Loading...
HomeMy WebLinkAboutAPPROVED UPDATED PLANS - 22-00502 - Mountain West Rental and SalesAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Todd Smith Todd.Smith@rexburg.org 208-372-2181 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Mountain West Rental and Sales Address : Record Type : New Commercial Building Document Filename : UPDATED PLANS - 22-00502 - Mountain West Rental and Sales.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 22-00502 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A1.0 Stamp Cody Jones : Building Open 1 Approved - Building Inspector A1.0 Free text Cody Jones : Building Open 1 Colt G stated Atlas will be doing special inspections. E3.0 Callout Alex Owens : Electrical Open 24 In talking with engineer, grounding is to meet 250.66 2017 NEC requirements E3.0 Line Alex Owens : Electrical Open 24 New Commercial Building As per Resolution 2022-07, adopted April 6, 2022, new development is required to follow standards for the installation of fiber conduit and distribution boxes. Location of conduit and distribution boxes need to be identified and shown on plans. Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C A1.0 Code Review & Plans, Notes Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-20-2022 Mo u n t a i n W e s t Prescriptive Code is being used for the Energy Code base on the following: Climate Zone: 6b Insulation Entirely Above Roof Deck: R-30ci Metal Building Ceiling: R-30+R-11 ls Mass: R13.3ci Metal Building Walls: R-13+R-14ci Metal Framed Walls: R-13+R-12.5ci Wood Stud Framed Walls: R-20+R-3.8ci Below Grade Walls: R-10ci Slab-on-Grade Floor: R-10 for 24" below Swinging Doors: U-Factor 0.37 Fixed Fenestration: U-Factor: 0.34 max, SHGC: SEW= .38 max, N=.38 max Operable Fenestration: U-Factor: .42 max, SHGC: SEW= .34 max, N=.34 max Entrance Doors: U-Factor 0.63 max Colt d stated Atlas will be doing special inspections. Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C A1.1 Building Plan Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-20-2022 Mo u n t a i n W e s t Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C A1.1 Reflected Ceiling Plans Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-20-2022 Mo u n t a i n W e s t Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C A2.0 Exterior Elevations Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-20-2022 Mo u n t a i n W e s t Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C A2.1 Sections Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-20-2022 Mo u n t a i n W e s t Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C A2.2 Sections Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-20-2022 Mo u n t a i n W e s t MEN restroom Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C A3.0 Interior Elevations, Door & Window Elevations, Sechedules Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-20-2022 Mo u n t a i n W e s t LOCKS, LATCHES, PULLS, EXIT DEVICE DOOR HARDWARE MOUNTING HEIGHT PUSH SIDE DETAIL SLIDING DOOR PULL SIDE * 12" MIN. REQUIRED IF DOOR HAS BOTH A CLOSER AND A LATCH. CLEAR DOORWAY WIDTH AND DEPTH FOLDING DOOR MAXIMUM DOORWAY DEPTH HINGED DOOR PUSH SIDE FRONT APPROACHES - SWINGING DOORS PULL SIDE NOTE: X = 36" MINIMUM IF Y = 60"; X = 42" MINIMUM IF Y = 54". PULL SIDE HINGE SIDE APPROACHES - SWINGING DOORS * 54" MINIMUM IF DOOR HAS CLOSER. PUSH SIDE *12" MIN. REQUIRED IF DOOR HAS BOTH A LATCH AND CLOSER. **48" MIN. REQUIRED IF DOOR HAS BOTH A LATCH AND CLOSER. *48" MINIMUM IF DOOR HAS CLOSER. LATCH SIDE APPROACHES - SWINGING DOORS 10" MAX S UNOBSTRUCTED HIGH SIDE REACH MAX SLOPE 1:48 PROVIDE CLEAR FLOOR SPACE S 404. DOORS AND DOORWAYS 308. REACH RANGES 404. DOORS AND DOORWAYS 306. KNEE CLEARANCE TABLEWARE AREAS 304. WHEELCHAIR TURNING SPACE 305. CLEAR FLOOR OR GROUND SPACE FOOD SERVICE LINES MINIMUM CLEARANCES FOR SEATING AND TABLES 10" MAX OBSTRUCTED HIGH SIDE REACH OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED FORWARD REACH CLEAR FLOOR SPACE IN ALCOVES CLEAR FLOOR SPACE FORWARD APPROACH PARALLEL APPROACH LC TOILET TISSUE DISPENSER LC Sinks Urinals LC LCGRAB BARS ACCESSIBILIT< STANDARDS Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C A3.1 ADA Details Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-20-2022 Mo u n t a i n W e s t PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 7/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) GENERAL REQUIREMENTS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. 7.SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN ADDITION TO ITEMS REQUIRED BY ARCHITECTURAL SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DRAWINGS SHALL BE FLAGGED UPON HIS REVIEW. VERIFY ALL DIMENSIONS WITH ARCHITECT. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER THE STRUCTURAL ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A STRUCTURAL ENGINEER REGISTERED IN THE APPROPRIATE STATE. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER ARE NOT TO BE CONSIDERED CHANGES TO ORIGINAL DRAWINGS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY THE OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ALLOW (5) WORKING DAYS FOR THE STRUCTURAL ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL WILL BE RETAINED FOR THE STRUCTURAL ENGINEER'S RECORDS. BASIS FOR DESIGN: 1.BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 4. SEISMIC DESIGN PARAMETERS: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SITE CLASS D SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.142, SS = 0.366 DESIGN SPECTRAL RESPONSE ACCELERATIONS SD1 = 0.219, SDS = 0.368 PERCENT STORAGE LOAD INCLUDED WITH SEISMIC LOADS 25 VERTICAL SHEAR TRANSFER ELEMENTS: PLYWOOD SHEARWALL(S)R = 6.5, CS = 0.057 5. WIND DESIGN PARAMETERS (STRENGTH): ULTIMATE WIND SPEED 115 MPH (3 SECOND GUST) WIND EXPOSURE C IMPORTANCE FACTOR Iw = 1.00 INTERNAL PRESSURE COEFFICIENT -0.18 COMPONENT AND CLADDING PRESSURE 40 PSF NET UPLIFT ON ROOF 20 PSF 2. VERTICAL LOADS: LOCATION LIVE / SNOW LOAD DEAD LOAD ROOF GROUND = 50 PSF ROOF = 35 PSF 15 PSF FLOOR (STORAGE)125 PSF 15 PSF 3. DEFLECTION LIMITS: ELEMENTS LIVE LOAD TOTAL LOAD ROOF TRUSSES/JOISTS L/360 L/240 FLOOR TRUSSES/JOISTS L/360 L/240 BEAMS L/360 L/240 FOUNDATION NOTES: 1.FOUNDATIONS DESIGNED IN CONFORMANCE WITH RECOMMENDATIONS BY: ENGINEERING TESTING CONSULTANTS, INC. REPORT NO. 3456 DATED JANUARY 1, 2007. 2.SITE PREPARATION AND GRADING REQUIREMENTS OF THE SOIL REPORT AND ANY ADDENDUM'S SHALL BE COMPLETED PRIOR TO CONSTRUCTION OF FOUNDATIONS. ANY TESTS OR INSPECTIONS REQUIRED BY THE SOIL REPORT SHALL BE PERFORMED PRIOR TO PLACEMENT OF FOUNDATION REINFORCING STEEL OR CONCRETE. ALTERATIONS TO SITE PREPARATION OR GRADING SHALL BE REPORTED TO THE GEOTECHNICAL ENGINEER PRIOR TO FOUNDATION CONSTRUCTION. (USE THE NEXT 4 PARAGRAPHS IF THERE IS NO SOIL REPORT) 1.IN LIEU OF A GEOTECHNICAL REPORT: THE FOUNDATION HAS BEEN DESIGNED ACCORDING TO THE RECOMMENDATIONS OF CHAPTER 18 OF THE IBC. 2.THE SOIL DESIGN VALUES LISTED BELOW HAVE BEEN APPROVED BY THE CITY/COUNTY BUILDING DEPARTMENT, CONTINGENT THAT THE SOIL ON THE SITE PREDOMINATELY CONSISTS OF SAND AND/OR GRAVEL. SPECIFIC SOIL CLASSIFICATIONS SHOULD BE ONE OF THE FOLLOWING: SANDY GRAVEL OR GRAVEL(GW OR GP), SAND(SW AND SP), SILTY SAND(SM), CLAYEY SAND(SC), SILTY GRAVEL(GM), OR CLAYEY GRAVEL(GC). THESE SOIL CLASSIFICATIONS CAN BE FOUND IN TABLE 1806.2 OF CHAPTER 18 OF THE IBC. VERIFICATION OF SOIL CLASSIFICATION IS THE RESPONSIBILITY OF THE CONTRACTOR. 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL OR COMPETENT NATIVE SOIL SUBBASE COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR). GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 1500 PSF ALLOWABLE LATERAL BEARING PRESSURE 150 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 FOUNDATION BEARING DEPTH 36" BELOW FINISHED GRADE CONCRETE: 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD-ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10.FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. LOCATION:MINIMUM COVER TOLERANCE CAST AGAINST EARTH (FOOTINGS)3"± 3 8" SLABS ON GRADE 112"± 14" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER 112"± 3 8" EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2"± 3 8" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1"18" STRUCTURAL SLABS AND WALLS 3 4"18" BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 112"3 8" 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT FOOTINGS 3500 PSI 0.50 5.5% ± 1% FOUNDATION WALLS 4500 PSI 0.45 5.5% ± 1% INTERIOR CONCRETE SLABS ON GRADE 3500 PSI 0.45 N/A REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, ELEVATED SLABS AND COLUMN REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. WOOD: 1.GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. DOUBLE UP JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" (NOMINAL) SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. UNLESS NOTED OTHERWISE ON PLANS/DETAILS PROVIDE 2x SOLID BLOCKING AT MID-HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO IBC TABLE 2304.10.1. JOIST HANGERS AND OTHER MISC. FRAMING ANCHORS SHALL BE SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT ICC-ES APPROVAL. 2.SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB). ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. SAWN LUMBER SHALL HAVE THE FOLLOWING MINIMUM GRADE UNLESS NOTED OTHERWISE IN SCHEDULES: USE:MATERIAL: 2x4 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) 2x6 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) JOISTS, TOP PLATES AND ALL OTHER SAWN LUMBER DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) BEAMS AND POSTS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) LOCATION:NOMINAL THICKNESS: SPAN INDEX RATING: EDGE ATTACHMENT: FIELD ATTACHMENT: WALL 716" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 716" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 15 32" OR 12"3216 8d AT 6" O.C.8d AT 12" O.C. ROOF 19 32" OR 5 8"40 20 10d AT 6" O.C.10d AT 12" O.C. ROOF 23 32" OR 3 4"48 24 10d AT 6" O.C.10d AT 12" O.C. ROOF 7 8"60 32 10d AT 6" O.C.10d AT 12" O.C. FLOOR 3 4" T&G 48 24 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 7 8" T&G 60 32 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 118" T&G 60 48 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. 3.PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: DEFERRED SUBMITTAL ITEMS: PREFABRICATED WOOD ROOF TRUSSES STEEL: 1.MATERIALS: ROLLED W SHAPES, SHALL CONFORM TO ASTM A992 (FY=50 KSI). ALL OTHER STRUCTURAL STEEL SHAPES, ROLLED SECTIONS, BARS AND PLATES SHALL CONFORM TO ASTM A36 (FY = 36 KSI). ALL PIPE STEEL SHALL BE ASTM A501 (FY = 36 KSI) OR ASTM A53, TYPE E OR S, GRADE B (FY = 35 KSI). ALL TUBULAR STEEL SHALL BE ASTM A500 (FY = 46 KSI). 2.ALL BOLTS AND STUDS SHALL BE ASTM A307, UNLESS NOTED OTHERWISE. ALL EXPANSION BOLTS TO HAVE CURRENT ICC REPORT RATING FOR MATERIAL INTO WHICH INSTALLATION TAKES PLACE. HEADED STUDS SHALL CONFORM TO ALL REQUIREMENTS OF THE LATEST EDITION OF THE "RECOMMENDED PRACTICES FOR STUD WELDING" AND THE "STRUCTURAL WELDING CODE" PUBLISHED BY AWS. ALL BOLTS, ANCHOR BOLTS, EXPANSION BOLTS, ETC. SHALL BE INSTALLED WITH STEEL WASHERS AT FACE OF WOOD OR AT SLOTTED HOLES IN STEEL SECTIONS. 3.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, LATEST EDITION. 4.WELDING SHALL BE BY WELDERS HOLDING VALID CERTIFICATES AND HAVING CURRENT EXPERIENCE IN THE TYPE OF WELD SHOWN ON THE DRAWINGS OR NOTES. ALL WELDING SHALL USE E70 SERIES LOW HYDROGEN RODS UNLESS NOTED OTHERWISE. ALL WELDING PER LATEST AMERICAN WELDING SOCIETY STANDARDS. ALL WELDS ON DRAWINGS ARE SHOWN AS SHOP WELDS. CONTRACTOR MAY SHOP WELD OR FIELD WELD AT HIS DISCRETION. ALL FULL PENETRATION WELDS SHALL BE TESTED AND CERTIFIED BY AN INDEPENDENT TESTING LABORATORY. 5.STEEL TO STEEL BOLTED CONNECTIONS: HIGH STRENGTH BOLTS SHALL BE ASTM A325N AND SHALL BE INSTALLED AS BEARING-TYPE CONNECTIONS WITH THREADS INCLUDED IN SHEAR PLANE (TYPE "N" CONNECTION UNLESS NOTED OTHERWISE). BOLTS MAY BE TIGHTENED USING ANY AISC APPROVED METHOD. 6.DRYPACK SHALL BE 5,000 PSI FIVE STAR NON-SHRINK GROUT OR EQUIVALENT. INSTALL DRYPACK UNDER BEARING PLATES BEFORE FRAMING MEMBER IS INSTALLED. AT COLUMNS, INSTALL DRYPACK UNDER BASE PLATES AFTER COLUMN HAS BEEN PLUMBED BUT PRIOR TO FLOOR OR ROOF INSTALLATION. SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 TYPICAL DETAILS T-SERIES S2.0 FOUNDATION PLAN --- S2.1 MEZZANINE FRAMING PLAN --- S3.0 FOUNDATION DETAILS 100 - SERIES S4.0 FRAMING DETAILS 200 - SERIES CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV GSN DN. DWG(S) EQ EQUIP EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA F.O.M. EXP. BOLT E.O.S. Ø OR DIA. C.I.P. C L C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT D L C.L.F. W/WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T L SLH SLV SIM SQ PSF PSI REINF PREFAB OPP P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH N/A LLV LLH HORIZ K(KIP) L L LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN MINIMUM MAX MAXIMUM POUNDS PER SQUARE FOOT GLUED-LAMINATED BEAMGLB PFT PREFAB FLOOR TRUSSES PRT PREFAB ROOF TRUSSES I.F.W.INSIDE FACE OF WALL PT PRESSURE TREATED CONCRETE COLUMNC.C. RME ROOF MOUNTED EQUIPMENT SCREWS AT FLOOR SHEATHING SHALL BE #8 SCREWS AND SHALL PENETRATE AT LEAST 112" INTO THE SUPPORTING MEMBER. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH AN APA AFG-01 QUALIFIED GLUE. PLYWOOD ALTERNATE: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ARCHITECT AND ROOFER. IT MAY NOT BE USED ON ROOFS WHERE BUILT-UP ROOF SYSTEM IS TO BE GUARANTEED BY ROOFER. RATED SHEATHING SHALL COMPLY WITH CURRENT ICC-ES REPORTS AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 132") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4.NOMINAL 2x AND 3x DECKING. TONGUE AND GROOVE TYPE. MINIMUM Fb = 1,600 PSI, MINIMUM E = 1,300,000 PSI. INSTALL WITH TONGUES UP SLOPE ON PITCHED ROOFS, AND OUTWARD IN THE DIRECTION OF LAYING ON FLAT ROOFS. NAIL EACH PLANK WITH 16d TOENAIL (THRU THE TONGUE) AND 16d FACE NAIL AT EACH SUPPORT. DECK SHALL BE INSTALLED AS SIMPLE SPAN WITH ALL PLANKS BEARING ON TWO SUPPORTS. FOR REFERENCE AND/OR ADDITIONAL INFORMATION SEE AITC 117-2010. 5.GLUED-LAMINATED BEAMS (GLB): GLUED-LAMINATED BEAMS SHALL BE DOUGLAS FIR COMBINATION AT 24F-V4 AT SIMPLE SPAN BEAMS AND 24F-V8 AT MULTI-SPAN AND CANTILEVERED BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: FB = 2,400 PSI, FV = 190 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,800 KSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. STANDARD CAMBER IS BASED ON A RADIUS OF CURVATURE OF 5000 FEET. 6.GLUED-LAMINATED COLUMNS: GLUED-LAMINATED COLUMNS SHALL BE DOUGLAS FIR COMBINATION 3 WITH THE FOLLOWING MINIMUM PROPERTIES: FBY = 2,100 PSI, FBX = 2000 PSI, FVY = 230 PSI, FVX = 265 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,900 KSI. ALL COLUMNS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. COLUMNS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. 7.LAMINATED VENEER LUMBER (LVL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LVLs SHALL BE: FB = 2,600 PSI, FV = 285 PSI, E = 2,000 KSI. 8.PARALLEL STRAND LUMBER (PSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR PSLs SHALL BE: FB = 2,900 PSI, FV = 290 PSI, E = 2,000 KSI. 9.LAMINATED STRAND LUMBER (LSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LSLs SHALL BE: FB = 2,325 PSI, FV = 310 PSI, E = 1,550 KSI. 10.SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF TREATED FIR. SHEAR WALLS AND EXTERIOR WALL SILLS AT CONCRETE SLAB SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS PER PIECE. PROVIDE ANCHOR BOLT AT 9" MAXIMUM, 4" MINIMUM FROM THE END OF EACH PIECE AT SPLICE OR END OF WALL. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72" ON CENTER UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FOR HOLDOWNS) SHALL EMBED 7" INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE SECURED TO CONCRETE WITH EITHER ANCHOR BOLTS OR POWER DRIVEN SHOT PINS UNLESS NOTED OTHERWISE ON PLANS. 11.BOLTING: ALL BOLTS IN WOOD CONNECTIONS SHALL CONFORM TO ASTM A307. BOLTS SHALL BE INSTALLED IN HOLES BORED WITH A BIT 116" LARGER THAN THE Ø (DIAMETER) OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NICK THREADS TO PREVENT LOOSENING. 12.PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. WHERE UNINHABITABLE ATTIC SPACE CAN BE USED FOR STORAGE, A 20 PSF LIVE LOAD ON THE BOTTOM CHORD SHALL BE INCLUDED IN THE ANALYSIS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE FOR BOTH ROOF AND FLOOR TRUSSES WHEN USED. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC-ES APPROVAL. ADDITIONAL TRUSSES SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PER IBC SECTION 2303.4 AND TPI-1: EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS, THE DESIGN LOADS, AND THE TRUSS SPACING - WITHIN TWO FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD. PREFABRICATED WOOD/STEEL WEB JOIST/PURLINS (TJI/TJL SERIES OR EQUAL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST EDITION ICC-ES REPORT. CONNECTIONS AND BEARING MATERIAL TO BE DESIGNED AND FURNISHED BY JOIST FABRICATOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED STRUCTURAL ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. ADDITIONAL JOISTS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C Ne w B u i l d i n g f o r : PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com S1.0 MO U N T A I N W E S T TB D RE X B U R G , I D A H O GENERAL STRUCTURAL NOTES . . . . 7/14/2022 RMSDBP22-235 KEYNOTES: 1.FINISHED GRADE WHERE OCCURS 2.DO NOT EXCAVATE A TRENCH CLOSER THAN A 45° ANGLE TO BELOW BOTTOM FOOTING OR FOUNDATION 3.BOTTOM OF CONCRETE FOOTING 4.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPE OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T1 TRENCH PARALLEL TO CONTINUOUS STRIP FOOTING TD01 NO SCALE 1 1 4 3 2 1 KEYNOTES: 1.CONCRETE FOOTING 2.SLEEVE - PROVIDE 12" MINIMUM CLEARANCE AROUND PIPE OR CONDUIT 3.PIPE OR CONDUIT 4.CONCRETE FILL TO BE PLACED BEFORE FOOTING IS POURED - FORM SAME AS FOOTING AND POUR FULL WIDTH OF PIPE TRENCH 5.STEM WALL NOTE: A.NO PIPE SHALL PASS THRU FOOTING OR UNDER COLUMN FOOTINGS. FOR TRENCHES GREATER THAN 3'-6" BELOW BOTTOM OF FOOTING, SEE PIPE PASSING BELOW WALL FOOTING DETAIL. T2 PIPE PASSING UNDER WALL FOOTING IN SHALLOW TRENCH TD02 NO SCALE 6" M I N 8" M I N 3' - 0 " M A X 8" MIN A SECTIONA 5 1 2 3 4 5 1 2 3 4 KEYNOTES: 1.STEM WALL 2.CONCRETE FOOTING 3.1'-6" MAXIMUM (WHERE TRENCH EXCEEDS 1'-6" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTINGS) 4.BACKFILL AND RECOMPACT TRENCH PER SOILS REPORT AND SPECIFICATIONS 5.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPES OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 3' - 1 " O R G R E A T E R FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T3 PIPE PASSING BELOW FOOTING IN DEEP TRENCH TD03 NO SCALE 5 3 2 1 44 1 KEYNOTES: 1.SLOPED FINISH GRADE 2.MINIMUM FOOTING DEPTH PER G.S.N. (12" MINIMUM) 3.DEEPEN FOOTING AS REQUIRED TO ACCOUNT FOR SLOPED GRADE 4.CONCRETE FOOTING NOTE: A.FOR ADDITIONAL INFORMATION, SEE PLANS AND DETAILS 5'-0" T4 TYPICAL DETAIL FOR FOUNDATION EMBEDMENT TD04 NO SCALE 1 2 3 4 KEYNOTES: 1.CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 3.LAP SPLICE PER TYPICAL STEEL REINFORCING LAP SPLICES IN CONCRETE DETAIL T5 TYPICAL CONCRETE CORNER TD05 NO SCALE 2 1 3 3 KEYNOTES: 1.CONCRETE SLAB ON GRADE 2.CONT KEYED JOINT 3.SAWCUT 18" WIDE x 14 SLAB THICKNESS IN DEPTH - CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE COMPLETE WITHIN 16 HOURS OF CONCRETE PLACEMENT. NOTE: A.KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS. B."TOOL WET JOINT", "ZIP STRIP", ETC SHALL MATCH SAWCUT REQUIREMENTS 12"6"6"12" SAWCUT JOINT KEYED JOINT T6 CONTROL JOINTS IN CONCRETE SLAB ON GRADE TD07 NO SCALE 1 3 1 2 T7 TYPICAL REINFORCING DETAILS TD10 NO SCALE 6 MIN BAR OFFSET BAR CLEARANCE SPLICE DETAIL BEND & HOOK DETAILS COLUMN TIES BEAM STIRRUPS "d" 45° "d" "d" 1 8 8 KEYNOTES: 1.LAP - SEE G.S.N. FOR MASONRY AND TYPICAL DETAIL FOR CONCRETE 2.MAXIMUM 15 LAP BUT NOT MORE THAN 6" 3.WIRE TIES 4.1d (1" MINIMUM) 5.RADIUS = 3d FOR BARS NOT OVER #8; 4d FOR #9, #10, AND #11 BARS; 5d FOR #14 AND #18 BARS, 5d FOR ALL GRADE 40 BARS WITH 180 DEGREE HOOK 6.4D (4" MINIMUM) 7.12d (90 DEGREE HOOK) 8.6d (4" MINIMUM) 9.135 DEGREE BEND 10.BEND AROUND 112" PIN FOR #3 BARS. BEND AROUND 2" PIN FOR #4 BARS. BEND AROUND 212" PIN FOR #5 BARS. 3 1 2 4 6 7 5 55 5 99 10 10 6 8 NOTES: 1.TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. 2.UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS AND WALLS SHALL BE CLASS "B" TENSION LAP SPLICES. BAR SIZE CLASS B TENSION SPLICE LENGTHS f'c = 3,000 PSI f'c = 4,000 PSI f'c = 5,000 PSI HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS #3 12"12"12"12"12"12" #4 19"15"17"13"15"12" #5 29"23"26"20"23"18" #6 32"25"28"21"25"19" #7 54"41"47"36"42"32" #8 70"54"61"47"54"42" #9 89"68"77"59"69"53" #10 112"87"97"75"87"67" T8 STEEL REINFORCING LAP SPLICES IN CONCRETE TD14 NO SCALE KEYNOTES: 1.CONCRETE FOOTING, SEE PLAN 2.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 3.#4 DOWEL TO MATCH FOOTING REINFORCEMENT 4.#4 DOWEL TO LAP AND MATCH WALL REINFORCEMENT NOTE: A.FOR ITEMS SHOWN BUT NOT KEYNOTED, SEE FOUNDATION DETAILS B.WHERE NEW FOOTING TIES INTO EXISTING FOOTING, DRILL AND EPOXY 24" LONG DOWELS INTO EXISTING, PROVIDE 4" MIN EMBEDMENT 2 3" CLR 3" CL R 24" 24" 1 3 2 1 4 24" 24" T9 CONCRETE FOOTING AT CONCRETE WALL TD12 NO SCALE T10 PLAN VIEW - HOLDOWN LOCATIONS/SHEARWALL END POSTS, "HD" TYPE HOLDOWNS USING SCREWS TD16 NO SCALE NOTE: A.ALL CONDITIONS MAY NOT BE SHOWN. FOR CONDITIONS NOT SHOWN, USE THESE DETAILS AS A GUIDE. B.SOME LARGER HOLDOWNS REQUIRE 6x6 POSTS, SEE PLANS AND SCHEDULES. C.WHERE MULTIPLE TRIMMER STUDS OR KING STUDS OCCUR, MAKE ADJUSTMENTS AS REQUIRED. KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.SHEARWALL SHEATHING, SEE PLAN 3.EDGE OF FOUNDATION 4.SIMPSON HD TYPE HOLDOWN WITH SCREWS 5.SHEARWALL END POST (2 STUDS) TYPICAL, EXCEPT AT HDU11, AND HDU14 WHERE 6x6 POST IS REQUIRED 6.25) - SIMPSON SDS 14"x6" LONG WOOD SCREWS, STAGGERED 7.SHEARWALL EDGE NAILING 8.TRIMMER STUD TO SUPPORT HEADER 9.BLOCK TO SUPPORT WINDOW SILL 10.BUILT UP WOOD POST (2) SHEARWALLS (1) "HD" HOLDOWN W/SCREWS "HD" HOLDOWN W/SCREWS WINDOW JAMB X "HD" HOLDOWN W/SCREWS DOOR JAMB OR WALL END X HOLDOWN X HD19 2-1/8" 1-5/16"HDU2, HDU4, HDU5 HTT4 HTT5 1-5/16" (2) SHEARWALLS (1) "HD" HOLDOWN W/SCREWS AT EXTERIOR CORNER X (1) SHEARWALL (1) "HD" HOLDOWN W/SCREWS AT EXTERIOR CORNER X AT RE-ENTRANT CORNER X (1) SHEARWALL (1) "HD" HOLDOWN W/SCREWS AT RE-ENTRANT CORNER X 4 WINDOW OPENING DOOR OPENING HDU14 1-9/16" LTT20B LTT19 1-3/8" 1-1/2" HDU8, HDU11 1-3/8" 3 2 7 4 1 3 2 7 7 2 1 981 3 4 4 8 3 1 4 7 2 3 6 3 2 77 32 410 5 5 5 5 5 5 5 3 3 1 2 7 2 7 3 6 1 T11 ELEVATION-TYPICAL 1-STORY SHEARWALL TD19 NO SCALE KEYNOTES: 1.SHEATHING MATERIAL 2.DOUBLE STUDS AT EACH END OF SHEARWALL, EDGE NAIL ALONG DOUBLE STUDS 3.FULL HEIGHT WOOD STUDS 4.BOTTOM PLATE ATTACHMENT 5.SIMPSON STHD TYPE HOLDOWN 6.MIDHEIGHT BLOCKING AND EDGE NAILING REQUIRED 7.SIMPSON "HD" TYPE HOLDOWN 8.FINISHED FLOOR 9.CONT 2x PT SOLE PLATE 1 3 6 8 7 4 5 2 9 KEYNOTES: 1.NAILS BETWEEN SPLICE LOCATION PER SCHEDULE - STAGGERED 2.DBL 2x TOP PLATE 3.WOOD STUD WALL, SEE PLAN 4.SPLICE OVER STUD 5.SIMPSON ST6224 OR MSTC40 STRAP AT LOCATIONS WHERE PLATES CAN NOT BE SPLICED NOTE: A.DO NOT SPLICE TOP PLATES WITHIN 6'-0" OF ENDS OF PLYWOOD SHEARWALLS. THIS DETAIL REQUIRED AT ALL EXTERIOR WALLS AND OVER SHEARWALLS - NOT REQUIRED AT INTERIOR NON-SHEARWALLS. (30) 16d (24) 16dLESS THAN 20' OVER 20' 4'-0" 6'-0" LENGTH OF WALL (BETWEEN CORNERS)SPLICE LENGTH NAILS ALONGSPLICE LENGTH MINIMUM SPLICE LENGTH PER SCHEDULE T12 ELEVATION - TYPICAL TOP PLATE SPLICE TD24 NO SCALE 4 5 1 3 2 3 2 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.WOOD HEADER 3.KING STUD(S) PER PLAN 4.(2) 16d NAILS AT 2" O.C. 5.16d NAILS AT 12" O.C. 6.TRIMMER STUD(S) PER PLAN 2 6 3 1 5 4 5 T13 TYPICAL HEADER CONNECTION TD25 NO SCALE 2 6 34 1 5 2 1 74 2 1 3 4 18 AT BEAM AT MID WALL AT TOP PLATE T14 TYPICAL BEAM POCKET TD26 NO SCALE KEYNOTES: 1.WOOD BEAM 2.(2) 16d NAILS AT 2" O.C. 3.KING STUD EACH SIDE OF BEAM 4.SOLID BUILT-UP POST BELOW BEAM 5.STRAP BROKEN TOP PLATE ON SIDE OR TOP 6.CONT DBL 2x TOP PLATE W/ LAP SPLICE PER TYPICAL DETAIL 7.FULL-HEIGHT KING STUD EACH SIDE OF BEAM 8.HGA10 CLIP EACH SIDE 9.FULL-HEIGHT KING STUD AT END OF BEAM 10.FULL-HEIGHT KING STUD, OPPOSITE SIDE OF THE BEAM 2 1 4 AT CORNER 10 9 2 NOTE: A.MINIMUM STAPLING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES 8d COMMON AT 12" O.C. 16 GA STAPLE AT 12" O.C. ALTERNATE FASTENER SCHEDULE ALTERNATE FASTENERSPECIFIED FASTENER 8d COMMON AT 6" O.C. 8d COMMON AT 4" O.C. 15 GA STAPLE AT 12" O.C. 14 GA STAPLE AT 12" O.C. 13 GA STAPLE AT 12" O.C. 16 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 3" O.C. 16 GA STAPLE AT 2.5" O.C. 15 GA STAPLE AT 2" O.C. 14 GA STAPLE AT 3" O.C. 13 GA STAPLE AT 4" O.C. 8d COMMON AT 3" O.C. MATERIAL: 7/16" SHEARWALL OR ROOF SHEATHING NOTES: 1.STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7 16" INCH OUTSIDE DIMENSION. AND INSTALLED WITH CROWN PARALLEL TO THE LONG DIMENSION OF FRAMING MEMBER. 2.FRAMING SHALL BE 3x OR WIDER WHEN NAIL SPACING IS LESS THAN 3 INCHES ON CENTER. 3.ALL STAPLES SHALL HAVE 112" LONG LEGS MINIMUM. 4.STAPLE SIZES AND SPACING PER REPORT NO. ICC-ESR-1539 T16 ALTERNATE SHEATHING STAPLE OPTION TD32 NO SCALE CONNECTION TYPE JOIST OR TRUSS BEARING ON SILL OR GIRDER BRIDGING TO JOIST SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL TOP PLATE TO STUD DOUBLE STUDS, FACE NAIL DOUBLE TOP PLATES CONTINUOUS HEADER TO STUD CEILING JOISTS, LAPS OVER PARTITIONS CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL RAFTER OR TRUSS TO PLATE BUILT-UP CORNER STUDS TOENAIL (4)-8d COMMON (2 1/2" x 0.131") NAILING (3)-8d COMMON (2 1/2" x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL EACH END(2)-3"x 0.131" NAILS (Gun Nail) (2)-3"x 14 GAUGE STAPLES 16d (3 1/2"x 0.135") AT 16" O.C. FACE NAIL 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES SOLE PLATE TO STUD END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES FACE NAIL 16d (3 1/2"x 0.135") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 8" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. FACE NAIL 16d (3 1/2"x 0.135") AT 16" O.C. 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 12" O.C. DOUBLE TOP PLATES - FACE NAIL (8)-16d COMMON (3 1/2"x 0.162") (12)-3"x 0.131" NAILS (Gun Nail) (12)-3"x 14 GAUGE STAPLES LAP SPLICE RIM JOIST TO TOP PLATE 8d (2 1/2"x 0.131") AT 6" O.C. 3"x 14 GAUGE STAPLES AT 6" O.C. 3"x 0.131" NAILS (Gun Nail) AT 6" O.C. BLOCKING BETWEEN JOISTS OR RAFTERS TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES AND TOP PLATE TOENAIL TOP PLATES, LAPS AND INTERSECTIONS FACE NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES CONTINUOUS HEADER, TWO PIECES 16d COMMON (3 1/2"x 0.162") FACE NAIL AT 16" O.C. ALONG EDGES CEILING JOISTS TO PLATE TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (5)-3"x 0.131" NAILS (Gun Nail) (5)-3"x 14 GAUGE STAPLES FACE NAIL (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES FACE NAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL TOENAIL 16d COM.(3 1/2"x 0.162") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 16" O.C. 3"x 0.131" NAILS (Gun Nail) AT 16" O.C.FACE NAIL (2)-8d COMMON (2 1/2" x 0.131") USE- SIMPSON A35 AT 48" O.C.-NA- SIMPSON A35 AT EVERY OTHER BLOCK -NA- NOTE: A.MINIMUM NAILING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES B.NAILING NOT NOTED ON THESE PLANS OR DETAILS SHALL BE PER I.B.C. TABLE 2304.10.1 T15 MINIMUM NAILING SCHEDULE - UNLESS NOTED OTHERWISE TD34 NO SCALE PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 7/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C Ne w B u i l d i n g f o r : PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com S1.1 MO U N T A I N W E S T TB D RE X B U R G , I D A H O TYPICAL DETAILS . . . . 7/14/2022 RMSDBP22-235 6" CONCRETE SLAB ON GRADE W/ #4 AT 24" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 100'-0" CONCRETE SLAB ON GRADE (SHOP SPACE) 1 A 2 3 4 5 6 7 8 9 10 B C D A B C D 1 2 3 4 5 6 7 8 9 10 27'-0"27'-0"25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"26'-0" 230'-0" 8'-6"10'-0"3'-0"3'-4"1'-0" 1'-2" 1'-4"23'-8"6'-6"12'-0"1'-2"3'-4"2'-0"12'-0"6'-6"6'-6"7'-0"12'-0"6'-0" 4' - 0 " 20 ' - 0 " 4' - 0 " 1'-4" 1'-2" 79 ' - 4 " HO L D T H I S D I M E N S I O N 4" 4" 27'-0"27'-0"25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"26'-0" 24'-8"6'-0"12'-0"7'-0"12'-0"6'-6"6'-6"6'-6"12'-0"2'-0"3'-4" 1'-2" 23'-8"1'-4" 1'-2" 7'-4"10'-0"8'-6" 1'-2" 25'-10" 54'-0"176'-0" 78 ' - 1 1 2" HO L D T H I S D I M E N S I O N 11 1 4" 11 1 4" 26 ' - 0 " 28 ' - 0 " 26 ' - 0 " 2' - 0 " 24 ' - 0 " 2' - 0 " 80 ' - 0 " 26 ' - 0 " 28 ' - 0 " 26 ' - 0 " WF16 / W1 WF 1 6 / W 1 WF 1 4 1 4 101 WF16 / W1 WF 1 6 / W 1 102 102 102 F36 F60 F90 4 WF 1 4 4 4 F90 F60 F90 F60F90 2 60° TYP 2 F72 2 F72 2 F72 2 F72 2 F72 2 F7260° TYP 2 60° TYP 2F72 2F72 2F72 2F72 2F72 2F72 60° TYP 4" CONCRETE SLAB ON GRADE W/ #3 AT 24" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 100'-0" CONCRETE SLAB ON GRADE (OFFICE SPACE) WF 1 8 WF18 WF18 F36 F72 F72 6 0 ° T Y P 3 F36 F36 3 WF 1 8 A A A A F48F48 F48 F48 F48 F48 WF18 WF18 WF18 F36 F36 F24 F24 F242'-6"10'-0"10'-0"2'-6" 3' - 3 " 110 WF18 115 114 103 5 5 5 5 7 110 109 102 102 102 102 113 101 TYP 116 OPP 108 F60 TYP 116 TYP 116 101 1 1 1 1 1 111 11 107106 106 SIM 112 SIM 112106 108 TYP 116 101 113 102 102 102 102 WF18 109 110 7 103 110110 110 110 110 110 TYP 101 OPP 111 101 112 102 1 112 101 104 105 105 104 110 110 110 110 110 111TYP 101 SC1SC1 SC1SC1 SC1SC1SC1SC1 SC1SC1 SC1SC1 SC1SC1 SC1SC1 SC1SC1 SC1SC1 SC1SC1 SC1SC1 SC1SC1 SC1 SC1 102 1 F24 F24 SC1SC1 2' - 0 " TY P F24 WF 1 8 WF 1 8 WF 1 8 WF 1 8 WF 1 8 WF 1 8 WF 1 8 WF18 WF18 WF18 F24F24 F24 F24 F24F24 F24 WF 1 8 2'-0" TYP WF18 F24 F24 5 5 5 WF 1 4 WF 1 8 WF 1 8 T.O.W. 101'-0" T.O.F. 97'-6" T.O.W. 101'-0" T.O.F. 97'-6" T.O.W. 101'-0" T.O.F. 97'-6" 5 6. 6. A A AA SCALE: FOUNDATION PLAN 1/8" = 1'-0" PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 7/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C Ne w B u i l d i n g f o r : PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com S2.0 MO U N T A I N W E S T TB D RE X B U R G , I D A H O FOUNDATION PLAN . . . . 7/14/2022 RMSDBP22-235 SHEARWALL HOLDOWN SCHEDULE NOTES: 1. SEE TYPICAL DETAILS FOR ANCHOR BOLT EMBEDMENT REQUIREMENTS. 2. POSTS SHOWN ON THE PLANS ARE A MINIMUM AS REQUIRED TO SUPPORT THE GRAVITY LOADS OF THE STRUCTURE. ADDITIONAL STUDS OR SOLID POSTS MAY BE REQUIRED DEPENDENT ON HOLDOWN TYPES. MARK HOLDOWN SHEARWALL END POST UNO ON PLAN ALTERNATE HOLDOWN ANCHOR BOLT DIA. SIMPSON HTT4 W/ (18) 0.162x2.5" NAILS (2) 2x STUDS N/A SSTB24A A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. E. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. F. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. G. , , - AS SHOWN ON PLAN INDICATES A SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION. H.W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. I.WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. J.F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. K.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. L.SC1, SC2, ETC. - AS SHOWN ON PLAN INDICATES A STEEL COLUMN. SEE STEEL COLUMN SCHEDULE FOR ADDITIONAL INFORMATION. COLUMNS START AT THE LEVEL THEY ARE CALLED OUT ON. M.VERIFY EXACT SIZE AND LOCATION OF DEPRESSED AND/OR RAISED SLABS WITH ARCHITECTURAL DRAWINGS. N.FOR SIDEWALK AND LANDING LOCATIONS, SEE ARCHITECTURAL DRAWINGS. FOUNDATION PLAN NOTES 5 6.7 A B FOOTING SCHEDULE NOTES: 1. FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. 2. FOR MINIMUM CLEARANCE (CLR) OF REINFORCING, SEE GENERAL STRUCTURAL NOTES (GSN). MARK LENGTH WIDTH THICKN ESS FOOTING REINFORCING REMARKS F24 24"24"10"(3) #4 EACH WAY BOTTOM --- F36 36"36"10"(4) #4 EACH WAY TOP AND BOTTOM --- F48 48"48"10"(4) #4 EACH WAY BOTTOM --- F60 60"60"10"(5) #4 EACH WAY TOP AND BOTTOM --- F72 72"72"12"(6) #5 EACH WAY TOP AND BOTTOM --- F90 90"90"12"(7) #5 EACH WAY TOP AND BOTTOM --- WF14 CONT 14"12"(2) #8 CONT TOP AND BOTTOM WF16 CONT 16"10"(2) #4 CONT BOTTOM WF18 CONT 18"10"(2) #4 CONT BOTTOM --- MONO POUR W/ SLAB STRIP FOOTING WALL (W) SCHEDULE MARK THICKNESS AND TYPE VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 8" CONCRETE #4 AT 18" O.C.#4 AT 12" O.C.--- SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 716" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 716" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 32" O.C. WOOD:16d STAGGERED AT 4" O.C. 716" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 3" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 18" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 26" O.C. WOOD:16d STAGGERED AT 3" O.C. 5 6. 7 1.VERIFY DOOR OPENING W/ ARCHITECT AND METAL BUILDING MANUFACTURER DRAWINGS. 2.(1) #6x20'-0" LONG (10'-0" EACH LEG) HAIRPIN. 3.(1) #4x15'-0" LONG (7'-6" EACH LEG) HAIRPIN. 4.(2) #8x10'-0" LONG (5'-0" EACH LEG) HAIRPIN. WIDEN GRADE BEAM AT CONCRETE PIER AS NECESSARY TO MAINTAIN 3" CLR AROUND ALL REINFORCING. 5.THICKEN FOOTING AS REQUIRED FOR HOLDOWN ANCHOR EMBEDMENT. PLAN KEYNOTESXSTEEL COLUMN (SC) SCHEDULE MARK SIZE BASE CONNECTION SC1 HSS4x4x5 16 SEE DETAILS WJ3 WJ3 WJ2 WJ 1 B1 B1 B4 B4 B4 B4 B2 B4 B4 B1 W12x53 W12x53 W12x53 B1 B1 1 A 2 3 4 5 6 7 8 9 10 B C D A B C D 1 2 3 4 5 6 7 8 9 10 2 OPEN P1 P3 P1 P1 P2 P1 P2 P2 P1 5 5 5 5 7 7 GT PREFAB WOOD TRUSS AT 24" O.C. 11 11 2 2 2 2 2 B3 B3 WJ3 WJ3 WJ3 WJ3 B4 B4 201 202 206 209 208 203 206 209 208 202207 203 206 208 202 205 209 203 202 204 202 210 211 OPP 201 B5 B5 B5 213 B5 B5 B5 26 GAGE PBR ROOF PANEL W/ (4) #10 SCREWS AT EACH SUPPORTING MEMBER. INSTALL PER MANUFACTURERS RECOMMENDATIONS B5 B5 B5 B5 B5 26 GAGE PBR ROOF PANEL W/ (4) #10 SCREWS AT EACH SUPPORTING MEMBER. INSTALL PER MANUFACTURERS RECOMMENDATIONS B5 B5 212 26 GAGE PBR ROOF PANEL W/ (4) #10 SCREWS AT EACH SUPPORTING MEMBER. INSTALL PER MANUFACTURERS RECOMMENDATIONS B5 B5 B5 212 B5 B5 B5 B5 212 B5 B5 B5 B5 212 B5 B5 B5 B5 212 B5 26 GAGE PBR ROOF PANEL W/ (4) #10 SCREWS AT EACH SUPPORTING MEMBER. INSTALL PER MANUFACTURERS RECOMMENDATIONS B5 B5 B5 B5 26 GAGE PBR ROOF PANEL W/ (4) #10 SCREWS AT EACH SUPPORTING MEMBER. INSTALL PER MANUFACTURERS RECOMMENDATIONS 212 TYPICAL FLOOR SHEATHING: 3/4" APA RATED FLOOR SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. P2 P2 B4 2 P2 4 214 19/32" APA RATED ROOF SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: 3 6. 6. SCALE: MEZZANINE FRAMING PLAN 1/8" = 1'-0" PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 7/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C Ne w B u i l d i n g f o r : PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com S2.1 MO U N T A I N W E S T TB D RE X B U R G , I D A H O MEZZANINE FRAMING PLAN . . . . 7/14/2022 RMSDBP22-235 SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 716" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 716" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 32" O.C. WOOD:16d STAGGERED AT 4" O.C. 716" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 3" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 18" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 26" O.C. WOOD:16d STAGGERED AT 3" O.C. 5 6. 7 FLOOR FRAMING PLAN NOTES A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D.TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. UNO. E.PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS NOTED ON PLANS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. G. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. H. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. I.B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. J.WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A WOOD JOIST. SEE WOOD JOIST SCHEDULE FOR ADDITIONAL INFORMATION. K.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. L.FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. M.ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. 5 6.7 POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P2 (5) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P3 (3) 2x4 DOUG FIR NO. 2 SEE TYPICAL DETAILS 1.ATTACH JOIST WITH INVERTED LUS26-2 HANGERS. 2.STRAP BEAMS TOGETHER / TO DOUBLE TOP PLATE W/ MSTC40. 3.NO HEADER WILL BE PROVIDED BELOW. TRUSS SHALL BE DESIGNED TO SPAN OVER THE OPENING. LIMIT DEFLECTION TO L/600 FOR TOTAL LOAD. TRUSS SHALL BE DESIGNED FOR DEAD LOAD OF 150 PLF AND SNOW LOAD OF 225 PLF. 4.ATTACH BEAM TO BEAM WITH HUC412 HANGER. PLAN KEYNOTESX BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 13 4x512 LVL B2 (2) 2x10 OR 4x10 OR (2) 13 4x714 LVL B3 (2) 13 4x512 LVL B4 (2) 13 4x117 8 LVL B5 HSS10x4x316 WOOD JOIST ( ) SCHEDULE MARK JOIST FACE MOUNT HANGER TOP FLANGE HANGER WJ1 2x10 AT 16" O.C.LUS210 LB210 WJ2 117 8" TJI 210 AT 16" O.C.IUS2.06/11.88 ITS2.06/11.88 WJ3 117 8" TJI 210 AT 12" O.C.IUS2.06/11.88 ITS2.06/11.88 WJ KEYNOTES: 1.PRE-ENGINEERED BUILDING BEYOND 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 8.#4 BENT DOWEL AT 18" O.C. 102 PRE-ENGINEERED BUILDING AT CONCRETE FOOTING CS_MB102 NO SCALE 3" CLR 3" CL R 1 5 6 7 8 3 2 3 4 18" 18" KEYNOTES: 1.PRE-ENGINEERED BUILDING 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 101 PRE-ENGINEERED BUILDING AT CONCRETE FOOTING NO SCALE 3" CLR 3" CL R 1 5 6 7 3 2 4 KEYNOTES: 1.PRE-ENGINEERED BUILDING BY OTHERS 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 8.CONT 2x PT SOLE PLATE W/ SIMPSON STRONG BOLT 2 (ESR-3037) HILTI ANCHORS KWIK-BOLT TZ (ESR-1917) OR SIMILAR APPROVED PRODUCT, SEE SHEARWALL SCHEDULE FOR SIZE AND SPACING 9.WALL SHEATHING AS OCCURS, SEE PLAN 10.WOOD STUD WALL, SEE PLAN 1 33 2 7 5 10 9 8 4" MI N 3" CLR 3" CL R 6 5 4 3'-4" A.F.F. KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ 5 8"Ø EXPANSION ANCHORS AT SPACING PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7.WALL SHEATHING AS OCCURS, SEE PLAN 3" CLR 3" CL R 7 6 5 1 2 4 3 104 WOOD STUD WALL AT FOUNDATION NO SCALE 312" MI N 106 WOOD STUD WALL AT FOUNDATION CW_S101 NO SCALE 3" CLR 3" CL R 8 10 7 9 6 8 1 2 5 4 3 8" MI N KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 9.EDGE NAILING, SEE SHEARWALL SCHEDULE 10.WALL SHEATHING AS OCCURS, SEE PLAN NOTES: A.WATERPROOF ANY EXTERIOR WOOD FRAMING WITHIN 8" OF GRADE PER ARCH DRAWINGS KEYNOTES: 1.CONCRETE SLAB ON GRADE, SEE PLAN 2.CONCRETE GRADE BEAM, SEE PLAN 107 CONCRETE GRADE BEAM AT CONCRETE SLAB CS_MB104 NO SCALE 2 1 3" CLR 3" CL R PER PLAN PE R PL A N KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.14"x19" CONCRETE PIER W/ (14) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.ANCHOR BOLTS W/ NUT AT BOTTOM 9.CONCRETE SLAB ON GRADE, SEE PLAN 108 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 9 7 4 1 8 6 2 3" CLR 3" CL R A PLANA 1'-1" 1' - 1 " KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.18"x23" CONCRETE PIER W/ (18) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.ANCHOR BOLTS W/ NUT AT BOTTOM 9.HAIRPIN AS OCCURS, SEE PLAN 10.CONCRETE SLAB ON GRADE, SEE PLAN 11.CONCRETE GRADE BEAM, SEE PLAN 109 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 7 4 1 8 6 2 3" CLR 3" CL R A PLANA 1'-11" 1' - 6 " KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.14"x17" CONCRETE PIER W/ (8) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.ANCHOR BOLTS W/ NUT AT BOTTOM 9.HAIRPIN AS OCCURS, SEE PLAN 10.CONCRETE SLAB ON GRADE, SEE PLAN 110 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 10 9 7 4 1 8 6 2 3" CLR 3" CL R A PLANA 1'-5" 1' - 2 " KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.14"x16" CONCRETE PIER W/ (8) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.ANCHOR BOLTS W/ NUT AT BOTTOM 9.CONCRETE SLAB ON GRADE, SEE PLAN 111 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 9 7 4 1 8 6 2 3" CLR 3" CL R A PLANA 1'-4" 1' - 2 " 114 STEEL COLUMN AT FOUNDATION NO SCALE KEYNOTES: 1.STEEL COLUMN, SEE PLAN 2.12"x6"x6" STEEL EMBED PLATE W/ (2) 5 8"x18" LONG DBAs 3.(3) #3 TIES IN TOP 5" OF PIER AND AT 8" O.C. REMAINDER 4.4'-0" MINIMUM FOOTING DEPTH, SEE GSN 5.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.14"Ø CONCRETE PIER W/ (8) #5 BARS VERTICAL 8.CONCRETE FOOTING, SEE PLAN 3 1 2 7 6 3" CL R 4 KEYNOTES: 1.PRE-ENGINEERED BUILDING BY OTHERS 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 8.STEEL COLUMN, SEE PLAN 9.12" THICK PLATE W/ (4) 12"Ø HEADED ANCHOR BOLTS W/ 8" MIN EMBEDMENT 1 33 2 7 5 8 3" CLR 3" CL R 6 5 4 103 PRE-ENGINEERED BUILDING AT CONCRETE FOUNDATION NO SCALE 4" 1' - 4 " 10 9 48" MIN LAP 11 9 KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.14"x7" CONCRETE PIER W/ (6) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.ANCHOR BOLTS W/ NUT AT BOTTOM 9.HAIRPIN AS OCCURS, SEE PLAN 10.CONCRETE SLAB ON GRADE, SEE PLAN 112 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 10 9 7 4 1 8 6 2 3" CLR 3" CL R A PLANA 7" 1' - 2 " KEYNOTES: 1.PRE-ENGINEERED COLUMN, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE STEM WALL BEYOND, CONT REINFORCEMENT TROUGH PIER (NOT SHOWN FOR CLARITY) 4.MINIMUM FOOTING DEPTH, SEE GSN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 6.CONCRETE FOOTING, SEE PLAN 7.18"x23" CONCRETE PIER W/ (14) #5 HOOKED DOWELS AND (3) #3 TIES IN TOP 5" AND AT 8" O.C. REMAINDER 8.ANCHOR BOLTS W/ NUT AT BOTTOM 9.HAIRPIN AS OCCURS, SEE PLAN 10.CONCRETE SLAB ON GRADE, SEE PLAN 11.CONCRETE GRADE BEAM, SEE PLAN 113 PRE-ENGINEERED COLUMN AT CONCRETE FOOTING NO SCALE 5 3 7 4 1 8 6 2 3" CLR 3" CL R A PLANA 1'-7" 1' - 6 " 4" 1' - 4 " 10 9 48" MIN LAP 11 9 1'-11" 5555 115 PRE-ENGINEERED BUILDING AT CONCRETE FOUNDATION NO SCALE PLANA 112" TY P 112" TY P 11 2" 9 8 3/16 11 2"3"11 2" 11 2"3" A 9 KEYNOTES: 1.PRE-ENGINEERED BUILDING BY OTHERS 2.CONCRETE STEM WALL, SEE PLAN 3.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 4.MINIMUM FOOTING DEPTH, SEE GSN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.CONCRETE SLAB ON GRADE, SEE PLAN 8.STEEL COLUMN, SEE PLAN 9.12" THICK PLATE W/ (4) 12"Ø HEADED ANCHOR BOLTS W/ 8" MIN EMBEDMENT 10.12"x6"x6" STEEL EMBED PLATE W/ (2) 5 8"Øx18" LONG DBAs 11.7" SQUARE CONCRETE WALL POP-OUT W/ (4) #4 HOOKED DOWELS 1 3 2 7 5 8 3" CLR 3" CL R 6 5 4 116 PRE-ENGINEERED BUILDING AT CONCRETE FOUNDATION NO SCALE PLANA 112" TY P 112" TY P 11 2" 9 8 3/16 11 2"3"11 2" 11 2"3" A 9 8 10 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ O.145"Ø MIN SHOT PIN AT 32" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 3" CLR 3" CL R 5 1 2 4 3 105 WOOD STUD WALL AT FOUNDATION CW_S108 NO SCALE NOTES: A.AT SIM, HAIRPIN IS NOT REQUIRED 3/16 11 3/16 8 PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 7/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C Ne w B u i l d i n g f o r : PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com S3.0 MO U N T A I N W E S T TB D RE X B U R G , I D A H O FOUNDATION DETAILS . . . . 7/14/2022 RMSDBP22-235 KEYNOTES: 1.WOOD JOIST W/ (2) 16d NAILS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.CONT RIM BOARD 7.BOUNDARY NAILING, SEE PLAN 8.A35 CLIP BETWEEN EVERYOTHER JOIST 9.FLOOR SHEATHING, SEE PLAN 10.PRE-ENGINEERED BUILDING 1 2 3 5 4 7 6 9 10 8 201 WOOD JOIST AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.WOOD JOIST BLOCKING AT 24" O.C. W/ (2) 16d NAILS 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.WOOD STUD WALL, SEE PLAN 5.WALL SHEATHING AS OCCURS, SEE PLAN 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7.CONT RIM BOARD W/ A35 CLIP AT 32" O.C. 8.BOUNDARY NAILING, SEE PLAN 9.FLOOR SHEATHING, SEE PLAN 10.(4) 10d NAILS INTO EACH BLOCK 202 WOOD JOIST AT WOOD STUD WALL NO SCALE 1 3 4 6 5 8 7 9 2 10 KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.FLOOR SHEATHING, SEE PLAN 3.BOUNDARY NAILING, SEE PLAN 4.WOOD BEAM, SEE PLAN 1 3 4 2 203 WOOD JOIST AT WOOD BEAM NO SCALE KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.BOUNDARY NAILING, SEE PLAN 5.CONT 2x BOTTOM PLATE, ATTACH PER SHEARWALL SCHEDULE 6.WOOD JOIST BLOCKING W/ (4) 16d NAILS BETWEEN EACH JOIST 7.FLOOR SHEATHING, SEE PLAN 204 WOOD JOIST AT WOOD STUD WALL NO SCALE 1 3 2 6 7 4 3 5 205 WOOD JOIST AT WOOD BEAM NO SCALE KEYNOTES: 1.FLOOR SHEATHING, SEE PLAN 2.BOUNDARY NAILING, SEE PLAN 3.WOOD JOIST W/ HANGER, SEE PLAN 4.WOOD BEAM, SEE PLAN 3 4 21 3 206 WOOD JOIST AT STEEL BEAM NO SCALE KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.STEEL BEAM, SEE PLAN 3.CONT 2x W/ 5 8"Ø THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 4.FLOOR SHEATHING, SEE PLAN 5.(4) 10d NAILS AT EACH JOIST 6.JOIST BLOCKING W/ (4) 16d NAILS BETWEEN EACH JOIST 7.BOUNDARY NAILING, SEE PLAN 1 4 2 3 5 7 6 KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.WOOD JOIST BLOCKING W/ (4) 16d NAILS BETWEEN EACH JOIST 7.FLOOR SHEATHING, SEE PLAN 8.BOUNDARY NAILING, SEE PLAN 207 WOOD JOIST AT WOOD STUD WALL NO SCALE 1 3 2 5 6 4 78 KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2.2x4 x 8'-0" LONG AT 6'-0" O.C. W/ (2) 16d NAILS AT EACH TRUSS 3.WOOD TRUSS W/ HGA10 CLIP AT 36" O.C. 4.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 5.WOOD STUD WALL, SEE PLAN 6.WALL SHEATHING AS OCCURS, SEE PLAN 7.EDGE NAILING, SEE SHEARWALL SCHEDULE 8.2x BLOCKING W/ LTP4 BETWEEN EACH JOIST 9.WOOD JOIST, W/ H3 CLIP AND HANGER SEE PLAN 10.BOUNDARY NAILING, SEE PLAN 11.ROOF SHEATHING, SEE PLAN 12.WOOD GIRDER TRUSS W/ (2) H3 CLIPS AT BEARING WALLS, SEE PLAN 10 1 2 3 4 5 6 8 9 11 10 12 7 7 210 WOOD TRUSS AT WOOD STUD WALL NO SCALE NOTES: A.COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS KEYNOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.ROOF SHEATHING, SEE PLAN 7.FULL-HEIGHT 2x BLOCKING BETWEEN EACH TRUSS W/ A35 CLIP 8.BOUNDARY NAILING, SEE PLAN 1 2 3 5 4 6 8 7 211 WOOD TRUSS AT WOOD STUD WALL NO SCALE NOTES: A.2x BLOCKING MAY BE OMITTED EVERY THIRD BAY B.COORDINATE ROOF VENTILATION C.FASCIA PER ARCHITECTURAL DETAILS KEYNOTES: 1.WOOD JOIST, SEE PLAN 2.STEEL BEAM W/ WEB STIFFENER ON EACH SIDE, SEE PLAN 3.CONT 2x W/ 5 8"Ø THREADED STUDS W/ WASHER AT 32" O.C. (COUNTER SINK AS REQUIRED) 4.FLOOR SHEATHING, SEE PLAN 5.BOUNDARY NAILING, SEE PLAN 6.WOOD BEAM, SEE PLAN 7.(2) 12"Ø LAG SCREW W/ 5" MIN EMBEDMENT INTO POST 8.BUILT-UP POST, SEE PLAN 1 2 3 5 4 6 8 208 STEEL BEAM AT WOOD POST NO SCALE 7 KEYNOTES: 1.STEEL BEAM, SEE PLAN 2.(2) 16d NAILS INTO EACH KING STUD 3.KING STUD EACH SIDE OF BEAM 4.SOLID BUILT-UP POST BELOW BEAM 5.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 6.WEB STIFFENER ON EACH SIDE OF BEAM 1 2 3 5 4 209 STEEL BEAM AT WOOD STUD WALL NO SCALE 2 3 KEYNOTES: 1.PRE-ENGINEERED BUILDING 2.STEEL BEAM, SEE PLAN 3.STEEL COLUMN, SEE PLAN 4.WOOD STUD WALL, SEE PLAN 5.ROOF PANEL, SEE PLAN 212 STEEL AWNING AT STEEL BUILDING NO SCALE 1/4 EACH SIDE 1'-0" MAX 1/4 EACH SIDE 1/4 EACH SIDE 1/4 EACH SIDE 1 3 2 5 4 3 2 2 KEYNOTES: 1.PRE-ENGINEERED BUILDING 2.STEEL BEAM, SEE PLAN 3.STEEL COLUMN, SEE PLAN 4.WOOD STUD WALL, SEE PLAN 5.ROOF PANEL, SEE PLAN 213 STEEL AWNING AT STEEL BUILDING NO SCALE 1/4 EACH SIDE 1'-0" MAX 1/4 EACH SIDE 1/4 EACH SIDE 1/4 EACH SIDE 1 3 2 5 4 3 2 2 1/4 EACH SIDE 6 6 KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2.WOOD GIRDER TRUSS, SEE PLAN 3.ROOF SHEATHING, SEE PLAN 4.BOUNDARY NAILING, SEE PLAN 5.WOOD WALL W/ 2x4 STUDS AT 16" O.C. BETWEEN METAL BUILDING Z-GIRTS 6.METAL BUILDING SHEATHING 7.2x BLOCKING 8.(3) #10 SCREWS INTO EACH BLOCK 9.WALL SHEATHING, SEE SHEARWALL ACHEDULE 10.EDGE NAILING, SEE SHEARWALL SCHEDULE 11.A34 CLIP AT EACH STUD 12.CONTINUOUS 2x6 LEDGER 13.Z-GIRT AS OCCURS 10 1 2 3 4 5 6 8 9 11 10 12 7 214 WOOD TRUSS AT METAL BUILDING NO SCALE 13 13 PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 7/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C Ne w B u i l d i n g f o r : PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com S4.0 MO U N T A I N W E S T TB D RE X B U R G , I D A H O FRAMING DETAILS . . . . 7/14/2022 RMSDBP22-235 EF 1 EF 2 CH 1 CH 2 CU 1 CU 2 CU 3 CD-2 50 CD-2 150 CD-1 200 12 " Ø D U C T S O X 14 " Ø D U C T S O X 18" Ø DUCT SOX 20" Ø SPIRAL R.A. 18" Ø SPIRAL S.A. RG-1 SWR-1 250 SWR-1 250 SWR-1 300 SWR-1 200 SWR-1 200 SWR-1 200 SWR-1 200 AHU 1 T T T SWR-1 200 SWR-1 200 SWR-1 200 SWR-1 200 PTAC 1 F-1 F-2 F-3 RG-2 RG-2 INTO MECHANICAL ROOM BEYOND 24" X 12" UP TO MECHANICAL ROOM 8" Ø UP 8" Ø UP 8" Ø UP 8" Ø S.A. 8" Ø S.A. 8" Ø S.A. 10" X 8" S.A. 14" X 10" S.A. 10" X 8" S.A. DS 1 EF 3 14" X 10" S.A. 8" Ø UP CD-1 200 T AHU-1 PTAC 2 OL-2 OL-1 OL-2 20" Ø SPIRAL R.A. 18" Ø SPIRAL S.A. 12 " Ø D U C T S O X 14 " Ø D U C T S O X 18" Ø DUCT SOX F 1 F 2 F 3 10" X 8" S.A. 24 " X 1 2 " S . A . SWR-1 250 SWR-1 250 SWR-1 300 M M M 12 " X 8 " O . A . 10" X 8" O.A. 8" Ø O.A. 24" X 12" S.A. DOWN 10" X 8" AHU 1 BELOW WINDOW SEE ARCHITECTURAL BELOW WINDOW SEE ARCHITECTURAL UH 1 T UH-1 8" Ø 8" Ø TRANSITION AS REQUIRED HVLS 1 HVLS 2 8" Ø S.A. DOWN 8" Ø 10 " x 8 " S . A . 8" Ø S.A. DOWN MOTORIZED DAMPER CONNECTED TO AHU-1 OPERATION MOTORIZED DAMPER CONNECTED TO AHU-1 OPERATION Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C M1.0 HVAC Plan Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-21-2022 Mo u n t a i n W e s t Gate City E NG INE E RI NG S ER V IC E S 3 4 0 E . C L A R K S T . , P O C A T E L L O ,I D 8 3 2 0 1 2 0 8 .2 2 1 .9 5 0 6 PROJECT # 2238 COVE HEATER SCHEDULE MARK QMARK 1201/60 AMPVOLTAGE HEATING INSTALL PER MANUFACTURERS INSTRUCTION NOTES 450 3.7 MANUF. & MODEL NUMBER LENGTH 34" WATTS RCC4512C CH 1 INTEGRAL THERMOSTAT 120/1/60 INSTALL PER MANUFACTURERS INSTRUCTION45034"CH 2 INTEGRAL THERMOSTAT EXHAUST FAN SCHEDULE SYMBOL TYPE C.F.M.S.P.E.WATTS CHAR.R.P.M.CONTROL REMARKS EF 1 EF 2 LIGHTCEILING120/1/608780.4 640 OUT TO WALL LOUVER EF 3 CEILING 120/1/608780.4 640 120/1/60 1620 LIGHT SWITCH BROAN L100 BROAN L100 MAKE / MODEL QMARK 3.7RCC4512C & MODEL FURNACE SCHEDULE MANUF. NUMBER NOTESDESCRIPTIONMARKAFUE O.A.TOTAL CFMOUTPUTCOOLING HEATING M.C.A.VOLTAGEESPHPCFMTONS NOM.SUPPLY FAN MIN. LENNOXEL196UH090XE48C 4 1600 .4 3/4 120/1/60 85,600 48,000 150 96%WITH MATCHING COOLING COILF 1 GAS / ELECTRIC INPUT HEATING 88,000 MOP/ FUEL NG & MODEL CONDENSING UNIT SHEDULE MANUF. NUMBER NOTESTYPEMARK TOTAL MCA COOLING MOP/ LBS.MIN. SEERCOOLING (MBTU/H) SENIBLE / TOTAL LENNOX13ACXN048 42,000 / 48,000 13 195 50 / 31.9 48,000 ON PADCU 1 DX VOLTAGE 208/1/60 WEIGHT LENNOXEL196UH090XE60C 5 1990 .5 1 120/1/60 107,200 52,000 200 96%F 2 GAS / ELECTRIC 110,000NG LENNOX13ACXN060 50,000 / 52,000 13 218 60 / 34.6 57,000 ON PADCU 2 DX 208/1/60 DIFFUSER, GRILLE, & REGISTER SCHEDULE SYMBOL DESCRIPTION NECK NOTESMATERIALPATTERNINSTALLATIONSIZE CD-1 CEILING DIFFUSER STEEL 4 WAY CD-2 STEEL GRILLE SIZE 10 X 10 10 X 10 4 WAY LAY - IN CEILING RG-1 STEEL FIXED BLADE CEILING DIFFUSER RETURN GRILLE DUCT / BEVELED EDGE 8" Ø 22 X 2220" Ø SWR-1 STEEL16 X 1014 X 8WALL DIFFUSER DUCTFIXED BLADE RG-2 STEEL FIXED BLADERETURN GRILLE 22 X 24- LENNOX 13ACXN030 28,000 / 30,000 13 144 25 / 17.1 30,000 ON PADCU 3 DX 208/1/60 LENNOX EL196UH090XE36C 3.5 1400 .3 1/2 120/1/60 63,900 30,000 140 96%F 3 GAS / ELECTRIC 66,000NG OUT TO WALL LOUVER OUT TO WALL LOUVER CEILING 8780.4BROAN L100 & MODEL AIR HANDLING UNIT SCHEDULE MANUF. NUMBER NOTESDESCRIPTIONMARKOUTPUT HEATING FLAVOLTAGEESPHPCFM SUPPLY FAN CAMBRIDGE S800 3450 .44 3 208/3/60 12 587 MBH SEE SIDE INSTALLATION DETAILAHU 1 SPACE HEATER INPUT HEATING 638 MBH FUEL NG AIR CONDITIONER SCHEDULE MARK EER HEATINGCOOLING VOLTAGE MANUF. & MODEL NUMBER COPBTUBTU ELECTRIC HEAT AMP O.A. CFM WIRED T-STAT, WALL SLEEVE, NOTES ARCHITECTURAL OUTDOOR GRILLE (BRONZE) WATTS AMANNA 7,850 230/1/607,700 11.7 310PTC073G35 3.5 KW 20 40PTAC 1 PTAC 2 8" Ø SIDE WALL HARD CEILING / BEVELED EDGE WITH / OBD 8.4/15 10.9/15 6.8/15 UNIT HEATER SCHEDULE MARK DETROIT RADIANT 120/1/60 VOLTAGE HEATING BTU'S WITH SIDE WALL FLUE KIT NOTES 75,000 MANUF. & MODEL NUMBER FUEL NG INPUT UH-75 UH 1 OL-1 ALUMINUM FIXED BLADEINTAKE GRILLE 12 X 12- OL-2 ALUMINUM FIXED BLADERELIEF GRILLE 30 X 30- SIDE WALL SIDE WALL RUSKIN ELF375DX WITH MOTORIZED SD-50 DAMPER -115 V, CONNECTED DUCT SOX SCHEDULE MARK DUCTSOX BY OWNER COLOR HANG INSTALL PER MANUFACTURERS INSTRUCTIONS NOTES 13' MANUFACTURER HEIGHT DS 1 SUSPENSION SKELECORE FTS HARDWARE GALVANIZED CABLE LENGTH SEE DETAIL DIAMETER PER SUBMITTAL CEILING FAN SCHEDULE SYMBOL TYPE AMP CHAR.R.P.M.CONTROL REMARKS FAN COMMANDERCEILING208/3/607.6 VARIABLE MILL FINISH, VERIFY MOUNTING CLERANCES CEILING WIRELESSS RITE HITE REVOLUTION 75 SERIES MAKE / MODEL HVLS 1 HVLS 2 RITE HITE REVOLUTION 75 SERIES TO CEILING WITH MFG. REQUIREMENTS 208/3/607.6 VARIABLE WIRELESSS FAN COMMANDER CFM 3.4 WITH MATCHING COOLING COIL WITH MATCHING COOLING COIL OUTPUT 60,000 HP 1/12 AND WITH MAX. HEIGHT OF CRANE ASSEMBLY VERIFY HANG HEIGHT PLACEMENT ABOVE LIGHTING WIRED T-STAT, WALL SLEEVE, ARCHITECTURAL OUTDOOR GRILLE (BRONZE) AMANNA 7,850 230/1/607,700 11.7 310PTC073G35 3.5 KW 20 403.4 RUSKIN ELF375DX KREUGER SHR WITH / OBD KREUGER SHR KREUGER SHR KREUGER SHR KREUGER SHR TO AHU-1 OPERATION DUCT CONSTRUCTION & HANGER DETAIL DIMENSION OF LONGEST SIDE, INCHES SHEET METAL GAGE (ALL FOUR SIDES) MINIMUM REINFORCING ANGLE SIZE AND MAX LONGITUDINAL SPACING BETWEEN TRANSVERSE JOINTS AND/OR INTERMEDIATE REINFORCING TRANSVERSE REINFORCING, (I) AT JOINTS UP THRU 12 26 NONE REQ'D 26 26 13 - 18 24 NONE REQ'D 24 24 19 - 30 24 1"x1"x1/8" @ 60"-24 DRIVE SLIP HEMMED S SLIP RECOM- MANDED GAGE RECOM- MANDED GAGE (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. METAL FASTENERS - OMARK INSULPING DURO DYNE FASTENERS OR GRIPNAILS. GRIP NAILS SHALL BE INSTALLED BY GRIPNAIL HAMMER GUN OR BY AUTOMATIC FASTENER EQUIPMENT. SELF-TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW HANG DUCTS UP TO 30" WIDTH WITH 1" X 18 GAGE STRAPS @ 10'-0" MAX SPACING STRAPS TO BE TIGHT AGAINST DUCTWORK NO POP RIVETS ALLOWED SHEET METAL DUCT PROVIDE SHEET METAL NOSING OR SLEEVE OVER ANY EXPOSED LINER WHICH FACES THE OPPOSITE DIRECTION AS THE AIRFLOW TOP & BOTTOM SECTION OF LINER SHALL OVERLAP THE SIDES SPACING PER SMACNA (TYP.) DUCT LINER NO MORE THAN 2" FROM EDGE OF LINER ALL ENDS OF LINER TO BE COATED W/ ADHESIVE AND SHALL BE BUTTED FIRMLY TOGETHER NO SCALE VOLUME DAMPER CUT OPENING ACCURATELY FOR SPIN IN (FLARED) FITTING. NOTE: DAMPERS SHOULD NOT BE INSTALLED CLOSER THAN TWO DUCT WIDTHS TO ELBOWS OR INTERSECTIONS. VOLUME DAMPER. PROVIDE CONCEALED CEILING DAMPER REGULATOR BRANCH DUCT TAKE-OFF DETAIL NO SCALE NOTE: PROVIDE AND INSTALL DURO DYNE SPEC-SEAL/QUAD SEAL DAMPER WING NUT ARM CONTINUOUS ROD ROUND DAMPER DETAIL NO SCALE HANGER STRAPS Ø50" MAX. HANGER STRAP 3 8" BOLT SELF TAPPING CADIUM PLATED HEX HEAD SHEET METAL SCREW. STRAPS TO BE TIGHT AGAINST DUCT NOTE: ALL SUPPLY AIR DUCT SHALL BE LINED INTERNALLY AS PER SPECIFICATIONS. NO POP RIVETS ALLOWED ROUND DUCT & STRAP HANGER DETAIL NO SCALE 60" MAX CONCENTRIC VENT TERMINATION DETAIL 18 " M I N . A B O V E AV G . S N O W AC C U M U L A T I O N APPROX. 6" EXHAUST INTAKE 20 GA. GALVANIZED SLEEVE. ALLOW PIPING TO MOVE FREELY THRU SLEEVE. EXHAUST INTAKE FLASHING 20 GA. GALANIZED SHEET METAL STRAPCLAMP SCREW SLEEVE SECURELY TO 2x4 BRACING. SCREW HEAD TO BE INSTALLED INSIDE OF SLEEVE (TYP) ROOF SEE ARCH DRAWINGS NO SCALE 3/16 3/16 MACHINE BOLT AT END OF BRACE HANGER ANGLE STEEL BEAM LUG PLATE 4 X 3/8 X 0'-4" STEEL BEAM LUG PLATE 4 X 3/8 X 0'-4" BRACE ANGLE 1/8 1/8 MACHINE BOLT AT END OF BRACE TYPE A THRU H TYPE A THRU H TYPE MAX. LOAD CAPACITY (lbs) MACHINE BOLT END OF BRACE (in.) SPREADER SIZE ANGLE TO SUPPORTING STRUCTURAL MEMBER A B C D E F G H 1040 1415 1586 2020 2870 4800 7040 9240 3/8 3/8 1/2 1/2 5/8 3/4 7/8 1 C4x5.4 C4x5.4 C5x6.7 C6x8.5 C8x11.5 C9x13.4 C10x15.3 C12x20.7 31/2x21/2x3/8x0 fT 3" LLH 5x3x3/8x0 ft 3" LLH 2, 4x3x3/8x0 ft 4" LLH 2, 5x3x3/8x0 ft 4" LLH 2, 6x31/2x3/8x0 ft 4" LLH 2, 6x3x3/8x0 ft 10" LLH 2, 6x31/2x1/2x0 ft11 1/2LLH 2, 8x4x3/4x1 ft 1 1/2" LLH NOTE: 1. MAXIMUM LOAD CAPACITY IS FOR GENERAL INFORMATION ONLY. 2. LLH = LONG LONG HORIZONTAL SEISMIC CONNECTION TO STRUCTURE NO SCALE Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C M2.0 HVAC Schedules Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-21-2022 Mo u n t a i n W e s t Gate City E NG INE E RI NG S ER V IC E S 3 4 0 E . C L A R K S T . , P O C A T E L L O ,I D 8 3 2 0 1 2 0 8 .2 2 1 .9 5 0 6 PROJECT # 2238 Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C M3.0 ENERGY COMPLIANCE Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-21-2022 Mo u n t a i n W e s t Gate City E NG INE E RI NG S ER V IC E S 3 4 0 E . C L A R K S T . , P O C A T E L L O ,I D 8 3 2 0 1 2 0 8 .2 2 1 .9 5 0 6 PROJECT # 2238 DUCT SOX DETAIL 4" 3" UP 3" VTR 2 V" 2 V"2 V" 3"3" V UP 4" 3" VTR FD-1 4" C O T G 4" WCO 4"4" FS-1 3" VTR 3" V DOWN 2" DOWN 3" VTR F 1 F 2 F 3 CONDENSATE LINE 2" 3/4" 1-1/4" 1-1/4" 2" V Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C P1.0 Sewer & Vent Plan Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-21-2022 Mo u n t a i n W e s t Gate City E NG INE E RI NG S ER V IC E S 3 4 0 E . C L A R K S T . , P O C A T E L L O ,I D 8 3 2 0 1 2 0 8 .2 2 1 .9 5 0 6 PROJECT # 2238 1/2" HWR 1/2" HWR 3/4" DF-1 WC-1 S-1 EW-1 WC-1 S-1 JS-1 S-2 S-3 1-1/2" OUT TO WATER METER SEE CIVIL 6" FIRE LINE RP /PRV STATION 3/4" 3/4" HB-2 HB-2 HB-1 3/4" 3/4" 3/4" 3/4" WH-1 1/2" HWR CP-1 F 1 F 2 F 3 UH 1 AHU 1 G G G G G G G G G G G G G G G G G G GAS REGULATOR (TYPICAL) G 638 MBH @ 2 PSI 3/4" 106 MBH @ 2 PSI 3/4" 1" 304 MBH @ 2 PSI 379 MBH @ 2 PSI 1" 1" 3/4" GAS REGULATOR (TYPICAL) Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C P2.0 Domestic Water Plan Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-21-2022 Mo u n t a i n W e s t Gate City E NG INE E RI NG S ER V IC E S 3 4 0 E . C L A R K S T . , P O C A T E L L O ,I D 8 3 2 0 1 2 0 8 .2 2 1 .9 5 0 6 PROJECT # 2238 PLUMBING FIXTURE SCHEDULE SYMBOL DESCRIPTION COLD HOT VENT WASTE 2" 1/2" FD-1 FLOOR DRAIN: ZURN ZN415 2" 1/2" 1/2"1/2"1-1/2"2" 1/2"2"3" JS-1 IM-1 ICE MAKER BOX: METAL TYPE WITH BALL VALVE MANUFACTURER 50 78 UNIT GAS WATER HEATER SCHEDULE RECOVERY RATE (GPH)AND MODEL CAP (GAL) VOLT /PH 115/1/60 REMARKS BRADFORD/WHITE -RG1PV50S6N FUEL NG BTU/HR INPUT 40,000 UNIFORM ENERGY FACTOR .69WH-1 DRINKING FOUNTAIN: ELKAY BI-LEVEL SIMILAR TO EZSTL8LC 1-1/2"2" HB-1 HOSE BIB: COMMERCIAL GRADE KEY TYPE, WOODFORD MODEL 65 3/4" DF-1 (GPM) RECIRCULATION PUMP SCHEDULE FLOW SERVICEUNIT VOLTAGE(FT) HEAD. HOT WATER RECIRC 1.5 10 AND MODEL MANUFACTURER TACO 006-ST4-PNP115/1/60 HP 1/40CP-1 FS-1 S-1 S-2 S-3 HANDWASH SINK: BIRD BATH STYLE , BRADLEY WF2703 WC-1 WATER CLOSET: AMERICAN STANDARD 215AA.104.020, OPEN SEAT, BALL VALVE, STAINLESS STEEL HOSE 1/2"1/2"1-1/2"2" 1/2"1/2"1-1/2"2" 1/2"1/2"1-1/2"2" 1-1/2"2" RESTROOM SINK: KOHLER K-2005, MOEN 8425 FAUCET, GRID DRAIN,STAINLESS STEEL HOSES, BALL VALVE, ADA PIPE JACKET FLOOR SINK: ZURN FD2375 BREAK ROOM SINK: ELKAY DSEP1515C SINK, MOEN 7864 FAUCET, STAINLESS STEEL HOSES, BALL VALVE, P-TRAP, BASKET STRAINER EW-1 EYE WASH / SHOWER STATION: BRADLEY- S19314BFSS WITH MIXING VALVE FOR TEPID SYSTEM 1/2"1/2" JANITOR SINK: REGENGY 600S/2323X, WITH MOEN 8230 FAUCET AND GRID DRAIN 3/4"HB-2 HOSE BIB: INDOOR TYPE, WOODFORD MODEL 24P FLOOR DRAIN DETAIL 12" TRAP PRIMER CONNECTION OUTLET TO P-TRAP CEMENT BED TILE FLOOR FLOOR DRAIN 1/2" BELOW THE FINISHED GRADE OR THE FINISHED FLOOR CONCRETE FILL STRUCTURAL SLAB ALL FLOOR DRAINS SHALL HAVE A TRAP PRIMER OR A TRAP SEAL. INSTALL DEEP DEEP SEAL P-TRAPS ON ALL FLOOR DRAINS NO SCALECLEANOUTS DETAIL FINISHED FLOOR J.R. SMITH 4020 NICKEL BRONZE TOP FLUSH WITH TOP OF FINISHED FLOOR. BALANCE OF PIPING SAME AS COTG. FLOOR CLEANOUT (FCO) CHROME WALL COVER AND BRASS SCREW FINISHED FLOOR MAY EXTEND AS WASTE OR VENT CLEANOUT TEE WITH PLUG WALL BALANCE OF PIPING SAME AS COTG. WALL CLEANOUT (WCO) CLEANOUT TO GRADE (COTG.) J.R. SMITH 4020 NICKEL BRONZE TOP, FLUSH WITH FINISHED GRADE FINISHED GRADE 16" sq. CONCRETE PAD TROWEL SMOOTH AND BEVEL EDGES. NO SCALE CABLE RESTRAINT PIPE HANGER ROD PIPE INSULATION CABLE RESTRAINT SHEET METAL SADDLE RIGID BLOCK TYPE INSULATIONSIDE VIEW COPPER AND GALV. PIPE SIDE VIEW BLACK PIPE END VIEW END VIEWPROVIDE RIGID BLOCK TYPE PIPE INSULATION AT ALL HANGERS AND SUPPORTS SLEEVE W. I.D. 1/4" LARGER THAN BOLT HANGER HANGER ROD ANGLE BRACKET SEISMIC CABLE RESTRAINT BOLT TO ANGLE ANGLE BRACKET PIPE INSULATION WELD TO PIPE NOTE: SEE STRUCTURAL NOTES FOR DEFERRED SUBMITTAL FOR SEISMIC BRACING FLOOR DRAIN TRAP PRIMER FITTING FINISHED FLOOR 12" (SOFT "K" COPPER NO JOINTS UNDER FLOOR) INSULATE WITH 12" ARMAFLEX INSULATED PIPING SHUT-OFF VALVE TYPICAL FIXTURE AUTOMATIC TRAP PRIMER SUCH AS J.R. SMITH 2699A1-CP WITH VACUUM BREAKER. PRIMER LOCATED IN PLUMING CLOSET. COLD WATER SUPPLY FIXTURE DRAIN ALL PIPE WALL PENETRATIONS SHALL HAVE ESCUTCHEONS TURNBUCKLE THRU-BOLT WOOD JOIST ANGLE EYE- BOLTS I-BEAM CLAMPS U-BOLTS ADJUSTABLE PIPE STAND U-BOLTS ANGLE TURNBUCKLE INSERTS WELDED STEEL WALL BRACKET STEEL OFFSET WALL BRACKET U-BOLTS CINCH ANCHORS (TYP.)U-BOLTS TRAP PRIMER DETAIL NO SCALE PIPE HANGER W/ RESTRAINTS DETAIL NO SCALE TYPICAL PIPE SUPPORT DETAIL NO SCALE HOT WATER RECIRCULATION SCHEMATIC NO SCALE DHR DCW TEMPERED WATER RETURN DOMESTIC COLD WATER 1-1/2" 3/4" 3/4" 3/4" 3/4" LOCKABLE BALL VALVE TO BE LOCKED OPEN BALANCE VALVE THERMOMETER CIRCULATING PUMP WATER HEATER DETAIL NO SCALE WATER HEATER EXPANSION TANK ST-5 ROUTE RELIEF PIPING TO DRAIN PAN BELOW WATER HEATER T & P RELIEF VALVE INSTALL HEAT TRAPS ON WATER HEATER TANK SHUT OFF VALVE (TYPICAL) SET HEATER WITH A 4" DEEP GALVANIZED SHEET METAL DRAIN PAN ROUTE 3/4" COPPER PAN DRAIN LINE TO FLOOR DRAIN BELOW 3/4" 120 ° F H W CIRCULATING PUMP (CP-1) HWR MIXING VALVE WATER PRESSURE REG. STATION DETAIL NO SCALE TO FIXTURES FLOOR 1-1/2" BALL VALVE (TYP.) PRESSURE GAGE, 0-120 PSI, LIQUID FILLED (TYP.) TO S T R E E T 1-1/2" BUILDING WATER LINE 1-1/2" Ø PIPE 1-1/2" Ø 1-1/2" PRESSURE REDUCING VALVE1-1/2" BACKFLOW REDUCE PRESSURE DEVICE NOTE: INSTALL DOUBLE CHECK OR REDUCED PRESSURE BACKFLOW DEVICE AS REQUIRED BY CODE. FIRE RISER DETAIL NO SCALE VANE-TYPE WATERFLOW DETECTOR TEE CONNECTION SYSTEM WATER GAGE STANDARD CHECK VALVE MAIN DRAIN VALVE SUPPLY WATER GAGE AND VALVE TAMPER SWITCH CONTROL VALVEAUTOMATIC DRIP VALVE CHECK VALVE FIRE DEPARTMENT CONNECTION DRAIN OUTLET FOR REFERENCE ONLY. SYSTEM SHALL BE DESIGNED AND BUILT BY AN FIRE SPRINKLER IDAHO LICENSED CONTRACTOR DOUBLE CHECK BACKFLOW VALVE TO LANDSCRAPE STOP & WASTE VALVE IRRIGATION 3/4" Ø VERIFY WITH SITE CONTRACTOR Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C P3.0 Plumbing Schedules Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-21-2022 Mo u n t a i n W e s t Gate City E NG INE E RI NG S ER V IC E S 3 4 0 E . C L A R K S T . , P O C A T E L L O ,I D 8 3 2 0 1 2 0 8 .2 2 1 .9 5 0 6 PROJECT # 2238 ELECTRICAL SPECIFICATIONS 1. INTENT: Provide and install complete and operable electrical systems including but not not limited to; lighting, power, receptacles, data, fire alarm ande etc. Provide all required connections to all Mechanical and Plumbing equipment, as indicated and required, including all conduits, wiring and controls. Coordinate with mechanical contractor and drawings. 2. COMPLIANCE WITH CODES: All work and material shall comply with all applicable codes, safety orders, laws, ordinances and regulations of governing authorities and other agencies having jurisdiction including regulations of the State and Local Fire Marshall, unless detailed as specified to a more restrictive standard or higher requirement. 3. INTERPRETATION OF DRAWINGS: The electrical drawings are essentially diagrammatic in that all provisions necessary to conform to structural, architectural, mechanical and plumbing systems can not be shown. All installations shall be adjusted as necessary to conform and to avoid obstructions, without additional cost to the owner. All work, material and equipment called for by notes, schedules or otherwise indicated on the drawings shall be furnished and isntalled as though fully set forth in these specifications. 4. VISITING THE SITE: Contractor shall visit the site and become acquainted with conditions to be encounterd. Extra funds will not be allowed due to failuer to examine the site and to included existing conditions in bid price. 5. COORDINATION WITH UTILITIES: These plans have been prepared without utility company comments. The contractor shall verify exact requirements for the electrical, telephone and communication services with the utility company representatives and provide all work and pay all costs for a complete and operating systems, as directed by the governing utilities. 6. MATERIALS AND WORKMANSHIP: All workmanship shall be performed by skilled electricians using the best standard practives of the trade. All materials shall, unless otherwise noted, be new and in perfect condition and working order. All material for similar uses shall be of the same type, material and manufacturer for ease of future maintaenance. All equipment shall be readily accessible for maintenance and repairs. All materials, fixtures and equipment shall be covered or sealed upon installation so as to provide for safety and to insure that operation and appearance will be maintained after subsequent construction operations. 7. EXECUTION: Raceway installation: Seperate underground conduits in a common trench 4" minimum horizontally, 12" minimum from other utility lines. Minimum conduit depth shall be 18". Coordinate conduit installation with pipes, steel, footings and ducts installed by other trades. Install conduit runs exposed to view parallel or at right angles to structural members, walls or building lines. Support conduit with one-hole malleable factory made pipe straps, fastended with screws. 8. OPERATING AND ADJUSTING: The owner reserves the right to operate any systems of equipment prior to final comletion and acceptance of the work. Such perliminary operation shall not be construed as an acceptance of any work. Each piece of equipment and all of the systems shall be adjusted to insure proper functioning and shall be left in first class operating condition. 9. CUTTING AND PATCHING: Do all drilling and cutting as necessary for installation of equipment or conduit. Cutting or drilling of structure is only permitted with prior approval of the owner and structural engineer. Where cutting and patching of work is necessary, use the same materials, workmanship and finish to neatly match all surrounding work. 10. CONDUIT: All conduit material and installation methods shall be as allowed by the NEC, local AHJ and as directed by the owner. 11. CONDUCTORS: Type THWN or THHN copper wire insulated for 600V. Smallest wire shall be #14 AWG unless noted otherwise. All wiring shall be Copper unless indicated otherwise. Type MC cable shall be permitted provided it is installed in concealed spaces and installation complies with the Local AHJ and NEC requirements. Use "Ideal Yellow" pulling compound for all wire pulls. Use Scotchlock connectors for all splices in #12 wire and tape bolted pressure connectors for larger wire. 12. GROUNDING: All conduit, branch circuits, feeders and etc. shall be provided with a grounding conductor. All grounding conductors shall be insulated and green in color, size as shown. 13. WIRING DEVICES: Devices shall be Standard type, Specification grade, color as selected by owner. Decora style devices are prohibited. Utilize GFCI and Tamper-proof devices in all locations as defined by the NEC. Wiring devices shall be as installed as allowed by the NEC, local AHJ. 14. DEVICE PLATES: Devices plate type and color shall be as directed by owner and as required by the NEC. 15. LIGHTING FIXTURES: As selected by owner and/or indicated in schedules. All light fixtures shall be installed and connected by the Electrical Contractor. 16. SERVICE EQUIPMENT & PANELBOARDS: Service Equipment: Shall be rated as such and shall comply with local utility co. requirments. . Panelbards: Shall be provided with typed writtend directories indicating loads being served. Maintain all required clearances around equipment as required by the NEC. All equpment dimensions to be field verified. 17. CLEAN-UP: Upon completion of the work, prior to final inspection, thoroughly clean all exposed fixtures, trim and equipment and leave the entire installation in a neat, clean and usable condition. Remove all cement, paint, grease, oil and other foreign substances. 18. TEST: Test all conductors for shorts, opens, grounds or other defects. Correct any defective work and re-test. Demonstrate continuous satisfactory operation of all electrical systems and equipment. Provide training to the owner on electrical systems as needed for owner operation and maintenance of building. 19. GUARANTEE: Prior to final acceptacne of the project, deliver to the owner a written one year guarantee on all workmanship, materials and equipment and agree to repair or replace all such defective items promptly that may occure during the warranty period; including repair or replacement of the premises that may be damaged due to faulty work and materials furnished under contract. ENTRANCE CONDUIT(S) 4" SQUARE BOX RAISED RING TO SUIT WALL RECEPTACLE - 20AMP RATED - SEE SPECIFICATIONS. NORMAL POWER COLOR - (SEE SPEC'S) COVER PLATE - STYLE & COLOR TO BE AS PER SPECIFICATIONS. CIRCUIT NUMBER TO BE WRITTEN ON BACK OF COVER W/FELT-TIP MARKER GREEN INSULATED GROUND CONDUCTOR TEE BAR GRID POWER SUPPLY CONDUIT FOR CEILING OR WALL "J" BOX. SUPPORT WIRE BY ELECTRICAL CONTRACTOR INDEPENDENT OF CEILING SYSTEM. (TYPICAL) ACOUSTIC CEILING TILE SUPPORT CLIPS ALL SIDES CIRCUITING & GENERAL SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION KEYED NOTE REFERENCE1 BRANCH CIRCUIT HOME-RUN TO PANEL INDICATED A-1,3,5 3/4"C.-6#12,1#12G QTY & SIZE OF EQUIPMENT GROUND CONDUCTOR QTY & SIZE OF NEUTRAL AND PHASE CONDUCTOR(S) SIZE OF CONDUIT A-1,3,5 3/4"C.-6#12,1#12G PANEL AND CIRCUIT DESIGNATIONS EQUIPMENT GROUNDING CONDUCTOR TICK MARKS NEUTRAL CONDUCTOR(S) PHASE AND/OR SWITCH-LEG CONDUCTOR(S) BRANCH CIRCUIT/FEEDER CONCEALED IN CEILING OR WALL BRANCH CIRCUIT/FEEDER CONCEALED UNDERGROUND OR FLOOR NEW EQUIPMENT, DEVICES, ETC. EXISTING EQUIPMENT, DEVICES, ETC. DEMOLITION EQUIPMENT, DEVICES, ETC. DETAIL # / SHEET REFERENCE1 / ES101 *25,000A CALCULATED AVAILABLE FAULT CURRENT AT EQUIPMENT(SEE POWER RISER) LIGHTING SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION PARKING AREA POLE LIGHT, SINGLE OR DOUBLE HEAD AS INDICATED ON DRAWINGS. REFER TO LIGHT POLE DETAIL FOR POLE INFORMATION. 2X4 FLUORESCENT OR LED FIXTURE 2X2 FLUORESCENT OR LED FIXTURE SURFACE MOUNTED FLUORESCENT OR LED FIXTURE STRIP FLUORESCENT OR LED FIXTURE WALL MOUNTED FLUORESCENT OR LED FIXTURE EXTERIOR WALL MOUNTED FIXTURE ROUND RECESSED FIXTURE SURFACE OR PENDANT FIXTURE LIGHT FIXTURE SUBSCRIPTS NL NIGHT-LIGHT(CONNECT TO UNSWITCHED LEG OF CIRCUIT) EXIT SIGN, WALL OR CEILING MOUNTING AS REQUIRED (SINGLE OR DOUBLE FACE) DIRECTIONAL CHEVRONS AS INDICATED; CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS THE EXIT SIGNS. SHADED FIXTURE INDICATES AN EMERGENCY FIXTURE. PROVIDE WITH EMERG. BATTERY PACK OR CONNECT TO EMERGENCY POWER SYSTEM (WHERE APPLICABLE). CONNECT BATTERY PACK TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT SERVES THE SAME AREA AS THE EMERGENCY FIXTURE. PROVIDE WITH TEST LIGHT AND SWITCH. CEILING MOUNTED OCCUPANCY SENSOR, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR SENSOR TYPE AND ADDITIONAL INFORMATION. SWITCH MOUNTED OCCUPANCY SENSOR, LOW VOLTAGE SWITCHPOD OR DIMMER SWITCH, REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR TYPE AND ADDITIONAL INFORMATION. SINGLE-POLE SWITCH (SEE SUB-SCRIPTS BELOW FOR ADDITIONAL INFORMATION) SWITCH SUBSCRIPTS 3 3-WAY SWITCH 4 4-WAY SWITCH D DIMMER SWITCH (COMPATIBLE W/ LOAD & LTG TYPES) F 7-DAY PROGRAMMABLE TIMER SWITCH (INTERMATIC MODEL EI500WC SERIES) P PILOT LIGHTED SWITCH F1 LIGHT FIXTURE TYPE DESIGNATION S ### WALL OR CEILING MOUNTED EMERGENCY LIGHTING UNIT W/BATTERY PACK CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS THE EMERGENCY LIGHT. LV LOW-VOLTAGE SWITCH (PER DWG'S) T THERMAL-OVERLOAD SWITCH M SWITCH SUPPLIED WITH EQUIPMENT, INSTALLED BY E.C. WP WEATHERPROOF 2P DOUBLE POLE, SINGLE THROW SWITCH GENERAL LIGHTING NOTES: A. SYMBOLS SHOWN ABOVE MAY NOT REPRESENT ALL LIGHT FIXTURES USED ON PROJECT, REFER TO LIGHT FIXTURE SCHEDULE FOR ACTUAL FIXTURE INFORMATION INCLUDING FIXTURE TYPE, LAMPING, MOUNTING AND ETC. B. JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING". C. IN GENERAL ALL SWITCH-LEG CONDUCTORS MAY NOT BE SHOWN ON DRAWINGS; E.C. SHALL PROVIDE AND INSTALL CONDUCTORS AS REQUIRED TO ACHIEVE CONTROL SCHEMES INDICATED AND DESCRIBED ON DRAWINGS. INCLUDING ALL 0 - 10V DIMMING CONTROLS BETWEEN SWITCH AND FIXTURES. D. ALL BATTERY EXIT SIGNS AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT IN THE AREA. ### F M POWER SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION ELECTRICAL SWITCHBOARD EQUIPMENT, (SEE POWER RISER AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION) 'MSB' 'T##'DRY-TYPE TRANSFORMER, (SEE POWER RISER FOR ADDITIONAL INFORMATION) 'LA' ELECTRICAL PANELBOARD, (SEE POWER RISER AND PANEL SCHEDULES FOR ADDITIONAL INFORMATION) DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X30A/3P/3R FUSED DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X30A/3P/3R (30A FUSES) COMBINATION STARTER & FUSED DISCONNECT SWITCH, SIZE/POLES/TYPE AS INDICATED. TYPES: 1=NEMA 1, 3R=NEMA 3R, 4X=NEMA 4X J JUNCTION BOX CR = CORD REEL; SEE DRAWINGS FOR INFORMATION CD = CORD DROP; SEE DRAWINGS FOR INFORMATION EQUIPMENT CONNECTION; COORDINATE CONNECTION WITH EQUIPMENT PRIOR TO ROUGH-IN MOTOR CONNECTION POWER AND/OR DATA SERVICE POLE FLOORBOX (SEE FLOORBOX SCHEDULE FOR ADDITIONAL INFORMATION) PUSHBUTTON STATION FB# SPECIAL RECEPTACLE (COORDINATE NEMA TYPE WITH EQUIP.) (REFER TO PANEL SCHEDULES FOR AMPS) CEILING MOUNTED DUPLEX RECEPTACLE (COORDINATE PLACEMENT WITH CEILING EQUIPMENT PRIOR TO ROUGH-IN) DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT GFCI-TYPE DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT GFCI-TYPE DOUBLE-DUPLEX RECEPTACLE, UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT. RECEPTACLE AND EQUIPMENT SUBSCRIPTS AC ABOVE COUNTER WP WEATHERPROOF (UL LISTED WEATHER-RESISTANT) 42"MOUNTING HEIGHT AFF OR AFG IG ISOLATED GROUND S SURGE-PROTECTION TYPE REF REFRIGERATOR W WASHING MACHINE D DRYER (30A-240V RATED RECPT.) M MICROWAVE HVAC THERMOSTAT OR SENSOR; PROVIDE & INSTALL BACKBOX,3/4" CONDUIT AND CONDUCTORS TO ASSOCIATED HVAC UNIT. COORDINATE EXACT LOCATION & SIZE AND NUMBER OF CONDUCTORS WITH M.C. T SOR 30A/3P/3R SIZE 1 (30A FUSES) SMALL EXHAUST FAN CONNECTION TV 120V RECEPT. FOR TV; VERIFY HEIGHT WITH ARCH. DRAWINGS & ELEVATIONS USB 120V RECPT. WITH USB CHARGING PORTS EWC ELECTRIC WATER COOLER; (SEE DETAIL. RECPT. SHALL BE ACCESSIBLE, DO NOT MOUNT BEHIND HOUSING.) DISP GARBAGE DISP. (UNDER SINK) DW DISHWASHER (COORDINATE W/ MILLWORK, INSTALL PER NEC 422.16(B)(2)). M/R MICROWAVE/RANGE HOOD (COORDINATE W/ MILLWORK) R ELECTRIC RANGE (50A-240V RATED RECPT.) GENERAL SPECIAL SYSTEM NOTES: A. ALL DEVICES SHOWN AT OR NEAR MILLWORK/CASEWORK SHALL BE COORDINATED WITH THE ARCHITECTURAL ELEVATION DRAWINGS AND MILLWORK INSTALLER TO INSURE PROPER MOUNTING HEIGHTS. CONTRACTOR SHALL ADJUST DEVICES AS NECESSARY IN ORDER TO POSITION DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS OR BE DIRECTLY ABOVE SINKS OR MIDWAY BETWEEN TILEWORK/WALL OR WAINSCOATING, ETC. B. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL A GFCI TYPE RECEPTACLE FOR ALL RECPTACLES SHOWN IN TOILET RMS, BATHROOMS, KITCHENS/SERVING AREAS, ROOFTOP, OUTDOORS OR WITHIN 6FT OF ANY SINK, BASIN, TUB OR FLOOR SINK AND ALL OTHER AREAS DEFINED BY THE NEC. SPECIAL SYSTEMS SYMBOL SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW)_D-X TELEPHONE OUTLET; _= # OF TELEPHONE CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _T-X TELEPHONE/DATA OUTLET; _= # OF TELEPHONE/DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _T/_D-X CEILING MOUNTED DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) _D-X A. COMMUNICATIONS CABLES SHALL HAVE BENDS NO GREATER THAN 90 DEG. B. CONDUITS FOR COMMUNICATIONS CABLING SHALL HAVE A MAXIMUM BEND RADIUS NOT MORE THAN 10X THE DIAMETER OF THE CONDUIT. C. ALL COMMUNICATIONS CONDUITS SHALL BE TERMINATED WITH AN INSULATED NON-METALLIC BUSHING AT BOTH ENDS. D. COMMUNICATIONS CONDUITS SHALL HAVE NO MORE THAN (2) 90'S WITHOUT A PULLBOX. PULL BOXES SHALL BE LOCATED IN ACCESSIBLE LOCATIONS AND SHALL BE SIZED AT LEASED 12X THE LARGEST CONDUIT DIAMETER IN LENGTH AND MIN, 4" DEEP AND 8" WIDE. E. IT SHALL BE THE RESPONSIBILITY OF THE E.C. TO INSURE THAT THE PATHWAY FOR THE DATA CABLING DOES NOT CREATE CABLE LENGTHS TO EXCEEDS THE LENGTH OF 295FT FROM OUTLET TO PATCH PANEL, THIS INCLUDES SERVICE LOOPS AND PATCH CORDS. F. WHERE CABLE TRAY IS UTILIZED IN THE PROJECT. COMMUNICATION CONDUITS ENDING AT THE CABLE TRAY SHALL EXTEND 1" OVER THE SIDE INTO THE TRAY. GENERAL SPECIAL SYSTEM NOTES: ###_D-X SPECIAL SYSTEMS NOTES: 1. UTILIZE 4 11/16" DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING OR DATA RACK, TERMINATE WITH INSULATED THROAT BUSHING. PROVIDE QTY OF CABLES INDICATED FROM OUTLET TO NEAREST TELE/DATA ROOM. SEE DWGS FOR ADDITIONAL INFORMATION. UTILIZE J-HOOKS 3FT ON CENTER FOR SUPPORT OF CABLING WHERE CABLE TRAY IS NOT INSTALLED/SPECIFIED. 2. CONDUIT SIZE ('X' FROM ABOVE); 2=1/2", 3=3/4", 4=1", 5=1-1/4", 6=1-1/2" 3. BLANK (NO LABEL) = 4-11/16" DEEP BOX WITH REQUIRED MUDRING AND 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING/CABLE TRAY, TERMINATE WITH INSULATED THROAT BUSHING, PROVIDE PULL STRING. (UNLESS OTHERWISE NOTED) WALL/FLOOR ELECTRICAL PATHWAY SLEEVE; INSTALL THROUGH WALL OR FLOOR AS INDICATED. SLEEVES SHALL BE ABOVE ACCESSIBLE CEILINGS IN ACCESSIBLE LOCATION, FIELD VERIFY EXACT LOCATION TO AVOID CONFLICT WITH OTHER TRADES AND UTILITIES. IF WALL/FLOOR IS NOT FIRE RATED E.C. MAY UTILIZED EMT CONDUIT SLEEVES OF EQUAL SIZE. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATINGS. (qty) = QUANTITY OF SLEEVES AT LOCATION EP2 = 2" HILTI SPEED SLEEVE CP-653-BA EP4 = 4" HILTI SPEED SLEEVE CP-653-BA ### FB# _D-X ELECTRICAL FLOORBOX REFER TO "ELECTRICAL FLOORBOX SCHEDULE" FOR INFORMATION. _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTES 1,2,3 BELOW) TV AND/OR AV BOX; WITH POWER, DATA AND/OR AV CONNECTIVITY ### = BOX ID: REFER TO "ELECTRICAL AV/TV BOX SCHEDULE" FOR INFORMATION. _= # OF DATA CABLES, X=CONDUIT SIZE (SEE NOTE #2 BELOW) INSTALL CONDUIT (SIZE AS INDICATED) FROM BOX TO NEAREST ACCESSIBLE CEILING SPACE W/ DATA CABLING/TERMINATIONS AS INDICATED ON DRAWINGS. WALL ### FLOOR (qty) (qty) P 1PH 2/C 3/C 3P 3PH 3W 4W AC ADA AFF AFG AIC AL A or AMP ANN AP ATS AV AWG BFG C CATV CB CCTV CKT C CP CT CU DS EA E.C. EM EMT ENT EPO EQUIP EX FA FACP FLA FMC GND G.C. GEN GFI GFP HD HID HOA HP HPS HV HZ IG IMC J-BOX ABBREVIATIONS SINGLE POLE SINGLE-PHASE TWO-CONDUCTOR THREE-CONDUCTOR THREE POLE THREE-PHASE THREE-WIRE FOUR-WIRE ABOVE COUNTER AMERICANS WITH DISABILITIES ACT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERE INTERRUPTING CAPACITY ALUMINUM AMPERE ANNUNCIATOR ACCESS POINT (WIRELESS DATA) AUTOMATIC TRANSFER SWITCH AUDIO VISUAL AMERICAN WIRE GAGE BELOW FINISHED GRADE CEILING MOUNTED CABLE TELEVISION CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION CIRCUIT CONDUIT CONTROL PANEL CURRENT TRANSFORMER COPPER DISCONNECT SWITCH EACH ELECTRICAL CONTRACTOR EMERGENCY ELECTRICAL METALLIC TUBING ELECTRICAL NONMETALLIC TUBING EMERGENCY POWER OFF EQUIPMENT EXISTING FIRE ALARM FIRE ALARM CONTROL PANEL FULL LOAD AMPS FLEXIBLE METAL CONDUIT GROUND GENERAL CONTRACTOR GENERATOR GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT PROTECTION HEAVY DUTY HIGH INTENSITY DISCHARGE HAND-OFF-AUTOMATIC HORSE POWER HIGH PRESSURE SODIUM HIGH VOLTAGE HERTZ ISOLATED GROUND INTERMEDIATE METAL CONDUIT JUNCTION BOX V KVA kW kWh LED LFMC LFNC LTG LV MAX M.C. MCA MCB MCC MDP MH MIN MLO MOCP NA NC NEC NEMA NFPA NIC NL NO NTS OC OH DR OL PB P PNL PT PTZ QTY RCP RMC RNC SCA SCBA SF SPD SPEC SWBD SWGR TL TP TTB TV TYP UG UPS V VA V.I.F. VFD WAP W/ W/O WP XFMR KILOVOLT KILOVOLT AMPERE KILOWATT KILOWATT HOUR LIGHT EMITTING DIODE LIQUID TIGHT FLEXIBLE METAL CONDUIT LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT LIGHTING LOW VOLTAGE MAXIMUM MECH. CONTRACTOR MINIMUM CIRCUIT AMPS MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MANHOLE MINIMUM MAIN LUGS ONLY MAXIMUM OVERCURRENT PROTECTION NOT APPLICABLE NORMALLY CLOSED NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NIGHT LIGHT NORMALLY OPEN NOT TO SCALE ON CENTER OVERHEAD DOOR OVERLOAD PUSHBUTTON PHASE PANEL POTENTIAL TRANSFORMER PAN/TILT/ZOOM QUANTITY REFLECTED CEILING PLAN RIGID METAL CONDUIT RIGID NONMETALLIC CONDUIT SHORT CIRCUIT AMPS STANDARD COLOR BY ARCHITECT SQUARE FOOT (FEET) SURGE PROTECTION DEVICE SPECIFICATION SWITCHBOARD SWITCHGEAR TWIST LOCK TWISTED PAIR TELEPHONE TERMINAL BOARD TELEVISION TYPICAL UNDERGROUND UNINTERRUPTIBLE POWER SUPPLY VOLTS VOLT AMPERE VERIFY IN FIELD VARIABLE FREQUENCY DRIVE WIRELESS ACCESS POINT WITH WITHOUT WEATHERPROOF TRANSFORMER A. E.C. SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL MECHANICAL EQUIPMENT AND ELECTRICAL CONNECTIONS. B. E.C. SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS OR CABINETS. SEE ELECTRICAL EQUIPMENT CLEARANCE DETAIL. C. INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE. ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED. D. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN(S) FOR EXACT FIXTURE LOCATIONS, CEILING TYPES, ETC. E. E.C. SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED FOR ALL ELECTRICAL EQUIPMENT. F. CONFIRM EXACT LOCATIONS OF ALL TELEPHONE/DATA OUTLETS WITH OWNER PRIOR TO ROUGH-IN. G. LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TO DOOR FRAME AS POSSIBLE, SO AS NOT RO INTERFERE WITH ROOM CABINETS, ETC. H. SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. I. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR WORK AND PAY ASSOCIATED FEES. J. MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLING AND ELECTRONIC BALLASTS. K. UNLESS SPECIFICALLY INDICATED OTHERWISE, E.C. SHALL COORDINATE WITH ANY SPECIAL SYSTEMS SUPPLIER/SHOP DRAWINGS; DENTAL, MEDICAL, KITCHEN, SPECIALIZED EQUIPMENT, ETC. FOR THE EXACT ROUGH-IN REQUIREMENTS FOR THEIR EQUIPMENT. ALSO UNLESS INDICATED OTHERWISE, THE E.C. TO BE RESPONSIBLE FOR FINAL ELECTRICAL CONNECTIONS TO ALL SPECIAL EQUIPMENT. L. ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IF ANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. M. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. N. DATA CABLING SYSTEM PRE-INSTALLATION CONFERENCE: 1. E.C. SHALL SCHEDULE A MEETING A MINIMUM OF FIVE CALENDAR DAYS PRIOR TO BEGINNING DATA CABLING INSTALLATION . ATTENDEES SHOULD INCLUDE OWNER’S REP., ENGINEER, GC, EC AND CABLING SUB. REFER TO SECTION 26 6210(1.4)(E) FOR ADDITIONAL INFORMATION. PROJECT GENERAL NOTES: IDAHO POWER CO. ROCKY MOUNTAIN POWER CO. WWW.IDAHOPOWER.COM WWW.ROCKYMOUNTAINPOWER.NET CONTACT: CONTACT: SHELLEY MARTIN (208) 388-5872 DAN KUHL (503) 308-0233 OR DAN KUHL (503) 308-0233 dan.kuhl@evergreen-efficiency.com dan.kuhl@evergreen-efficiency.com UTILITY LIGHTING REBATES & INCENTIVES: IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PREPARE ALL REQUIRED APPLICATIONS AND INFORMATION REQUIRED TO PROVIDE THE OWNER WITH THE MAXIMUM AMOUNT OF REBATE DOLLARS FROM THE LOCAL UTILITY COMPANY. THE ELECTRICAL CONTRACTOR SHALL SUBMIT VERIFICATION OF THE UTILITY COMPANY PRE-APPLICATION APPROVAL PRIOR TO ORDERING ANY MATERIALS. VISIT THE FOLLOWING UTILITY CO. WEBSITES FOR INFORMATION: TYPICAL DEVICE MOUNTING HEIGHTS: GENERAL COORDINATION NOTE: GENERAL DETAIL NOTES: FINISH FLOOR 1' - 6'' THERMOSTAT OR SENSORVERIFY WITH M.C. PRIOR TO LIGHT SW. (OR AS NOTED) * 4' - 0'' * 3' - 6'' (OR AS NOTED) RECEPTACLE @ MILLWORK BACKSPLASH CA B . D I M E N S I O N S PE R A R C H . D E T A I L 6" CABINET * E.C. SHALL COORDINATE ALL DEVICE MOUNTING HGTS. AND EXACT LOCATION WITH ARCHITECTURAL INTERIOR ELEVATIONS REPORT CONFLICTS TO ARCHITECT **PRIOR TO ROUGH-IN** ROUGH-IN. TYPICAL FOR ALL DEVICES MOUNTED ABOVE COUNTER (ie C.O.'S, DATA, PHONE etc.) A. B. C. D. ALL MOUNTING HEIGHTS TYPICAL UNLESS NOTED OTHERWISE. COORDINATE OUTLET HEIGHTS WITH ARCHITECTS MILLWORK DWGS. TO INSURE THAT OUTLETS WILL NOT FALL BEHIND CABINETS, BACKSPLASHES, OR INTERFERE WITH WAINSCOTING, ETC. ALL SWITCHES AND THERMOSTATS TO BE MOUNTED AS CLOSE TO DOOR JAMS AS POSSIBLE. COORDINATE ALL DEVICES WITH ARCHITECTURAL PLANS AND DETAILS. COORDINATE LIGHT SWITCH & OUTLET HEIGHTS WITH ARCHITECTURAL WAINSCOTING AND OR TILE WORK SO AS NOT TO FALL MIDWAY IN THESE FINISHES. FIRE 6' - 8'' FIRE ALARM NOTIFICATION DEVICE FIRE MANUAL PULL STATION HANDLE SHALL BE BETWEEN 42" & 48" AFF CABINET RECEPT. TELE/DATA OUTLET TV OUTLET ELECTRICAL EQUIP. CLEARANCE ELECTRICALEQUIPMENT NO T E # 1 N O T E #4 NOTE#3 NOTE#2 NOTES: 1. THE MINIMUM HEADROOM OF WORKING SPACE SHALL BE 6 1/2FT. 2. THE WIDTH OF THE WORKING SPACE SHALL BE THE WIDTH OF THE EQUIPMENT OR 30", WHICHEVER IS GREATER. THE PANEL DOOR SHALL OPEN AT LEAST 90 DEGREES. 3. ALL CIRCUIT BREAKERS, WHEN IN THIER HIGHEST POSITION, SHALL NOT BE MORE THAN 6FT 7 IN. ABOVE THE FINISHED FLOOR. 4. 3FT CLEARANCE IF 0-150V TO GROUND, 3.5FT CLEARANCE IF 151-600V TO GROUND. 4FT IF EXPOSED LIVE PARTS ON BOTH SIDES OF THE WORKING SPACE. GENERAL NOTES: A. ALL WORKING SPACE CLEARANCES ARE FROM THE FACE OF THE EQUIPMENT. 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers BO O T H Date Sheet No. A r c h i t e c t u r e (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l P L L C Ne w B u i l d i n g f o r : P.E. #:2265 7/20/22 ELECTRICAL SYMBOLS & DETAILS Mo u n t a i n W e s t 07-20-2022 TB D Re x b u r g , I d a h o E0.0 SCALE: NONEARECEPTACLE MOUNTING DETAIL nLIGHT CONTROL SYMBOL SCHEDULE SYMBOL DESCRIPTION nLIGHT CEILING MOUNTED SENSOR, SEE nLIGHT SYSTEM SCHEDULE FOR ADDITIONAL INFORMATION.S n## n##B nLIGHT BACKBONE DEVICE, SEE nLIGHT SYSTEM SCHEDULE FOR ADDITIONAL INFORMATION. n##R nLIGHT RELAY/POWER PACK DEVICE, SEE nLIGHT SYSTEM SCHEDULE FOR ADDITIONAL INFORMATION. n##RP nLIGHT RELAY PANEL, SEE nLIGHT SYSTEM SCHEDULE FOR ADDITIONAL INFORMATION. nLIGHT SWITCH MOUNTED DEVICE, SEE nLIGHT SYSTEM SCHEDULE FOR ADDITIONAL INFORMATION. n## GREEN, CAT-5e PATCH CABLE (LENGTH AS REQUIRED), PLENUM RATED. • CABLE SHALL BE INSTALLED IN 3/4" CONDUIT WHERE IT CANNOT BE INSTALLED IN AN ACCESSIBLE CEILING SPACE. • PROVIDE A MINIMUM OF 2FT SLACK BETWEEN ALL DEVICES AND FIXTURE CONNECTION POINTS. 0-10V DIMMING WIRING, UTILIZE 1/2" CONDUIT WITH (2) #18 AWG. VIOLET FOR POSITIVE, GREY FOR NEGATIVE 1. E.C. SHALL BE RESPONSIBLE FOR PROVIDING ALL LIGHTING CONTROL COMMISSIONING/PROGRAMMING OF ALL nLIGHT COMPONENTS. THE COMMISSIONING/PROGRAMMING SHALL BE DONE BY A nLIGHT CERTIFIED TECHNICIAN. 2. E.C. SHALL NOTIFY OWNER 1-WEEK PRIOR TO COMMISSIONING/PROGRAMMING OF THE SYSTEM SO THAT THE OWNER CAN PROVIDE REPRESENTATIVES DURING THE COMMISSIONING/PROGRAMMING PERIOD. GENERAL LIGHTING NOTES: NOTE: ALL SYMBOLS MAY NOT BE USED SCALE: NONEBRECESSED LIGHT FIXTURE DETAIL FE SCPC WP1 WP1 SCD1 SCD1 SCD1 D1 D2 D2 D2 D2SCD2 S CD2 n4 n4 n4 n4 WD D D1 D1 n1 S CD1 D1 SCD7 1 2 3 4 5 6 7 8 9 10 A B C D (TYP)F4 RR BREAK SERVICE MANAGER SERVICE RR OFFICE PARTS LOBBY GALLERY SHOP F5 F5 NLF1E F1 NLF1E F1 (TYP)F1 (TYP)F1 F6E F6E (TYP)F7 FX1 FX2 FX2 FX1 FX1 FX1 FX1 F6 F6 F7E F7E F7E F6E F6 F6 (TYP)F7 'LA' 'LCP'F3E F3E F3E F3E F3E F3E F3E (TYP)F3 F3E F3E F3E F3E F3E (TYP)F3 (TYP)F3 TO 'LPC' LA-1 1 LA-3 #8's 1 LA-5 #8's 1 LA-13 LA-13 LA-13 LA-13 LA-13 LA-13 LA-13 (TYP)F8 (TYP)F8 F8 (TYP)F8 (TYP)F9 LA-13 LA-13 TO 'LPC' LA-7 1 LA-9 1 F10E 11' -6" F10E 11' -6" F10E 11' -6"FX3 FX3 FX3 F11 18' -0" F11 18' -0" F11 18' -0" F11 18' -0" F11 18' -0" F11 18' -0" F11 18' -0" LA-111 LA-11 LA-11 LA-11 LA-11 LA-11 LA-11 LA-11LA-11LA-11 3 4 A B C D UPPER OFFICE STORAGE F1F1EF1 (TYP)F2 (TYP)F2 LA-15 LA-15 LA-15 AIRCRAFT CABLE "Y" HANGER (TYP BOTH ENDS OF FIXTURE" AIRCRAFT CABLE ANCHORED SECURELY TO STRUCTURE ABOVE LEVEL W/ BOTTOM OF TRUSSES 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers BO O T H Date Sheet No. A r c h i t e c t u r e (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l P L L C Ne w B u i l d i n g f o r : P.E. #:2265 7/20/22 LIGHTING PLANS Mo u n t a i n W e s t 07-20-2022 TB D Re x b u r g , I d a h o E1.0 A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES: KEY NOTES:# 16'8'0"SCALE: 1/8" = 1'-0"1 MAIN FLOOR LIGHTING PLAN LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING VOLTAGE LUMENS COLOR TEMP.(K) MFGR.CATALOG # APPROVED MFGR'S NOTES F1 2X2 LED FLAT PANEL, 0-10V DIMMING, FIELD SWITCHABLE RECESSED 120-277 MED 4000 LITHONIA CPX 2X2 AL07 M4 COOPER 1 F1E 2X2 LED FLAT PANEL,0-10V DIMMING, FIELD SWITCHABLE, EMERG. BATTERY PACK RECESSED 120-277 MED 4000 LITHONIA CPX 2X2 AL07 M4 IE10WCP COOPER 1 F2 HIGHBAY LED, AIRCRAFT CABLE SUSPENSION SUSPENDED 120-277 15000 4000 LITHONIA IBG-15000LM-SEF-PFL-GND-MVOLT-GZ10-40K-80CRI-SCBA-IBGACVH COOPER 1,3 F3 HIGHBAY LED, AIRCRAFT CABLE SUSPENSION SUSPENDED 30FT AFF 120-277 24000 4000 LITHONIA IBG-24000LM-SEF-PFL-GND-MVOLT-GZ10-40K-80CRI-SCBA-IBGACVH COOPER 1,3 F3E HIGHBAY LED, AIRCRAFT CABLE SUSPENSION, EM. BATTERY PACK SUSPENDED 30FT AFF 120-277 24000 4000 LITHONIA IBG-24000LM-SEF-PFL-GND-MVOLT-GZ10-40K-80CRI-SCBA-E10WCP-IBGACVH COOPER 1,3 F4 6" ROUND RECESSED LED CAN, 0-10V DIMMING RECESSED 120-277 2000 4000 LITHONIA LDN6-40/20-LO6AR-LSS-MVOLT-EZ10 COOPER 1 F5 4FT LED SURFACE WRAPAROUND FIXTURE SURFACE 120-277 4000 4000 LITHONIA FML4W 48 AL06 SEF 840 MVOLT COOPER F6 8FT LED STRIP, 0-10V DIMMING SURFACE OR SUSPENDED 120-277 8000 4000 LITHONIA CLX-L96-8000LM-SEF-RDL-MVOLT-GZ10-40K-80CRI COOPER F6E 8FT LED STRIP, 0-10V DIMMING, W/ EM BATTERY PACK SURFACE OR SUSPENDED 120-277 8000 4000 LITHONIA CLX-L96-8000LM-SEF-RDL-MVOLT-GZ10-40K-80CRI-PS1050 COOPER F7 4FT LED STRIP, 0-10V DIMMING SURFACE/ SUSPENDED 120-277 4000 4000 LITHONIA CLX-L48-4000LM-SEF-RDL-MVOLT-GZ10-40K-80CRI COOPER F7E 4FT LED STRIP, 0-10V DIMMING SURFACE/ SUSPENDED 120-277 4000 4000 LITHONIA CLX-L48-4000LM-SEF-RDL-MVOLT-GZ10-40K-80CRI-PS1050 COOPER F8 PENDANT LINEAR LED, AIRCRAFT CABLE SUSPENSION, 0-10V DIMMING SUSPENDED 12FT AFF 120-277 1250LM/FT 4000 FOCAL POINT LTG FSM4LS-FL-1250LF-40K-1C-UNV-LD1-C96**-SCBA-(PER DWG'S) COOPER 1,2,3,4 F9 PENDANT LINEAR LED, AIRCRAFT CABLE SUSPENSION, 0-10V DIMMING SUSPENDED 12FT AFF 120-277 375LM/FT 4000 FOCAL POINT LTG FSM4LS-FL-375LF-40K-1C-UNV-LD1-C96**-SCBA-(PER DWG'S) COOPER 1,2,3,4 F10E EXTERIOR LED WALL PACK, EMERG. BATTERY PACK WALL 120-277 4500 4000 LITHONIA WDGE2 LED-P4-40K-80CRI-VW-MVOLT-E20WC-SCBA COOPER 3 F11 EXTERIOR LED WALL PACK WALL 120-277 18000 4000 LITHONIA WDGE4 LED-P3-40K-80CRI-R3-MVOLT-SCBA COOPER 3 FX1 EXIT SIGN W/ 90MIN BATTERY,THERMOPLASTIC, GREEN LED, SINGLE/DOUBLE FACE WALL OR CEILING 120-277 N/A N/A LITHONIA LQM-S-W-3-G-20/277-EL N COOPER FX2 EXIT SIGN/EM LIGHT COMBO W/ 90MIN BATTERY,THERMOPLASTIC, GREEN LED, SINGLE/DOUBLE FACE WALL OR CEILING 120-277 N/A N/A LITHONIA LHQM LED-G-SD COOPER FX3 WALL MOUNTED EXTERIOR EMERGENCY EGRESS LIGHT, W/HEATER WALL ABOVE DOOR 120-277 N/A N/A LITHONIA AFF-OEL-SCBA-UVOLT-LTP-SDRT-WT-CW DUAL-LITE LIGHTING CONTROL/OCCUPANCY SENSOR SCHEDULE TYPE DESCRIPTION MFGR. CATALOG # NOTES APPROVED EQUALS DIMMER SWITCHES - LINE VOLTAGE D1 LINE VOLTAGE 0-10V DIMMER, ON/OFF/DIMMING PUSH-BUTTONS SENSOR SWITCH sPODMRA-D-** 2,3,4 D2 LINE VOLTAGE 0-10V DIMMER FOR MULTI-WAY OPERATION, ON/OFF/DIMMING PUSH-BUTTONS SENSOR SWITCH sPODMRA MWO-D-** 2,3,4 LIGHTING CONTROL PANELS 'LCP' SURFACE MOUNTED, 8-RELAY DIGITAL RELAY PANEL, W/nLIGHT INTERFACE ACUITY BRANDS ARP INTENC08 NLT/8SPR/MVOLT/SC/SM/DTC 6 COOPER, WATTSTOPPER, LEVITON nLIGHT DEVICES n1 nLIGHT ON/OFF PUSHBUTTON SENSOR SWITCH nPODM 3 n4 nLIGHT ON/OFF PUSHBUTTON, 4-CHANNEL SENSOR SWITCH nPODM-4P 3 OCC. SENSORS - CEILING (LINE VOLTAGE) CD2 DUAL-TECHNOLOGY, LINE VOLTAGE, SMALL MOTION 800W MAX LOAD SENSOR SWITCH CMR PDT 9 COOPER, WATTSOPPER, HUBBELL OCC. SENSORS - CEILING (LOW VOLTAGE) CD1 DUAL-TECHNOLOGY, SMALL MOTION 360 DEGREE COVERAGE, LOW VOLTAGE, W/ISOLATED RELAY SENSOR SWITCH CM PDT 9 R 1 COOPER, WATTSTOPPER, HUBBELL CD7 DUAL-TECHNOLOGY, CORNER MOUNT WIDE VIEW, LOW VOLTAGE, W/ISOLATED RELAY SENSOR SWITCH WV PDT 16 R (KIT) 1 COOPER, WATTSTOPPER, HUBBELL CPC ON/OFF & AUTOMATIC DIMMING PHOTOCELL SENSOR SWITCH CM PC ADC 1 COOPER, WATTSTOPPER, HUBBELL OCC. SENSORS - WALL MOUNTED WDD DUAL-TECHNOLOGY, 0-10V DIMMING SENSOR SWITCH WSX-PDT-D 2,5 COOPER, WATTSTOPPER, HUBBELL WP1 PASSIVE-INFRARED, 1-POLE, NEUTRAL REQUIRED SENSOR SWITCH WSX-** 2 COOPER, WATTSTOPPER, HUBBELL SCALE: 1/8" = 1'-0"2 MEZZANINE FLOOR LIGHTING PLAN 16'8'0" 1 ROUTE CIRCUIT THROUGH LIGHTING CONTROL PANEL (LCP); REFER TO LIGHTING CONTROL/OCCUPANCY SENSOR SCHEDULE FOR ADDITIONAL INFORMATION. PROVIDE ADDITIONAL UN-SWITCH LEG AS NEEDED FOR CONNECTION TO BATTERY PACK OF EMERGENCY FIXTURE(S) (F#E). 1. PROVIDE ADDITIONAL POWER PACKS; SENSOR SWITCH PP20 AS NEED FOR QTY OF OCCUPANCY SENSORS/SWITCHES. 2. DEVICE COLOR SHALL MATCH WIRING DEVICES; REFER TO SPECIFICATIONS. 3. REFER TO MANUFACTURER DOCUMENTATION FOR QTY AND SIZE OF CONDUCTORS BETWEEN LOW VOLTAGE SWITCH, SENSOR(S) AND POWER/RELAY PACKS. 4. PROVIDE SECONDARY RELAY PACK; SENSOR SWITCH SP20 AS NEEDED TO PROVIDE DUAL-LEVEL SWITCHING OF FIXTURES. 5. PROVIDE 0-10V DIMMING CONDUCTORS (GRAY & VIOLET) BETWEEN SWITCH AND LIGHT FIXTURES FOR DIMMING CONTROL. 6. PROGRAM ON/OFF TIMES OF RELAY'S AS DIRECTED BY OWNER. PROVIDE COMMISSIONING AS INDICATED IN GENERAL NOTES BELOW. 7. CUSTOM WALL STATION ENGRAVINGS IS REQUIRED FOR WALL STATION(S) AND SHALL BE SPECIFIED/COORDINATED WITH OWNER AFTER PROGRAMING OF SYSTEM. CONTROL & OCCUPANCY SENSOR SCHEDULE NOTES: • E.C. SHALL BE RESPONSIBLE FOR THE PROGRAMMING/COMMISSIONING OF THE LIGHTING CONTROL SYSTEMS TO FUNCTION AS INDICATED ON THE DRAWINGS AND SHALL INCLUDE ALL REQUIRED COST IN THE BASE BID. FOR AREAS WITH DAYLIGHTING CONTROL, THE DAYLIGHTING SET-POINTS SHALL BE COORDINATED WITH THE OWNER FOR EACH AREA PRIOR TO FINAL PROGRAMMING OF THE DAYLIGHTING SENSOR(S). ALL PROGRAMMING/COMMISSIONING SHALL BE DONE BY A FACTORY CERTIFIED OR TRAINED PERSON. GENERAL LIGHTING CONTROL NOTES: 1. REFER TO DRAWINGS FOR FIXTURES REQUIRED TO HAVE 0-10V OR STEP-LEVEL DIMMING CONTROL. PROVIDE FIXTURE(S) WITH LED DRIVER(S) AND REQUIRED DIMMING/SWITCH-LEG CONDUCTORS BETWEEN SWITCH(ES) AND FIXTURE(S) TO PROVIDE CONTROL AS INDICATED ON DRAWINGS. 2. FIXTURE LENGTH AS INDICATED ON DRAWINGS. 3. SCBA - STANDARD COLOR BY ARCHITECT/OWNER (COORDINATE COLOR WITH ARCHITECT/OWNER PRIOR TO ORDERING.) 4. FIELD ADJUST PENDANT LENGTH AS REQUIRED, VERIFY LENGTH WITH OWNER. LIGHT FIXTURE SCHEDULE NOTES: • LIGHTING FIXTURES INDICATED IN SCHEDULE ARE BASIS OF DESIGN, ALTERNATE MANUFACTURERS SHALL BE PRE-APPROVED BY ADDENDUM. ALTERNATE MANUCATURERS SHALL SUBMIT PER- APPROVALS TO ENGINEER A MINIMUM OF 10 DAYS PRIOR TO PROJECT BID DATE. GENERAL LIGHTING SCHEDULE NOTES: SCALE: NONEALIGHT FIXTURE HIGHBAY MOUNTING DETAIL FE MM T MM T MM T MM T MM T MM T MM T MM T FB2F FB2F FF FP MM T MM T MM T MM T 1 2 3 4 5 6 7 8 9 10 A B C D WP WP WP WP WP WP WP WPWPWPWP WP 1 1 1 1 1111 2 'MDP''LA' 'LB' 'LC' 3 'TTB' WPWPWP 4 (A/E2.0) 5 5 5 5 5 6 6 5 5 5 7 1"C 1"C 42" EWC RR BREAK SERVICE MANAGER SERVICE RR OFFICE PARTS LOBBY GALLERY SHOP 42" AC 48"48"48"48"48"48" 48" 48" 48"48"48"48"48"48" 48" 48" 48" 48" 48" W W WP AIR COMPRESSOR 60 A/NEMA 3R 8 BRIDGE CRANE 60 A/NEMA 1 8 99 CU-1 CU-2 CU -3 LB-14 LB-16#10's LC-14#10's LC-12 LC-10#10's LB-12#10'sLB-18#10's LA-27 LA-17 LA-16 LA-12 LA-12 LA-10 LA-10 LA-10 LA-12 LA-12 LA-14LA-14 LA-12 LA-16 LA-16 LA-18 LA-10 LA-8 LA-8 LA-8 LA-8 LA-28 LA-28 LA-28 LA-12 LA-8 LA-18 LA-18 LA-18 LA-18 LA-20 LA-24 LA-22 LA-6 LA-6 LA-6 LA-20 LA-6 LA-6 LA-20LA-20 LA-22 LA-22 LA-20 LA-24 LA-24 LA-24LA-24 LA-26 LA-22 LA-2LA-2LA-4LA-4LA-6LA-8 LA-10 LA-25 LA-16 LA-24 LA-23 LA-26 LB-2 LB-6 LB-37,39,41#6's LB-6 LB-6 LB-8 LB-8 LB-8 LB-10 LB-10 LB-10 LC-8 LC-8 LC-8 LC-8 LC-6 LC-40,42#6's LC-6 LC-36,38#6's LC-4LC-2 LC-37,39,41#6's LC-2 LC-2 LC-2LB-4 LB-4 LB-4LB-2 LB-2 10 AHU-1 HVLS-1 HVLS-2 MOTORIZED DAMPER LB-8 CONTROL AS DIRECTED BY MECH. CONTRACTOR MOTORIZED DAMPER LB-2 CONTROL AS DIRECTED BY MECH. CONTRACTOR PTAC-1 LA-26 CH-1 CH -2 3 4 A B C D UPPER OFFICE STORAGE WH-1 LA-51,53#10's LA-19 LA-19 LA-19 LA-19 LA-21LA-21 LA-21 LA-21 LA-21 LA-21 F-1 F-2 F-3 CP-1 LA-19 UH-1 LA-19 PTAC-2 6" 3/4" C., 1#6 B.C. GRND. CONNECT TO BLDG. GROUND SYSTEM FINISH FLOOR TYPICAL CONDUITS OUT TO VOICE/ DATA OUTLETS. SEE PLAN FOR SIZE, ETC. (TYPICAL TOP & OR BOTTOM OF BOARD) 4'X8'X3/4" PLYWOOD PRIME & PAINT W/TWO COATS GREY ENAMEL (INSTALL ON WALLS AS INDICATED ON PLANS) ANCHOR SECURELY TO WALL W/ CONST. ADHESIVE. DOUBLE-DUPLEX OUTLET(S) PER PLANS 120V CIRCUIT PER PLANS PULL CORD INCOMING UTILITY SERVICECONDUIT(S) WITH INSULATED BUSHING. SEE SITE PLAN FOR SIZE & QTY GROUND BAR (SQ. D #PK27GTA) COMM. UTILITY CO. EQUIPMENT INSTALL INSULATED BUSHING ON ALL CONDUIT ENDS. TYP TOP & BOTTOM UNISTRUT ANCHOR TYP TOP & BOTTOM WALL MOUNTED RACK ORTRONICS# OR-604045451 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers BO O T H Date Sheet No. A r c h i t e c t u r e (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l P L L C Ne w B u i l d i n g f o r : P.E. #:2265 7/20/22 POWER/DATA PLANS Mo u n t a i n W e s t 07-20-2022 TB D Re x b u r g , I d a h o E2.0 A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM, INCLUDINB BUT NOT LIMITED TO; LIGHTING, POWER, FIRE ALARM, SPECIAL SYSTEMS, ETC. GENERAL NOTES: KEY NOTES:# SCALE: 1/8" = 1'-0"1 MAIN FLOOR POWER/DATA PLAN 16'8'0" 1 CONNECTION TO OVERHEAD DOOR MOTOR, COORDINATE CONNECTION WITH EQUIPMENT PRIOR TO ROUGH-IN. PROVIDE CONDUIT AND CONDUCTORS TO PUSH-BUTTON STATION PER MANUFACTURERS REQUIREMENTS. 2 CT CAN AND METER BASE MOUNTED ON BUILDING. SEE POWER RISER FOR ADDITIONAL INFORMATION. 3 NEW UNDERGROUND SECONDARY; SEE POWER RISER FOR ADDITIONAL INFORMATION. 4 (1) 4" CONDUIT FOR TELECOMMUNICATIONS SERVICE TO BUILDING AND (1) 2" CONDUIT FOR CABLE TV SERVICE TO BUILDING. STUB CONDUITS TO LOCATIONS AS SPECIFIED BY LOCAL TELEPHONE AND CABLE TV PROVIDERS, PROVIDE WITH PULL-STRING. COORDINATE WITH LOCAL UTILITIES AS INDICATED IN GENERAL NOTES 5 INSTALL RECEPTACLE WITHIN 18" OF THE TOP OF THE WINDOW IN ACCORANCE WITH NEC 210.62. 6 CONNECTION TO AUTOMATIC DOORS; FIELD VERIFY CONNECTION LOCATION AND REQUIREMENTS WITH EQUIPMENT INSTALLERS. PROVIDE ALL REQUIRED ROUGH-IN AND CONNECTIONS TO PUSH-BUTTONS IF APPLICABLE. 7 RECEPTACLE(S) AND DATA OUTLET(S) INSTALLED IN MILLWORK. E.C. SHALL ROUTE POWER AND DATA CONDUIT UNDERGROUND AND STUB-UP INTO MILLWORK. FIELD VERIFY EXACT STUP UP LOCATIONS WITH MILLWORK AND OWNER PRIOR TO ROUGH-IN. 8 FUSE DISCONNECT SWITCH PER EQUIPMENT NAMEPLATE. 9 CONNECT EXHAUST FAN TO ROOM LIGHTING CIRCUIT AND CONTROL WITH LIGHTING 10 PROVIDE AND INSTALL (2) 2" SPARE CONDUITS STUB OUT OF BULDING FOR FUTURE WASHBAY BUILDING AND MONUMENT SIGN. E.C. SHALL FIELD VERIFY STUB OUT LOCATION WITH OWNER AND G.C. PRIOR TO INSTALLATION. SCALE: 1/8" = 1'-0"2 MEZZANINE FLOOR POWER/DATA PLAN 16'8'0"SCALE: NONEATELEPHONE TERMINAL BOARD (TTB) DETAIL ELECTRICAL FLOORBOX SCHEDULE ID DESCRIPTION MFGR. FLOORBOX p/n COVERPLATE p/n POWER DEVICES DATA DEVICES NOTES FB2F 2-GANG, MULTI-SERVICE CONCRETE FLOORBOX, W/FLUSH STYLE RECTANGULAR COVER, 3" MIN. POUR HUBBELL CFB2G30CR 24GTCVRXXX (1) DUPLEX RECPT. PER OWNER 1,2,3 1. PROVIDE REQUIRED SUB-PLATES FOR INSTALLATION OF POWER, DATA AND AV DEVICES. 2. E.C. SHALL FIELD LOCATE EXACT PLACEMENT OF FLOORBOX WITH ARCHITECT/OWNER PRIOR TO INSTALLATION. 3. PROVIDE CONDUIT (SIZE AS INDICATED ON DRAWINGS) TO ACCESSIBLE CEILING SPACE FOR ROUTING OF DATA AND/OR LOW VOLTAGE CABLING. FLOORBOX SCHEDULE NOTES: SHOP SPECIAL NOTES: • ALL WIRING METHODS AND DEVICES LOCATED IN SHOP AND AREAS OPEN TO THE SHOP SHALL CONFORM TO NEC ARTICLE 511, SECTION 501.15 and 210.8(B). • ALL SURFACE RACEWAY INSTALLED BELOW 6'-0" AFF SHALL BE RIGID GALVANIZED STEEL CONDUIT. • PROVIDE AND INSTALL CONDUIT SEAL-OFFS TO COMPLY WITH NEC SECTION 511, 501.15 AND LOCAL AHJ. • WHERE PANELS ARE INSTALLED IN SHOP AREA, INSTALLATION SHALL BE IN COMPLIANCE WITH NEC ARCTICAL 511, SECTION 501.15, SECTION 240.24(A) AND LOCAL AHJ REQUIREMENTS. • ALL UNDERGROUND CONDUITS INSTALLED IN SHOP/LNG BAY AREAS SHALL BE INSTALLED IN COMPLIANCE WITH NEC ARTICLE 511 AND SECTION 501.15. FIRE ALARM SYSTEM SHALL BE DESIGN BUILD BY THE ELECTRICAL CONTRACTOR. PROVIDE AND INSTALL AS REQUIRED BY CURRENT ADOPTED INTERNATIONAL FIRE CODE AND LOCAL AHJ REQUIREMENTS. PROVIDE ALL DOCUMENTATION, DRAWINGS, VOLTAGE DROP AND BATTERY CALCULATIONS AND ECT. TO THE CITY FOR PERMITTING AND INSTALLATION. A. NFPA ALLOWS NOTIFICATION APPLIANCES TO BE MOUNTED AT A HEIGHT RANGE BETWEEN 80" TO 96" ABOVE FINISH FLOOR. THE PREFERRED HEIGHT IS 80". IF THIS CONFLICTS WITH OTHER TRADES OR ROOM FURNISHINGS, LOCATE AS CLOSE TO 80" AS POSSIBLE, NOT EXCEEDING 96". ALL NOTIFICATION APPLIANCES IN A COMMON ROOM OR LINE OF SIGHT SHALL BE LOCATED AT A COMMON HEIGHT. B. MOUNT PULL STATIONS AT 46-48" A.F.F. TO THE OPERATING HANDLE TO MEET ADA REQUIREMENTS. C. IN CORRIDORS, NOTIFICATION APPLIANCES MUST BE LOCATED WITHIN 15' FROM ENDS OF CORRIDORS AND A MAXIMUM OF 100' SPACING. D. PROVIDE THE REQUIRED CANDELA RATING OF ALL NOTIFICATION APPLIANCES ACCORDING TO ROOM SIZE,ETC. E. NOTIFICATION APPLIANCES TO BE SYNCHRONIZED TO PROVIDE A 3-3-3 TEMPORAL PATTERN. F. PROVIDE REQUIRED MONITORING OF FIRE SPRINKLER SYSTEM, COORDINATE WITH FIRE SPRINKLER CONTRACTOR. G. ALL HVLS (HIGH VOLUME LOW SPEED) FANS SHALL BE INTERCONNECTED TO FIRE ALARM SYSTEM AND SHUT-DOWN UPON ACTIVATION OF FIRE ALARM. FIRE ALARM SYSTEM DESIGN: MECHANICAL - FURNACE SCHEDULE EQUIP. ID VOLTS PH. HP FLA CIRCUIT FEEDER NOTES F-1 120 V 1 3/4 14 A LA-42 3/4"C.,2#10+1#10G 1,4 F-2 120 V 1 1 16 A LA-44 3/4"C.,2#10+1#10G 1,4 F-3 120 V 1 1/2 10 A LA-46 3/4"C.,2#12+1#12G 1,4 MECHANICAL - CONDENSING UNIT SCHEDULE EQUIP. ID VOLTS PH. MCA MOCP CIRCUIT FEEDER DISCONNECT NOTES CU-1 208 V 1 32 A 50 A LA-48,50 #8'S 60 A/FUSED/3R 2,4 CU-2 208 V 1 35 A 60 A LA-52,54 #6'S 60 A/FUSED/3R 2,4 CU-3 208 V 1 17 A 25 A LA-47,49 #10'S 60 A/FUSED/3R 2,4 1. E.C. SHALL PROVIDE LOCAL DISCONNECT RATED, THERMAL-OVERLOAD SWITCH FOR EQUIPMENT; SWITCH RATING SHALL NOT BE LESS THEN CIRCUIT BREAKER SUPPLYING EQUIPMENT. 2. E.C. SHALL PROVIDE LOCAL DISCONNECT SWITCH FOR EQUIPMENT; SIZE AND TYPE AS INDICATED IN SCHEDULE. IF FUSED DISCONNECT IS SPECIFIED FOR EQUIPMENT, FUSE PER EQUIPMENT NAMEPLATE RATING. 3. EQUIPMENT IS FACTORY SUPPLYED WITH DISCONNECT AND CONVIENENCE OUTLET; E.C. SHALL PROVIDE ALL NECESSARY CONNECTIONS. 4. PROVIDE 1/2" CONDUIT AND CONDUCTORS BETWEEN FURNACE AND CORRESPONDING OUTDOOR CONDENSING UNIT. COORDINATE SIZE AND NUMBER OF CONDUCTORS WITH M.C. PRIOR TO ROUGH-IN. PROVIDE CONNECTION BETWEEN FURNACE AND ASSOCIATED OUTSIDE AIR MOTORIZED DAMPER, COORDINATE WITH M.C. 5. E.C. SHALL INTERLOCK FAN WITH FIRE ALARM SYSTEMS, FAN SHALL DE-ENERGIZED UPON ACTIVATION OF FIRE ALARM SYSTEM, COORDINATE WITH M.C. AND FIRE ALARM INSTALLER. MECHANICAL SCHEDULE NOTES: MECHANICAL - AIR HANDLING UNIT SCHEDULE EQUIP. ID VOLTS PH. HP FLA CIRCUIT FEEDER NOTES AHU-1 208 V 3 3 12 A LC-31,33,35 #12'S 3 MECHANICAL - CEILING FAN SCHEDULE EQUIP. ID VOLTS PH. FLA CONTROL CIRCUIT FEEDER NOTES HVLS-1 208 V 3 6 A WIRELESS CONTROLLER LB-32,34,36 #12'S 5 HVLS-2 208 V 3 6 A WIRELESS CONTROLLER LB-38,40,42 #12'S 5 MECHANICAL - PTAC SCHEDULE EQUIP. ID VOLTS PH. WATTS FLA CIRCUIT FEEDER NOTES PTAC-1 208 V 1 3500 W 17 A LA-39,41 #10'S PTAC-2 208 V 1 3500 W 17 A LA-43,45 #10'S UTILITY XFMR BY ROCKY MOUNTAIN POWER (RMP). PAD AND VAULT PROVIDED AND INSTALLED BY E.C. PER RMP STANDARDS UNDERGROUND SECONDARY; (4) 4" CONDUIT, TRENCHING AND BACKFILL BY ELEC. CONTRACTOR, CONDUCTORS BY UTILITY CO. FAULT CURRENT CALULATIONS WERE BASED ON INFINITE BUS, WITH AN ESTIMATED 300KVA TRANSFORMER WITH A 3.21%Z. PANEL 'LA' MAIN FLOOR UNDERGROUND PRIMARY; (2) 4"CONDUIT, TRENCHING AND BACKFILL BY ELEC. CONTRACTOR, CONDUCTORS BY UTILITY CO. PANEL 'LB' PANEL 'LC' 800A 208Y/120V,3P,4W NEMA 3R CT CAN PANEL 'MDP' GND BAR (3) 3"C., EA. W/4#300 METER BASE & CT CAN PER RMP CO. REQUIREMENTS GROUNDING ELECTRODE SYSTEM M (2) 2" C. FOR FUTURE WASHBAY AND MONUMENT SIGN *25,972A *19,817A *13,443A *6,324A BLDG. STEEL WATER MAIN GROUND BAR AT MAIN TTB GRND RODS STAND-OFF GROUND BAR LOCATED IN ELEC. RM NEXT TO SERVICE EQUIP. GROUND BAR SHALL BE ERICO #EGBA14412CC OR EQUAL. PROVIDE AND INSTALL ALL REQ'D LUGS & TERMINALS. MOUNT VERT. TO CONSERVE AS MUCH WALL SPACE AS POSSIBLE. MAIN SERVICE EQUIPMENT G N NEUTRAL TO GND BOND AT THIS POINT ONLY #3/0 Cu #4 C u CONCRETE ENCASED ELECTRODE 3/ 4 " C . , 1 # 6 C u #3 / 0 C u #3 / 0 C u #2 C u BOND TO FIRE SPRINKLER RISER #3 / 0 C u 13053 STATEOFIDAHOSHAWNA.M E A D ORREGISTEREDRP OFESSIONALENGIN EE R 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 www.payneengineeringinc.com Engineering Inc. Consulting Engineers BO O T H Date Sheet No. A r c h i t e c t u r e (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l P L L C Ne w B u i l d i n g f o r : P.E. #:2265 7/20/22 POWER RISER, SCHEDULES & DETAILS Mo u n t a i n W e s t 07-20-2022 TB D Re x b u r g , I d a h o E3.0 SCALE: 12" = 1'-0"1 POWER RISER DIAGRAM A. THESE PLANS HAVE BEEN PREPARED WITHOUT UTILITY COMPANY COMMENTS. THE E.C. SHALL VERIFY THE EXACT REQUIREMENTS FOR THE ELECTRIC AND TELEPHONE SERVICES WITH THE UTILITY COMPANY REPRESENTATIVES AND PROVIDE ALL WORK AND PAY ALL COSTS FOR A COMPLETE AND OPERATING SYSTEM, AS DIRECTED BY THE GOVERNING UTILITIES. GENERAL NOTES: POWER RISER FEEDER SCHEDULE SOURCE LOAD # OF CONDUIT RUNS CONDUIT SIZE FEEDER SIZE CONDUCTOR TYPE LOAD AMPS FEEDER BREAKER SIZE MDP PANEL LA 1 2" 3-#3/0, 1-#3/0, 1-#6 COPPER 156 A 200 A MDP PANEL LB 1 2" 3-#3/0, 1-#3/0, 1-#6 COPPER 72 A 200 A MDP PANEL LC 1 2" 3-#3/0, 1-#3/0, 1-#6 COPPER 104 A 200 A FEEDER SCHEDULE LEGEND & NOTES QTY & SIZE OF PHASE CONDUCTOR(S) QTY-#PHASE SIZE, QTY-#NEUTRAL SIZE, QTY-#GROUND SIZE QTY & SIZE OF NEUTRAL CONDUCTOR(S) QTY & SIZE OF GROUND CONDUCTOR(S) 1. # OF RUNS INDICATES THE NUMBER OF PARALLEL RUNS FOR THE FEEDER. 2. FEEDER SIZE IN SCHEDULE IS AS INDICATED BELOW: S = SHUNT-TRIP BREAKER G = GFCI BREAKER R = RED HANDLED, LOCK-OUT TYPE A = ARC-FAULT BREAKER GP = GFEPD BREAKER LCP = CRKT TO BE ROUTED THROUGH LTG CONTROL PANEL BRK NOTES: Elec. Heating 12400 VA 100.00% 12400 VA Welder 16000 VA 87.50% 14000 VA Receptacle 18060 VA 77.69% 14030 VA TOTAL EST. DEMAND AMPS:324 A Other 1000 VA 100.00% 1000 VA TOTAL CONN. AMPS.:331 A Motor 49118 VA 107.15% 52632 VA TOTAL EST. DEMAND:116830 VA Lighting 9959 VA 100.00% 9959 VA TOTAL CONN. LOAD:119341 VA HVAC 13978 VA 100.00% 13978 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR EST. DEMAND PANEL TOTALS PANEL LOAD SUMMARY TOTAL AMPS:317 A 313 A 366 A TOTAL LOAD:38.0 kVA 37.5 kVA 43.9 kVA 23 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 24 21 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 22 19 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 20 17 0 -- 1 -- -- PREPARED SPACE 18 15 0 -- 1 -- -- PREPARED SPACE 16 13 SPARE -- 100 A 3 0 -- 1 -- -- PREPARED SPACE 14 11 14990 0 12 9 10630 0 10 7 PANEL LC 200 A 3 11890 0 3 200 A -- SPARE 8 5 19931 9019 6 3 18656 8383 4 1 PANEL LA 200 A 3 17642 8483 3 200 A PANEL LB 2 CKT CIRCUIT DESCRIPTION NOTE AMPS P A B C P AMPS NOTE CIRCUIT DESCRIPTION CKT SERVICE ENTRANCE RATED NOTES: MFG/ MODEL:SQ. D/I-LINE DIMENSIONS:44"W x 11.5"D x *"H FEED:BOTTOM ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:800 A MOUNTING:SURFACE WIRES:4 PANEL AMPS:800 A FED FROM:PHASES:3 PANEL TYPE:MBR Mountain West LOCATION: VOLTAGE:120/208 Wye A.I.C. RATING:42k PROJECT: PANEL: MDP PAYNE ENGINEERING S = SHUNT-TRIP BREAKER G = GFCI BREAKER R = RED HANDLED, LOCK-OUT TYPE A = ARC-FAULT BREAKER GP = GFEPD BREAKER LCP = CRKT TO BE ROUTED THROUGH LTG CONTROL PANEL BRK NOTES: TOTAL ESTIMATED DEMAND AMPS:153 A TOTAL AMPS:147 A 157 A 167 A TOTAL LOAD:17.6 kVA 18.7 kVA 19.9 kVA 53 2250 2912 54 51 Water Heater 30 A 2 2250 2912 2 60 A HVAC 52 49 1414 2662 50 47 HVAC 25 A 2 1414 2662 2 50 A HVAC 48 45 1750 1176 1 20 A Furnace 46 43 PTAC 20 A 2 1750 1920 1 30 A Furnace 44 41 1750 1656 1 25 A Furnace 42 39 PTAC 20 A 2 1750 0 1 20 A -- SPARE 40 37 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 38 35 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 36 33 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 34 31 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 32 29 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 30 27 Overhead Door 20 A 1 1176 540 1 20 A Receptacle 28 25 Elec. Heating/Recpt. 20 A 1 617 622 1 20 A Receptacle 26 23 Elec. Heating/Recpt. 20 A 1 617 1080 1 20 A Receptacle 24 21 Receptacle 20 A 1 1080 720 1 20 A Receptacle 22 19 Receptacle 20 A 1 1293 900 1 20 A Receptacle 20 17 Receptacle 20 A 1 360 900 1 20 A Receptacle 18 15 Lighting 20 A 1 1065 1140 1 20 A Receptacle 16 13 Lighting 20 A 1 1316 1000 1 20 A Automatic Doors 14 11 Lighting - Exterior LCP 20 A 1 1030 1080 1 20 A Receptacle 12 9 Lighting LCP 20 A 1 740 900 1 20 A Receptacle 10 7 Lighting LCP 20 A 1 1425 1080 1 20 A Receptacle 8 5 Lighting - Shop LCP 20 A 1 1500 1080 1 20 A Receptacle 6 3 Lighting - Shop LCP 20 A 1 1500 360 1 20 A Receptacle 4 1 Lighting - Shop LCP 20 A 1 1500 360 1 20 A Receptacle 2 CKT CIRCUIT DESCRIPTION NOTE AMPS P A B C P AMPS NOTE CIRCUIT DESCRIPTION CKT NOTES: MFG & MODEL:SQ. D/NQ SERIES DIMENSIONS:20"W x 5.8"D x *"H FEED:BOTTOM ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A MOUNTING:SURFACE WIRES:4 PANEL AMPS:225 A FED FROM:MDP PHASES:3 PANEL TYPE:MLO Mountain West LOCATION: VOLTAGE:120/208 Wye A.I.C. RATING:22k PROJECT: PANEL: LA PAYNE ENGINEERING S = SHUNT-TRIP BREAKER G = GFCI BREAKER R = RED HANDLED, LOCK-OUT TYPE A = ARC-FAULT BREAKER GP = GFEPD BREAKER LCP = CRKT TO BE ROUTED THROUGH LTG CONTROL PANEL BRK NOTES: TOTAL ESTIMATED DEMAND AMPS:82 A TOTAL AMPS:71 A 70 A 75 A TOTAL LOAD:8.5 kVA 8.4 kVA 9.0 kVA 41 4667 730 42 39 4667 730 40 37 Bridge Crane 60 A 3 4667 730 3 20 A Shop Fan 38 35 PREPARED SPACE -- -- 1 -- 730 36 33 PREPARED SPACE -- -- 1 -- 730 34 31 PREPARED SPACE -- -- 1 -- 730 3 20 A Shop Fan 32 29 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 30 27 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 28 25 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 26 23 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 24 21 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 22 19 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 20 17 SPARE -- 20 A 1 0 1176 1 20 A Overhead Door 18 15 SPARE -- 20 A 1 0 1176 1 20 A Overhead Door 16 13 SPARE -- 20 A 1 0 1176 1 20 A Overhead Door 14 11 SPARE -- 20 A 1 0 1176 1 20 A Overhead Door 12 9 SPARE -- 20 A 1 0 540 1 20 A Receptacle 10 7 SPARE -- 20 A 1 0 590 1 20 A Receptacle 8 5 SPARE -- 20 A 1 0 540 1 20 A Receptacle 6 3 SPARE -- 20 A 1 0 540 1 20 A Receptacle 4 1 SPARE -- 20 A 1 0 590 1 20 A Receptacle 2 CKT CIRCUIT DESCRIPTION NOTE AMPS P A B C P AMPS NOTE CIRCUIT DESCRIPTION CKT NOTES: MFG & MODEL:SQ. D/NQ SERIES DIMENSIONS:20"W x 5.8"D x *"H FEED:BOTTOM ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A MOUNTING:SURFACE WIRES:4 PANEL AMPS:225 A FED FROM:MDP PHASES:3 PANEL TYPE:MLO Mountain West LOCATION: VOLTAGE:120/208 Wye A.I.C. RATING:22k PROJECT: PANEL: LB PAYNE ENGINEERING S = SHUNT-TRIP BREAKER G = GFCI BREAKER R = RED HANDLED, LOCK-OUT TYPE A = ARC-FAULT BREAKER GP = GFEPD BREAKER LCP = CRKT TO BE ROUTED THROUGH LTG CONTROL PANEL BRK NOTES: TOTAL ESTIMATED DEMAND AMPS:107 A TOTAL AMPS:101 A 89 A 127 A TOTAL LOAD:11.9 kVA 10.6 kVA 15.0 kVA 41 3833 4000 42 39 3833 4000 2 50 A G Welder 40 37 Air Compressor 60 A 3 3833 4000 38 35 1441 4000 2 50 A G Welder 36 33 1441 -- 1 -- -- PREPARED SPACE 34 31 Air Handler 20 A 3 1441 -- 1 -- -- PREPARED SPACE 32 29 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 30 27 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 28 25 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 26 23 PREPARED SPACE -- -- 1 -- -- 1 -- -- PREPARED SPACE 24 21 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 22 19 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 20 17 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 18 15 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 16 13 SPARE -- 20 A 1 0 1176 1 20 A Overhead Door 14 11 SPARE -- 20 A 1 0 1176 1 20 A Overhead Door 12 9 SPARE -- 20 A 1 0 1176 1 20 A Overhead Door 10 7 SPARE -- 20 A 1 0 720 1 20 A Receptacle 8 5 SPARE -- 20 A 1 0 540 1 20 A Receptacle 6 3 SPARE -- 20 A 1 0 180 1 20 A Receptacle 4 1 SPARE -- 20 A 1 0 720 1 20 A Receptacle 2 CKT CIRCUIT DESCRIPTION NOTE AMPS P A B C P AMPS NOTE CIRCUIT DESCRIPTION CKT NOTES: MFG & MODEL:SQ. D/NQ SERIES DIMENSIONS:20"W x 5.8"D x *"H FEED:BOTTOM ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A MOUNTING:SURFACE WIRES:4 PANEL AMPS:225 A FED FROM:MDP PHASES:3 PANEL TYPE:MLO Mountain West LOCATION: VOLTAGE:120/208 Wye A.I.C. RATING:10k PROJECT: PANEL: LC PAYNE ENGINEERING SCALE: NONEABLDG GROUNDING ELECTRODE SYSTEM DETAIL In talking with engineer, grounding is to meet 250.66 2017 NEC requirements