Loading...
HomeMy WebLinkAboutFS - 23-204 FP3 - 22-00795 - Madison Station Apartments(ATTIC DRAFT STOP) —\ NON COMBUSTIBLE NO SPRINKLER Pf 2 LAYERS 5/8" TYPE Y GYP Fl\ I" CPVC BRANCH LINE ' it EXTERIOR WALL BATT INSULATION. r-21 1RE5IDENAL R3516 4.9k 115° SEMI RECESS 66F ITYPJ — — 's IIIII 11II �JI R5134 5.6k 200° 11 DRY NSW ITYPJ I " CPVC BRANCH LINE(TYP) a o FOIL SCRIM KRAFT (FSK) BATT INSULATION ABOVE SU CY2. CEILING SYSTEMS IN ATTIC SPACE. r-50 / ABOVE CEILING 'ION REQUIRED CEILING (1 HOUR RATED) � • s RESIDENAL R3516 4.11115* SEMI RECESS SSP (TYPJ DRAFT STOP) NON COMUSTIBLEABOVE NO SPRINKLER PROTECTION REQUIRED BID. • I gal- .................. ' :: — -09 iRA1664 5bk 200° _ DH 56 DRY EC NSW 1 " CPVC BRANCH LINE(TYP.) ��� ss rsrrss WALKWAYS ARE OF NON COMBUSTIBLE ATERI/ AV Ik NO SPRINKLER PROTECTION REQUIRED (TYPJ �' CPVC BRANCH LINE(TYP.) C II CEILINGS A7 9'-O" ABOVE FINISHED FLOOR FIRE SPRINKLER PIPE AT 9'-6" ABOVE FINISHED FLOOR < 7[D Ej] �Cf I iRESIDENAL R3516 4.9k 116" SEMI RECESS 55P (TYP) iR5134 5bk 200° DRY NSW (TYP.) �20'-6ll elev F.F. 3RD FLOOR I mr iRESIDENAL R3516 4.9k 115' EXTERIOR WALL BATT SEMI RECESS 55P (TYP.) INSULATION. r-21 OIL 10'-3., F.F. 2ND FLOOR I" CPVC BRANCH LINE(TYP.) o a F.F. 1ST FLOOR —4'-0" elev T.O.FOOTING INSULATION -TENT OVER PIPE WITH BATT INSULATION TO AVOID FILLING IN BETWEEN PIPE AND CEILING. COLD AREA STRUCTUR SPRINKLER PIPING TO STAY 64TT INSULATION MIN R38 AS CLOSE TO TRUSS HEATED AREA BOTTOM CHORDS AS POSSIBLE TENT INSULATION DETAIL SCALE: NTS I CPVC DOUBLE R45TENER STRAP TYPE HANGER NOT TO SCALE HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE 0 0 I CPVC OFFSET NO BLOCK TYPE HANGER NOT TO SCALE LISTED RESTRAINT FOR 3/4" TO 2" CPVC FOR VERTICAL OR HORIZONTAL INSTALLATION 0 0 I CFvG DOUBLE FASTENER STRAP TYPE HANGER NOT TO SCALE HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE ** HANGER TICKS AND EARTHQUAKE BRACING SYMBOLS ARE SHOWN AS GRAPHIC REPRESENTAION ONLY. ACTUAL LOCATIONS MAY VARY PER FIELD CONDITIONS. ALL HANGERS AND EARTHQUAKE BRACING IN ACCORDANCE WITH NFPA 13 11.4.2, TABLE 11.4.2.1 FOR HANGERS AND NFPA 13 18.5 AND HYDRAULIC CALULATIONS FOR EARTHQUAKE BRACING FULLY -REACTED, FINISHED SPRAY POLYURETHANE FOAM (SPF) IS COMPATIBLE WITH CPVC AND FIRE-PEX SYSTEMS. CURRENT AND PROPER INSTALLATION PRACTICES MUST BE ADHERED TO IN ORDER TO ENSURE THERE IS NO COMPROMISE TO THE CPVC/FIRE-PEX SYSTEM DURING THE APPLICATION OF SPF. PHOENIX FIRE WILL NOT BE RESPONSIBLE FOR ANY SYSTEM DAMAGED, COMPROMISED OR AFFECTED BY IMPROPER INSTALLATION TECHNIQUES, INSTALLATION EQUIPMENT MALFUNCTIONS, OR SPF CONTRACTOR NEGLIGENCE. I-IANGZR SP,4C/NG CHART TABLE 4-5.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (FT -IN.) NOMINAL PIPE SIZE (IN) 34 1 11 4 11 2 2 21 2 3 4 6 STEEL PIPE N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 THREADEAA D LIGCPVC N/A 12-0 12-0 12-0 12-0 12-0 12-0 N/A N/A 5-6 6-0 6-6 7-0 8-0 9-0 10-0 N/A N/A PEX 2-8 2-8 4-0 4-0 4-0 N/A N/A N/A N/A FOR STEEL PIPE, THE MAXIMUM LENGTH FOR UNSUPPORTED ARMOVER SHALL BE 2'0"(CPVC 1'0"). WHEN PRESSURE EXCEEDS 100 PSI, UNSUPPORTED LENGTH SHALL BE 1'0"(CPVC 0'9"). FIGURE A-4-5.2.3.3 DISTANCE FROM SPRINKLER TO HANGER 36" FOR 1" 48" 60" FOR 11/4" MAX. FOR 11 /2" OR LARGE THEN EXTEND HERE \ GREATER THAN 36" FOR 1" GREATER THAN 48:: FOR GREATER THAN 60 FOR 11�2" OR LARGE;!�� TABLE 2-6.4.1 HANGER ROD SIZE PIPE SIZE DIAM. OF ROD PIPE SIZE DIAM. OF ROD UP TO AND 3/8" 6 AND 8 1/2" INCLUDING 4" NOTE: TYPICAL HANGER TICK MARKS AS SHOWN ON PIPING PLAN MAY NOT REFLECT ACTUAL FIELD INSTALLATION. FINAL H,4NGER INSTALLATION SHALL BE IN ACCORDANCE UJITH THE REQUIREMENTS OF NFP,4 13 11.2.2 TABLE 1-1.4.2.1(a) AS PER NFPA 13R TABLE 6.2.3.3.3 MINIMUM DISTANCE FOR SPRINKLERS ARE AS FOLLOWS: FROM EDGE OF FROM EDGE OF SOURCE TO SOURCE TO HEAT SOURCE ORDINARY TEMP. INTERMEDIATE SPRINKLER TEMP. SPRINKLER * SIDE OF FIREPLACE -------------------- 36" -------------------- 12'1 * FRONT OF FIREPLACE -------------------- 6011 -------------------- 3611 , COAL OR WOOD BURNING STOVE---------- 42" -------------------- 12" * KITCHEN RANGE, WALL OVEN HOT AIR FLUES, UNIINSULATED ------------ 18" -------------------- 911 HEAT DUCTS * UNINSULATED HOT WATER PIPES --------- 12" -------------------- loll , SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS ------------ 2411 --------------------12'1 * FRONT OF WALL MOUNTED HOT AIR DIFFUSERS ----------------------- 36" --------------------IS" * HOT WATER HEATER OR FURNACE --------- loll -------------------- 3" * LIGHT FIXTURE OW-25OW------------------ loll -------------------- 311 * LIGHT FIXTURE 250111-499W--------------- 12" -------------------- loll * SPRINKLERS ARE NOT REQUIRED IN BATHROOMS NOT EXCEEDING 55 S.F. * SPRINKLERS ARE NOT REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES WHERE THE SPACE DOES NOT EXCEED 24 S.F. AND THE WALLS AND CEILINGS ARE OF NON-COMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS. * SPRINKLERS ARE NOT REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND OTHER SIMILAR STRUCTURES. * SPRINKLERS ARE NOT REQUIRED IN ATTICS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT INTENDED FOR LIVING PURPOSES OR STORAGE. * SPRINKLERS ARE NOT REQUIRED IN ENTRANCE FOYERS THAT ARE NOT THE ONLY MEANS OF EGRESS. 4130 AIRPORT ROAD NAMPA, IDAHO 83687 PHONE: (208)468-9115 FAX: (208) 461-9117 ID. LIC. F.P. S. C. # 108 ID.PUDLIC WORKS LIC. #16630-A-4(13930) UTAH LIC. ## 6579958-5501 S370 OREGON LIC. ## 181692 WYOMING ID ## 2008-000553828 WASHINGTON LIC. ## PHOENFP911 KL JOB INFO FR1IATION 23-204 MADISON STATION APT. BLDG. #1 511 TREJO REXBURG, ID 03440 RAWN BY - TERI CRUICKSHAI CHECKED BY : TRENT RICE NICET # 101524 DATE . JULY, 2023 CODES: NFPA 13R, 2019 IFC 2010 OCCUPANCY CLASS : R-2 CONSTRUCTION TYPE: V B SQUARE FOOTAGE : 36,019 NUMBER OF FLOORS : 3 PLAN SCALE : AS NOTED ON PLANS NOTICE IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE HEAT ADEQUATE TO PREVENT FREEZING THROUGHOUT AREAS PROTECTED BY WET PIPE FIRE SPRINKLER SYSTEMS INCLUDING ALL ENCLOSURES FOR DRY PIPE VALVES, DELUGE VALVES, AND ALL OTHER VALVES CONTROLLING WATER SUPPLIES TO THE FIRE SPRINKLER SYSTEMS. CONTRACT WITH: NORTHERN STATES DEVELOPMENT PO BOX 142 MENAN, ID 03434 PHONE NUMBER: P:20a-154-9389 EX:IOI NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES The records of this organization show that TRENT 510E Automatic Sprinkler System Layout 00301 / LEVEL III is certified in the technical area(s) Technician Certification No. 101524 Certification(s) Valid Thru 04/01/2024 NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES The records of this organization show that DON WELAND Automatic Sprinkler System Layout LEVEL II is certified in the technical area(s) Technician Certification No. 105253 Certification(s) Valid Thru OO/01/2026 NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES The records of this organization show that 505TON ORAHOOD Automatic Sprinkler System Layout LEVEL I is certified in the technical area(s) Technician Certification No. 156541 Certification(s) Valid ThmO3/01/2025 NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES The records of this organization show that Automatic Sprinkler System Layout is certified in the technical area(s) Technician Certification No. Certification(s) Valid Thru 9 0 .s m o: Ils 5HEET 3 OF 3