Loading...
HomeMy WebLinkAboutSOIL DENSITY TEST 4 - 22-00610 - U-Haul - New Commercial Bldg APRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BB721797-174C-4273-B274-78A580A39D9D 1 4103 E. 605 N. Suite 1 Rigby ID, 83442 208.932.4428 File Name: 22247D09142023EV In Place Density of Soils ASTM D2922 & D3017 Date: 09/14/2023 Project Number: 22-247 Project Name: U-Haul Moving and Storage Client: Bateman-Hall Total Time on Project: 2 Time Start: 10:00 AM Contractor: Jerome Bowen Construction Current Weather Conditions: Sunny/Clear Wind: Calm Instrument ID 76562 MS: 688 Ambient Temperature (°F): 65 DS: 2665 Results Details Test #: Location:Elevation: Depth:Wet:Dry:% M:Proctor #:% Proctor: Pass Fail 1 Sidewalk north of Building A. 10’ west of NE corner. Top of base BS 130.2 124.6 5.1 130.8 3/4" Base (Edstrom Thorton Pit) 95 2 Sidewalk north of Building A. 80’ west of NE corner. Top of base BS 130.9 125.2 5.3 130.8 3/4" Base (Edstrom Thorton Pit) 96 3 Sidewalk north of Building A. 140’ west of NE corner. Top of base BS 129.0 124.1 3.0 130.8 3/4" Base (Edstrom Thorton Pit) 95 4 Sidewalk north of Building A. 10’ east of NW corner. Top of base BS 130.2 126.2 4.5 130.8 3/4" Base (Edstrom 96 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BB721797-174C-4273-B274-78A580A39D9D 2 Test #: Location:Elevation: Depth:Wet:Dry:% M:Proctor #:% Proctor: Pass Fail Thorton Pit) 5 Sidewalk west of Building A, 70’ south of NW corner. Top of base BS 129.9 124.4 4.4 130.8 3/4" Base (Edstrom Thorton Pit) 95 6 Curb along northern fence in front of Building A. 40’ east of NW corner. Top of base BS 138.2 133.0 3.9 130.8 3/4" Base (Edstrom Thorton Pit) 102 7 Curb along northern fence in front of Building A. 140’ east of NW corner. Top of base BS 139.4 132.5 5.2 130.8 3/4" Base (Edstrom Thorton Pit) 101 8 Curb along northern fence in front of Building A. 180’ east of NW corner. Top of base BS 136.9 132.1 3.6 130.8 3/4" Base (Edstrom Thorton Pit) 101 9 Curb along northern fence in front of Building A. 240’ east of NW corner. Top of base BS 135.3 129.7 4.3 130.8 3/4" Base (Edstrom Thorton Pit) 99 Field Technician Information Truck ROCKET Mileage from Lab to Project (One Way) Total Mileage 650.00 Tested By: Eric Vail Signature: Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. Observations/Remarks: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BB721797-174C-4273-B274-78A580A39D9D 3 I arrived on site and spoke with Mike Massey of Bateman-Hall and he showed me to the areas that needed testing. I also spoke with Gene of Jerome Bowen who confirmed the locations. I tested sidewalk and curb prep around Building A. I found those tests to be passing and I relayed those results back to the appropriate parties. Reviewed By: E. Vail Signature: Inspection Images: