HomeMy WebLinkAboutCONCRETE FIELD TEST15 - 22-00269 - Hibbard Elementary SchoolFile name:
22229FB07262023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8036A710-3ACE-44DA-97E5-2ED564B26F09 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-229
Cumulative Test Load Amount:
10
Project Name:
Hibbard Elementary
Test Location:
Curb, east side of building
Client:
Madison School District
Admixtures:
MP 322, MA AE 90
Ticket Number:
6558
Contractor:
Richardsons Concrete
Supplier:
Walters Ready Mix, Inc.
Mix Number:
500F HES
Date:
7/19/2023
Cylinder Log #:
398
Field Test Results:
Set #:
1
Entrained Air
(%):
4.9
Concrete
Temperature
(°F):
77
Ambient
Temperature
(°F):
80
Unit Weight
(PCF):
136.9
Tested By:
Michael Hammar
Time Tested:
09:07 AM
Picked Up By:
Jense Christensen
Date:
7/20/2023
Time:
11:30 AM
Max, Min Temperature
76,69
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 7/26/2023 4.000 12.57 61,885.0 4923 4,000.0 Type 3
Date:
07/26/2023
Reviewed By:
Luke Hammar
Signature: