OUTPUT VOLTAGE:240 V MAX OUTPUT CURRENT:62.5 A (E) MODULES:(26)JINKO SOLAR JKM375M-60 375 W INVERTERS:(1)SOL-ARK-15K-2P 15000 W AC DISCONNECT(S):(1)PV AC DISCONNECT, 240V, 2-POLE 200 A ENERGY STORAGE:(1)HOMEGRID ENERGY 4.8 kWh TRENCHING THROUGH DIRT APPROX: 160' 18" MIN DEPTH PVC SCH40 EXISTING SYSTEM WILL NEED TO BE TRENCHED FROM GARAGE TO THE SOL-ARK-15K-2P INVERTER SOLADECK JUNCTION BOX UL50 TYPE 3R SEC #2/0 AWG Copper Cable Class K 600 V Per NEC 400.4 2 10/18/2023 DRAWN BY: SoloCAD SITE INFORMATION PAUL SORENSEN 202 PINETREE RD REXBURG, ID 83440 AC SYSTEM SIZE: 15 KW AC DC SYSTEM SIZE: 9.75 KW DC LAT, 43.7114318LONG, -111.7814476 (26) JINKO SOLAR JKM375M-60 EXISTING PV MODULES (1) SOL-ARK-15K-2P INVERTER(S) IDAHO POWER HORIZON PWR SC 589 SOUTH YELLOWSTONE HWY STE 305 REXBURG ID 83440 LICENSE# RCE-56878 CONTRACTOR INFORMATION: INVERTER MODEL(S):SOL-ARK-15K-2P # OF INVERTERS:1 MAX OUTPUT CURRENT:62.5A (# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING (1 X 62.5A X 1.25) = 78A <= 80A, OK NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES 4-6 .80 7-9 .70 10-20 .50 ELECTRICAL CALCS - PV04 CONDUIT & CONDUCTOR SCHEDULE TAG QTY WIRE GAUGE DESCRIPTION CONDUIT SIZE CONDUCTOR RATING CONDUCTOR TEMP. RATE AMBIENT TEMP TEMP. DERATE # OF CONDUCTORS DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL (3)4/0 AWG THHN/THWN-2 COPPER - (L1, L2, NEUTRAL) (1)6 AWG THWN-2 COPPER - (GROUND) (3)2 AWG THHN/THWN-2 COPPER - (L1, L2, NEUTRAL) (1)8 AWG THWN-2 COPPER - (GROUND) ()0 (1)0 (3) (1) (3)0 (1)0 (3)0 (1)0 (3)0 (1)0 (3)0 (1)0 2" EMT 1.5" PVC-40 1 2 3 4 5 6 7 8 230A 75°C 33°C 0.94 1 216.2A 30.4% 115A 75°C 33°C 0.94 1 108.1A 19.3% 75°C 33°C 0.94 75°C 33°C 0.94 1 75°C 1 75°C 1 75°C 1 75°C 1 GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. INTERCONNECTION NOTES: DISCONNECT NOTES: 1. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95] 2. SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC 705.12] WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH [NEC 240.21] 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH. 3. FUSED AC DISCONNECT TO BE USED. SYSTEM OCPD CALCULATIONS INTERCEPTING CONDUCTORS MAIN BUSBAR RATING:200A MAIN DISCONNECT RATING:200A PV OCPD RATING:80A SERVICE RATING >= PV OCPD 200A >= 80A, OK 2 10/18/2023 DRAWN BY: SoloCAD SITE INFORMATION PAUL SORENSEN 202 PINETREE RD REXBURG, ID 83440 AC SYSTEM SIZE: 15 KW AC DC SYSTEM SIZE: 9.75 KW DC LAT, 43.7114318LONG, -111.7814476 (26) JINKO SOLAR JKM375M-60 EXISTING PV MODULES (1) SOL-ARK-15K-2P INVERTER(S) IDAHO POWER HORIZON PWR SC 589 SOUTH YELLOWSTONE HWY STE 305 REXBURG ID 83440 LICENSE# RCE-56878 CONTRACTOR INFORMATION: LABELS - PV05 LABEL 5 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS. [NEC 690.54] LABEL 6 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)(3&4)] LABEL 7 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)(A)] LABEL 1 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [NEC 690.13(B)] LABELING NOTES: 1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2.LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] 5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [NEC 690.31(G)] LABEL 3 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(b)] WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION !WARNING WARNING! DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: ELECTRIC SHOCK HAZARD INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING: PHOTOVOLTAIC POWER SOURCE TURN RAPID SHUTDOWN SWICH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL 4 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES [NEC 705.12(B)(3)] 63 240 EXISTING SUB PANEL (ONLY IF WHERE POINT OF INTERCONNECTION IS MADE) **ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ELECTRICAL DIAGRAM PAGE. ** JUNCTION BOX MAIN SERVICE PANEL AC DISCONNECT PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUT CIRCUITS OR INVERTER (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) (ONLY IF PV INTERCONNECTION CONSISTS OF LOAD SIDE BREAKER) LABELING DIAGRAM: 1 3 4 5 3 4 5 115 4 1 8 3 6 6 7 LABEL 2 EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES.[NEC 705.12(B)(2)(3)(c)] !WARNING THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. 2 2 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL 8 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. MAXIMUM VOLTAGE: MAXIMUM CIRCUIT CURRENT: MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC TO DC CONVERTER (IF INSTALLED) : LABEL 9 AT EACH DC DISCONNECTING MEANS [NEC 690.53] 15 26 500 9 MSP M BATT INV SUB JB AC AC INV 10/18/2023 DRAWN BY: SoloCAD SITE INFORMATION PAUL SORENSEN 202 PINETREE RD REXBURG, ID 83440 AC SYSTEM SIZE: 15 KW AC DC SYSTEM SIZE: 9.75 KW DC LAT, 43.7114318LONG, -111.7814476 (26) JINKO SOLAR JKM375M-60 EXISTING PV MODULES (1) SOL-ARK-15K-2P INVERTER(S) IDAHO POWER HORIZON PWR SC 589 SOUTH YELLOWSTONE HWY STE 305 REXBURG ID 83440 LICENSE# RCE-56878 CONTRACTOR INFORMATION: CAUTION 202 Pinetree Rd, Rexburg ID 83440 PLACARD - PV06 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: DIRECTORY: PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10] SUB PANEL (E) INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH FRONT OF HOME (E) AC DISCONNECT EXISTING PV SYSTEM MAIN DISTRIBUTION UTILITY DISCONNECT INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH AC DISCONNECT BATTERY(IES) 10/18/2023 DRAWN BY: SoloCAD SITE INFORMATION PAUL SORENSEN 202 PINETREE RD REXBURG, ID 83440 AC SYSTEM SIZE: 15 KW AC DC SYSTEM SIZE: 9.75 KW DC LAT, 43.7114318LONG, -111.7814476 (26) JINKO SOLAR JKM375M-60 EXISTING PV MODULES (1) SOL-ARK-15K-2P INVERTER(S) IDAHO POWER HORIZON PWR SC 589 SOUTH YELLOWSTONE HWY STE 305 REXBURG ID 83440 LICENSE# RCE-56878 CONTRACTOR INFORMATION: SITE PHOTOS: SITE PHOTOS - PV07  ^ŽůĂƌ/ŶƉƵƚWŽǁĞƌϭϵ͕ϱϬϬt DĂdžůůŽǁĞĚWsWŽǁĞƌ ϭϵ͕ϱϬϬt DĂdžWsWŽǁĞƌĞůŝǀĞƌĞĚƚŽĂƩĞƌLJΘ KƵƚƉƵƚƐ ϭϱ͕ϬϬϬt DĂdžsŽůƚĂŐĞ;sŽĐͿ ϱϬϬsΛϮϲ DWWdsŽůƚĂŐĞZĂŶŐĞ ϭϮϱ-ϰϮϱs ^ƚĂƌƟŶŐsŽůƚĂŐĞ ϭϮϱs EƵŵďĞƌŽĨDWWd ϯ DĂdž^ŽůĂƌ^ƚƌŝŶŐƐWĞƌDWWd Ϯ DĂdžƵƌƌĞŶƚƉĞƌDWWd;^ĞůĨ>ŝŵͲ ŝƟŶŐͿ Ϯϲ DĂdžŽƵƉůĞĚ/ŶƉƵƚ;DŝĐƌŽͬ^ƚƌŝŶŐ /ŶǀĞƌƚĞƌƐͿ ϭϵ͕ϮϬϬt KƵƚƉƵƚWŽǁĞƌϭϱŬtKŶ-'ƌŝĚΘKī-'ƌŝĚ ŽŶŶĞĐƟŽŶƐ ϭϮϬͬϮϰϬͬϮϬϴs^ƉůŝƚWŚĂƐĞ ŽŶƟŶƵŽƵƐWŽǁĞƌƚŽ'ƌŝĚ;KŶ-'ƌŝĚͿ ϭϱ͕ϬϬϬtϲϮ͘ϱ->;ϮϰϬsͿ ŽŶƟŶƵŽƵƐWŽǁĞƌƚŽ>ŽĂĚ;Kī- 'ƌŝĚͿ ϭϮ͕ϬϬϬtϱϬ->;ϮϰϬsͿ ^ƵƌŐĞWŽǁĞƌϭϬƐĞĐ ^ƵƌŐĞWŽǁĞƌϭϬϬŵƐ Ϯϰ͕ϬϬϬs>->;ϮϰϬsͿ ϯϬ͕ϬϬϬs>->;ϮϰϬsͿ WĂƌĂůůĞů^ƚĂĐŬŝŶŐ zĞƐ-hƉƚŽϭϮ &ƌĞƋƵĞŶĐLJ ϲϬͬϱϬ,nj ŽŶƟŶƵŽƵƐWŽǁĞƌǁŝƚŚ'ƌŝĚŽƌ 'ĞŶĞƌĂƚŽƌ ϰϴ͕ϬϬϬtϮϬϬ>->;ϮϰϬsͿ Ϯϰ͕ϬϬϬtϮϬϬ>-E;ϭϮϬsͿ ĸĐŝĞŶĐLJ ϵϲ͘ϱй;WĞĂŬϵϳ͘ϱйͿ /ĚůĞŽŶƐƵŵƉƟŽŶdLJƉŝĐĂů—EŽ>ŽĂĚ ϵϬt ^ĞůůĂĐŬWŽǁĞƌDŽĚĞƐ >ŝŵŝƚĞĚƚŽ,ŽƵƐĞŚŽůĚͬ&ƵůůLJ 'ƌŝĚ-dŝĞĚ ĞƐŝŐŶ;ƚŽͿ dƌĂŶƐĨŽƌŵĞƌůĞƐƐ ZĞƐƉŽŶƐĞdŝŵĞ;'ƌŝĚ-dŝĞĚƚŽKī-'ƌŝĚͿ ϱŵƐ WŽǁĞƌ&ĂĐƚŽƌ нͬ-Ϭ͘ϵ-ϭ͘Ϭ ĂƩĞƌLJ;ŽƉƟŽŶĂůͿKƵƚƉƵƚWŽǁĞƌϭϮ͕ϬϬϬt ŝŵĞŶƐŝŽŶƐ;,džtdžͿ ϯϭ͘ϴ͟džϭϴ͘ϯ͟dž ϭϬ͘ϵ͟ tĞŝŐŚƚ;ƉĂĐŬĂŐĞͿ ϭϯϱůďƐ ŶĐůŽƐƵƌĞ /WϲϱͬEDϯZ ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ -ϰϬΕϲϬΣ͕хϰϱΣ ĞƌĂƟŶŐ /ŶƐƚĂůůĂƟŽŶ^ƚLJůĞ tĂůů-DŽƵŶƚĞĚ tŝ-&ŝΘ>EŽŵŵƵŶŝĐĂƟŽŶ /ŶĐůƵĚĞĚ ^ƚĂŶĚĂƌĚtĂƌƌĂŶƚLJ;ǀĞƌŝĮĞĚďLJ,>ddĞƐƟŶŐͿ ϭϬzĞĂƌƐ 'ĞŶĞƌĂů dLJƉĞ >ĞĂĚ-ĐŝĚŽƌ>ŝ-/ŽŶ EŽŵŝŶĂů/ŶƉƵƚ ϰϴs ĂƉĂĐŝƚLJ ϱϬ—ϵϵϬϬŚ sŽůƚĂŐĞZĂŶŐĞ ϰϯ͘Ϭ—ϲϯ͘Ϭs ŽŶƟŶƵŽƵƐĂƩĞƌLJŚĂƌŐŝŶŐKƵƚƉƵƚ Ϯϳϱ ŚĂƌŐŝŶŐƵƌǀĞ ϯ-^ƚĂŐĞǁͬƋƵĂůŝnjĂƟŽŶ 'ƌŝĚƚŽĂƩŚĂƌŐŝŶŐĸĐŝĞŶĐLJ ϵϲ͘Ϭй džƚĞƌŶĂůdĞŵƉĞƌĂƚƵƌĞ^ĞŶƐŽƌ /ŶĐůƵĚĞĚ ƵƌƌĞŶƚ^ŚƵŶƚĨŽƌĐĐƵƌĂƚĞй^K /ŶƚĞŐƌĂƚĞĚ džƚĞƌŶĂů'ĞŶ^ƚĂƌƚĂƐĞĚŽŶsŽůƚĂŐĞ Žƌй^K /ŶƚĞŐƌĂƚĞĚ ŽŵŵƵŶŝĐĂƟŽŶƚŽ>ŝƚŚŝƵŵĂƩĞƌLJ ĂŶƵƐΘZ^ϰϴϱ WƌŽƚĞĐƟŽŶƐΘĞƌƟĮĐĂƟŽŶƐ ůĞĐƚƌŽŶŝĐƐĞƌƟĮĞĚ^ĂĨĞƚLJďLJ^'^>ĂďƐƚŽE Θh>^ƉĞĐƐ-EϲϵϬ͘ϰΘEϳϬϱ͘ϰͬϲ zĞƐ 'ƌŝĚ^ĞůůĂĐŬ—h>ϭϳϰϭ-ϮϬϭϬͬϮϬϭϴ͕/Ͳ ϭϱϰϳĂ-ϮϬϬϯͬϮϬϭϰ͕&ϭϱůĂƐƐ͕h>ϭϳϰϭ^͕ ZƵůĞϮϭ͕,KZƵůĞϭϰ, zĞƐ WsŝƐĐŽŶŶĞĐƚ^ǁŝƚĐŚ—EϮϰϬ͘ϭϱ /ŶƚĞŐƌĂƚĞĚ 'ƌŽƵŶĚ&ĂƵůƚĞƚĞĐƟŽŶ—EϲϵϬ͘ϱ /ŶƚĞŐƌĂƚĞĚ WsZĂƉŝĚ^ŚƵƚĚŽǁŶŽŶƚƌŽů—EϲϵϬ͘ϭϮ /ŶƚĞŐƌĂƚĞĚ WsƌĐ&ĂƵůƚĞƚĞĐƟŽŶ—EϲϵϬ͘ϭϭ /ŶƚĞŐƌĂƚĞĚ Ws/ŶƉƵƚ>ŝŐŚƚŶŝŶŐWƌŽƚĞĐƟŽŶ /ŶƚĞŐƌĂƚĞĚ Ws^ƚƌŝŶŐ/ŶƉƵƚZĞǀĞƌƐĞWŽůĂƌŝƚLJWƌŽƚĞĐƟŽŶ /ŶƚĞŐƌĂƚĞĚ KƵƚƉƵƚƌĞĂŬĞƌƐ-ϮϬϬ /ŶƚĞŐƌĂƚĞĚ ϮϬϬdžϮĂƩĞƌLJƌĞĂŬĞƌͬŝƐĐŽŶŶĞĐƚ /ŶƚĞŐƌĂƚĞĚ ^ƵƌŐĞWƌŽƚĞĐƟŽŶ dLJƉĞ//ͬdLJƉĞ // ̇̋_-̈— ¢ſĎā΅¢ĮĎĎƖ