HomeMy WebLinkAboutSOIL DENSITY TEST 4 - 23-00332 - Madison Jr High - AdditionFile Name: 23252D08102023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1fbaea54224c7895-1691699135287 1 4103 E. 605 N. Suite 1 Rigby ID, 83442 208.932.4428 In Place Density of Soils ASTM D2922 & D3017 Project Number: 23-252 Project Name: Madison JR. High Contractor: Hill and Son Client: Madison School District Date: 08/10/2023 Time Start: 02:00 PM Instrument ID 10483 Daily Standardization: MS: 798 DS: 1536 Current Weather Conditions: Partly Cloudy Ambient Temperature (°F): 80 Wind: 5-15 mph Details Test #:Location:Elevation: Depth:Wet:Dry:% M:Proctor #:% Proctor:Pass Fail 1 Interior footing East addition Bottom of footings 8 129.2 127.5 1.8 134.3 Material Type Pit Run 95 2 Interior footings East addition Bottom of footing 10 130.3 127.3 4.8 134.3 Material Type Pit Run 95 3 Interior footings East addition Bottom of footings 10 130.2 127.5 2.1 134.3 Material Type Pit Run 95 4 Interior footings East addition Bottom of footings 10 132.1 129.8 1.8 134.3 Material Type Pit Run 97 5 Exterior footings East addition Bottom of footings 10 130.1 127.4 2.1 134.3 Material Type Pit Run 95 6 Exterior footings East addition Bottom of footings 10 131.9 129.4 1.9 134.3 Material Type Pit Run 96 Observations/Remarks: File Name: 23252D08102023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1fbaea54224c7895-1691699135287 2 I arrived on site and met with Truman (Headwaters Construction) he informed me of the locations that they needed density testing on. I standardized my gauge and began testing the interior footings and exterior footings. Although the material was dry, due to it having been placed 3 weeks ago, passing density tests were obtained and reported. I notified the contractor of my observations and test results prior to leaving. Tested By: Jacob Christensen Signature: Reviewed By: E. Vail Signature: Date: 08/10/2023 Inspection Images: