HomeMy WebLinkAboutCONCRETE FIELD TEST15 - 22-00269 - Hibbard Elementary SchoolFile name: 22229FB07262023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8036A710-3ACE-44DA-97E5-2ED564B26F09 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-229 Cumulative Test Load Amount: 10 Project Name: Hibbard Elementary Test Location: Curb, east side of building Client: Madison School District Admixtures: MP 322, MA AE 90 Ticket Number: 6558 Contractor: Richardsons Concrete Supplier: Walters Ready Mix, Inc. Mix Number: 500F HES Date: 7/19/2023 Cylinder Log #: 398 Field Test Results: Set #: 1 Entrained Air (%): 4.9 Concrete Temperature (°F): 77 Ambient Temperature (°F): 80 Unit Weight (PCF): 136.9 Tested By: Michael Hammar Time Tested: 09:07 AM Picked Up By: Jense Christensen Date: 7/20/2023 Time: 11:30 AM Max, Min Temperature 76,69 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 7/26/2023 4.000 12.57 61,885.0 4923 4,000.0 Type 3 Date: 07/26/2023 Reviewed By: Luke Hammar Signature: