HomeMy WebLinkAboutCOMCHECK - 23-00669 - Tagg N Go - Car WashCOMcheck Software Version COMcheckWeb Envelope Compliance Certificate Project Title: 2021 IECC Project Type:New Construction Vertical Glazing / Wall Area:19% Location:Rexburg, Idaho Climate Zone:6b Construction Site: Rexburg, Idaho Owner/Agent: Tagg N Go Car Wash Designer/Contractor: Project Information Energy Code: Tagg N Go Rexburg Credits: 10.0 Required 11.0 Proposed Reduced lighting power, 11.0 credit Additional Efficiency Package(s) Building Area Floor Area 1-Office : Nonresidential 501 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof: Insulation Entirely Above Deck, [Bldg. Use 1 - Office]605 ---48.0 0.021 0.032 Floor: Unheated Slab-On-Grade, Vertical 3 ft., [Bldg. Use 1 - Office] (c) 152 ---10.0 0.510 0.510 NORTH Ext. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Office]668 15.0 10.0 0.043 0.051 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID Kawneer or equivalent, SHGC 0.35, [Bldg. Use 1 - Office] (b) 216 ------0.350 0.340 Door: Glass (over 50 9.56976e-315lazing): Metal Frame, Entrance Door, Perf. Specs.: Product ID Kawneer or Equivalent, SHGC 0.35, [Bldg. Use 1 - Office] (b) 42 ------0.460 0.630 EAST Ext. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Office]162 15.0 10.0 0.043 0.051 Ext. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Office]192 15.0 0.0 0.083 0.051 SOUTH Ext. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Office]446 15.0 10.0 0.043 0.051 Ext. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Office]222 23.0 0.0 0.059 0.051 Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID Kawneer or Equivalent, SHGC 0.35, [Bldg. Use 1 - Office] (b) 66 ------0.350 0.340 Door: Glass (over 50 9.56976e-315lazing): Metal Frame, Entrance Door, Perf. Specs.: Product ID Kawneer or Equivalent, SHGC 0.35, [Bldg. Use 1 - Office] (b) 21 ------0.460 0.630 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Office]21 ------0.200 0.370 WEST Ext. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Office]260 15.0 0.0 0.083 0.051 Ext. Wall: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Office]97 23.0 0.0 0.059 0.051 Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 161 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter 46 ------0.350 0.340 (a) (b) (c) -HIIHU\$9LQFHQW3URMHFW$UFKLWHFW  COMcheck Software Version COMcheckWeb Mechanical Compliance Certificate Project Title: 2021 IECC Project Type:New Construction Location:Rexburg, Idaho Climate Zone:6b Construction Site: Rexburg, Idaho Owner/Agent: Tagg N Go Car Wash Designer/Contractor: Project Information Energy Code: Tagg N Go Rexburg Credits: 10.0 Required 11.0 Proposed Reduced lighting power, 11.0 credit Additional Efficiency Package(s) Mechanical Systems List Quantity System Type & Description Heating: 1 each - Central Furnace, Gas, Capacity = 120 kBtu/h Proposed Efficiency = 81.00% Et, Required Efficiency: 80.00 % Et or 80% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 36 kBtu/h, Air-Cooled Condenser, Unknown Economizer Proposed Efficiency = 14.00 SEER2, Required Efficiency = 13.40 SEER2 Proposed Part Load Efficiency = 0.00 , Required Part Load Efficiency = 0.00 Fan System: FAN SYSTEM 1 | Office -- Compliance (Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 1 Supply, Constant Volume, 1200 CFM, 1.0 motor nameplate hp, 67.00 fan energy index , fan exception: Single fan <= 5HP 1 HVAC System (Single Zone): Heating: 1 each - Radiant Heater, Gas, Capacity = 150 kBtu/h No minimum efficiency requirement applies 1 HVAC System (Single Zone w/ PerimeterSystem): Heating: 1 each - Radiant Heater, Gas, Capacity = 150 kBtu/h No minimum efficiency requirement applies 1 HVAC System (Single Zone w/ PerimeterSystem): Heating: 1 each - Radiant Heater, Gas, Capacity Unknown No minimum efficiency requirement applies 1 HVAC System (Single Zone w/ PerimeterSystem): Heating: 1 each - Radiant Heater, Gas, Capacity Unknown No minimum efficiency requirement applies 1 HVAC System (Single Zone w/ PerimeterSystem): Heating: 1 each - Radiant Heater, Gas, Capacity = 125 kBtu/h No minimum efficiency requirement applies 1 HVAC System (Single Zone w/ PerimeterSystem): Heating: 1 each - Radiant Heater, Gas, Capacity = 125 kBtu/h No minimum efficiency requirement applies 1 HVAC System (Single Zone w/ PerimeterSystem): Heating: 1 each - Unit Heater, Gas, Capacity = 200 kBtu/h Proposed Efficiency = 81.00% Ec, Required Efficiency: 80.00 % Ec Fan System: FAN SYSTEM 2 -- Compliance (Motor nameplate HP and fan efficiency method) : Passes Fans: 1 HVAC System (Unknown w/ PerimeterSystem): Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 163 ofPage Quantity System Type & Description FAN 2 Supply, Constant Volume, 320 CFM, 0.3 motor nameplate hp, 60.00 fan energy index , fan exception: Single fan <= 5HP Heating: 1 each - Other, Electric, Capacity = 18 kBtu/h No minimum efficiency requirement applies Cooling: 1 each - Split System, Capacity = 18 kBtu/h, Air-Cooled Condenser, Unknown Economizer Proposed Efficiency = 0.00 SEER2, Required Efficiency = 13.40 SEER2 Proposed Part Load Efficiency = 0.00 , Required Part Load Efficiency = 0.00 Fan System: FAN SYSTEM 3 -- Compliance (Motor nameplate HP and fan efficiency method) : Passes Fans: FAN 3 Supply, Constant Volume, 600 CFM, 0.2 motor nameplate hp, 67.00 fan energy index , fan exception: Single fan <= 5HP SYSTEM COMPLIANCE FAILS: PROPOSED EFFICIENCY FAILS TO MEET CODE REQUIREMENTS. 1 HVAC System (Single Zone): Electric Storage Water Heater, Capacity: 10 gallons w/ Circulation Pump No minimum efficiency requirement applies 1 Water Heater: Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 164 ofPage Inspection Checklist Requirements: 14.0% were addressed directly in the COMcheck software COMcheck Software Version COMcheckWeb Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2021 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable C103.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical and service water heating systems and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Hot water system sized per manufacturer's sizing guide. Complies Does Not Not Observable Not Applicable C402.4.1 [PR10]1 The vertical fenestration area <= 30 percent of the gross above-grade wall area. Complies Does Not Not Observable Not Applicable C402.4.1 [PR11]1 The skylight area <= 3 percent of the gross roof area. Complies Does Not Not Observable Not Applicable C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 165 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C303.2 [FO4]2 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.2.1 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable C105 [FO3]2 Installed slab-on-grade insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.4 [FO7]2 Slab edge insulation depth/length. Slab insulation extending away from building is covered by pavement or >= 10 inches of soil. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C403.13.2 , C403.13.3 [FO9]3 Snow/ice melting system and freeze protection systems have sensors and controls configured to limit service for pavement temperature above 50F and outdoor temperature above 40F. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 166 ofPage Section # & Req.ID Framing / Rough-In Inspection Complies?Comments/Assumptions C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC certified and as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable C402.4.3 [FR10]1 Vertical fenestration SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3, C402.4.3. 4 [FR8]1 Installed vertical fenestration U-factor and SHGC consistent with label specifications and as reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.5 [FR14]2 U-factor of opaque swinging and nonswinging doors associated with the building thermal envelope meets requirements. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 3 [FR19]1 The building envelope contains a continuous air barrier that is sealed in an approved manner and material permeability <= 0.004 dfm/ft2. Air barrier penetrations are sealed in an approved manner. Complies Does Not Not Observable Not Applicable C402.5.4 [FR18]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 167 ofPage Section # & Req.ID Plumbing Rough-In Inspection Complies?Comments/Assumptions C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable C404.6.1, C404.6.2 [PL3]1 Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. Complies Does Not Not Observable Not Applicable C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable C404.6.1, C404.6.1. 1 [PL8]3 Demand recirculation water systems have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 168 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.2.6 [ME41]3 Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Complies Does Not Not Observable Not Applicable C403.7.7 [ME58]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Reference section language for operational details. Complies Does Not Not Observable Not Applicable C403.8.1 [ME65]3 HVAC fan systems at design conditions do not exceed allowable fan system motor nameplate hp or fan system bhp. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C403.8.3 [ME117]2 Fans have a fan energy index (FEI) >= 1.00. Variable volume fans will have an FEI >= 0.95. Complies Does Not Not Observable Not Applicable C403.8.3 [ME117]2 Fans have a fan energy index (FEI) >= 1.00. Variable volume fans will have an FEI >= 0.95. Complies Does Not Not Observable Not Applicable C403.8.3 [ME117]2 Fans have a fan energy index (FEI) >= 1.00. Variable volume fans will have an FEI >= 0.95. Complies Does Not Not Observable Not Applicable C403.8.3 [ME117]2 Fans have a fan energy index (FEI) >= 1.00. Variable volume fans will have an FEI >= 0.95. Complies Does Not Not Observable Not Applicable C403.8.3 [ME117]2 Fans have a fan energy index (FEI) >= 1.00. Variable volume fans will have an FEI >= 0.95. Complies Does Not Not Observable Not Applicable C403.8.3 [ME117]2 Fans have a fan energy index (FEI) >= 1.00. Variable volume fans will have an FEI >= 0.95. Complies Does Not Not Observable Not Applicable C403.8.4 [ME142]2 Motors for fans that are not less than 1/12 hp and less than 1 hp are electronically commutated motors or have a minimum motor efficiency of 70 percent. These motors have the means to adjust motor speed. Complies Does Not Not Observable Not Applicable C403.8.6 [ME143]2 Each DX cooling system > 65 kBtu and chiller water/evaporative cooling system with fans > 1/4 hp are designed to vary the indoor fan airflow as a function of load and comply with detailed requirements of this section. Complies Does Not Not Observable Not Applicable C403.9 [ME144]2 Large diameter fans where installed shall be tested and labeled in accordance with AMCA 230. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 169 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C403.3 [ME55]2 HVAC equipment efficiency verified.Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C403.2.2 [ME59]1 Natural or mechanical ventilation is provided in accordance with International Mechanical Code Chapter 4. Mechanical ventilation has capability to reduce outdoor air supply to minimum per IMC Chapter 4. Complies Does Not Not Observable Not Applicable C403.7.1 [ME59]1 Demand control ventilation provided for spaces >500 ft2 and >15 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable C403.7.2 [ME115]3 Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. Complies Does Not Not Observable Not Applicable C403.7.6 [ME141]3 HVAC systems serving guestrooms in Group R-1 buildings with > 50 guestrooms: Each guestroom is provided with controls that automatically manage temperature setpoint and ventilation (see sections C403.7.6.1 and C403.7.6.2). Complies Does Not Not Observable Not Applicable C403.7.4 [ME57]1 Exhaust air energy recovery on systems meeting Table C403.7.4(1) and C403.7.4(2). Complies Does Not Not Observable Not Applicable C403.7.5 [ME116]3 Kitchen exhaust systems comply with replacement air and conditioned supply air limitations, and satisfy hood rating requirements and maximum exhaust rate criteria. Complies Does Not Not Observable Not Applicable C403.4.1. 4 [ME63]2 Heating for vestibules and air curtains with integral heating include automatic controls that shut off the heating system when outdoor air temperatures > 45F. Vestibule heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint <= 60F and cooling setpoint >= 80F. Complies Does Not Not Observable Not Applicable C403.3.3 [ME35]1 Hot gas bypass limited to: <=240 kBtu/h – 50% >240 kBtu/h – 25% Complies Does Not Not Observable Not Applicable C408.2.2. 1 [ME53]3 Air outlets and zone terminal devices have means for air balancing. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 1610 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C403.11.3 , C403.11.3 .1, C403.11.3 .2 [ME123]3 Refrigerated display cases, walk-in coolers or walk-in freezers served by remote compressors and remote condensers not located in a condensing unit, have fan-powered condensers that comply with Sections C403.11.3.1 and refrigeration compressor systems that comply with C403.11.3.2.. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 1611 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.7 [EL26]2 Low-voltage dry-type distribution electric transformers meet the minimum efficiency requirements of Table C405.6. Complies Does Not Not Observable Not Applicable C405.8 [EL27]2 Electric motors meet the minimum efficiency requirements of Tables C405.7(1) through C405.7(4). Efficiency verified through certification under an approved certification program or the equipment efficiency ratings shall be provided by motor manufacturer (where certification programs do not exist). Complies Does Not Not Observable Not Applicable C405.9.1, C405.9.2 [EL28]2 Escalators and moving walks comply with ASME A17.1/CSA B44 and have automatic controls configured to reduce speed to the minimum permitted speed in accordance with ASME A17.1/CSA B44 or applicable local code when not conveying passengers. Complies Does Not Not Observable Not Applicable C405.10 [EL29]2 Total voltage drop across the combination of feeders and branch circuits <= 5%. Complies Does Not Not Observable Not Applicable C405.1.1 [EL30]2 At least 90% of dwelling unit permanently installed lighting shall have lamp efficacy >= 65 lm/W or luminaires with efficacy >= 45 lm/W or comply with C405.2.4 or C405.3. Complies Does Not Not Observable Not Applicable C405.11, C405.11.1 [EL31]2 50% of 15/20 amp receptacles installed in enclosed offices, conference rooms, copy rooms, break rooms, classrooms and workstations and > 25% of branch circuit feeders for modular furniture will have automatic receptacle control in accordance with C405.11.1. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 1612 ofPage Section # & Req.ID Insulation Inspection Complies?Comments/Assumptions C303.1 [IN3]1 Roof insulation installed per manufacturer’s instructions and is labeled with R-value or insulation certificate providing R-value and other relevant data. Blown or poured loose- fill insulation is installed only where the roof slope is <=3 in 12. Complies Does Not Not Observable Not Applicable C402.2.1 [IN20]1 Roof assembly meets minimal thermal resistance installed between roof framing or in a continuous fashion on the roof assembly as stipulated in Table C402.1.3. Requirements for above deck insulation, minimum thickness, suspended ceilings, staggered joints and skylight curbs will be met. Complies Does Not Not Observable Not Applicable C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C105 [IN6]1 Installed above-grade wall insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.3 [IN8]2 Installed floor insulation type and R- value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [IN18]3 Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Complies Does Not Not Observable Not Applicable C105 [IN2]1 Installed roof insulation type and R- value consistent with insulation specifications reported in plans and COMcheck reports. For some ceiling systems, verification may need to occur during Framing Inspection. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor- permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 1613 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 3 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C401.3 [FI58]1 A thermal envelope certificate will be supplied and completed by an approved third party. Complies Does Not Not Observable Not Applicable C402.5.10 [FI26]3 Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing. Complies Does Not Not Observable Not Applicable C402.5.11 [FI59]1 Operable openings > 40 ft2 will be interlocked with heating and cooling systems to setback setpoint temperatures within 10 minutes of opening. Complies Does Not Not Observable Not Applicable C402.5.8 [FI37]1 Weatherseals installed on all loading dock cargo door openings and provide direct contact along the top and sides of vehicles parked in the doorway. Complies Does Not Not Observable Not Applicable C403.3.1 [FI27]3 HVAC systems and equipment capacity does not exceed calculated loads. Complies Does Not Not Observable Not Applicable C403.4.1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable C403.4.1. 2 [FI38]3 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable C403.4.1. 3 [FI20]3 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable C403.4.2 [FI39]3 Each zone equipped with setback controls using automatic time clock or programmable control system. Complies Does Not Not Observable Not Applicable C403.4.2. 1, C403.4.2. 2 [FI40]3 Automatic Controls: Setback to 55°F (heat) and 85°F (cool); 7-day clock, 2- hour occupant override, 10-hour backup Complies Does Not Not Observable Not Applicable C403.4.2. 3 [FI41]3 Systems include optimum start controls. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 1614 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C404.3 [FI11]3 Heat traps installed on supply and discharge piping of non-circulating systems. Complies Does Not Not Observable Not Applicable C404.4 [FI25]2 All piping insulated in accordance with section details and Table C403.12.3. Complies Does Not Not Observable Not Applicable C404.6.1 [FI12]3 Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank. System return pipe is a dedicated return pipe or a cold water supply pipe. Complies Does Not Not Observable Not Applicable C406.3 [FI67]1 Reduced lighting power - this credit specifies that the connected lighting power is >= 10% more efficient than 2021 IECC requirements. Complies Does Not Not Observable Not Applicable C408.1.1 [FI57]1 Building operations and maintenance documents will be provided to the owner. Documents will cover manufacturers' information, specifications, programming procedures and means of illustrating to owner how building, equipment and systems are intended to be installed, maintained, and operated. Complies Does Not Not Observable Not Applicable C408.2.1 [FI28]1 Commissioning plan developed by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable C408.2.3. 1 [FI31]1 HVAC equipment, systems and system-to-system relationships have been tested to ensure proper operation. Complies Does Not Not Observable Not Applicable C408.2.3. 2 [FI10]1 HVAC and service water heating control systems have been tested to ensure proper operation, calibration and adjustment of controls. Complies Does Not Not Observable Not Applicable C408.2.4 [FI29]1 Preliminary commissioning report completed and certified by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable C408.2.5 [FI7]3 Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C408.2.5. 1 [FI43]1 An air and/or hydronic system balancing report is provided for HVAC systems. Complies Does Not Not Observable Not Applicable C408.2.5. 2 [FI30]1 Final commissioning report due to building owner within 90 days of receipt of certificate of occupancy. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 1615 ofPage Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Tagg N Go Rexburg 09/19/23Report date: 1616 ofPage