HomeMy WebLinkAboutFS - 23-204 FP2 - 22-00795 - Madison Station ApartmentsWD WDWDW DWD WDWD WDWDW DWD
WD016027019014WD
WDWDW D
WDWDWD WDWDW DWD
WDS101S102S201S202001004005002003006WD
WDWDWDW D WDWD WDWDWDW D
WDF1F2493047028055054052051061060056This system as shown oncompany print nodatedforatcontract nois designed to discharge at a rate ofa maximum area ofwhen supplied with water at a rate ofOccupancy classification:Commodity classification:Maximum storage height:Storage arrangement:Number of heads flowing:System Type:Maximum velocity:Flow from In-Rack sprinklers:Flow from Overhead sprinklers:Flow from Inside Hoses:Flow from Outside Hoses:Other fixed flows:Total flow in system piping:Additional flow at/beyond source:Total of all flows:Calculation results for Design Areagpm/ft² (L/min/m²) of floor area over-Surplus Pressure at Source:Pressure Required at Source:Pressure Available at Source:atat the base of the riser.Hose stream allowance ofis included in the above.13RD FLOORPHOENIX FIRE PROTECTION07/2023MADISON STATION APT. BLDG 1577 TREJO ST.23-2040.05760 ft²38.1 gpm51.3 psiLIGHT2Wet8 ft/s0 gpm38.1 gpm0 gpm0 gpm0 gpm38.1 gpm100 gpm138.1 gpm51.3 psi60 psi8.6 psiDesign Area Density:Calculations usingMethodOccupancy Classification:Design AreaSystemAdditional Outside Hose:Design Area Size:Notes:1Wet3RD FLOORDemandHazen-WilliamsLIGHT0.05100PER NFPA 13R, 2019 7.1.1.3.1Design Area Density:Calculations usingMethodOccupancy Classification:Design AreaSystemAdditional Outside Hose:Design Area Size:Notes:2Wet3RD FLOORDemandHazen-WilliamsLIGHT0.05100PER NFPA 13R, 2019 7.1.1.3.1This system as shown oncompany print nodatedforatcontract nois designed to discharge at a rate ofa maximum area ofwhen supplied with water at a rate ofOccupancy classification:Commodity classification:Maximum storage height:Storage arrangement:Number of heads flowing:System Type:Maximum velocity:Flow from In-Rack sprinklers:Flow from Overhead sprinklers:Flow from Inside Hoses:Flow from Outside Hoses:Other fixed flows:Total flow in system piping:Additional flow at/beyond source:Total of all flows:Calculation results for Design Areagpm/ft² (L/min/m²) of floor area over-Surplus Pressure at Source:Pressure Required at Source:Pressure Available at Source:atat the base of the riser.Hose stream allowance ofis included in the above.23RD FLOORPHOENIX FIRE PROTECTION07/2023MADISON STATION APT. BLDG 1577 TREJO ST.23-2040.05760 ft²38.1 gpm54.1 psiLIGHT2Wet8 ft/s0 gpm38.1 gpm0 gpm0 gpm0 gpm38.1 gpm100 gpm138.1 gpm54.1 psi60 psi5.9 psi