HomeMy WebLinkAboutAPPROVED PLANS - 21-00205 - 646 Willow Brook Cir - AdditionAuthor Name Author Email Author Phone No.:
Larry Beesley Larry.Beesley@rexburg.org 208-372-2176
Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164
Description : 646 Willow Brook Cir - Addition
Address : 646 Willow Brook Cir
Record Type : Single Family - Addition
Document Filename : 0528GarnerPermit.pdf
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Approved
# 21-00205
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
A-0 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector
A-1 Stamp Larry Beesley : Building Open 2 Approved - Building Inspector
A-1 Free text Larry Beesley : Building Open 2 SD
A-1 Free text Larry Beesley : Building Open 2 SD
A-1 Free text Larry Beesley : Building Open 2 SD CO
A-1 Free text Larry Beesley : Building Open 2 SD CO
A-1 Free text Larry Beesley : Building Open 2 Smoke detector needs 3' from bathroom door. and 10' from
kitchen range
A-1 Line Larry Beesley : Building Open 2
A-1 Rectangle Larry Beesley : Building Open 2
A-1 Free text Larry Beesley : Building Open 2 4' wall
A-1 Line Larry Beesley : Building Open 2
A-1 Line Larry Beesley : Building Open 2
A-1 Free text Larry Beesley : Building Open 2 20'
Single Family - Addition
This plan has been red lined for things that are required. Also a shier wall is needed in the garage to make the garage compliant with the code. A footing can be poured with the
floor and the wall must be sheeted with OSB for the shier strength that is needed.
Approval of plans does not constitute approval of variance from code
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
A-1 Free text Larry Beesley : Building Open 2 4' shier wall with footings poured in with the floor
A-1 Line Larry Beesley : Building Open 2
A-1 Free text Larry Beesley : Building Open 2 Attic Access 22"x30" minimum access where attic clear height
exceeds 30" (R807)
A-1 Free text Larry Beesley : Building Open 2 2018 IRC Code
A-2 Stamp Larry Beesley : Building Open 3 Approved - Building Inspector
A-2 Free text Larry Beesley : Building Open 3 X
A-2 Free text Larry Beesley : Building Open 3 X
A-2 Free text Larry Beesley : Building Open 3 X
A-2 Free text Larry Beesley : Building Open 3 X
A-2 Free text Larry Beesley : Building Open 3 X
A-2 Free text Larry Beesley : Building Open 3 X
A-2 Free text Larry Beesley : Building Open 3 X
A-2 Free text Larry Beesley : Building Open 3 X
A-2 Free text Larry Beesley : Building Open 3 X
A-2 Free text Larry Beesley : Building Open 3 X
A-2 Free text Larry Beesley : Building Open 3 4200 LB HOLD DOWNS
A-2 Line Larry Beesley : Building Open 3
A-2 Line Larry Beesley : Building Open 3
A-2 Line Larry Beesley : Building Open 3
A-2 Line Larry Beesley : Building Open 3
A-2 Free text Larry Beesley : Building Open 3 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12"
Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6"
A-2 Free text Larry Beesley : Building Open 3 Footings min. 16"x 8" foundation 8" x 4' ?
A-3 Stamp Larry Beesley : Building Open 4 Approved - Building Inspector
A-3 Free text Larry Beesley : Building Open 4 Roof Trusses (designed according to R802.10.1) 35 # Snow and
90 mph winds (Local Conditions)
A-3 Free text Larry Beesley : Building Open 4 Required
A-4 Stamp Larry Beesley : Building Open 5 Approved - Building Inspector
A-4 Free text Larry Beesley : Building Open 5 Roof Ventilation as per R806
A-4 Free text Larry Beesley : Building Open 5 Ground Surface to Slope away from Foundation a minimum of
6" within first 10 ft.
A-4 Free text Larry Beesley : Building Open 5 Minimum Frost Depth Ground Surface to Bottom of Footing
36"
Approval of plans does not constitute approval of variance from code
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
A-5 Stamp Larry Beesley : Building Open 6 Approved - Building Inspector
A-5 Free text Larry Beesley : Building Open 6 Roof Ventilation as per R806
A-6 Stamp Larry Beesley : Building Open 7 Approved - Building Inspector
A-0 Stamp Kyle Baldwin : P&Z Open 1 Approved - Planning and Zoning
A-0 Line Kyle Baldwin : P&Z Open 1 30.21 ft
Approval of plans does not constitute approval of variance from code
±
1
6
5
'
±267'
WILLOWBROOK
EXISTING
RESIDENCE
MOTHER
IN-LAW
2110
05/04/21
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
64
6
W
i
l
l
o
w
b
r
o
o
k
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
Ga
r
n
e
r
M
o
t
h
e
r
-
i
n
-
l
a
w
DATE:
PROJECT:
REVISION
DATES:
R
E
S
I
D
E
N
C
E
05/28/21
A-0
SI
T
E
L
A
Y
O
U
T
646 Willowbrook, Rexburg, ID 83440
Garner Mother-in-Law
30
.
2
1
f
t
REF
M/W
D/W
13'5" x 13'2"
BED. #1
13'5" X 14'0"
LIVING
25'0" X 28'5"
2-CAR GARAGE
13'8" X 10'0"
STUDY
11'5" X 10'7"
BED. #2
11'10" X 12'4"
KITCHEN
1042 SF
ADDITION
COVERED CONCRETE WALKWAY
23'5" X 16'0"
3rd CAR GARAGE
WINDOW SCHEDULE
SYM.SIZE TYPE NOTESQTY
DOOR SCHEDULE
SYM.SIZE NOTESTYPEHARDWARE
2110
05/04/21
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
64
6
W
i
l
l
o
w
b
r
o
o
k
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
Ga
r
n
e
r
M
o
t
h
e
r
-
i
n
-
l
a
w
DATE:
PROJECT:
REVISION
DATES:
R
E
S
I
D
E
N
C
E
05/28/21
FL
O
O
R
P
L
A
N
A-1
SD
SD
SD CO
SD CO
Smoke detector needs 3' from
bathroom door. and 10' from
kitchen range
4' wall 20'
4' shier wall with footings
poured in with the floor
Attic Access 22"x30" minimum access
where attic clear height exceeds 30" (R807)
2018 IRC Code
GARAGE SLABCRAWL SPACE
2110
05/04/21
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
64
6
W
i
l
l
o
w
b
r
o
o
k
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
Ga
r
n
e
r
M
o
t
h
e
r
-
i
n
-
l
a
w
DATE:
PROJECT:
REVISION
DATES:
R
E
S
I
D
E
N
C
E
05/28/21
FO
U
N
D
A
T
I
O
N
A-2
X
X
X
X
X
X
X
X
X
X
4200 LB HOLD DOWNS
Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12"
Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6"
Footings min. 16"x 8"
foundation 8" x 4' ?
2110
05/04/21
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
64
6
W
i
l
l
o
w
b
r
o
o
k
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
Ga
r
n
e
r
M
o
t
h
e
r
-
i
n
-
l
a
w
DATE:
PROJECT:
REVISION
DATES:
R
E
S
I
D
E
N
C
E
05/28/21
RO
O
F
L
A
Y
O
U
T
A-3
GENERAL NOTES
Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions)
Required
NORTH ELEVATION
WEST ELEVATION
2110
05/04/21
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
64
6
W
i
l
l
o
w
b
r
o
o
k
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
Ga
r
n
e
r
M
o
t
h
e
r
-
i
n
-
l
a
w
DATE:
PROJECT:
REVISION
DATES:
R
E
S
I
D
E
N
C
E
05/28/21
A-4
EX
T
E
R
I
O
R
EL
E
V
A
T
I
O
N
S
Roof Ventilation as per R806
Ground Surface to Slope away from Foundation a minimum of
6" within first 10 ft.
Minimum Frost Depth Ground Surface to Bottom of Footing 36"
SOUTH ELEVATION
EAST ELEVATION
EXISTING HOUSE
2110
05/04/21
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
64
6
W
i
l
l
o
w
b
r
o
o
k
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
Ga
r
n
e
r
M
o
t
h
e
r
-
i
n
-
l
a
w
DATE:
PROJECT:
REVISION
DATES:
R
E
S
I
D
E
N
C
E
05/28/21
A-5
EX
T
E
R
I
O
R
EL
E
V
A
T
I
O
N
S
Roof Ventilation as per R806
REF
M/W
D/W
13'5" x 13'2"
BED. #1
13'5" X 14'0"
LIVING
25'0" X 28'5"
2-CAR GARAGE
13'8" X 10'0"
STUDY
11'5" X 10'7"
BED. #2
11'10" X 12'4"
KITCHEN
1042 SF
ADDITION
COVERED CONCRETE WALKWAY
23'5" X 16'0"
3rd CAR GARAGE
2110
05/04/21
DR
A
W
I
N
G
S
A
R
E
F
O
R
M
A
T
T
E
D
T
O
P
R
I
N
T
T
O
S
C
A
L
E
O
N
2
4
"
X
3
6
"
.
T
H
E
S
E
P
L
A
N
S
W
E
R
E
D
R
A
F
T
E
D
B
Y
V
R
D
E
S
I
G
N
.
P
L
E
A
S
E
C
O
N
T
A
C
T
(
2
0
8
)
2
0
6
-
9
6
8
1
F
O
R
D
E
S
I
G
N
S
E
R
V
I
C
E
S
.
G
E
N
E
R
A
L
C
O
N
T
R
A
C
T
O
R
I
S
R
E
S
P
O
N
S
I
B
L
E
T
O
V
E
R
I
F
Y
D
E
S
I
G
N
I
S
E
N
G
I
N
E
E
R
E
D
I
F
R
E
Q
U
I
R
E
D
A
N
D
I
S
C
O
N
S
T
R
U
C
T
E
D
T
O
C
U
R
R
E
N
T
C
O
D
E
R
E
Q
U
I
R
E
M
E
N
T
S
.
64
6
W
i
l
l
o
w
b
r
o
o
k
Re
x
b
u
r
g
,
I
D
8
3
4
4
0
Ga
r
n
e
r
M
o
t
h
e
r
-
i
n
-
l
a
w
DATE:
PROJECT:
REVISION
DATES:
R
E
S
I
D
E
N
C
E
05/28/21
FI
N
I
S
H
E
S
A-6