Loading...
HomeMy WebLinkAboutSITE PLAN Rev 1 8.7.23 - 23-00358 - Corcoran 6 Unit Apartments-Reviewed-Corrections-Required (1)Author Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Joel Gray Joel.Gray@rexburg.org 208-372-2331 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Katie Saurey Katie.Saurey@rexburg.org 208-372-2167 Description : Corcoran 6 Unit - Apartments Address : 358 S 3rd W Application Type : Document Filename : SITE PLAN Rev 1 8.7.23 - 23-00358 - Corcoran 6 Unit Apartments.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A-1 Callout Stan Crittenden : Fire Open 1 IFC 503.2.1 Requires that the Access road be a minimum width of 20 ft. A-1 Free Text Stan Crittenden : Fire Open 1 IFC 2018 503.1.1 requires that a fire hydrant be located with-in 150 ft. of the Fire Department connection. A-1 Callout Kyle Baldwin : P&Z Open 1 20' access minimum A-1 Free Text Kyle Baldwin : P&Z Open 1 Landscape Plan needed to assess screening and sight triangle requirements A-1 Free Text Joel Gray : PW Open 1 Storm drainage calculations required. A-1 Free Text Joel Gray : PW Open 1 What size of trash receptacle will be used? A-1 Free Text Joel Gray : PW Open 1 24 ft maneuvering area required for 90 degree parking. # 23-00358 New Multi-Family Residence Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 08.15.2023 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) VICINITY MAP SCALE: N.T.S. SUBJECT PROPERTY WA T E R C / W C / W C / W 20' 25' 1 0 ' 1 0 ' 1 9 ' 20' 9 ' 37'-10" 2 0 ' 20'20'-3" 9'8' 6 ' S S S S S S (N) 6 UNIT MULTIFAMILY 4/1 5/2 6/3 11 33 2 6 5 44 5 6 S. 3 R D W E S T 115.50' 115.50' 82 . 5 0 ' 82 . 5 0 ' NO PARKING STORM WATER SERVICE 4" SANITARY SEWER HEATED FIRE RISER & ALARM PANEL ROOM TRASH ENCLOSURE (PERVIOUS PAVERS) SNOW STORAGE SNOW STORAGE (N) SOLID FENCE CONNECT ROOF DRAINS TO D.I. FIRE LANE "NO PARKING" SIGNAGE LANDING & SIDEWALK 2% MAX SLOPE AND CROSS SLOPE P/L P/L P/ L P/ L (E) GARAGE TO BE REMOVED (E) DWELLING TO BE REMOVED 1 A-1 1 A-1 6" CURB 60"60"60" 2 NO PARKING 5%5%2% 2%2% 2% MAX. 2%2% MAX. 6" STEP UP AT CURB FLUSH REVISIONS SHEET: SCALE: DATE: 11 8/5/2023 PROJECT DATA: A.P.N.RPR000P0103610 LOT SIZE .214 ACRES OCCUPANCY R2 CONSTRUCTION TYPE VB EXISTING RESIDENCE AREA 969 SF EXISTING GARAGE AREA 200 SF (N) 6 UNITS 3,480 SF UNIT 1 575 UNIT 2 501 UNIT 3 661 UNIT 4 575 UNIT 5 501 UNIT 6 661 SCOPE OF WORK: REMOVE (E) SINGLE DWELLING, CONSTRUCT NEW 6 UNIT APARTMENT BLDG. SHEET INDEX: A-1 SITE PLAN A-2 FLOOR PLANS A-3 EXTERIOR ELEVATIONS A-4 BUILDING SECTIONS S-001 GEN. STRUCTURAL NOTES S-101 FND PLAN S-102 2ND FLR FRAMING PLAN S-103 ROOF FRAMING PLAN S-501 FND DETAILS S-510 FLOOR FRAMING DETAILS S-520 ROOF FRAMING DETAILS S-601 SCHEDULES S-602 SCHEDULES E-1 ELECTRICAL PLANS SITE PLAN SCALE: 1" = 10' JOB NUMBER CO R C O R A N 6 U N I T 35 8 S . 3 R D W E S T RE X B U R G I D A-1 REFERENCED CODES: 2018 INTERNATIONAL BUILDING CODE 2017 NATIONAL ELECTRICAL CODE 2018 MECHANICAL CODE OF IDAHO 2018 IDAHO COMMERCIAL ENERGY CODE 2018 IECC 2015 IDAHO PLUMBING CODE 2018 INTERNATIONAL FIRE CODE 2009 IDAHO ACCESSIBILITY CODE DR A W N B Y : DA R E N W A R D E L L 19 8 0 2 V I A R E D O N D A R D . SO N O R A C A 9 5 3 7 0 SNOW STORAGE AREA PAVED PARKING AREA 4.455 SF SNOW STORAGE AREA, 493 SF DEFERRED ITEMS: 1. FIRE SPRINKLERS, NFPA 13R. SPRINKLERS MUST BE QUICK RESPONSE 2. ENVELOPE COMM CHECK 1. ACCESSIBLE PATH SCALE: 1" = 5' A-5 TYPE B DWELLING REQUIREMENTS Landscape Plan needed to assess screening and sight triangle requirements 2 4 ft maneuv ering area required for 9 0 degree park ing. W hat siz e of trash receptacle w ill b e used? IF C 2 0 1 8 5 0 3 .1 .1 requires that a fire hy drant b e located w ith-in 1 5 0 ft. of the F ire D epartment connection. 2 0 ' access minimum IF C 5 0 3 .2 .1 R equires that the A ccess road b e a minimum w idth of 2 0 ft. S torm drainage calculations required.