Loading...
HomeMy WebLinkAboutPLANS - 23-00722 - Jensen Storage Bldg - 10 Units40 ' - 0 " UNIT 1 UNIT 2 UNIT3 UNIT 4 UNIT 5 UNIT 6 UNIT 7 UNIT 8 UNIT 9 UNIT 10 1 A1 1D 2D 3D 4D 5D 6D 7D 8D 9D 10D 11D 40 ' - 0 " 12x12 OVERHEAD DOOR (TYP) 12x12 OVERHEAD DOOR (TYP) 7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0"7' - 0" TYP. 14' - 0" TYP. 14' - 0" TYP. 14' - 0" TYP. 14' - 0" TYP. 14' - 0" TYP. 14' - 0" TYP. 14' - 0" TYP. 14' - 0" TYP. 14' - 0" TYP. 14' - 0" 10 Bys @ 14' - 0" = 140' - 0" T.O. CONC. FLOOR 100' -0" T.O. WALL 112' -0" 5/8" 12" 12 ' - 0 " 12x12 OVERHEAD DOOR (TYP) A1 2 T.O. CONC. FLOOR 100' -0" T.O. WALL 112' -0" BOTTOM PLATESLAB ON GRADE METAL SKIN DBL TOP PLATE (SEE STRUCT. DWG) EDGE PURLINS (SEE FRAMING PLAN) METAL ROOFING 2x ROOF PURLINS (SEE FRAMING PLAN) ANCHOR BOLT (SEE STRUCT DWG'S) 2' - 8 " M I N . TH I S D R A W I N G I S P R O P E R T Y O F T E T O N D R A F T I N G SE R V I C E S I T I S N O T T O B E R E P R O D U C E D O R T O B E US E D F O R A N Y C O N S T R U C T I O N E X C E P T A S H E R E I N IN D I C A T E D W I T H O U T T H E E X P R E S S W R I T T E N C O N S E N T . TE T O N D R A F T I N G S E R V I C E S A S S U M E S N O L I A B I L I T Y BE Y O N D T H E P R O D U C T I O N O F T H E S E P R I N T S . A L L IN F O R M A T I O N C O N T A I N E D H A V E B E E N E X C L U S I V E L Y PR O V I D E D B Y T H E C U S T O M E R A N D H A V E B E E N AC C E P T E D A S I S . DA T E : CH E C K E D B Y : DR A W N B Y : DA T E RE V I S I O N S BY TE T O N DR A F T I N G S E R V I C E S 13 6 S O U T H S T A T E S T R E E T SH E L L E Y , I D A H O 8 3 2 7 4 PH O N E ( 2 0 8 ) -35 7 -24 2 0 FA X ( 2 0 8 ) -35 7 -24 1 9 PROJECT NO. SHEET NO. OF EV B PRELIMINARY NOT FOR CONSTRUCTION JE N S E N G R E G O R Y C O M M E R C I A L S I L V E R T I P BU S I N E S S P A R K L O T 8 223216 A1 MA D I S O N C O U N T Y , I D A H O TWO CS 9/ 2 7 / 2 3 1/8" = 1'-0" FIRST FLOOR PLAN SECTION DO NOT SCALEA1 1 SECTION DO NOT SCALEA1 2 T.O. CONC. FLOOR 100' -0" T.O. WALL 112' -0"2' - 0 " T.O. CONC. FLOOR 100' -0" T.O. WALL 112' -0" T.O. CONC. FLOOR 100' -0" T.O. WALL 112' -0" 5/8" 12" T.O. CONC. FLOOR 100' -0" T.O. WALL 112' -0" 5/8" 12" TH I S D R A W I N G I S P R O P E R T Y O F T E T O N D R A F T I N G SE R V I C E S I T I S N O T T O B E R E P R O D U C E D O R T O B E US E D F O R A N Y C O N S T R U C T I O N E X C E P T A S H E R E I N IN D I C A T E D W I T H O U T T H E E X P R E S S W R I T T E N C O N S E N T . TE T O N D R A F T I N G S E R V I C E S A S S U M E S N O L I A B I L I T Y BE Y O N D T H E P R O D U C T I O N O F T H E S E P R I N T S . A L L IN F O R M A T I O N C O N T A I N E D H A V E B E E N E X C L U S I V E L Y PR O V I D E D B Y T H E C U S T O M E R A N D H A V E B E E N AC C E P T E D A S I S . DA T E : CH E C K E D B Y : DR A W N B Y : DA T E RE V I S I O N S BY TE T O N DR A F T I N G S E R V I C E S 13 6 S O U T H S T A T E S T R E E T SH E L L E Y , I D A H O 8 3 2 7 4 PH O N E ( 2 0 8 ) -35 7 -24 2 0 FA X ( 2 0 8 ) -35 7 -24 1 9 PROJECT NO. SHEET NO. OF EV B PRELIMINARY NOT FOR CONSTRUCTION JE N S E N G R E G O R Y C O M M E R C I A L S I L V E R T I P BU S I N E S S P A R K L O T 8 223216 A2 MA D I S O N C O U N T Y , I D A H O TWO CS 9/ 2 7 / 2 3 1/8" = 1'-0" Front Elevation 1/8" = 1'-0" Rear Elevation 1/8" = 1'-0" Left Elevation 1/8" = 1'-0" Right Elevation 2x PRESSURE TREATED PLATE WALL SHEATHING OR METAL SKIN @ BACKWALL (SEE NAILING SCHED) WALL FRAMING (SEE FRAMING PLAN) GRADE 0' - 5 " M I N . #4 x 24" @ 2'-0" O.C. 24" 2' - 8 " M I N . 0' - 6" 6" CONC. WALL W/ #4 @ 24" O.C. VERTICAL 3" C L R . #4 TOP AND BOTTOM OF WALL 180° HOOK ANCHOR BOLT (SEE SCHED) 1' - 0"(2) #4 LONGIT CONCRETE SLAB ON GRADE ANCHOR BOLTS (SEE SCHED) 2x PRESSURE TREATED SILL PLATE 2x WOOD STUD WALL (SEE FRAMING PLAN) 0' - 8 " . 1' - 0".3" C L R . WALL SHEATHING (SEE SHEAR WALL SCHED.) 0' - 4 " (2) #4 LONGIT. 2x WOOD STUD WALL (SEE FRAMING PLAN) WALL SHEATHING (SEE SHEAR WALL SCHED.) DBL TOP PLATE (SEE SPLICE DETAIL) 29 GA. ROOF DECK (SEE FRAMING PLAN) 2x ROOF PURLINS (SEE FRAMING PLAN) BLOCKING SIMPSON H2.5A HANGER @ EACH PURLIN (TYP. @ SHEAR WALLS ONLY) REBAR LAP SPLICE SCHEDULE TYP. SPLICES BAR SIZE NO. DIA. f'c = 3000 PSI LENGTH (L) 4 0.500 22" 5 6 0.625 0.750 28" 33" L STANDARD HOOK DETAILS 180° HOOK DIMMENSIONS BAR SIZE A J D LE #4 6" 4" 3"2 1/2" #5 7" 5"3 3/4" 2 1/2" #6 8" 6"4 1/2"3" 90° HOOK DIMMENSIONS BAR SIZE A D LE #4 8" 3" 6" #5 10"3 3/4" 7 1/2" #6 1'-0" 4 1/2"9" A J LE Ddb A db LE D UNBLOCKED DIAPHRAGM NAILING ROOF RAFTERS/TRUSS OR FLOOR JOISTS INTERMEDIATE SUPPORTS (SEE NIALING SCHED.) SHEAR WALL OR BUILDING EDGE UNBLOCKED EDGE DIAPHRAGM BOUNDARY (SEE NAILING SCHED.) SUPPORTED PANEL EDGES (SEE NAILING SCHED.) WOOD PANEL CONTINUOUS PANEL JOINT METAL ROOF DIAPHRAGM ROOF PURLINS DIAPHRAGM BOUNDARY #10 SCREWS @ 4 1/2" O.C. 29 GA. (MIN.) METAL PANEL PANEL JOINT #10 SCREWS @ 9" O.C. @ WALL #10 SCREWS @ 9" O.C. @ EA. PURLIN EAVE PURLIN WALL 4 S1 TYP5 S1 SIDE LAP FASTENERS #10 @ 15" O.C. INTERIOR SHEARWALL (SEE PLAN) 2x WOOD STUD WALL (SEE FRAMING PLAN)WALL SHEATHING (SEE SHEAR WALL SCHED.) DBL TOP PLATE (SEE SPLICE DETAIL) 29 GA. ROOF DECK (SEE FRAMING PLAN) 2x ROOF PURLINS (SEE FRAMING PLAN) BLOCKING SIMPSON H2.5A HANGER @ EACH PURLIN #10 SCREWS @ 4 1/2" O.C. 2x WALL GIRTS @ 2' - 0" O.C. DBL TOP PLATE (SEE SPLICE DETAIL) 2x ROOF PURLINS (SEE FRAMING PLAN) 29 GA. ROOF DECK (SEE FRAMING PLAN) BLOCKING EDGE PURLIN METAL SKIN #10 SCREWS @ 4 1/2" O.C. 2x PRESSURE TREATED PLATE WALL SHEATHING (SEE NAILING SCHED) WALL FRAMING (SEE FRAMING PLAN) 0' - 5 " M I N . 0' - 8 " 1' - 0" 0' - 7 1/4" GRADE (2) #4 LONGIT #4 x 24" @ 2'-0" O.C. 24" 2' - 8 " M I N . 0' - 1 1 / 2 " 0' - 6" CONC. SLAB ON GRADE 3" C L R . 6" CONC. WALL W/ #4 @ 24" O.C. VERTICAL #4 TOP AND BOTTOM OF WALL 180° HOOK 0' - 5 " M I N . 0' - 8 " 1' - 0" 0' - 7 1/4" GRADE (2) #4 LONGIT #4 x 24" @ 2'-0" O.C. 24" 2' - 8 " M I N . 0' - 1 1 / 2 " 0' - 6" CONC. SLAB ON GRADE 3" C L R . 6" CONC. WALL W/ #4 @ 24" O.C. VERTICAL #4 TOP AND BOTTOM OF WALL 180° HOOK ANCHOR BOLT (SEE SCHED.) 2x WOOD STUD WALL (SEE FRAMING PLAN) DBL TOP PLATE (SEE SPLICE DETAIL) 2x ROOF PURLINS (SEE FRAMING PLAN) 29 GA. ROOF DECK (SEE FRAMING PLAN) BLOCKING EDGE PURLIN WALL SHEATHING (SEE NAILING SCHED.) #10 SCREWS @ 4 1/2" O.C. SPLICE DETAIL JOIST SPACEFLOOR OR ROOF LINE (2) 16D NAILS @ 4" O.C. DBL TOP PLATE CHORD MEMBER 4' - 0" MIN. LAP GENERAL STRUCTURAL NOTES (DRAWING NOTES) A. CODES AND SPECIFICATIONS 1. International Building Code (IBC) - 2018 Edition 2. ACI 318-14 Building Code Requirements for Reinforced Concrete 3. ANSI/AF&PA National Design Specification (NDS) & Suppl. for Wood Const. - 2018 Edition 4. ASCE 7-10 Min. Design Loads for Buildings and other Structures. B. DESIGN LOADS UNIFORM (PSF) 1. Roof Loads a. Live Load 20 PSF b. Snow Load Design Snow Load 35 PSF Flat Roof Snow Load Pf = 42 Ce = 1.0; Ct = 1.20; Is = 1.0 Ground Snow Load 50.0 Sloped Roof Ps = 42 Cs = 1.0 2. Lateral Loads a. Wind Load 115 MPH (3 Sec Gust) Risk Cat= II; EXP = C Encl. Cat. - Partially Enclosed Building Internal Pressure Coef. +/- 0.55 Components & Cladding = 12.3 PSF b. Seismic Load: Risk Cat: II Importance Factor = 1.0 Ss = 38.50% G; S1 = 14.40% G Site Class = D Sds = 0.383; Sd1 = 0.222 Seismic Design Category = D Basic Seismic System = Bearing wall System Design Base Shear V = 0.059 W Seismic Response Coef. Cs = 0.059 Response Modification Factor R = 6.5 Analysis Procedure = Equivalent Lateral - Force Analysis C.FOUNDATIONS 1. Bearing pressure taken as 2000 PSF for column and wall footings, based on a sandy gravel and/or gravel (Table 1806.2, Class of Materials #4). Notify Engineer if conditions encountered are different. 2. Bear footing on same type of undisturbed soil or rock throughout the entire structure. D. MATERIALS 1. Dimensional Lumber #2 Douglas Fir 2. Concrete f'c - Ftgs, Floors 4500 PSI Exposure Class = F1 Air Content 6% - Max Water-Cement Ratio 0.55 - Max Aggregrate size 3/4" 3. Reinforcing Steel ASTM A615 - Grade 60 4. Anchor Bolts A36 / F1554 GRADE 36 E. REINFORCED CONCRETE 1. Concrete shall be of ready mix type conforming to ASTM C94. 2. Portland Cement to comply with ASTM C150 3. Comply with ACI 306 Cold Weather Concrete standards if the mean daily temperature is expected to drop below 40° F for 3 or more successive days. Place no concrete against frozen earth. 4. Comply with ACI 305 Hot Weather Concrete Standards. 5. Conduct all compression tests according to ACI Standard Recommended Practice for Evaluation of Compression Test Results of Field Concrete (ACI 214) 6. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in lengths not to exceed 20 feet in any direction. 7. All construction joints shall be located so as not to impair the strength of the structure. Unless noted on the drawings, all reinforcement shall be continuous through the joints. Each construction joint shall be keyed. 8. No aluminum products shall be embedded in the concrete. Electrical conduit shall be placed at mid-height of the slabs and shall have an O.D. less that one-third the slab thickness. F. REINFORCING STEEL 1. All detailing, fabrication and placing of reinforcing bars shall conform to the ACI Manual of Standard Practice for Detailing Reinforced Concrete Structures (ACI 315). All reinforcement to be supported in the forms and space with wire or plastic bar supports. Reinforcement in footings shall be supported on precast concrete block supports conforming to the Concrete Reinforcing Steel Institute Manual of Standard Practice. 2. Splice of reinforcement at points of maximum stress shall be avoided wherever possible. See Table. 3. All continuous reinforcement shall terminate with 90 degree return or hook or separate corner bar. 4. All vertical reinforcement in columns and walls shall be doweled from the footing or structure below with rebar of the same size and spacing as required above. 5. Minimum concrete cover for reinforcing bars shall be as specified in Building Code Requirements for Reinforced Concrete (ACI 318) 6. Welding or tack welding of reinforcing bars is prohibited unless specifically approved by the Engineer. G. LUMBER 1. Do not notch any structural wood member unless shown on the drawings. 2. All nails shall be common wire nails. Any nails exposed to weather or moisture shall be of stainless steel or shall be galvanized. 3. Nailing to conform to IBC Table 2304.9.1 unless noted otherwise (See Nailing Schedule). 4. Wherever possible nails should be driven perpendicular to the grain instead of toe nail. 5. Where wood tends to split, holes for nails shall be bored a diameter smaller that of the nails. 6. Plywood face grain must be perpendicular to its supports. 7. Any wood members in contact with concrete or earth shall be pressure-treated wood or wood that is decay resistant (redwood or cedar). NAILING SCHEDULE SHEAR WALLS See Shear Wall Schedule GENERAL NOTES 1. Adequate shoring and bracing of all structural members during construction shall be provided. 2. Any proposed field changes shall have prior approval from the Engineer. 3. Contractor shall verify all dimensions in the field. Any variation from the drawings shall be brought to the attention of the Engineer. 4. Install Simpson hardware as per Manufacturers requirements. 5. Details are representations/ depictions only. Follow written callouts. 6. NO CHANGES PERMITTED WITHOUT EXPRESS WRITTEN PERMISSION OF ENGINEER STAPLES (7/16" MIN. CROWN) STUD SPACING A INTERMEDIATE NAILING (FIELD) NAILS MINIMUM PANEL THICKNESS 16" O.C.7/16" FASTNERS - FIELD NAILING 8d @ 12" O.C. 8" O.C. 24" O.C.7/16"8d @ 6" O.C.4" O.C. 24" O.C.15/32" 8d @ 12" O.C. 8" O.C. STAPLES (7/16" MIN. CROWN) WALL STUDSGRADE SHEAR WALL SCHEDULE 1 MARK WOOD PANEL SHEATHING BOLT ØNAILSMINIMUM NOMINAL THICKNESS APA RATED 7/16" FASTNERS - EDGE NAILING C 8d @ 6" O.C. 1 1/2" 16 GA. @ 4" O.C. FRAMING MEMBER SIZE 2x SILL PLATE (P.T.) 2x ANCHOR BOLTS 1/2" SPACING 4'-0" SHEAR WALL EMBED. (hef) 7" # OF LAYERS 1 1 A. SEE INTERMEDIATE NAILING SCHED NOTES: 1. NAILS TO BE COMMON OR GALV. BOX NAILS ONLY. (GALV. NAILS MUST BE HOT DIPPED OR TUMBLED). NON-GALV. BOX NAILS, SINKERS, ETC. ARE NOT ALLOWED. 2. FOUNDATION SILL PLATE SHALL BE ATTACHED PER DETAIL 3. ALL WALLS TO BE U.N.O. 4. ALL ANCHOR BOLTS TO BE A36/F1554 GRADE 36 (SEE NOTE 1) WIND COMPONENT AND CLADDING SCHEDULE WIND PRESSURE (PSF)10 SF +10.4, -27.7 50 SF 100 SF ROOF AT LEAST 8'-0" AWAY FROM ANY EDGE +10.0, -24.1 +10.0, -22.6 +10.4, -46.1ROOF WITHIN 8'-0" OF ANY EDGE +10.0, -37.0 +10.0, -33.1 +1.45, -1.54WALL AT LEAST 4' -0" AWAY FROM ANY CORNER +16.5, -14.1 +1.45, -1.81WALL WITHIN 4' -0" OF ANY CORNER +16.5 -16.2 +15.9, -18.3 +15.9 -17.0 TH I S D R A W I N G I S T H E PR O P E R T Y O F T S E E N G I N E E R S , IT I S N O T T O B E R E P R O D U C E D OR T O B E U S E D F O R A N Y CO N S T R U C T I O N E X C E P T A S HE R E I N I N D I C A T E D W I T H O U T TH E E X P R E S S W R I T T E N CO N S E N T O F T S E E N G I N E E R S CH E C K E D B Y : EV B DR A W N B Y : DA T E RE V I S I O N S BY 13 6 S O U T H S T A T E S T R E E T SH E L L E Y , I D A H O 8 3 2 7 4 PH O N E ( 2 0 8 ) -35 7 -24 2 0 FA X ( 2 0 8 ) -35 7 -24 1 9 of f i c e @ t e t o n e n g . c o m PROJECT NO. SHEET NO. OF CO P Y R I G H T @ T S E E N G I N E E R S 2 0 2 3 o f f i c e @ t e t o n e n g . c o m DA T E : PRELIMINARY NOT FOR CONSTRUCTION T S E EN G I N E E R S BU S I N E S S P A R K L O T 8 JE N S E N G R E G O R Y C O M M E R C I A L S I L V E R T I P MA D I S O N C O U N T Y , I D A H O 223216 S1 09 / 2 6 / 2 3 TWO CS SECTION DO NOT SCALES1 2 SECTION DO NOT SCALES1 3 SECTION DO NOT SCALES1 4 SECTION DO NOT SCALES1 A SECTION DO NOT SCALES1 B SECTION DO NOT SCALES1 5 SECTION DO NOT SCALES1 6 SECTION DO NOT SCALES1 1SECTION DO NOT SCALES1 7 SECTION DO NOT SCALES1 C 12'-0" x 12'-0" OVERHEAD DOOR 1D 2D 3D 4D 5D 6D 7D 8D 9D 10D 11D 8x12 SHOVEL FOOTING W/ (2) #4 LONGIT (TYP) 8x12 FOOTING W/ (2) #4 LONGIT (TYP) 8x12 FOOTING W/ (2) #4 LONGIT (TYP) 8x12 FOOTING W/ (2) #4 LONGIT (TYP) NOTES: INTERIOR WALLS TO BE FRAMED W/ 2x6@ 2'-0" O.C. EXTERIOR WALLS TO BE FRAMED W/ 2x6 @ 2'-0" O.C. U.N.O. ~4" CONCRETE SLAB ON GRADE~ ELEV. = 100'-0" 3 S1 TYP 2 S1 TYP 1 S1 TYP 2 S1 TYP 1 ALL WALLS TO BE SHEAR WALLS (SEE SHEET S1) U.N.O. 1 1 1 1 1 1 2 S1 TYP 12'-0" x 12'-0" OVERHEAD DOOR 12'-0" x 12'-0" OVERHEAD DOOR 12'-0" x 12'-0" OVERHEAD DOOR 12'-0" x 12'-0" OVERHEAD DOOR 12'-0" x 12'-0" OVERHEAD DOOR 12'-0" x 12'-0" OVERHEAD DOOR 12'-0" x 12'-0" OVERHEAD DOOR 12'-0" x 12'-0" OVERHEAD DOOR 12'-0" x 12'-0" OVERHEAD DOOR BACK WALL TO BE FRAMED W/ 2x6 WALL GIRTS @ 2'-0" O.C. 40 ' - 0 " (10) BAYS @14'-0" = 140' - 0" 1D 2D 3D 4D 5D 6D 7D 8D 9D 10D 11D 29 GA ROOF DECK ATTACH W/ #10 SCREWS @ 4 1/2" O.C. EDGES #10 SCREWS @ 9" O.C. FIELD SIDE LAP FASTENERS #10 SCREWS @ 15" O.C. (TYP) (SEE DETAIL B/S1) 5/8:12 SLOPE 4 S1 TYP 5 S1 6 S1 7 S1 T.O.W. =112'-0" T.O.W. =114'-0" @ 1 6 " O . C . 2x 1 0 R O O F P U R L I N S 5 S1 T.O.W. = VARIES T.O.W. = VARIES TH I S D R A W I N G I S T H E PR O P E R T Y O F T S E E N G I N E E R S , IT I S N O T T O B E R E P R O D U C E D OR T O B E U S E D F O R A N Y CO N S T R U C T I O N E X C E P T A S HE R E I N I N D I C A T E D W I T H O U T TH E E X P R E S S W R I T T E N CO N S E N T O F T S E E N G I N E E R S CH E C K E D B Y : EV B DR A W N B Y : DA T E RE V I S I O N S BY 13 6 S O U T H S T A T E S T R E E T SH E L L E Y , I D A H O 8 3 2 7 4 PH O N E ( 2 0 8 ) -35 7 -24 2 0 FA X ( 2 0 8 ) -35 7 -24 1 9 of f i c e @ t e t o n e n g . c o m PROJECT NO. SHEET NO. OF CO P Y R I G H T @ T S E E N G I N E E R S 2 0 2 3 o f f i c e @ t e t o n e n g . c o m DA T E : PRELIMINARY NOT FOR CONSTRUCTION T S E EN G I N E E R S BU S I N E S S P A R K L O T 8 JE N S E N G R E G O R Y C O M M E R C I A L S I L V E R T I P MA D I S O N C O U N T Y , I D A H O 223216 S2 09 / 2 6 / 2 3 TWO CS 1/8" = 1'-0" FOUNDATION PLAN 1/8" = 1'-0" ROOF FRAMING PLAN