Loading...
HomeMy WebLinkAboutREDLINED ELEVATION PLANS - 22-00244 - 3954 Jake Way Suites 101 & 102 - Storage BuildingAuthor Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : 3954 Jake Way Suites 101 & 102 - Storage Building Address : 3954 Jake Way Suites 101 & 102 Application Type : Document Filename : Fred Baugh 4-11-22.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Free text Cody Jones : Building Open 1 Sprinkler system not needed for an S1 as long as future tenants meet compliance of section 903.2.9. Pg 1 Free text Cody Jones : Building Open 1 Type IIB construction is non combustible material. Pg 1 Free text Cody Jones : Building Open 1 Sidewalk cross slope not to exceed 2%. Sidewalk to meet ADA requirements. At least on parking spot needs to be van accessible with a total of 13 parking stalls. Pg 3 Free text Stan Crittenden : Fire Open 3 International Fire Code section 507 & Appendix B require water supply for fire fighting efforts. 250 gpm for 2 hours is required. Please see the Fire Flow document for more information. Pg 3 Free text Stan Crittenden : Fire Open 3 International Fire Code 503.2.5 requires any dead end access road over 150 ft. shall be provided with appropriate size turn around, see IFC appendix D. # 22-00244 Madison County - Commercial Report Date: 04.19.2022 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 3 Free text Stan Crittenden : Fire Open 3 International Fire Code section 503.1.1 requires that the fire department access road extend to with in 150ft. of all portions of the building. Report Date: 04.19.2022 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) 14'x14' OHD 14'x14' OHD 14'x14' OHDX-BRACE X-BRACE X -BR A C E X -BR A C E 14'x14' OHD X-BRACE X-BRACE 60 ' - 0 " 5' - 0 " 20 ' - 0 " 60' x 100' space #160' x 100' space #2 Office Office Fu l l H e i g h t P a r t i t i o n w a l l -Bathrooms to meet ADA Standards Bathrooms to meet ADA Standards -Exit Lighting and Exit Signs will comply with section 1008 and 1013 -Doors Meet Section 1010 -Glass will meet section 24 of the 2018 I.B.C. -Special Inspections provided by Connect engineering -Occupancy Classification S-1 -Construction type IIB Building being built for future tennants. Our vision is for a small business owner to have a space for their business. Sprinkler system not needed for an S1 as long as future tenants meet compliance of section 903.2.9. Type IIB construction is non combustible material. Sidewalk cross slope not to exceed 2%. Sidewalk to meet ADA requirements. At least on parking spot needs to be van accessible with a total of 13 parking stalls. Re v . 4/ 1 1 / 2 0 2 2 4: 1 8 : 2 8 P M CO V E R Au t h o r FR E D B A U G H TH O R N T O N A1 0 1 FRED BAUGH 60'x200'x18' THORNTON SHOP 14'x14' OHD X-BRACE X-BRACE X -BR A C E X -BR A C E X-BRACE X-BRACE 45' - 0" 300' - 0" 10 ' - 0 " 60 ' - 0 " 5' - 0 " 20 ' - 0 " 46 ' - 6 " Storm Water Pond Septic Replacement Drainfield 14 1 ' - 6 " 1/2% Slope 1% 60' x 100' space #160' x 100' space #2 106' - 0"Neighboring well 300' from pond line Well Location 5' - 0" Ja k e W a y Ja k e W a y Office Area Bath 16' - 2" Parking Lot 24 ' - 0 " En t r a n c e 14'x14' OHD Re v . 1 4/ 1 1 / 2 0 2 2 4: 1 8 : 2 9 P M FL O O R P L A N Au t h o r FR E D B A U G H TH O R N T O N A1 0 2 1" = 30'-0"1 100 North International Fire Code section 507 & Appendix B require water supply for fire fighting efforts. 250 gpm for 2 hours is required. Please see the Fire Flow document for more information. International Fire Code 503.2.5 requires any dead end access road over 150 ft. shall be provided with appropriate size turn around, see IFC appendix D. International Fire Code section 503.1.1 requires that the fire department access road extend to with in 150ft. of all portions of the building. 100 0' -0" 118 18' -0" 102 2' -0" A B C D 100 0' -0" 118 18' -0" 102 2' -0" ABCD 23' - 0" 1" / 1'-0" Re v . 4/ 1 1 / 2 0 2 2 4: 1 8 : 2 9 P M EL E V A T I O N Au t h o r FR E D B A U G H TH O R N T O N A1 0 3 1/8" = 1'-0"2 West 1/8" = 1'-0"1 East 100 0' -0" 118 18' -0" 102 2' -0" 5 4 3 2 16789 100 0' -0" 118 18' -0" 102 2' -0" 54321 6 7 8 9 Re v . 4/ 1 1 / 2 0 2 2 4: 1 8 : 3 0 P M EL E V A T I O N Au t h o r FR E D B A U G H TH O R N T O N A1 0 4 1/16" = 1'-0"1 North 1/16" = 1'-0"2 South