Loading...
HomeMy WebLinkAboutUPDATED PLANS - 23-00501 - 363 E 2nd S - Solar Panels. \ H o u s e P h o t o . J P G . \ V i c i n i t y M a p . J P G R E V S H E E T N A M E S H E E T S I Z E S H E E T N U M B E R STEVEN, DRESEN RESIDENCE 363 E SECOND SOUTH REXBURG, REXBURG, ID 83440 A N S I B 1 1 " X 1 7 " D A T E D E S C R I P T I O N R E V I S I O N S P R O J E C T N A M E & A D D R E S S D A T E : 0 7 / 2 7 / 2 0 2 3 D R A W N B Y P E R M I T S O L A R P L A T I N U M S O L A R . 9 5 3 W 7 0 0 N S U I T E 1 1 2 L O G A N , U T A H 8 4 3 2 1 U S A E m a i l : i n f o @ p l a t i n u m s o l a r . c o m . \ P l a t i n u m + S o l a r . p n g PROJECT DATA G E N E R A L N O T E S V I C I N I T Y M A P SHEET INDEX C O D E R E F E R E N C E S P R O J E C T T O C O M P L Y W I T H T H E F O L L O W I N G : 2 0 1 5 I N T E R N A T I O N A L R E S I D E N T I A L C O D E 2 0 2 0 N A T I O N A L E L E C T R I C A L C O D E 1. ALL COMPONENTS ARE UL LIS T E D A N D N E C C E R T I F I E D , W H E R E W A R R A N T E D . 2. ATTATCHMENT FEET WILL BE F I L E D A D J U S T E D T O A C C O M O D A T E T R U S S P O S I T I O N I N G S . 3. THE UTILITY INTERCONNECTI O N A P P L I C A T I O N M U S T B E A P P R O V E D A N D P V S Y S T E M I N S P E C T E D P R I O R T O P A R A L L E L OPERATION.4. ALL CONDUCTORS OF A CIRC U I T , I N C L U D I N G T H E E G C , M U S T B E I N S T A L L E D I N T H E S A M E R A C E W A Y , O R C A B L E , O R OTHERWISE RUN WITH THE PV A R R A Y C I R C U I T C O N D U C T O R S W H E N T H E Y L E A V E T H E V I C I N I T Y O F T H E P V A R R A Y . 5. ALL INSTALLATIONS SHALL CO M P L Y W I T H 2 0 1 5 I R C & 2 0 2 0 N E C . 6. A GROUNDING ELECTRODE SY S T E M I N A C C O R D A N C E W I T H N E C 6 9 0 . 4 7 A N D 2 5 0 . 5 0 T H R O U G H 6 0 A N D 2 5 0 - 1 6 6 S H A L L B E PROVIDED. PER NEC GROUNDI N G E L E C T R O D E S Y S T E M O F E X I S T I N G B U I L D I N G M A Y B E U S E D A N D B O N D E D T O T H E S E R V I C E ENTRANCE. IF EXISTING SYST E M I S I N A C C E S S I B L E O R I N A D E Q U A T E A S U P P L E M E N T A L G R O U N D I N G E L E C T R O D E W I L L B E U S E D AT THE INVERTER LOCATION C O N S I S T I N G O F A U L L I S T E D 8 F T . G R O U N D R O D W I T H A C O R N C L A M P . G R O U N D I N G E L E C T R O D E CONDUCTORS SHALL BE NO L E S S T H A N # 8 A W G A N D N O L A R G E R T H A N # 6 A W G C O P P E R A N D B O N D E D T O T H E E X I S T I N G GROUNDING ELECTRODE TO P R O V I D E F O R A C O M P L E T E S Y S T E M . 7. PHOTOVOLTAIC MODULES AR E T O B E C O N S I D E R E D N O N - C O M B U S T I B L E . 8. PHOTOVOLTAIC INSTALLATION W I L L N O T O B S T R U C T A N Y P L U M B I N G . M E C H A N I C A L , O R B U I L D I N G R O O F V E N T S . 9. ALL WIRING MUST BE PROPER L Y S U P P O R T E D B Y D E V I C E S O R M E C H A N I C A L M E A N S D E S I G N E D A N D L I S T E D F O R S U C H U S E . WIRING MUST BE PERMANENT L Y A N D C O M P L E T E L Y H E L D O F F T H E R O O F S U R F A C E . 10. ALL SINAGE TO BE PLACED IN A C C O R D A N C E W I T H T H E L O C A L B U I L D I N G C O D E . I F E X P O S E D T O S U N L I G H T , I T S H A L L B E U V RESISTANT. ALL PLAQUES AN D S I N A G E W I L L B E I N S T A L L E D A S R E Q U I R E D B Y T H E N E C A N D A H J . 11. AS SPECIFIED BY THE AHJ, EQ U I P M E N T U S E D I N U N G R O U N D E D S Y S T E M S L A B E L E D A C C O R D I N G T O N E C 6 9 0 . 3 5 ( F ) . 12. INVERTER(S) USED IN UNGRO U N D E D S Y S T E M S H A L L B E L I S T E D F O R T H I S U S E [ N E C 6 9 0 . 3 5 ( G ) ] . 13. THE INSTALLATION OF EQUIP M E N T A N D A L L A S S O C I A T E D W I R I N G A N D I N T E R C O N N E C T I O N S H A L L B E P E R F O R M E D O N L Y B Y QUALIFIED PERSONS [NEC 690 . 4 ( C ) ] 14. ALL OUTDOOR EQUIPMENT SH A L L B E N E M A 3 R R A T E D ( O R B E T T E R ) , I N C L U D I N G A L L R O O F M O U N T E D T R A N S I T I O N B O X E S A N D SWITCHES.15. ALL EQUIPMENT SHALL BE PR O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H N E C A R T I C L E 2 5 0 . 16. SYSTEM GROUNDING SHALL B E I N A C C O R D A N C E W I T H N E C 6 9 0 . 4 1 . 17. PV SYSTEM CIRCUITS INSTALL E D O N O R I N B U I L D I N G S S H A L L I N C L U D E A R A P I D S H U T D O W N F U N C T I O N I N A C C O R D A N C E W I T H NEC 690.1218. DISCONNECTING MEANS SHAL L B E L O C A T E D I N A V I S I B L E , R E A D I L Y A C C E S S I B L E L O C A T I O N W I T H I N T H E P V S Y S T E M EQUIPMENT OR A MAXIMUM O F 1 0 F E E T A W A Y F R O M T H E S Y S T E M [ N E C 6 9 0 . 1 3 ( A ) ] 19. ALL WIRING METHODS SHALL B E I N A C C O R D A N C E W I T H N E C 6 9 0 . 3 1 20. WORK CLEARANCES AROUND E L E C T R I C A L E Q U I P M E N T W I L L B E M A I N T A I N E D P E R N E C 1 1 0 . 2 6 ( A ) ( 1 ) , 1 1 0 . 2 6 ( A ) ( 2 ) A N D 1 1 0 . 2 6 ( A ) ( 3 ) . 21. ROOFTOP MOUNTED PHOTOV O L T A I C P A N E L S A N D M O D U L E S S H A L L B E T E S T E D , L I S T E D & I D E N T I F I E D I N A C C O R D A N C E W I T H UL170322. ELECTRICAL CONTRACTOR TO P R O V I D E C O N D U I T E X P A N S I O N J O I N T S A N D A N C H O R C O N D U I T R U N S A S R E Q U I R E D P E R N E C . PROJECTADDRESS363 E SECOND SOUTHREXBURG,REXBURG, ID 83440OWNER:STEVEN, DRESENCONTRACTOR:PLATINUM SOLAR.953 W 700 N SUITE 112LOGAN, UTAH 84321DESIGNER:PERMITSOLARSCOPE:5.135 KW DC ROOF MOUNTSOLAR PV SYSTEM WITH13 TRINA SOLAR TSM-DE09C.07 395W PVMODULES &07 APSYSTEMS DS3-S MICROINVERTER H O U S E P H O T O C O V E R S H E E T PHOTOVOLTA I C R O O F M O U N T S Y S T E M 13 MODULES-ROOF MO U N T E D - 5 . 1 3 5 k W W A T T S D C , 4 . 4 8 0 k W W A T T S A C 363 E SECO N D S O U T H R E X B U R G , R E X B U R G , I D 8 3 4 4 0 PV-1 COVER SHEETPV-2 PLOT PLAN WITH ROOF PLANPV-3 ROOF PLAN & MODULESPV-4 ELECTRICAL PLANPV-5 ATTACHMENT DETAILPV-6 ELECTRICAL LINE DIAGRAMPV-7 WIRING CALCULATIONPV-8 LABELSPV-9 PLACARDPV-10 MICROINVERTER CHART P V - 1 PARCEL ID:N/ALICENSE #:UT # 11599147-5501ID # 059595BRYNER DESIGN ENGINEERINGLICENSE NO. 8186355(435) 994-4630MARKBRYNER@BRYNERDESIGN.COM444 BIRCH CIRCLENORTH LOGAN, UTAH 84341ENGINEERING LETTER ATTACHED HASSPECIFICATIONS FOR WIND AND LOADCALCULATIONS FOR SOLAR INSTALLATIONSPANS & ATTACHMENTS TO MEET LOCALAND STATE BUILDING CODE COMPLIANCE.STRUCTURAL ENGINEERING : UM MSP R E V S H E E T N A M E S H E E T S I Z E S H E E T N U M B E R STEVEN, DRESEN RESIDENCE 363 E SECOND SOUTH REXBURG, REXBURG, ID 83440 A N S I B 1 1 " X 1 7 " D A T E D E S C R I P T I O N R E V I S I O N S P R O J E C T N A M E & A D D R E S S D A T E : 0 7 / 2 7 / 2 0 2 3 D R A W N B Y P E R M I T S O L A R P L A T I N U M S O L A R . 9 5 3 W 7 0 0 N S U I T E 1 1 2 L O G A N , U T A H 8 4 3 2 1 U S A E m a i l : i n f o @ p l a t i n u m s o l a r . c o m . \ P l a t i n u m + S o l a r . p n g 1PLOT PLAN WITH ROOF PLANSCALE: 1/16" = 1'-0"PV-2 P V - 2 P L O T P L A N W I T H R O O F P L A N PROJECT DESCRIPTION:13 x TRINA SOLAR TSM-DE09C.07 395W PV MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESDC SYSTEM SIZE: 5.135kW DCAC SYSTEM SIZE: 4.480kW ACROOF ARRAY AREA #1:- 305.89 SQ FT.EQUIPMENT SUMMARY13 TRINA SOLAR TSM-DE09C.07 395W PV MODULES07 APSYSTEMS DS3-SMICROINVERTER P R O P E R T Y L I N E P R O P E R T Y L I N E PROPE R T Y L I N E PROPERTY LINE E S E C O N D S O U T H R E X B U R G E X I S T I N G D R I V E W A Y ARRAY #1 ( E ) U T I L I T Y M E T E R ( E ) M A I N S E R V I C E P A N E L ( I N S I D E ) 1 - S T O R Y H O U S E 1'-6"10'-11"8'-9"1 0 ' - 0 " 2 9 ' - 1 " 2 1 ' - 1 " R E V S H E E T N A M E S H E E T S I Z E S H E E T N U M B E R STEVEN, DRESEN RESIDENCE 363 E SECOND SOUTH REXBURG, REXBURG, ID 83440 A N S I B 1 1 " X 1 7 " D A T E D E S C R I P T I O N R E V I S I O N S P R O J E C T N A M E & A D D R E S S D A T E : 0 7 / 2 7 / 2 0 2 3 D R A W N B Y P E R M I T S O L A R P L A T I N U M S O L A R . 9 5 3 W 7 0 0 N S U I T E 1 1 2 L O G A N , U T A H 8 4 3 2 1 U S A E m a i l : i n f o @ p l a t i n u m s o l a r . c o m . \ P l a t i n u m + S o l a r . p n g MODULE TYPE, DIMENSIONS & WEIGHT1ROOF PLAN & MODULESPV-3SCALE: 1/8" = 1'-0" R O O F P L A N & M O D U L E S NUMBER OF MODULES = 13 MODULESMODULE TYPE = TRINA SOLAR TSM-DE09C.07 395 MODULESMODULE WEIGHT = 46.3 LBS / 21.0KG.MODULE DIMENSIONS = 69.0" x 43.1" = 23.53 SF T R I N A S O L A R T S M - D E 0 9 C . 0 7 3 9 5 M O D U L E S 69.0" 4 3 . 1 " P V - 3 ROOF DESCRIPTIONROOF TYPECOMP SHINGLEROOF LAYER1 LAYERSROOFROOFPITCHAZIMUTHTRUSSSIZETRUSSSPACING#127°180°2X4 24" A R R A Y # 1 (14) R O C K - I T C O U P L I N G (29) ECOFASTEN ROCK-IT MOUNT ATTACHME N T S ( N ) S K I R T ARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)#113 305.89 1011.19 30 R O O F # 1 P I T C H - 2 7 A Z I M . - 1 8 0 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 3 6 " F I R E S E T B A C K 36" FIRE SETBACK UM J B AC MSP LC R E V S H E E T N A M E S H E E T S I Z E S H E E T N U M B E R STEVEN, DRESEN RESIDENCE 363 E SECOND SOUTH REXBURG, REXBURG, ID 83440 A N S I B 1 1 " X 1 7 " D A T E D E S C R I P T I O N R E V I S I O N S P R O J E C T N A M E & A D D R E S S D A T E : 0 7 / 2 7 / 2 0 2 3 D R A W N B Y P E R M I T S O L A R P L A T I N U M S O L A R . 9 5 3 W 7 0 0 N S U I T E 1 1 2 L O G A N , U T A H 8 4 3 2 1 U S A E m a i l : i n f o @ p l a t i n u m s o l a r . c o m . \ P l a t i n u m + S o l a r . p n g 1ELECTRICAL PLANPV-4 E L E C T R I C A L P L A N BILL OF MATERIALSEQUIPMENT QTYDESCRIPTIONSOLAR PV MODULES13TRINA SOLAR TSM-DE09C.07 395INVERTER7 APSYSTEMS DS3-S MICROINVERTERATTACHMENTS29ECOFASTEN ROCK-IT MOUNTCOUPLINGS14 ECOFASTEN ROCK-IT COUPLING P V - 4 SCALE: 1/8" = 1'-0" C I R C U I T L E G E N D S ( N ) E M T C O N D U I T ( N ) J U N C T I O N B O X ( N ) A C D I S C O N N E C T # 1 ( E ) U T I L I T Y M E T E R C I R C U I T # 1 C I R C U I T # 1 ( 7 M O D U L E S ) CIR C U I T # 2 (6 MO D U L E S ) C I R C U I T # 2 ( 0 7 ) A P S Y S T E M S D S 3 - S M I C R O I N V E R T E R ( N ) L O A D C E N T E R ( E ) M A I N S E R V I C E P A N E L ( I N S I D E ) R E V S H E E T N A M E S H E E T S I Z E S H E E T N U M B E R STEVEN, DRESEN RESIDENCE 363 E SECOND SOUTH REXBURG, REXBURG, ID 83440 A N S I B 1 1 " X 1 7 " D A T E D E S C R I P T I O N R E V I S I O N S P R O J E C T N A M E & A D D R E S S D A T E : 0 7 / 2 7 / 2 0 2 3 D R A W N B Y P E R M I T S O L A R P L A T I N U M S O L A R . 9 5 3 W 7 0 0 N S U I T E 1 1 2 L O G A N , U T A H 8 4 3 2 1 U S A E m a i l : i n f o @ p l a t i n u m s o l a r . c o m . \ P l a t i n u m + S o l a r . p n g A T T A C H M E N T D E T A I L P V - 5 5/16"x3/8"HEX FLANGE BOLT300 SERIES SS S I D E V I E W MIN 5/16" DIAMSS LAG SCREWTORQUE=13±2 FT-LBS. C O M P S H I N G L E S M E T A L F L A S H I N G ROCK-IT SLIDEMETALFLASHINGCOMP SHINGLES ROCK-IT COUPLINGMID CLAMPROCK-ITPEDESTALSS LAG SCREWTORQUE=13±2 FT-LBS.EPDM BONDED WASHERFORMS WATERTIGHT SEAL 2 S 1 . 0 SECTION VIEW R O C K - I T S L I D E S I D E V I E W T O P V I E W R O C K - I T 3 . 0 C O U P L I N G M I D C L A M P R O C K - I T C O U P L I N G S H E L F T I E P L A T E 5 / 1 6 " x 1 1 / 2 " H E X F L A N G E B O L T 3 0 0 S E R I E S S S 2 1/2" MIN C O U P L I N G C L A M P + A T T A C H M E N T C O U P L I N G C L A M P + A T T A C H M E N T L = P O R T R A I T C L A M P S P A C I N G P E R M I T T E D C L A M P S P A C I N G M O D U L E L = L A N D S C A P E C L A M P S P A C I N G M O D U L E M O D U L E COUPLING R A F T E R C L A M P R A F T E R CANTILEVER L/3 OR LESS R A F T E R S 1 . 0 5 M O D U L E S I N P O R T R A I T / L A N D S C A P E N O T T O S C A L E S 1.0 4PV SYSTEM MOUNTI N G D E T A I L NOT TO SCALES 1.0 3SECTION VIEWNOT TO SCALES 1.0 6PV ARRAY TYP. ELEV A T I O N NOT TO SCALE PV MODULE, TYP. MOUNTTO FRAMING OF EXISTINGROOF TYPE, PARALLELWITH PLANE OF ROOF 1 S 1 . 0 S 1 . 0 7 C O N D U I T M O U N T I N G D E T A I L N O T T O S C A L E 3" MIN AND 6" MAX BETWEEN TO P O F R O O F A N D B O T T O M O F M O D U L E C O N D U I T O N E H O L E S T E E L S T R A P C O N D U I T M O U N T B R A C K E T F L A S H I N G O R T I L E S T R A P 6" MAXIMUM L A N D S C A P E = M A X 7 2 " ( 6 ' - 0 " ) P O R T R A I T = M A X 4 8 " ( 4 ' - 0 " ) S 1.0 8ILSCO SGB-4 GROUNDING LUGSNOT TO SCALE 1 1/2" I S O M E T R I C V I E W R O C K - I T C O U P L I N G M I D C L A M P R O C K - I T C O U P L I N G S H E L F S 1 . 0 2 R O C K - I T C O U P L I N G A S S E M B L Y N O T T O S C A L E S 1.0 1ROCK-IT MOUNT DE T A I L NOT TO SCALE GENERAL STRUCTURAL NOTES:1. THE SOLAR PANELS ARE TO BEMOUNTED TO THE ROOF FRAMING USINGTHE ROCK-IT SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BESPACED AS SHOWN IN THE DETAILS,AND MUST BE STAGGERED TOADJACENT FRAMING MEMBERS TOSPREAD OUT THE ADDITIONAL LOAD.2. UNLESS NOTED OTHERWISE, MOUNTINGANCHORS SHALL BE 5/16" LAG SCREWSWITH A MINIMUM OF 2-1/2" PENETRATIONINTO ROOF FRAMING.3. THE PROPOSED PV SYSTEM ADDS 2.6 psfTO THE ROOF FRAMING SYSTEM. 2 X 4 T R U S S A T 2 4 O . C . L 1 L 2 G 1 2 BRANCHTERMINATOR(ET-TERM) G N 2 0 A 2 0 A - +2- +1==BRANCH #1 L 1 L 2 JUNCTION B O X , 600V, NE M A 3 R , UL LIST E D 76 ( N ) L O A D C E N T E R 1 0 0 A , 2 4 0 V TRINA SOLARTSM-DE09C.07 MODULESAPSYSTEMS DS3-SMICROINVERTER - +2- +1==BRANCH #265 M T O U T I L I T Y G R I D L 1 L 2 N L O A D / L I N E S I D E I N T E R C O N N E C T I O N A T M A I N P A N E L P E R A R T . 7 0 5 . 1 2 L 1 L 2 ( E ) M A I N B R E A K E R T O H O U S E 2 4 0 V , 2 0 0 A / 2 P ( T O P F E D ) G E C G N ( E ) E X I S T I N G G R O U N D I N G E L E C T R O D E S Y S T E M N G 3 B I - D I R E C T I O N A L U T I L I T Y M E T E R 1 2 0 / 2 4 0 V 1 ɸ , 3 - W ( E ) M A I N P A N E L , 1 2 0 / 2 4 0 V , 1 ɸ , 3 W 2 2 5 A R A T E D L O A D G L 1 L 2 N G 3 N V I S I B L E , L O C K A B L E , L A B E L E D A C D I S C O N N E C T L O C A T E D W I T H I N 3 ' O F U T I L I T Y M E T E R L I N E P V A C D I S C O N N E C T 2 4 0 V , 1 ɸ , 3 W 6 0 A R A T E D N E M A 3 R 4 0 A / 2 P B A C K F E E D B R E A K E R R E F 2 0 2 0 N E C 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( b ) 2 0 1 4 N E C 7 0 5 . 1 2 ( D ) ( 2 ) ( 3 ) ( b ) R E V S H E E T N A M E S H E E T S I Z E S H E E T N U M B E R STEVEN, DRESEN RESIDENCE 363 E SECOND SOUTH REXBURG, REXBURG, ID 83440 A N S I B 1 1 " X 1 7 " D A T E D E S C R I P T I O N R E V I S I O N S P R O J E C T N A M E & A D D R E S S D A T E : 0 7 / 2 7 / 2 0 2 3 D R A W N B Y P E R M I T S O L A R P L A T I N U M S O L A R . 9 5 3 W 7 0 0 N S U I T E 1 1 2 L O G A N , U T A H 8 4 3 2 1 U S A E m a i l : i n f o @ p l a t i n u m s o l a r . c o m . \ P l a t i n u m + S o l a r . p n g E L E C T R I C A L L I N E D I A G R A M 1ELECTRICAL LINE DIAGRAMPV-6SCALE: NTS DC SYSTEM SIZE: 5.135 kW DCAC SYSTEM SIZE: 4.480 kW AC(13) TRINA SOLAR TSM-DE09C.07 395W MODULESWITH (07) APSYSTEMS DS3-S MICROINVERTER(1) STRING OF 07 MODULES CONNECTED IN SERIES(1) STRING OF 06 MODULES CONNECTED IN SERIES P V - 6 Q T Y C O N D U C T O R I N F O R M A T I O N C O N D U I T T Y P E C O N D U I T S I Z E ( 4 ) # 1 2 A W G - E N G A G E C A B L E ( L 1 & L 2 N O N U E T R A L ) N / A N / A ( 1 ) # 6 A W G - B A R E C O P P E R I N F R E E A I R ( 4 ) # 1 0 A W G - T H W N - 2 L 1 & L 2 E M T O R L F M C I N A T T I C 3 / 4 " ( 1 ) # 1 0 A W G - T H W N - 2 G N D ( 2 ) # 8 A W G - T H W N - 2 L 1 & L 2 E M T , L F M C O R P V C 3 / 4 " ( 1 ) T H W N - 2 N ( 1 ) # 8 A W G - T H W N - 2 G N D 1 2 3 # 8 A W G - R E V S H E E T N A M E S H E E T S I Z E S H E E T N U M B E R STEVEN, DRESEN RESIDENCE 363 E SECOND SOUTH REXBURG, REXBURG, ID 83440 A N S I B 1 1 " X 1 7 " D A T E D E S C R I P T I O N R E V I S I O N S P R O J E C T N A M E & A D D R E S S D A T E : 0 7 / 2 7 / 2 0 2 3 D R A W N B Y P E R M I T S O L A R P L A T I N U M S O L A R . 9 5 3 W 7 0 0 N S U I T E 1 1 2 L O G A N , U T A H 8 4 3 2 1 U S A E m a i l : i n f o @ p l a t i n u m s o l a r . c o m . \ P l a t i n u m + S o l a r . p n g W I R I N G C A L C U L A T I O N S P V - 7 ELECTRICAL NOTES1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APP L I C A T I O N . 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET E N V I R O N M E N T . 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED D I R E C T L Y T O , A N D L O C A T E D A S C L O S E A S POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMEN T S H A L L C O M P L Y W I T H N E C 1 1 0 . 2 6 . 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR S H A L L F U R N I S H A L L N E C E S S A R Y O U T L E T S , SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STA N D A R D S . 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIF I E D , T H E C O N T R A C T O R S H A L L S I Z E T H E M ACCORDINGLY.7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISI B L E . 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND M O D U L E S U P P O R T R A I L , P E R T H E GROUNDING CLIP MANUFACTURER'S INSTRUCTION.9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEE B L U G O R I L S C O G B L - 4 D B T L A Y - I N L U G . 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE P E R C E N T O F V A L U E S N U M B E R O F C U R R E N T C A R R Y I N G C O N D U C T O R S I N E M T . 8 0 4 - 6 . 7 0 7 - 9 . 5 0 1 0 - 2 0 A M B I E N T T E M P E R A T U R E S P E C S R E C O R D L O W T E M P - 2 4 ° A M B I E N T T E M P ( H I G H T E M P 2 % ) 3 4 ° C O N D U C T O R T E M P E R A T U R E R A T E 9 0 ° M O D U L E T E M P E R A T U R E C O E F F I C I E N T O F V o c - 0 . 2 5 C SOLAR M O D U L E S P E C I F I C A T I O N S MANUFACTURER / MODEL # T R I N A S O L A R T S M - D E 0 9 C . 0 7 3 9 5 M O D U L E VMP 3 4 . 0 V IMP 1 1 . 6 2 A VOC 4 1 . 0 V ISC 1 2 . 2 1 A TEMP. COEFF. VOC - 0 . 2 5 MODULE DIMENSION 6 9 . 0 " L x 4 3 . 1 " W x 1 . 3 8 " D ( I n I n c h ) ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN CALCULATED USING T H E M A N U F A C T U R E S CALCULATOR BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE C O E F I C I E N T S . INVERTER SPECIFICATIONSMANUFACTURER / MODEL # APSYSTEMS DS3-S MICROINVERTERMIN/MAX DC VOLT RATING 26V MIN/ 60V MAXMAX INPUT POWER265W-660WNOMINAL AC VOLTAGE RATING 240V/ 211-264VMAX AC CURRENT2.66AMAX MODULES PER CIRCUIT6 (SINGLE PHASE)MAX OUTPUT POWER640 VA A C F E E D E R C A L C U L A T I O N S CIRCUIT ORIGINCIRCIUTDESTINATIONVOLTAGE (V)FULL LOADAMPS "FLA"(A)FLA*1.25 (A)OCPD SIZE(A)NEUTRAL SIZEGROUND SIZECON D U C T O R S I Z E 7 5 ° C A M P A C I T Y ( A ) A M P A C I T Y C H E C K # 1 A M B I E N T T E M P . ( ° C ) T O T A L C C C O N D U C T O R S I N R A C E W A Y 9 0 ° C A M P A C I T Y ( A ) D E R A T I O N F A C T O R F O R A M B I E N T T E M P E R A T U R E N E C 3 1 0 . 1 5 ( B ) ( 2 ) ( a ) D E R A T I O N F A C T O R F O R C O N D U C T O R S P E R R A C E W A Y N E C 3 1 0 . 1 5 ( B ) ( 3 ) ( a ) 9 0 ° C A M P A C I T Y D E R A T E D ( A ) A M P A C I T Y C H E C K # 2 F E E D E R L E N G T H ( F E E T ) C O N D U C T O R R E S I S T A N C E ( O H M / K F T ) V O L T A G E D R O P A T F L A ( % ) C O N D U I T S I Z E C O N D U I T F I L L ( % ) STRING 1JUNCTION BOX 64010.6413.300 20N/ABARE COPPER #6AWGCU # 1 2 A W G 2 5 P A S S 3 4 2 3 0 0 . 9 6 0 1 2 8 . 8 0 0 P A S S 0 . 0 0 0 N / A # N / A STRING 2JUNCTION BOX 6407.989.975 20N/ABARE COPPER #6AWGCU # 1 2 A W G 2 5 P A S S 3 4 2 3 0 0 . 9 6 0 1 2 8 . 8 0 0 P A S S 0 . 0 0 0 N / A # N / A JUNCTION BOXLOAD CENTER 240 10.64 13.300 20N/ACU #10 AWG CU # 1 0 A W G 3 5 P A S S 3 4 2 4 0 0 . 9 6 0 1 3 8 . 4 0 0 P A S S 2 1 . 2 4 0 0 . 0 2 2 3 / 4 " E M T 1 1 . 8 7 6 2 LOAD CENTER AC DISCONNECT 240 18.62 23.275 40CU #8 AWGCU #8 AWG CU # 8 A W G 5 0 P A S S 3 4 2 5 5 0 . 9 6 0 1 5 2 . 8 0 0 P A S S 2 0 . 4 9 1 0 . 0 1 5 3 / 4 " E M T 3 8 . 0 4 8 8 AC DISCONNECT POI24018.6223.275 40CU #8 AWGCU #8 AWG CU # 8 A W G 5 0 P A S S 3 4 2 5 5 0 . 9 6 0 1 5 2 . 8 0 0 P A S S 2 0 . 4 9 1 0 . 0 1 5 3 / 4 " E M T 3 8 . 0 4 8 8 S t r i n g 1 V o l t a g e D r o p 0 . 0 5 2 S t r i n g 2 V o l t a g e D r o p 0 . 0 4 8 R E V S H E E T N A M E S H E E T S I Z E S H E E T N U M B E R STEVEN, DRESEN RESIDENCE 363 E SECOND SOUTH REXBURG, REXBURG, ID 83440 A N S I B 1 1 " X 1 7 " D A T E D E S C R I P T I O N R E V I S I O N S P R O J E C T N A M E & A D D R E S S D A T E : 0 7 / 2 7 / 2 0 2 3 D R A W N B Y P E R M I T S O L A R P L A T I N U M S O L A R . 9 5 3 W 7 0 0 N S U I T E 1 1 2 L O G A N , U T A H 8 4 3 2 1 U S A E m a i l : i n f o @ p l a t i n u m s o l a r . c o m . \ P l a t i n u m + S o l a r . p n g L A B E L S P V - 8 * * E L E C T R I C A L D I A G R A M S H O W N I S F O R L A B E L I N G P U R P O S E S O N L Y . N O T A N A C T U A L R E P R E S E N A T I O N O F E Q U I P M E N T A N D C O N N E C T I O N S T O B E I N S T A L L E D . L A B E L L O C A T I O N S P R E S E N T E D M A Y V E R Y D E P E N D I N G O N T Y P E O F I N T E R C O N N E C T I O N M E T H O D A N D L O C A T I O N P R E S E N T E D E L E C T R I C A L D I A G R A M P A G E . * * N O T E : CAUTION:AUTHORIZED SOLARPERSONNEL ONLY!LABEL LOCATION:AC DISCONNECTCODE REF: NEC 690.13(B)LABEL-1:TERMINALS ON THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION WARNING!ELECTRICAL SHOCK HAZARDLABEL LOCATION:AC DISCONNECTCOMBINERMAIN SERVICE PANELSUBPANELMAIN SERVICE DISCONNECTCODE REF: NEC 690.13(B)LABEL- 2:!WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION:PRODUCTION METERUTILITY METERMAIN SERVICE PANELSUBPANELCODE REF: NEC 705.12(D)(3) & NEC 690.59 LABEL- 3:TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANEL WARNING!LABEL LOCATION:MAIN SERVICE PANELSUBPANELMAIN SERVICE DISCONNECTCOMBINERCODE REF: NEC 110.27(C) & OSHA 1910.145 (f) (7)LABEL- 4:LABEL LOCATION:MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED)SUBPANEL (ONLY IF SOLAR IS BACK-FED)CODE REF: NEC 690.13 (F), NEC 705.12(B) (3-4) & NEC 690.59 LABEL- 5:CAUTION!PHOTOVOLTAIC SYSTEM CIRCUIT ISBACKFEEDLABEL LOCATION:MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED)SUBPANEL (ONLY IF SOLAR IS BACK-FED)CODE REF: NEC 705.12(B)(2)(c)LABEL- 6:SO L A R P V S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N TURN R A P I D S H U T D O W N S W I T C H T O T H E "OF F " P O S I T I O N T O SHUT D O W N P V S Y S T E M A N D R E D U C E S H O C K H A Z A R D I N T H E A R R A Y S O L A R E L E C T R I C P V P A N E L S LABEL L O C A T I O N : AC DI S C O N N E C T CODE R E F : I F C 6 0 5 . 1 1 . 3 . 1 ( 1 ) & N E C 6 9 0 . 5 6 ( C ) ( 1 ) ( a ) LABEL - 7 : R A P I D S H U T D O W N S W I T C H F O R S O L A R P V S Y S T E M LABEL L O C A T I O N : AC DI S C O N N E C T CODE R E F : N E C 6 9 0 . 1 3 ( B ) LABEL - 8 : LABEL L O C A T I O N : AC DI S C O N N E C T CODE R E F : N E C 6 9 0 . 1 3 ( B ) LABEL - 9 : LABEL - 1 0 : LABEL L O C A T I O N : MAIN S E R V I C E P A N E L SUBP A N E L AC DI S C O N N E C T CODE R E F : N E C 6 9 0 . 1 3 ( B ) P H O T O V O L T A I C A C D I S C O N N E C T NOMI N A L O P E R A T I N G A C V O L A T G E 2 4 0 V 1 8 . 6 2 A WARNINGPOWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICE !M A I N P H O T O V O L T A I C S Y S T E M D I S C O N N E C T LABEL L O C A T I O N : MAIN S E R V I C E D I S C O N N E C T ( O N L Y I F M A I N S E R V I C E D I S C O N N E C T I S P R E S E N T ) CODE R E F : N E C 6 9 0 . 1 3 ( B ) LABEL- 1 1 : LABEL - 1 2 : LABEL L O C A T I O N : PROD U C T I O N M E T E R ( O N L Y I F P R O D U C T I O N M E T E R I S U S E D ) CODE R E F : N E C 6 9 0 . 1 3 ( B ) M COMBINER A R R A Y A C A C P M 2 3 4 1 0 1 2 7 8 9 3 1 2 2 4 M S P / S U B P A N E L M S D SOLADECK / JUNCTION BOX 2 4 1 1 1 0 RATE D A C O U T P U T C U R R E N T U M J B A C M S P L C R E V S H E E T N A M E S H E E T S I Z E S H E E T N U M B E R STEVEN, DRESEN RESIDENCE 363 E SECOND SOUTH REXBURG, REXBURG, ID 83440 A N S I B 1 1 " X 1 7 " D A T E D E S C R I P T I O N R E V I S I O N S P R O J E C T N A M E & A D D R E S S D A T E : 0 7 / 2 7 / 2 0 2 3 D R A W N B Y P E R M I T S O L A R P L A T I N U M S O L A R . 9 5 3 W 7 0 0 N S U I T E 1 1 2 L O G A N , U T A H 8 4 3 2 1 U S A E m a i l : i n f o @ p l a t i n u m s o l a r . c o m . \ P l a t i n u m + S o l a r . p n g P L A C A R D POWER TO T H I S B U I L D I N G I S A L S O S U P P L I E D F R O M R O O F M O U N T E D SOLAR A R R A Y S W I T H S A F E T Y D I S C O N N E C T S A S S H O W N : C A U T I O N DIRECTORYPERMANENT PL A Q U E O R D I R E C T O R Y P R O V I D I N G T H E L O C A T I O N O F T H E SERVICE DISCO N N E C T I N G M E A N S A N D T H E P H O T O V O L T A I C S Y S T E M . (ALL PLAQUES A N D S I G N A G E W I L L B E I N S T A L L E D A S O U T L I N E D W I T H I N : NEC 690.56(B) & ( C ) , [ N E C 7 0 5 . 1 0 ] ) 363 E S E C O N D S O U T H R E X B U R G , R E X B U R G , I D 8 3 4 4 0 P V - 9 LABELING NOTES:1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETER M I N E E X A C T REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE A D J U S T M E N T S . 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 1 9 0 1 0 . 1 4 5 , A N S I Z 5 3 5 . 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 1 1 0 . 2 1 ] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, A N D P E R M A N E N T L Y AFFIXED [IFC 605.11.1.1]PV ARRA Y ( N ) L O A D C E N T E R (E) UTI L I T Y M E T E R ( N ) J U N C T I O N B O X (N) AC DI S C O N N E C T # 1 (E) MAIN SERV I C E PANEL (INSI D E ) R E V S H E E T N A M E S H E E T S I Z E S H E E T N U M B E R STEVEN, DRESEN RESIDENCE 363 E SECOND SOUTH REXBURG, REXBURG, ID 83440 A N S I B 1 1 " X 1 7 " D A T E D E S C R I P T I O N R E V I S I O N S P R O J E C T N A M E & A D D R E S S D A T E : 0 7 / 2 7 / 2 0 2 3 D R A W N B Y P E R M I T S O L A R P L A T I N U M S O L A R . 9 5 3 W 7 0 0 N S U I T E 1 1 2 L O G A N , U T A H 8 4 3 2 1 U S A E m a i l : i n f o @ p l a t i n u m s o l a r . c o m . \ P l a t i n u m + S o l a r . p n g M I C R O I N V E R T E R C H A R T 1-1023411-2021-30 31-40 41-50 5 1 - 6 0 5 6 1 - 7 0 678910 1 P V - 1 0