HomeMy WebLinkAboutSITE PLAN Rev 2 8.15.23 - 23-00358 - Corcoran 6 Unit Apartments-Reviewed-Corrections-Required (1)Author Name Author Email Author Phone No.:
Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314
Joel Gray Joel.Gray@rexburg.org 208-372-2331
Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164
Katie Saurey Katie.Saurey@rexburg.org 208-372-2167
Description : Corcoran 6 Unit - ApartmentsAddress : 358 S 3rd WApplication Type : Document Filename : SITE PLAN Rev 2 8.15.23 - 23-00358 - Corcoran 6 Unit Apartments.pdf Array
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report Revisions Required
Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments
1 Callout Kyle Baldwin : P&Z Open 1 this maneuvering area behind stall must be 24' wide.
1 Free Text Kyle Baldwin : P&Z Open 1 Waiting on Landscape Plan
1 Free Text Joel Gray : PW Open 1 Storm drainage calculations required.
1 Free Text Joel Gray : PW Open 1 What size of trash receptacle will be used?
1 Free Text Joel Gray : PW Open 1 24 ft maneuvering area required for 90 degree parking.
# 23-00358New Multi-Family Residence
Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved.
Report Date: 08.22.2023
Approval of plans does not constitute approval of variance from code
Page 1 of 1
Powered by TCPDF (www.tcpdf.org)
VICINITY MAP
SCALE: N.T.S.
SUBJECT
PROPERTY
WATERC / W C / W C / W
20'
25'
10'
10'
20'
20'
9'
37'-10"
20'
20'20'-3"
9'8'
5'
S S S S S S
(N) 6 UNIT MULTIFAMILY 4/1
5/2
6/3
11
33
2
6
5
44
5
6
S. 3RD WEST
115.50'
115.50'
82.50'
82.50'
NO
PARKING
STORM
WATER SERVICE
4" SANITARY SEWER
HEATED FIRE RISER &
ALARM PANEL ROOM
TRASH ENCLOSURE
(PERVIOUS PAVERS)
SNOW STORAGE
SNOW STORAGE
(N) SOLID FENCE
CONNECT ROOF
DRAINS TO D.I.
FIRE LANE "NO
PARKING" SIGNAGE
LANDING & SIDEWALK 2% MAX
SLOPE AND CROSS SLOPE
P/L
P/L
P/L
P/L
(E) GARAGE TO
BE REMOVED
(E) DWELLING TO
BE REMOVED
1
A-1
1
A-1
6" CURB WHEEL STOP
(N) STANDARD
HYDRANT
60"60"60"
2
NO
PARKING
5%5%2%
2%2%
2% MAX.
2%2%
MAX. 6" STEP
UP AT CURB
FLUSH
REVISIONS
SHEET:
SCALE:
DATE:
11
8/15/2023
PROJECT DATA:
A.P.N.RPR000P0103610
LOT SIZE .214 ACRES
OCCUPANCY R2
CONSTRUCTION TYPE VB
EXISTING RESIDENCE AREA 969 SF
EXISTING GARAGE AREA 200 SF
(N) 6 UNITS 3,480 SF
UNIT 1 575
UNIT 2 501
UNIT 3 661
UNIT 4 575
UNIT 5 501
UNIT 6 661
SCOPE OF WORK:
REMOVE (E) SINGLE DWELLING,
CONSTRUCT NEW 6 UNIT APARTMENT
BLDG.
SHEET INDEX:
A-1 SITE PLAN
A-2 FLOOR PLANS
A-3 EXTERIOR ELEVATIONS
A-4 BUILDING SECTIONS
S-001 GEN. STRUCTURAL NOTES
S-101 FND PLAN
S-102 2ND FLR FRAMING PLAN
S-103 ROOF FRAMING PLAN
S-501 FND DETAILS
S-510 FLOOR FRAMING DETAILS
S-520 ROOF FRAMING DETAILS
S-601 SCHEDULES
S-602 SCHEDULES
E-1 ELECTRICAL PLANS
SITE PLAN
SCALE: 1" = 10'
JOB NUMBER
CORCORAN 6 UNIT
358 S. 3RD WEST
REXBURG ID
A-1
REFERENCED CODES:
2018 INTERNATIONAL BUILDING CODE
2017 NATIONAL ELECTRICAL CODE
2018 MECHANICAL CODE OF IDAHO
2018 IDAHO COMMERCIAL ENERGY CODE
2018 IECC
2015 IDAHO PLUMBING CODE
2018 INTERNATIONAL FIRE CODE
2009 IDAHO ACCESSIBILITY CODE
DRAWN BY:
DAREN WARDELL
19802 VIA REDONDA RD.
SONORA CA 95370
SNOW STORAGE AREA
PAVED PARKING AREA 4.455 SF
SNOW STORAGE AREA, 493 SF
DEFERRED ITEMS:
1. FIRE SPRINKLERS, NFPA 13R.
SPRINKLERS MUST BE QUICK
RESPONSE
2. ENVELOPE COMM CHECK
1. ACCESSIBLE PATH
SCALE: 1" = 5'
What size of trash receptacle will be used?
2 4 ft m an euv erin g area req uired for 9 0 deg ree park in g .
S torm drain ag e calculation s req uired.
this m an euv erin g area behin d
stall m ust be 2 4 ' wide.
Waitin g on L an dscape P lan