Loading...
HomeMy WebLinkAboutSOIL DENSITY TEST 6 - 22-00269 - Hibbard Elementary SchoolPRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5B52D98C-542A-430A-ACC4-2CCCBE816F5B 1 4103 E. 605 N. Suite 1 Rigby ID, 83442 208.932.4428 File Name: 22229D09112023BF In Place Density of Soils ASTM D2922 & D3017 Date: 09/11/2023 Project Number: 22-229 Project Name: Hibbard Elementary Client: Madison School District Total Time on Project: 5 Time Start: 02:00 PM Contractor: Hill and Sons Current Weather Conditions: Sunny/Clear Wind: 5-15 mph Instrument ID 78653 MS: 643 Ambient Temperature (°F): 78 DS: 2473 Results Details Test #: Location:Elevation: Depth:Wet:Dry:% M:Proctor #:% Proctor: Pass Fail 1 East side of building Base BS 131.1 125.2 4.7 129.9 3/4" Base 96 2 East side of building Base BS 136.5 127.9 6.7 129.9 3/4" Base 98 3 East side of building Base BS 132.6 123.0 7.8 129.9 3/4" Base 95 4 East side of building Base BS 131.6 124.0 6.8 129.9 3/4" Base 95 Field Technician Information Truck GROOT Mileage from Lab to Project (One Way) 13 Total Mileage 13.00 Tested By:Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5B52D98C-542A-430A-ACC4-2CCCBE816F5B 2 Bryton Ferguson Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. Observations/Remarks: Arrived on site a bit earlier than requested but got to watch the crew grade the area to be tested. Once the area was prepped and rolled I began testing. They prepped the east side of the building “fire lane” and my density shots were within general acceptance of the job specific specifications, informed foreman of the results. Reviewed By: E. Vail Signature: Inspection Images: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5B52D98C-542A-430A-ACC4-2CCCBE816F5B 3