HomeMy WebLinkAboutSTRUCTURAL CALCS - 23-00526 - Grand Peaks Medical - Addition
GRAND PEAKS MEDICAL
ADDITION
STRUCTURAL DESIGN CALCULATIONS
FOR THE NEW ADDITION TO
GRAND PEAKS MEDICAL
LOCATED AT
72 SOUTH 1ST EAST
REXBURG, IDAHO
Prepared For:
Holt Architects
Ithaca, New York
Designed By:
Mark D. Andrus, PE
Project #23059
TABLE OF CONTENTS
DESCRIPTION SHEET
General Design Criteria 1.1
Design Load Calculations 2.1 – 2.8
Lateral Design 3.1 – 3.10
Roof Framing Design 4.1 – 4.6
Wall Framing Design 5.1 – 5.25
Foundation Design 6.1 – 6.17
G & S Structural Engineers
505 Lindsay Boulevard
Idaho Falls, ID 83402
Telephone: (208) 523-6918 E-mail: gs@gsengineers.net
7-26-2023
G & S Structural Engineers
505 Lindsay Boulevard
Idaho Falls, ID 83402
Telephone: (208) 523-6918 E-mail: gs@gsengineers.net
GENERAL DESIGN CRITERIA
Project: Grand Peaks Medical Addition (Project 23059)
Location: Rexburg, Idaho
Building Code: 2018 International Building Code (IBC)
Design Loads:
Roof: Snow Load (SL): 35 psf
Dead Load (DL): 20 psf
Floor: Live Load (LL): 100 psf
4” Concrete slab on grade
Foundation: Allowable soil pressure: 2500psf
Per the Geotechnical Engineering Study by Rocksmith Engineering
dated June 16, 2023
Wind: 115 mph 3-second wind gust (Ultimate)
89-mph 3-second gust (Nominal)
Exposure B
Risk Category II
Seismic: SS = 36.90 % g Sds = 0.370 g
S1 = 14.30 % g Sd1 = 0.221 g
Site class: D
Seismic Design Category: B
Risk Category II
Importance Factor: IE = 1.0
R = 6.5, Wood framed bearing shear walls with OSB panels
V = 0.057 W
Equivalent lateral force analysis
20% of snow weight used for seismic force determination
Sheet 1.1