HomeMy WebLinkAboutPLANS - 23-00456 - MMH Behavioral Health TI - Remodel#.#GRID/LEVEL HEAD
WALL TYPE TAG
WINDOW TAG
DOOR TAG
ROOM NAME
#####ROOM TAG
WALL SECTION
BUILDING SECTIONKEYNOTE TAG
VIEW TITLE
REFERENCE TAG
SECTION #
SECTION #
VIEW # OR LETTER
SHEET #
A#.##
1 SIM DETAIL OR ENLARGED PLAN
CALLOUTACCESSORY TAG
SHEET #
SHEET #
NORTH ARROW
VIEW #
A#.##
1
INTERIOR ELEVATION
LEVEL NAME / ELEVATION
MARKER
1 View Name
1/8" = 1'-0"A101
0 2' 4' 8'
GRAPHIC SCALE
###M
36"
36"
16"
Extra Shelf
CASEWORK TAG
1
A101
1
A1.01SHEET #
VIEW # OR LETTER
SHEET #
##
X
LEVEL
0' -0"
1
A101
BUILDING
ELEVATION
VIEW # OR LETTER
SHEET #
N
XXXXXXX
XXX
XXXx
#####.A
O
H
E
S
T
TA
PD
NE
L I C RA
ES C
F I D A OH
L
EFOR
A
N
I T
S
CET OIS
G
A
R
Y
A.SOR E N S E N J R .
AR-984526
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP:
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
DRAWING INDEX:
PIVOT NORTH ARCHITECTURE PROJECT #:
VICINITY MAP:
7/
1
3
/
2
0
2
3
1
:
3
1
:
2
3
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
COVER SHEET
23-010
AMM
TB
07/13/2023
G0.00
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
MMH Behavioral Health TI
37 S 2ND STREET EAST, REXBURG, IDAHO 83440
07/13/2023
23-010
[LOGO][STAMP
PHONE:
FAX:
CONTACT:
E-MAIL:
MOBILE:
INTERNET:
OWNER
MADISON MEMORIAL HOSPITAL
450 E MAIN ST, OFFICE 4503
REXBURG, IDAHO 83440
208.432.2494 AMOS KINGTON
N/A amos.kington@mmhnet.org
208.432.2494
madisonmemorial.org
[LOGO] [STAMP
PHONE:
FAX:
CONTACT:
E-MAIL:
MOBILE:
INTERNET:
ARCHITECT
PIVOT NORTH ARCHITECTURE
1101 W. GROVE STREET
BOISE, IDAHO 83702
208.690.3108 GARY SORENSEN
N/A gary@pivotnorthdesign.com
N/A
www.pivotnorthdesign.com
[LOGO] [STAMP
PHONE:
FAX:
CONTACT:
E-MAIL:
MOBILE:
INTERNET:
MECHANICAL ENGINEER
MUSGROVE ENGINEERING, P.A.
234 S WHISPERWOOD WAY
BOISE, DAHO 83709
208.384.0585 DUSTIN MILLER
N/A dustinm@musgrovepa.com
N/A
www.musgrovepa.com
[LOGO] [STAMP
PHONE:
FAX:
CONTACT:
E-MAIL:
MOBILE:
INTERNET:
ELECTRICAL ENGINEER
MUSGROVE ENGINEERING, P.A.
234 S WHISPERWOOD WAY
BOISE, IDAHO 83709
208.532.2862 MATTHEW BRADLEY
N/A mattb@musgrovepa.com
N/A
www.musgrovepa.com
INTERNATIONAL PLUMBING CODE
NATIONAL ELECTRICAL CODE
ZONING ORDINANCE:
INTERNATIONAL MECHANICAL CODE
INTERNATIONAL FIRE CODE
INTERNATIONAL ENERGY CONSERVATION CODE
INTERNATIONAL BUILDING CODE
ACCESSIBILITY CODE
APPLICABLE CODES
OTHER CRITERIA
DEFERRED SUBMITTALS
INTERNATIONAL EXISTING BUILDING CODE 2018
ICC/ANSI A117.1/ IBC CODE
2018 EDITION
2018 EDITION
2018 EDITION
2018 EDITION
2017 IDAHO STATE PLUMBING CODE
2017 EDITION
Zoning OrdinanceREXBURG
FIRE ALARM
GENERAL
G0.00 COVER SHEET
G0.02 ACCESSIBILITY COMPLIANCE
G0.03 CODE COMPLIANCE, EXITING AND OCCUPANCY,
WALL TYPES AND DETAILS
ARCHITECTURAL
A2.01 LEVEL 1 - COMPOSITE FLOOR PLAN
A2.11 LEVEL 1 - DEMO AND AREA FLOOR AND CEILING
PLANS
A7.01 DOOR SCHEDULE & TYPES, FINISHES, INTERIOR
ELEVATIONS
ABBREVIATIONS:
#NUMBER OR POUND
ø DIAMETER
ANGLE
@ AT
&AND
CL CENTERLINE
AB ANCHOR BOLT
ACT ACOUSTICAL CEILING TILE
ADJ ADJUSTABLE
AED AUTOMATED EXTERNAL DEFIBRILLATOR
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
ANOD ANODIZED
APPROX APPROXIMATE
ASSOC ASSOCIATED
BD BOARD
BFC BROOM FINISH CONCRETE
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BO BOTTOM OF
BOT BOTTOM
BRG BEARING
BSMT BASEMENT
BTWN BETWEEN
CAB CABINET
CPT CARPET
C.I.P.CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CMU CONCRETE MASONRY UNITS
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCT
CONT CONTINUOUS
CSK COUNTERSINK
CMT CERAMIC MOSAIC TILE
CQT CERAMIC QUARRY TILE
CWB CERAMIC WALL BASE
DBL DOUBLE
DEPT DEPARTMENT
DT DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
EA EACH
EBT EXPANSION BASE TRIM
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATION
EP EPOXY PAINT
EQ EQUAL
EQUIP EQUIPMENT
ESTR EXPOSED STRUCTURE
(NEW OR EXISTING)
EIFS EXTERIOR INSULATION
& FINISH SYSTEM
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
F.D.C.FIRE DEPARTMENT CONNECTION
FB FIRE BLANKET
FE FIRE EXTINGUISHER
F.E.C.FIRE EXTINGUISHER CABINET
FF FACTORY FINISH
F.H.FIRE HYDRANT
FIN FINISH
FL FLOOR LINE
FLR FLOOR
FND FOUNDATION
FOC FACE OF CHANNEL
FOF FACE OF FINISH
FOS FACE OF STUDS
FT FEET
FTG FOOTING
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GB GYPSUM BOARD
GYP.BD.GYPSUM BOARD
HAS HEAD ANCHOR STUD
HCW HOLLOW CORE WOOD
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HW HARDWOOD
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
INV INVERT
JAN JANITOR
JST JOIST
JT JOINT
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
MAT MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MET METAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
ML MEASURING LINE
MO MASONRY OPENING
MTD MOUNTED
MTG MOUNTING
NA NOT APPLICABLE
NB NO BASE (EXPOSED WALL OR FOUNDATION)
NC NEW CONCRETE
NIC NOT IN CONTRACT
NM NEW MASONRY
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
SYMBOLS:
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OFCI OWNER FURNISHED/CONTRACTOR INSTALLED
OFOI OWNER FURNISHED/OWNER INSTALLED
OPNG OPENING
OTA OPEN TO ABOVE
OTS OPEN TO STRUCTURE
OVF OVERFLOW
PC PAINT COLOR
P.I.V. POST INDICATOR VALVE
PLAST PLASTIC
PLYWD PLYWOOD
PR PAIR
R THERMAL RESISTANCE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDL RAIN DRAIN LEADER
RE:REFERENCE
REFRIG REFRIGERATOR
REINF REINFORCING
REQ REQUIRED
RF EPOXY FLOOR SYSTEM
RM ROOM
RO ROUGH OPENING
RST RUBBER STAIR TREADS
RWB RUBBER WALL BASE
RWC RAIN WATER CONDUCTOR
SC SEALED CONCRETE
SCHED SCHEDULE
SCW SOLID CORE WOOD
SGWB SUSPENDED GYPSUM WALL BOARD
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
TEMP TEMPORARY
TO TOP OF
TOM TOP OF MASONRY
TS TUBE STEEL
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
VAR VARIES
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
W/WITH
WC WATER CLOSET
WD WOOD
WF WALL FABRIC
WH WATER HEATER
WM WALK-OFF MAT
W/O WITH OUT
WP WATERPROOF
WRGB WATER RESISTANT GYPSUM BOARD
WT WEIGHT
WWF WELDED WIRE FABRIC
MECHANICAL
M0.00 MECHANICAL COVER SHEET
M0.01 MECHANICAL SPECIFICATIONS
M1.00 MECHANICAL PLANS
M2.00 MECHANICAL DETAILS
M3.00 MECHANICAL SCHEDULES
ELECTRICAL
E0.00 ELECTRICAL COVER SHEET
E1.00 ELECTRICAL DEMO PLAN
E2.00 ELECTRICAL INSTALL PLAN
E3.00 ELECTRICAL DETAILS & SCHEDULES
PLUMBING
P1.00 PLUMBING PLAN
REMODEL EXISTING OFFICE SPACE INTO BEHAVIORAL HEALTH CLINIC. NO CHANGE TO OCCUR IN OCCUPANCY.
ALL EGRESS WILL REMAIN UNCHANGED. BUILDING IS SPRINKLERED.
SCOPE OF WORK:
N
S
2
N
D
S
T
E
S
3
R
D
S
T
E
W 1ST ST
E MAIN ST
MAPLE DR
MADISON
MEMORIAL
HOSPITAL
PROJECT LOCATION
VERTICAL CHANGES IN
LEVELS
1/4" MAX
BEVELED CHANGES IN
LEVELS
2
11/
4
"
-
1
/
2
"
MA
X
48
"
MIN
15
"
MA
X
48
"
MAX
20"
MA
X
44
"
20" - 24"
MA
X
48
"
MIN
15
"
MA
X
48
"
MAX
10"
MA
X
46
"
24" MAX
UNOBSTRUCTED FORWARD REACH OBSTRUCTED FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED SIDE REACH
34
"
M
A
X
MA
X
34
"
RECEPTACLE OUTLET
UNOBSTRUCTED THERMOSTAT
UNOBSTRUCTED SWITCH
RECEPTACLES AND SWITCH MOUNTING HEIGHTS
UNOBSTRUCTED FIRE ALARM
PULL BOX
15
"
M
I
N
.
36
"
M
I
N
.
48
"
M
A
X
.
48
"
M
A
X
.
MIN
60"
MIN
60
"
MIN
24
"
MIN
36
"
MIN
60"
MIN
12"
MIN
36"
MIN
12"
MIN
48
"
MIN
30"
MIN
30
"
MIN
48"
MIN
36"
MIN
24
"
MIN
48
"
X
MIN
60"
15
"
MIN
30
"X
CIRCULAR T-SHAPED
FORWARD PARALLEL FORWARD APPROACH PARALLEL APPROACH
MANEUVERING CLEARANCE IN AN ALCOVEPOSITION OF CELAR FLOOR OR GROUND SPACESIZE OF WHEELCHAIR TURNING SPACE
MIN9"
MIN
11"
MIN
27
"
MIN9"
KNEE CLEARANCE TOE CLEARANCE
25" MAX 25" MAX
MAX
6"
OPERABLE PARTS SHALL
NOT EXTEND BEYOND TOE
CLEARANCE
MIN
8"
MIN
27
"
FIG. 305.5 FIG. 305.7
RE
F
L
E
C
T
I
V
E
S
U
R
F
A
C
E
40
"
M
A
X
T
O
F
A
C
E
O
F
MIRROR SOAP DISPENSER PAPER TOWEL
DISPENSER
18
"
M
I
N
24
"
MA
X
48
"
30
"
TOILET PAPER
DISPENSER
SANITARY
NAPKIN
DISPOSAL
SANITARY
NAPKIN
DISPENSER
66
"
CUSTODIAN
UTILITY SHELF
18
"
M
I
N
-
2
4
"
MIN
18
"
TO
C
O
N
T
R
O
L
S
48
"
M
A
X
TO
C
O
N
T
R
O
L
S
48
"
M
A
X
ELECTRIC HAND
DRYER
TO
C
O
N
T
R
O
L
S
48
"
M
A
X
(COORDINATE WITH
ELECTRICAL)
TO
C
O
N
T
R
O
L
S
40
"
M
A
X
GRAB BARS
39
"
-
4
1
"
MIN
18
"
33
"
-
3
6
"
FINISH FLOOR
MA
X
48
"
FIRE
EXTINGUISHER
CABINET
MA
X
48
"
RING MOUNTED
FIRE
EXTINGUISHER
48
"
M
A
X
34
"
M
A
X
27
"
M
I
N
DIAPER
CHANGING
STATION
TOILET SEAT
COVER
DISPENSER
15
"
M
I
N
48
"
M
A
X
BE
L
O
W
G
R
A
B
B
A
R
S
1 1
/
2
"
NOTE:WALL MOUNTED OBJECTS SHALL NOT HAVE LEADING EDGES THAT EXTEND MORE THAN 4"
INTO THE CIRCULATION ROUTE AT A HEIGHT BETWEEN 27"-80" AFF. PER A117.1 307.
NOTE: WALL BASE NOT PERMITTED TO
ENCROACH ON MANEUVERING CLEARANCES
CL
E
A
R
60
"
M
I
N
FRONT APPROACH -PULL SIDE
CLEAR
18" MIN CL
E
A
R
48
"
M
I
N
FRONT APPROACH -PUSH SIDE
*IF BOTH CLOSER AND LATCH ARE PROVIDED.
CLEAR
12" MIN
CL
E
A
R
60
"
M
I
N
HINGE APPROACH -PULL SIDE
CLEAR
36" MIN
CL
E
A
R
54
"
M
I
N
HINGE APPROACH -PULL SIDE (OPTIONAL)
CLEAR
42" MIN CL
E
A
R
42
"
M
I
N
HINGE APPROACH -PUSH SIDE
CLEAR
22" MIN CL
E
A
R
48
"
M
I
N
HINGE APPROACH -PUSH SIDE
*IF BOTH CLOSER AND LATCH ARE PROVIDED.
CLEAR
22" MIN
CLEAR
12" MIN
54
"
M
I
N
I
F
C
L
O
S
E
R
I
S
P
R
O
V
I
D
E
D
48
"
M
I
N
C
L
E
A
R
LATCH APPROACH -PULL SIDE
CLEAR
24" MIN
48
"
M
I
N
I
F
C
L
O
S
E
R
I
S
P
R
O
V
I
D
E
D
42
"
M
I
N
C
L
E
A
R
LATCH APPROACH -PUSH SIDE
CLEAR
24" MIN
MANEUVERING CLEARANCES @ MANUAL SWING DOORS (117.1 2009 SECTION 404.2.3.2)
CL
E
A
R
48
"
M
I
N
FRONT APPROACH -PUSH SIDE
*IF NOT EQUIPPED WITH CLOSER AND LATCH.
OPENING WIDTH
O
H
E
S
T
TA
PD
NE
L I C RA
ES C
F I D A OH
L
EFOR
A
N
I T
S
CET OIS
G
A
R
Y
A.SOR E N S E N J R .
AR-984526
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
7/
1
3
/
2
0
2
3
1
:
3
1
:
2
3
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
ACCESSIBILITY
COMPLIANCE
23-010
AMM
TB
07/13/2023
G0.02
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
6" = 1'-0"G0.02
A1 CHANGE IN LEVELS
3/8" = 1'-0"G0.02
A3 REACH RANGES
3/8" = 1'-0"G0.02
A2 MISC. MOUNTING HEIGHTS
3/8" = 1'-0"G0.02
C3 CLEAR FLOOR SPACES
3/8" = 1'-0"G0.02
B2 ACCESSORIES MOUNTING HEIGHTS, TYP.
1. WALL TYPES DESCRIBED ON THIS SHEET DO NOT ACCOUNT FOR
REQUIRED BACKING AND/OR SUPPORT FOR WALL MOUNTED
FIXTURES, EQUIPMENT, CASEWORK AND/OR SYSTEMS FURNITURE.
COORDINATE WITH ENLARGED FLOOR PLANS, INTERIOR
ELEVATIONS AND EQUIPMENT PLANS PRIOR TO THE COVERING OF
STUD FRAMING. REFER TO MANUFACTURER'S RECOMMENDATIONS
AND USE DETAIL A5/G0.03 WHERE APPLICABLE
2. PROVIDE SEISMIC BRACING AT ALL WALL TYPES THAT DO NOT
EXTEND TO DECK
3. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE
SEALED AS PER MANUFACTURERS RECOMMENDATION AND IN
ACCORDANCE W/ ASSOCIATED UL LISTING
4. WALL THICKNESS DESCRIBED ON THIS SHEET ARE SHOWN
NOMINALLY IN PLAN REPRESENTATIONS
5. HORIZONTAL BRACING 2'-0" A.F.F. AT FIRST OCCURRENCE AND
EVERY 4'-0" THEREAFTER AT ALL WALLS W/ GYPSUM WALL BOARD
ON ONLY ONE SIDE.
6. SEE A1/G0.03 FOR PARTITION PRIORITY LEGEND FOR SEQUENCING
OF RATED WALL CONSTRUCTION
7. AT ALL WALLS WITH SOUND ATTENUATION, SEAL TOP OF WALL AT
STRUCTURE AND BOTTOM OF WALL WITH SOUND SEALANT
8. AT ALL WALLS THAT EXTEND TO STRUCTURE PROVIDE DEFLECTION
TRACK. SEE DETAILS C3 AND C5/G0.03 FOR TYPICAL CONDITION.
FOR INSTANCES WHERE BEAM INTERRUPTS CONTINUATION OF
WALL TO DECK ABOVE NOTIFY ARCHITECT.
9. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY IF
CLEARANCES AND ADA REQUIREMENTS ARE NOT ACHIEVED.
GENERAL NOTES -WALL TYPES
+/- 4 3/4"
WALL
FIRE RATING:
FIRE TEST:
WALL HEIGHT:
EXTERIOR INTERIOR
SOUND RATING:W46S
NON-RATED
UL U419 (NON-BEARING)
TO DECK ABOVE
45-49 STC
WALL
FIRE RATING:
FIRE TEST:
WALL HEIGHT:
EXTERIOR INTERIOR
SOUND RATING:W48S
NON-RATED
UL U419 (NON-BEARING)
TO DECK ABOVE
45-49 STC
INTERIOR TYPE "X" GYPSUM WALL BOARD,
5/8"
2X WOOD FRAMING
INTERIOR TYPE "X" GYPSUM WALL BOARD,
5/8"
SOUND INSULATION
INTERIOR TYPE "X" GYPSUM WALL BOARD,
5/8"
2X WOOD FRAMING
SOUND INSULATION
DECKING
INTERIOR TYPE "X" GYPSUM WALL BOARD,
5/8"
METAL FLASHING/TRIM
ACOUSTICAL JOINT SEALANT
DECKING
INTERIOR TYPE "X" GYPSUM WALL BOARD,
5/8"
METAL FLASHING/TRIM
ACOUSTICAL JOINT SEALANT
STUDS. RE: FLOOR PLANS AND
WALL TYPES
2X FIRE TREATED SOLID
BLOCKING
NON-RATED WALL
SMOKE TIGHT WALL
TWO HOUR FIRE AND SMOKE WALL
TWO HOUR FIRE WALL
TWO HOUR SHAFT WALL
ONE HOUR FIRE AND SMOKE WALL
ONE HOUR FIRE WALL
PRIORITY 6
PRIORITY 5
PRIORITY 3
PRIORITY 4
PRIORITY 2
PRIORITY 1 HIGHEST
PARTITION PRIORITY LEGEND
LOWEST PRIORITY
HIGHEST PRIORITY RIVET METAL ANGLE
EDGE TO T-BAR @
24" O.C.
CEILING PANEL SLIP
JOINT (NO RIVET)
HEAVY-DUTY
T-BAR GRID SYSTEM
SCHEDULED WALL
LAY-IN ACOUSTIC
CEILING PANEL
NOTE: PROVIDE PERIMETER SUPPORTING
CLOSURE ANGLE. ONE END OF THE CEILING
GRID SHALL BE ATTACHED TO THE CLOSURE
ANGLE ON TWO ADJACENT SIDES. THE
OPPOSITE ENDS SHALL HAVE A 3/4" CLEARANCE
FROM THE WALL AND SHALL REST UPON AND
BE FREE TO SLIDE ON CLOSURE ANGLE.
7/8"
3/4" MIN
7/8"
C R O S S R U N N E R2" MIN MAIN RUNNER
45 deg. MAX 45 deg. MAX
2" MIN
VERTICAL HANGER
WIRES 4'-0" OC
SPLAY HANGER WIRE AT
12'-0" O.C. EACH PLANE,
EACH RUNNER
1 5/8" STUD
FOR COMPRESSION
1 2 '-0 " T Y P I C A L
1
2
'
-
0
"
T
Y
P
I
C
A
L
4 '-0 " M A X
45 O
G0.03
B3
CEILING
SUSPENSION SYSTEM
FIRST LINE OF
BRACING 4'-0" OR
LESS FROM WALL
BOUNDARY
2
1D
1B
1A
D2 E E1D1DC3C1CB3
1A
1B
1D
2
E1ED2D1DC3C1CB3
195 SF
GROUP ROOM
B
10
114 SF
WAITING AREA
B
3
99 SF
RECEPTION
B
2
107 SF
OFFICE 3
B
3
107 SF
OFFICE 1
B
3 101 SF
OFFICE 2
B
3
MAX EXIT
DISTANCE: 83' -9"
COMMON PATH OF
TRAVEL: 28' -9"
603.1 SCOPE. -LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR
ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR
THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT.
CODE ANALYSIS SUMMARY
CLASSIFICATION OF WORK (PER IEBC CHAPTER 6)
GENERAL BUILDING HEIGHTS AND AREAS (PER IBC CHAPTER 5)
CONSTRUCTION TYPE:
V-B
ACTUAL/EXISTING
42' -APPROX.
3
15,000 -APPROX.
BUILDING HEIGHT IN FEET (TABLE 504.3):
V-B (B) SPRINKLERED
BUILDING HEIGHT IN STORIES (TABLE 504.4):
V-B (B) NON-SPRINKLERED
ALLOWABLE BUILDING AREA (506.2.3):
MIXED OCCUPANCIES: ACCESSORY OCCUPANCIES
ALLOWABLE
60'
3
27,000
PROJECT SUMMARY -EXISTING OCCUPANCY [BUSINESS] TO REMAIN. SPACE IS BEING
RECONFIGURED FOR BEHAVIORAL HEALTH COUNSELING AND WILL ENTAIL TWO INDIVIDUAL
COUNSELING ROOMS, RECEPTION AND WAITING AREA, ONE PROVIDER OFFICE SPACE AND A
GROUP THERAPY ROOM. ALL EXITING ROUTES WILL BE MAINTAINED, AS EXIST CURRENTLY. THE
BUILDING AND EXISTING SPACE CURRENTLY HAVE AN AUTOMATIC SPRINKLER SYSTEM THAT
WILL REMAIN.
JURISDICTION
CITY OF REXBURG, IDAHO
ZONING INFORMATION
COMMERCIAL
ORIGINAL CONSTRUCTION
YEAR PERMITTED 2023
APPLICABLE CODES
2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
2018 INTERNATIONAL BUILDING CODE (IBC)
2013 NFPA 72 FIRE ALARM AND SIGNALING CODE
2018 INTERNATIONAL MECHANICAL CODE (IMC)
2017 NATIONAL ELECTRICAL CODE (NEC)
2017 IDAHO STATE PLUMBING CODE -BASED ON THE 2015 UNIFORM PLUMBING CODE (UPC)
ENERGY CODE
2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
ACCESSIBILITY CODES
2018 INTERNATIONAL BUILDING CODE -USED AS SAFE HARBOR
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
2009 ICC A117.1
INTERIOR FINISHES (PER IBC CHAPTER 8) TABLE 803.13
OCCUPANCY
INTERIOR EXIT
STAIRWAYS AND
RAMPS AND EXIT
PASSAGEWAYS
CORRIDORS AND ENCLOSURES
FOR EXIT ACCESS STAIRWAYS
AND RAMPS
ROOMS AND
ENCLOSED SPACES
B C CGROUP: B
FIRE RESISTIVE RATING REQUIREMENTS FOR BUILDING ELEMENTS (PER IBC CHAPTER 6)
CONSTRUCTION TYPE:
PRIMARY STRUCTURAL FRAME (HOURS):
BEARING WALLS-EXTERIOR (HOURS):
BEARING WALLS-INTERIOR (HOURS):
NONBEARING WALLS AND PARTITIONS-EXTERIOR (HOURS):
X < 5'
5' < X < 10'
10' < X < 30'
X > 30'
NONBEARING WALLS AND PARTITIONS INTERIOR (HOURS):
FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (HOURS):
ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (HOURS):
V-B
0
0
0
1
1
0
0
0
0
0
MEANS OF EGRESS (PER IBC CHAPTER 10)
MAXIMUM EXIT ACCESS TRAVEL DISTANCE (FEET):
(IBC TABLE 1017.2)
MAXIMUM COMMON PATH OF EGRESS TRAVEL (FEET):
(IBC TABLE 1006.2.1)
B BUSINESS 300'
B BUSINESS 100'
GROUP(S):B
OCCUPANCY CLASSIFICATION AND USE (PER IBC CHAPTER 3)
1004.8 CONCENTRATED BUSINESS USE AREAS -CONCENTRATED BUSINESS USE AREA: THE OCCUPANT LOAD
FACTOR FOR CONCENTRATED BUSINESS USE SHALL BE APPLIED TO TELEPHONE CALL CENTERS, TRADING
FLOORS, ELECTRONIC DATA PROCESSING CENTERS AND SIMILAR BUSINESS USE AREAS WITH A HIGHER DENSITY
OF OCCUPANTS THAN WOULD NORMALLY BE EXPECTED IN A TYPICAL BUSINESS OCCUPANCY ENVIRONMENT.
WHERE APPROVED BY THE BUILDING OFFICIAL, THE OCCUPANT LOAD FOR CONCENTRATED BUSINESS USE
AREAS SHALL BE THE ACTUAL OCCUPANT LOAD, BUT NOT LESS THAN ONE OCCUPANT PER 50 SQUARE FEET
(4.65 M2) OF GROSS OCCUPIABLE FLOOR SPACE.
FIRE BARRIER -1-HOUR FIRE-RESISTIVE RATING PER
IBC SECTION 706 WITH 60-MINUTE RATED
OPENING PROTECTIVES PER IBC TABLE 716.5
LEGEND -EXITING AND
OCCUPANCY PLAN
ROOM NAME
X-1
##
OCCUPANCY CLASSIFICATION (PER IBC CHAPTER 3)
ROOM OCCUPANT LOAD (PER IBC TABLE 1004.1.2)
EXITING TRAVEL DISTANCE
EXISTING BUILDING
AREA OF TENENT IMPROVEMENT
O
H
E
S
T
TA
PD
NE
L I C RA
ES C
F I D A OH
L
EFOR
A
N
I T
S
CET OIS
G
A
R
Y
A.SOR E N S E N J R .
AR-984526
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
7/
1
3
/
2
0
2
3
1
:
3
1
:
2
5
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
CODE COMPLIANCE,
EXITING AND
OCCUPANCY, WALL
TYPES AND DETAILS
23-010
AMM
TB
07/13/2023
G0.03
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
1 1/2" = 1'-0"
WALL TYPES - INTERIOR 01
1 1/2" = 1'-0"G0.03
C3 FRAMING DETAIL TO DECK (PARALLEL TO FLUTES)
1 1/2" = 1'-0"G0.03
C5 FRAMING WALL TO DECK (PERPENDICULAR TO FLUTES)
1/2" = 1'-0"G0.03
A5 MOUNTING PLATE ELEVATION, TYP.
3" = 1'-0"G0.03
A1 PARTITION PRIORITY LEGEND
3" = 1'-0"G0.03
A3 TYPICAL LAY-IN CEILING TILE EDGE DETAIL
12" = 1'-0"G0.03
B3 TYPICAL SEISMIC BRACING DETAIL-01
12" = 1'-0"G0.03
B5 TYPICAL SEISMIC BRACING DETAIL-02
1/8" = 1'-0"G0.03
11 LEVEL 1 - AREA EXITING AND OCCUPANCY PLAN
1" = 20'-0"G0.03
D4 LEVEL 1 - OVERALL EXITING AND OCCUPANCY PLAN
NN
2
1D
1B
1A
3
4
D2 E E1D1DC3C1CB3B
A6
A4A2A1A
4A
5
5A
5B
6
PROJECT AREA
A2.11
E4
EXISTING BUILDING
753 SF
1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES.
2. CONTRACTOR TO NOTIFY ARCHITECT IF REQUIRED ACCESSIBILITY
AND EQUIPMENT CLEARANCES WILL NOT BE MAINTAINED.
3. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF
STUDS FOR NEW GWB WALLS / PARTITIONS.
4. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO FACE OF
FINISH FOR EXISTING CONSTRUCTION.
5. UNLESS NOTED OTHERWISE ALL GWB WALLS SHALL HAVE A 4" STUD
FRAME RETURN AT ALL DOOR AND WINDOW JAMBS.
6. UNLESS NOTED OTHERWISE, RE: G0.02b FOR TYPICAL
MANEUVERING CLEARANCE REQUIREMENTS FOR ALL DOORS.
7. RE: G SERIES SHEETS FOR BUILDING OCCUPANCY PLANS AND FIRE
RESISTIVE CONSTRUCTION REQUIREMENTS.
8. FOR GLAZING RECEIVING WINDOW TREATMENTS, COORDINATE
WITH ROOM FINISH SCHEDULE AND PLANS.
9. FOR WALLS NOT DESIGNATED WITH A WALL TYPE, COORDINATE
WITH ARCHITECT.
GENERAL NOTES -FLOOR PLANS
STUD WALL AND GYPSUM WALL BOARD WALL.
RE: WALL TYPES.
WALL TYPE, RE: SHEET G0.03
DOOR SYMBOL, RE: DOOR SCHEDULE, SHEET A7.01
LEGEND
XXXx
XXXXXXX
NOT IN PROJECT SCOPE
O
H
E
S
T
TA
PD
NE
L I C RA
ES C
F I D A OH
L
EFOR
A
N
I T
S
CET OIS
G
A
R
Y
A.SOR E N S E N J R .
AR-984526
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
7/
1
3
/
2
0
2
3
1
:
3
1
:
2
6
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
LEVEL 1 -
COMPOSITE FLOOR
PLAN
23-010
AMM
TB
07/13/2023
A2.01
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
1/8" = 1'-0"A2.01
E1 LEVEL 1-COMPOSITE FLOOR PLAN
N
NOTES - REFERENCE NOTES
T
TT
1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES.
2. CONTRACTOR TO NOTIFY ARCHITECT IF REQUIRED ACCESSIBILITY
AND EQUIPMENT CLEARANCES WILL NOT BE MAINTAINED.
3. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF
STUDS FOR NEW GWB WALLS / PARTITIONS.
4. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO FACE OF
FINISH FOR EXISTING CONSTRUCTION.
5. UNLESS NOTED OTHERWISE ALL GWB WALLS SHALL HAVE A 4" STUD
FRAME RETURN AT ALL DOOR AND WINDOW JAMBS.
6. UNLESS NOTED OTHERWISE, RE: G0.02b FOR TYPICAL
MANEUVERING CLEARANCE REQUIREMENTS FOR ALL DOORS.
7. RE: G SERIES SHEETS FOR BUILDING OCCUPANCY PLANS AND FIRE
RESISTIVE CONSTRUCTION REQUIREMENTS.
8. FOR GLAZING RECEIVING WINDOW TREATMENTS, COORDINATE
WITH ROOM FINISH SCHEDULE AND PLANS.
9. FOR WALLS NOT DESIGNATED WITH A WALL TYPE, COORDINATE
WITH ARCHITECT.
GENERAL NOTES -FLOOR PLANS
STUD WALL AND GYPSUM WALL BOARD WALL.
RE: WALL TYPES.
WALL TYPE, RE: SHEET G0.03
DOOR SYMBOL, RE: DOOR SCHEDULE, SHEET A7.01
LEGEND
XXXx
XXXXXXX
NOT IN PROJECT SCOPE
2
1D
1B
1A
D2 E E1D1DC3C1
8' - 0"
4"
A7.01
E4
A7.01
E5
OFFICE 2
215
OFFICE 1
216
OFFICE 3
217
GROUP ROOM
218
WAITING AREA
219
RECEPTION
220
W4
6
S
W4
6
S
W4
6
S
W46S
W48S
215
218
217
8.04
1.01
1.01
1.01
1.01
1.02
1.02
1.02
1A
1B
1D
2
E1ED2D1DC3C1
9.18
216
2
1D
1B
1A
D2 E E1D1DC3C1
OFFICE 2
215
OFFICE 1
216
OFFICE 3
217
GROUP ROOM
218
WAITING AREA
219 RECEPTION
220
1A
1B
1D
2
E1ED2D1DC3C1
9' - 10" A.F.F.
9' - 10" A.F.F.
9' - 10" A.F.F.
9' - 10" A.F.F.
9' - 10" A.F.F.
2
1D
1B
1A
D2 E E1D1DC3C1
1A
1B
1D
2
E1ED2D1DC3C1
2.11
2
1D
1B
1A
D2 E E1D1DC3C1
2.07
2.07 2.07
2.07
2.08
2.07
2.07
2.04
2.04
2.09
2.04
2.06 2.09
4"
4' - 5 1/2"
2.10
2.10
2.10
2.10
2.10
2.12
2.122.12
1. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS AND
SPECIFICATIONS FOR ADDITIONAL ITEMS TO BE PROVIDED AT THE
CEILING PLANE AND IN THE WORK.
2. CENTER ALL LIGHT FIXTURES AND SPRINKLER HEADS IN THEIR
RESPECTIVE CEILING PANEL.
3. INSTALL ALL SUSPENSION SYSTEMS FOR ACOUSTICAL PANEL
CEILINGS PER PROVISIONS OF ASTM C 635 AND ASTM C 636.
4. ALL SOFFIT DIMENSIONS SHOWN ARE TO FACE OF FINISH.
5. COORDINATE WITH MECHANICAL & ELECTRICAL DRAWINGS AND
SPECIFICATIONS FOR PHYSICAL SIZES OF ALL CEILING GRILLES,
DIFFUSERS, FIXTURES, CANS, AND ALL RELATED ITEMS.
6. PAINT ALL EXPOSED-TO-VIEW STRUCTURAL STEEL DECK, AND
ASSOCIATED STRUCTURAL ITEMS PAINT COLOR P-1, UNLESS
OTHERWISE NOTED.
7. PAINT ALL EXPOSED-TO-VIEW MECHANICAL DUCTWORK AND
ASSOCIATED ITEMS, ELECTRICAL CONDUIT AND ASSOCIATED ITEMS,
PLUMBING AND FIRE PROTECTION LINES AND ALL ASSOCIATED
ITEMS PAINT COLOR P-1, UNLESS OTHERWISE NOTED.
8. SUSPENSION SYSTEMS FOR GYPSUM BOARD CEILINGS SHALL BE
INSTALLED PER ASTM C754.
GENERAL NOTES -CEILINGS
O.T.S.
X' -X"
LEGEND
2' x 2' ACOUSTICAL CEILING METAL
SUSPENSION SYSTEM WITH ACOUSTICAL
PANEL CEILING UNITS, APC-1, U.O.N. RE:
FINISH SCHEDULE.
OPEN TO STRUCTURE
VERTICAL SERVICE DROP/CHASE.
COORDINATE WITH MECHANICAL
DRAWINGS.
LIGHTING FIXTURES, COORDINATE WITH
ELECTRICAL DRAWINGS.
MECHANICAL FIXTURES, COORDINATE
WITH MECHANICAL DRAWINGS.
CEILING HEIGHT ABOVE FINISH FLOOR
EXISTING ACOUSTICAL CEILING SYSTEM TO
REMAIN. PROTECT FROM DAMAGE
DURING CONSTRUCTION. REPLACE
DAMAGED CEILING UNITS.
EXISTING ACOUSTICAL CEILING SYSTEM TO
BE REMOVED. COORDINATE WITH NEW
CONSTRUCTION SCOPE OF WORK.
1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF
STUDS FOR GWB WALLS/PARTITIONS.
2. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO FACE OF
FINISH FOR EXISTING CONSTRUCTION.
3. SCREENED LINES REPRESENT EXISTING WALLS, DOORS, WINDOWS,
ETC TO REMAIN. PROTECT FROM DAMAGE DURING CONSTRUCTION
ACTIVITIES.
4. FOR DIMENSIONAL EXTENTS OF EXISTING WALL DEMOLITION,
CUTTING AND PATCHING, SEE NEW FLOOR PLANS.
5. PROTECT FROM DAMAGE ALL EXISTING TO REMAIN CASEWORK,
EQUIPMENT, FLOOR FINISHES AND CEILING FINISHES DURING
CONSTRUCTION.
6. PROTECT FROM DAMAGE DURING DEMOLITION, MOVING AND
CONSTRUCTION ALL EXISTING CASEWORK, EQUIPMENT, FURNITURE
AND ARTWORK THAT IS TO BE RE-USED.
7. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
DEMOLITION WORK.
8. COORDINATE THE DEMOLITION OF EXISTING CEILING WITH NEW
PLANS, REFLECTED CEILING PLANS AND ROOM FINISH SCHEDULE.
9. WHERE EXISTING CARPET/CARPET TILE ARE TO REMAIN, CUT AND
PATCH CARPET AS REQUIRED TO FACILITATE NEW CONSTRUCTION.
GENERAL NOTES -DEMO
EXISTING WALL SYSTEM TO BE REMOVED AND ALL
ASSOCIATED ITEMS TO ACCOMODATE NEW
CONSTRUCTION. RELOCATE MECHANICAL AND
ELECTRICAL ITEMS AS REQUIRED TO ACCOMODATE
NEW CONSTRUCTION. COORDINATE REMOVAL OF
WALL SYSTEM, PATCH AND REPAIR WITH NEW
CONSTRUCTION SCOPE OF WORK.
EXISTING DOOR SYSTEM TO REMAIN. PROTECT
FROM DAMAGE DURING CONSTRUCTION.
EXISTING WALL SYSTEM TO REMAIN. PROTECT
FROM DAMAGE DURING CONSTRUCTION.
LEGEND
EXISTING DOOR SYSTEM TO REMOVED AND ALL
ASSOCIATED ITEMS TO ACCOMODATE NEW
CONSTRUCTION. COORDINATE REMOVAL OF DOOR
SYSTEM, PATCH AND REPAIR WITH NEW
CONSTRUCTION SCOPE OF WORK.
EXISTING WINDOW TO REMAIN
EXISTING WINDOW AND FRAME TO BE REMOVED
O
H
E
S
T
TA
PD
NE
L I C RA
ES C
F I D A OH
L
EFOR
A
N
I T
S
CET OIS
G
A
R
Y
A.SOR E N S E N J R .
AR-984526
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
7/
1
3
/
2
0
2
3
1
:
3
1
:
2
8
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
LEVEL 1 -DEMO AND
AREA FLOOR AND
CEILING PLANS
23-010
AMM
TB
07/13/2023
A2.11
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
N
NOTES - REFERENCE NOTES
1.01 ALIGN FACE OF NEW WALL PLANE WITH EXISTING WALL PLANE,
THERE SHALL BE NO NOTICEABLE SEAMS OR BREAKS IN FINISHED
APPEARANCE OF THE WALL.
1.02 VERIFY EXISTING WALL CONDITIONS. EXTEND PARTIAL-HEIGHT
WALL TO DECK, INCLUDING SOUND INSULATION.
2.04 REMOVE EXISTING WALL SYSTEM AND ALL ASSOCIATED ITEMS.
RELOCATE MECHANICAL AND ELECTRICAL ITEMS AS REQUIRED
TO ACCOMODATE NEW CONSTRUCTION. COORDINATE REMOVAL
OF WALL SYSTEM, PATCH AND REPAIR WITH NEW
CONSTRUCTION SCOPE OF WORK.
2.06 EXISTING WALL SYSTEM. PRESERVE, PROTECT AND REPAIR
DAMAGED AREAS TO ORIGINAL STATE.
2.07 REMOVE AND SALVAGE TO OWNER CASEWORK, COUNTERS, AND
ALL ASSOCIATED ITEMS.
2.08 EXISTING CASEWORK AND COUNTERS TO REMAIN. PRESERVE,
PROTECT, AND REPAIR DAMAGED AREAS TO ORIGINAL STATE.
2.09 REMOVE EXISTING WALL SYSTEM AND ALL ASSOCIATED ITEMS
TO RECEIVE NEW DOOR. RELOCATE MECHANICAL AND
ELECTRICAL ITEMS AS REQUIRED TO ACCOMODATE NEW
CONSTRUCTION. COORDINATE WITH NEW CONSTRUCTION
SCOPE OF WORK.
2.10 REMOVE EXISTING FLOORING AND ACCESSORIES, INCLUDING
WALL BASE. PREPARE SURFACES TO RECEIVE NEW FINISHES.
2.11 REMOVE AND REINSTALL ALL EXISTING FIXTURES AND CEILING
GRID FOR NEW CONSTRUCTION. TIE INTO EXISTING GRID AND
MATCH EXISTING FINISHES AS REQUIRED TO COMPLETE CEILING
ASSEMBLY AT NEW WALL INSTALLATION AND MECHANICAL
WORK.
2.12 REMOVE SECTIONS OF WALL FINISH AS REQUIRED TO INSTALL
ELECTRICAL AND PLUMBING. PATCH AND REPAIR AREAS TO
ORIGINAL STATE. COORDINATE WITH MEP DRAWINGS AND NEW
CONSTRUCTION SCOPE OF WORK.
8.04 INSTALL PRIVACY FILM TO GLAZING. OFCI.
9.18 PROVIDE AND INSTALL WINDOW TREATMENTS RE: FINISH
SCHEDULE AND LEGEND.
3/16" = 1'-0"A2.11
E4 LEVEL 1 - AREA FLOOR PLAN
3/16" = 1'-0"A2.11
C4 LEVEL 1 - AREA CEILING PLAN
3/16" = 1'-0"A2.11
C1 LEVEL 1 - DEMO AREA CEILING PLAN
3/16" = 1'-0"A2.11
E1 LEVEL 1 - DEMO AREA FLOOR PLAN
ALUM -ALUMINUM
FF -FACTORY FINISH AS SPECIFIED
HM -HOLLOW METAL
HPC -HIGH PERFORMANCE COATING
M -MINUTES
P#-PAINT COLOR "NUMBER" (RE: DIVISION 9 SECTION
"INTERIOR PAINTING".
WD -WOOD
S -SMOKE
AN -ANODIZED
ABBREVIATIONS
F
RE
:
D
O
O
R
S
C
H
E
D
U
L
E
AS
S
C
H
E
D
U
L
E
D
RE: DOOR SCHEDULE
AS SCHEDULED
1. REPAINT ALL DOORS, DOOR FRAMES, WINDOW FRAMES, AND TRIM
TO MATCH EXISTING.
2. PAINT ALL METAL FRAMES & ACCESSORIES P-2.
3. ALL HOLLOW METAL FRAME GLAZING STOPS TO BE PLACED ON
ROOM SIDE OPPOSITE FROM HALLWAY / CORRIDOR.
4. PROVIDE FULLY TEMPERED FIRE-RATED GLAZING IN METAL FRAMES
AND DOORS WHERE 60M ASSEMBLY AT DOORS ARE REQUIRED (RE:
DOOR SCHEDULE). FIRE-RATED GLAZING ASSEMBLY SHALL BE 60M.
5. PROVIDE FULLY TEMPERED GLASS UNITS WHERE REQUIRED BY I.B.C.
SECTION 2406.
6. PROVIDE FLOAT GLASS AT CONDITIONS OTHER THAN DESCRIBED IN
THESE GENERAL NOTES.
7. GLASS AT 60M OPENINGS SHALL BE FULLY TEMPERED FIRE-RATED
GLAZING AND CARRY 60M LABEL. WIRE GLASS DOES NOT CARRY
THIS LABEL.
8. COORDINATE ALL INDICATED FRAME DETAILS WITH ACTUAL WALL
CONFIGURATION. APPLY DETAILS AS APPLICABLE.
GENERAL NOTES
AS
S
C
H
E
D
U
L
E
D
2"
2"AS SCHEDULED2"
S1
A1
A7.01
FLOOR FINISHES
ABBREVIATIONS -FINISHES
CPT CARPET TILE
CT CERAMIC TILE
LN LINOLEUM
LVP LUXURY VINYL PLANK
LVT LUXURY VINYL TILE
MCB METAL COVE BASE
PC POLISHED CONCRETE
QT QUARRY TILE
QVT QUARTZ VINYL TILE
RF RUBBER FLOOR TILE
WALL BASE
CT CERAMIC TILE
QTB QUARRY TILE BASE
RB RESILIENT BASE
TZB TERRAZZO BASE
WDB WOOD BASE
WALL FINISHES
CT CERAMIC TILE
GT GLASS TILE
FRP PLASTIC SHEET PANELING
P PAINT
RP RESIN PANEL
RMA RESILIENT MOLDING ACCESSORY
WC VINYL WALL COVERING
WDP WOOD PANELING
WP WRAPPED FABRIC PANEL
CEILINGS
APC ACOUSTICAL PANEL CEILING
WD WOOD CEILING
GBD GYPSUM BOARD
CASEWORK
PL PLASTIC LAMINATE
SDS SOLID SURFACE
TF TRANSPARENT FINISH
WDP WOOD PANELING
RFA RESILIENT FLOOR ACCESSORY
RSA RESILENT STAIR ACCESSORY
RSV RIGID SHEET VINYL
SC SEALED CONCRETE
SD STATIC DISSIPATIVE FLOOR TILE
SV VINYL SHEET FLOOR COVERING
T TILE
TT TILE TRIM
TZ TERRAZZO
WCV WINDOW COVERING
WM WALK OFF MAT
WINDOW TREATMENT
WT WINDOW TREATMENT
1. RE: ROOM FINISH SCHEDULE SHEET FOR ADDITIONAL
INFORMATION ON FLOOR AND WALL FINISHES.
2. TILE PATTERNS MUST MAINTAIN EXACT CONFIGURATION SHOWN.
3. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
4. RE: REFLECTED CEILING PLANS FOR CEILING AND SOFFIT PAINT
COLOR LOCATIONS.
5. ALL TILE PATTERNS ARE TO BE FULL TILES EXCEPT WHERE PATTERN
IS INTERRUPTED BY PORTIONS OF BUILDING. SEE INTERIOR
ELEVATIONS FOR ADDITIONAL INFORMATION.
6. FOR RUBBER WALL BASE JOB FORM INSIDE AND OUTSIDE
CORNERS.
7. PROVIDE ADA COMPLIANT FLOOR ACCESSORIES FOR FLOORING
TRANSITIONS.
8. NOT ALL FLOOR FINISHES ARE SHOWN ON FLOOR FINISH PLANS.
RE: ROOM FINISH SCHEDULE FOR ALL FLOOR FINISH LOCATIONS.
9. ALL DOOR AND WINDOW TRIM TO BE PAINT COLOR P-# UNLESS
OTHERWISE NOTED ON DOOR SCHEDULE.
GENERAL NOTES -FINISHES
1. RE: ROOM FINISH SCHEDULE AND FINISH FLOOR PLANS FOR
MATERIAL AND FINISH INFORMATION.
2. RE: BUILDING INFORMATION SHEETS FOR CODE AND FIRE
INFORMATION.
3. RE: FLOOR PLANS AND DOOR SCHEDULE FOR DOOR AND FRAME
TYPES.
4. PROVIDE RWB AT ALL TOE SPACES OF ALL CABINETS, SIDES OF
CABINETS AND ALL KNEE SPACES BELOW CABINETS.
5. PROVIDE BLOCKING FOR ALL WALL-MOUNTED ACCESSORIES AND
EQUIPMENT.
GENERAL NOTES -
INTERIOR ELEVATIONS
CASEWORK TAG LEGEND
MODEL
NUMBER INDICATES MODEL NUMBER OF AWS CABINET
M
INDICATES A MODIFIED VERSION OF THE AWS
CABINET MODEL REPRESENTED BY THE
PRECEDING NUMBER.
WIDTH INDICATES WIDTH OF CABINET, DIMENSIONED
FROM OUTSIDE FACE TO OUTSIDE FACE.
DEPTH INDICATES DEPTH OF CABINET, DIMENSIONED
FROM FACE OF WALL TO FACE OF CABINET.
HEIGHT
INDICATES HEIGHT OF CABINET, DIMENSIONED
FROM FACE OF FINISHED FLOOR TO TOP OF
COUNTERTOP FOR BASE CABINETS AND FROM
BOTTOM OF CABINET TO TOP OF CABINET FOR
UPPER CABINETS.
MODIFICATION
A DESCRIPTION OF THE MODIFICATION MADE
INDICATED BY THE (M) FOLLOWING THE MODEL
NUMBER
###M
36"
36"
16"
Extra Shelf
MODEL
NUMBER
WIDTH HEIGHT
DEPTH
DESCRIPTION OF
MODIFICATION
"M" INDICATES CABINET
IS MODIFIED
REF NOTE FOR
DESCRIPTION OF AN
EXPANDED MODIFICATION ##
TO
T
O
P
O
F
C
O
N
T
R
O
L
S
4'
-
0
"
2.05
10.10
8.04
EQ EQ
101M
17"
34"
24"
NO SHELF
151
18"
34"
24"
LOCKABLE
254
18"
34"
24"
LOCKABLE
211
16"
34"
24"
LOCKABLE
401
24"
84"
24"
LOCKABLE
302
34"
28"
14"
LOCKABLE
(2)
6.07
6.116.05
10.04
10.05
10.11
22.03
SOUND ATTENUATION BLANKET INSULATION.
RE: FLOOR PLANS AND WALL TYPES.
GYPSUM WALL BOARD TYPE 'X'
WOOD STUD FRAMING. RE: FLOOR PLANS
AND WALL TYPES.
JOINT SEALANT
GYPSUM WALL BOARD TYPE 'X'
JOINT SEALANT
HOLLOW METAL FRAME. RE: FLOOR PLANS, DOOR
SCHEDULE AND DOOR AND FRAME TYPES.
HOLLOW METAL DOOR. RE: FLOOR PLANS, DOOR
SCHEDULE AND DOOR AND FRAME TYPES.FRAME BEYOND
O
H
E
S
T
TA
PD
NE
L I C RA
ES C
F I D A OH
L
EFOR
A
N
I T
S
CET OIS
G
A
R
Y
A.SOR E N S E N J R .
AR-984526
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
7/
1
3
/
2
0
2
3
1
:
3
1
:
2
9
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
DOOR SCHEDULE &
TYPES, FINISHES,
INTERIOR
ELEVATIONS
23-010
AMM
TB
07/13/2023
A7.01
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
1/2" = 1'-0"
DOOR TYPES
1/2" = 1'-0"
STEEL FRAME TYPES
SCHEDULE - DOOR
DOOR #
DOOR FRAME DOOR
HARDWARE REMARKSTYPEWIDTHHEIGHTMATERIALFINISHTYPEMATERIALFINISH
215 F 3' - 0" 7' - 0" WD S1 WD PASSAGE MATCH EXISTING
216 F 3' - 0" 7' - 0" WD S1 WD PASSAGE MATCH EXISTING
218 F 3' - 0" 7' - 0" WD S1 WD PASSAGE MATCH EXISTING
NOTES - REFERENCE NOTES
2.05 EXISTING GLAZING SYSTEM TO REMAIN. PROTECT FROM
DAMAGE.
6.05 8" DIAMETER OPENING IN TOP OF COUNTER FOR TRASH CAN
ACCESS. PROVIDE PVC EDGEBANDING AT ALL OPENING EDGES.
6.07 PLASTIC LAMINATE CABINETS. RE: FINISH SCHEDULE. TYP.
6.11 1-1/4" PLASTIC LAMINATE WRAPPED PANEL CORE COUNTERTOP
WITH BACKSPLASH. RE: FINISH SCHEDULE.
8.04 INSTALL PRIVACY FILM TO GLAZING. OFCI.
10.04 WALL MOUNTED PAPER TOWEL DISPENSER, OFCI.
10.05 WALL MOUNTED SOAP DISPENSER. OFCI
10.10 WALL MOUNTED TV. PROVIDE BLOCKING. COORDINATE
LOCATION WITH OWNER. OFCI. RE: ELECTRICAL.
10.11 WALL MOUNTED SHARPS AND GLOVES DISPENSER/DISPOSAL.
OFCI.
22.03 HANDWASH SINK. COORDINATE WITH PLUMBING DRAWINGS.
SCHEDULE - FINISH LEGEND
FINISH PRODUCT DESCRIPTION MANUFACTURER PRODUCT NUMBER COLOR COMMENTS
ACT-1 CEILING TILE ARMSTRONG - WHITE MATCH EXISTING
ACT-GRID CEILING GRID - WHITE MATCH EXISTING
CPT-1 CARPET TILE J+J FLOORING OUTFITTER MODULAR 7064 OILCLOTH 2399 OFCI
P-1 PAINT (FIELD) SHERWIN WILLIAMS NATURAL TAN SW7567
P-2 PAINT (TRIM) WHITE MATCH EXISTING
PL-1 PLASTIC LAMINATE CASEWORK MATCH EXISTING
RB-1 RUBBER WALL BASE BLACK COORDINATE WITH OWNER
SDS-1 SOLID SURFACE COUNTERTOP LG HORIZON COORDINATE WITH OWNER
WT-1 ROLLER SHADE COORDINATE WITH OWNER
WT-1 WINDOW PRIVACY FILM IMAGEPERFECT iD7 WindowEtch SILVER FROST OFCI
SCHEDULE - ROOM FINISH
ROOM NO.ROOM TITLE
FLOOR WALLS CASEWORK WINDOW
TREATMENT REMARKSMAT.BASE NORTH EAST SOUTH WEST CABINETRY COUNTER TOP
215 OFFICE 2 CPT-1 RB-1 P-1 P-1 P-1 P-1 PL-1 SDS-1 N/A
216 OFFICE 1 CPT-1 RB-1 P-1 P-1 P-1 P-1 N/A SDS-1 N/A
217 OFFICE 3 CPT-1 RB-1 P-1 P-1 P-1 P-1 N/A SDS-1 N/A
218 GROUP ROOM CPT-1 RB-1 P-1 P-1 P-1 P-1 N/A SDS-1 WT-1
219 WAITING AREA CPT-1 RB-1 P-1 P-1 P-1 P-1 N/A SDS-1 N/A
220 RECEPTION CPT-1 RB-1 P-1 P-1 P-1 P-1 N/A SDS-1 N/A
1/4" = 1'-0"A7.01
E4 GROUP ROOM - SOUTH ELEVATION
1/4" = 1'-0"A7.01
E5 OFFICE 2 - SOUTH ELEVATION
3" = 1'-0"A7.01
A1 TYP HEAD DETAIL (JAMB SIM) (HM FRAME/WOOD FRAMED WALL)
M
AIRFLOW
AIRFLOW
S
T FCO
H WCO
S GCO
CO2
CO
NO
SD
--
#
AW
AV
SD
D-X
CFM
X"Ø RD
R-X
X"Ø OD
R-X
CFM
X"Ø
CD
G-X
CFM
X"Ø
TW
TS MPG
FS G
F
GWS
GWR
CWS
CWR
CS
CR
HWS
HWR
L
S
MECHANICAL ABBREVIATIONS
A/C or AC AIR CONDITIONING KW KILOWATT
AFF ABOVE FINISHED FLOOR KWH KILOWATT HOUR
AHU AIR HANDLING UNIT
ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND
AIR CONDITIONING ENGINEERS LAT LEAVING AIR TEMPERATURE
LAV LAVATORY
BTU BRITISH THERMAL UNITS LEED LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN
BTUH BTUS PER HOUR LWT LEAVING WATER TEMPERATURE
CA COMBUSTION AIR MAX MAXIMUM
CC COOLING COIL MCA MINIMUM CIRCUIT AMPS
CFM AIR FLOW RATE (CUBIC FEET PER MINUTE)MOCP MAXIMUM OVERCURRENT PROTECTION
CHWR CHILLED WATER RETURN MIN MINIMUM
CHWS CHILLED WATER SUPPLY
CLG CEILING NC NOISE CRITERIA
CW COLD WATER NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NTS NOT TO SCALE
DEG or ° DEGREE
DIA or Ø DIAMETER OSA OUTSIDE AIR
DB DRY BULB
PD PRESSURE DROP
EA EXHAUST AIR PH or Ø PHASE
EAT ENTERING AIR TEMPERATURE PRV PRESSURE REDUCING VALVE
EER ENERGY EFFICIENCY RATIO
ESP EXTERNAL STATIC PRESSURE RA RETURN AIR
EWT ENTERING WATER TEMPERATURE RPM REVOLUTIONS PER MINUTE
RTU ROOFTOP UNIT
FCO FLOOR CLEANOUT
FD FIRE DAMPER SA SUPPLY AIR
FLA FULL LOAD AMPS SEER SEASONAL ENERGY EFFICIENCY RATIO
FLR FLOOR SFD COMBINATION SMOKE/FIRE DAMPER
FPM FEET PER MINUTE SP STATIC PRESSURE
FT FEET SYM SYMBOL
GA GAUGE T & P TEMPERATURE AND PRESSURE
GCO GRADE CLEANOUT TEMP TEMPERATURE
GPM WATER FLOW RATE (GALLONS PER MINUTE) TYP TYPICAL
HC HEATING COIL UMC UNIFORM MECHANICAL CODE
HP HORSE POWER UPC UNIFORM PLUMBING CODE
HVAC HEATING, VENTILATING, AIR CONDITIONING URL URINAL
HW HOT WATER
HWR HOT WATER RETURN VTR VENT THROUGH ROOF
HWS HOT WATER SUPPLY V VOLTS
IBC INTERNATIONAL BUILDING CODE W/ WITH
IEEC INTERNATIONAL ENERGY CONSERVATION CODE WB WET-BULB
IFC INTERNATIONAL FIRE CODE WC WATER CLOSET
IFGC INTERNATIONAL FUEL GAS CODE WCO WALL CLEANOUT
IMC INTERNATIONAL MECHANICAL CODE WH WATER HEATER
IPC INTERNATIONAL PLUMBING CODE
NOTE:THIS IS A STANDARD LIST OF COMMONLY USED MECHANICAL ABBREVIATIONS. SOME OF THE ABBREVIATIONS SHOWN ABOVE
MAY NOT BE USED IN THIS DRAWING PACKAGE.
MECHANICAL AND PLUMBING DRAWINGS LEGEND
FLEXIBLE DUCTWORK THREE WAY CONTROL VALVE
DUCTWORK TWO WAY CONTROL VALVE
DUCTWORK BREAK PRESSURE REDUCING VALVE
DUCTWORK OR PIPING RISE GATE VALVE
CONCENTRIC SQUARE TO
ROUND
TRANSITION
REDUCER
MOTORIZED DAMPER GLOBE VALVE
MANUAL VOLUME DAMPER BALL VALVE
SPIN-IN FITTING W/ AIR EXTRACTOR
AND HAND DAMPER BUTTERFLY VALVE
HIGH EFFICIENCY FITTING W/ HAND DAMPER BALANCE VALVE
SWITCH CHECK VALVE
THERMOSTAT FLOOR CLEANOUT
HUMIDISTAT WALL CLEANOUT
TEMPERATURE SENSOR GRADE CLEANOUT
CARBON DIOXIDE SENSOR WATER HAMMER ARRESTOR
CARBON MONOXIDE SENSOR FLOOR DRAIN
NITROUS OXIDE SENSOR FLOOR SINK
DUCT SMOKE DETECTOR GAS PRESSURE REGULATOR W/ GAS COCK
COMBINATION SMOKE/FIRE DAMPER PRESSURE RELIEF VALVE
FIRE DAMPER VENT-THROUGH-ROOF
SMOKE DAMPER VENT
EQUIPMENT CALLOUT SOIL, WASTE, OR SANITARY SEWER
TURNING VANES ACID WASTE LINE
INTAKE OR EXHAUST ACID VENT LINE
DIRECTION OF AIRFLOW STORM DRAIN
SUPPLY DIFFUSER ROOF DRAIN LINE
RETURN GRILLE OVERFLOW DRAIN LINE
EXHAUST GRILLE CONDENSATE DRAIN LINE
FLOOR GRILLE DOMESTIC COLD WATER (CW)
CEILING EXHAUST FAN DOMESTIC HOT WATER (HW)
TEMPERATURE GAUGE DOMESTIC HOT WATER RETURN (HWR)
PRESSURE GAUGE (LIQUID
FILLED W/ ISOLATION VALVE)TEMPERED WATER (TW)
TEMPERATURE SENSOR (DUCT OR PIPING)MEDIUM PRESSURE NATURAL GAS
FLOW SWITCH LOW PRESSURE NATURAL GAS
STAINLESS STEEL BRAIDED
FLEX
CONNECTION
FIRE SPRINKLER LINE
ELASTOMETRIC FLEX CONNECTOR GEOTHERMAL WATER SUPPLY
SUCTION DIFFUSER GEOTHERMAL WATER RETURN
Y TYPE STRAINER (1-1/2" OR LARGER
PROVIDED W/ BLOW DOWN VALVE)CHILLED WATER SUPPLY
FLOW DIRECTION CHILLED WATER RETURN
DEMOLITION / EQUIPMENT TO BE REMOVED CONDENSER WATER SUPPLY
NEW TO EXISTING CONNECTION POINT CONDENSER WATER RETURN
(E)EXISTING HEATING WATER SUPPLY
(F)FUTURE HEATING WATER RETURN
(N)NEW LIQUID REFRIGERANT LINE
REDUCED PRESSURE
BACKFLOW PREVENTER SUCTION REFRIGERANT LINE
DOUBLE CHECK BACKFLOW PREVENTER SLOPE PIPE IN DIRECTION OF ARROW
UNION PIPE ANCHOR
AIR VENT PIPE GUIDE
TRIPLE DUTY VALVE CAP
NOTE:THIS IS A LIST OF COMMONLY USED MECHANICAL AND PLUMBING SYMBOLS. SOME OF THE SYMBOLS SHOWN ABOVE
MAY NOT BE USED IN THIS DRAWING PACKAGE.
MECHANICAL GENERAL NOTES
1. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE
(IMC) LATEST EDITION, AND ALL APPLICABLE LOCAL AND STATE CODES.
2. ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST ADOPTED PLUMBING CODE,
AND ALL LOCAL AND STATE CODES.
3. ALL MECHANICAL AND PLUMBING EQUIPMENT SHALL BE INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS.
4. MECHANICAL CONTRACTORS SHALL RECEIVE PRIOR APPROVAL FROM THE STRUCTURAL ENGINEER BEFORE MAKING CUTS
THROUGH ANY STRUCTURAL MEMBER.
5. MECHANICAL CONTRACTORS SHALL COORDINATE INSTALLATION WITH CONSTRUCTION SUPERVISOR AND WITH ALL OTHER
TRADES TO AVOID CONFLICTS.
6. THE MECHANICAL CONTRACTORS SHALL VERIFY MOTOR VOLTAGES WITH THE ELECTRICAL DRAWINGS PRIOR TO ORDERING
MOTORIZED EQUIPMENT AND CONTROLS.
7. SEE MECHANICAL SCHEDULE SHEET FOR SCHEDULED CAPACITIES OF ALL MECHANICAL EQUIPMENT AND MATERIALS SPECIFIED.
8. DOMESTIC WATER SERVICE IS PROVIDED WITH AN EXISTING BACKFLOW PREVENTER ASSEMBLY.
9. THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR ALL BACKFLOW DEVICES TO INSPECTED BY A CERTIFIED BACKFLOW
TECHNICIAN BEFORE THE USE OF THE BUILDING POTABLE WATER SYSTEM.
10. ALL MECHANICAL EQUIPMENT TO BE PROPOSED MUST BE ON THE APPROVED LIST PRIOR TO SUBMITTALS. ALL APPROVED
MANUFACTURERS MUST BE CAPABLE OF MEETING THE REQUIREMENTS OF THE SPECIFIED EQUIPMENT.
11. RUNOUT AND HOOKUP SIZES TO INDIVIDUAL PLUMBING FIXTURES CAN BE FOUND ON THE PLUMBING FIXTURE SCHEDULE.
12. PROVIDE REMOTE CEILING ACCESS BALANCE DAMPERS WITH CONCEALED CHROME PLATE COVERS FOR BALANCE DAMPERS
LOCATED ABOVE HARD CEILINGS.
13. PAINT VTR'S, FLUES, EXHAUST CAPS, AND OTHER MECHANICAL ITEMS ON THE ROOF TO MATCH THE ROOF COLOR.
14. INSULATED FLEXIBLE DUCTWORK--IN LENGTHS OF 6'-0" OR LESS--MAY BE USED FOR RUNOUTS TO AIR TERMINALS.
15. MAINTAIN MINIMUM 10'-0" DISTANCE BETWEEN ALL FRESH AIR INTAKES AND EXHAUST OR GAS FLUE DISCHARGES.
16. LOCATE ACCESS HATCHCES SO AS TO PROVIDE OPTIMUM SERVICEABILITY TO EQUIPMENT AND/OR VALVING. SEE ARCHITECTURAL
SPECIFICATION FOR TYPE AND COLOR. COORDINATE LOCATION WITH ARCHITECTURAL, STRUCTURAL, AND LIGHTING.
17. WHENEVER THERE IS A DISCREPANCY BETWEEN THE RUNOUT DUCT SIZE SHOWN ON THE PLANS AND THAT SHOWN IN THE
SCHEDULE, ALWAYS USE THE LARGER OF THE TWO DUCT SIZES.
18. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR VERIFICATION OF EXISTING JOB CONDITIONS PRIOR TO BID. NO ADDITIONAL
COST SHALL BE AWARDED TO THE SUCCESSFUL CONTRACTOR (OR THEIR SUBCONTRACTORS) AFTER BIDS HAVE BEEN
SUBMITTED AND CONTRACTS AWARDED FOR FAILURE TO VERIFY EXISTING FIELD CONDITIONS. DISCREPANCIES BETWEEN ACTUAL
FIELD CONDITIONS AND CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR ALTERNATIVE
METHODS OF INSTALLATION PRIOR TO THE BIDDING OF THIS PROJECT.
19. UNLESS OTHERWISE NOTED, ALL EXISTING MECHANICAL EQUIPMENT, PIPING, ETC, TO BE REMOVED SHALL BE DISPOSED OF BY
THE CONTRACTOR UNDER THIS CONTRACT. THE OWNER SHALL RETAIN THE RIGHT TO KEEP ANY REMOVED ITEMS.
20. ALL DOMESTIC HOT AND COLD WATER LINES IN THE AREA OF WORK WHICH ARE NO LONGER IN USE DUE TO THIS PROJECT SHALL
BE REMOVED BACK TO THE MAINS AND CAPPED. NO DEAD LEGS ALLOWED.
21. HOLES IN EXISTING WALLS OR FLOORS SHALL BE PATCHED TO MATCH EXISTING WHERE PIPING, DUCTWORK, ETC, WERE
REMOVED OR ADDED DURING THIS PROJECT.
22. DAMAGE TO THE EXISTING FACILITY DURING THE CONSTRUCTION OF THIS PROJECT SHALL BE REPAIRED OR REPLACED BY THE
CONTRACTOR AT NO COST THE OWNER.
A.COMPLIANCE WITH THE LATEST ADOPTED EDITION OF THE INTERNATIONAL ENERGY CONSERVATION CODE IS REQUIRED FOR THIS
PROJECT. THESE NOTES COVER MANDATORY REQUIREMENTS OF THE CODE. ADDITIONAL REQUIREMENTS ARE NOTED ON THE
DRAWINGS AND IN THE SPECIFICATIONS.
B.MINIMUM REQUIREMENTS FOR SUPPLY AND RETURN DUCTWORK INSULATION:
1. R-6: DUCTS LOCATED IN UNCONDITIONED SPACES (SPACE NEITHER HEATED NOR COOLED SUCH AS ABOVE CEILING SPACES,
WALL SPACES, DUCT CHASES, SOFFITS, ATTICS, CRAWL SPACES, UNHEATED BASEMENTS, AND UNHEATED GARAGES).
2. R-12: DUCTS LOCATED OUTSIDE OF THE BUILDING'S INSULATION ENVELOPE (SUCH AS ABOVE THE ATTIC INSULATION).
TYPICAL INSULATION THICKNESS REQUIRED TO MEET THESE REQUIREMENTS:
1. FIBERGLASS DUCT WRAP: R-6, R-12.
2. FIBERGLASS DUCT LINER: R-6, R-12.
C.CONTRACTOR SHALL VERIFY THE R-VALUES OF THE ACTUAL INSULATION USED WITH THE MANUFACTURER. R-VALUES SHALL BE
INSTALLED VALUES.
D.WHERE DUCTS USED FOR COOLING ARE EXTERNALLY INSULATED, THE INSULATION SHALL BE COVERED WITH A VAPOR RETARDER
HAVING A MAXIMUM PERMEANCE OF 0.05 PERM OR ALUMINUM FOIL HAVING A MINIMUM THICKNESS OF 2 MILS. INSULATION HAVING A
PERMEANCE OF 0.05 PERMS OR LESS SHALL NOT BE REQUIRED TO BE COVERED. ALL JOINTS AND SEAMS SHALL BE SEALED TO
MAINTAIN THE CONTINUITY OF THE VAPOR RETARDER.
E.ALL DUCT JOINTS, SEAMS, AND CONNECTIONS SHALL BE FASTENED AND SEALED WITH WELDS, GASKETS, ADHESIVES,
MASTIC-PLUS-EMBEDDED-FABRIC SYSTEMS, OR TAPES. TAPES AND MASTICS SHALL BE LISTED AND LABELED PER UL181A OR
UL181B. DUCT TAPE IS NOT PERMITTED AS A SEALANT ON ANY METAL DUCTS. DUCT CONNECTIONS TO FLANGES OR EQUIPMENT
SHALL BE SEALED AND MECHANICALLY FASTENED.
F.MINIMUM REQUIREMENTS (THICKNESS) FOR PIPING INSULATION SHALL BE AS FOLLOWS:
FLUID NOMINAL PIPE DIAMETER
1.REFRIGERANT SEE SPECIFICATIONS
THE ABOVE INSULATION IS BASED ON HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU-INCH/HOUR-FT2-°F.
G.DOMESTIC HOT WATER PIPING SYSTEMS SHALL BE INSULATED WITH 1" INSULATION HAVING A CONDUCTIVITY NOT EXCEEDING 0.27
BTU-INCH/HOUR-FT2-°F.
H.AN OPERATING AND MAINTENANCE MANUAL SHALL BE PROVIDED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. THE
O&M MANUAL SHALL CONTAIN THE FOLLOWING INFORMATION AS A MINIMUM:
1. EQUIPMENT CAPACITY (INPUT & OUTPUT).
2. EQUIPMENT OPERATING AND MAINTENANCE INSTRUCTIONS.
3. CONTROL SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND
CONTROL SEQUENCES.
4. CONTROL SYSTEM SETPOINTS SHALL BE SHOWN ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR IN PROGRAMMING
COMMENT ON DDC SYSTEMS.
5. A COMPLETE WRITTEN NARRATIVE ON HOW EACH MECHANICAL SYSTEM IS INTENDED TO OPERATE.
ENERGY CODE COMPLIANCE
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
MU
S
G
R
O
V
E
E
N
G
I
N
E
E
R
I
N
G
,
P
A
64
5
W
.
2
5
T
H
S
T
.
ID
A
H
O
F
A
L
L
S
,
I
D
8
3
4
0
2
20
8
-52
3
-28
6
2
ww
w
.
m
u
s
g
r
o
v
e
p
a
.
c
o
m
PR
O
J
E
C
T
N
U
M
B
E
R
:
2
3
-19
9
7/
1
3
/
2
0
2
3
1
2
:
5
7
:
3
5
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
MECHANICAL COVER
SHEET
23-010
DM
TN
06/29/2023
M0.00
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
07/13/2023
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
MU
S
G
R
O
V
E
E
N
G
I
N
E
E
R
I
N
G
,
P
A
64
5
W
.
2
5
T
H
S
T
.
ID
A
H
O
F
A
L
L
S
,
I
D
8
3
4
0
2
20
8
-52
3
-28
6
2
ww
w
.
m
u
s
g
r
o
v
e
p
a
.
c
o
m
PR
O
J
E
C
T
N
U
M
B
E
R
:
2
3
-19
9
7/
1
3
/
2
0
2
3
1
2
:
5
7
:
5
2
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
MECHANICAL
SPECIFICATIONS
23-010
DM
TN
06/29/2023
M0.01
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
07/13/2023
T
TT
1A
1B
1D
2
E1ED2D1DC3C1
OFFICE 2
215
OFFICE 1
216
OFFICE 3
217GROUP ROOM
218
WAITING AREA
219
RECEPTION
220
FC
151 (FC-151)
6"ø
-
80
D 1
6"Ø
(E)FC
150
1 1
2
4
4
5(210 CFM)
(100 CFM)(150 CFM)
(175 CFM)
8"ø
-
22"X10"
R 9 (TYP. OF 2)
6
7
8
1A
1B
1D
2
E1ED2D1DC3C1
1
1
2
2
3
3
4
4
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
MU
S
G
R
O
V
E
E
N
G
I
N
E
E
R
I
N
G
,
P
A
64
5
W
.
2
5
T
H
S
T
.
ID
A
H
O
F
A
L
L
S
,
I
D
8
3
4
0
2
20
8
-52
3
-28
6
2
ww
w
.
m
u
s
g
r
o
v
e
p
a
.
c
o
m
PR
O
J
E
C
T
N
U
M
B
E
R
:
2
3
-19
9
7/
1
3
/
2
0
2
3
1
2
:
5
7
:
5
3
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
MECHANICAL PLANS
23-010
DM
TN
06/29/2023
M1.00
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
KEYED NOTES:
SYMBOL USED FOR CALLOUT#
1/4" = 1'-0"M1.00
D4 HVAC NEW WORK PLAN
1/4" = 1'-0"M1.00
D1 HVAC DEMOLITION PLAN
1. REMOVE EXISTING CEILING DIFFUSER TEMPORARILY FOR CEILING
REPLACEMENT. CLEAN AND REINSTALL IN NEW CEILING. BALANCE
TO INDICATED AIRFLOW.
2. REMOVE EXISTING CEILING RETURN GRILLE TEMPORARILY FOR
CEILING REPLACEMENT. CLEAN AND REINSTALL IN NEW CEILING
WITH NEW FILTERS.
3. REMOVE EXISTING CEILING DIFFUSER AND RELATED DUCTWORK (AS
INDICATED BY HATCH). REINSTALL EXISTING CEILING DIFFUSER IN
NEW LOCATION AND BALANCE TO INDICATED AIRFLOW.
EXTEND/TRIM/MODIFY DUCTWORK AS NECESSARY TO
ACOMMODATE NEW LOCATION.
4. EXISTING AIR TERMINAL TO REMAIN. REBALANCE TO NEW AIRFLOW
(IF APPLICABLE).
5. CLEAN AND REINSTALL RELOCATED EXISTING CEILING DIFFUSER IN
NEW CEILING. BALANCE TO INDICATED AIRFLOW.
6. 22"X10" INTERNALLY LINED TRANSFER DUCT. REFER TO TRANSFER
DUCT DETAIL FOR ADDITIONAL INFORMATION.
7. REBALANCE EXISTING FRESH AIR DUCT TO 70 CFM.
8. ROUTE NEW REFRIGERANT LINES BACK TO EXISTING BRANCH
SELECTOR BOX (BS-14), THIS AREA. FIELD VERIFY EXISTING
CONDITIONS, EXACT LOCATION, AND EXACT REQUIREMENTS.
07/13/2023
FIG. A
18 GA. BLADE MIN.
1/8" CLEARANCE
ALL AROUND
19" TO 48"
FIG. D
FIG. B
UP TO 18"
1/8" CLEARANCE
ALL AROUND
22 GA. BLADE
FIG. C
ELEVATION, TWO
BLADE ARRANGEMENT
DUCT
VOLUME DAMPER
(SEE NOTE 1)
WING NUT
DAMPER ARM
(SEE NOTE 4)
DAMPER BLADE
(SEE NOTE 3)
ROUND DUCT
ROD (SEE NOTE 2)
18" GAGE MINIMUM
BLADE 6" TO 9" WIDE
1/2" ROD
DUCT1/2" QUADRANT
DUCT HEMMED EDGE3/8" QUADRANT
3/8" PIN
NOTES:
1. FOR TAKE-OFFS LARGER THAN 12" DIAMETER, USE A FACTORY MANUFACTURED DAMPER. LOUVERS &
DAMPERS, INC. MODEL CD-600 WITH A LOCKING HAND QUADRANT OR EQUAL.
2. ROD CONTINUOUS ON 2" W.G. CLASS AND ON ALL DAMPERS OVER 12" DIAMETER.
3. BLADE 22 GAGE MIN., BUT NOT LESS THAN TWO GAGES MORE THAN THE DUCT GAGE.
4. PROVIDE REMOTE CEILING OPERATOR WHERE DAMPER IS INACCESSIBLE.
5. FOR DUCTS OVER 12" HIGH USE MULTIPLE BLADE DAMPERS (SEE FIG. C).
6. ALTERNATE MANUFACTURERS INCLUDE: AMERICAN WARMING, SAFE-AIR/DOWCO, J&J, LOUVERS &
DAMPERS, RUSKIN, NAILOR, ARROW UNITED, POTTORFF, & CESCO.
7. PROVIDE STAND-OFF FOR DAMPER ARMS LOCATED W/EXTERNAL INSULATION.
STAND-OFF
STAND-OFF
STAND-OFF
METAL FASTENERS:
OMARK INSUL-PINS, DURO DYNE FASTENERS OR GRIP NAILS
INSTALLED BY GRIP NAIL AIR HAMMER OR AUTO FASTENER EQUIP.
DUCT LINER
NOT MORE THAN 2"
FROM EDGE OF LINER
SPACING
PER SMACNA
(TYPICAL)
ALL ENDS OF LINER TO BE
COATED W/ ADHESIVE AND
SHALL BE BUTTED FIRMLY
TOGETHER
DUCT LINER (TO BE
ADHERED TO DUCT
W/ 100% ADHESIVE
SEE SPECIFICATIONS)
PROVIDE SHEET METAL NOSING OR
SLEEVE OVER ANY EXPOSED LINER
WHICH FACES THE OPPOSITE
DIRECTIONS AS THE AIRFLOW
SHEET METAL DUCT
TOP AND BOTTOM
SECTION OF LINER SHALL
OVERLAP THE SIDES
SECTION
AIR FLOW
1
X
Y
NOTES:
1. TAKE-OFFS SHOULD NOT BE INSTALLED CLOSER THAN TWO WIDTHS
TO ELBOWS OR INTERSECTIONS.
2. SEE BALANCE DAMPER DETAIL.
3. X NOT LESS THAN Y.
4. FLEXIBLE DUCTWORK SHALL BE FLEXMASTER 8-M, THERMAFLEX M-KE
OR AN APPROVED EQUAL. FLEXIBLE DUCTWORK SHALL BE
INSULATED WITH A MINIMUM R VALUE OF 5.
5. RUN-OUT SHALL BE SAME SIZE AS COLLAR.
6. REFERENCE HVAC PLANS FOR REQUIRED BALANCE DAMPER LOCATIONS.
RECTANGULAR OR
ROUND DUCT
(SEE PLAN FOR SIZE)
LOCKING QUADRANT
HANDLE OR REMOTE
CEILING OPERATOR WHERE
DAMPER IS INACCESSIBLE
HIGH EFFICIENCY DUCT
TAKE-OFF (SEE NOTES 1 & 3)
STAND OFF
SEE SECTION 1
RIGID ROUND
DUCT OR
DIFFUSER
COLLAR
NYLON OR STAINLESS STEEL
CLAMP OVER INSULATION
NYLON OR STAINLESS STEEL
CLAMP OVER FLEX DUCT
INSULATION
(SEE NOTE 4)
LISTED AND LABELED TAPE OR
MASTIC PER UL181A OR UL181B
FLEX DUCT
(SEE NOTE 4)
2 #8 1" LONG PAN HEAD
SHEET METAL SCREW
THRU CEILING TRACK
INTO DIFFUSER (TYP.)
BALANCE DAMPER (SEE NOTE 2)
SUSPEND ELBOW FROM STRUCTURE
RIGID SHEET METAL DUCT
(SEE PLAN FOR SIZE)
PROVIDE PLASTIC ELBOW SUPPORT
(THERMAFLEX FLEX-FLOW OR TITUS
FLEX-RIGHT) ON ALL FLEX DUCT
ELBOWS AT DIFFUSERS, SIZED TO FIT
DUCT. ALTERNATE: CONTRACTOR
MAY USE HARD DUCT ELBOW IN
PLACE OF FLEXIBLE DUCT.
INSULATED FLEX
DUCT. MAX
LENGTH 6'-0"
(SEE NOTE 4)
CEILING
GRILLE
SUSPENDED
CEILING TRACK
45°
1.5" MINIMUM
STEEL BAND
1.5" MINIMUM
STEEL BAND
OPTION 1
WIRE
NOTES:
1. SUPPORT SYSTEM SHALL NOT DAMAGE, CRIMP, OR INHIBIT DUCT FREE AREA IN ANY WAY.
2. FLEXIBLE DUCT MUST NOT EXCEED 6'-0" FROM CONNECTION TO TERMINATION.
3. MAXIMUM LENGTH BETWEEN SUPPORTS MUST NOT EXCEED 3'-0" ON CENTER.
4. ATTACH BANDS OR WIRES TO SUPPORT STRUCTURE ABOVE.
5. FLEXIBLE DUCTWORK SHALL BE FLEXMASTER 1-M OR APPROVED EQUAL.
6. FLEXIBLE DUCTWORK SHALL BE INSULATED WITH A MINIMUM R-VALUE OF 6.0.
7. FLEXIBLE DUCTWORK IS FOR INDOOR USE ONLY. DO NOT INSTALL OR STORE PRODUCT WHERE EXPOSURE TO DIRECT
SUNLIGHT CAN OCCUR. PROLONGED EXPOSURE TO SUNLIGHT MAY CAUSE DETERIORATION OF VAPOR BARRIER.
8. TERMINAL DEVICES SHALL BE SUPPORTED INDEPENDENTLY OF THE FLEXIBLE DUCTWORK.
9. REPAIR TURN OR DAMAGED VAPOR BARRIER/JACKET WITH DUCT TAPE LISTED AND LABELED TO UL 181B. IF INTERNAL
CORE IS PENETRATED, REPLACE FLEXIBLE DUCTWORK.
10. AVOID BENDING DUCT ACROSS SHARP CORNERS OR INCIDENTAL CONTACT WITH METAL FIXTURES, PIPES, OR CONDUITS.
11. FLEXIBLE DUCTWORK SHALL NOT BE INSTALLED WITHIN 4 INCHES OF HOT EQUIPMENT (FURNACES, BOILERS, STEAM
PIPES, ETC.) THAT IS ABOVE 250°F.
12. FLEXIBLE DUCTWORK SHALL NOT BE INSTALLED IN CONCRETE, BURIED BELOW GRADE, OR IN CONTACT WITH THE
GROUND.
13. DO NOT INSTALL FLEXIBLE DUCTWORK IN EXPOSED CEILING AREA.
OPTION 2
X
X
R=1.5X
X
90° TURNING VANES
X
X
R=1.5X
X
X
X
R=1.5X
X
X
Y
Y
Z
X
1.5X
Z
X
Y
X
6"
Y+2
Y
Y=3"-8", Z=3"
Y=17"-24", Z=9"
X
Z
Y
X
Y = 2X; Z = SEE PLANS
Y
Z
X
X
Y
X
X
Y
Z
X
Z = X - Y (4" MIN.)
X
Y=9"-16", Z=6"
Y=25" UP, Z=12"
NOTE:
1. ALL DUCTWORK TRANSITIONS SHALL BE CONSTRUCTED AND INSTALLED TO SMACNA, SPECIFICATIONS, AND THE ABOVE
NOTED STANDARDS. ANY DEVIATIONS SHALL BE COORDINATED WITH THE ENGINEER.
WYE FITTINGOFFSETECCENTRIC
TRANSITION
CONCENTRIC
TRANSITION
90° TEE FITTING CONICAL FITTING 90° TEE W/ OVAL
TO ROUND TAP 45° LATERAL TAP
RADIUS ELBOW 90° GORED ELBOW
5 GORE
MITERED ELBOW W/
TURNING VANES
45° GORED ELBOW
3 GORE
Ө = 15° MAXIMUM
20% MAX AREA REDUCTION
Ө = 30° MAXIMUMX
R=1.0X
X X
X
X
Ө = 45° MAXIMUM
R=6" MIN.
1/4
Ө = 15° MAXIMUM
X
X
X
R=1.0X
X
X
1/2
1/4
R=6" MIN.
X X
Ө
R.A.
90° TURNING VANES
S.A.
X
Y
0.25Y, 4" MIN.
X
Y
R=1.5X
X
Y X
X+Y
Y
Y
X
X
Z
NOTE:
1. ALL DUCTWORK TRANSITIONS SHALL BE CONSTRUCTED AND INSTALLED TO SMACNA, SPECIFICATIONS AND THE ABOVE
NOTED STANDARDS. ANY DEVIATIONS SHALL BE COORDINATED WITH THE ENGINEER.
OBSTRUCTION REDUCTIONRADIUS OFFSETMITERED OFFSET45° ELBOW
SQUARE ELBOW
W/ TURNING VANES 90° ELBOW CONCENTRIC TRANSITION ECCENTRIC TRANSITION
DUCT TAKE-OFF RADIUS WYE
SQUARE TEE
W/ TURNING VANES
SQUARE TEE
W/ DUCT TAKE-OFFS
ӨӨ
Ө
Ө
INTERNALLY LINED SHEET
METAL TRANSFER DUCT WITH
MINIMUM 1" THICK INSULATION.
USE JOHNS MANSFIELD
ACOUSTIC DUCT LINER
TRANSFER GRILLE
(TYPICAL)CEILING
PARTITION WALL
SEE PLANS FOR SIZES
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
MU
S
G
R
O
V
E
E
N
G
I
N
E
E
R
I
N
G
,
P
A
64
5
W
.
2
5
T
H
S
T
.
ID
A
H
O
F
A
L
L
S
,
I
D
8
3
4
0
2
20
8
-52
3
-28
6
2
ww
w
.
m
u
s
g
r
o
v
e
p
a
.
c
o
m
PR
O
J
E
C
T
N
U
M
B
E
R
:
2
3
-19
9
7/
1
3
/
2
0
2
3
1
2
:
5
7
:
5
3
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
MECHANICAL
DETAILS
23-010
DM
TN
06/29/2023
M2.00
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
NTSM2.00
C2 BALANCE DAMPER DETAIL
NTSM2.00
E2 DUCT LINER DETAIL
NTSM2.00
C5 DUCT TAKEOFF DETAIL - HIGH EFFICIENT
NTSM2.00
C4 FLEXIBLE DUCT SUPPORT DETAIL
NTSM2.00
E4 ROUND DUCT FITTING DETAILS
NTSM2.00
E5 RECTANGULAR DUCT FITTING DETAILS
NTSM2.00
D2 TRANSFER DUCT DETAIL
07/13/2023
VRF HVAC SYSTEM SCHEDULE
OUTDOOR UNITS
SYMBOL AREA SERVED
NOMINAL
TONS UNIT TYPE
COOLING REQUIRED AT
80°F EDB, 67°F EWB
HEATING REQUIRED
AT 70°F EAT ELECTRICAL
MINIMUM SEER
OPER.
WEIGHT
(LBS)
MANUFACTURER AND MODEL REMARKS
TOTAL MBH SENSIBLE MBH TOTAL MBH MCA MOCP V/Ø
HR-1(E)1ST FLOOR (EXISTING UNIT) 28
HEAT
RECOVERY EXISTING UNIT TO REMAIN - FOR REFERENCE ONLY DAIKIN MODEL REYQ336PBYD EXISTING
TO REMAIN
INDOOR BRANCH SELECTOR UNITS
SYMBOL AREA SERVED CONNECTED OUTDOOR UNIT RATED COOLING CAPACITY NUMBER OF PORTS
ELECTRICAL
MANUFACTURER AND MODEL REMARKS
MCA MOCP V / Ø
BS-14(E)1ST FLOOR NORTH
(EXISTING UNIT)HR-1(E)EXISTING TO REMAIN - FOR REFERENCE ONLY DAIKIN MODEL BS8Q54TVJ EXISTING
TO REMAIN
INDOOR FAN COIL UNITS
FAN
COIL
UNIT
SYMBOL
HEAT
PUMP
SYMBOL
BRANCH
SELECT
SYMBOL
AREA SERVED NOMINAL
TONS UNIT TYPE
SUPPLY FAN COOLING HEATING ELECTRICAL
OSA SOUND
(dB)
OPER.
WEIGHT
(LBS)
MANUFACTURER AND MODEL REMARKS
CFM H/L MBH MBH MCA MOCP V/Ø
FC-150(E)HR-1(E)BS-14(E) BEHAVIORAL HEALTH CLINIC 1.6
SLIM
DUCTED 636 / 530 18.0 20.0 1.6 15 208/1
SEE
PLANS
EXISTING
TO REMAIN DAIKIN MODEL FXMQ (EXISTING TO REMAIN)EXISTING
TO REMAIN
FC-151(N)HR-1(E)BS-14(E)GROUP ROOM 218 1.5
CEILING
CASSETTE 511 / 353 18.0 20.0 0.6 15 208/1 N/A 43 50 DAIKIN MODEL FXZQ18TAVJU 1 , 2 , 3 , 4 , 5
REMARKS:
1. APPROVED ALTERNATE MANUFACTURERS: NONE.
2. CONTROL UNIT WITH MANUFACTURER'S HARD-WIRED WALL CONTROLLER WITH AUTO CHANGEOVER.
3. PROVIDE WITH CONDENSATE PUMP.
4. ELECTRICAL TO PROVIDE DISCONNECT.
5. PROVIDE ISOLATION VALVES ON REFRIGERANT LINES FROM BRANCH SELECTOR UNIT.
DIFFUSER SCHEDULE
SYMBOL NOMINAL SIZE
NECK / RUNOUT
SIZE CFM RANGE REMARKS
6X6 6"Ø 0 - 90 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8
9X9 8"Ø 90 - 200 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8
12X12 10"Ø 200 - 350 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8
15X15 12"Ø 300 - 500 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8
15X15 14"Ø 400 - 650 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8
18X18 16"Ø 600 - 900 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8
21X21 21X21 900 - 1400 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8
6"Ø
CFM
D-1
8"Ø
CFM
D-2
10"Ø
CFM
D-3
12"Ø
CFM
D-4
14"Ø
CFM
D-5
16"Ø
CFM
D-6
21X21
CFM
D-7
REMARKS:
1. ALTERNATE MANUFACTURERS: ANEMOSTAT, J&J REGISTER, NAILOR, METAL-AIRE, TUTTLE & BAILEY, KRUEGER,
PRICE, AND UNITED ENERTECH.
2. SIZES BASED ON TITUS MODEL TDC SERIES.
3. SIZES BASED ON A MAXIMUM NC LEVEL OF 25.
4. ALL DIFFUSERS LOCATED IN LAY-IN CEILING AREAS SHALL BE BORDER TYPE 3 AND BE MOUNTED IN
MANUFACTURER PROVIDED 24"x24" PANELS. ALL DIFFUSERS LOCATED IN HARD CEILING AREAS SHALL BE
BORDER TYPE 6 (BEVELED) SURFACE MOUNTED. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF VARIOUS
CEILING TYPES.
5. SEE HVAC FLOOR PLANS FOR DIRECTIONAL THROW REQUIREMENTS FOR EACH DIFFUSER.
6. ALL OF THE DIFFUSERS SHOWN IN THIS SCHEDULE MAY NOT BE USED. REFERENCE THE HVAC PLAN FOR
DIFFUSER CALL-OUTS AND THE QUANTITY OF EACH SIZE REQUIRED.
7. WHENEVER THERE IS A DISCREPANCY BETWEEN THE RUNOUT DUCT SIZE SHOWN ON THE PLANS AND THAT
SHOWN IN THE SCHEDULE, ALWAYS USE THE LARGER OF THE TWO DUCT SIZES.
8. COLOR TO BE SELECTED BY ARCHITECT.
RETURN & EXHAUST GRILLE SCHEDULE
SYMBOL NOMINAL SIZE
NECK / RUNOUT
SIZE CFM RANGE REMARKS
8X8 6"Ø 0-80 1 , 2 , 3 , 4 , 5 , 6 , 7
10X10 8"Ø 80-180 1 , 2 , 3 , 4 , 5 , 6 , 7
12X12 10"Ø 180-300 1 , 2 , 3 , 4 , 5 , 6 , 7
22X10 6"Ø 0-80 1 , 2 , 3 , 4 , 5 , 6 , 7
22X10 8"Ø 80-180 1 , 2 , 3 , 4 , 5 , 6 , 7
22X10 10"Ø 180-300 1 , 2 , 3 , 4 , 5 , 6 , 7
22X22 12"Ø 300-500 1 , 2 , 3 , 4 , 5 , 6 , 7
22X22 14"Ø 500-750 1 , 2 , 3 , 4 , 5 , 6 , 7
22X10 22X10 500-1100 1 , 2 , 3 , 4 , 5 , 6 , 7
22X22 22X22 1100-2000 1 , 2 , 3 , 4 , 5 , 6 , 7
REMARKS:
1. ALTNERNATE MANUFACTURERS: ANEMOSTAT, CARNES, PRICE, NAILOR, METAL-AIRE, TUTTLE & BAILEY,
KRUEGER, J&J REGISTER, AND UNITED ENERTECH.
2. SIZES BASED ON TITUS MODEL 50F, ALUMINUM EGGCRATE RETURN GRILLE, 1/2" x 1/2" x 1" SPACING (SINGLE
CORE). PROVIDE SQUARE TO ROUND TRANSITION (WHERE ROUND RUN-OUT INDICATED).
3. SIZES BASED ON A MAXIMUM NC LEVEL OF 25.
4. ALL GRILLES LOCATED IN LAY-IN CEILING AREAS SHALL HAVE BORDER #3, UNLESS OTHERWISE INDICATED.
ALL GRILLES LOCATED IN HARD CEILING AREAS SHALL HAVE BORDER #1, UNLESS OTHERWISE INDICATED.
REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF VARIOUS CEILING TYPES. SHEET METAL DUCTWORK
VISIBLE BEHIND GRILLE SHALL BE PAINTED FLAT BLACK.
5. ALL OF THE GRILLES SHOWN IN THIS SCHEDULE MAY NOT BE USED. REFERENCE THE HVAC PLAN FOR GRILLE
CALL-OUTS AND THE QUANTITY OF EACH SIZE REQUIRED.
6. WHENEVER THERE IS A DISCREPANCY BETWEEN THE RUNOUT DUCT SIZE SHOWN ON THE PLANS AND THAT
SHOWN IN THE SCHEDULE, ALWAYS USE THE LARGER OF THE TWO DUCT SIZES.
7. COLOR TO BE SELECTED BY ARCHITECT.
6"Ø
R-1
8"Ø
R-2
10"Ø
R-3
6"Ø
R-4
8"Ø
R-5
10"Ø
R-6
12"Ø
R-7
14"Ø
R-8
22X10
R-9
22X22
R-10
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
MU
S
G
R
O
V
E
E
N
G
I
N
E
E
R
I
N
G
,
P
A
64
5
W
.
2
5
T
H
S
T
.
ID
A
H
O
F
A
L
L
S
,
I
D
8
3
4
0
2
20
8
-52
3
-28
6
2
ww
w
.
m
u
s
g
r
o
v
e
p
a
.
c
o
m
PR
O
J
E
C
T
N
U
M
B
E
R
:
2
3
-19
9
7/
1
3
/
2
0
2
3
1
2
:
5
7
:
5
3
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
MECHANICAL
SCHEDULES
23-010
DM
TN
06/29/2023
M3.00
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
07/13/2023
S-1
PLUMBING FIXTURE SCHEDULE
SYMBOL FIXTURE DESCRIPTION
CONNECTION SIZE
MANUFACTURER / MODEL NUMBER / DESCRIPTION / ADDITIONAL COMMENTS
WASTE VENT TRAP CW HW
SINK - CLINICAL / EXAM
(9" X 12" X 6")
(ADA COMPLIANT)
1-1/2 1-1/2 1-1/2 1/2 1/2
ELKAY MODEL BLR1560: 6" DEEP, STAINLESS STEEL SINK. PROVIDE AND INSTALL CHICAGO FAUCETS MODEL
895-317GN2AFCXKABCP MANUAL FAUCET WITH 4" FIXED CENTERS, SWING SPOUT, NON-AERATING LAMINAR
FLOW CONTROL IN BASE OF SPOUT, AND 4" WRISTBLADES. PROVIDE WITH ELKAY MODEL LK35 STAINLESS
STEEL STRAINER BASKET AND TAILPIECE, AND WATTS SERIES LFUSG-B LEAD-FREE, THERMOSTATIC MIXING
VALVE, ASSE STANDARD 1070 LISTED, BRONZE BODY, INTEGRAL CHECK VALVES, AND SELECTABLE
TEMPERATURE RANGE FROM 80°F TO 120°F.
NOTES:
1. ALL ADA COMPLIANT FIXTURES MUST COMPLY WITH ICC/ANSI A117.1. SEE ARCHITECTURAL PLANS FOR HANDICAPPED FIXTURE DESIGNATIONS, LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS.
2.ALL EXPOSED HW PIPING, CW PIPING, AND DRAIN LINES BENEATH ALL LAVATORIES AND ALL ADA COMPLIANT SINKS MUST BE INSULATED TO PREVENT INJURY. REFER TO ARCHITECTURAL PLANS. INSULATE WITH
MOLDED CLOSED CELL VINYL INSULATION - TRUEBRO, PLUMBEREX, OR EQUAL.
3. SEE SPECIFICATIONS FOR ALTERNATE APPROVED MANUFACTURERS.
1A
1B
1D
2
E1ED2D1DC3C1
OFFICE 2
215
OFFICE 1
216
OFFICE 3
217
GROUP ROOM
218
WAITING AREA
219
RECEPTION
220
FC
151
(E)FC
150
3 3
1 2
S-1
1 1/2"ø SW
4
NOTES:
A. INTERIOR EXPOSED PIPE, VALVES AND FIXTURE TRIM, INCLUDING TRIM BEHIND CASEWORK DOORS SHALL BE
CHROME PLATED.
B. ALL PIPING PENETRATIONS THROUGH FINISHED WALLS SHALL BE PROVIDED WITH CHROME ESCUTCHEONS.
C. ALL SINK TRAPS SHALL BE PROVIDED WITH A CLEANOUT PLUG IN THE BOTTOM OF THE TRAP.
D. ALL PLUMBING FIXTURES SHALL BE CAULKED AND SEALED TO SURROUNDING SURFACES.
SEE PLUMBING FIXTURE
SCHEDULE FOR BOWL &
FAUCET SPECIFICATIONS
CHROME PLATED
COPPER TUBING
WATER RISERS
OTHER PIPING
MATERIALS, SEE
SPECIFICATIONS
CHROME PLATED PIPING AND
FITTINGS, TYPICAL ALL PIPING
BELOW SINKS AND LAVATORIES,
SEE NOTES BELOW
CLEANOUT PLUG
CHROME ESCUTCHEON
NOTES:
1. INTERIOR EXPOSED PIPE, VALVES AND FIXTURE TRIM, INCLUDING TRIM BEHIND CASEWORK DOORS, SHALL BE CHROME PLATED.
2. ALL PIPING PENETRATIONS THROUGH FINISHED WALLS SHALL BE PROVIDED WITH CHROME ESCUTCHEONS.
3. ALL SINK AND LAVATORY TRAPS SHALL BE PROVIDED WITH A CLEANOUT PLUG IN THE BOTTOM OF THE TRAP.
4. ALL PLUMBING FIXTURES SHALL BE CAULKED AND SEALED TO SURROUNDING SURFACES.
5. PLUMBING CONTRACTOR SHALL VERIFY THE LOCATION OF ALL LAVATORIES AND SINKS THAT NEED TO BE INSTALLED WITH THE BRANCH
TAIL PIECE SECTION WITH 3/4" DRAIN CONNECTION. THE PLUMBING CONTRACTOR WILL BE RESPONSIBLE TO VERIFY THE PLUMBING
ROUGH-IN DIMENSIONS AND SHALL TAKE INTO ACCOUNT THE TAIL PIECE EXTENSION DIMENSIONS.
OTHER PIPING MATERIALS. SEE
SPECIFICATIONS
CHROME PLATED
COPPER TUBING
WATER RISERS
TYPICAL CONDENSATE DRAIN
CONNECTION INTO LAVATORY
AND SINK DRAIN PIPING, SEE
MECHANICAL FLOOR PLANS
FOR FAN COIL CONNECTIONS,
SIZES AND PIPING ROUTES
CLEANOUT PLUG
CHROME ESCUTCHEON
BRANCH TAIL PIECE EXTENSION SECTION WITH 3/4"
CONDENSATE DRAIN CONNECTION (PROVIDED
AND INSTALLED BY PLUMBING CONTRACTOR)
CHROME PLATED PIPE AND FITTINGS,
TYPICAL ALL PIPING BELOW SINKS AND
LAVATORIES, SEE NOTES BELOW
SEE PLUMBING FIXTURE
SCHEDULE FOR BOWL &
FAUCET SPECIFICATIONS
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
MU
S
G
R
O
V
E
E
N
G
I
N
E
E
R
I
N
G
,
P
A
64
5
W
.
2
5
T
H
S
T
.
ID
A
H
O
F
A
L
L
S
,
I
D
8
3
4
0
2
20
8
-52
3
-28
6
2
ww
w
.
m
u
s
g
r
o
v
e
p
a
.
c
o
m
PR
O
J
E
C
T
N
U
M
B
E
R
:
2
3
-19
9
7/
1
3
/
2
0
2
3
1
2
:
5
7
:
5
4
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
PLUMBING PLAN
23-010
DM
TN
06/29/2023
P1.00
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
KEYED NOTES:
SYMBOL USED FOR CALLOUT#
1. TIE NEW SANITARY WASTE LINE INTO EXISTING WASHER BOX DRAIN
PIPE IN WALL ABOVE GRADE, THIS AREA. FIELD VERIFY EXISTING
CONDITIONS AND EXACT REQUIREMENTS. COORDINATE GWB
ACCESS AND PIPE ROUTING WITH ARCHITECTURAL.
2. ROUTE VENT PIPING AS NECESSARY TO CONNECT TO EXISTING
VENT SYSTEM SERVING EXISTING WASHER BOX, THIS AREA. FIELD
VERIFY EXISTING CONDITIONS AND EXACT LOCATION. COORDINATE
GWB ACCESS WITH ARCHITECTURAL.
3. ROUTE DOMESTIC WATER PIPING AS NECESSARY TO CONNECT TO
EXISTING DOMESTIC WATER SYSTEM SERVING EXISTING WASHER
BOX. FIELD VERIFY EXISTING CONDITIONS AND EXACT LOCATION.
COORDINATE GWB ACCESS WITH ARCHITECTURAL.
4. ROUTE CONDENSATE DRAIN TO TAILPIECE OF NEARBY EXISTING
SINK. FIELD VERIFY EXISTING CONDITIONS AND EXACT ROUTING.
REFER TO SINK/LAVATORY TAILPIECE DETAIL W/ CONDENSATE FOR
ADDITIONAL INFORMATION.
1/4" = 1'-0"P1.00
D4 PLUMBING PLAN
NTSP1.00
B2 SINK/LAVATORY TAILPIECE & TRAP DETAIL
NTSP1.00
D2 SINK/LAVATORY TAILPIECE & TRAP DETAIL (W/ CONDENSATE)
07/13/2023
M
S
J
J
HC
F
C
C
M
SS
SOS
2
J
J J J
J J
D
TC
PC
OS
S
K
CR
M
M
S
TV
TV
SP
SP
V
IC
H
T
F
F
F
F
F
F
F
EOL
FS
TS
PS
PIV
DH
R
CM
MM
F
F
F
T
F
#
SD
F
EG
J
100A
3P
- BLACK
- RED
- BLUE
- WHITE
- GREEN
PHASE A
PHASE B
PHASE C
NEUTRAL
GROUND
- BROWN
- ORANGE
- YELLOW
- GRAY
- GREEN
PHASE A
PHASE B
PHASE C
NEUTRAL
GROUND
208Y/120 VOLT SYSTEM 480Y/277 VOLT SYSTEM
ELECTRICAL LEGEND - LIGHTING DEVICES ONE LINE
SECURITY
A AMPERES
AC 6" ABOVE BACKSPLASH
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AF AMP FRAME
AIC AMPS INTERRUPTING CAPACITY
AT AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAUGE
BD BOTTOM OF DECK
BS BOTTOM OF STRUCTURE
C CEILING MOUNTED
C CONDUIT
CB CIRCUIT BREAKER
CF COMPACT FLUORESCENT
CKT CIRCUIT
CO CONDUIT ONLY, PROVIDE PULL-LINE
CT CURRENT TRANSFORMER
CTL CONTROL
DC DIRECT CURRENT
(D) DEMOLITION
DEMO DEMOLITION
DET DETAIL
DTT DOUBLE TWIN TUBE
E EMERGENCY
(E) EXISTING
EC ELECTRICAL CONTRACTOR
EL EMERGENCY LIGHT
F FUSE
(F) FUTURE
FACP FIRE ALARM CONTROL PANEL
G/GND GROUND
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GFI GROUND FAULT INTERRUPTER
HH HAND HOLE
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTO
HPS HIGH PRESSURE SODIUM
HVAC HEATING, VENTILATION, & AIR CONDITIONING
IG ISOLATED GROUND
IPCO IDAHO POWER COMPANY
J-BOX JUNCTION BOX
KA KILOAMP
KVA KILO VOLT-AMP
KW KILOWATT
KWH KILOWATT HOUR
LCP LIGHTING CONTROL PANEL
MB MAIN BREAKER
MBR MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MLO MAIN LUGS ONLY
MMC MODULAR METERING CENTER
MH METAL HALIDE
MSB MAIN SWITCH BOARD
MTG MOUNTING
N NEUTRAL
(N) NEW
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NTS NOT TO SCALE
OH OVERHEAD
OS OCCUPANCY SENSOR
P POLES
PC PHOTO-CONTROL
PVC POLYVINYL CHLORIDE
PWR POWER
RE: REFERENCE
REC RECEPTACLE
(R) RELOCATED
SF SQUARE FEET
TBD TO BE DETERMINED
TDR TIME DELAY RELAY
TK TOE KICK
TSP TWISTED SHIELDED PAIR
TRT TRIPLE TUBE
TTB TELEPHONE TERMINAL BOARD
(TYP.) TYPICAL
UC UNDERCABINET
UG UNDERGROUND
U.N.O. UNLESS NOTED OTHERWISE
V VOLT
VA VOLT-AMPERE
W WATT
WG WIRE GUARD
WP WEATHER PROOF/NEMA 3R
ELECTRICAL
ABBREVIATIONS
PROVIDED/
PROVIDE BY
INSTALLED/
INSTALL
PROVIDE AND INSTALL / PROVIDED AND
INSTALLED BY / PROVIDE AND INSTALL
NOTE: THIS IS A STANDARD LIST OF COMMONLY USED
ELECTRICAL ABBREVIATIONS. SOME OF THE
ABBREVIATIONS SHOWN ABOVE MAY NOT BE
USED IN THIS DRAWING PACKAGE.
CIRCUITING SYMBOLS
ELECTRICAL SPECIFICATIONS
COMMUNICATIONS
ELECTRICAL GENERAL NOTES
FIRE ALARM
X
X
OS
D
REB
(unit-#)
(unit-#)
DUAL LEVEL SWITCHING, INSIDE AND OUTSIDE LAMPS OF FIXTURE
TO BE SWITCHED SEPARATELY.
INDIVIDUAL BREAKER WITH SHUNT TRIP, SIZE AND POLES
INDICATED. NEMA 1 UNO
INDIVIDUAL BREAKER, SIZE AND POLES INDICATED. NEMA 1 UNO
+80"
#P
##A
#P
##A
##A
##A
#P
T
REFERENCE FIXTURE SCHEDULE FOR MOUNTING TYPE, MOUNTING HEIGHT,
AND FIXTURE TYPE.
##A
#P
DOUBLE FACE EXIT SIGN, CEILING MOUNTED, PROVIDE UNSWITCHED
CONDUCTOR.
WALL MOUNTED DOUBLE FACE EXIT SIGN PROVIDE UNSWITCHED
CONDUCTOR. MOUNT AT +8'-0" UNO.
WALL MOUNTED SINGLE FACE EXIT SIGN PROVIDE UNSWITCHED
CONDUCTOR. MOUNT AT +8'-0" UNO.
ARROW INDICATES DIRECTION TO BE SHOWN ON SIGN.
1'X1' LIGHT FIXTURE.
1'X1' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP
CONNECTED TO AN UNSWITCHED CONDUCTOR.
1'X4' LIGHT FIXTURE.
1'X4' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP
CONNECTED TO AN UNSWITCHED CONDUCTOR.
2'X4' LIGHT FIXTURE.
2'X4' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP
CONNECTED TO AN UNSWITCHED CONDUCTOR.
2'X2' LIGHT FIXTURE.
2'X2' LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY BACKUP
CONNECTED TO AN UNSWITCHED CONDUCTOR.
DIRECT/INDIRECT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH.
DIRECT/INDIRECT LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH.
PROVIDE EMERGENCY BATTERY BACKUP CONNECTED TO AN
UNSWITCHED CONDUCTOR
STRIP LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH.
STRIP LIGHT FIXTURE. SEE SCHEDULE FOR LENGTH. PROVIDE
EMERGENCY BATTERY BACKUP CONNECTED TO AN UNSWITCHED
CONDUCTOR
WALL MOUNTED LIGHT FIXTURE.
WALL MOUNTED LIGHT FIXTURE, PROVIDE EMERGENCY BATTERY
BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR.
RECESSED LIGHT FIXTURE
RECESSED LIGHT FIXTURE. PROVIDE EMERGENCY BATTERY BACKUP
CONNECTED TO AN UNSWITCHED CONDUCTOR.
ROUND LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE.
POLE LIGHT 1 HEAD WITH POLE
TIME CLOCK
PHOTO CONTROL CELL LOCATED 12" ABOVE ROOF FACING NORTH.
EMERGENCY EGRESS LIGHTING. CONNECT TO AN UNSWITCHED
CONDUCTOR.
INDICATES FIXTURE TYPE. REFER TO FIXTURE SCHEDULE.
EXTERIOR WALL PACK
EMERGENCY EXTERIOR WALL PACK. PROVIDE EMERGENCY BATTERY
BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR
SWITCH, TYPE AS INDICATED. +46"AFF
OCCUPANCY SENSOR. PROVIDE RELAYS AND POWER PACKS AS
REQUIRED.
SINGLE CONVENIENCE OUTLET, +18" AFF UNO
FLOOR MOUNT SINGLE CONVENIENCE OUTLET
DUPLEX CONVENIENCE OUTLET, +18" AFF UNO
FLOOR MOUNT DUPLEX CONVENIENCE OUTLET
EMERGENCY DUPLEX CONVENIENCE OUTLET, +18" AFF UNO
SWITCHED DUPLEX CONVENIENCE OUTLET, +18" AFF UNO
FLOOR MOUNTED SWITCHED DUPLEX CONVENIENCE OUTLET
FOURPLEX CONVENIENCE OUTLET. +18"AFF UNO
FLOOR MOUNT FOURPLEX CONVENIENCE OUTLET
CONNECTION POINT TO EQUIPMENT SPECIFIED, ELECTRICAL
CONTRACTOR TO SUPPLY RACEWAY AND CONDUCTORS AND MAKE
FINAL CONNECTION TO EQUIPMENT UNDER THIS SECTION. UNO
FLOOR MOUNTED CONNECTION POINT, SEE NOTE ABOVE FOR
REQUIREMENTS
JUNCTION BOX
WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO
WALL MOUNTED PUSH BUTTON, HANDICAPPED MOUNT AT SWITCH
HEIGHT UNO
WALL MOUNTED PUSH BUTTON, MOUNT AT SWITCH HEIGHT UNO
MOTOR STARTER/CONTACTOR, SIZE/POLES NEMA 1 UNO AS INDICATED
COMBINATION STARTER AND DISCONNECT, SIZE/POLES, STARTER SIZE
AS INDICATED, NEMA 1 UNO
MECHANICAL EQUIPMENT CALL OUT
SURFACE MULTI-OUTLET RACEWAY
EQUIPMENT CABINET FLUSH MOUNTED
EQUIPMENT CABINET, SURFACE MOUNTED
PANELBOARD. SEE SCHEDULE FOR TYPE.
TRANSFORMER
POWER POLE - DUAL CHANNEL
THERMOSTAT, +46" AFF PROVIDE CONDUIT, J-BOX, CONDUCTORS AS
REQUIRED TO CONTROL ASSOCIATED UNITS. UNO COORDINATE WITH
DIVISION 15.
NON-FUSED DISCONNECT SIZE/ POLES AS INDICATED, NEMA 1 UNO
FUSED DISCONNECT SWITCH, SIZE/POLES, FUSE SIZES AS INDICATED,
NEMA 1 UNO
DELTA WYE TRANSFORMER UNO
PANEL BOARD, SEE SCHEDULE FOR TYPE AND SIZE
CIRCUIT BREAKER, SIZE AND POLES INDICATED
FUSE, SIZE AND TYPE INDICATED, PROVIDE FUSE FOR EACH POLE
INTERRUPTER SWITCH, SIZE AND POLES INDICATED
FUSED SWITCH, SIZE/POLES AND FUSE SIZE INDICATED
DRAW OUT CIRCUIT BREAKER, SIZE AND POLES INDICATED
GROUND FAULT PROTECTION
TRANSIENT VOLTAGE SURGE SUPPRESSION
NEUTRAL
METER AND BASE
AUTOMATIC TRANSFER SWITCH (ATS)
GENERATOR SET, MAIN BREAKER SIZE INDICATED
OVERHEAD SERVICE DROP
DISCONNECT SWITCH, SIZE AND POLES INDICATED. NEMA 1 UNO
MOTOR
SHUNT TRIP COIL
PAD MOUNT TRANSFORMER
DRY TYPE TRANSFORMER
CCTV CAMERA POWER SUPPLY
CCTV SYSTEM POWER SUPPLY
ADJUSTABLE CAMERA (PAN/TILT/ZOOM)
FIXED CAMERA
CAMERA IN OUTDOOR HOUSING
ADJUSTABLE CAMERA (PAN/TILT/ZOOM) IN OUTDOOR HOUSING
CCTV OUTLET, +18" UNO
CEILING MOUNTED CCTV OUTLET
SECURITY SYSTEM KEYPAD CONTROLLER COORDINATE BOX SIZE AND
MUDRING WITH VENDOR
CEILING MOUNTED MOTION SENSOR
WALL MOUNTED MOTION SENSOR, MOUNTING HEIGHT INDICATED
PANIC BUTTON - MOUNTED UNDER COUNTER
KITCHEN EQUIPMENT CALLOUT
TRACK LIGHT
FLOOR MOUNTED JUNCTION BOX
ADJUSTABLE BREAKER SETTINGS
(PER SPECIFICATIONS):
'L'-LONG TIME
'S'-SHORT TIME
'I'-INSTANTANEOUS
'G'-GROUND FAULT
'R'-ENERGY REDUCING MAINTENANCE SWITCH W/STATUS INDICATOR
EMERGENCY EGRESS LIGHTING WITH OUT FIXTURE HEADS.
CONNECT TO AN UNSWITCHED CONDUCTOR.
CARD READER
2 DOUBLE POLE
3 3-WAY
4 4-WAY
K KEYED
P PILOT LIGHT
D DIMMER
HP HORSEPOWER RATED
TO THERMAL OVERLOAD
LV LOW VOLTAGE
OS OCCUPANCY SENSOR
OR LOW VOLTAGE, MOMENTARY OVERRIDE
VS VACANCY SENSOR
a SUPERSCRIPT INDICATES LIGHTS
TO BE SWITCHED TOGETHER
XXX
GROUNDROUND EMERGENCY LIGHT FIXTURE. PROVIDE EMERGENCY BATTERY
BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR.
WALL MOUNTED EMERGENCY LIGHT FIXTURE. PROVIDE EMERGENCY
BATTERY BACKUP CONNECTED TO AN UNSWITCHED CONDUCTOR.
DUAL LEVEL SWITCHING WITH OCCUPANCY SENSOR, INSIDE AND
OUTSIDE LAMPS OF FIXTURE TO BE SWITCHED SEPARATELY.
EXISTING
CONDUIT DOWN CONDUIT UP
6
NEUTRAL CONDUCTORS
GROUNDING CONDUCTOR
SIZE
QUANTITY
1"-4#10,1#10G
PANEL HOMERUN. (3/4"-2#12,1#12G CONDUCTORS UNO)
RACEWAY
A-2,4,6
PANEL NAME
CIRCUIT #
EM
NOTE:
CURRENT
CARRYING
CONDUCTORS
LED DRIVER
T
A. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE
LOCALLY ADOPTED ELECTRICAL CODE, ALL LOCAL CODES, AND TO THE FULL
ACCEPTANCE OF THE AUTHORITY HAVING JURISDICTION.
B. OBTAIN ALL PERMITS, COORDINATE, FURNISH, INSTALL, CONNECT AND TEST
ALL ELECTRICAL EQUIPMENT REQUIRED FOR ALL THE SYSTEMS INSTALLED
UNDER THIS CONTRACT TO INSURE COMPLETE AND FULLY OPERATIONAL
SYSTEMS.
C. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF AS-BUILT DRAWINGS.
AS-BUILT SET OF DRAWINGS SHALL BE UPDATED DAILY AND SHALL
DOCUMENT THE ACTUAL INSTALLED CONDITION OF THE ENTIRE ELECTRICAL
INSTALLATION. AS-BUILT SET OF DRAWINGS SHALL BE AVAILABLE AT ALL
TIMES ON THE SITE FOR INSPECTION BY CODE OFFICIALS, OWNER,
ARCHITECT, AND ENGINEER.
D. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION.
E. DESIGN IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL
FIELD VERIFY EXISTING CONDITIONS TO DETERMINE STATUS OF ACTUAL
CONDITIONS AS THEY RELATE TO THE SCOPE OF WORK AS SHOWN ON THESE
PLANS.
F. COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER TRADES.
G. COORDINATE EXACT LOCATION AND MOUNTING HEIGHTS OF ALL ELECTRICAL
EQUIPMENT AND DEVICES WITH THE ARCHITECTURAL ELEVATIONS AND
DETAILS PRIOR TO ROUGH-IN.
H. DEMOLITION WORK IS A PART OF THIS PROJECT. SEE DRAWINGS FOR
EXISTING ELECTRICAL DEVICES TO BE REMOVED. REMOVE ASSOCIATED
BOXES, RACEWAYS AND CONDUCTORS BACK TO SOURCE, AND MAKE SAFE.
I. ALL MATERIALS AND EQUIPMENT FURNISHED TO THE PROJECT SHALL BE NEW
AND SHALL BEAR THE LISTING LABEL OF A NATIONALLY RECOGNIZED TESTING
LAB AS DEFINED BY OSHA.
J. ALL ELECTRICAL DEVICES AND TERMINALS SHALL BE RATED 75°C MINIMUM.
K. ALL CONDUCTORS SHALL BE STRANDED COPPER, 600 VOLT RATED.
INSULATION TYPE SHALL BE THHN/THWN, FULLY COLOR CODED WITH GAUGE,
TYPE AND MANUFACTURER MARKED EVERY 24" ALONG. CONDUCTOR COLOR
CODE SHALL BE AS FOLLOWS:
L. MINIMUM SIZE WIRE FOR POWER AND LIGHTING CIRCUITS SHALL BE #12 AWG.
ALL POWER AND LIGHTING CONDUCTORS SHALL BE ROUTED IN 3/4" CONDUIT
MINIMUM.
M. EMT OR MC TYPE CABLE IS ALLOWED WHEN CONCEALED IN INTERIOR
SPACES. MC TYPE CABLE IS NOT ALLOWED FOR HOMERUNS.
N. MAKE ALL CONNECTIONS TO EQUIPMENT PER MANUFACTURER'S
REQUIREMENTS.
O. ALL EQUIPMENT, SWITCHING DEVICES AND PANELS SHALL BE MOUNTED SO
AS TO BE ACCESSIBLE AND SHALL BE MOUNTED PLUMB AND SQUARE WITH
WALLS.
P. DEVICES AND RACEWAYS PENETRATING FIRE RATED WALLS AND FLOORS
SHALL BE SEALED WITH FIRE RESISTIVE MATERIAL, COMPATIBLE WITH
CONSTRUCTION PENETRATED, TO MAINTAIN RATING OF THE WALL. SEALANT
SYSTEM SHALL BE A U.L. APPROVED SYSTEM AND INSTALLED PER
MANUFACTURER'S INSTRUCTIONS.
Q. FURNISH AND INSTALL PULL CORD IN ALL EMPTY CONDUITS.
R. ALL JUNCTION BOX COVERS WITH POWER WIRING SHALL HAVE THE PANEL
AND CIRCUIT LABELED ON THE OUTSIDE SURFACE. ALL LABELS FOR EXPOSED
JUNCTION BOXES IN "FINISHED AREAS" SHALL BE LABELED UTILIZING SELF
ADHESIVE LABELS PRODUCED BY A MECHANICAL LABELING MACHINE. LABELS
FOR JUNCTION BOX COVERS IN CONCEALED LOCATIONS SHALL CONSIST OF
THE INFORMATION BEING NEATLY HANDWRITTEN ON THE OUTSIDE SURFACE
OF THE COVER WITH A PERMANENT STYLE MARKER.
S. CLEARLY LABEL ALL ACCESSIBLE CONDUIT STUBS WITH SYSTEM NAME AND
LOCATION (ROOM NUMBER) WHERE THE OTHER END OF THE CONDUIT
TERMINATES. USE INDELIBLE INK. THE LABELS SHALL BE LOCATED ON THE
CONDUIT IN A POSITION THAT CAN BE EASILY READ.
T. ALL 1 POLE BREAKER CIRCUITS SHALL HAVE AN INDEPENDENT NEUTRAL
CONDUCTOR. NO EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE
ALLOWED.
U. ALL CONDUCTORS IN ELECTRICAL PANELS, CABINETS AND EQUIPMENT SHALL
BE NEATLY TRAINED AND LACED.
V. THE CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES
FOR ALL PANELS. DIRECTORIES SHALL BE TYPED.
W. PROVIDE ELECTRICAL SUBMITTALS FOR EQUIPMENT SHOWN AS REQUIRED BY
DIVISION 1 SPECIFICATIONS.
X. ELECTRICAL CONTRACTOR SHALL OBTAIN THE AVAILABLE FAULT CURRENT
VALUE FROM THE LOCAL UTILITY OR THE ONE-LINE DIAGRAM AND LABEL THE
MAIN BREAKER WITH THAT VALUE.
Y. SWITCH AND RECEPTACLE LABELING: IDENTIFY PANELBOARD AND CIRCUIT
NUMBER FROM WHICH DEVICES ARE SERVED. USE MACHINE PRINTED LABEL
AND 1/8" TEXT. INSTALL ON THE OUTSIDE OF THE FACEPLATE FOR
RECEPTACLES AND INSIDE THE FACEPLATE FOR SWITCHES.
OCCUPANCY SENSOR WITH MANUAL DIMMING, SET FOR 50%
AUTOMATIC ON, AUTOMATIC OFF, WITH MANUAL DIMMING.
DESIGNATES CIRCUIT ON
EMERGENCY SOURCE
UNMARKED CIRCUIT IS CONCEALED
IN CEILING OR WALL. MAINTAIN
CONDUIT AND CONDUCTOR SIZE
THROUGHOUT ENTIRE CIRCUIT.
BEGINNING OF INDIVIDUAL
CIRCUIT(S), CIRCUIT
NUMBER(S) INDICATED.
EDISON STYLE SHARED NEUTRAL CONDUCTORS ARE NOT
ALLOWED. EACH 1 POLE BREAKER SHALL BE FURNISHED WITH AN
INDIVIDUAL DEDICATED NEUTRAL CONDUCTOR.CONDUIT, STUBBED, CAPPED AND
MARKED WITH PULL CORD AS SPECIFIED
CONCEALED IN
FLOOR OR
UNDERGROUND
JUNCTION BOX FOR FUTURE TELEPHONE/DATA OUTLET. MOUNT AT 18"
A.F.F. UNO. PROVIDE SINGLE-GANG MUD RING WITH BLANK COVER
PLATE. PROVIDE 1" CONDUIT TO NEAREST ACCESSIBLE CEILING
SPACE.
FLOOR MOUNTED TELEPHONE/DATA OUTLET. PROVIDE 1" CONDUIT TO
NEAREST ACCESSIBLE CEILING. INSTALL QUANTITY OF DATA (#D) AND
TELEPHONE (#T) CABLES INDICATED TO THE NEAREST DATA RACK.
PROVIDE (2) DATA CABLES IF A CABLE QUANTITY IS NOT INDICATED.
INTERCOM SYSTEM CALL BUTTON. +46" UNO.
CEILING MOUNTED SPEAKER WITH BACKBOX
WALL MOUNTED SPEAKER, WITH BACKBOX +80" UNO
VOLUME CONTROL, +46" UNO
TELEVISION OUTLET, +18" AFF UNO. PROVIDE 1-1/4" CONDUIT TO
NEAREST ACCESSIBLE CEILING SPACE
CEILING MOUNTED TELEVISION OUTLET
TTB TELEPHONE TERMINAL BOARD
CT-XX CABLE TRAY, 4" DEEP, WIRE BASKET STYLE, 'XX' INDICATES WIDTH
PROVIDE ALL FITTINGS AND SUPPORT HARDWARE REQUIRED
FLOOR MOUNTED BOX FOR FUTURE TELEPHONE/DATA OUTLET.
JUNCTION BOX WITH SINGLE-GANG MUD RING. PROVIDE 1" CONDUIT
TO NEAREST ACCESSIBLE CEILING SPACE. PROVIDE BLANK COVER
PLATE.
#D,#T TELEPHONE/DATA OUTLET. MOUNT AT 18" A.F.F. UNO. PROVIDE 1"
CONDUIT TO NEAREST ACCESSIBLE CEILING. INSTALL QUANTITY OF
DATA (#D) AND TELEPHONE (#T) CABLES INDICATED TO THE NEAREST
DATA RACK. PROVIDE (2) DATA CABLES IF A CABLE QUANTITY IS NOT
INDICATED.
#D,#T
A. THESE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE; THEREFORE,
THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL
EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL, MECHANICAL,
AND PLUMBING DIVISIONS PRIOR TO ROUGH-IN. REFER TO AND COORDINATE
WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS FOR
ADDITIONAL WORK THAT IS REQUIRED BY THE ELECTRICAL CONTRACTOR.
B. ALL CONDUIT AND JUNCTION BOXES ARE TO BE CONCEALED UNLESS
LOCATED WITHIN DEDICATED ELECTRICAL OR MECHANICAL ROOMS. USE OF
SURFACE MOUNTED RACEWAYS IN ALL OTHER SPACES MUST BE APPROVED
BY THE ARCHITECT FOR EACH LOCATION. WHERE SURFACE RACEWAYS ARE
APPROVED, UTILIZE WIREMOLD, OR APPROVED EQUAL, SURFACE MOUNTED
RACEWAYS PAINTED TO MATCH SURROUNDING WALLS.
C. REFER TO ARCHITECTURAL ELEVATIONS FOR OUTLET HEIGHTS WHERE THE
SPECIFIC OUTLET HEIGHT IS NOT INDICATED. REFER TO THE ELECTRICAL
LEGEND FOR THE DEFAULT OUTLET HEIGHT WHEN NOT INDICATED ON
ELEVATIONS OR ON AT THE DEVICES.
D. PROVIDE PULL-LINE IN ALL EMPTY CONDUITS.
E. TERMINATE ALL LOW-VOLTAGE CONDUITS WITH INSULATED THROAT BUSHING.
F. MECHANICAL EQUIPMENT INDICATED IS SHOWN IN AN APPROXIMATE
LOCATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR
PRIOR TO ROUGH-IN.
DEMO:
G. THE ELECTRICAL DEMOLITION DRAWING(S) PROVIDED ARE INTENDED TO
ASSIST THE ELECTRICAL CONTRACTOR IN ESTABLISHING AREAS REQUIRING
DISCONNECTION, REMOVAL, OR RELOCATION OF ELECTRICAL EQUIPMENT,
OUTLETS, WIRING, DEVICES, FIXTURES, ETC. AND MAY NOT INDICATE ALL
DEVICES OR THE FULL EXTENT OF DEMOLITION AND RECONNECTION WHICH
MAY BE REQUIRED. THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB
SITE AND THOROUGHLY EXAMINE ALL REQUIRED DEMOLITION WORK AND
INCLUDE ALL LABOR AND INCIDENTALS THAT WILL BE NECESSARY TO
PERFORM DEMOLITION RECONNECTION AND TEMPORARY POWER
CONNECTIONS IN THE BID.
H. ALL ELECTRICAL DEVICES AND WALLS INDICATED ON THE ELECTRICAL
DEMOLITION DRAWING(S) ARE TO REMAIN UNLESS OTHERWISE NOTED.
USB DUPLEX CONVENIENCE OUTLET, +18" AFF UNO
USB FOURPLEX CONVENIENCE OUTLET, +18" AFF UNO
RECESSED ENTERTAINMENT BOX
SINGLE FACE EXIT SIGN, CEILING MOUNTED PROVIDE UNSWITCHED
CONDUCTOR.
WALL MOUNTED SINGLE FACE EXIT SIGN WITH EMERGENCY EGRESS
LIGHTING. PROVIDE UNSWITCHED CONDUCTOR. MOUNT AT +8'-0" UNO.
CEILING MOUNTED. SINGLE FACE EXIT SIGN WITH EMERGENCY
EGRESS LIGHTING. PROVIDE UNSWITCHED CONDUCTOR.
CEILING MOUNTED. DOUBLE FACE EXIT SIGN WITH EMERGENCY
EGRESS LIGHTING. PROVIDE UNSWITCHED CONDUCTOR.
HUMIDISTAT, +46" AFF PROVIDE CONDUIT, J-BOX, CONDUCTORS AS
REQUIRED TO CONTROL ASSOCIATED UNITS.
15
15
15
BS,BR
H HEAT
I IONIZATION
ID IN DUCT
P PHOTOELECTRIC
R RELAY
WG PROVIDE PROTECTIVE WIRE GUARD
PULL STATION, +44" AFF WITH PRE-ALARM COVER
FIRE ALARM HORN, +84" AFF UNO
FIRE ALARM STROBE, +84" AFF UNO, STROBE INTENSITY INDICATED. 'C'
INDICATES CEILING MOUNTED
FIRE ALARM HORN/STROBE +84" AFF, UNO, STROBE INTENSITY
INDICATED. 'C' INDICATES CEILING MOUNTED
FIRE ALARM BELL, +84" AFF UNO. 'C' INDICATES CEILING MOUNTED
FIRE ALARM CHIME, +84" AFF UNO. 'C' INDICATES CEILING MOUNTED
FIRE ALARM CHIME/STROBE, +84" AFF UNO, STROBE INTENSITY
INDICATED. 'C' INDICATES CEILING MOUNTED
END OF LINE RESISTOR
FLOW SWITCH, PROVIDE MONITOR MODULE AS REQUIRED
TAMPER SWITCH, PROVIDE MONITOR MODULE AS REQUIRED
PRESSURE SWITCH, PROVIDE MONITOR MODULE AS REQUIRED
FIRE SYSTEM ANNUNCIATOR, FLUSH MOUNTED +54"UNO
POST INDICATOR VALVE, PROVIDE MONITOR MODULE AS REQUIRED
ELECTROMAGNETIC DOOR HOLDER
FIRE/SMOKE DAMPER
LED INDICATOR LIGHT, CEILING MOUNTED UNO
SMOKE DETECTOR, CEILING MOUNTED UNO
BEAM DETECTOR, SENDER & RECEIVER
RELAY
LED INDICATOR LIGHT WITH TEST SWITCH, CEILING MOUNTED UNO
CONTROL MODULE
MONITOR MODULE
FIRE ALARM CONTROL PANEL
NAC EXTENDER PANEL
DUCT-MOUNTED SMOKE DETECTOR
FSA
FIRE ALARM KNOX BOX
SPEAKER STROBE, +84" AFF UNO. 'C' INDICATES CEILING MOUNTED
ST
N
GFP
#
PANEL
NAME
VOLTAGE
PHASE
#
#
#
#
#
TVSS
LSIGR
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
MU
S
G
R
O
V
E
E
N
G
I
N
E
E
R
I
N
G
,
P
A
64
5
W
.
2
5
T
H
S
T
.
ID
A
H
O
F
A
L
L
S
,
I
D
8
3
4
0
2
20
8
-52
3
-28
6
2
ww
w
.
m
u
s
g
r
o
v
e
p
a
.
c
o
m
PR
O
J
E
C
T
N
U
M
B
E
R
:
2
3
-19
9
7/
1
3
/
2
0
2
3
1
2
:
5
8
:
3
6
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
ELECTRICAL COVER
SHEET
23-010
LT
MB
06/29/2023
E0.00
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
07/13/2023
T
3
T
T
2
1D
1B
1A
D2 E E1D1DC3C1
1A
1B
1D
2
E1ED2D1DC3C1
OFFICE 2
215
OFFICE 1
216
OFFICE 3
217
GROUP ROOM
218
WAITING AREA
219
RECEPTION
220
12
121
2
1
2
1
2
2
2
2
1D
1B
1A
D2 E E1D1DC3C1
1A
1B
1D
2
E1ED2D1DC3C1
OFFICE 2
215
OFFICE 1
216
OFFICE 3
217
GROUP ROOM
218
WAITING AREA
219
RECEPTION
220
2
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
MU
S
G
R
O
V
E
E
N
G
I
N
E
E
R
I
N
G
,
P
A
64
5
W
.
2
5
T
H
S
T
.
ID
A
H
O
F
A
L
L
S
,
I
D
8
3
4
0
2
20
8
-52
3
-28
6
2
ww
w
.
m
u
s
g
r
o
v
e
p
a
.
c
o
m
PR
O
J
E
C
T
N
U
M
B
E
R
:
2
3
-19
9
7/
1
3
/
2
0
2
3
1
2
:
5
8
:
3
6
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
ELECTRICAL DEMO
PLAN
23-010
LT
MB
06/29/2023
E1.00
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
1/4" = 1'-0"E1.00
1 ELECTRICAL PLAN DEMO
1/4" = 1'-0"E1.00
2 LIGHTING PLAN DEMO
KEYED NOTES:
SYMBOL USED FOR CALLOUT#
1. DEMO DATA TO NEAREST J-BOX ABOVE DROP CEILING. MAINTAIN
CABLES IN LOOPS TO REUSE IN RENOVATION.
2. DEMO POWER TO NEAREST J-BOX ABOVE DROP CEILING.
07/13/2023
T
T
3
D
D
D
D D
S DIMMING SWITCH - WALL MOUNT, 120/277V, ON/OFF/DIM, 0-10V DIM
SENSOR SWITCH WSXA-PDT-D-XX OR EQUAL
XX=VERIFY COLOR WITH ARCHITECT PRIOR TO ORDER
SWITCH AND OCCUPANCY SENSOR LEGEND
EQUAL PRODUCTS FROM WATTSTOPER, LUTRON, LEGRAND, AND EATON WILL BE ACCEPTED
D
2
1D
1B
1A
D2 E E1D1DC3C1
1A
1B
1D
2
E1ED2D1DC3C1
OFFICE 2
215
OFFICE 1
216
OFFICE 3
217
GROUP ROOM
218
WAITING AREA
219
RECEPTION
220
2
1
3
1D -20
1D -24
1D -22
4
4
4
5
2
1D
1B
1A
D2 E E1D1DC3C1
1A
1B
1D
2
E1ED2D1DC3C1
OFFICE 2
215
OFFICE 1
216
OFFICE 3
217
GROUP ROOM
218
WAITING AREA
219
RECEPTION
220
1
1
1D -26
2
A A
A
A
A
A
A A
A A
A A
3 3
3
3
3
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
MU
S
G
R
O
V
E
E
N
G
I
N
E
E
R
I
N
G
,
P
A
64
5
W
.
2
5
T
H
S
T
.
ID
A
H
O
F
A
L
L
S
,
I
D
8
3
4
0
2
20
8
-52
3
-28
6
2
ww
w
.
m
u
s
g
r
o
v
e
p
a
.
c
o
m
PR
O
J
E
C
T
N
U
M
B
E
R
:
2
3
-19
9
7/
1
3
/
2
0
2
3
1
2
:
5
8
:
3
7
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
ELECTRICAL INSTALL
PLAN
23-010
LT
MB
06/29/2023
E2.00
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
1/4" = 1'-0"1 ELECTRICAL PLAN INSTALL
1/4" = 1'-0"2 LIGHTING PLAN INSTALL
KEYED NOTES:
SYMBOL USED FOR CALLOUT#
1. REROUTE CABLE FROM NETWORK JACK BELOW IN WALL TO CCTV
CAMERA.
2. RELOCATE EXISITNG POWER/DATA TO 42" AFF
3. SEE DETAIL 1 ON SHEET E3.00 FOR RECESSED ENTERTAINMENT BOX
DETAIL.
4. CONTRACTOR TO FIELD VERIFY CIRCUIT.
5. CONNECT TO EXISTING FAN COIL BRANCH CIRCUIT
KEYED NOTES:
SYMBOL USED FOR CALLOUT#
1. CONNECT BOTH SWITCHLEGS TOGTHER, PROVIDE AND INSTALL
2-GANG BLANK+DECORA COVER.
2. CONTRACTOR TO FIELD VERIFY CIRCUIT.
3. PROVIDE AND INSTALL 0-10V DIMMING CONDUCTORS FROM SWITCH
TO LIGHT FIXTURES IN THE ZONE.
12" = 1'-0"3 CONTROL SCHEDULE
07/13/2023
TV
FLAT SCREEN
WALL STUD
STUB UP 4"ABOVE CEILING ACCESSIBLE CEILING
VA
R
I
E
S
TOP PLATE
FINISHED FLOOR
FLOOR PLATE
INSTALL CONDUIT STRAP
AS REQUIRED BY NEC
(TYPICAL)
70
"
ELECTRICAL CONTRACTOR RESPONSIBLE FOR
INSTALLATION OF REB ROUGH-IN
TYPICAL DETAIL - ACTUAL INSTALLATION MAY VARY
18
"
5" SQUARE JUNCTION BOX
WITH SINGLE GANG MUDRING
RANDL TB55057 OR EQUAL
SINGLE GANG DEVICE COVER
RANDL D-51GO12 OR EQUAL
1 1/4"C PVC WITH PULLSTRING
FOR DATA/COMMUNICATIONS
TO ELECTRICAL PANEL BOARD
1"C EMT FOR POWER
CONDUCTORS AS SHOWN ON
POWER DRAWINGS
ANTI-SHORT PLASTIC BUSHING
ARLINGTON INDUSTRIES EMT100
OR EQUAL
1 1/4"C PVC WITH PULLSTRING
FOR DATA/COMMUNICATIONS
RECESSED ENTERTAINMENT BOX:
WIREMOLD:
1- EHWB4
1- EHWBC4-XX COVER
1 EXTRA- EFB810-3/4-11/4
OR EQUAL
XX = COLOR TO BE CONFIRMED BY
ARCHITECT
DOUBLE DUPLEX DEVICE PLATE
AND TWO DUPLEX RECEPTACLES
SINGLE GANG DATA DEVICE PLATE
EXIT
T S
1. PROVIDE FRAMING AS REQUIRED.
FINISHED CEILING
FINISHED
FLOOR
DETAIL GENERAL NOTES:
+18"A.F.F.
+46"A.F.F.
+84"A.F.F.
+96"A.F.F.
EMERGENCY
LIGHT FIXTURE
(U.N.O.)
FIRE ALARM NOTIFICATION DEVICE (U.N.O.)
TEMPERATURE SENSOR (U.N.O.)
THERMOSTAT (U.N.O.)
FIRE ALARM PULL-STATION (U.N.O.)
+48" GFI DUPLEX RECEPTACLE (U.N.O.)
DUAL SWITCH (U.N.O.)
SINGLE SWITCH (U.N.O.)
QUAD RECEPTACLE (U.N.O.)
HORIZONTAL DUPLEX RECEPTACLE (U.N.O.)
DUPLEX RECEPTACLE (U.N.O.)
HORIZONTAL DATA OUTLET (U.N.O.)
DATA OUTLET (U.N.O.)
INTERCOM PANEL (U.N.O.)
CENTER LOCAL DISCONNECT
AT INTERIOR FAN COIL HEIGHT.
(SWITCH TO BE KEYED SWITCH)
INTERIOR FAN COIL UNIT
EXIT SIGN +12" ABOVE DOOR FRAME (U.N.O)
P
r
o
j
e
c
t
:
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP
PIVOT NORTH ARCHITECTURE
116 SOUTH 6TH STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
MU
S
G
R
O
V
E
E
N
G
I
N
E
E
R
I
N
G
,
P
A
64
5
W
.
2
5
T
H
S
T
.
ID
A
H
O
F
A
L
L
S
,
I
D
8
3
4
0
2
20
8
-52
3
-28
6
2
ww
w
.
m
u
s
g
r
o
v
e
p
a
.
c
o
m
PR
O
J
E
C
T
N
U
M
B
E
R
:
2
3
-19
9
7/
1
3
/
2
0
2
3
1
2
:
5
8
:
3
8
P
M
MM
H
B
e
h
a
v
i
o
r
a
l
H
e
a
l
t
h
T
I
37
S
2
N
D
S
T
R
E
E
T
E
A
S
T
,
R
E
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
ELECTRICAL DETAILS
& SCHEDULES
23-010
LT
MB
06/29/2023
E3.00
PE
R
M
I
T
S
E
T
:
0
7
.
1
3
.
2
0
2
3
1" = 1'-0"1 RECESSED ENTERTAINMENT BOX
1" = 1'-0"2 STANDARD MOUNTING HEIGHT
07/13/2023