Loading...
HomeMy WebLinkAboutPLANS - 23-00456 - MMH Behavioral Health TI - Remodel#.#GRID/LEVEL HEAD WALL TYPE TAG WINDOW TAG DOOR TAG ROOM NAME #####ROOM TAG WALL SECTION BUILDING SECTIONKEYNOTE TAG VIEW TITLE REFERENCE TAG SECTION # SECTION # VIEW # OR LETTER SHEET # A#.## 1 SIM DETAIL OR ENLARGED PLAN CALLOUTACCESSORY TAG SHEET # SHEET # NORTH ARROW VIEW # A#.## 1 INTERIOR ELEVATION LEVEL NAME / ELEVATION MARKER 1 View Name 1/8" = 1'-0"A101 0 2' 4' 8' GRAPHIC SCALE ###M 36" 36" 16" Extra Shelf CASEWORK TAG 1 A101 1 A1.01SHEET # VIEW # OR LETTER SHEET # ## X LEVEL 0' -0" 1 A101 BUILDING ELEVATION VIEW # OR LETTER SHEET # N XXXXXXX XXX XXXx #####.A O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP: PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com DRAWING INDEX: PIVOT NORTH ARCHITECTURE PROJECT #: VICINITY MAP: 7/ 1 3 / 2 0 2 3 1 : 3 1 : 2 3 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 COVER SHEET 23-010 AMM TB 07/13/2023 G0.00 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 MMH Behavioral Health TI 37 S 2ND STREET EAST, REXBURG, IDAHO 83440 07/13/2023 23-010 [LOGO][STAMP PHONE: FAX: CONTACT: E-MAIL: MOBILE: INTERNET: OWNER MADISON MEMORIAL HOSPITAL 450 E MAIN ST, OFFICE 4503 REXBURG, IDAHO 83440 208.432.2494 AMOS KINGTON N/A amos.kington@mmhnet.org 208.432.2494 madisonmemorial.org [LOGO] [STAMP PHONE: FAX: CONTACT: E-MAIL: MOBILE: INTERNET: ARCHITECT PIVOT NORTH ARCHITECTURE 1101 W. GROVE STREET BOISE, IDAHO 83702 208.690.3108 GARY SORENSEN N/A gary@pivotnorthdesign.com N/A www.pivotnorthdesign.com [LOGO] [STAMP PHONE: FAX: CONTACT: E-MAIL: MOBILE: INTERNET: MECHANICAL ENGINEER MUSGROVE ENGINEERING, P.A. 234 S WHISPERWOOD WAY BOISE, DAHO 83709 208.384.0585 DUSTIN MILLER N/A dustinm@musgrovepa.com N/A www.musgrovepa.com [LOGO] [STAMP PHONE: FAX: CONTACT: E-MAIL: MOBILE: INTERNET: ELECTRICAL ENGINEER MUSGROVE ENGINEERING, P.A. 234 S WHISPERWOOD WAY BOISE, IDAHO 83709 208.532.2862 MATTHEW BRADLEY N/A mattb@musgrovepa.com N/A www.musgrovepa.com INTERNATIONAL PLUMBING CODE NATIONAL ELECTRICAL CODE ZONING ORDINANCE: INTERNATIONAL MECHANICAL CODE INTERNATIONAL FIRE CODE INTERNATIONAL ENERGY CONSERVATION CODE INTERNATIONAL BUILDING CODE ACCESSIBILITY CODE APPLICABLE CODES OTHER CRITERIA DEFERRED SUBMITTALS INTERNATIONAL EXISTING BUILDING CODE 2018 ICC/ANSI A117.1/ IBC CODE 2018 EDITION 2018 EDITION 2018 EDITION 2018 EDITION 2017 IDAHO STATE PLUMBING CODE 2017 EDITION Zoning OrdinanceREXBURG FIRE ALARM GENERAL G0.00 COVER SHEET G0.02 ACCESSIBILITY COMPLIANCE G0.03 CODE COMPLIANCE, EXITING AND OCCUPANCY, WALL TYPES AND DETAILS ARCHITECTURAL A2.01 LEVEL 1 - COMPOSITE FLOOR PLAN A2.11 LEVEL 1 - DEMO AND AREA FLOOR AND CEILING PLANS A7.01 DOOR SCHEDULE & TYPES, FINISHES, INTERIOR ELEVATIONS ABBREVIATIONS: #NUMBER OR POUND ø DIAMETER ANGLE @ AT &AND CL CENTERLINE AB ANCHOR BOLT ACT ACOUSTICAL CEILING TILE ADJ ADJUSTABLE AED AUTOMATED EXTERNAL DEFIBRILLATOR AFF ABOVE FINISH FLOOR ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE ASSOC ASSOCIATED BD BOARD BFC BROOM FINISH CONCRETE BLDG BUILDING BLKG BLOCKING BM BEAM BO BOTTOM OF BOT BOTTOM BRG BEARING BSMT BASEMENT BTWN BETWEEN CAB CABINET CPT CARPET C.I.P.CAST-IN-PLACE CJ CONTROL JOINT CL CENTERLINE CLG CEILING CMU CONCRETE MASONRY UNITS CO CLEAN OUT COL COLUMN CONC CONCRETE CONST CONSTRUCT CONT CONTINUOUS CSK COUNTERSINK CMT CERAMIC MOSAIC TILE CQT CERAMIC QUARRY TILE CWB CERAMIC WALL BASE DBL DOUBLE DEPT DEPARTMENT DT DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DS DOWNSPOUT EA EACH EBT EXPANSION BASE TRIM EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATION EP EPOXY PAINT EQ EQUAL EQUIP EQUIPMENT ESTR EXPOSED STRUCTURE (NEW OR EXISTING) EIFS EXTERIOR INSULATION & FINISH SYSTEM EXIST EXISTING EXP EXPANSION EXT EXTERIOR FD FLOOR DRAIN F.D.C.FIRE DEPARTMENT CONNECTION FB FIRE BLANKET FE FIRE EXTINGUISHER F.E.C.FIRE EXTINGUISHER CABINET FF FACTORY FINISH F.H.FIRE HYDRANT FIN FINISH FL FLOOR LINE FLR FLOOR FND FOUNDATION FOC FACE OF CHANNEL FOF FACE OF FINISH FOS FACE OF STUDS FT FEET FTG FOOTING FV FIELD VERIFY GA GAUGE GALV GALVANIZED GB GYPSUM BOARD GYP.BD.GYPSUM BOARD HAS HEAD ANCHOR STUD HCW HOLLOW CORE WOOD HM HOLLOW METAL HORIZ HORIZONTAL HT HEIGHT HW HARDWOOD ID INSIDE DIAMETER INSUL INSULATION INT INTERIOR INV INVERT JAN JANITOR JST JOIST JT JOINT LAB LABORATORY LAM LAMINATE LAV LAVATORY MAT MATERIAL MAX MAXIMUM MECH MECHANICAL MET METAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS ML MEASURING LINE MO MASONRY OPENING MTD MOUNTED MTG MOUNTING NA NOT APPLICABLE NB NO BASE (EXPOSED WALL OR FOUNDATION) NC NEW CONCRETE NIC NOT IN CONTRACT NM NEW MASONRY NO NUMBER NOM NOMINAL NTS NOT TO SCALE SYMBOLS: OC ON CENTER OD OUTSIDE DIAMETER OFF OFFICE OFCI OWNER FURNISHED/CONTRACTOR INSTALLED OFOI OWNER FURNISHED/OWNER INSTALLED OPNG OPENING OTA OPEN TO ABOVE OTS OPEN TO STRUCTURE OVF OVERFLOW PC PAINT COLOR P.I.V. POST INDICATOR VALVE PLAST PLASTIC PLYWD PLYWOOD PR PAIR R THERMAL RESISTANCE RCP REFLECTED CEILING PLAN RD ROOF DRAIN RDL RAIN DRAIN LEADER RE:REFERENCE REFRIG REFRIGERATOR REINF REINFORCING REQ REQUIRED RF EPOXY FLOOR SYSTEM RM ROOM RO ROUGH OPENING RST RUBBER STAIR TREADS RWB RUBBER WALL BASE RWC RAIN WATER CONDUCTOR SC SEALED CONCRETE SCHED SCHEDULE SCW SOLID CORE WOOD SGWB SUSPENDED GYPSUM WALL BOARD SHT SHEET SHTG SHEATHING SIM SIMILAR SPECS SPECIFICATIONS SQ SQUARE SS STAINLESS STEEL STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SV SHEET VINYL TEMP TEMPORARY TO TOP OF TOM TOP OF MASONRY TS TUBE STEEL TYP TYPICAL UON UNLESS OTHERWISE NOTED VAR VARIES VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE W/WITH WC WATER CLOSET WD WOOD WF WALL FABRIC WH WATER HEATER WM WALK-OFF MAT W/O WITH OUT WP WATERPROOF WRGB WATER RESISTANT GYPSUM BOARD WT WEIGHT WWF WELDED WIRE FABRIC MECHANICAL M0.00 MECHANICAL COVER SHEET M0.01 MECHANICAL SPECIFICATIONS M1.00 MECHANICAL PLANS M2.00 MECHANICAL DETAILS M3.00 MECHANICAL SCHEDULES ELECTRICAL E0.00 ELECTRICAL COVER SHEET E1.00 ELECTRICAL DEMO PLAN E2.00 ELECTRICAL INSTALL PLAN E3.00 ELECTRICAL DETAILS & SCHEDULES PLUMBING P1.00 PLUMBING PLAN REMODEL EXISTING OFFICE SPACE INTO BEHAVIORAL HEALTH CLINIC. NO CHANGE TO OCCUR IN OCCUPANCY. ALL EGRESS WILL REMAIN UNCHANGED. BUILDING IS SPRINKLERED. SCOPE OF WORK: N S 2 N D S T E S 3 R D S T E W 1ST ST E MAIN ST MAPLE DR MADISON MEMORIAL HOSPITAL PROJECT LOCATION VERTICAL CHANGES IN LEVELS 1/4" MAX BEVELED CHANGES IN LEVELS 2 11/ 4 " - 1 / 2 " MA X 48 " MIN 15 " MA X 48 " MAX 20" MA X 44 " 20" - 24" MA X 48 " MIN 15 " MA X 48 " MAX 10" MA X 46 " 24" MAX UNOBSTRUCTED FORWARD REACH OBSTRUCTED FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED SIDE REACH 34 " M A X MA X 34 " RECEPTACLE OUTLET UNOBSTRUCTED THERMOSTAT UNOBSTRUCTED SWITCH RECEPTACLES AND SWITCH MOUNTING HEIGHTS UNOBSTRUCTED FIRE ALARM PULL BOX 15 " M I N . 36 " M I N . 48 " M A X . 48 " M A X . MIN 60" MIN 60 " MIN 24 " MIN 36 " MIN 60" MIN 12" MIN 36" MIN 12" MIN 48 " MIN 30" MIN 30 " MIN 48" MIN 36" MIN 24 " MIN 48 " X MIN 60" 15 " MIN 30 "X CIRCULAR T-SHAPED FORWARD PARALLEL FORWARD APPROACH PARALLEL APPROACH MANEUVERING CLEARANCE IN AN ALCOVEPOSITION OF CELAR FLOOR OR GROUND SPACESIZE OF WHEELCHAIR TURNING SPACE MIN9" MIN 11" MIN 27 " MIN9" KNEE CLEARANCE TOE CLEARANCE 25" MAX 25" MAX MAX 6" OPERABLE PARTS SHALL NOT EXTEND BEYOND TOE CLEARANCE MIN 8" MIN 27 " FIG. 305.5 FIG. 305.7 RE F L E C T I V E S U R F A C E 40 " M A X T O F A C E O F MIRROR SOAP DISPENSER PAPER TOWEL DISPENSER 18 " M I N 24 " MA X 48 " 30 " TOILET PAPER DISPENSER SANITARY NAPKIN DISPOSAL SANITARY NAPKIN DISPENSER 66 " CUSTODIAN UTILITY SHELF 18 " M I N - 2 4 " MIN 18 " TO C O N T R O L S 48 " M A X TO C O N T R O L S 48 " M A X ELECTRIC HAND DRYER TO C O N T R O L S 48 " M A X (COORDINATE WITH ELECTRICAL) TO C O N T R O L S 40 " M A X GRAB BARS 39 " - 4 1 " MIN 18 " 33 " - 3 6 " FINISH FLOOR MA X 48 " FIRE EXTINGUISHER CABINET MA X 48 " RING MOUNTED FIRE EXTINGUISHER 48 " M A X 34 " M A X 27 " M I N DIAPER CHANGING STATION TOILET SEAT COVER DISPENSER 15 " M I N 48 " M A X BE L O W G R A B B A R S 1 1 / 2 " NOTE:WALL MOUNTED OBJECTS SHALL NOT HAVE LEADING EDGES THAT EXTEND MORE THAN 4" INTO THE CIRCULATION ROUTE AT A HEIGHT BETWEEN 27"-80" AFF. PER A117.1 307. NOTE: WALL BASE NOT PERMITTED TO ENCROACH ON MANEUVERING CLEARANCES CL E A R 60 " M I N FRONT APPROACH -PULL SIDE CLEAR 18" MIN CL E A R 48 " M I N FRONT APPROACH -PUSH SIDE *IF BOTH CLOSER AND LATCH ARE PROVIDED. CLEAR 12" MIN CL E A R 60 " M I N HINGE APPROACH -PULL SIDE CLEAR 36" MIN CL E A R 54 " M I N HINGE APPROACH -PULL SIDE (OPTIONAL) CLEAR 42" MIN CL E A R 42 " M I N HINGE APPROACH -PUSH SIDE CLEAR 22" MIN CL E A R 48 " M I N HINGE APPROACH -PUSH SIDE *IF BOTH CLOSER AND LATCH ARE PROVIDED. CLEAR 22" MIN CLEAR 12" MIN 54 " M I N I F C L O S E R I S P R O V I D E D 48 " M I N C L E A R LATCH APPROACH -PULL SIDE CLEAR 24" MIN 48 " M I N I F C L O S E R I S P R O V I D E D 42 " M I N C L E A R LATCH APPROACH -PUSH SIDE CLEAR 24" MIN MANEUVERING CLEARANCES @ MANUAL SWING DOORS (117.1 2009 SECTION 404.2.3.2) CL E A R 48 " M I N FRONT APPROACH -PUSH SIDE *IF NOT EQUIPPED WITH CLOSER AND LATCH. OPENING WIDTH O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 7/ 1 3 / 2 0 2 3 1 : 3 1 : 2 3 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 ACCESSIBILITY COMPLIANCE 23-010 AMM TB 07/13/2023 G0.02 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 6" = 1'-0"G0.02 A1 CHANGE IN LEVELS 3/8" = 1'-0"G0.02 A3 REACH RANGES 3/8" = 1'-0"G0.02 A2 MISC. MOUNTING HEIGHTS 3/8" = 1'-0"G0.02 C3 CLEAR FLOOR SPACES 3/8" = 1'-0"G0.02 B2 ACCESSORIES MOUNTING HEIGHTS, TYP. 1. WALL TYPES DESCRIBED ON THIS SHEET DO NOT ACCOUNT FOR REQUIRED BACKING AND/OR SUPPORT FOR WALL MOUNTED FIXTURES, EQUIPMENT, CASEWORK AND/OR SYSTEMS FURNITURE. COORDINATE WITH ENLARGED FLOOR PLANS, INTERIOR ELEVATIONS AND EQUIPMENT PLANS PRIOR TO THE COVERING OF STUD FRAMING. REFER TO MANUFACTURER'S RECOMMENDATIONS AND USE DETAIL A5/G0.03 WHERE APPLICABLE 2. PROVIDE SEISMIC BRACING AT ALL WALL TYPES THAT DO NOT EXTEND TO DECK 3. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE SEALED AS PER MANUFACTURERS RECOMMENDATION AND IN ACCORDANCE W/ ASSOCIATED UL LISTING 4. WALL THICKNESS DESCRIBED ON THIS SHEET ARE SHOWN NOMINALLY IN PLAN REPRESENTATIONS 5. HORIZONTAL BRACING 2'-0" A.F.F. AT FIRST OCCURRENCE AND EVERY 4'-0" THEREAFTER AT ALL WALLS W/ GYPSUM WALL BOARD ON ONLY ONE SIDE. 6. SEE A1/G0.03 FOR PARTITION PRIORITY LEGEND FOR SEQUENCING OF RATED WALL CONSTRUCTION 7. AT ALL WALLS WITH SOUND ATTENUATION, SEAL TOP OF WALL AT STRUCTURE AND BOTTOM OF WALL WITH SOUND SEALANT 8. AT ALL WALLS THAT EXTEND TO STRUCTURE PROVIDE DEFLECTION TRACK. SEE DETAILS C3 AND C5/G0.03 FOR TYPICAL CONDITION. FOR INSTANCES WHERE BEAM INTERRUPTS CONTINUATION OF WALL TO DECK ABOVE NOTIFY ARCHITECT. 9. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY IF CLEARANCES AND ADA REQUIREMENTS ARE NOT ACHIEVED. GENERAL NOTES -WALL TYPES +/- 4 3/4" WALL FIRE RATING: FIRE TEST: WALL HEIGHT: EXTERIOR INTERIOR SOUND RATING:W46S NON-RATED UL U419 (NON-BEARING) TO DECK ABOVE 45-49 STC WALL FIRE RATING: FIRE TEST: WALL HEIGHT: EXTERIOR INTERIOR SOUND RATING:W48S NON-RATED UL U419 (NON-BEARING) TO DECK ABOVE 45-49 STC INTERIOR TYPE "X" GYPSUM WALL BOARD, 5/8" 2X WOOD FRAMING INTERIOR TYPE "X" GYPSUM WALL BOARD, 5/8" SOUND INSULATION INTERIOR TYPE "X" GYPSUM WALL BOARD, 5/8" 2X WOOD FRAMING SOUND INSULATION DECKING INTERIOR TYPE "X" GYPSUM WALL BOARD, 5/8" METAL FLASHING/TRIM ACOUSTICAL JOINT SEALANT DECKING INTERIOR TYPE "X" GYPSUM WALL BOARD, 5/8" METAL FLASHING/TRIM ACOUSTICAL JOINT SEALANT STUDS. RE: FLOOR PLANS AND WALL TYPES 2X FIRE TREATED SOLID BLOCKING NON-RATED WALL SMOKE TIGHT WALL TWO HOUR FIRE AND SMOKE WALL TWO HOUR FIRE WALL TWO HOUR SHAFT WALL ONE HOUR FIRE AND SMOKE WALL ONE HOUR FIRE WALL PRIORITY 6 PRIORITY 5 PRIORITY 3 PRIORITY 4 PRIORITY 2 PRIORITY 1 HIGHEST PARTITION PRIORITY LEGEND LOWEST PRIORITY HIGHEST PRIORITY RIVET METAL ANGLE EDGE TO T-BAR @ 24" O.C. CEILING PANEL SLIP JOINT (NO RIVET) HEAVY-DUTY T-BAR GRID SYSTEM SCHEDULED WALL LAY-IN ACOUSTIC CEILING PANEL NOTE: PROVIDE PERIMETER SUPPORTING CLOSURE ANGLE. ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE ON TWO ADJACENT SIDES. THE OPPOSITE ENDS SHALL HAVE A 3/4" CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON CLOSURE ANGLE. 7/8" 3/4" MIN 7/8" C R O S S R U N N E R2" MIN MAIN RUNNER 45 deg. MAX 45 deg. MAX 2" MIN VERTICAL HANGER WIRES 4'-0" OC SPLAY HANGER WIRE AT 12'-0" O.C. EACH PLANE, EACH RUNNER 1 5/8" STUD FOR COMPRESSION 1 2 '-0 " T Y P I C A L 1 2 ' - 0 " T Y P I C A L 4 '-0 " M A X 45 O G0.03 B3 CEILING SUSPENSION SYSTEM FIRST LINE OF BRACING 4'-0" OR LESS FROM WALL BOUNDARY 2 1D 1B 1A D2 E E1D1DC3C1CB3 1A 1B 1D 2 E1ED2D1DC3C1CB3 195 SF GROUP ROOM B 10 114 SF WAITING AREA B 3 99 SF RECEPTION B 2 107 SF OFFICE 3 B 3 107 SF OFFICE 1 B 3 101 SF OFFICE 2 B 3 MAX EXIT DISTANCE: 83' -9" COMMON PATH OF TRAVEL: 28' -9" 603.1 SCOPE. -LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. CODE ANALYSIS SUMMARY CLASSIFICATION OF WORK (PER IEBC CHAPTER 6) GENERAL BUILDING HEIGHTS AND AREAS (PER IBC CHAPTER 5) CONSTRUCTION TYPE: V-B ACTUAL/EXISTING 42' -APPROX. 3 15,000 -APPROX. BUILDING HEIGHT IN FEET (TABLE 504.3): V-B (B) SPRINKLERED BUILDING HEIGHT IN STORIES (TABLE 504.4): V-B (B) NON-SPRINKLERED ALLOWABLE BUILDING AREA (506.2.3): MIXED OCCUPANCIES: ACCESSORY OCCUPANCIES ALLOWABLE 60' 3 27,000 PROJECT SUMMARY -EXISTING OCCUPANCY [BUSINESS] TO REMAIN. SPACE IS BEING RECONFIGURED FOR BEHAVIORAL HEALTH COUNSELING AND WILL ENTAIL TWO INDIVIDUAL COUNSELING ROOMS, RECEPTION AND WAITING AREA, ONE PROVIDER OFFICE SPACE AND A GROUP THERAPY ROOM. ALL EXITING ROUTES WILL BE MAINTAINED, AS EXIST CURRENTLY. THE BUILDING AND EXISTING SPACE CURRENTLY HAVE AN AUTOMATIC SPRINKLER SYSTEM THAT WILL REMAIN. JURISDICTION CITY OF REXBURG, IDAHO ZONING INFORMATION COMMERCIAL ORIGINAL CONSTRUCTION YEAR PERMITTED 2023 APPLICABLE CODES 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2018 INTERNATIONAL BUILDING CODE (IBC) 2013 NFPA 72 FIRE ALARM AND SIGNALING CODE 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2017 NATIONAL ELECTRICAL CODE (NEC) 2017 IDAHO STATE PLUMBING CODE -BASED ON THE 2015 UNIFORM PLUMBING CODE (UPC) ENERGY CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ACCESSIBILITY CODES 2018 INTERNATIONAL BUILDING CODE -USED AS SAFE HARBOR 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN 2009 ICC A117.1 INTERIOR FINISHES (PER IBC CHAPTER 8) TABLE 803.13 OCCUPANCY INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS CORRIDORS AND ENCLOSURES FOR EXIT ACCESS STAIRWAYS AND RAMPS ROOMS AND ENCLOSED SPACES B C CGROUP: B FIRE RESISTIVE RATING REQUIREMENTS FOR BUILDING ELEMENTS (PER IBC CHAPTER 6) CONSTRUCTION TYPE: PRIMARY STRUCTURAL FRAME (HOURS): BEARING WALLS-EXTERIOR (HOURS): BEARING WALLS-INTERIOR (HOURS): NONBEARING WALLS AND PARTITIONS-EXTERIOR (HOURS): X < 5' 5' < X < 10' 10' < X < 30' X > 30' NONBEARING WALLS AND PARTITIONS INTERIOR (HOURS): FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (HOURS): ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (HOURS): V-B 0 0 0 1 1 0 0 0 0 0 MEANS OF EGRESS (PER IBC CHAPTER 10) MAXIMUM EXIT ACCESS TRAVEL DISTANCE (FEET): (IBC TABLE 1017.2) MAXIMUM COMMON PATH OF EGRESS TRAVEL (FEET): (IBC TABLE 1006.2.1) B BUSINESS 300' B BUSINESS 100' GROUP(S):B OCCUPANCY CLASSIFICATION AND USE (PER IBC CHAPTER 3) 1004.8 CONCENTRATED BUSINESS USE AREAS -CONCENTRATED BUSINESS USE AREA: THE OCCUPANT LOAD FACTOR FOR CONCENTRATED BUSINESS USE SHALL BE APPLIED TO TELEPHONE CALL CENTERS, TRADING FLOORS, ELECTRONIC DATA PROCESSING CENTERS AND SIMILAR BUSINESS USE AREAS WITH A HIGHER DENSITY OF OCCUPANTS THAN WOULD NORMALLY BE EXPECTED IN A TYPICAL BUSINESS OCCUPANCY ENVIRONMENT. WHERE APPROVED BY THE BUILDING OFFICIAL, THE OCCUPANT LOAD FOR CONCENTRATED BUSINESS USE AREAS SHALL BE THE ACTUAL OCCUPANT LOAD, BUT NOT LESS THAN ONE OCCUPANT PER 50 SQUARE FEET (4.65 M2) OF GROSS OCCUPIABLE FLOOR SPACE. FIRE BARRIER -1-HOUR FIRE-RESISTIVE RATING PER IBC SECTION 706 WITH 60-MINUTE RATED OPENING PROTECTIVES PER IBC TABLE 716.5 LEGEND -EXITING AND OCCUPANCY PLAN ROOM NAME X-1 ## OCCUPANCY CLASSIFICATION (PER IBC CHAPTER 3) ROOM OCCUPANT LOAD (PER IBC TABLE 1004.1.2) EXITING TRAVEL DISTANCE EXISTING BUILDING AREA OF TENENT IMPROVEMENT O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 7/ 1 3 / 2 0 2 3 1 : 3 1 : 2 5 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 CODE COMPLIANCE, EXITING AND OCCUPANCY, WALL TYPES AND DETAILS 23-010 AMM TB 07/13/2023 G0.03 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 1 1/2" = 1'-0" WALL TYPES - INTERIOR 01 1 1/2" = 1'-0"G0.03 C3 FRAMING DETAIL TO DECK (PARALLEL TO FLUTES) 1 1/2" = 1'-0"G0.03 C5 FRAMING WALL TO DECK (PERPENDICULAR TO FLUTES) 1/2" = 1'-0"G0.03 A5 MOUNTING PLATE ELEVATION, TYP. 3" = 1'-0"G0.03 A1 PARTITION PRIORITY LEGEND 3" = 1'-0"G0.03 A3 TYPICAL LAY-IN CEILING TILE EDGE DETAIL 12" = 1'-0"G0.03 B3 TYPICAL SEISMIC BRACING DETAIL-01 12" = 1'-0"G0.03 B5 TYPICAL SEISMIC BRACING DETAIL-02 1/8" = 1'-0"G0.03 11 LEVEL 1 - AREA EXITING AND OCCUPANCY PLAN 1" = 20'-0"G0.03 D4 LEVEL 1 - OVERALL EXITING AND OCCUPANCY PLAN NN 2 1D 1B 1A 3 4 D2 E E1D1DC3C1CB3B A6 A4A2A1A 4A 5 5A 5B 6 PROJECT AREA A2.11 E4 EXISTING BUILDING 753 SF 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES. 2. CONTRACTOR TO NOTIFY ARCHITECT IF REQUIRED ACCESSIBILITY AND EQUIPMENT CLEARANCES WILL NOT BE MAINTAINED. 3. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR NEW GWB WALLS / PARTITIONS. 4. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO FACE OF FINISH FOR EXISTING CONSTRUCTION. 5. UNLESS NOTED OTHERWISE ALL GWB WALLS SHALL HAVE A 4" STUD FRAME RETURN AT ALL DOOR AND WINDOW JAMBS. 6. UNLESS NOTED OTHERWISE, RE: G0.02b FOR TYPICAL MANEUVERING CLEARANCE REQUIREMENTS FOR ALL DOORS. 7. RE: G SERIES SHEETS FOR BUILDING OCCUPANCY PLANS AND FIRE RESISTIVE CONSTRUCTION REQUIREMENTS. 8. FOR GLAZING RECEIVING WINDOW TREATMENTS, COORDINATE WITH ROOM FINISH SCHEDULE AND PLANS. 9. FOR WALLS NOT DESIGNATED WITH A WALL TYPE, COORDINATE WITH ARCHITECT. GENERAL NOTES -FLOOR PLANS STUD WALL AND GYPSUM WALL BOARD WALL. RE: WALL TYPES. WALL TYPE, RE: SHEET G0.03 DOOR SYMBOL, RE: DOOR SCHEDULE, SHEET A7.01 LEGEND XXXx XXXXXXX NOT IN PROJECT SCOPE O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 7/ 1 3 / 2 0 2 3 1 : 3 1 : 2 6 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 LEVEL 1 - COMPOSITE FLOOR PLAN 23-010 AMM TB 07/13/2023 A2.01 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 1/8" = 1'-0"A2.01 E1 LEVEL 1-COMPOSITE FLOOR PLAN N NOTES - REFERENCE NOTES T TT 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES. 2. CONTRACTOR TO NOTIFY ARCHITECT IF REQUIRED ACCESSIBILITY AND EQUIPMENT CLEARANCES WILL NOT BE MAINTAINED. 3. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR NEW GWB WALLS / PARTITIONS. 4. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO FACE OF FINISH FOR EXISTING CONSTRUCTION. 5. UNLESS NOTED OTHERWISE ALL GWB WALLS SHALL HAVE A 4" STUD FRAME RETURN AT ALL DOOR AND WINDOW JAMBS. 6. UNLESS NOTED OTHERWISE, RE: G0.02b FOR TYPICAL MANEUVERING CLEARANCE REQUIREMENTS FOR ALL DOORS. 7. RE: G SERIES SHEETS FOR BUILDING OCCUPANCY PLANS AND FIRE RESISTIVE CONSTRUCTION REQUIREMENTS. 8. FOR GLAZING RECEIVING WINDOW TREATMENTS, COORDINATE WITH ROOM FINISH SCHEDULE AND PLANS. 9. FOR WALLS NOT DESIGNATED WITH A WALL TYPE, COORDINATE WITH ARCHITECT. GENERAL NOTES -FLOOR PLANS STUD WALL AND GYPSUM WALL BOARD WALL. RE: WALL TYPES. WALL TYPE, RE: SHEET G0.03 DOOR SYMBOL, RE: DOOR SCHEDULE, SHEET A7.01 LEGEND XXXx XXXXXXX NOT IN PROJECT SCOPE 2 1D 1B 1A D2 E E1D1DC3C1 8' - 0" 4" A7.01 E4 A7.01 E5 OFFICE 2 215 OFFICE 1 216 OFFICE 3 217 GROUP ROOM 218 WAITING AREA 219 RECEPTION 220 W4 6 S W4 6 S W4 6 S W46S W48S 215 218 217 8.04 1.01 1.01 1.01 1.01 1.02 1.02 1.02 1A 1B 1D 2 E1ED2D1DC3C1 9.18 216 2 1D 1B 1A D2 E E1D1DC3C1 OFFICE 2 215 OFFICE 1 216 OFFICE 3 217 GROUP ROOM 218 WAITING AREA 219 RECEPTION 220 1A 1B 1D 2 E1ED2D1DC3C1 9' - 10" A.F.F. 9' - 10" A.F.F. 9' - 10" A.F.F. 9' - 10" A.F.F. 9' - 10" A.F.F. 2 1D 1B 1A D2 E E1D1DC3C1 1A 1B 1D 2 E1ED2D1DC3C1 2.11 2 1D 1B 1A D2 E E1D1DC3C1 2.07 2.07 2.07 2.07 2.08 2.07 2.07 2.04 2.04 2.09 2.04 2.06 2.09 4" 4' - 5 1/2" 2.10 2.10 2.10 2.10 2.10 2.12 2.122.12 1. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL ITEMS TO BE PROVIDED AT THE CEILING PLANE AND IN THE WORK. 2. CENTER ALL LIGHT FIXTURES AND SPRINKLER HEADS IN THEIR RESPECTIVE CEILING PANEL. 3. INSTALL ALL SUSPENSION SYSTEMS FOR ACOUSTICAL PANEL CEILINGS PER PROVISIONS OF ASTM C 635 AND ASTM C 636. 4. ALL SOFFIT DIMENSIONS SHOWN ARE TO FACE OF FINISH. 5. COORDINATE WITH MECHANICAL & ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR PHYSICAL SIZES OF ALL CEILING GRILLES, DIFFUSERS, FIXTURES, CANS, AND ALL RELATED ITEMS. 6. PAINT ALL EXPOSED-TO-VIEW STRUCTURAL STEEL DECK, AND ASSOCIATED STRUCTURAL ITEMS PAINT COLOR P-1, UNLESS OTHERWISE NOTED. 7. PAINT ALL EXPOSED-TO-VIEW MECHANICAL DUCTWORK AND ASSOCIATED ITEMS, ELECTRICAL CONDUIT AND ASSOCIATED ITEMS, PLUMBING AND FIRE PROTECTION LINES AND ALL ASSOCIATED ITEMS PAINT COLOR P-1, UNLESS OTHERWISE NOTED. 8. SUSPENSION SYSTEMS FOR GYPSUM BOARD CEILINGS SHALL BE INSTALLED PER ASTM C754. GENERAL NOTES -CEILINGS O.T.S. X' -X" LEGEND 2' x 2' ACOUSTICAL CEILING METAL SUSPENSION SYSTEM WITH ACOUSTICAL PANEL CEILING UNITS, APC-1, U.O.N. RE: FINISH SCHEDULE. OPEN TO STRUCTURE VERTICAL SERVICE DROP/CHASE. COORDINATE WITH MECHANICAL DRAWINGS. LIGHTING FIXTURES, COORDINATE WITH ELECTRICAL DRAWINGS. MECHANICAL FIXTURES, COORDINATE WITH MECHANICAL DRAWINGS. CEILING HEIGHT ABOVE FINISH FLOOR EXISTING ACOUSTICAL CEILING SYSTEM TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. REPLACE DAMAGED CEILING UNITS. EXISTING ACOUSTICAL CEILING SYSTEM TO BE REMOVED. COORDINATE WITH NEW CONSTRUCTION SCOPE OF WORK. 1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR GWB WALLS/PARTITIONS. 2. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO FACE OF FINISH FOR EXISTING CONSTRUCTION. 3. SCREENED LINES REPRESENT EXISTING WALLS, DOORS, WINDOWS, ETC TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION ACTIVITIES. 4. FOR DIMENSIONAL EXTENTS OF EXISTING WALL DEMOLITION, CUTTING AND PATCHING, SEE NEW FLOOR PLANS. 5. PROTECT FROM DAMAGE ALL EXISTING TO REMAIN CASEWORK, EQUIPMENT, FLOOR FINISHES AND CEILING FINISHES DURING CONSTRUCTION. 6. PROTECT FROM DAMAGE DURING DEMOLITION, MOVING AND CONSTRUCTION ALL EXISTING CASEWORK, EQUIPMENT, FURNITURE AND ARTWORK THAT IS TO BE RE-USED. 7. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION WORK. 8. COORDINATE THE DEMOLITION OF EXISTING CEILING WITH NEW PLANS, REFLECTED CEILING PLANS AND ROOM FINISH SCHEDULE. 9. WHERE EXISTING CARPET/CARPET TILE ARE TO REMAIN, CUT AND PATCH CARPET AS REQUIRED TO FACILITATE NEW CONSTRUCTION. GENERAL NOTES -DEMO EXISTING WALL SYSTEM TO BE REMOVED AND ALL ASSOCIATED ITEMS TO ACCOMODATE NEW CONSTRUCTION. RELOCATE MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED TO ACCOMODATE NEW CONSTRUCTION. COORDINATE REMOVAL OF WALL SYSTEM, PATCH AND REPAIR WITH NEW CONSTRUCTION SCOPE OF WORK. EXISTING DOOR SYSTEM TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. EXISTING WALL SYSTEM TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION. LEGEND EXISTING DOOR SYSTEM TO REMOVED AND ALL ASSOCIATED ITEMS TO ACCOMODATE NEW CONSTRUCTION. COORDINATE REMOVAL OF DOOR SYSTEM, PATCH AND REPAIR WITH NEW CONSTRUCTION SCOPE OF WORK. EXISTING WINDOW TO REMAIN EXISTING WINDOW AND FRAME TO BE REMOVED O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 7/ 1 3 / 2 0 2 3 1 : 3 1 : 2 8 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 LEVEL 1 -DEMO AND AREA FLOOR AND CEILING PLANS 23-010 AMM TB 07/13/2023 A2.11 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 N NOTES - REFERENCE NOTES 1.01 ALIGN FACE OF NEW WALL PLANE WITH EXISTING WALL PLANE, THERE SHALL BE NO NOTICEABLE SEAMS OR BREAKS IN FINISHED APPEARANCE OF THE WALL. 1.02 VERIFY EXISTING WALL CONDITIONS. EXTEND PARTIAL-HEIGHT WALL TO DECK, INCLUDING SOUND INSULATION. 2.04 REMOVE EXISTING WALL SYSTEM AND ALL ASSOCIATED ITEMS. RELOCATE MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED TO ACCOMODATE NEW CONSTRUCTION. COORDINATE REMOVAL OF WALL SYSTEM, PATCH AND REPAIR WITH NEW CONSTRUCTION SCOPE OF WORK. 2.06 EXISTING WALL SYSTEM. PRESERVE, PROTECT AND REPAIR DAMAGED AREAS TO ORIGINAL STATE. 2.07 REMOVE AND SALVAGE TO OWNER CASEWORK, COUNTERS, AND ALL ASSOCIATED ITEMS. 2.08 EXISTING CASEWORK AND COUNTERS TO REMAIN. PRESERVE, PROTECT, AND REPAIR DAMAGED AREAS TO ORIGINAL STATE. 2.09 REMOVE EXISTING WALL SYSTEM AND ALL ASSOCIATED ITEMS TO RECEIVE NEW DOOR. RELOCATE MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED TO ACCOMODATE NEW CONSTRUCTION. COORDINATE WITH NEW CONSTRUCTION SCOPE OF WORK. 2.10 REMOVE EXISTING FLOORING AND ACCESSORIES, INCLUDING WALL BASE. PREPARE SURFACES TO RECEIVE NEW FINISHES. 2.11 REMOVE AND REINSTALL ALL EXISTING FIXTURES AND CEILING GRID FOR NEW CONSTRUCTION. TIE INTO EXISTING GRID AND MATCH EXISTING FINISHES AS REQUIRED TO COMPLETE CEILING ASSEMBLY AT NEW WALL INSTALLATION AND MECHANICAL WORK. 2.12 REMOVE SECTIONS OF WALL FINISH AS REQUIRED TO INSTALL ELECTRICAL AND PLUMBING. PATCH AND REPAIR AREAS TO ORIGINAL STATE. COORDINATE WITH MEP DRAWINGS AND NEW CONSTRUCTION SCOPE OF WORK. 8.04 INSTALL PRIVACY FILM TO GLAZING. OFCI. 9.18 PROVIDE AND INSTALL WINDOW TREATMENTS RE: FINISH SCHEDULE AND LEGEND. 3/16" = 1'-0"A2.11 E4 LEVEL 1 - AREA FLOOR PLAN 3/16" = 1'-0"A2.11 C4 LEVEL 1 - AREA CEILING PLAN 3/16" = 1'-0"A2.11 C1 LEVEL 1 - DEMO AREA CEILING PLAN 3/16" = 1'-0"A2.11 E1 LEVEL 1 - DEMO AREA FLOOR PLAN ALUM -ALUMINUM FF -FACTORY FINISH AS SPECIFIED HM -HOLLOW METAL HPC -HIGH PERFORMANCE COATING M -MINUTES P#-PAINT COLOR "NUMBER" (RE: DIVISION 9 SECTION "INTERIOR PAINTING". WD -WOOD S -SMOKE AN -ANODIZED ABBREVIATIONS F RE : D O O R S C H E D U L E AS S C H E D U L E D RE: DOOR SCHEDULE AS SCHEDULED 1. REPAINT ALL DOORS, DOOR FRAMES, WINDOW FRAMES, AND TRIM TO MATCH EXISTING. 2. PAINT ALL METAL FRAMES & ACCESSORIES P-2. 3. ALL HOLLOW METAL FRAME GLAZING STOPS TO BE PLACED ON ROOM SIDE OPPOSITE FROM HALLWAY / CORRIDOR. 4. PROVIDE FULLY TEMPERED FIRE-RATED GLAZING IN METAL FRAMES AND DOORS WHERE 60M ASSEMBLY AT DOORS ARE REQUIRED (RE: DOOR SCHEDULE). FIRE-RATED GLAZING ASSEMBLY SHALL BE 60M. 5. PROVIDE FULLY TEMPERED GLASS UNITS WHERE REQUIRED BY I.B.C. SECTION 2406. 6. PROVIDE FLOAT GLASS AT CONDITIONS OTHER THAN DESCRIBED IN THESE GENERAL NOTES. 7. GLASS AT 60M OPENINGS SHALL BE FULLY TEMPERED FIRE-RATED GLAZING AND CARRY 60M LABEL. WIRE GLASS DOES NOT CARRY THIS LABEL. 8. COORDINATE ALL INDICATED FRAME DETAILS WITH ACTUAL WALL CONFIGURATION. APPLY DETAILS AS APPLICABLE. GENERAL NOTES AS S C H E D U L E D 2" 2"AS SCHEDULED2" S1 A1 A7.01 FLOOR FINISHES ABBREVIATIONS -FINISHES CPT CARPET TILE CT CERAMIC TILE LN LINOLEUM LVP LUXURY VINYL PLANK LVT LUXURY VINYL TILE MCB METAL COVE BASE PC POLISHED CONCRETE QT QUARRY TILE QVT QUARTZ VINYL TILE RF RUBBER FLOOR TILE WALL BASE CT CERAMIC TILE QTB QUARRY TILE BASE RB RESILIENT BASE TZB TERRAZZO BASE WDB WOOD BASE WALL FINISHES CT CERAMIC TILE GT GLASS TILE FRP PLASTIC SHEET PANELING P PAINT RP RESIN PANEL RMA RESILIENT MOLDING ACCESSORY WC VINYL WALL COVERING WDP WOOD PANELING WP WRAPPED FABRIC PANEL CEILINGS APC ACOUSTICAL PANEL CEILING WD WOOD CEILING GBD GYPSUM BOARD CASEWORK PL PLASTIC LAMINATE SDS SOLID SURFACE TF TRANSPARENT FINISH WDP WOOD PANELING RFA RESILIENT FLOOR ACCESSORY RSA RESILENT STAIR ACCESSORY RSV RIGID SHEET VINYL SC SEALED CONCRETE SD STATIC DISSIPATIVE FLOOR TILE SV VINYL SHEET FLOOR COVERING T TILE TT TILE TRIM TZ TERRAZZO WCV WINDOW COVERING WM WALK OFF MAT WINDOW TREATMENT WT WINDOW TREATMENT 1. RE: ROOM FINISH SCHEDULE SHEET FOR ADDITIONAL INFORMATION ON FLOOR AND WALL FINISHES. 2. TILE PATTERNS MUST MAINTAIN EXACT CONFIGURATION SHOWN. 3. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 4. RE: REFLECTED CEILING PLANS FOR CEILING AND SOFFIT PAINT COLOR LOCATIONS. 5. ALL TILE PATTERNS ARE TO BE FULL TILES EXCEPT WHERE PATTERN IS INTERRUPTED BY PORTIONS OF BUILDING. SEE INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. 6. FOR RUBBER WALL BASE JOB FORM INSIDE AND OUTSIDE CORNERS. 7. PROVIDE ADA COMPLIANT FLOOR ACCESSORIES FOR FLOORING TRANSITIONS. 8. NOT ALL FLOOR FINISHES ARE SHOWN ON FLOOR FINISH PLANS. RE: ROOM FINISH SCHEDULE FOR ALL FLOOR FINISH LOCATIONS. 9. ALL DOOR AND WINDOW TRIM TO BE PAINT COLOR P-# UNLESS OTHERWISE NOTED ON DOOR SCHEDULE. GENERAL NOTES -FINISHES 1. RE: ROOM FINISH SCHEDULE AND FINISH FLOOR PLANS FOR MATERIAL AND FINISH INFORMATION. 2. RE: BUILDING INFORMATION SHEETS FOR CODE AND FIRE INFORMATION. 3. RE: FLOOR PLANS AND DOOR SCHEDULE FOR DOOR AND FRAME TYPES. 4. PROVIDE RWB AT ALL TOE SPACES OF ALL CABINETS, SIDES OF CABINETS AND ALL KNEE SPACES BELOW CABINETS. 5. PROVIDE BLOCKING FOR ALL WALL-MOUNTED ACCESSORIES AND EQUIPMENT. GENERAL NOTES - INTERIOR ELEVATIONS CASEWORK TAG LEGEND MODEL NUMBER INDICATES MODEL NUMBER OF AWS CABINET M INDICATES A MODIFIED VERSION OF THE AWS CABINET MODEL REPRESENTED BY THE PRECEDING NUMBER. WIDTH INDICATES WIDTH OF CABINET, DIMENSIONED FROM OUTSIDE FACE TO OUTSIDE FACE. DEPTH INDICATES DEPTH OF CABINET, DIMENSIONED FROM FACE OF WALL TO FACE OF CABINET. HEIGHT INDICATES HEIGHT OF CABINET, DIMENSIONED FROM FACE OF FINISHED FLOOR TO TOP OF COUNTERTOP FOR BASE CABINETS AND FROM BOTTOM OF CABINET TO TOP OF CABINET FOR UPPER CABINETS. MODIFICATION A DESCRIPTION OF THE MODIFICATION MADE INDICATED BY THE (M) FOLLOWING THE MODEL NUMBER ###M 36" 36" 16" Extra Shelf MODEL NUMBER WIDTH HEIGHT DEPTH DESCRIPTION OF MODIFICATION "M" INDICATES CABINET IS MODIFIED REF NOTE FOR DESCRIPTION OF AN EXPANDED MODIFICATION ## TO T O P O F C O N T R O L S 4' - 0 " 2.05 10.10 8.04 EQ EQ 101M 17" 34" 24" NO SHELF 151 18" 34" 24" LOCKABLE 254 18" 34" 24" LOCKABLE 211 16" 34" 24" LOCKABLE 401 24" 84" 24" LOCKABLE 302 34" 28" 14" LOCKABLE (2) 6.07 6.116.05 10.04 10.05 10.11 22.03 SOUND ATTENUATION BLANKET INSULATION. RE: FLOOR PLANS AND WALL TYPES. GYPSUM WALL BOARD TYPE 'X' WOOD STUD FRAMING. RE: FLOOR PLANS AND WALL TYPES. JOINT SEALANT GYPSUM WALL BOARD TYPE 'X' JOINT SEALANT HOLLOW METAL FRAME. RE: FLOOR PLANS, DOOR SCHEDULE AND DOOR AND FRAME TYPES. HOLLOW METAL DOOR. RE: FLOOR PLANS, DOOR SCHEDULE AND DOOR AND FRAME TYPES.FRAME BEYOND O H E S T TA PD NE L I C RA ES C F I D A OH L EFOR A N I T S CET OIS G A R Y A.SOR E N S E N J R . AR-984526 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E 7/ 1 3 / 2 0 2 3 1 : 3 1 : 2 9 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 DOOR SCHEDULE & TYPES, FINISHES, INTERIOR ELEVATIONS 23-010 AMM TB 07/13/2023 A7.01 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 1/2" = 1'-0" DOOR TYPES 1/2" = 1'-0" STEEL FRAME TYPES SCHEDULE - DOOR DOOR # DOOR FRAME DOOR HARDWARE REMARKSTYPEWIDTHHEIGHTMATERIALFINISHTYPEMATERIALFINISH 215 F 3' - 0" 7' - 0" WD S1 WD PASSAGE MATCH EXISTING 216 F 3' - 0" 7' - 0" WD S1 WD PASSAGE MATCH EXISTING 218 F 3' - 0" 7' - 0" WD S1 WD PASSAGE MATCH EXISTING NOTES - REFERENCE NOTES 2.05 EXISTING GLAZING SYSTEM TO REMAIN. PROTECT FROM DAMAGE. 6.05 8" DIAMETER OPENING IN TOP OF COUNTER FOR TRASH CAN ACCESS. PROVIDE PVC EDGEBANDING AT ALL OPENING EDGES. 6.07 PLASTIC LAMINATE CABINETS. RE: FINISH SCHEDULE. TYP. 6.11 1-1/4" PLASTIC LAMINATE WRAPPED PANEL CORE COUNTERTOP WITH BACKSPLASH. RE: FINISH SCHEDULE. 8.04 INSTALL PRIVACY FILM TO GLAZING. OFCI. 10.04 WALL MOUNTED PAPER TOWEL DISPENSER, OFCI. 10.05 WALL MOUNTED SOAP DISPENSER. OFCI 10.10 WALL MOUNTED TV. PROVIDE BLOCKING. COORDINATE LOCATION WITH OWNER. OFCI. RE: ELECTRICAL. 10.11 WALL MOUNTED SHARPS AND GLOVES DISPENSER/DISPOSAL. OFCI. 22.03 HANDWASH SINK. COORDINATE WITH PLUMBING DRAWINGS. SCHEDULE - FINISH LEGEND FINISH PRODUCT DESCRIPTION MANUFACTURER PRODUCT NUMBER COLOR COMMENTS ACT-1 CEILING TILE ARMSTRONG - WHITE MATCH EXISTING ACT-GRID CEILING GRID - WHITE MATCH EXISTING CPT-1 CARPET TILE J+J FLOORING OUTFITTER MODULAR 7064 OILCLOTH 2399 OFCI P-1 PAINT (FIELD) SHERWIN WILLIAMS NATURAL TAN SW7567 P-2 PAINT (TRIM) WHITE MATCH EXISTING PL-1 PLASTIC LAMINATE CASEWORK MATCH EXISTING RB-1 RUBBER WALL BASE BLACK COORDINATE WITH OWNER SDS-1 SOLID SURFACE COUNTERTOP LG HORIZON COORDINATE WITH OWNER WT-1 ROLLER SHADE COORDINATE WITH OWNER WT-1 WINDOW PRIVACY FILM IMAGEPERFECT iD7 WindowEtch SILVER FROST OFCI SCHEDULE - ROOM FINISH ROOM NO.ROOM TITLE FLOOR WALLS CASEWORK WINDOW TREATMENT REMARKSMAT.BASE NORTH EAST SOUTH WEST CABINETRY COUNTER TOP 215 OFFICE 2 CPT-1 RB-1 P-1 P-1 P-1 P-1 PL-1 SDS-1 N/A 216 OFFICE 1 CPT-1 RB-1 P-1 P-1 P-1 P-1 N/A SDS-1 N/A 217 OFFICE 3 CPT-1 RB-1 P-1 P-1 P-1 P-1 N/A SDS-1 N/A 218 GROUP ROOM CPT-1 RB-1 P-1 P-1 P-1 P-1 N/A SDS-1 WT-1 219 WAITING AREA CPT-1 RB-1 P-1 P-1 P-1 P-1 N/A SDS-1 N/A 220 RECEPTION CPT-1 RB-1 P-1 P-1 P-1 P-1 N/A SDS-1 N/A 1/4" = 1'-0"A7.01 E4 GROUP ROOM - SOUTH ELEVATION 1/4" = 1'-0"A7.01 E5 OFFICE 2 - SOUTH ELEVATION 3" = 1'-0"A7.01 A1 TYP HEAD DETAIL (JAMB SIM) (HM FRAME/WOOD FRAMED WALL) M AIRFLOW AIRFLOW S T FCO H WCO S GCO CO2 CO NO SD -- # AW AV SD D-X CFM X"Ø RD R-X X"Ø OD R-X CFM X"Ø CD G-X CFM X"Ø TW TS MPG FS G F GWS GWR CWS CWR CS CR HWS HWR L S MECHANICAL ABBREVIATIONS A/C or AC AIR CONDITIONING KW KILOWATT AFF ABOVE FINISHED FLOOR KWH KILOWATT HOUR AHU AIR HANDLING UNIT ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS LAT LEAVING AIR TEMPERATURE LAV LAVATORY BTU BRITISH THERMAL UNITS LEED LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN BTUH BTUS PER HOUR LWT LEAVING WATER TEMPERATURE CA COMBUSTION AIR MAX MAXIMUM CC COOLING COIL MCA MINIMUM CIRCUIT AMPS CFM AIR FLOW RATE (CUBIC FEET PER MINUTE)MOCP MAXIMUM OVERCURRENT PROTECTION CHWR CHILLED WATER RETURN MIN MINIMUM CHWS CHILLED WATER SUPPLY CLG CEILING NC NOISE CRITERIA CW COLD WATER NFPA NATIONAL FIRE PROTECTION ASSOCIATION NTS NOT TO SCALE DEG or ° DEGREE DIA or Ø DIAMETER OSA OUTSIDE AIR DB DRY BULB PD PRESSURE DROP EA EXHAUST AIR PH or Ø PHASE EAT ENTERING AIR TEMPERATURE PRV PRESSURE REDUCING VALVE EER ENERGY EFFICIENCY RATIO ESP EXTERNAL STATIC PRESSURE RA RETURN AIR EWT ENTERING WATER TEMPERATURE RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT FCO FLOOR CLEANOUT FD FIRE DAMPER SA SUPPLY AIR FLA FULL LOAD AMPS SEER SEASONAL ENERGY EFFICIENCY RATIO FLR FLOOR SFD COMBINATION SMOKE/FIRE DAMPER FPM FEET PER MINUTE SP STATIC PRESSURE FT FEET SYM SYMBOL GA GAUGE T & P TEMPERATURE AND PRESSURE GCO GRADE CLEANOUT TEMP TEMPERATURE GPM WATER FLOW RATE (GALLONS PER MINUTE) TYP TYPICAL HC HEATING COIL UMC UNIFORM MECHANICAL CODE HP HORSE POWER UPC UNIFORM PLUMBING CODE HVAC HEATING, VENTILATING, AIR CONDITIONING URL URINAL HW HOT WATER HWR HOT WATER RETURN VTR VENT THROUGH ROOF HWS HOT WATER SUPPLY V VOLTS IBC INTERNATIONAL BUILDING CODE W/ WITH IEEC INTERNATIONAL ENERGY CONSERVATION CODE WB WET-BULB IFC INTERNATIONAL FIRE CODE WC WATER CLOSET IFGC INTERNATIONAL FUEL GAS CODE WCO WALL CLEANOUT IMC INTERNATIONAL MECHANICAL CODE WH WATER HEATER IPC INTERNATIONAL PLUMBING CODE NOTE:THIS IS A STANDARD LIST OF COMMONLY USED MECHANICAL ABBREVIATIONS. SOME OF THE ABBREVIATIONS SHOWN ABOVE MAY NOT BE USED IN THIS DRAWING PACKAGE. MECHANICAL AND PLUMBING DRAWINGS LEGEND FLEXIBLE DUCTWORK THREE WAY CONTROL VALVE DUCTWORK TWO WAY CONTROL VALVE DUCTWORK BREAK PRESSURE REDUCING VALVE DUCTWORK OR PIPING RISE GATE VALVE CONCENTRIC SQUARE TO ROUND TRANSITION REDUCER MOTORIZED DAMPER GLOBE VALVE MANUAL VOLUME DAMPER BALL VALVE SPIN-IN FITTING W/ AIR EXTRACTOR AND HAND DAMPER BUTTERFLY VALVE HIGH EFFICIENCY FITTING W/ HAND DAMPER BALANCE VALVE SWITCH CHECK VALVE THERMOSTAT FLOOR CLEANOUT HUMIDISTAT WALL CLEANOUT TEMPERATURE SENSOR GRADE CLEANOUT CARBON DIOXIDE SENSOR WATER HAMMER ARRESTOR CARBON MONOXIDE SENSOR FLOOR DRAIN NITROUS OXIDE SENSOR FLOOR SINK DUCT SMOKE DETECTOR GAS PRESSURE REGULATOR W/ GAS COCK COMBINATION SMOKE/FIRE DAMPER PRESSURE RELIEF VALVE FIRE DAMPER VENT-THROUGH-ROOF SMOKE DAMPER VENT EQUIPMENT CALLOUT SOIL, WASTE, OR SANITARY SEWER TURNING VANES ACID WASTE LINE INTAKE OR EXHAUST ACID VENT LINE DIRECTION OF AIRFLOW STORM DRAIN SUPPLY DIFFUSER ROOF DRAIN LINE RETURN GRILLE OVERFLOW DRAIN LINE EXHAUST GRILLE CONDENSATE DRAIN LINE FLOOR GRILLE DOMESTIC COLD WATER (CW) CEILING EXHAUST FAN DOMESTIC HOT WATER (HW) TEMPERATURE GAUGE DOMESTIC HOT WATER RETURN (HWR) PRESSURE GAUGE (LIQUID FILLED W/ ISOLATION VALVE)TEMPERED WATER (TW) TEMPERATURE SENSOR (DUCT OR PIPING)MEDIUM PRESSURE NATURAL GAS FLOW SWITCH LOW PRESSURE NATURAL GAS STAINLESS STEEL BRAIDED FLEX CONNECTION FIRE SPRINKLER LINE ELASTOMETRIC FLEX CONNECTOR GEOTHERMAL WATER SUPPLY SUCTION DIFFUSER GEOTHERMAL WATER RETURN Y TYPE STRAINER (1-1/2" OR LARGER PROVIDED W/ BLOW DOWN VALVE)CHILLED WATER SUPPLY FLOW DIRECTION CHILLED WATER RETURN DEMOLITION / EQUIPMENT TO BE REMOVED CONDENSER WATER SUPPLY NEW TO EXISTING CONNECTION POINT CONDENSER WATER RETURN (E)EXISTING HEATING WATER SUPPLY (F)FUTURE HEATING WATER RETURN (N)NEW LIQUID REFRIGERANT LINE REDUCED PRESSURE BACKFLOW PREVENTER SUCTION REFRIGERANT LINE DOUBLE CHECK BACKFLOW PREVENTER SLOPE PIPE IN DIRECTION OF ARROW UNION PIPE ANCHOR AIR VENT PIPE GUIDE TRIPLE DUTY VALVE CAP NOTE:THIS IS A LIST OF COMMONLY USED MECHANICAL AND PLUMBING SYMBOLS. SOME OF THE SYMBOLS SHOWN ABOVE MAY NOT BE USED IN THIS DRAWING PACKAGE. MECHANICAL GENERAL NOTES 1. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE (IMC) LATEST EDITION, AND ALL APPLICABLE LOCAL AND STATE CODES. 2. ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST ADOPTED PLUMBING CODE, AND ALL LOCAL AND STATE CODES. 3. ALL MECHANICAL AND PLUMBING EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS. 4. MECHANICAL CONTRACTORS SHALL RECEIVE PRIOR APPROVAL FROM THE STRUCTURAL ENGINEER BEFORE MAKING CUTS THROUGH ANY STRUCTURAL MEMBER. 5. MECHANICAL CONTRACTORS SHALL COORDINATE INSTALLATION WITH CONSTRUCTION SUPERVISOR AND WITH ALL OTHER TRADES TO AVOID CONFLICTS. 6. THE MECHANICAL CONTRACTORS SHALL VERIFY MOTOR VOLTAGES WITH THE ELECTRICAL DRAWINGS PRIOR TO ORDERING MOTORIZED EQUIPMENT AND CONTROLS. 7. SEE MECHANICAL SCHEDULE SHEET FOR SCHEDULED CAPACITIES OF ALL MECHANICAL EQUIPMENT AND MATERIALS SPECIFIED. 8. DOMESTIC WATER SERVICE IS PROVIDED WITH AN EXISTING BACKFLOW PREVENTER ASSEMBLY. 9. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR ALL BACKFLOW DEVICES TO INSPECTED BY A CERTIFIED BACKFLOW TECHNICIAN BEFORE THE USE OF THE BUILDING POTABLE WATER SYSTEM. 10. ALL MECHANICAL EQUIPMENT TO BE PROPOSED MUST BE ON THE APPROVED LIST PRIOR TO SUBMITTALS. ALL APPROVED MANUFACTURERS MUST BE CAPABLE OF MEETING THE REQUIREMENTS OF THE SPECIFIED EQUIPMENT. 11. RUNOUT AND HOOKUP SIZES TO INDIVIDUAL PLUMBING FIXTURES CAN BE FOUND ON THE PLUMBING FIXTURE SCHEDULE. 12. PROVIDE REMOTE CEILING ACCESS BALANCE DAMPERS WITH CONCEALED CHROME PLATE COVERS FOR BALANCE DAMPERS LOCATED ABOVE HARD CEILINGS. 13. PAINT VTR'S, FLUES, EXHAUST CAPS, AND OTHER MECHANICAL ITEMS ON THE ROOF TO MATCH THE ROOF COLOR. 14. INSULATED FLEXIBLE DUCTWORK--IN LENGTHS OF 6'-0" OR LESS--MAY BE USED FOR RUNOUTS TO AIR TERMINALS. 15. MAINTAIN MINIMUM 10'-0" DISTANCE BETWEEN ALL FRESH AIR INTAKES AND EXHAUST OR GAS FLUE DISCHARGES. 16. LOCATE ACCESS HATCHCES SO AS TO PROVIDE OPTIMUM SERVICEABILITY TO EQUIPMENT AND/OR VALVING. SEE ARCHITECTURAL SPECIFICATION FOR TYPE AND COLOR. COORDINATE LOCATION WITH ARCHITECTURAL, STRUCTURAL, AND LIGHTING. 17. WHENEVER THERE IS A DISCREPANCY BETWEEN THE RUNOUT DUCT SIZE SHOWN ON THE PLANS AND THAT SHOWN IN THE SCHEDULE, ALWAYS USE THE LARGER OF THE TWO DUCT SIZES. 18. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VERIFICATION OF EXISTING JOB CONDITIONS PRIOR TO BID. NO ADDITIONAL COST SHALL BE AWARDED TO THE SUCCESSFUL CONTRACTOR (OR THEIR SUBCONTRACTORS) AFTER BIDS HAVE BEEN SUBMITTED AND CONTRACTS AWARDED FOR FAILURE TO VERIFY EXISTING FIELD CONDITIONS. DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR ALTERNATIVE METHODS OF INSTALLATION PRIOR TO THE BIDDING OF THIS PROJECT. 19. UNLESS OTHERWISE NOTED, ALL EXISTING MECHANICAL EQUIPMENT, PIPING, ETC, TO BE REMOVED SHALL BE DISPOSED OF BY THE CONTRACTOR UNDER THIS CONTRACT. THE OWNER SHALL RETAIN THE RIGHT TO KEEP ANY REMOVED ITEMS. 20. ALL DOMESTIC HOT AND COLD WATER LINES IN THE AREA OF WORK WHICH ARE NO LONGER IN USE DUE TO THIS PROJECT SHALL BE REMOVED BACK TO THE MAINS AND CAPPED. NO DEAD LEGS ALLOWED. 21. HOLES IN EXISTING WALLS OR FLOORS SHALL BE PATCHED TO MATCH EXISTING WHERE PIPING, DUCTWORK, ETC, WERE REMOVED OR ADDED DURING THIS PROJECT. 22. DAMAGE TO THE EXISTING FACILITY DURING THE CONSTRUCTION OF THIS PROJECT SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO COST THE OWNER. A.COMPLIANCE WITH THE LATEST ADOPTED EDITION OF THE INTERNATIONAL ENERGY CONSERVATION CODE IS REQUIRED FOR THIS PROJECT. THESE NOTES COVER MANDATORY REQUIREMENTS OF THE CODE. ADDITIONAL REQUIREMENTS ARE NOTED ON THE DRAWINGS AND IN THE SPECIFICATIONS. B.MINIMUM REQUIREMENTS FOR SUPPLY AND RETURN DUCTWORK INSULATION: 1. R-6: DUCTS LOCATED IN UNCONDITIONED SPACES (SPACE NEITHER HEATED NOR COOLED SUCH AS ABOVE CEILING SPACES, WALL SPACES, DUCT CHASES, SOFFITS, ATTICS, CRAWL SPACES, UNHEATED BASEMENTS, AND UNHEATED GARAGES). 2. R-12: DUCTS LOCATED OUTSIDE OF THE BUILDING'S INSULATION ENVELOPE (SUCH AS ABOVE THE ATTIC INSULATION). TYPICAL INSULATION THICKNESS REQUIRED TO MEET THESE REQUIREMENTS: 1. FIBERGLASS DUCT WRAP: R-6, R-12. 2. FIBERGLASS DUCT LINER: R-6, R-12. C.CONTRACTOR SHALL VERIFY THE R-VALUES OF THE ACTUAL INSULATION USED WITH THE MANUFACTURER. R-VALUES SHALL BE INSTALLED VALUES. D.WHERE DUCTS USED FOR COOLING ARE EXTERNALLY INSULATED, THE INSULATION SHALL BE COVERED WITH A VAPOR RETARDER HAVING A MAXIMUM PERMEANCE OF 0.05 PERM OR ALUMINUM FOIL HAVING A MINIMUM THICKNESS OF 2 MILS. INSULATION HAVING A PERMEANCE OF 0.05 PERMS OR LESS SHALL NOT BE REQUIRED TO BE COVERED. ALL JOINTS AND SEAMS SHALL BE SEALED TO MAINTAIN THE CONTINUITY OF THE VAPOR RETARDER. E.ALL DUCT JOINTS, SEAMS, AND CONNECTIONS SHALL BE FASTENED AND SEALED WITH WELDS, GASKETS, ADHESIVES, MASTIC-PLUS-EMBEDDED-FABRIC SYSTEMS, OR TAPES. TAPES AND MASTICS SHALL BE LISTED AND LABELED PER UL181A OR UL181B. DUCT TAPE IS NOT PERMITTED AS A SEALANT ON ANY METAL DUCTS. DUCT CONNECTIONS TO FLANGES OR EQUIPMENT SHALL BE SEALED AND MECHANICALLY FASTENED. F.MINIMUM REQUIREMENTS (THICKNESS) FOR PIPING INSULATION SHALL BE AS FOLLOWS: FLUID NOMINAL PIPE DIAMETER 1.REFRIGERANT SEE SPECIFICATIONS THE ABOVE INSULATION IS BASED ON HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU-INCH/HOUR-FT2-°F. G.DOMESTIC HOT WATER PIPING SYSTEMS SHALL BE INSULATED WITH 1" INSULATION HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU-INCH/HOUR-FT2-°F. H.AN OPERATING AND MAINTENANCE MANUAL SHALL BE PROVIDED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. THE O&M MANUAL SHALL CONTAIN THE FOLLOWING INFORMATION AS A MINIMUM: 1. EQUIPMENT CAPACITY (INPUT & OUTPUT). 2. EQUIPMENT OPERATING AND MAINTENANCE INSTRUCTIONS. 3. CONTROL SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCES. 4. CONTROL SYSTEM SETPOINTS SHALL BE SHOWN ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR IN PROGRAMMING COMMENT ON DDC SYSTEMS. 5. A COMPLETE WRITTEN NARRATIVE ON HOW EACH MECHANICAL SYSTEM IS INTENDED TO OPERATE. ENERGY CODE COMPLIANCE P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E MU S G R O V E E N G I N E E R I N G , P A 64 5 W . 2 5 T H S T . ID A H O F A L L S , I D 8 3 4 0 2 20 8 -52 3 -28 6 2 ww w . m u s g r o v e p a . c o m PR O J E C T N U M B E R : 2 3 -19 9 7/ 1 3 / 2 0 2 3 1 2 : 5 7 : 3 5 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 MECHANICAL COVER SHEET 23-010 DM TN 06/29/2023 M0.00 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 07/13/2023 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E MU S G R O V E E N G I N E E R I N G , P A 64 5 W . 2 5 T H S T . ID A H O F A L L S , I D 8 3 4 0 2 20 8 -52 3 -28 6 2 ww w . m u s g r o v e p a . c o m PR O J E C T N U M B E R : 2 3 -19 9 7/ 1 3 / 2 0 2 3 1 2 : 5 7 : 5 2 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 MECHANICAL SPECIFICATIONS 23-010 DM TN 06/29/2023 M0.01 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 07/13/2023 T TT 1A 1B 1D 2 E1ED2D1DC3C1 OFFICE 2 215 OFFICE 1 216 OFFICE 3 217GROUP ROOM 218 WAITING AREA 219 RECEPTION 220 FC 151 (FC-151) 6"ø - 80 D 1 6"Ø (E)FC 150 1 1 2 4 4 5(210 CFM) (100 CFM)(150 CFM) (175 CFM) 8"ø - 22"X10" R 9 (TYP. OF 2) 6 7 8 1A 1B 1D 2 E1ED2D1DC3C1 1 1 2 2 3 3 4 4 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E MU S G R O V E E N G I N E E R I N G , P A 64 5 W . 2 5 T H S T . ID A H O F A L L S , I D 8 3 4 0 2 20 8 -52 3 -28 6 2 ww w . m u s g r o v e p a . c o m PR O J E C T N U M B E R : 2 3 -19 9 7/ 1 3 / 2 0 2 3 1 2 : 5 7 : 5 3 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 MECHANICAL PLANS 23-010 DM TN 06/29/2023 M1.00 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 KEYED NOTES: SYMBOL USED FOR CALLOUT# 1/4" = 1'-0"M1.00 D4 HVAC NEW WORK PLAN 1/4" = 1'-0"M1.00 D1 HVAC DEMOLITION PLAN 1. REMOVE EXISTING CEILING DIFFUSER TEMPORARILY FOR CEILING REPLACEMENT. CLEAN AND REINSTALL IN NEW CEILING. BALANCE TO INDICATED AIRFLOW. 2. REMOVE EXISTING CEILING RETURN GRILLE TEMPORARILY FOR CEILING REPLACEMENT. CLEAN AND REINSTALL IN NEW CEILING WITH NEW FILTERS. 3. REMOVE EXISTING CEILING DIFFUSER AND RELATED DUCTWORK (AS INDICATED BY HATCH). REINSTALL EXISTING CEILING DIFFUSER IN NEW LOCATION AND BALANCE TO INDICATED AIRFLOW. EXTEND/TRIM/MODIFY DUCTWORK AS NECESSARY TO ACOMMODATE NEW LOCATION. 4. EXISTING AIR TERMINAL TO REMAIN. REBALANCE TO NEW AIRFLOW (IF APPLICABLE). 5. CLEAN AND REINSTALL RELOCATED EXISTING CEILING DIFFUSER IN NEW CEILING. BALANCE TO INDICATED AIRFLOW. 6. 22"X10" INTERNALLY LINED TRANSFER DUCT. REFER TO TRANSFER DUCT DETAIL FOR ADDITIONAL INFORMATION. 7. REBALANCE EXISTING FRESH AIR DUCT TO 70 CFM. 8. ROUTE NEW REFRIGERANT LINES BACK TO EXISTING BRANCH SELECTOR BOX (BS-14), THIS AREA. FIELD VERIFY EXISTING CONDITIONS, EXACT LOCATION, AND EXACT REQUIREMENTS. 07/13/2023 FIG. A 18 GA. BLADE MIN. 1/8" CLEARANCE ALL AROUND 19" TO 48" FIG. D FIG. B UP TO 18" 1/8" CLEARANCE ALL AROUND 22 GA. BLADE FIG. C ELEVATION, TWO BLADE ARRANGEMENT DUCT VOLUME DAMPER (SEE NOTE 1) WING NUT DAMPER ARM (SEE NOTE 4) DAMPER BLADE (SEE NOTE 3) ROUND DUCT ROD (SEE NOTE 2) 18" GAGE MINIMUM BLADE 6" TO 9" WIDE 1/2" ROD DUCT1/2" QUADRANT DUCT HEMMED EDGE3/8" QUADRANT 3/8" PIN NOTES: 1. FOR TAKE-OFFS LARGER THAN 12" DIAMETER, USE A FACTORY MANUFACTURED DAMPER. LOUVERS & DAMPERS, INC. MODEL CD-600 WITH A LOCKING HAND QUADRANT OR EQUAL. 2. ROD CONTINUOUS ON 2" W.G. CLASS AND ON ALL DAMPERS OVER 12" DIAMETER. 3. BLADE 22 GAGE MIN., BUT NOT LESS THAN TWO GAGES MORE THAN THE DUCT GAGE. 4. PROVIDE REMOTE CEILING OPERATOR WHERE DAMPER IS INACCESSIBLE. 5. FOR DUCTS OVER 12" HIGH USE MULTIPLE BLADE DAMPERS (SEE FIG. C). 6. ALTERNATE MANUFACTURERS INCLUDE: AMERICAN WARMING, SAFE-AIR/DOWCO, J&J, LOUVERS & DAMPERS, RUSKIN, NAILOR, ARROW UNITED, POTTORFF, & CESCO. 7. PROVIDE STAND-OFF FOR DAMPER ARMS LOCATED W/EXTERNAL INSULATION. STAND-OFF STAND-OFF STAND-OFF METAL FASTENERS: OMARK INSUL-PINS, DURO DYNE FASTENERS OR GRIP NAILS INSTALLED BY GRIP NAIL AIR HAMMER OR AUTO FASTENER EQUIP. DUCT LINER NOT MORE THAN 2" FROM EDGE OF LINER SPACING PER SMACNA (TYPICAL) ALL ENDS OF LINER TO BE COATED W/ ADHESIVE AND SHALL BE BUTTED FIRMLY TOGETHER DUCT LINER (TO BE ADHERED TO DUCT W/ 100% ADHESIVE SEE SPECIFICATIONS) PROVIDE SHEET METAL NOSING OR SLEEVE OVER ANY EXPOSED LINER WHICH FACES THE OPPOSITE DIRECTIONS AS THE AIRFLOW SHEET METAL DUCT TOP AND BOTTOM SECTION OF LINER SHALL OVERLAP THE SIDES SECTION AIR FLOW 1 X Y NOTES: 1. TAKE-OFFS SHOULD NOT BE INSTALLED CLOSER THAN TWO WIDTHS TO ELBOWS OR INTERSECTIONS. 2. SEE BALANCE DAMPER DETAIL. 3. X NOT LESS THAN Y. 4. FLEXIBLE DUCTWORK SHALL BE FLEXMASTER 8-M, THERMAFLEX M-KE OR AN APPROVED EQUAL. FLEXIBLE DUCTWORK SHALL BE INSULATED WITH A MINIMUM R VALUE OF 5. 5. RUN-OUT SHALL BE SAME SIZE AS COLLAR. 6. REFERENCE HVAC PLANS FOR REQUIRED BALANCE DAMPER LOCATIONS. RECTANGULAR OR ROUND DUCT (SEE PLAN FOR SIZE) LOCKING QUADRANT HANDLE OR REMOTE CEILING OPERATOR WHERE DAMPER IS INACCESSIBLE HIGH EFFICIENCY DUCT TAKE-OFF (SEE NOTES 1 & 3) STAND OFF SEE SECTION 1 RIGID ROUND DUCT OR DIFFUSER COLLAR NYLON OR STAINLESS STEEL CLAMP OVER INSULATION NYLON OR STAINLESS STEEL CLAMP OVER FLEX DUCT INSULATION (SEE NOTE 4) LISTED AND LABELED TAPE OR MASTIC PER UL181A OR UL181B FLEX DUCT (SEE NOTE 4) 2 #8 1" LONG PAN HEAD SHEET METAL SCREW THRU CEILING TRACK INTO DIFFUSER (TYP.) BALANCE DAMPER (SEE NOTE 2) SUSPEND ELBOW FROM STRUCTURE RIGID SHEET METAL DUCT (SEE PLAN FOR SIZE) PROVIDE PLASTIC ELBOW SUPPORT (THERMAFLEX FLEX-FLOW OR TITUS FLEX-RIGHT) ON ALL FLEX DUCT ELBOWS AT DIFFUSERS, SIZED TO FIT DUCT. ALTERNATE: CONTRACTOR MAY USE HARD DUCT ELBOW IN PLACE OF FLEXIBLE DUCT. INSULATED FLEX DUCT. MAX LENGTH 6'-0" (SEE NOTE 4) CEILING GRILLE SUSPENDED CEILING TRACK 45° 1.5" MINIMUM STEEL BAND 1.5" MINIMUM STEEL BAND OPTION 1 WIRE NOTES: 1. SUPPORT SYSTEM SHALL NOT DAMAGE, CRIMP, OR INHIBIT DUCT FREE AREA IN ANY WAY. 2. FLEXIBLE DUCT MUST NOT EXCEED 6'-0" FROM CONNECTION TO TERMINATION. 3. MAXIMUM LENGTH BETWEEN SUPPORTS MUST NOT EXCEED 3'-0" ON CENTER. 4. ATTACH BANDS OR WIRES TO SUPPORT STRUCTURE ABOVE. 5. FLEXIBLE DUCTWORK SHALL BE FLEXMASTER 1-M OR APPROVED EQUAL. 6. FLEXIBLE DUCTWORK SHALL BE INSULATED WITH A MINIMUM R-VALUE OF 6.0. 7. FLEXIBLE DUCTWORK IS FOR INDOOR USE ONLY. DO NOT INSTALL OR STORE PRODUCT WHERE EXPOSURE TO DIRECT SUNLIGHT CAN OCCUR. PROLONGED EXPOSURE TO SUNLIGHT MAY CAUSE DETERIORATION OF VAPOR BARRIER. 8. TERMINAL DEVICES SHALL BE SUPPORTED INDEPENDENTLY OF THE FLEXIBLE DUCTWORK. 9. REPAIR TURN OR DAMAGED VAPOR BARRIER/JACKET WITH DUCT TAPE LISTED AND LABELED TO UL 181B. IF INTERNAL CORE IS PENETRATED, REPLACE FLEXIBLE DUCTWORK. 10. AVOID BENDING DUCT ACROSS SHARP CORNERS OR INCIDENTAL CONTACT WITH METAL FIXTURES, PIPES, OR CONDUITS. 11. FLEXIBLE DUCTWORK SHALL NOT BE INSTALLED WITHIN 4 INCHES OF HOT EQUIPMENT (FURNACES, BOILERS, STEAM PIPES, ETC.) THAT IS ABOVE 250°F. 12. FLEXIBLE DUCTWORK SHALL NOT BE INSTALLED IN CONCRETE, BURIED BELOW GRADE, OR IN CONTACT WITH THE GROUND. 13. DO NOT INSTALL FLEXIBLE DUCTWORK IN EXPOSED CEILING AREA. OPTION 2 X X R=1.5X X 90° TURNING VANES X X R=1.5X X X X R=1.5X X X Y Y Z X 1.5X Z X Y X 6" Y+2 Y Y=3"-8", Z=3" Y=17"-24", Z=9" X Z Y X Y = 2X; Z = SEE PLANS Y Z X X Y X X Y Z X Z = X - Y (4" MIN.) X Y=9"-16", Z=6" Y=25" UP, Z=12" NOTE: 1. ALL DUCTWORK TRANSITIONS SHALL BE CONSTRUCTED AND INSTALLED TO SMACNA, SPECIFICATIONS, AND THE ABOVE NOTED STANDARDS. ANY DEVIATIONS SHALL BE COORDINATED WITH THE ENGINEER. WYE FITTINGOFFSETECCENTRIC TRANSITION CONCENTRIC TRANSITION 90° TEE FITTING CONICAL FITTING 90° TEE W/ OVAL TO ROUND TAP 45° LATERAL TAP RADIUS ELBOW 90° GORED ELBOW 5 GORE MITERED ELBOW W/ TURNING VANES 45° GORED ELBOW 3 GORE Ө = 15° MAXIMUM 20% MAX AREA REDUCTION Ө = 30° MAXIMUMX R=1.0X X X X X Ө = 45° MAXIMUM R=6" MIN. 1/4 Ө = 15° MAXIMUM X X X R=1.0X X X 1/2 1/4 R=6" MIN. X X Ө R.A. 90° TURNING VANES S.A. X Y 0.25Y, 4" MIN. X Y R=1.5X X Y X X+Y Y Y X X Z NOTE: 1. ALL DUCTWORK TRANSITIONS SHALL BE CONSTRUCTED AND INSTALLED TO SMACNA, SPECIFICATIONS AND THE ABOVE NOTED STANDARDS. ANY DEVIATIONS SHALL BE COORDINATED WITH THE ENGINEER. OBSTRUCTION REDUCTIONRADIUS OFFSETMITERED OFFSET45° ELBOW SQUARE ELBOW W/ TURNING VANES 90° ELBOW CONCENTRIC TRANSITION ECCENTRIC TRANSITION DUCT TAKE-OFF RADIUS WYE SQUARE TEE W/ TURNING VANES SQUARE TEE W/ DUCT TAKE-OFFS ӨӨ Ө Ө INTERNALLY LINED SHEET METAL TRANSFER DUCT WITH MINIMUM 1" THICK INSULATION. USE JOHNS MANSFIELD ACOUSTIC DUCT LINER TRANSFER GRILLE (TYPICAL)CEILING PARTITION WALL SEE PLANS FOR SIZES P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E MU S G R O V E E N G I N E E R I N G , P A 64 5 W . 2 5 T H S T . ID A H O F A L L S , I D 8 3 4 0 2 20 8 -52 3 -28 6 2 ww w . m u s g r o v e p a . c o m PR O J E C T N U M B E R : 2 3 -19 9 7/ 1 3 / 2 0 2 3 1 2 : 5 7 : 5 3 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 MECHANICAL DETAILS 23-010 DM TN 06/29/2023 M2.00 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 NTSM2.00 C2 BALANCE DAMPER DETAIL NTSM2.00 E2 DUCT LINER DETAIL NTSM2.00 C5 DUCT TAKEOFF DETAIL - HIGH EFFICIENT NTSM2.00 C4 FLEXIBLE DUCT SUPPORT DETAIL NTSM2.00 E4 ROUND DUCT FITTING DETAILS NTSM2.00 E5 RECTANGULAR DUCT FITTING DETAILS NTSM2.00 D2 TRANSFER DUCT DETAIL 07/13/2023 VRF HVAC SYSTEM SCHEDULE OUTDOOR UNITS SYMBOL AREA SERVED NOMINAL TONS UNIT TYPE COOLING REQUIRED AT 80°F EDB, 67°F EWB HEATING REQUIRED AT 70°F EAT ELECTRICAL MINIMUM SEER OPER. WEIGHT (LBS) MANUFACTURER AND MODEL REMARKS TOTAL MBH SENSIBLE MBH TOTAL MBH MCA MOCP V/Ø HR-1(E)1ST FLOOR (EXISTING UNIT) 28 HEAT RECOVERY EXISTING UNIT TO REMAIN - FOR REFERENCE ONLY DAIKIN MODEL REYQ336PBYD EXISTING TO REMAIN INDOOR BRANCH SELECTOR UNITS SYMBOL AREA SERVED CONNECTED OUTDOOR UNIT RATED COOLING CAPACITY NUMBER OF PORTS ELECTRICAL MANUFACTURER AND MODEL REMARKS MCA MOCP V / Ø BS-14(E)1ST FLOOR NORTH (EXISTING UNIT)HR-1(E)EXISTING TO REMAIN - FOR REFERENCE ONLY DAIKIN MODEL BS8Q54TVJ EXISTING TO REMAIN INDOOR FAN COIL UNITS FAN COIL UNIT SYMBOL HEAT PUMP SYMBOL BRANCH SELECT SYMBOL AREA SERVED NOMINAL TONS UNIT TYPE SUPPLY FAN COOLING HEATING ELECTRICAL OSA SOUND (dB) OPER. WEIGHT (LBS) MANUFACTURER AND MODEL REMARKS CFM H/L MBH MBH MCA MOCP V/Ø FC-150(E)HR-1(E)BS-14(E) BEHAVIORAL HEALTH CLINIC 1.6 SLIM DUCTED 636 / 530 18.0 20.0 1.6 15 208/1 SEE PLANS EXISTING TO REMAIN DAIKIN MODEL FXMQ (EXISTING TO REMAIN)EXISTING TO REMAIN FC-151(N)HR-1(E)BS-14(E)GROUP ROOM 218 1.5 CEILING CASSETTE 511 / 353 18.0 20.0 0.6 15 208/1 N/A 43 50 DAIKIN MODEL FXZQ18TAVJU 1 , 2 , 3 , 4 , 5 REMARKS: 1. APPROVED ALTERNATE MANUFACTURERS: NONE. 2. CONTROL UNIT WITH MANUFACTURER'S HARD-WIRED WALL CONTROLLER WITH AUTO CHANGEOVER. 3. PROVIDE WITH CONDENSATE PUMP. 4. ELECTRICAL TO PROVIDE DISCONNECT. 5. PROVIDE ISOLATION VALVES ON REFRIGERANT LINES FROM BRANCH SELECTOR UNIT. DIFFUSER SCHEDULE SYMBOL NOMINAL SIZE NECK / RUNOUT SIZE CFM RANGE REMARKS 6X6 6"Ø 0 - 90 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 9X9 8"Ø 90 - 200 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 12X12 10"Ø 200 - 350 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 15X15 12"Ø 300 - 500 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 15X15 14"Ø 400 - 650 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 18X18 16"Ø 600 - 900 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 21X21 21X21 900 - 1400 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 6"Ø CFM D-1 8"Ø CFM D-2 10"Ø CFM D-3 12"Ø CFM D-4 14"Ø CFM D-5 16"Ø CFM D-6 21X21 CFM D-7 REMARKS: 1. ALTERNATE MANUFACTURERS: ANEMOSTAT, J&J REGISTER, NAILOR, METAL-AIRE, TUTTLE & BAILEY, KRUEGER, PRICE, AND UNITED ENERTECH. 2. SIZES BASED ON TITUS MODEL TDC SERIES. 3. SIZES BASED ON A MAXIMUM NC LEVEL OF 25. 4. ALL DIFFUSERS LOCATED IN LAY-IN CEILING AREAS SHALL BE BORDER TYPE 3 AND BE MOUNTED IN MANUFACTURER PROVIDED 24"x24" PANELS. ALL DIFFUSERS LOCATED IN HARD CEILING AREAS SHALL BE BORDER TYPE 6 (BEVELED) SURFACE MOUNTED. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF VARIOUS CEILING TYPES. 5. SEE HVAC FLOOR PLANS FOR DIRECTIONAL THROW REQUIREMENTS FOR EACH DIFFUSER. 6. ALL OF THE DIFFUSERS SHOWN IN THIS SCHEDULE MAY NOT BE USED. REFERENCE THE HVAC PLAN FOR DIFFUSER CALL-OUTS AND THE QUANTITY OF EACH SIZE REQUIRED. 7. WHENEVER THERE IS A DISCREPANCY BETWEEN THE RUNOUT DUCT SIZE SHOWN ON THE PLANS AND THAT SHOWN IN THE SCHEDULE, ALWAYS USE THE LARGER OF THE TWO DUCT SIZES. 8. COLOR TO BE SELECTED BY ARCHITECT. RETURN & EXHAUST GRILLE SCHEDULE SYMBOL NOMINAL SIZE NECK / RUNOUT SIZE CFM RANGE REMARKS 8X8 6"Ø 0-80 1 , 2 , 3 , 4 , 5 , 6 , 7 10X10 8"Ø 80-180 1 , 2 , 3 , 4 , 5 , 6 , 7 12X12 10"Ø 180-300 1 , 2 , 3 , 4 , 5 , 6 , 7 22X10 6"Ø 0-80 1 , 2 , 3 , 4 , 5 , 6 , 7 22X10 8"Ø 80-180 1 , 2 , 3 , 4 , 5 , 6 , 7 22X10 10"Ø 180-300 1 , 2 , 3 , 4 , 5 , 6 , 7 22X22 12"Ø 300-500 1 , 2 , 3 , 4 , 5 , 6 , 7 22X22 14"Ø 500-750 1 , 2 , 3 , 4 , 5 , 6 , 7 22X10 22X10 500-1100 1 , 2 , 3 , 4 , 5 , 6 , 7 22X22 22X22 1100-2000 1 , 2 , 3 , 4 , 5 , 6 , 7 REMARKS: 1. ALTNERNATE MANUFACTURERS: ANEMOSTAT, CARNES, PRICE, NAILOR, METAL-AIRE, TUTTLE & BAILEY, KRUEGER, J&J REGISTER, AND UNITED ENERTECH. 2. SIZES BASED ON TITUS MODEL 50F, ALUMINUM EGGCRATE RETURN GRILLE, 1/2" x 1/2" x 1" SPACING (SINGLE CORE). PROVIDE SQUARE TO ROUND TRANSITION (WHERE ROUND RUN-OUT INDICATED). 3. SIZES BASED ON A MAXIMUM NC LEVEL OF 25. 4. ALL GRILLES LOCATED IN LAY-IN CEILING AREAS SHALL HAVE BORDER #3, UNLESS OTHERWISE INDICATED. ALL GRILLES LOCATED IN HARD CEILING AREAS SHALL HAVE BORDER #1, UNLESS OTHERWISE INDICATED. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF VARIOUS CEILING TYPES. SHEET METAL DUCTWORK VISIBLE BEHIND GRILLE SHALL BE PAINTED FLAT BLACK. 5. ALL OF THE GRILLES SHOWN IN THIS SCHEDULE MAY NOT BE USED. REFERENCE THE HVAC PLAN FOR GRILLE CALL-OUTS AND THE QUANTITY OF EACH SIZE REQUIRED. 6. WHENEVER THERE IS A DISCREPANCY BETWEEN THE RUNOUT DUCT SIZE SHOWN ON THE PLANS AND THAT SHOWN IN THE SCHEDULE, ALWAYS USE THE LARGER OF THE TWO DUCT SIZES. 7. COLOR TO BE SELECTED BY ARCHITECT. 6"Ø R-1 8"Ø R-2 10"Ø R-3 6"Ø R-4 8"Ø R-5 10"Ø R-6 12"Ø R-7 14"Ø R-8 22X10 R-9 22X22 R-10 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E MU S G R O V E E N G I N E E R I N G , P A 64 5 W . 2 5 T H S T . ID A H O F A L L S , I D 8 3 4 0 2 20 8 -52 3 -28 6 2 ww w . m u s g r o v e p a . c o m PR O J E C T N U M B E R : 2 3 -19 9 7/ 1 3 / 2 0 2 3 1 2 : 5 7 : 5 3 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 MECHANICAL SCHEDULES 23-010 DM TN 06/29/2023 M3.00 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 07/13/2023 S-1 PLUMBING FIXTURE SCHEDULE SYMBOL FIXTURE DESCRIPTION CONNECTION SIZE MANUFACTURER / MODEL NUMBER / DESCRIPTION / ADDITIONAL COMMENTS WASTE VENT TRAP CW HW SINK - CLINICAL / EXAM (9" X 12" X 6") (ADA COMPLIANT) 1-1/2 1-1/2 1-1/2 1/2 1/2 ELKAY MODEL BLR1560: 6" DEEP, STAINLESS STEEL SINK. PROVIDE AND INSTALL CHICAGO FAUCETS MODEL 895-317GN2AFCXKABCP MANUAL FAUCET WITH 4" FIXED CENTERS, SWING SPOUT, NON-AERATING LAMINAR FLOW CONTROL IN BASE OF SPOUT, AND 4" WRISTBLADES. PROVIDE WITH ELKAY MODEL LK35 STAINLESS STEEL STRAINER BASKET AND TAILPIECE, AND WATTS SERIES LFUSG-B LEAD-FREE, THERMOSTATIC MIXING VALVE, ASSE STANDARD 1070 LISTED, BRONZE BODY, INTEGRAL CHECK VALVES, AND SELECTABLE TEMPERATURE RANGE FROM 80°F TO 120°F. NOTES: 1. ALL ADA COMPLIANT FIXTURES MUST COMPLY WITH ICC/ANSI A117.1. SEE ARCHITECTURAL PLANS FOR HANDICAPPED FIXTURE DESIGNATIONS, LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS. 2.ALL EXPOSED HW PIPING, CW PIPING, AND DRAIN LINES BENEATH ALL LAVATORIES AND ALL ADA COMPLIANT SINKS MUST BE INSULATED TO PREVENT INJURY. REFER TO ARCHITECTURAL PLANS. INSULATE WITH MOLDED CLOSED CELL VINYL INSULATION - TRUEBRO, PLUMBEREX, OR EQUAL. 3. SEE SPECIFICATIONS FOR ALTERNATE APPROVED MANUFACTURERS. 1A 1B 1D 2 E1ED2D1DC3C1 OFFICE 2 215 OFFICE 1 216 OFFICE 3 217 GROUP ROOM 218 WAITING AREA 219 RECEPTION 220 FC 151 (E)FC 150 3 3 1 2 S-1 1 1/2"ø SW 4 NOTES: A. INTERIOR EXPOSED PIPE, VALVES AND FIXTURE TRIM, INCLUDING TRIM BEHIND CASEWORK DOORS SHALL BE CHROME PLATED. B. ALL PIPING PENETRATIONS THROUGH FINISHED WALLS SHALL BE PROVIDED WITH CHROME ESCUTCHEONS. C. ALL SINK TRAPS SHALL BE PROVIDED WITH A CLEANOUT PLUG IN THE BOTTOM OF THE TRAP. D. ALL PLUMBING FIXTURES SHALL BE CAULKED AND SEALED TO SURROUNDING SURFACES. SEE PLUMBING FIXTURE SCHEDULE FOR BOWL & FAUCET SPECIFICATIONS CHROME PLATED COPPER TUBING WATER RISERS OTHER PIPING MATERIALS, SEE SPECIFICATIONS CHROME PLATED PIPING AND FITTINGS, TYPICAL ALL PIPING BELOW SINKS AND LAVATORIES, SEE NOTES BELOW CLEANOUT PLUG CHROME ESCUTCHEON NOTES: 1. INTERIOR EXPOSED PIPE, VALVES AND FIXTURE TRIM, INCLUDING TRIM BEHIND CASEWORK DOORS, SHALL BE CHROME PLATED. 2. ALL PIPING PENETRATIONS THROUGH FINISHED WALLS SHALL BE PROVIDED WITH CHROME ESCUTCHEONS. 3. ALL SINK AND LAVATORY TRAPS SHALL BE PROVIDED WITH A CLEANOUT PLUG IN THE BOTTOM OF THE TRAP. 4. ALL PLUMBING FIXTURES SHALL BE CAULKED AND SEALED TO SURROUNDING SURFACES. 5. PLUMBING CONTRACTOR SHALL VERIFY THE LOCATION OF ALL LAVATORIES AND SINKS THAT NEED TO BE INSTALLED WITH THE BRANCH TAIL PIECE SECTION WITH 3/4" DRAIN CONNECTION. THE PLUMBING CONTRACTOR WILL BE RESPONSIBLE TO VERIFY THE PLUMBING ROUGH-IN DIMENSIONS AND SHALL TAKE INTO ACCOUNT THE TAIL PIECE EXTENSION DIMENSIONS. OTHER PIPING MATERIALS. SEE SPECIFICATIONS CHROME PLATED COPPER TUBING WATER RISERS TYPICAL CONDENSATE DRAIN CONNECTION INTO LAVATORY AND SINK DRAIN PIPING, SEE MECHANICAL FLOOR PLANS FOR FAN COIL CONNECTIONS, SIZES AND PIPING ROUTES CLEANOUT PLUG CHROME ESCUTCHEON BRANCH TAIL PIECE EXTENSION SECTION WITH 3/4" CONDENSATE DRAIN CONNECTION (PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR) CHROME PLATED PIPE AND FITTINGS, TYPICAL ALL PIPING BELOW SINKS AND LAVATORIES, SEE NOTES BELOW SEE PLUMBING FIXTURE SCHEDULE FOR BOWL & FAUCET SPECIFICATIONS P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E MU S G R O V E E N G I N E E R I N G , P A 64 5 W . 2 5 T H S T . ID A H O F A L L S , I D 8 3 4 0 2 20 8 -52 3 -28 6 2 ww w . m u s g r o v e p a . c o m PR O J E C T N U M B E R : 2 3 -19 9 7/ 1 3 / 2 0 2 3 1 2 : 5 7 : 5 4 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 PLUMBING PLAN 23-010 DM TN 06/29/2023 P1.00 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 KEYED NOTES: SYMBOL USED FOR CALLOUT# 1. TIE NEW SANITARY WASTE LINE INTO EXISTING WASHER BOX DRAIN PIPE IN WALL ABOVE GRADE, THIS AREA. FIELD VERIFY EXISTING CONDITIONS AND EXACT REQUIREMENTS. COORDINATE GWB ACCESS AND PIPE ROUTING WITH ARCHITECTURAL. 2. ROUTE VENT PIPING AS NECESSARY TO CONNECT TO EXISTING VENT SYSTEM SERVING EXISTING WASHER BOX, THIS AREA. FIELD VERIFY EXISTING CONDITIONS AND EXACT LOCATION. COORDINATE GWB ACCESS WITH ARCHITECTURAL. 3. ROUTE DOMESTIC WATER PIPING AS NECESSARY TO CONNECT TO EXISTING DOMESTIC WATER SYSTEM SERVING EXISTING WASHER BOX. FIELD VERIFY EXISTING CONDITIONS AND EXACT LOCATION. COORDINATE GWB ACCESS WITH ARCHITECTURAL. 4. ROUTE CONDENSATE DRAIN TO TAILPIECE OF NEARBY EXISTING SINK. FIELD VERIFY EXISTING CONDITIONS AND EXACT ROUTING. REFER TO SINK/LAVATORY TAILPIECE DETAIL W/ CONDENSATE FOR ADDITIONAL INFORMATION. 1/4" = 1'-0"P1.00 D4 PLUMBING PLAN NTSP1.00 B2 SINK/LAVATORY TAILPIECE & TRAP DETAIL NTSP1.00 D2 SINK/LAVATORY TAILPIECE & TRAP DETAIL (W/ CONDENSATE) 07/13/2023 M S J J HC F C C M SS SOS 2 J J J J J J D TC PC OS S K CR M M S TV TV SP SP V IC H T F F F F F F F EOL FS TS PS PIV DH R CM MM F F F T F # SD F EG J 100A 3P - BLACK - RED - BLUE - WHITE - GREEN PHASE A PHASE B PHASE C NEUTRAL GROUND - BROWN - ORANGE - YELLOW - GRAY - GREEN PHASE A PHASE B PHASE C NEUTRAL GROUND 208Y/120 VOLT SYSTEM 480Y/277 VOLT SYSTEM ELECTRICAL LEGEND - LIGHTING DEVICES ONE LINE SECURITY A AMPERES AC 6" ABOVE BACKSPLASH AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AF AMP FRAME AIC AMPS INTERRUPTING CAPACITY AT AMP TRIP ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BD BOTTOM OF DECK BS BOTTOM OF STRUCTURE C CEILING MOUNTED C CONDUIT CB CIRCUIT BREAKER CF COMPACT FLUORESCENT CKT CIRCUIT CO CONDUIT ONLY, PROVIDE PULL-LINE CT CURRENT TRANSFORMER CTL CONTROL DC DIRECT CURRENT (D) DEMOLITION DEMO DEMOLITION DET DETAIL DTT DOUBLE TWIN TUBE E EMERGENCY (E) EXISTING EC ELECTRICAL CONTRACTOR EL EMERGENCY LIGHT F FUSE (F) FUTURE FACP FIRE ALARM CONTROL PANEL G/GND GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER HH HAND HOLE HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTO HPS HIGH PRESSURE SODIUM HVAC HEATING, VENTILATION, & AIR CONDITIONING IG ISOLATED GROUND IPCO IDAHO POWER COMPANY J-BOX JUNCTION BOX KA KILOAMP KVA KILO VOLT-AMP KW KILOWATT KWH KILOWATT HOUR LCP LIGHTING CONTROL PANEL MB MAIN BREAKER MBR MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MLO MAIN LUGS ONLY MMC MODULAR METERING CENTER MH METAL HALIDE MSB MAIN SWITCH BOARD MTG MOUNTING N NEUTRAL (N) NEW NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NIC NOT IN CONTRACT NL NIGHT LIGHT NO NORMALLY OPEN NTS NOT TO SCALE OH OVERHEAD OS OCCUPANCY SENSOR P POLES PC PHOTO-CONTROL PVC POLYVINYL CHLORIDE PWR POWER RE: REFERENCE REC RECEPTACLE (R) RELOCATED SF SQUARE FEET TBD TO BE DETERMINED TDR TIME DELAY RELAY TK TOE KICK TSP TWISTED SHIELDED PAIR TRT TRIPLE TUBE TTB TELEPHONE TERMINAL BOARD (TYP.) TYPICAL UC UNDERCABINET UG UNDERGROUND U.N.O. UNLESS NOTED OTHERWISE V VOLT VA VOLT-AMPERE W WATT WG WIRE GUARD WP WEATHER PROOF/NEMA 3R ELECTRICAL ABBREVIATIONS PROVIDED/ PROVIDE BY INSTALLED/ INSTALL PROVIDE AND INSTALL / PROVIDED AND INSTALLED BY / PROVIDE AND INSTALL NOTE: THIS IS A STANDARD LIST OF COMMONLY USED ELECTRICAL ABBREVIATIONS. SOME OF THE ABBREVIATIONS SHOWN ABOVE MAY NOT BE USED IN THIS DRAWING PACKAGE. CIRCUITING SYMBOLS ELECTRICAL SPECIFICATIONS COMMUNICATIONS ELECTRICAL GENERAL NOTES FIRE ALARM X X OS D REB (unit-#) (unit-#) DUAL LEVEL SWITCHING, INSIDE AND OUTSIDE LAMPS OF FIXTURE TO BE SWITCHED SEPARATELY. INDIVIDUAL BREAKER WITH SHUNT TRIP, SIZE AND POLES INDICATED. NEMA 1 UNO INDIVIDUAL BREAKER, SIZE AND POLES INDICATED. NEMA 1 UNO +80" #P ##A #P ##A ##A ##A #P T REFERENCE FIXTURE SCHEDULE FOR MOUNTING TYPE, MOUNTING HEIGHT, AND FIXTURE TYPE. ##A #P DOUBLE FACE EXIT SIGN, CEILING MOUNTED, PROVIDE UNSWITCHED CONDUCTOR. WALL MOUNTED DOUBLE FACE EXIT SIGN PROVIDE UNSWITCHED CONDUCTOR. MOUNT AT +8'-0" UNO. WALL MOUNTED SINGLE FACE EXIT SIGN PROVIDE UNSWITCHED CONDUCTOR. MOUNT AT +8'-0" UNO. ARROW INDICATES DIRECTION TO BE SHOWN ON SIGN. 1'X1' LIGHT FIXTURE. 1'X1' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. 1'X4' LIGHT FIXTURE. 1'X4' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. 2'X4' LIGHT FIXTURE. 2'X4' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. 2'X2' LIGHT FIXTURE. 2'X2' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. DIRECT/INDIRECT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. DIRECT/INDIRECT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR STRIP LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. STRIP LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR WALL MOUNTED LIGHT FIXTURE. WALL MOUNTED LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. RECESSED LIGHT FIXTURE RECESSED LIGHT FIXTURE. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. ROUND LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE. POLE LIGHT 1 HEAD WITH POLE TIME CLOCK PHOTO CONTROL CELL LOCATED 12" ABOVE ROOF FACING NORTH. EMERGENCY EGRESS LIGHTING. CONNECT TO AN UNSWITCHED CONDUCTOR. INDICATES FIXTURE TYPE. REFER TO FIXTURE SCHEDULE. EXTERIOR WALL PACK EMERGENCY EXTERIOR WALL PACK. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR SWITCH, TYPE AS INDICATED. +46"AFF OCCUPANCY SENSOR. PROVIDE RELAYS AND POWER PACKS AS REQUIRED. SINGLE CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNT SINGLE CONVENIENCE OUTLET DUPLEX CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNT DUPLEX CONVENIENCE OUTLET EMERGENCY DUPLEX CONVENIENCE OUTLET, +18" AFF UNO SWITCHED DUPLEX CONVENIENCE OUTLET, +18" AFF UNO FLOOR MOUNTED SWITCHED DUPLEX CONVENIENCE OUTLET FOURPLEX CONVENIENCE OUTLET. +18"AFF UNO FLOOR MOUNT FOURPLEX CONVENIENCE OUTLET CONNECTION POINT TO EQUIPMENT SPECIFIED, ELECTRICAL CONTRACTOR TO SUPPLY RACEWAY AND CONDUCTORS AND MAKE FINAL CONNECTION TO EQUIPMENT UNDER THIS SECTION. UNO FLOOR MOUNTED CONNECTION POINT, SEE NOTE ABOVE FOR REQUIREMENTS JUNCTION BOX WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO WALL MOUNTED PUSH BUTTON, HANDICAPPED MOUNT AT SWITCH HEIGHT UNO WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO MOTOR STARTER/CONTACTOR, SIZE/POLES NEMA 1 UNO AS INDICATED COMBINATION STARTER AND DISCONNECT, SIZE/POLES, STARTER SIZE AS INDICATED, NEMA 1 UNO MECHANICAL EQUIPMENT CALL OUT SURFACE MULTI-OUTLET RACEWAY EQUIPMENT CABINET FLUSH MOUNTED EQUIPMENT CABINET, SURFACE MOUNTED PANELBOARD. SEE SCHEDULE FOR TYPE. TRANSFORMER POWER POLE - DUAL CHANNEL THERMOSTAT, +46" AFF PROVIDE CONDUIT, J-BOX, CONDUCTORS AS REQUIRED TO CONTROL ASSOCIATED UNITS. UNO COORDINATE WITH DIVISION 15. NON-FUSED DISCONNECT SIZE/ POLES AS INDICATED, NEMA 1 UNO FUSED DISCONNECT SWITCH, SIZE/POLES, FUSE SIZES AS INDICATED, NEMA 1 UNO DELTA WYE TRANSFORMER UNO PANEL BOARD, SEE SCHEDULE FOR TYPE AND SIZE CIRCUIT BREAKER, SIZE AND POLES INDICATED FUSE, SIZE AND TYPE INDICATED, PROVIDE FUSE FOR EACH POLE INTERRUPTER SWITCH, SIZE AND POLES INDICATED FUSED SWITCH, SIZE/POLES AND FUSE SIZE INDICATED DRAW OUT CIRCUIT BREAKER, SIZE AND POLES INDICATED GROUND FAULT PROTECTION TRANSIENT VOLTAGE SURGE SUPPRESSION NEUTRAL METER AND BASE AUTOMATIC TRANSFER SWITCH (ATS) GENERATOR SET, MAIN BREAKER SIZE INDICATED OVERHEAD SERVICE DROP DISCONNECT SWITCH, SIZE AND POLES INDICATED. NEMA 1 UNO MOTOR SHUNT TRIP COIL PAD MOUNT TRANSFORMER DRY TYPE TRANSFORMER CCTV CAMERA POWER SUPPLY CCTV SYSTEM POWER SUPPLY ADJUSTABLE CAMERA (PAN/TILT/ZOOM) FIXED CAMERA CAMERA IN OUTDOOR HOUSING ADJUSTABLE CAMERA (PAN/TILT/ZOOM) IN OUTDOOR HOUSING CCTV OUTLET, +18" UNO CEILING MOUNTED CCTV OUTLET SECURITY SYSTEM KEYPAD CONTROLLER COORDINATE BOX SIZE AND MUDRING WITH VENDOR CEILING MOUNTED MOTION SENSOR WALL MOUNTED MOTION SENSOR, MOUNTING HEIGHT INDICATED PANIC BUTTON - MOUNTED UNDER COUNTER KITCHEN EQUIPMENT CALLOUT TRACK LIGHT FLOOR MOUNTED JUNCTION BOX ADJUSTABLE BREAKER SETTINGS (PER SPECIFICATIONS): 'L'-LONG TIME 'S'-SHORT TIME 'I'-INSTANTANEOUS 'G'-GROUND FAULT 'R'-ENERGY REDUCING MAINTENANCE SWITCH W/STATUS INDICATOR EMERGENCY EGRESS LIGHTING WITH OUT FIXTURE HEADS. CONNECT TO AN UNSWITCHED CONDUCTOR. CARD READER 2 DOUBLE POLE 3 3-WAY 4 4-WAY K KEYED P PILOT LIGHT D DIMMER HP HORSEPOWER RATED TO THERMAL OVERLOAD LV LOW VOLTAGE OS OCCUPANCY SENSOR OR LOW VOLTAGE, MOMENTARY OVERRIDE VS VACANCY SENSOR a SUPERSCRIPT INDICATES LIGHTS TO BE SWITCHED TOGETHER XXX GROUNDROUND EMERGENCY LIGHT FIXTURE. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. WALL MOUNTED EMERGENCY LIGHT FIXTURE. PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR. DUAL LEVEL SWITCHING WITH OCCUPANCY SENSOR, INSIDE AND OUTSIDE LAMPS OF FIXTURE TO BE SWITCHED SEPARATELY. EXISTING CONDUIT DOWN CONDUIT UP 6 NEUTRAL CONDUCTORS GROUNDING CONDUCTOR SIZE QUANTITY 1"-4#10,1#10G PANEL HOMERUN. (3/4"-2#12,1#12G CONDUCTORS UNO) RACEWAY A-2,4,6 PANEL NAME CIRCUIT # EM NOTE: CURRENT CARRYING CONDUCTORS LED DRIVER T A. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE LOCALLY ADOPTED ELECTRICAL CODE, ALL LOCAL CODES, AND TO THE FULL ACCEPTANCE OF THE AUTHORITY HAVING JURISDICTION. B. OBTAIN ALL PERMITS, COORDINATE, FURNISH, INSTALL, CONNECT AND TEST ALL ELECTRICAL EQUIPMENT REQUIRED FOR ALL THE SYSTEMS INSTALLED UNDER THIS CONTRACT TO INSURE COMPLETE AND FULLY OPERATIONAL SYSTEMS. C. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS-BUILT DRAWINGS. AS-BUILT SET OF DRAWINGS SHALL BE UPDATED DAILY AND SHALL DOCUMENT THE ACTUAL INSTALLED CONDITION OF THE ENTIRE ELECTRICAL INSTALLATION. AS-BUILT SET OF DRAWINGS SHALL BE AVAILABLE AT ALL TIMES ON THE SITE FOR INSPECTION BY CODE OFFICIALS, OWNER, ARCHITECT, AND ENGINEER. D. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. E. DESIGN IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS TO DETERMINE STATUS OF ACTUAL CONDITIONS AS THEY RELATE TO THE SCOPE OF WORK AS SHOWN ON THESE PLANS. F. COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER TRADES. G. COORDINATE EXACT LOCATION AND MOUNTING HEIGHTS OF ALL ELECTRICAL EQUIPMENT AND DEVICES WITH THE ARCHITECTURAL ELEVATIONS AND DETAILS PRIOR TO ROUGH-IN. H. DEMOLITION WORK IS A PART OF THIS PROJECT. SEE DRAWINGS FOR EXISTING ELECTRICAL DEVICES TO BE REMOVED. REMOVE ASSOCIATED BOXES, RACEWAYS AND CONDUCTORS BACK TO SOURCE, AND MAKE SAFE. I. ALL MATERIALS AND EQUIPMENT FURNISHED TO THE PROJECT SHALL BE NEW AND SHALL BEAR THE LISTING LABEL OF A NATIONALLY RECOGNIZED TESTING LAB AS DEFINED BY OSHA. J. ALL ELECTRICAL DEVICES AND TERMINALS SHALL BE RATED 75°C MINIMUM. K. ALL CONDUCTORS SHALL BE STRANDED COPPER, 600 VOLT RATED. INSULATION TYPE SHALL BE THHN/THWN, FULLY COLOR CODED WITH GAUGE, TYPE AND MANUFACTURER MARKED EVERY 24" ALONG. CONDUCTOR COLOR CODE SHALL BE AS FOLLOWS: L. MINIMUM SIZE WIRE FOR POWER AND LIGHTING CIRCUITS SHALL BE #12 AWG. ALL POWER AND LIGHTING CONDUCTORS SHALL BE ROUTED IN 3/4" CONDUIT MINIMUM. M. EMT OR MC TYPE CABLE IS ALLOWED WHEN CONCEALED IN INTERIOR SPACES. MC TYPE CABLE IS NOT ALLOWED FOR HOMERUNS. N. MAKE ALL CONNECTIONS TO EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. O. ALL EQUIPMENT, SWITCHING DEVICES AND PANELS SHALL BE MOUNTED SO AS TO BE ACCESSIBLE AND SHALL BE MOUNTED PLUMB AND SQUARE WITH WALLS. P. DEVICES AND RACEWAYS PENETRATING FIRE RATED WALLS AND FLOORS SHALL BE SEALED WITH FIRE RESISTIVE MATERIAL, COMPATIBLE WITH CONSTRUCTION PENETRATED, TO MAINTAIN RATING OF THE WALL. SEALANT SYSTEM SHALL BE A U.L. APPROVED SYSTEM AND INSTALLED PER MANUFACTURER'S INSTRUCTIONS. Q. FURNISH AND INSTALL PULL CORD IN ALL EMPTY CONDUITS. R. ALL JUNCTION BOX COVERS WITH POWER WIRING SHALL HAVE THE PANEL AND CIRCUIT LABELED ON THE OUTSIDE SURFACE. ALL LABELS FOR EXPOSED JUNCTION BOXES IN "FINISHED AREAS" SHALL BE LABELED UTILIZING SELF ADHESIVE LABELS PRODUCED BY A MECHANICAL LABELING MACHINE. LABELS FOR JUNCTION BOX COVERS IN CONCEALED LOCATIONS SHALL CONSIST OF THE INFORMATION BEING NEATLY HANDWRITTEN ON THE OUTSIDE SURFACE OF THE COVER WITH A PERMANENT STYLE MARKER. S. CLEARLY LABEL ALL ACCESSIBLE CONDUIT STUBS WITH SYSTEM NAME AND LOCATION (ROOM NUMBER) WHERE THE OTHER END OF THE CONDUIT TERMINATES. USE INDELIBLE INK. THE LABELS SHALL BE LOCATED ON THE CONDUIT IN A POSITION THAT CAN BE EASILY READ. T. ALL 1 POLE BREAKER CIRCUITS SHALL HAVE AN INDEPENDENT NEUTRAL CONDUCTOR. NO EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE ALLOWED. U. ALL CONDUCTORS IN ELECTRICAL PANELS, CABINETS AND EQUIPMENT SHALL BE NEATLY TRAINED AND LACED. V. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL PANELS. DIRECTORIES SHALL BE TYPED. W. PROVIDE ELECTRICAL SUBMITTALS FOR EQUIPMENT SHOWN AS REQUIRED BY DIVISION 1 SPECIFICATIONS. X. ELECTRICAL CONTRACTOR SHALL OBTAIN THE AVAILABLE FAULT CURRENT VALUE FROM THE LOCAL UTILITY OR THE ONE-LINE DIAGRAM AND LABEL THE MAIN BREAKER WITH THAT VALUE. Y. SWITCH AND RECEPTACLE LABELING: IDENTIFY PANELBOARD AND CIRCUIT NUMBER FROM WHICH DEVICES ARE SERVED. USE MACHINE PRINTED LABEL AND 1/8" TEXT. INSTALL ON THE OUTSIDE OF THE FACEPLATE FOR RECEPTACLES AND INSIDE THE FACEPLATE FOR SWITCHES. OCCUPANCY SENSOR WITH MANUAL DIMMING, SET FOR 50% AUTOMATIC ON, AUTOMATIC OFF, WITH MANUAL DIMMING. DESIGNATES CIRCUIT ON EMERGENCY SOURCE UNMARKED CIRCUIT IS CONCEALED IN CEILING OR WALL. MAINTAIN CONDUIT AND CONDUCTOR SIZE THROUGHOUT ENTIRE CIRCUIT. BEGINNING OF INDIVIDUAL CIRCUIT(S), CIRCUIT NUMBER(S) INDICATED. EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE NOT ALLOWED. EACH 1 POLE BREAKER SHALL BE FURNISHED WITH AN INDIVIDUAL DEDICATED NEUTRAL CONDUCTOR.CONDUIT, STUBBED, CAPPED AND MARKED WITH PULL CORD AS SPECIFIED CONCEALED IN FLOOR OR UNDERGROUND JUNCTION BOX FOR FUTURE TELEPHONE/DATA OUTLET. MOUNT AT 18" A.F.F. UNO. PROVIDE SINGLE-GANG MUD RING WITH BLANK COVER PLATE. PROVIDE 1" CONDUIT TO NEAREST ACCESSIBLE CEILING SPACE. FLOOR MOUNTED TELEPHONE/DATA OUTLET. PROVIDE 1" CONDUIT TO NEAREST ACCESSIBLE CEILING. INSTALL QUANTITY OF DATA (#D) AND TELEPHONE (#T) CABLES INDICATED TO THE NEAREST DATA RACK. PROVIDE (2) DATA CABLES IF A CABLE QUANTITY IS NOT INDICATED. INTERCOM SYSTEM CALL BUTTON. +46" UNO. CEILING MOUNTED SPEAKER WITH BACKBOX WALL MOUNTED SPEAKER, WITH BACKBOX +80" UNO VOLUME CONTROL, +46" UNO TELEVISION OUTLET, +18" AFF UNO. PROVIDE 1-1/4" CONDUIT TO NEAREST ACCESSIBLE CEILING SPACE CEILING MOUNTED TELEVISION OUTLET TTB TELEPHONE TERMINAL BOARD CT-XX CABLE TRAY, 4" DEEP, WIRE BASKET STYLE, 'XX' INDICATES WIDTH PROVIDE ALL FITTINGS AND SUPPORT HARDWARE REQUIRED FLOOR MOUNTED BOX FOR FUTURE TELEPHONE/DATA OUTLET. JUNCTION BOX WITH SINGLE-GANG MUD RING. PROVIDE 1" CONDUIT TO NEAREST ACCESSIBLE CEILING SPACE. PROVIDE BLANK COVER PLATE. #D,#T TELEPHONE/DATA OUTLET. MOUNT AT 18" A.F.F. UNO. PROVIDE 1" CONDUIT TO NEAREST ACCESSIBLE CEILING. INSTALL QUANTITY OF DATA (#D) AND TELEPHONE (#T) CABLES INDICATED TO THE NEAREST DATA RACK. PROVIDE (2) DATA CABLES IF A CABLE QUANTITY IS NOT INDICATED. #D,#T A. THESE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE; THEREFORE, THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DIVISIONS PRIOR TO ROUGH-IN. REFER TO AND COORDINATE WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL WORK THAT IS REQUIRED BY THE ELECTRICAL CONTRACTOR. B. ALL CONDUIT AND JUNCTION BOXES ARE TO BE CONCEALED UNLESS LOCATED WITHIN DEDICATED ELECTRICAL OR MECHANICAL ROOMS. USE OF SURFACE MOUNTED RACEWAYS IN ALL OTHER SPACES MUST BE APPROVED BY THE ARCHITECT FOR EACH LOCATION. WHERE SURFACE RACEWAYS ARE APPROVED, UTILIZE WIREMOLD, OR APPROVED EQUAL, SURFACE MOUNTED RACEWAYS PAINTED TO MATCH SURROUNDING WALLS. C. REFER TO ARCHITECTURAL ELEVATIONS FOR OUTLET HEIGHTS WHERE THE SPECIFIC OUTLET HEIGHT IS NOT INDICATED. REFER TO THE ELECTRICAL LEGEND FOR THE DEFAULT OUTLET HEIGHT WHEN NOT INDICATED ON ELEVATIONS OR ON AT THE DEVICES. D. PROVIDE PULL-LINE IN ALL EMPTY CONDUITS. E. TERMINATE ALL LOW-VOLTAGE CONDUITS WITH INSULATED THROAT BUSHING. F. MECHANICAL EQUIPMENT INDICATED IS SHOWN IN AN APPROXIMATE LOCATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. DEMO: G. THE ELECTRICAL DEMOLITION DRAWING(S) PROVIDED ARE INTENDED TO ASSIST THE ELECTRICAL CONTRACTOR IN ESTABLISHING AREAS REQUIRING DISCONNECTION, REMOVAL, OR RELOCATION OF ELECTRICAL EQUIPMENT, OUTLETS, WIRING, DEVICES, FIXTURES, ETC. AND MAY NOT INDICATE ALL DEVICES OR THE FULL EXTENT OF DEMOLITION AND RECONNECTION WHICH MAY BE REQUIRED. THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY EXAMINE ALL REQUIRED DEMOLITION WORK AND INCLUDE ALL LABOR AND INCIDENTALS THAT WILL BE NECESSARY TO PERFORM DEMOLITION RECONNECTION AND TEMPORARY POWER CONNECTIONS IN THE BID. H. ALL ELECTRICAL DEVICES AND WALLS INDICATED ON THE ELECTRICAL DEMOLITION DRAWING(S) ARE TO REMAIN UNLESS OTHERWISE NOTED. USB DUPLEX CONVENIENCE OUTLET, +18" AFF UNO USB FOURPLEX CONVENIENCE OUTLET, +18" AFF UNO RECESSED ENTERTAINMENT BOX SINGLE FACE EXIT SIGN, CEILING MOUNTED PROVIDE UNSWITCHED CONDUCTOR. WALL MOUNTED SINGLE FACE EXIT SIGN WITH EMERGENCY EGRESS LIGHTING. PROVIDE UNSWITCHED CONDUCTOR. MOUNT AT +8'-0" UNO. CEILING MOUNTED. SINGLE FACE EXIT SIGN WITH EMERGENCY EGRESS LIGHTING. PROVIDE UNSWITCHED CONDUCTOR. CEILING MOUNTED. DOUBLE FACE EXIT SIGN WITH EMERGENCY EGRESS LIGHTING. PROVIDE UNSWITCHED CONDUCTOR. HUMIDISTAT, +46" AFF PROVIDE CONDUIT, J-BOX, CONDUCTORS AS REQUIRED TO CONTROL ASSOCIATED UNITS. 15 15 15 BS,BR H HEAT I IONIZATION ID IN DUCT P PHOTOELECTRIC R RELAY WG PROVIDE PROTECTIVE WIRE GUARD PULL STATION, +44" AFF WITH PRE-ALARM COVER FIRE ALARM HORN, +84" AFF UNO FIRE ALARM STROBE, +84" AFF UNO, STROBE INTENSITY INDICATED. 'C' INDICATES CEILING MOUNTED FIRE ALARM HORN/STROBE +84" AFF, UNO, STROBE INTENSITY INDICATED. 'C' INDICATES CEILING MOUNTED FIRE ALARM BELL, +84" AFF UNO. 'C' INDICATES CEILING MOUNTED FIRE ALARM CHIME, +84" AFF UNO. 'C' INDICATES CEILING MOUNTED FIRE ALARM CHIME/STROBE, +84" AFF UNO, STROBE INTENSITY INDICATED. 'C' INDICATES CEILING MOUNTED END OF LINE RESISTOR FLOW SWITCH, PROVIDE MONITOR MODULE AS REQUIRED TAMPER SWITCH, PROVIDE MONITOR MODULE AS REQUIRED PRESSURE SWITCH, PROVIDE MONITOR MODULE AS REQUIRED FIRE SYSTEM ANNUNCIATOR, FLUSH MOUNTED +54"UNO POST INDICATOR VALVE, PROVIDE MONITOR MODULE AS REQUIRED ELECTROMAGNETIC DOOR HOLDER FIRE/SMOKE DAMPER LED INDICATOR LIGHT, CEILING MOUNTED UNO SMOKE DETECTOR, CEILING MOUNTED UNO BEAM DETECTOR, SENDER & RECEIVER RELAY LED INDICATOR LIGHT WITH TEST SWITCH, CEILING MOUNTED UNO CONTROL MODULE MONITOR MODULE FIRE ALARM CONTROL PANEL NAC EXTENDER PANEL DUCT-MOUNTED SMOKE DETECTOR FSA FIRE ALARM KNOX BOX SPEAKER STROBE, +84" AFF UNO. 'C' INDICATES CEILING MOUNTED ST N GFP # PANEL NAME VOLTAGE PHASE # # # # # TVSS LSIGR P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E MU S G R O V E E N G I N E E R I N G , P A 64 5 W . 2 5 T H S T . ID A H O F A L L S , I D 8 3 4 0 2 20 8 -52 3 -28 6 2 ww w . m u s g r o v e p a . c o m PR O J E C T N U M B E R : 2 3 -19 9 7/ 1 3 / 2 0 2 3 1 2 : 5 8 : 3 6 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 ELECTRICAL COVER SHEET 23-010 LT MB 06/29/2023 E0.00 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 07/13/2023 T 3 T T 2 1D 1B 1A D2 E E1D1DC3C1 1A 1B 1D 2 E1ED2D1DC3C1 OFFICE 2 215 OFFICE 1 216 OFFICE 3 217 GROUP ROOM 218 WAITING AREA 219 RECEPTION 220 12 121 2 1 2 1 2 2 2 2 1D 1B 1A D2 E E1D1DC3C1 1A 1B 1D 2 E1ED2D1DC3C1 OFFICE 2 215 OFFICE 1 216 OFFICE 3 217 GROUP ROOM 218 WAITING AREA 219 RECEPTION 220 2 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E MU S G R O V E E N G I N E E R I N G , P A 64 5 W . 2 5 T H S T . ID A H O F A L L S , I D 8 3 4 0 2 20 8 -52 3 -28 6 2 ww w . m u s g r o v e p a . c o m PR O J E C T N U M B E R : 2 3 -19 9 7/ 1 3 / 2 0 2 3 1 2 : 5 8 : 3 6 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 ELECTRICAL DEMO PLAN 23-010 LT MB 06/29/2023 E1.00 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 1/4" = 1'-0"E1.00 1 ELECTRICAL PLAN DEMO 1/4" = 1'-0"E1.00 2 LIGHTING PLAN DEMO KEYED NOTES: SYMBOL USED FOR CALLOUT# 1. DEMO DATA TO NEAREST J-BOX ABOVE DROP CEILING. MAINTAIN CABLES IN LOOPS TO REUSE IN RENOVATION. 2. DEMO POWER TO NEAREST J-BOX ABOVE DROP CEILING. 07/13/2023 T T 3 D D D D D S DIMMING SWITCH - WALL MOUNT, 120/277V, ON/OFF/DIM, 0-10V DIM SENSOR SWITCH WSXA-PDT-D-XX OR EQUAL XX=VERIFY COLOR WITH ARCHITECT PRIOR TO ORDER SWITCH AND OCCUPANCY SENSOR LEGEND EQUAL PRODUCTS FROM WATTSTOPER, LUTRON, LEGRAND, AND EATON WILL BE ACCEPTED D 2 1D 1B 1A D2 E E1D1DC3C1 1A 1B 1D 2 E1ED2D1DC3C1 OFFICE 2 215 OFFICE 1 216 OFFICE 3 217 GROUP ROOM 218 WAITING AREA 219 RECEPTION 220 2 1 3 1D -20 1D -24 1D -22 4 4 4 5 2 1D 1B 1A D2 E E1D1DC3C1 1A 1B 1D 2 E1ED2D1DC3C1 OFFICE 2 215 OFFICE 1 216 OFFICE 3 217 GROUP ROOM 218 WAITING AREA 219 RECEPTION 220 1 1 1D -26 2 A A A A A A A A A A A A 3 3 3 3 3 P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E MU S G R O V E E N G I N E E R I N G , P A 64 5 W . 2 5 T H S T . ID A H O F A L L S , I D 8 3 4 0 2 20 8 -52 3 -28 6 2 ww w . m u s g r o v e p a . c o m PR O J E C T N U M B E R : 2 3 -19 9 7/ 1 3 / 2 0 2 3 1 2 : 5 8 : 3 7 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 ELECTRICAL INSTALL PLAN 23-010 LT MB 06/29/2023 E2.00 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 1/4" = 1'-0"1 ELECTRICAL PLAN INSTALL 1/4" = 1'-0"2 LIGHTING PLAN INSTALL KEYED NOTES: SYMBOL USED FOR CALLOUT# 1. REROUTE CABLE FROM NETWORK JACK BELOW IN WALL TO CCTV CAMERA. 2. RELOCATE EXISITNG POWER/DATA TO 42" AFF 3. SEE DETAIL 1 ON SHEET E3.00 FOR RECESSED ENTERTAINMENT BOX DETAIL. 4. CONTRACTOR TO FIELD VERIFY CIRCUIT. 5. CONNECT TO EXISTING FAN COIL BRANCH CIRCUIT KEYED NOTES: SYMBOL USED FOR CALLOUT# 1. CONNECT BOTH SWITCHLEGS TOGTHER, PROVIDE AND INSTALL 2-GANG BLANK+DECORA COVER. 2. CONTRACTOR TO FIELD VERIFY CIRCUIT. 3. PROVIDE AND INSTALL 0-10V DIMMING CONDUCTORS FROM SWITCH TO LIGHT FIXTURES IN THE ZONE. 12" = 1'-0"3 CONTROL SCHEDULE 07/13/2023 TV FLAT SCREEN WALL STUD STUB UP 4"ABOVE CEILING ACCESSIBLE CEILING VA R I E S TOP PLATE FINISHED FLOOR FLOOR PLATE INSTALL CONDUIT STRAP AS REQUIRED BY NEC (TYPICAL) 70 " ELECTRICAL CONTRACTOR RESPONSIBLE FOR INSTALLATION OF REB ROUGH-IN TYPICAL DETAIL - ACTUAL INSTALLATION MAY VARY 18 " 5" SQUARE JUNCTION BOX WITH SINGLE GANG MUDRING RANDL TB55057 OR EQUAL SINGLE GANG DEVICE COVER RANDL D-51GO12 OR EQUAL 1 1/4"C PVC WITH PULLSTRING FOR DATA/COMMUNICATIONS TO ELECTRICAL PANEL BOARD 1"C EMT FOR POWER CONDUCTORS AS SHOWN ON POWER DRAWINGS ANTI-SHORT PLASTIC BUSHING ARLINGTON INDUSTRIES EMT100 OR EQUAL 1 1/4"C PVC WITH PULLSTRING FOR DATA/COMMUNICATIONS RECESSED ENTERTAINMENT BOX: WIREMOLD: 1- EHWB4 1- EHWBC4-XX COVER 1 EXTRA- EFB810-3/4-11/4 OR EQUAL XX = COLOR TO BE CONFIRMED BY ARCHITECT DOUBLE DUPLEX DEVICE PLATE AND TWO DUPLEX RECEPTACLES SINGLE GANG DATA DEVICE PLATE EXIT T S 1. PROVIDE FRAMING AS REQUIRED. FINISHED CEILING FINISHED FLOOR DETAIL GENERAL NOTES: +18"A.F.F. +46"A.F.F. +84"A.F.F. +96"A.F.F. EMERGENCY LIGHT FIXTURE (U.N.O.) FIRE ALARM NOTIFICATION DEVICE (U.N.O.) TEMPERATURE SENSOR (U.N.O.) THERMOSTAT (U.N.O.) FIRE ALARM PULL-STATION (U.N.O.) +48" GFI DUPLEX RECEPTACLE (U.N.O.) DUAL SWITCH (U.N.O.) SINGLE SWITCH (U.N.O.) QUAD RECEPTACLE (U.N.O.) HORIZONTAL DUPLEX RECEPTACLE (U.N.O.) DUPLEX RECEPTACLE (U.N.O.) HORIZONTAL DATA OUTLET (U.N.O.) DATA OUTLET (U.N.O.) INTERCOM PANEL (U.N.O.) CENTER LOCAL DISCONNECT AT INTERIOR FAN COIL HEIGHT. (SWITCH TO BE KEYED SWITCH) INTERIOR FAN COIL UNIT EXIT SIGN +12" ABOVE DOOR FRAME (U.N.O) P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP PIVOT NORTH ARCHITECTURE 116 SOUTH 6TH STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E MU S G R O V E E N G I N E E R I N G , P A 64 5 W . 2 5 T H S T . ID A H O F A L L S , I D 8 3 4 0 2 20 8 -52 3 -28 6 2 ww w . m u s g r o v e p a . c o m PR O J E C T N U M B E R : 2 3 -19 9 7/ 1 3 / 2 0 2 3 1 2 : 5 8 : 3 8 P M MM H B e h a v i o r a l H e a l t h T I 37 S 2 N D S T R E E T E A S T , R E X B U R G , I D A H O 8 3 4 4 0 ELECTRICAL DETAILS & SCHEDULES 23-010 LT MB 06/29/2023 E3.00 PE R M I T S E T : 0 7 . 1 3 . 2 0 2 3 1" = 1'-0"1 RECESSED ENTERTAINMENT BOX 1" = 1'-0"2 STANDARD MOUNTING HEIGHT 07/13/2023