Loading...
HomeMy WebLinkAboutAPPROVED PE LETTER - 23-00305 - 366 Oaktrail Dr - Solar PanelsAuthor Name Author Email Author Phone No.: Larry Beesley Larry.Beesley@rexburg.org 208-372-2176 Description : 366 Oaktrail Dr - Solar Panels Address : 366 Oaktrail Dr Record Type : Solar Panels Document Filename : Alan Christensen - PE Letter.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00305 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments 1 Stamp Larry Beesley : Building Open 1 Approved - Building Inspector Solar Panels Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Freedom Forever LLC 43445 Business Park Dr., STE 110 Temecula, CA, 92590 Subject: Structural Certification for Installation of Solar Panels Job Number: 23-06002 Client: ALAN CHRISTENSEN - 013878 Address: 366 OAKTRAIL DRIVE,, REXBURG, ID 83440 Attn.: To Whom It May Concern A field observation of the condition of the existing framing system was performed by an audit team from Freedom Forever LLC. From the field observation of the property, the existing roof structure was observed as follows: The existing roof structure consists of: ● Design Criteria: ●Applicable Codes = 2018 IBC, 2018 IEBC, ASCE 7-16, and NDS-18 ●Ground Snow Load = 50 psf; Roof Snow Load = 34.7 psf ARRAY 1 ●Roof Dead Load = 6.6 psf ARRAY 1 ●Basic Wind Speed = 115 mph Exposure Category C As a result of the completed field observation and design checks: ● If you have any questions on the above, do not hesitate to call. Prepared By: PZSE, Inc. - Structural Engineers Roseville, CA ARRAY 1: is adequate to support the loading imposed by the installation of solar panels and modules. Therefore, no structural upgrades are required. I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to meet or exceed the requirements without structural upgrade in accordance with the 2018 IBC. May 19, 2023 Composition Shingle over Roof Plywood is supported by 2x4 @ 24"o.c. SPF#2 at ARRAY 1. The top chords are sloped at approximately 25 degree and have a maximum projected horizontal span of 6 ft 2 in between load bearing supports. 366 OAKTRAIL DRIVE, REXBURG, ID 83440 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience | Integrity | Empowerment Paul Zacher Digitally signed by Paul Zacher Date: 2023.05.19 15:02:21-07'00'