HomeMy WebLinkAboutAPPROVED PLANS - 23-00329 - 545 Henderson St - Solar PanelsAuthor Name Author Email Author Phone No.: Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : 545 Henderson St - Solar Panels Address : 545 Henderson St Record Type : Solar Panels Document Filename : Kirkpatrick v1.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00329 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments PV0.0 Stamp Alex Owens : Electrical Open 1 Approved - Electrical Inspector E1.1 Free Text Alex Owens : Electrical Open 4 All electrical work to comply with 2017 NEC. E1.1 Stamp Alex Owens : Electrical Open 4 Approved - Electrical Inspector Solar Panels Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) N RevDescriptionDate REVISIONS Signature with Seal ANSI B 11" X 17" PV 0.0 SHEET INDEX: PV 0.0:COVER SHEET PV 1.0:SITE PLAN S 1.1: E 1.1:3-LINE DIAGRAM E 1.2: WIRE CALCULATION E 1.2:NOTES E 1.4:WARNING LABELS E 1.5:PLACARD DS:EQUIPMENT SPEC SHEET COVER SHEET MOUNT DETAILS 2 SATELLITE VIEW PV 0.0 3 VICINITY MAP PV 0.0 1 PLOT PLAN PV 0.0 GENERAL NOTES: a.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. b.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. c.ALL CONDUCTORS,INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250. d.ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] e.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] f.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. g.PV MODULES TO BE RATED UL 1703 CLASS A FIRE RATING OR BETTER. h.ALL EQUIPMENT TO BE CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. PROTECTION OF EMERGENCY RESPONDERS ALL SHARP EDGES AND FASTENER TIPS SHALL BE COVERED OR CRIMPED OVER TO ELIMINATE SHARP EDGES, TO MINIMIZE RISK OF INJURY TO EMERGENCY RESPONDERS. ALL ROOF MOUNTED CONDUITS, BOXES, AND EQUIPMENT CROSSING PATHWAYS ARE TO BE CLEARLY IDENTIFIED BY A RED/WHITE REFLECTIVE TAPE OR OTHER APPROVED MATERIAL. ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. SYSTEM SIZE: MODULE TYPE & AMOUNT: MODULE DIMENSIONS: INVERTER: INTERCONNECTION METHOD: PHOTOVOLTAIC SYSTEM SPECIFICATIONS: PHOTOVOLTAIC ROOF MOUNT SYSTEM 16 MODULES ROOF MOUNTED (LAT. 43.82°, LONG. -111.80°) GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES ED K I R K P A T R I C K 54 5 H E N D E R S O N S T RE X B U R G I D , 8 3 4 4 0 AP N : R P R H N D S 0 0 2 0 0 2 0 545 HENDERSON ST REXBURG ID, 834405.60 kW DC 15.00 kW AC (16) LG350Q1C-A5 (L/W) 67.8"X 44.65" (1) SOL-ARK 15K-2P BACKFED kW AC kW DC5.60 15.00 85 9 S . Y E L L O W S T O N E H W Y UN I T 3 0 5 RE X B U R G , I D A H O , 8 3 4 4 0 (8 8 8 ) 4 6 8 - 7 1 8 0 FR O N T O F H O U S E 54 5 H E N D E R S O N S T 2017 NATIONAL ELECTRICAL CODE (NEC) 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL PRESIDENTIAL CODE (IRC) 2018 INTERNATIONAL FIRE CODE (IFC) 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) EXISTING INTERIOR MAIN SERVICE PANEL & POINT OF INTERCONNECTION, TIED TO EXTERIOR UTILITY METER 85041423 BAT NEW PV AC DISCONNECT GROUPED WITH SERVICE EQUIPMENT (VISIBLE,LOCKABLE, LABELED) INVERTER SOLARK 15K-2P-K HOMEGRID STACK'D 14.4KW BATTERY (3 BATTERY CELLS) (E)(16) LG350Q1C-A5 (E)(16) P370 SOLAR EDGE OPTIMIZER SLOPE - 37° AZIMUTH -180° ROOF #1 N Description Date Rev REVISIONS Signature with Seal ANSI B 11" X 17" PV 1.0 EQUIPMENT LAYOUT & SITE PLAN ROOF SECTION(S) 1 SITE PLAN PV 1.0 ADDITIONAL NOTES: FINAL LOCATION OF ALL CONDUIT AND JUNCTION BOXES TO BE DETERMINED AT TIME OF INSTALLATION. CONDUIT TO BE PAINTED TO MATCH EXTERIOR OF RESIDENCE WHERE APPLICABLE AND IS TO BE SUPPORTED EVERY 10' MAX. 30" WIDE X 36" DEEP WORKING SPACE CLEARANCES REQUIRED ABOUT ALL ELECTRICAL EQUIPMENT. STAGGER PENETRATIONS TO EVENLY DISTRIBUTE LOAD ACROSS ALL TRUSSES UNDER ARRAY. ALL DIMENSIONS ARE APPROXIMATIONS. MODULE - (E)16 LG350Q1C-A5 SLOPE - 37° AZIMUTH - 180° MATERIAL - ASPHALT SHINGLED ROOF #01 SYSTEM LEGEND EXISTING EXTERIOR MAIN SERVICE PANEL & POINT OF INTERCONNECTION. TIED TO EXTERIOR UTILITY METER 85041423 NEW PHOTOVOLTAIC UTILITY DISCONNECT SWITCH. LOCATED WITHIN 10' OF MSP. NEW DEDICATED PV SYSTEM COMBINER PANEL. M CB 16 NEW LG350Q1C-A5 MODULE WITH NEW 1 SOL-ARK 15K-2P INVERTERS, MOUNTED ON THE BACK OF EACH MODULES. = ATTACHMENT POINTS = RAFTER = ROOF OBSTRUCTIONS = RACKING SYSTEM = ATTIC RUN = CONDUIT ATTIC RUN JUNCTION BOX SYSTEM SIZE: MODULE TYPE & AMOUNT: MODULE DIMENSIONS: INVERTER: INTERCONNECTION METHOD: PHOTOVOLTAIC SYSTEM SPECIFICATIONS: ED K I R K P A T R I C K 54 5 H E N D E R S O N S T RE X B U R G I D , 8 3 4 4 0 AP N : R P R H N D S 0 0 2 0 0 2 0 (16) LG350Q1C-A5 (L/W) 67.8"X 44.65" (1) SOL-ARK 15K-2P BACKFED kW AC kW DC5.60 15.00 MODULE ARRAY WEIGHT (LOAD CALC'S) NUMBER OF MODUELS 16 MODULE WEIGHT 47.39 LBS TOTAL MODULE (ARRAY) WEIGHT 758.24 LBS MODULE AREA 20.98 SQFT TOTAL ARRAY AREA 335.68 SQFT TOTAL ROOF AREA 1376.36 SQFT TOTAL PERCENTAGE OF ROOF COVERED 24% RAFTER SIZE & SPACING - 2"X4" TRUSSES @24" O.C 85 9 S . Y E L L O W S T O N E H W Y UN I T 3 0 5 RE X B U R G , I D A H O , 8 3 4 4 0 (8 8 8 ) 4 6 8 - 7 1 8 0 EXISTING INTERIOR MAIN SERVICE PANEL & POINT OF INTERCONNECTION, TIED TO EXTERIOR UTILITY METER 85041423 NEW PV AC DISCONNECT GROUPED WITH SERVICE EQUIPMENT (VISIBLE,LOCKABLE, LABELED) HOMEGRID STACK'D 14.4KW BATTERY (3 BATTERY CELLS) ROOF #01 Description Date Rev REVISIONS Signature with Seal ANSI B 11" X 17" S 1.1 MOUNT DETAIL 2 ATTACHMENT DETAIL ENLARGED VIEW S 1.1 NOTE: - CONTRACTOR/INSTALLER TO VERIFY COMPATIBILITY OF ANY BRANDS OR PRODUCTS SUBSTITUTED OR USED AS ALTERNATES WITHIN ANY BRAND-SPECIFIC SYSTEMS. CONTRACTOR SHALL SUPPLY AND PRESENT CERTIFICATES OF COMPATIBILITY TO THE BUILDING OFFICIAL UPON INSPECTION. GENERAL STRUCTURAL NOTES: 1 ATTACHMENT DETAIL (SIDE VIEW) S 1.1 1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE PEGASUS RACKING SYSTEM WITH BRACKET ATTACHMENTS. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.THE PROPOSED PV SYSTEM ADDS 1.3 PSF TO THE ROOF FRAMING SYSTEM 3.ROOF LIVE LOAD = 0 PSF TYPICAL, 1.3 PSF UNDER NEW PV SYSTEM 4.GROUND SNOW LOAD = 36 PSF 5.WIND SPEED = 102 MPH 6.EXPOSURE CATEGORY = C 7.RISK CATEGORY = II ED K I R K P A T R I C K 54 5 H E N D E R S O N S T RE X B U R G I D , 8 3 4 4 0 AP N : R P R H N D S 0 0 2 0 0 2 0 85 9 S . Y E L L O W S T O N E H W Y UN I T 3 0 5 RE X B U R G , I D A H O , 8 3 4 4 0 (8 8 8 ) 4 6 8 - 7 1 8 0 NOTE: - 1.AS PER THE 314.16(A) SOLADECK JUNCTION BOX SIZE SHOULD BE 3" X 2" X 2". 2.300.15(F) FITTING. A FITTING IDENTIFIED FOR THE USE SHALL BE PERMITTED IN LIEU OF A BOX OR CONDUIT BODY WHERE CONDUCTORS ARE NOT SPLICED OR TERMINATED WITHIN THE FITTING. THE FITTING SHALL BE ACCESSIBLE AFTER INSTALLATION, UNLESS LISTED FOR CONCEALED INSTALLATION. 3.FROM FREE AIR WIRING METHODS TRANSITIONING TO A RACEWAY WIRING METHOD SHALL COMPLY WITH NEC 300.15, 300.17, 314.16 AND 69.43 AS APPLICABLE NOTE: - #6 AWG SOLID CU EQUIPMENT GROUND CONDUCTOR CONT. RUN TO GROUND LUG ON RACKING SYSTEM. ALL ROOFTOP COMPONENTS BONDED TO RACKING SYSTEM PER NEC 690.43 NOTE: - 1.PV WIRE - GREEN SPEC, UL SUBJECT 4703, UL 44, UL 854, 200V, 90C-RoHS 2.JUNCTION BOX - SOLADECK (0799-5), UL 50, CSA C22.2 NO # 290, NEMA TYPE 3R, UL 1741 NOTES: 1. CONDUCTORS ON ROOF MUST BE SUNLIGHT RESISTANT, 90°C RATED AND SUITABLE FOR WET LOCATIONS. 2. SEE RACKING SPEC SHEETS FOR RACKING EQUIPMENT GROUNDING METHOD. 3.ALL GROUNDING CONDUCTORS MUST BE PROTECTED FROM DAMAGE IF NOT INSTALLED IN CONDUIT. 4. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF. 5. ALL DEVICES USED FOR BONDING FRAMES OF MODULES OR OTHER EQUIPMENT TO THE GROUNDING SYSTEM MUST BE LISTED AND IDENTIFIED FOR THE PURPOSE. 6. OPTIMIZERS ARE TO BE BONDED TO RACKING BY USING EITHER AN OPTIMIZER ATTACHMENT KIT OR A GROUNDING PLATE. NOTE: SOLADECK JUNCTION BOX IS UL50 TYPE 3R AND NEMA TYPE 3R RATED, CONFORMING TO UL 1741. SOLADECK PRODUCTS ARE LISTED BY ETL TO UL STANDARDS (SEE SPEC SHEETS). NOTE THAT 8*3/4" = 6" < 8", SO OK TO USE. Description Date Rev REVISIONS Signature with Seal ANSI B 11" X 17" E 1.1 3-LINE DIAGRAM PV MODULE FRAME PEGASUS RAIL UNIVERSAL FASTENING OBJECT GROUNDING PIERCES THROUGH ANODIZED COATINGS OF MODULE FRAMES AND RAILS GROUNDING DETAIL PEGASUS INTEGRATED GROUNDING & LAY-IN LUGS ARE UL2703 LISTED #10-24 X 3/4" SS HCS BOLT SS SET SCREW INCLUDED #10 SS EXTERNAL TOOTH LOCK (STAR) WASHER #10-24 SS LOCK NUT 8 AWG BARE CU WIRE LAY-IN LUG TERMINAL AL/CU DUAL RATED (TIN PLATED CU) PEGASUS RAIL RAILS MODULES SYSTEM SIZE: 5.60 kW DC 15.00 kW AC MODULE:(E)(16) LG350Q1C-A5 INVERTER:(1) SOL-ARK 15K-2P MANUFACTURE'S DOCUMENTATION:- 1.PV WIRE - GREEN SPEC, UL SUBJECT 4703,UL 44, UL 854,2000V, 90C-RoHS 2.JUNCTION BOX -SOLARDECK (0799-5),UL 50CSA C22.2 NO#290, NEAM TYPE 3R, UL 1741 SERVICE FEED SOURCE: PACIFIC POWER 240V SQUARE-D SERVICE INFO. SOUTHWEST UNDERGROUND (E) 200A (E) 200A 120% Rule (BUS BAR RATING X 120%) - MAIN BREAKER RATING = MAX PV OCPD (200A x 120%) - 200 = 40A ED K I R K P A T R I C K 54 5 H E N D E R S O N S T RE X B U R G I D , 8 3 4 4 0 AP N : R P R H N D S 0 0 2 0 0 2 0 85 9 S . Y E L L O W S T O N E H W Y UN I T 3 0 5 RE X B U R G , I D A H O , 8 3 4 4 0 (8 8 8 ) 4 6 8 - 7 1 8 0 02 STRINGS OF 08 MODULES CONNECTED IN SERIES L BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz (3)#4/0 AWG ALUM T 2" EMT OR EQUIVALENT CONDUIT G 200A FUSES (1)#6 AWG ALU THWN 2" EMT OR EQUIVALENT CONDUIT (N) AC DISCONNECT 200A FUSED, VISIBLE LOCKABLE LABELED, 200A FUSES, 240 VAC (N) MAIN BREAKER 200A/2P, 240V (3)#4/0 AWG ALU T 200A #8 #2 #1 #8 #2 #1 8 MODULES IN STRING #1 8 MODULES IN STRING #2 G (N)SOL-ARK-15K-P INVERTER DC AC Gen In AC In/Out Load Out PV Input DC Input (2) #10 AWG PV WIRE + RED (1) #6 BARE CU GND 3/4" EMT CONDUIT (1) #8 AWG THWN-2 + RED (1)#8 AWG THWN-2 - BLACK (1)#8 AWG THWN-2 - WHITE (1) #8 THWN-2 GND (N) JUNCTION BOX 600 V, NEMA 3 UL LISTED 3/4 " EMT / LT (3)#12 AWG COPPER MASTER INVERTER TIGO TS4-A-F RAPID SHUTDOWN DEVICES BATTERY DISCONNECT RAPID SHUTDOWN BUTTON WILL BE LOCATED NEXT TO THE SOL-ARK INVERTER. TIGO TRANSMITTER 200A BREAKER EXISTING GROUNDING SYSTEM #6 AWG COPPER GND NEW GROUNDING LUG HOMEGRID STACK'D 14.4 KWH BATTERY (3 BATTERY CELLS) 4.8 KWh 4.8 KWh 4.8 KWh BMS BATTERY CABLE (2) SCE #2/0 AWG COPPER CABLE CLASS K 600 V PER NEC 400.4 (N) MAIN SERVICE PANEL, 200A RATED, 120/240V (3) #4/0 AWG ALU THWN (1) #2 AWG ALU THWN GND 2" EMT OR EQUIVALENT CONDUIT - ~ (E) SOLAR EDGE SE7600A-US All electrical work to comply with 2017 NEC. Description Date Rev REVISIONS Signature with Seal ANSI B 11" X 17" E 1.2 NOTES SITE NOTES: 1.A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 3.THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 4.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 5.ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. EQUIPMENT LOCATIONS: 1.ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 2.WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C). 3.JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. 4.ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 5.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. STRUCTURAL NOTES: 1.RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY / SUBARRAY, ACCORDING TO RAI MANUFACTURER’S INSTRUCTIONS. 2.JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 3.ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 4.ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. WIRING & CONDUIT NOTES: 1.ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. 3.VOLTAGE DROP LIMITED TO 1.5%. 4.DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 5.AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15]. GROUNDING NOTES: 1.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122. 3.METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 4.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND MICRO INVERTER MANUFACTURERS’ INSTRUCTIONS. 5.EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. 6.THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 7.GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119] 8.THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ. 9.GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 1.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 2.DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 3.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D). 4.ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. 5.MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B). 6.IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. INTERCONNECTION NOTES: 1.LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705.12 (B)] 2.THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF BUS BAR RATING [NEC 705.12(D)(2)(3)]. 3.THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUS BAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUS BAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)]. 4.AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12 (B)(2)(3)(C). 5.FEEDER TAP INTERCONNECTION (LOADSIDE) ACCORDING TO NEC 705.12 (B)(2)(1) 6.SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [NEC 705.12 (B)(5)]. PV MODULE RATING @ STC MANUFACTURER MAX. POWER-POINT CURRENT (IMP) MAX. POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) 10.74 AMPS 41.00 VOLTS 49.60 VOLTS 11.34 AMPS NOM. MAX. POWER AT STC (PMAX) MAX. SYSTEM VOLTAGE VOC TEMPERATURE COEFFICIENT 440 WATT 1000V -0.27° %/°C LG350Q1C-A5 Rooftop conductor ampacities designed in compliance with art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9. Location specific temperature obtained from ASHRAE 2017 data tables AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP -16°C 34°C CONDUIT HEIGHT 0.5" ROOF TOP TEMP 56°C CONDUCTOR TEMPERATURE RATE 90°C INVERTER SPECIFICATIONS MANUFACTURER MAX. POWER AT 40 C 58 VOLTS NOMINAL AC VOLTAGE 349 WATTS MAX. AC CURRENT 240 VOLTS MAX. OCPD RATING MAX. PANELS/CIRCUIT SHORT CIRCUIT CURRENT 1.45 AMPS 20 AMPS MAX. DC VOLT RATING 11 15 AMPS SOL-ARK 15K-2P ED K I R K P A T R I C K 54 5 H E N D E R S O N S T RE X B U R G I D , 8 3 4 4 0 AP N : R P R H N D S 0 0 2 0 0 2 0 85 9 S . Y E L L O W S T O N E H W Y UN I T 3 0 5 RE X B U R G , I D A H O , 8 3 4 4 0 (8 8 8 ) 4 6 8 - 7 1 8 0 Description Date Rev REVISIONS Signature with Seal ANSI B 11" X 17" E 1.3 WARNING LABELS ELECTRICAL NOTES: 1. ALL PV MODULES, ARRAY FRAMING AND RACKING SHALL BE GROUNDED PER MFR'S SPECIFICATIONS. 2. ALL EQUIPMENT WILL BE UL 1703, UL 1741, OR UL 2703 LISTED AND CERTIFIED. 3. MODULES WILL BE GROUNDED WITH INTEGRADED GROUNDING MODULE CLAMPS. ARRAY FRAME WILL BE GROUNDED WITH ILSCO GBL-4DBT (OR EQUIVALENT - SUITABLE FOR DIRECT BURIAL AND CONTACT WITH COPPER OR ALUMINUM) LAY IN TYPE GROUNDING LUG. USE SPECIFIED MODULE GROUNDING POINTS. 4. ALL WIRE TERMINATIONS, SPLICES AND CONNECTIONS SHALL BE MADE USING A LISTED DEVICE OR ELECTRICAL BOX SUITED FOR THE PURPOSE. ALL WIRES NOT IN CONDUIT TO BE PROVIDED WITH STRAIN RELIEF AT ENTRY INTO JUNCTION BOXES. 5. PROVIDE AND INSTALL CONDUIT EXPANSION FITTINGS, PER MANUFACTURER'S SPECIFICATIONS, IN CONDUIT RUNS WHERE THERMAL EXPANSION IS 0.25" OR MORE, BASED ON RECORD MAXIMUM AND MINIMUM TEMPERATURES FOR THE SITE (SEE NEC TABLE 310.15(B)(2)(C), AND USING EXPANSION COEFFICIENT OF STEEL. 6. BOTH ENDS OF ALL METALLIC CONDUIT CONTAINING GROUNDING ELECTRODE CONDUCTORS SHALL BE BONDED PER NEC 250.64(E). 7. PROVIDE AND INSTALL ALL GROUNDING AS REQUIRED BY NEC ARTICLES 250, 690 AND SYSTEM MANUFACTURER. 8. INSTALLATIONS WHICH USE TRANSFORMER-LESS INVERTERS - PV WIRE TYPE IS REQUIRED FOR ALL DC WIRE RUNS IN FREE AIR, OR NOT IN CONDUIT. 9. EACH CURRENT CARRYING CONDUCTOR IN ALL PV SOURCE CIRCUITS OR PV OUTPUT CIRCUITS SHALL BE DISCONNECTED/ FUSED, WHEN NECESSARY. 10. CONTRACTOR SHALL VERIFY EXISTENCE OF UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATIONS. 11. ELECTRICAL TRENCH RUNS, WHERE USED, SHALL USE SCHEDULE 40 PVC CONDUIT AND PROVIDE 18" MIN CLEARANCE FROM TOP OF CONDUIT TO GRADE, AND MAGNETIC WARNING TAPE AT 12" BELOW GRADE. 24" CLEARANCE AND SCHEDULE 80 PVC IS REQUIRED IN AREAS WHERE SUBJECT TO VEHICLE TRAFFIC. 12. CHECK WITH LOCAL JURISDICTION FOR ANY ADDITIONAL FILL AND COMPACTION REQUIREMENTS, SPOILS TREATMENT AND/OR EROSION CONTROL MEASURES PRIOR TO EXCAVATION. 13. INSTALLATIONS IN LIGHTENING-PRONE LOCATIONS ARE RECOMMENDED TO UTILIZE DC LIGHTENING ARRESTORS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 14. SUPPLY SIDE CONNECTIONS SHALL ONLY BE MADE WITH LISTED AND APPROVED TAPS. 15. ALL WIRE RUNS SHALL NOT EXCEED 2% CALCULATED VOLTAGE DROP. 16. VERIFY EXISTING GROUNDING ELECTRODE. IF NONE EXISTS, A NEW GROUND ROD MAY BE REQUIRED. MIN. SIZE 8' LONG X 5/8" DIA, COPPER CLAD. BOND TO GAS, AND HOT AND COLD WATER PIPES. 17. USE WATERPROOF FITTINGS FOR ALL EXTERIOR CONDUIT. 18. GROUNDING ELECTRODE CONDUCTOR (AC SIDE OF INVERTER) IS #8 IF IN CONDUIT, OR #6 AWG IF EXPOSED AND SUBJECT TO DAMAGE, AND SHALL BE CONTINUOUS FROM INVERTER TO GROUND ROD. USE IRREVERSIBLE SPLICES WHERE NECESSARY. 19. EQUIPMENT GROUNDING CONDUCTOR (DC SIDE OF INVERTER) IS #10 IF IN CONDUIT, OR #6 AWG IF EXPOSED AND SUBJECT TO DAMAGE (NEC 690.46). SIGNAGE NOTES: 1. SIGNAGE SHALL BE PERMANENTLY AFFIXED TO EQUIPMENT WITH POP-RIVETS, SCREWS OR APPROVED ADHESIVE. 2. OUTDOOR SIGNAGE SHALL BE UV STABLE AND SUITABLE FOR ITS ENVIRONMENT. CONDUIT STICKERS SHALL BE SHALL BE REFLECTIVE. 3. PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PHOTO PLATING, SHALL HAVE RED BACKGROUND WITH WHITE LETTERING. MINIMUM FONT SIZE SHALL BE 3/8" HEIGHT AND ALL CAPITAL LETTERS. 4. DEVICES MARKED WITH "LINE" AND "LOAD" ARE NOT SUITABLE FOR FOR BACKFEED OR REVERSE CURRENT. 5. SIGNAGE CANNOT BE HAND WRITTEN. 6. NET METER BASE, PRODUCTION METER BASE, AND SOLAR AC DISCONNECT ENGRAVED LABELS MUST BE MECHANICALLY FASTENED WITH RIVETS, SCREWS, OR BOLTS. A SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS LABEL LOCATION: MAIN SERVICE DISCONNECT PER CODE: NEC 690.56(C)(1)(a) LABEL LOCATION: EMT, CONDUIT RACEWAY, CABLE TRAYS PER CODE: NEC 690.31(G)(3-4) LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 690.54 PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 30.45 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS ELECTRICAL SHOCK HAZARD ! WARNING LABEL LOCATION: COMBINER PANEL, AC DISCONNECT, POINT OF INTERCONNECTION PER CODE(S): NEC 690.13(B) DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: MAIN SERVICE DISCONNECT PER CODE: NEC 705.12(B)(3-4), NEC 690.59 LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METER PER CODE: NEC 690.13(B) POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. ! WARNING LABEL LOCATION: MAIN SERVICE DISCONNECT, POINT OF INTERCONNECTION PER CODE: 705.12(B)(2)(3)(b) ! WARNING LABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECT PER CODE(S): NEC 110.27(C), OSHA 1910.145(f)(7) LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.13(B) DO NOT DISCONNECT UNDER LOAD LABEL LOCATION: MAIN SERVICE DISCONNECT PER CODE: NEC 690.15(C) & NEC 690.33(E)(2) LABEL LOCATION: RSD INITIATION DEVICE, AC DISCONNECT PER CODE: NEC 690.56(C)(3) PV SYSTEM DISCONNECT THIS EQUIPMENT FED BY MULTIPLE SOURCES, TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. ! WARNING LABEL LOCATION: POINT OF INTERCONNECTION, COMBINER PANEL PER CODE: NEC 705.12(B)(2)(3)(c) WARNING! ED K I R K P A T R I C K 54 5 H E N D E R S O N S T RE X B U R G I D , 8 3 4 4 0 AP N : R P R H N D S 0 0 2 0 0 2 0 85 9 S . Y E L L O W S T O N E H W Y UN I T 3 0 5 RE X B U R G , I D A H O , 8 3 4 4 0 (8 8 8 ) 4 6 8 - 7 1 8 0