HomeMy WebLinkAboutAPPROVED MECHANICAL PLANS - 22-00502 - Mountain West Rental and SalesAuthor Name Author Email Author Phone No.: Don Allen Don.Allen@rexburg.org 208-372-2174 Todd Smith Todd.Smith@rexburg.org 208-372-2181 Description : Mountain West Rental and Sales Address : Record Type : New Commercial Building Document Filename : Mountain West M2.0 REVISION 1-26-22.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 22-00502 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments M2.0 Stamp Don Allen : Mechanical Open 1 Approved - Mechanical Inspector New Commercial Building As per Resolution 2022-07, adopted April 6, 2022, new development is required to follow standards for the installation of fiber conduit and distribution boxes. Location of conduit and distribution boxes need to be identified and shown on plans. Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) COVE HEATER SCHEDULE MARK QMARK 1201/60 AMPVOLTAGE HEATING INSTALL PER MANUFACTURERS INSTRUCTION NOTES 450 3.7 MANUF. & MODEL NUMBER LENGTH 34" WATTS RCC4512C CH 1 INTEGRAL THERMOSTAT 120/1/60 INSTALL PER MANUFACTURERS INSTRUCTION45034"CH 2 INTEGRAL THERMOSTAT EXHAUST FAN SCHEDULE SYMBOL TYPE C.F.M.S.P.E.WATTS CHAR.R.P.M.CONTROL REMARKS EF 1 EF 2 LIGHTCEILING120/1/608780.4 640 OUT TO WALL LOUVER EF 3 CEILING 120/1/608780.4 640 120/1/60 1620 LIGHT SWITCH BROAN L100 BROAN L100 MAKE / MODEL QMARK 3.7RCC4512C & MODEL FURNACE SCHEDULE MANUF. NUMBER NOTESDESCRIPTIONMARKAFUE O.A.TOTAL CFMOUTPUTCOOLING HEATING M.C.A.VOLTAGEESPHPCFMTONS NOM.SUPPLY FAN MIN. LENNOXEL196UH090XE48C 4 1600 .4 3/4 120/1/60 85,600 48,000 150 96%WITH MATCHING COOLING COILF 1 GAS / ELECTRIC INPUT HEATING 88,000 MOP/ FUEL NG & MODEL CONDENSING UNIT SCHEDULE MANUF. NUMBER NOTESTYPEMARK TOTAL MCA COOLING MOP/ LBS.MIN. SEERCOOLING (MBTU/H) SENIBLE / TOTAL LENNOX 13ACXN048 42,000 / 48,000 13 195 50 / 31.9 48,000 ON PADCU 1 DX VOLTAGE 208/1/60 WEIGHT LENNOXEL196UH0110XE60C 5 1990 .5 1 120/1/60 107,200 52,000 200 96%F 2 GAS / ELECTRIC 110,000NG LENNOX13ACXN060 50,000 / 52,000 13 218 60 / 34.6 52,000 ON PADCU 2 DX 208/1/60 DIFFUSER, GRILLE, & REGISTER SCHEDULE SYMBOL DESCRIPTION NECK NOTESMATERIALPATTERNINSTALLATIONSIZE CD-1 CEILING DIFFUSER STEEL 4 WAY CD-2 STEEL GRILLE SIZE 10 X 10 10 X 10 4 WAY LAY - IN CEILING RG-1 STEEL FIXED BLADE CEILING DIFFUSER RETURN GRILLE DUCT / BEVELED EDGE 8" Ø 22 X 2220" Ø SWR-1 STEEL16 X 1014 X 8WALL DIFFUSER DUCTFIXED BLADE RG-2 STEEL FIXED BLADERETURN GRILLE 22 X 24- LENNOX13ACXN042 38,500 / 42,000 13 188 40 / 25.7 42,000 ON PADCU 3 DX 208/1/60 LENNOXEL196UH070XE36B 3.5 1400 .3 1/2 120/1/60 63,900 42,000 140 96%F 3 GAS / ELECTRIC 66,000NG OUT TO WALL LOUVER OUT TO WALL LOUVER CEILING 8780.4BROAN L100 & MODEL AIR HANDLING UNIT SCHEDULE MANUF. NUMBER NOTESDESCRIPTIONMARKOUTPUT HEATING FLAVOLTAGEESPHPCFM SUPPLY FAN CAMBRIDGE S800 3450 .44 3 208/3/60 12 587 MBH SEE SIDE INSTALLATION DETAILAHU 1 SPACE HEATER INPUT HEATING 638 MBH FUEL NG AIR CONDITIONER SCHEDULE MARK EER HEATINGCOOLING VOLTAGE MANUF. & MODEL NUMBER COPBTUBTU ELECTRIC HEAT AMP O.A. CFM WIRED T-STAT, WALL SLEEVE, NOTES ARCHITECTURAL OUTDOOR GRILLE (BRONZE) WATTS AMANNA 7,850 230/1/607,700 11.7 310PTC073G35 3.5 KW 20 40PTAC 1 PTAC 2 8" Ø SIDE WALL HARD CEILING / BEVELED EDGE WITH / OBD 15/8.4 15/10.9 15/6.8 UNIT HEATER SCHEDULE MARK DETROIT RADIANT 120/1/60 VOLTAGE HEATING BTU'S WITH SIDE WALL FLUE KIT NOTES 75,000 MANUF. & MODEL NUMBER FUEL NG INPUT UH-75 UH 1 OL-1 ALUMINUM FIXED BLADEINTAKE GRILLE 12 X 12- OL-2 ALUMINUM FIXED BLADERELIEF GRILLE 30 X 30- SIDE WALL SIDE WALL RUSKIN ELF375DX WITH MOTORIZED SD-50 DAMPER -115 V, CONNECTED DUCT SOX SCHEDULE MARK DUCTSOX BY OWNER COLOR HANG INSTALL PER MANUFACTURERS INSTRUCTIONS NOTES 13' MANUFACTURER HEIGHT DS 1 SUSPENSION SKELECORE FTS HARDWARE GALVANIZED CABLE LENGTH SEE DETAIL DIAMETER PER SUBMITTAL CEILING FAN SCHEDULE SYMBOL TYPE AMP CHAR.R.P.M.CONTROL REMARKS FAN COMMANDERCEILING208/3/607.6 VARIABLE MILL FINISH, VERIFY MOUNTING CLERANCES CEILING WIRELESSS RITE HITE REVOLUTION 75 SERIES MAKE / MODEL HVLS 1 HVLS 2 RITE HITE REVOLUTION 75 SERIES TO CEILING WITH MFG. REQUIREMENTS 208/3/607.6 VARIABLE WIRELESSS FAN COMMANDER CFM 3.4 WITH MATCHING COOLING COIL WITH MATCHING COOLING COIL OUTPUT 60,000 HP 1/12 AND WITH MAX. HEIGHT OF CRANE ASSEMBLY VERIFY HANG HEIGHT PLACEMENT ABOVE LIGHTING WIRED T-STAT, WALL SLEEVE, ARCHITECTURAL OUTDOOR GRILLE (BRONZE) AMANNA 7,850 230/1/607,700 11.7 310PTC073G35 3.5 KW 20 403.4 RUSKIN ELF375DX KREUGER SHR WITH / OBD KREUGER SHR KREUGER SHR KREUGER SHR KREUGER SHR TO AHU-1 OPERATION DUCT CONSTRUCTION & HANGER DETAIL DIMENSION OF LONGEST SIDE, INCHES SHEET METAL GAGE (ALL FOUR SIDES) MINIMUM REINFORCING ANGLE SIZE AND MAX LONGITUDINAL SPACING BETWEEN TRANSVERSE JOINTS AND/OR INTERMEDIATE REINFORCING TRANSVERSE REINFORCING, (I) AT JOINTS UP THRU 12 26 NONE REQ'D 26 26 13 - 18 24 NONE REQ'D 24 24 19 - 30 24 1"x1"x1/8" @ 60"-24 DRIVE SLIP HEMMED S SLIP RECOM- MANDED GAGE RECOM- MANDED GAGE (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. METAL FASTENERS - OMARK INSULPING DURO DYNE FASTENERS OR GRIPNAILS. GRIP NAILS SHALL BE INSTALLED BY GRIPNAIL HAMMER GUN OR BY AUTOMATIC FASTENER EQUIPMENT. SELF-TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW HANG DUCTS UP TO 30" WIDTH WITH 1" X 18 GAGE STRAPS @ 10'-0" MAX SPACING STRAPS TO BE TIGHT AGAINST DUCTWORK NO POP RIVETS ALLOWED SHEET METAL DUCT PROVIDE SHEET METAL NOSING OR SLEEVE OVER ANY EXPOSED LINER WHICH FACES THE OPPOSITE DIRECTION AS THE AIRFLOW TOP & BOTTOM SECTION OF LINER SHALL OVERLAP THE SIDES SPACING PER SMACNA (TYP.) DUCT LINER NO MORE THAN 2" FROM EDGE OF LINER ALL ENDS OF LINER TO BE COATED W/ ADHESIVE AND SHALL BE BUTTED FIRMLY TOGETHER NO SCALE VOLUME DAMPER CUT OPENING ACCURATELY FOR SPIN IN (FLARED) FITTING. NOTE: DAMPERS SHOULD NOT BE INSTALLED CLOSER THAN TWO DUCT WIDTHS TO ELBOWS OR INTERSECTIONS. VOLUME DAMPER. PROVIDE CONCEALED CEILING DAMPER REGULATOR BRANCH DUCT TAKE-OFF DETAIL NO SCALE NOTE: PROVIDE AND INSTALL DURO DYNE SPEC-SEAL/QUAD SEAL DAMPER WING NUT ARM CONTINUOUS ROD ROUND DAMPER DETAIL NO SCALE HANGER STRAPS Ø50" MAX. HANGER STRAP 3 8" BOLT SELF TAPPING CADIUM PLATED HEX HEAD SHEET METAL SCREW. STRAPS TO BE TIGHT AGAINST DUCT NOTE: ALL SUPPLY AIR DUCT SHALL BE LINED INTERNALLY AS PER SPECIFICATIONS. NO POP RIVETS ALLOWED ROUND DUCT & STRAP HANGER DETAIL NO SCALE 60" MAX CONCENTRIC VENT TERMINATION DETAIL 18 " M I N . A B O V E AV G . S N O W AC C U M U L A T I O N APPROX. 6" EXHAUST INTAKE 20 GA. GALVANIZED SLEEVE. ALLOW PIPING TO MOVE FREELY THRU SLEEVE. EXHAUST INTAKE FLASHING 20 GA. GALANIZED SHEET METAL STRAPCLAMP SCREW SLEEVE SECURELY TO 2x4 BRACING. SCREW HEAD TO BE INSTALLED INSIDE OF SLEEVE (TYP) ROOF SEE ARCH DRAWINGS NO SCALE 3/16 3/16 MACHINE BOLT AT END OF BRACE HANGER ANGLE STEEL BEAM LUG PLATE 4 X 3/8 X 0'-4" STEEL BEAM LUG PLATE 4 X 3/8 X 0'-4" BRACE ANGLE 1/8 1/8 MACHINE BOLT AT END OF BRACE TYPE A THRU H TYPE A THRU H TYPE MAX. LOAD CAPACITY (lbs) MACHINE BOLT END OF BRACE (in.) SPREADER SIZE ANGLE TO SUPPORTING STRUCTURAL MEMBER A B C D E F G H 1040 1415 1586 2020 2870 4800 7040 9240 3/8 3/8 1/2 1/2 5/8 3/4 7/8 1 C4x5.4 C4x5.4 C5x6.7 C6x8.5 C8x11.5 C9x13.4 C10x15.3 C12x20.7 31/2x21/2x3/8x0 fT 3" LLH 5x3x3/8x0 ft 3" LLH 2, 4x3x3/8x0 ft 4" LLH 2, 5x3x3/8x0 ft 4" LLH 2, 6x31/2x3/8x0 ft 4" LLH 2, 6x3x3/8x0 ft 10" LLH 2, 6x31/2x1/2x0 ft11 1/2LLH 2, 8x4x3/4x1 ft 1 1/2" LLH NOTE: 1. MAXIMUM LOAD CAPACITY IS FOR GENERAL INFORMATION ONLY. 2. LLH = LONG LONG HORIZONTAL SEISMIC CONNECTION TO STRUCTURE NO SCALE Date Sheet No. Ar c h i t e c t u r e BO O T H (2 0 8 ) 2 3 3 - 4 5 4 8 Ph o n e Po c a t e l l o , I d a h o 8 3 2 0 1 34 0 E a s t C l a r k S t r e e t , S u i t e A (2 0 8 ) 2 3 3 - 0 2 6 3 te d @ b o o t h a r c h i t e c t u r e . c o m Fa x em a i l PL L C M2.0 HVAC Schedules Ne w B u i l d i n g f o r : Re x b u r g , I d a h o TB D 07-26-2022 Mo u n t a i n W e s t Gate City E NG INE E RI NG S ER V IC E S 3 4 0 E . C L A R K S T . , P O C A T E L L O ,I D 8 3 2 0 1 2 0 8 .2 2 1 .9 5 0 6 PROJECT # 2238 REVISION 1 Updated Furnace and Condenser Schedules