HomeMy WebLinkAboutSITE PLAN - 23-00358 - Corcoran 6 Unit Apartments-Reviewed-Corrections-Required (2)Author Name Author Email Author Phone No.:
Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314
Joel Gray Joel.Gray@rexburg.org 208-372-2331
Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164
Katie Saurey Katie.Saurey@rexburg.org 208-372-2167
Description : Corcoran 6 Unit - Apartments
Address : 358 S 3rd W
Application Type :
Document Filename : SITE PLAN - 23-00358 - Corcoran 6 Unit Apartments.pdf Array
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Revisions Required
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
A-1 Callout Stan Crittenden : Fire Open 1 2018 International Fire Code
A-1 Free Text Stan Crittenden : Fire Open 1 IFC 2018 requires that a fire hydrant
be located a max. distance of 150 ft.
from the FDC
A-1 Callout Stan Crittenden : Fire Open 1 IFC 2018 Appendix D requires No parking signage both sides
of the access road
A-1 Free Text Kyle Baldwin : P&Z Open 1 Need snow storage area calculations, landscape plan.
Sidewalk in right-of-way must extend to parcel line and
internal sidewalks must connect to ROW sidewalk for
pedestrian connectivity
A-1 Callout Joel Gray : PW Open 1 Sidewalk must extend to parcel line and be ADA Compliant
A-1 Callout Joel Gray : PW Open 1 Trash enclosure not serviceable by truck.
A-1 Free Text Joel Gray : PW Open 1 Storm drainage calculations required.
A-1 Callout Joel Gray : PW Open 1 Existing water meter?
A-1 Callout Joel Gray : PW Open 1 Approach must be as wide as drive isle.
# 23-00358
New Multi-Family Residence
Please digitally re-submit all pages of the plan set in response to requested revisions
for our next review cycle, with noted items resolved.
Report Date: 06.21.2023
Approval of plans does not constitute approval of variance from code
Page 1 of 1
Powered by TCPDF (www.tcpdf.org)
VICINITY MAP
SCALE: N.T.S.
SUBJECT
PROPERTY
N
WA
T
E
R
C / W C / W C / W
20'
25'
1 0 '
1 0 '
2 0 '
20'
9 '
37'-10"
2 0 '
20'20'-3"
9'8'
S S S S S S
(N) 6 UNIT MULTIFAMILY
4/1
5/2
6/3
11
33
2
6
5
44
5
6
S.
3
R
D
W
E
S
T
115.50'
115.50'
82
.
5
0
'
82
.
5
0
'
NO
PARKING
STORM
WATER SERVICE
4" SANITARY SEWER
HEATED FIRE RISER &
ALARM PANEL ROOM
TRASH ENCLOSURE
(PERVIOUS PAVERS)
SNOW STORAGE
SNOW STORAGE
(N) SOLID FENCE
CONNECT ROOF
DRAINS TO D.I.
REVISIONS
SHEET:
SCALE:
DATE:
11
6/7/2023
PROJECT DATA:
A.P.N.RPR000P0103610
LOT SIZE .214 ACRES
OCCUPANCY R3/U
CONSTRUCTION TYPE VB
EXISTING RESIDENCE AREA 969 SF
EXISTING GARAGE AREA 200 SF
(N) 6 UNITS 3,480 SF
UNIT 1 575
UNIT 2 501
UNIT 3 661
UNIT 4 575
UNIT 5 501
UNIT 6 661
SCOPE OF WORK:
REMOVE (E) SINGLE DWELLING,
CONSTRUCT NEW 6 UNIT APARTMENT
BLDG.
SHEET INDEX:
A-1 SITE PLAN
A-2 FLOOR PLANS
A-3 EXTERIOR ELEVATIONS
A-4 BUILDING SECTIONS
S-001 GEN. STRUCTURAL NOTES
S-101 FND PLAN
S-102 2ND FLR FRAMING PLAN
S-103 ROOF FRAMING PLAN
S-501 FND DETAILS
S-510 FLOOR FRAMING DETAILS
S-520 ROOF FRAMING DETAILS
S-601 SCHEDULES
S-602 SCHEDULES
E-1 ELECTRICAL PLANS
SITE PLAN
SCALE: 1" = 10'
JOB NUMBER
CO
R
C
O
R
A
N
6
U
N
I
T
35
8
S
.
3
R
D
W
E
S
T
RE
X
B
U
R
G
I
D
A-1
REFERENCED CODES:
2018 INTERNATIONAL BUILDING CODE
2017 NATIONAL ELECTRICAL CODE
2018 MECHANICAL CODE OF IDAHO
2018 IDAHO COMMERCIAL ENERGY CODE
2018 IECC
2015 IDAHO PLUMBING CODE
2018 FIRE CODE OF IDAHO
2009 IDAHO ACCESSIBILITY CODE
DR
A
W
N
B
Y
:
DA
R
E
N
W
A
R
D
E
L
L
19
8
0
2
V
I
A
R
E
D
O
N
D
A
R
D
.
SO
N
O
R
A
C
A
9
5
3
7
0
IFC 2018 requires that a fire hydrant
be located a max. distance of 150 ft.
from the FDC
IFC 2018 A p p endix D
requires N o p ark ing
sig nag e both sides of
the access road
T rash enclosure not
serv iceable by truck .
A p p roach must
be as w ide as
driv e isle.
2018 International Fire
Code
E xisting w ater
meter?
S torm drainag e calculations required.
N eed snow storag e area calculations, landscap e p lan.
S idew alk in rig ht-of-w ay must extend to p arcel line and
internal sidew alk s must connect to R O W sidew alk for
p edestrian connectiv ity
S idew alk must
extend to p arcel
line and be A DA
Comp liant