Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
VSUN DOCS - 23-00514 - 369 W 1st N - Solar Panels
FF0002 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 1 Certificate of Compliance Certificate: 80008066 Master Contract: 265697 Project: 80077950 Date Issued: 2021-08-09 Issued to: VIETNAM SUNERGY JOINT STOCK COMPANY Lot III-Dong Vang Area, Dinh Tram Industrial Zone, Hoang Ninh Commune,Viet Yen District, 230000 Bac Giang Province, VIETNAM The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only Issued by: Qiang (Sean) Jiang Qiang (Sean) Jiang PRODUCTS CLASS 5311 10 - POWER SUPPLIES - Photovoltaic Modules and Panels CLASS 5311 90 - POWER SUPPLIES - Photovoltaic Modules and Panels - Certified to U.S. Standards Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system voltage of 1500 V dc, model series: VSUNxxx-72MH-DG (xxx=350-375, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system voltage of 1500 V dc, model series: VSUNxxx-60MH-DG (xxx=295-315, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system voltage of 1500 V dc, model series: VSUNxxx-72BMH-DG (xxx=350-410, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system voltage of 1500 V dc, model series: VSUNxxx-60BMH-DG (xxx=295-335, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system voltage of 1500 V dc, model series: VS UNxxx-144BMH-DG (xxx=380-470, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system voltage of 1500 V dc, model series: VSUNxxx-120BMH-DG (xxx=325-390, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system voltage of 1500 V dc, model series: VSUNxxx-144BMH-DG (xxx=510-580, in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system voltage of 1500 V dc, model series: VSUNxxx-132BMH-DG (xxx=475-520, in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system voltage of 1500 V dc, model series: VSUNxxx-120BMH-DG (xxx=430-470, in steps of 5), Fuse rating 30A. Certificate: 80008066 Project: 80077950 Master Contract: 265697 Date Issued: 2021-08-09 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 2 Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 29, maximum system voltage of 1500 V dc, model series: VSUNxxx-108BMH-DG (xxx=390-410, in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Cla ss C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-72M(72M-BW/72M-BB) (xxx=330-420, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-72MH(72MH-BW) (xxx=330- 420, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Cla ss C, Fire Performance (USA) Type 1, maximum system voltage of 1500 V dc, model series: VSUNxxx-72BMH (xxx=350-410, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Cla ss C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-72P(72P-BW/72P-BB) (xxx=310-355, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-72PH(72PH-BW) (xxx=310-355, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-60M(60M-BW/60M-BB) (xxx=275-355, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-60MH(60MH-BW) (xxx=275- 355, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system voltage of 1500 V dc, model series: VSUNxxx-60BMH (xxx=295-335, in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Cana da): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-60P(60P-BW/60P-BB) (xxx=260-295, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-60PH(60PH-BW) (xxx=260-295 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-54M(54M-BW/54M-BB) (xxx=250-315, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-54MH(54MH-BW) (xxx=250- 315 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-54P(54P-BW/54P-BB) (xxx=235-265, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUN265-54PH(54PH-BW) (xxx=235-265 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-48M(48M-BW/48M-BB) (xxx=220-280, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-48MH(48MH-BW) (xxx=220- 280 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-48P(48P-BW/48P-BB) (xxx=210-235, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-48PH(48PH-BW) (xxx=210-235 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-36M(36M-BW/36M-BB) (xxx=165-210, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-36MH(36MH-BW) (xxx=165- 210 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire P erformance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-36P(36P-BW/36P-BB) (xxx=155-175, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-36PH(36PH-BW) (xxx=155-175 in steps of 5), Fuse rating 20A. Certificate: 80008066 Project: 80077950 Master Contract: 265697 Date Issued: 2021-08-09 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 3 Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-144M(144M-BW/144M-BB) (xxx=360-480, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-144MH(144MH-BW) (xxx=360- 480 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system voltage of 1500 V dc, model series: VSUNxxx-144BMH (xxx=380-470 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-144M(144M-BW/144M-BB) (xxx=510-580, in steps of 5), Fuse rating 30A or maximum system voltage of 1500 V dc, model series: VSUNxxx-144MH(144MH-BW) (xxx=510- 580 in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system voltage of 1500 V dc, model series: VSUNxxx-144BMH) (xxx=510-580 in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-132M(132M-BW/132M-BB) (xxx=355-385, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-132MH(132MH-BW) (xxx=355- 385 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-132M(132M-BW/132M-BB) (xxx=475-520, in steps of 5), Fuse rating 30A or maximum system voltage of 1500 V dc, model series: VSUNxxx-132MH(132MH-BW) (xxx=475- 520 in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system voltage of 1500 V dc, model series: VSUNxxx-132BMH (xxx=475-520 in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system voltage of 1500 V dc, model series: VSUNxxx-120BMH (xxx=325-390 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-120M(120M-BW/120M-BB) (xxx=310-400, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-120MH(120MH-BW) (xxx=310- 400 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-120M(120M-BW/120M-BB) (xxx=430-470, in steps of 5), Fuse rating 30A or maximum system voltage of 1500 V dc, model series: VSUNxxx-120MH(120MH-BW) (xxx=430- 470 in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system voltage of 1500 V dc, model series: VSUNxxx-120BMH) (xxx=430-470 in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-108M(108M-BW/108M-BB) (xxx=390-410, in steps of 5), Fuse rating 30A or maximum system voltage of 1500 V dc, model series: VSUNxxx-108MH(108MH-BW) (xxx=390- 410 in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system voltage of 1500 V dc, model series: VSUNxxx-108BMH (xxx=390-410 in steps of 5), Fuse rating 30A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-150M(150M-BW/150M-BB) (xxx=480-535, in steps of 5), Fuse rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-150MH(150MH-BW) (xxx=480- 535 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1 or 2, maximum system voltage of 1000 V dc, model series: VSUNxxx-156M(156M-BW/156M-BB) (xxx=425-500, in steps of 5), Fuse Certificate: 80008066 Project: 80077950 Master Contract: 265697 Date Issued: 2021-08-09 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 4 rating 20A or maximum system voltage of 1500 V dc, model series: VSUNxxx-156MH(156MH-BW) (xxx=425- 500 in steps of 5), Fuse rating 20A. Photovoltaic modules with Fire class (Canada): Class C, Fire Performance (USA) Type 1, maximum system voltage of 1500 V dc, model series: VSUNxxx-156BMH (xxx=465-500 in steps of 5), Fuse rating 20A. Notes: 1. The electrical characteristics are within ±3 percent of the indicated values of Isc, Voc, and Pmax under standard test conditions (irradiance of 100 mW/cm2, AM 1.5 spectrum, and a cell temperature of 25°C (77°F)), NOCT: 45ºC. 2. The operating ambient temperature of these devices may exceed 40 °C at full load for all wire sizes if it is determined suitable in the field use application. APPLICABLE REQUIREMENTS CSA CAN/CSA-C22.2 NO. 61730-1:11 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction - First Edition 2011-08; Update No. 1: October 2013. CSA CAN/CSA-C22.2 NO. 61730-1:11 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction - First Edition, Amendment 1:2013 to CAN/CSA-C22.2 No. 61730-1:11 October 2013. CSA CAN/CSA-C22.2 NO. 61730-1:11 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction - First Edition, Amendment 2:2015 to CAN/CSA-C22.2 No. 61730-1:11 February 2015. CSA CAN/CSA-C22.2 NO. 61730-2:11 Photovoltaic (PV) module safety qualification - Part 2: Requirements for testing - First Edition 2011-08; Update No. 1: October 2013. CSA CAN/CSA-C22.2 NO. 61730-2:11 Photovoltaic (PV) module safety qualification - Part 2: Requirements for testing - First Edition, Amendment 1:2013 to CAN/CSA-C22.2 No. 61730-2:11 October 2013. UL 61730-1 1st: Photovoltaic (PV) Module Safety Qualification – Part 1: Requirements for Construction, 2017-12-04, revision date 2020-04-30. UL 61730-2 1st: Photovoltaic (PV) Module Safety Qualification – Part 2: Requirements for Testing, 2017-12-04, revision date 2020-04-30. DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 1 Supplement to Certificate of Compliance Certificate: 80008066 Master Contract: 265697 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 80077950 2021-08-09 Update report 80008066 to add new factory (VIETNAM SUNERGY JOINT STOCK COMPANY locate at Lot CN-09.1, Thuan Thanh II Industrial Zone, Mao Dien Commune, Thuan Thanh District, 16000 Bac Ninh Province, VIETNAM); add new 108 cell series (108BMH/108M/108M-BW/108M- BB/108MH/108MH-BW/108BMH); add new module dimension for series VSUNxxx-144 and VSUNxxx-120; add the new cell connector and string connector manufacturer with same parameter as previous; add new connector for PV-ZH011-6B; add new connector and new cable and new diode for PV- TS11-20A; add new cable for PV-ZH011C-3x; add new connector and new diode for FT50xy; add new frame manufacturer with same material spec; add new position tape. 80073538 2021-04-16 Update report 80008066 to add new cell (S166-9BB-PERC-bifacial) for both single and double glass series. 80061686 2021-04-16 Update report 80008066 to add new junction box (FT50xy) 80062476 2021-03-29 Update report 80008066 to alternate new VSUNxxx-156BMH series (the construction and the material is identical with 144BMH), add new substrate TFB-30M (plus) and TFB-30 (plus), add new POE (T22 with C22), add new dimension of cross connector (5.0 x 0.25mm and 5.0 x 0.4mm), add new position tape (UV-100)), alternate new module dimension (2280 x 1048 x 35 or 2304 x 1048 x 35mm) for VSUNxxx-156 series, extend the power rating to 500W for VSUNxxx-156 series. 80062475 2021-03-29 Update report 80008066 to alternate cell (S166-9BB-PERC-bifacial) with new model series (VSUNxxx-144BMH, VSUNxxx-120BMH, VSUNxxx- 72BMH, VSUNxxx-60BMH). 80073544 2021-02-25 Update report 80008066 to add new cell (S182-10BB-PERC-bifacial Cell) for both single and double glass series, add a new cell ribbon design (10BB of 0.32mm diameter), add new module size (2256 or 2278 x 1133 x 35 mm, 2073 or 2093 x 1133 x 35 mm, 1892 or 1908 x 1133 x 35 mm), add new 132 cell double glass model (VSUNxxx-132BMH-DG). 80062643 2021-02-05 Update report 80008066 to add new junction box (HL4R5-X), revised the PV connector information for junction box model HL4R2-1, update the detail information of certificate standards. 80062478 2020-11-12 Update report 80008066 to add new VSUNxxx-156 series. Certificate: 70207391 Project: 80077950 Master Contract: 265697 Date Issued: 2021-08-09 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 2 80062477 2020-11-12 Update report 80008066 to add new cell (158.75 & 166 mm) made by VIETNAM BLUE, extend the power output rating for VSUNxxx-144BMH- DG and VSUNxxx-120BMH-DG series, update the module size of VSUNxxx-144, VSUNxxx-144BMH-DG and VSUNxxx-120BMH-DG series. 80046377 2020-10-14 Update report 80008066 to add two new diodes for PV-TS11-20A. 80052588 2020-09-16 Update report 80008066 to add new material for double glass model series (add new spec of superstrate made by CSG, extend the power output rating for 144BMH-DG and 144BMH-DG series, new POE B602 made by CHANGZHOU BBETTER FLIM TECHNOLOGIES CO., LTD., add a new string ribbon size made by Sunby, add new frame manufacturer YI YIN ENERGY VIETNAM CO., LTD., add a new dimension for 72BMH-DG series, add new adhesive (JS-606) and potting material (JS-1184) for PV- ZH011C-3x, add new position tape (FF-3665)). 80052587 2020-08-18 Update report 80008066 to add new material for single glass model series (add a new superstrate made by CSG, new cell (S158.75-5BB-PERC), add a new cell ribbon manufacturer (Sunby), add a new string ribbon manufacturer (Sunby), add a new EVA (B601HP&B601W), add a new substrate (HDPYE SPV L), add a new junction box (PV-TS08-12A) 80048138 2020-08-18 Update report 80008066 to increase the design loading to 3600Pa 80048137 2020-08-18 Update report 80008066 to add new 40mm height frame for single glass model series 80048135 2020-07-13 Update report 80008066 to add new model series (150MH/150MH- BW/150M/150M-BW/150M-BB), add three new cell (MC210-9BB, S158.75-9BB-PERC, S166-9BB-PERC), add a new cell ribbon (0.35mm diameter), add a new junction box (PV-ZH011C-3x), revised the fire performance type according the standard update 80042089 2020-05-28 Update report 80008066 to add new factory (VESOLAR COMPANY LIMTED) 80036994 2020-05-15 Update report 80008066 to add new VSUNxxx-144BMH-DG & VSUNxxx- 120BMH-DG series with new junction box PV-TS11-20A 80030928 2020-04-14 Update report 80008066 to add a new junction box (HL4R2-1) for single glass series 80030029 2020-04-07 Update report 80008066 to add a new factory (Vietnam - F2 as the profile) 80028397 2020-03-13 Update report 80008066 to add a new junction box (PV-ZH011-3D) for single glass series 80012951 2019-12-18 Update report 80008066 to add a new junction box and 4.0mm thick superstrate with same manufacturer for single glass series 80027462 2019-12-18 Update report 80008066 to add a new cell for single glass series Certificate: 70207391 Project: 80077950 Master Contract: 265697 Date Issued: 2021-08-09 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 3 80008627 2019-12-18 Update report 80008066 to extend the power rating for VSUNxxx-72BMH- DG and VSUNxxx-60BMH-DG series the following tests were considered necessary. 80018480 2019-09-18 Update report 80008066 to add new 158.75 cell for VSUNxxx-72BMH-DG and VSUNxxx-60BMH-DG series, extend the power rating for VSUNxxx- 72BMH-DG and VSUNxxx-60BMH-DG series, add new frame size for VSUNxxx-72BMH-DG and VSUNxxx-60BMH-DG series 70216830 2019-08-02 Update report 80008066 to add 12 series models 80008066 2019-06-25 Original certificate, full investigation for model series VSUNxxx-72BMH- DG, VSUNxxx-60BMH-DG, VSUNxxx-72MH-DG and VSUNxxx-60MH- DG QIMS2.E357716 - Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels - Component Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels - Component Photovoltaic module bonding devices, Cat. No. DynoBond 8", -12", -38", -46", -50", -76", -96" or DynoBond, followed by any length between 8” – 96”. and Cat no. DynoBond Terminator. Conditions of Acceptability: 1. These devices have been evaluated using representative sections of anodized aluminum frames, over a range of thickness and minimum flange capture depth. Compatibility with any Listed PV module frame must be determined in the end-use application. 2. These devices have been evaluated for bonding up to a maximum over-current protection level of 20 Amps through the Bonding Path Resistance Test, which was conducted before and after the Temperature Cycling Test, Humidity Test and Bonding Conductor Test, as outlined in UL 2703. Acceptability for use with specific grounding systems must be determined in the end-use application. 3. The DynoBond Bonding Clip, used on each end of the Bonding Jumpers and one end of the DynoBond Terminatorare attached to the modules using spring force and a piercing function to penetrate the anodized coating of the flat bottom portion of Listed Module frames. Acceptance of this interconnection as a grounding path shall be determined in the end- use application. 4. One end of the DynoBond Terminator is an open ended wire that may connect to a combiner box. The suitability of the connection shall be determined in the end-use application Marking: Company name, catalog designation and the Recognized Component Mark on the device or on the smallest unit container in which the product is packaged. Last Updated on 2022-01-05 The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL Solutions' Follow - Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL Solutions' Follow - Up Service. Always look for the Mark on the product. UL Solutions permits the reproduction of the material contained in Product iQ subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from Product iQ with permission from UL Solutions" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "©2023 UL LLC." DYNORAXX Suite 120 6500 Sheridan Dr Buffalo, NY 14221 United States E357716 Fe e d b a c k X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. IQ Combiner 4/4C To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Gateway for communication and control • Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat • Supports Wi-Fi, Ethernet, or cellular connectivity • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Mounts on single stud with centered brackets • Supports bottom, back and side conduit entry • Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) IQ-C-4-4C-DS-0103-EN-US-12-29-2022 © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. MODEL NUMBER IQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. IQ Combiner 4C X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8) Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws Consumption monitoring CT (CT-200-SPLIT/CT-200-CLAMP) A pair of 200A split core current transformers ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240VAC, 60 Hz Eaton BR series busbar rating 125A Max. continuous current rating 65A Max. continuous current rating (input from PV/storage)64A Max. fuse/circuit rating (output)90A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input)80A of distributed generation/95A with IQ Gateway breaker included IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway MECHANICAL DATA Dimensions (WxHxD)37.5 cm x 49.5 cm x 16.8 cm (14.75 in x 19.5 in x 6.63 in). Height is 53.5 cm (21.06 in) with mounting brackets. Weight 7.5 kg (16.5 lbs) Ambient temperature range -40ºC to +46ºC (-40ºF to 115ºF) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20A to 50A breaker inputs: 14 to 4 AWG copper conductors • 60A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors • Always follow local code requirements for conductor sizing. Altitude Up to 3,000 meters (9,842 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi IEEE 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations. Ethernet Optional, IEEE 802.3, Cat5E (or Cat6) UTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Combiner CA Rule 21 (UL 1741-SA) IEEE 1547:2018 - UL 1741-SB, 3rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 IQ Combiner 4/4C IQ-C-4-4C-DS-0103-EN-US-12-29-2022 DATA SHEET IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Easy to install • Lightweight and compact with plug-n- play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB 3rd Ed.) Note: IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, etc) in the same system. © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. *Only when installed with IQ System Controller 2, meets UL 1741. **IQ8 and IQ8Plus support split-phase, 240V installations only. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer’s instructions. IQ8SP-12A-DS-0067-03-EN-US-2022-12-27 (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://link.enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8 and IQ8+ Microinverters INPUT DATA (DC)IQ8-60-2-US IQ8PLUS-72-2-US Commonly used module pairings1 W 235 – 350 235 – 440 Module compatibility 60-cell / 120 half-cell 54-cell / 108 half-cell, 60-cell / 120 half-cell, 66-cell / 132 half- cell and 72-cell / 144 half-cell MPPT voltage range V 27 – 37 27 – 45 Operating range V 16 – 48 16 – 58 Min. / Max. start voltage V 22 / 48 22 / 58 Max. input DC voltage V 50 60 Max. continuous input DC current A 10 12 Max. input DC short-circuit current A 25 Max. module Isc A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8-60-2-US IQ8PLUS-72-2-US Peak output power VA 245 300 Max. continuous output power VA 240 290 Nominal (L-L) voltage / range2 V 240 / 211 – 264 Max. continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 47 – 68 AC short circuit fault current over 3 cycles Arms 2 Max. units per 20 A (L-L) branch circuit3 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.7 CEC weighted efficiency %97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to +60°C (-40°F to +140°F) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (H x W x D)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB 3rd Ed.), FCC Part 15 Class B, ICES-0003 Class B, CAN / CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8SP-12A-DS-0067-03-EN-US-2022-12-27 CERTIFICATE OF COMPLIANCE Certificate Number E493748 Report Reference E493748-20170817 Date 2023-April-07 Deborah Jennings-Conner, VP Regulatory Services UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Issued to:QuickBOLT a Division of Quickscrews International Corp 5830 Las Positas Rd Livermore CA, 94551 US MOUNTING SYSTEMS, MOUNTING DEVICES, CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS - COMPONENT This is to certify that representative samples of See Addendum Page for Product Designation(s). Have been evaluated by UL in accordance with the component requirements in the Standard(s) indicated on this Certificate. UL Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for installation in complete equipment submitted for investigation to UL LLC. Standard(s) for Safety:UL 2703, Mounting systems, mounting devices, clamping/retention devices, and ground lugs for use with flat- plate photovoltaic modules and panels-. Additional Information:See the UL Online Certifications Directory at https://iq.ulprospector.com for additional information This Certificate of Compliance indicates that representative samples of the product described in the certification report have met the requirements for UL certification. It does not provide authorization to apply the UL Recognized Component Mark. Only the Authorization Page that references the Follow-Up Services Procedure for ongoing surveillance provides authorization to apply the UL Mark. Only those products bearing the UL Recognized Component Mark should be considered as being UL Certified and covered under UL’s Follow-Up Services. Look for the UL Recognized Component Mark on the product. CERTIFICATE OF COMPLIANCE Certificate Number E493748 Report Reference E493748-20170817 Date 2023-April-07 Deborah Jennings-Conner, VP Regulatory Services UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements Models: USR – Component, Roof Mounting Hook Units, Models 15891 15893 15987 16000 16317 16318 16319 16320 16988 16990 16991 16993 17508 17509 17510 17511 17512 17513 17514 17515 17516 17517 17518 17519 17520 17521 17522 17523 17524 17525 17526 17527 17536 17537 17538 17539 17540 17541 17542 17543 17544 17545 17546 17547 17548 17549 17550 17551 17552 17553 17554 17555 17556 17558 17559 17560 17566 17567 17568 17569 17570 17571 17572 17573 17574 17575 17576 17577 17578 17579 17580 17585 17586 17587 17588 17589 17592 17596 17597 17598 17599 17600 17601 17606 17607 17608 17609 17610 17611 17612 17613 17614 17615 17616 17617 17618 17620 17621 17622 17623 17624 17625 17626 17627 17628 17629 17630 17631 17632 17633 17636 17637 17638 17639 17640 17641 17642 17643 17646 17647 17648 17649 17650 17651 17652 17653 17654 17659 17664 17667 17669 17670 17671 17672 17673 17678 17679 17680 17681 17686 17687 17688 17689 17700 17701 17702 17703 17704 17705 17706 17707 17708 17709 17710 17711 17712 17717 17718 17750 17751 17752 17753 17759 15891-10 15891BLK-10 15987A 15987B 17667SS 17672SS 17680SS 17688SS 17713SS 17720 17721SS 17723 17724SS 17726 17727SS 17729 17730SS 15894SS 15891SS 15987BSS 17660 17661 17662 17663 17747 17748