HomeMy WebLinkAboutSTRUCTURAL CALCS - 23-00526 - Grand Peaks Medical - Addition GRAND PEAKS MEDICAL ADDITION STRUCTURAL DESIGN CALCULATIONS FOR THE NEW ADDITION TO GRAND PEAKS MEDICAL LOCATED AT 72 SOUTH 1ST EAST REXBURG, IDAHO Prepared For: Holt Architects Ithaca, New York Designed By: Mark D. Andrus, PE Project #23059 TABLE OF CONTENTS DESCRIPTION SHEET General Design Criteria 1.1 Design Load Calculations 2.1 – 2.8 Lateral Design 3.1 – 3.10 Roof Framing Design 4.1 – 4.6 Wall Framing Design 5.1 – 5.25 Foundation Design 6.1 – 6.17 G & S Structural Engineers 505 Lindsay Boulevard Idaho Falls, ID 83402 Telephone: (208) 523-6918 E-mail: gs@gsengineers.net 7-26-2023 G & S Structural Engineers 505 Lindsay Boulevard Idaho Falls, ID 83402 Telephone: (208) 523-6918 E-mail: gs@gsengineers.net GENERAL DESIGN CRITERIA Project: Grand Peaks Medical Addition (Project 23059) Location: Rexburg, Idaho Building Code: 2018 International Building Code (IBC) Design Loads: Roof: Snow Load (SL): 35 psf Dead Load (DL): 20 psf Floor: Live Load (LL): 100 psf 4” Concrete slab on grade Foundation: Allowable soil pressure: 2500psf Per the Geotechnical Engineering Study by Rocksmith Engineering dated June 16, 2023 Wind: 115 mph 3-second wind gust (Ultimate) 89-mph 3-second gust (Nominal) Exposure B Risk Category II Seismic: SS = 36.90 % g Sds = 0.370 g S1 = 14.30 % g Sd1 = 0.221 g Site class: D Seismic Design Category: B Risk Category II Importance Factor: IE = 1.0 R = 6.5, Wood framed bearing shear walls with OSB panels V = 0.057 W Equivalent lateral force analysis 20% of snow weight used for seismic force determination Sheet 1.1