Loading...
HomeMy WebLinkAboutTRUSS SPECS - 23-00358 - Corcoran 6 Unit - ApartmentsJob 232305 Truss A1 Truss Type Common Qty 11 Ply 1 Corcoran Apartments Job Reference (optional) 8.630 s Apr 20 2023 MiTek Industries, Inc. Fri Aug 18 17:04:22 2023 Page 1 Inteframe Components, LLC, Nampa, ID - 83687 ID:lGYcxQBaeSgZ3ivYMlikXMzMpNI-bExXw92X8nw2vewK_qrgf4HoyuMdCvYRlV?pyGymXm7 Scale = 1:47.2 T1 T1 B1 W2 W1 W2 W1 B21 2 3 4 5 6 7 10 9 8 11 12 13 14 15 16 4x6 4x5 3x6 3x4 1.5x4 3x4 1.5x4 4x5 9-3-2 9-3-2 18-2-14 8-11-11 27-6-0 9-3-2 -1-4-0 1-4-0 7-0-3 7-0-3 13-9-0 6-8-13 20-5-13 6-8-13 27-6-0 7-0-3 28-10-0 1-4-0 0- 6 - 1 5- 1 - 1 0- 6 - 1 4.00 12 LOADING (psf) TCLL (Roof Snow=35.0) TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2018/TPI2014 CSI. TC BC WB Matrix-SH 1.00 0.85 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.19 -0.36 0.10 0.08 (loc) 10 6-8 6 8-10 l/defl >999 >910 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 107 lb FT = 15% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF No.1&Btr BOT CHORD 2x4 DF No.2 WEBS 2x4 DF Stud BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 8-9-2 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 2=1537/0-5-8 (min. 0-1-11), 6=1537/0-5-8 (min. 0-1-11) Max Horz2=51(LC 12) Max Uplift2=-124(LC 8), 6=-124(LC 9) Max Grav2=1568(LC 19), 6=1568(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11=-3316/608, 11-12=-3239/615, 3-12=-3135/625, 3-13=-2803/543, 4-13=-2673/551, 4-14=-2673/551, 5-14=-2803/543, 5-15=-3135/625, 15-16=-3239/615, 6-16=-3316/608 BOT CHORD 2-10=-504/3032, 9-10=-295/1988, 8-9=-295/1988, 6-8=-504/3032 WEBS 4-8=-77/1010, 5-8=-748/228, 4-10=-77/1010, 3-10=-748/228 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=22ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Exterior(2E) -1-4-0 to 1-8-0, Interior(1) 1-8-0 to 10-9-0, Exterior(2R) 10-9-0 to 16-9-0, Interior(1) 16-9-0 to 25-10-0, Exterior(2E) 25-10-0 to 28-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 35.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=124, 6=124. 8) This truss is designed in accordance with the 2018 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 232305 Truss A1E Truss Type Common Supported Gable Qty 1 Ply 1 Corcoran Apartments Job Reference (optional) 8.630 s Apr 20 2023 MiTek Industries, Inc. Fri Aug 18 17:04:24 2023 Page 1 Inteframe Components, LLC, Nampa, ID - 83687 ID:lGYcxQBaeSgZ3ivYMlikXMzMpNI-Xd3HLr3ogOAm8y3i5Ft8kVNL0hDAguKjDpUw09ymXm5 Scale = 1:47.2 T1 T1 B1 ST8ST7ST6ST5ST4ST3ST2ST1 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 B212 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 38 39 40 41 3x6 3x4 5x6 3x4 27-6-0 27-6-0 -1-4-0 1-4-0 13-9-0 13-9-0 27-6-0 13-9-0 28-10-0 1-4-0 0- 6 - 1 5- 1 - 1 0- 6 - 1 4.00 12 Plate Offsets (X,Y)-- [11:0-3-0,Edge], [28:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=35.0) TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.13 0.07 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 20 21 20 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 140 lb FT = 15% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF No.2 BOT CHORD 2x4 DF No.2 OTHERS 2x4 DF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 27-6-0. (lb) - Max Horz2=51(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 31, 32, 33, 34, 35, 36, 37, 28, 27, 26, 25, 24, 23, 22, 20 Max Grav All reactions 250 lb or less at joint(s) 30, 31, 32, 33, 34, 35, 36, 29, 28, 27, 26, 25, 24, 23 except 2=298(LC 1), 37=348(LC 1), 22=349(LC 1), 20=297(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-37=-266/99, 19-22=-266/99 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=22ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Corner(3E) -1-4-0 to 1-8-0, Exterior(2N) 1-8-0 to 10-9-0, Corner(3R) 10-9-0 to 16-9-0, Exterior(2N) 16-9-0 to 25-10-0, Corner(3E) 25-10-0 to 28-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 35.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 31, 32, 33, 34, 35, 36, 37, 28, 27, 26, 25, 24, 23, 22, 20. 12) This truss is designed in accordance with the 2018 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 232305 Truss A2 Truss Type Common Qty 22 Ply 1 Corcoran Apartments Job Reference (optional) 8.630 s Apr 20 2023 MiTek Industries, Inc. Fri Aug 18 17:04:27 2023 Page 1 Inteframe Components, LLC, Nampa, ID - 83687 ID:lGYcxQBaeSgZ3ivYMlikXMzMpNI-yCkQzs6gzJYL?QoHnNQrM8?ijv8Nt5uAvniadUymXm2 Scale = 1:47.2 T1 T1 B1 W3 W4 W5W2W1 B3B212 3 4 5 6 7 12 11 10 9 8 13 14 15 16 17 18 19 4x6 3x4 3x6 3x8 3x4 1.5x4 3x6 4x6 3x6 3x4 4-3-0 4-3-0 13-9-0 9-6-0 23-1-4 9-4-4 27-6-0 4-4-12 -1-4-0 1-4-0 7-0-3 7-0-3 13-9-0 6-8-13 20-5-13 6-8-13 27-6-0 7-0-3 28-10-0 1-4-0 0- 6 - 1 5- 1 - 1 0- 6 - 1 4.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-11], [6:0-0-0,0-0-11] LOADING (psf) TCLL (Roof Snow=35.0) TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.81 0.55 0.65 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.14 -0.29 0.05 0.05 (loc) 8-10 8-10 6 8-10 l/defl >999 >940 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 115 lb FT = 15% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF No.1&Btr BOT CHORD 2x4 DF No.1&Btr WEBS 2x4 DF Stud *Except* W2: 2x4 DF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 2-12. WEBS 1 Row at midpt 5-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 6=1269/0-5-8 (min. 0-1-8), 12=1810/0-3-8 (min. 0-2-0) Max Horz12=51(LC 12) Max Uplift6=-118(LC 9), 12=-227(LC 8) Max Grav6=1381(LC 20), 12=1846(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-13=-942/954, 13-14=-934/1077, 3-14=-925/1101, 3-15=-1458/166, 4-15=-1389/183, 4-16=-1421/183, 5-16=-1566/175, 5-17=-2760/272, 17-18=-2859/261, 6-18=-2945/254 BOT CHORD 2-19=-935/942, 12-19=-935/942, 11-12=-47/801, 10-11=-47/801, 9-10=-266/2496, 8-9=-266/2496, 6-8=-175/2677 WEBS 4-10=0/404, 5-10=-1227/288, 5-8=0/463, 3-10=-234/696, 3-12=-2368/997 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=22ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Exterior(2E) -1-4-0 to 1-8-0, Interior(1) 1-8-0 to 10-9-0, Exterior(2R) 10-9-0 to 16-9-0, Interior(1) 16-9-0 to 25-10-0, Exterior(2E) 25-10-0 to 28-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 35.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=118, 12=227. 8) This truss is designed in accordance with the 2018 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 232305 Truss A2E Truss Type Common Supported Gable Qty 2 Ply 1 Corcoran Apartments Job Reference (optional) 8.630 s Apr 20 2023 MiTek Industries, Inc. Fri Aug 18 17:04:29 2023 Page 1 Inteframe Components, LLC, Nampa, ID - 83687 ID:lGYcxQBaeSgZ3ivYMlikXMzMpNI-uasAOY7wUxo3EjyguoTJRZ4CoixNL8KSM5BhhNymXm0 Scale = 1:47.2 T1 T1 B1 ST6ST5ST4ST3ST2 ST1 ST6 ST5 ST4 ST3 ST2 ST1 B212 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 30 29 28 27 26 25 24 23 22 21 20 19 18 31 32 3x6 3x4 3x6 3x4 27-6-0 27-6-0 -1-4-0 1-4-0 13-9-0 13-9-0 27-6-0 13-9-0 28-10-0 1-4-0 0- 6 - 1 5- 1 - 1 0- 6 - 1 4.00 12 Plate Offsets (X,Y)-- [9:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=35.0) TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.13 0.07 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 17 17 16 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 123 lb FT = 15% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF No.2 BOT CHORD 2x4 DF No.2 OTHERS 2x4 DF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 27-6-0. (lb) - Max Horz2=51(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 26, 27, 28, 29, 30, 22, 21, 20, 19, 18, 16 Max Grav All reactions 250 lb or less at joint(s) 25, 29, 24, 19 except 2=274(LC 1), 26=296(LC 19), 27=283(LC 19), 28=285(LC 19), 30=271(LC 1), 22=296(LC 20), 21=283(LC 20), 20=285(LC 20), 18=271(LC 1), 16=274(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 7-26=-255/108, 11-22=-255/108 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=22ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Corner(3E) -1-4-0 to 1-8-0, Exterior(2N) 1-8-0 to 10-9-0, Corner(3R) 10-9-0 to 16-6-4, Exterior(2N) 16-6-4 to 25-10-0, Corner(3E) 25-10-0 to 28-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 35.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 26, 27, 28, 29, 30, 22, 21, 20, 19, 18, 16. 12) This truss is designed in accordance with the 2018 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 232305 Truss A3E Truss Type GABLE Qty 2 Ply 1 Corcoran Apartments Job Reference (optional) 8.630 s Apr 20 2023 MiTek Industries, Inc. Fri Aug 18 17:04:30 2023 Page 1 Inteframe Components, LLC, Nampa, ID - 83687 ID:lGYcxQBaeSgZ3ivYMlikXMzMpNI-MnQYcu8YFEwwstXsSW_Y_mdGb6A24YrcblxEEpymXm? Scale = 1:47.2 T1 T1 B1 ST6ST5 ST4 ST3ST2ST1 ST5 ST4 ST3 ST2 ST1 B212 3 4 5 6 7 8 9 10 11 12 13 14 15 27 26 25 24 23 22 21 20 19 18 17 16 28 29 30 4x5 3x4 4x6 3x4 4-3-0 4-3-0 27-6-0 23-3-0 -1-4-0 1-4-0 13-9-0 13-9-0 27-6-0 13-9-0 28-10-0 1-4-0 0- 6 - 1 5- 1 - 1 0- 6 - 1 4.00 12 Plate Offsets (X,Y)-- [20:0-3-0,0-1-4] LOADING (psf) TCLL (Roof Snow=35.0) TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.64 0.49 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.03 (loc) 14 15 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 121 lb FT = 15% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF No.2 BOT CHORD 2x4 DF No.2 OTHERS 2x4 DF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 7-11-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-7-14 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 23-3-0. (lb) - Max Horz26=51(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 23, 24, 21, 19, 18, 17, 16 except 22=-114(LC 8), 25=-158(LC 1), 26=-159(LC 8), 14=-211(LC 19) Max Grav All reactions 250 lb or less at joint(s) 25, 17, 14 except 22=780(LC 1), 23=302(LC 19), 24=364(LC 19), 26=836(LC 19), 21=314(LC 20), 19=273(LC 20), 18=306(LC 20), 16=405(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-582/1015, 3-4=-561/1031, 4-5=-478/958, 5-6=-485/1008, 6-28=-451/941, 7-28=-446/1000, 7-8=-405/983, 8-9=-405/977, 9-29=-448/991, 10-29=-453/954, 10-11=-479/987, 11-12=-506/991, 12-13=-529/978, 13-14=-585/1035 BOT CHORD 2-30=-913/581, 27-30=-913/581, 26-27=-913/581, 25-26=-913/581, 24-25=-913/581, 23-24=-913/581, 22-23=-913/581, 21-22=-913/581, 20-21=-913/581, 19-20=-913/581, 18-19=-913/581, 17-18=-913/581, 16-17=-913/581, 14-16=-913/581 WEBS 8-22=-736/347, 7-23=-276/128, 6-24=-271/92, 4-26=-473/245, 9-21=-275/133, 11-18=-261/70, 13-16=-323/131 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=22ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Corner(3E) -1-4-0 to 1-8-0, Exterior(2N) 1-8-0 to 10-9-0, Corner(3R) 10-9-0 to 16-9-0, Exterior(2N) 16-9-0 to 25-10-0, Corner(3E) 25-10-0 to 28-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 35.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 24, 21, 19, 18, 17 , 16 except (jt=lb) 22=114, 25=158, 26=159, 14=211. 11) Non Standard bearing condition. Review required. 12) This truss is designed in accordance with the 2018 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.Continued on page 2 Job 232305 Truss A3E Truss Type GABLE Qty 2 Ply 1 Corcoran Apartments Job Reference (optional) 8.630 s Apr 20 2023 MiTek Industries, Inc. Fri Aug 18 17:04:31 2023 Page 2 Inteframe Components, LLC, Nampa, ID - 83687 ID:lGYcxQBaeSgZ3ivYMlikXMzMpNI-qz_wpE9B0Y2nU1620DVnW_9RLWWHp_4lqPgomFymXm_ LOAD CASE(S) Standard Job 232305 Truss A4E Truss Type GABLE Qty 1 Ply 1 Corcoran Apartments Job Reference (optional) 8.630 s Apr 20 2023 MiTek Industries, Inc. Fri Aug 18 17:04:33 2023 Page 1 Inteframe Components, LLC, Nampa, ID - 83687 ID:lGYcxQBaeSgZ3ivYMlikXMzMpNI-mM5hEwARY9JUjLFR7eXFbPFonJDhHwa2Hj9up8ymXly Scale = 1:47.2 T1 T1 B1 ST8ST7ST6ST5ST4ST3ST2ST1 ST8 ST7 ST6 ST5 ST4 ST3 ST2 B2 ST1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 38 39 40 41 42 3x6 3x4 5x6 3x4 4-3-0 4-3-0 27-6-0 23-3-0 -1-4-0 1-4-0 13-9-0 13-9-0 27-6-0 13-9-0 28-10-0 1-4-0 0- 6 - 1 5- 1 - 1 0- 6 - 1 4.00 12 Plate Offsets (X,Y)-- [11:0-3-0,Edge], [28:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=35.0) TCDL BCLL BCDL 35.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.51 0.43 0.19 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.03 (loc) 20 21 20 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 140 lb FT = 15% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF No.2 BOT CHORD 2x4 DF No.2 OTHERS 2x4 DF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 8-7-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 23-3-0. (lb) - Max Horz36=51(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 30, 31, 32, 33, 34, 29, 28, 27, 26, 25, 24, 23, 22 except 35=-360(LC 1), 36=-187(LC 8), 20=-167(LC 19) Max Grav All reactions 250 lb or less at joint(s) 31, 32, 33, 35, 28, 27, 26, 25, 24, 23, 20 except 30=513(LC 19), 34=307(LC 19), 36=840(LC 1), 29=488(LC 1), 22=392(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-507/900, 3-4=-486/886, 4-38=-402/761, 5-38=-400/798, 5-6=-429/869, 6-7=-403/856, 7-8=-387/858, 8-39=-366/824, 9-39=-364/856, 9-10=-345/877, 10-11=-276/754, 11-12=-275/748, 12-13=-347/872, 13-40=-364/843, 14-40=-366/821, 14-15=-389/851, 15-16=-405/850, 16-17=-423/850, 17-41=-439/854, 18-41=-442/833, 18-19=-452/829, 19-20=-506/903 BOT CHORD 2-42=-789/505, 37-42=-789/505, 36-37=-789/505, 35-36=-789/505, 34-35=-789/505, 33-34=-789/505, 32-33=-789/505, 31-32=-789/505, 30-31=-789/505, 29-30=-789/505, 28-29=-789/505, 27-28=-790/506, 26-27=-790/506, 25-26=-790/506, 24-25=-790/506, 23-24=-790/506, 22-23=-790/506, 20-22=-790/506 WEBS 10-30=-483/208, 4-36=-406/255, 12-29=-457/215, 19-22=-309/123 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=22ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Corner(3E) -1-4-0 to 1-8-0, Exterior(2N) 1-8-0 to 10-9-0, Corner(3R) 10-9-0 to 16-9-0, Exterior(2N) 16-9-0 to 25-10-0, Corner(3E) 25-10-0 to 28-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=35.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 1.00 times flat roof load of 35.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 30, 31, 32, 33, 34, 29 , 28, 27, 26, 25, 24, 23, 22 except (jt=lb) 35=360, 36=187, 20=167.Continued on page 2 Job 232305 Truss A4E Truss Type GABLE Qty 1 Ply 1 Corcoran Apartments Job Reference (optional) 8.630 s Apr 20 2023 MiTek Industries, Inc. Fri Aug 18 17:04:33 2023 Page 2 Inteframe Components, LLC, Nampa, ID - 83687 ID:lGYcxQBaeSgZ3ivYMlikXMzMpNI-mM5hEwARY9JUjLFR7eXFbPFonJDhHwa2Hj9up8ymXly NOTES- 11) Non Standard bearing condition. Review required. 12) This truss is designed in accordance with the 2018 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard