Loading...
HomeMy WebLinkAboutCORCORAN 6 UNIT-Reviewed-Corrections-Required (1)Author Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Corcoran 6 Unit - ApartmentsAddress : 358 S 3rd WApplication Type : Document Filename : CORCORAN 6 UNIT.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference AnnotationType Author : Department Status Page Review Comments Applicant Response Comments E-1 Callout Alex Owens : Electrical Open 6 Please provide available fault current calculation # 23-00358New Multi-Family Residence Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 08.21.2023 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) VICINITY MAP SCALE: N.T.S. SUBJECT PROPERTY WATERC / W C / W C / W 20' 25' 10' 10' 20' 20' 9' 37'-10" 20' 20'20'-3" 9'8' 5' S S S S S S (N) 6 UNIT MULTIFAMILY 4/1 5/2 6/3 11 33 2 6 5 44 5 6 S. 3RD WEST 115.50' 115.50' 82.50' 82.50' NO PARKING STORM WATER SERVICE 4" SANITARY SEWER HEATED FIRE RISER & ALARM PANEL ROOM TRASH ENCLOSURE (PERVIOUS PAVERS) SNOW STORAGE SNOW STORAGE (N) SOLID FENCE CONNECT ROOF DRAINS TO D.I. FIRE LANE "NO PARKING" SIGNAGE LANDING & SIDEWALK 2% MAX SLOPE AND CROSS SLOPE P/L P/L P/L P/L (E) GARAGE TO BE REMOVED (E) DWELLING TO BE REMOVED 1 A-1 1 A-1 6" CURB WHEEL STOP (N) STANDARD HYDRANT 60"60"60" 2 NO PARKING 5%5%2% 2%2% 2% MAX. 2%2% MAX. 6" STEP UP AT CURB FLUSH REVISIONS SHEET: SCALE: DATE: 11 8/15/2023 PROJECT DATA: A.P.N.RPR000P0103610 LOT SIZE .214 ACRES OCCUPANCY R2 CONSTRUCTION TYPE VB EXISTING RESIDENCE AREA 969 SF EXISTING GARAGE AREA 200 SF (N) 6 UNITS 3,480 SF UNIT 1 575 UNIT 2 501 UNIT 3 661 UNIT 4 575 UNIT 5 501 UNIT 6 661 SCOPE OF WORK: REMOVE (E) SINGLE DWELLING, CONSTRUCT NEW 6 UNIT APARTMENT BLDG. SHEET INDEX: A-1 SITE PLAN A-2 FLOOR PLANS A-3 EXTERIOR ELEVATIONS A-4 BUILDING SECTIONS S-001 GEN. STRUCTURAL NOTES S-101 FND PLAN S-102 2ND FLR FRAMING PLAN S-103 ROOF FRAMING PLAN S-501 FND DETAILS S-510 FLOOR FRAMING DETAILS S-520 ROOF FRAMING DETAILS S-601 SCHEDULES S-602 SCHEDULES E-1 ELECTRICAL PLANS SITE PLAN SCALE: 1" = 10' JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID A-1 REFERENCED CODES: 2018 INTERNATIONAL BUILDING CODE 2017 NATIONAL ELECTRICAL CODE 2018 MECHANICAL CODE OF IDAHO 2018 IDAHO COMMERCIAL ENERGY CODE 2018 IECC 2015 IDAHO PLUMBING CODE 2018 INTERNATIONAL FIRE CODE 2009 IDAHO ACCESSIBILITY CODE DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 SNOW STORAGE AREA PAVED PARKING AREA 4.455 SF SNOW STORAGE AREA, 493 SF DEFERRED ITEMS: 1. FIRE SPRINKLERS, NFPA 13R. SPRINKLERS MUST BE QUICK RESPONSE 2. ENVELOPE COMM CHECK 1. ACCESSIBLE PATH SCALE: 1" = 5' SB388 DW B1233L B1233L B18L B18L SB32 DWB24L B18RB18R SB32DW B24R SB388 DW B1233L B1233L B18L B18L SB32 DWB24L B18RB18R SB32DW B24R W3024W1842R W1842R W3042 W2842 W3042 W3024 W1842LW1842L W3042W2842W3042 W3042BCW3042LBCW2442L W2742L W3024 4040LS 4040LS 4040LS 6068 4040LS 4040LS 5040LS306830686040LS 3068 6040LS 4040LS 4040LS 41168 3068 3068 3068 3068 6068 3068 3068 31168 3068 3068 5068 31168 3660 3068 UP BB BB CC CC 2222 AA AA DD DD 1111 3333 22X24 UNDER FLOOR ACCESS DRYER VENT W/DAMPER DRYER VENT W/DAMPER MINI-SPLIT WALL UNITMINI-SPLIT WALL UNIT MINI-SPLIT WALL UNIT MINI-SPLITWALL UNIT MINI-SPLIT WALL UNIT MINI-SPLIT WALL UNIT MINI-SPLIT WALL UNIT MINI-SPLIT WALL UNIT 3'4'3'-1"4'-2"4'4'-5" 1'-6" 4' 3'-7" 2'-2" 4' 2'-5" 3'-9"6'1'-9"3'11"5"3'7"5'15'-8"12'-6"6'5'-9" 24'-3"6'-2"15'-5"24'-8" 4'-10" 4' 4'-7" 13'-5" 5'-6" 8'-7" 27'-6" 2'-11" 4' 1'-8" 8'-7" 5'-7" 9'-1" 8" 3' 7" 4'-3" 2'-4"4'2'-8" 12'-11"2'-9"9'2'-11"12'-7"6'-1"10'-1"2'-5"11'-9" 70'-6" 40" 40" 36" CL 24" 60" 48" 60"48" 60"48" CL 24"33" 2'2' 2'2' BEDROOM BATH LIVING KITCHEN BEDROOM BEDROOM CLOSET CLOSET BATH LIVING LIVING BEDROOM CLOSET CLOSET BEDROOM BATH KITCHEN KITCHEN 1 A-4 1 A-4 2 A-4 2 A-4 FIRE RISER CLOSET 22X24 UNDER FLOOR ACCESS 22X24 UNDER FLOOR ACCESS SPECSEAL LCC150 FIRE STOP COLLAR AT ABS/PVC DRAIN PIPE PENETRATION i/2" GYP. WALL BOARD UNDER MOISTURE BARRIER AND SIDING AT THIS WALL SEE A-5 FOR TYPE B REQ. SEE A-5 FOR TYPE B REQ. DRYER VENT W/DAMPER DN SB39 DW B9LB24L B18RB18R SB32DW B24R B18L B18L SB32 DWB24L SB352132 SB362132 SB302132 B30 B30 B12L SB39 DW B9LB24L B18RB18R SB32DW B24R B18L B18L SB32 DWB24L SB352132 SB362132 SB302132 B30 B30 B12L W3024W1842R W1842R W3042 W2842 W3042 W3024 W1842LW1842L W3042W2842W3042 W942LBCW2442L BCW3142 W3642 W3024 4040LS 4040LS 6040LS 6040LS306830686040LS 4040LS 4040LS 4040LS 4040LS 4040LS 2868 2668 2068 3068 2868 6068 28682868 2668 2668 6068 2668 3068 31168 5068 31168 BB BB CC CC 2222 AA AA DD DD 1111 3333 WH WH WH DRYER VENT W/DAMPER DRYER VENT W/DAMPER MINI-SPLIT WALL UNIT MINI-SPLIT WALL UNIT MINI-SPLITWALL UNIT MINI-SPLIT WALL UNIT MINI-SPLITWALL UNIT MINI-SPLIT WALL UNIT MINI-SPLIT WALL UNIT MINI-SPLITWALL UNIT 22X30 ATTIC ACCESS 22X30 ATTIC ACCESS 22X30 ATTIC ACCESS 5 1/2 X 12 BEAM 6X6 POST6X6 POST6X6 POST 6X6 POST6X6 POST 2'-2" 4' 2'-5" 2'-9"4'2'-10"4'-2"4'5'-5" 1'-10" 4' 3'-7" 12'-6"6'5'-9"9'-11"6'1'-9"3'11"5"3'21'-3" 24'-3"21'-7"24'-8" 2'-11" 4' 1'-4" 8'-3" 5'-7" 9'-5" 10" 3' 5" 4'-3" 2'-7"4'2'-8" 12'-8"2'-9"9'-3"2'-11"13'-7"5'-7"9'-7"2'-5"11'-9" 70'-6" 4'-10" 4' 4'-4" 13'-2" 5'-9" 8'-7" 27'-6" CLOSET CLOSET KITCHEN LIVING BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM LIVING LIVING BATH BATH BATH KITCHEN KITCHEN CLOSET FR DRYER VENT W/DAMPER ATTIC DRAFT STOP (SEE 4/A-2) i/2" GYP. WALL BOARD UNDER MOISTURE BARRIER AND SIDING AT THIS WALL SPECSEAL LCC150 FIRE STOP COLLAR AT ABS/PVC DRAIN PIPE PENETRATION 1 A-4 1 A-4 TYP. BALCONY BA-PFI-22-30 OR = 1 HR RATED SELF CLOSING AND LATCHING ATTIC ACCESS. TYP. 5/8 TYPE X GYP. BD. @ CEILING 1/2" GYP. BD. CONTINUOUS FROM DBL. PLT. OF UNIT SEPARATION WALLS TO UNDERSIDE OF ROOF SHEATHING. ATTACH w/ 1 1/4" TYPE W SCREWS 12" O.C. VERTICAL 2X MEMBER BY TRUSS MFG. ANNULAR SPACES FILLED WITH APPROVED FIRE SEALANT REVISIONS SHEET: SCALE: DATE: 11 8/15/2023 JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID A-2 1st FLOOR PLAN SCALE: 1/4" = 1' 2nd FLOOR PLAN SCALE: 1/4" = 1' DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 1-HR ASSEMBLIES 4. ATTIC DRAFT STOP 2211 33221133 22 1133 25' 17'-7" 22 1133 42" MIN. 34"-38" 4" SPHERE WILL NOT PASS TROUGH 6" SPHERE WILL NOT PASS TROUGH GRASPABLE RAILING, 1 1//4" - 2"ø OR 4" MIN. - MAX. 6 PERIMETER DIM. REVISIONS SHEET: SCALE: DATE: 11 8/15/2023 JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID A-3 DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 EXTERIOR ELEVATIONS SCALE: 1/4" = 1' APPROVED CORROSION-RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1.EXTERIOR DOOR AN WINDOW OPENINGS 2.AT THE INTERSECTION OF CHIMNEY OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS 3.UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS 4.CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIMS 5.WHERE EXTERIOR PORCHES,DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAMED CONSTRUCTION 6.AT ALL WALL AND ROOF INTERSECTIONS VINYL SIDING o/WSP COMPOSITION ROOF SHINGLES NORTH SOUTHEAST WEST STAIR NOTES: 1.GUARD RAIL HEIGHT MIN 42" 2.HAND RAIL TO BE CONTINUOUS AND TERMINATE AT WALL, POST OR TURNOUT W/ HEIGHT OF 34" - 38" ABOVE LINE OF STAIRS 3.LESS THAN 4" SPACE BETWEEN RAILING COMPONENTS, 6" ALLOWED BETWEEN TREAD/RISER INTERSECTION AND BOTTOM OF GUARD RAIL 4.GRASPABLE RAILING 1 1/4" - 2" DIAMETER 5.CLOSED RISER W/ 7" MAX. RISE 6.MIN. 11" TREAD DEPTH W/ MIN. 7.ALL WEATHER LANDING, FULL WIDTH OF STAIR, EXTEND 36" IN DIRECTION OF TRAVEL 8.HANDRAILS AND GUARDS SHALL BE DESIGNED TO RESIST A LINEAR LOAD OF 50 POUNDS PER LINEAR FOOT (1607.8.1) AND CONCENTRATED LOADS OF 200 POUNDS (167.8.1.1) 6 12 SELF-ADHERING POLYMER MODIFIED BITUMEN ICE BARRIER, EXTEND 24"INSIDE THE EXTERIOR WALL (TYP.) 22 22 11 11 33 33 22 22 11 11 33 33 I JOIST SUBFLOOR 5/8 TYPE X GWB 5/8 TYPE X GWB 2X6 PLT PSL RIM BD RESILIENT CHANNEL1/2" GWB 24" MIN. 5/8 TYPE X GYP. BD. BEHIND INTERSECTING WALL AT RATED WALLS LISTED 1 HR WALL ELEC. BOX LISTED 1 HR FIRE- STOP COLLAR NON METALLIC DWV PIPING DOMESTIC WATER PIPING COPPER PIPE FILL ANNULAR SPACE w/INTUMESCENT FIRE CAULKING TYP. 1 HR WALL GA WP 3371 LISTED 1 HR CEILING ELEC. BOX 6 : 12 6 : 12 WH WH WH DRYER VENTW/DAMPER DRYER VENT W/DAMPER MINI-SPLITWALL UNIT MINI-SPLITWALL UNIT MINI-SPLIT WALL UNIT MINI-SPLITWALL UNIT MINI-SPLITWALL UNIT MINI-SPLITWALL UNIT MINI-SPLITWALL UNIT MINI-SPLITWALL UNIT 22X30 ATTIC ACCESS 22X30 ATTIC ACCESS 22X30 ATTIC ACCESS ATTIC AREA A 670SF ATTIC AREA B 598SFATTIC AREA C 674SF V V V V V V V V V V V V V V V V V V REVISIONS SHEET: SCALE: DATE: 11 8/15/2023 JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID A-4 DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 SECTION 2 SCALE: 1/4" = 1' SECTION 1 SCALE: 1/4" = 1' 1. RATED WALL PENETRATION DETAILS SCALE: 1" = 1' 2. CEILING PENETRATION DETAIL SCALE: 1" = 1' 3. FLOOR/CEILING DETAIL SCALE: 1" = 1' ATTIC VENTILATION SCALE: 3/16" = 1' TABULATION ATTIC AREA A 670 SF TOTAL VENTILATION 670/150 = 4.47SF PROVIDE: (4) 100 SQIN EYEBROW VENTS 2.78SF (6) 3.5"X22.5" EAVE VENTS 2.24SF ATTIC AREA B 598 SF TOTAL VENTILATION 598/150 = 3.99SF PROVIDE: (3) 100 SQIN EYEBROW VENTS 2.08SF (6) 3.5"X22.5" EAVE VENTS 2.24SF ATTIC AREA C 674 SF TOTAL VENTILATION 674/150 = 4.49SF PROVIDE: (4) 100 SQIN EYEBROW VENTS 2.78SF (6) 3.5"X22.5" EAVE VENTS 2.24SF ALL VENTS TO BE COVERED WITH 1/4" METALLIC SCREENING REVISIONS SHEET: SCALE: DATE: 11 8/15/2023 JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID A-5 DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 R CO SD DM VS 120V RECEPTACLE LIGHT SWITCH VACANCY SENSOR DIMMER RECESSED LED ICAT FIXTURE SURFACE MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE FAN W/ HUMIDISTAT CONTROL FAN-LIGHT W/ HUMIDISTAT CONTROL SMOKE ALARM 110v w/BATTERY BACKUP C0 ALARM 110v w/BATTERY BACKUP SURFACE MOUNTED LED "SHOP" LIGHT CEILING FAN UP UNDER FLOOR WH UNDER FLOOR WH UNDER FLOOR WH 22X24 UNDER FLOOR ACCESS DRYER VENT W/DAMPER DRYER VENTW/DAMPER MINI-SPLITWALL UNITMINI-SPLITWALL UNIT MINI-SPLITWALL UNIT MINI-SPLIT WALL UNIT MINI-SPLITWALL UNIT MINI-SPLIT WALL UNIT MINI-SPLIT WALL UNIT MINI-SPLIT WALL UNIT R R GFCI GFCI GFCIGFCIGFCI GFCI GFCI GFCI GFCIGFCI GFCI GFCI GFCI GFCI GFCI GFCIGFCI GFCI GFCI SD SD SD SD SD SD SD SD 3 3 3 3 3 3 EP EP EP BEDROOM BATH LIVING KITCHEN BEDROOM BEDROOM CLOSET CLOSET BATH LIVING LIVING BEDROOM CLOSET CLOSET BEDROOM BATH KITCHEN KITCHEN FIRE RISER (6) 100 AMP METER ELEC MAIN FIRE ALARM PANEL HOUSE PANEL CLOSET ELECTRIC HEATER 100 AMP SUB-PANEL 100 AMP SUB-PANEL 100 AMP SUB-PANEL DN WH WH WH WH WH WH DRYER VENT W/DAMPER DRYER VENT W/DAMPER MINI-SPLITWALL UNIT MINI-SPLITWALL UNIT MINI-SPLIT WALL UNIT MINI-SPLITWALL UNIT MINI-SPLIT WALL UNIT MINI-SPLIT WALL UNIT MINI-SPLITWALL UNIT MINI-SPLIT WALL UNIT 22X30 ATTIC ACCESS 22X30 ATTIC ACCESS 22X30 ATTIC ACCESS 3 3 3 3 3 SD SD SD SD SD SD SD SD GFCI GFCIGFCIGFCI GFCIGFCIGFCI GFCI GFCI GFCIGFCI GFCIGFCIGFCI GFCI GFCI GFCI GFCI GFCI R R R R R EP EP EP 3 CLOSET CLOSET KITCHEN LIVING BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM LIVING LIVING BATH BATH BATH KITCHEN KITCHEN CLOSET FR BALCONY 100 AMP SUB-PANEL 100 AMP SUB-PANEL 100 AMP SUB-PANEL REVISIONS SHEET: SCALE: DATE: 11 8/15/2023 1ST FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1' Electrical notesElectrical notes a.A grounding electrode shall be provided per [NEC Article 250-50]. b.Provide two or more 20-amp small-appliance circuits to serve all countertop, wall and floor receptacles in the kitchen, pantry, breakfast room, dining room, or similar areas. Receptacle outlets shall be installed at each wall, island and peninsular counter space in kitchens and dining rooms per the requirements found in [NEC Article 210.52 (B) and (C)]. Such circuits shall have no other outlets. c.At least one 20-ampere branch circuit shall be dedicated to supply bathroom receptacles. At least one receptacle is required within 3-ft of each basin. [NEC Articles 210.11(C)(3)] [NEC 210.52(D)]   d.Where the 20-ampere circuit supplies a single bathroom, outlets for other equipment within the same bathroom shall be permitted to be supplied in accordance with [NEC Article 210.23(A)(1) and (A)(2)]. e.At least one additional 20-ampere branch circuit shall be dedicated to supply laundry receptacle outlet(s) required by [NEC Articles 210-11(C)(2) & 210-52(F)]. This circuit shall have no other outlets. f.Receptacle outlets shall be installed so that no point along the floor line in any wall space is more than 6-ft measured horizontally from an outlet in that space. Receptacle outlets are required in walls 2-ft or greater. Hallways of 10-ft or more in length shall have at least one receptacle outlet. [NEC Art. 210.52(A) and (H)] g.Tamper-Resistant Receptacles in Dwelling Units. In all areas specified in 210.52, all 125 volt, 15 and 20 ampere receptacles shall be listed as tamper-resistant receptacles. [NEC 406.12] h.Light fixtures that weight more than 6lbs or exceed 16-in in any dimension shall not be supported by the screw shell of a lamp holder. [NEC Art. 410.30(A)] i.Outlet boxes or outlet box systems used as the sole support of a ceiling-suspended (paddle) fan shall be listed and marked by the manufacturer as suitable for this purpose. The required marking shall include the maximum weight to be supported for ceiling fans that weigh more than 35-lbs. [NEC Art. 314.27(D), 422.18] j.An accessible 125-volt, single phase, 15 or 20 amp rated receptacle outlet shall be installed on the same level and within 25-ft of heating and air conditioning equipment. This service receptacle shall not be connected to the load side of the equipment disconnecting means. [NEC Art. 210.63] k.Receptacles within bathtub or shower space are prohibited, even if enclosed. [NEC Art. 406.9(C)] l.Cord-connected lighting fixtures, lighting tracks or ceiling-suspended (paddle) fans within 3-ft of horizontal edge and 8-ft vertical above top of tub/shower dam are prohibited. [NEC Art. 410.10(D)] JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID E-1 DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 2ND FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1' Please provide available fault current calculation REVISIONS SHEET: SCALE: DATE: 11 8/15/2023 BRACE WALL PLAN SCALE: 1/4" = 1' JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID L = XX" 11 LENGTH OF BRACE WALL PANEL BRACE WALL KEY MIN. 3/8 STRUCTURAL WOOD PANEL NAILED W/ 8d 6"O.C. EDGE 12" O.C. FIELD SILL NAILED W/ 16d 2-12" O.C. ALTERNATE BRACE WALL MIN. 2'8"x3/8 STRUCTURAL WOOD PANEL NAILED W/ 8d 6"O.C. EDGE 12" O.C. FIELD SILL NAILED W/ 16d 2-12" O.C. 1800 # HOLD DOWN ON DOUBLE STUDS AT EACH END OF PANEL A1A1 PFPF CONTINUOUSLY SHEATHED PORTAL FRAME, SEE 5/8, 6/8 CSCS CONTINUOUS SHEATHED BRACE WALL MIN. 3/8 STRUCTURAL WOOD PANEL NAILED W/ 8d 6"O.C. EDGE 12" O.C. FIELD ON ALL SHEATHABLE SURFACES (SEE CRC 602.10.5 & 602.10.7) END CONDITION (SEE CRC 602.10.7)44 800# HOLD DOWN DEVICE A-5 DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370 REVISIONS SHEET: SCALE: DATE: 11 8/15/2023 2ND FLOOR ELECTRICAL PLAN SCALE: 1/4" = 1' JOB NUMBER CORCORAN 6 UNIT 358 S. 3RD WEST REXBURG ID E-2 DRAWN BY: DAREN WARDELL 19802 VIA REDONDA RD. SONORA CA 95370