LOAD SHORT FORM - 23-00433 - 687 S 2275 W - New SFR
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Jul-07 09:09:17 Rig ht-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 1 ...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Load Short Form Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1476Design TD (°F) H-Daily range 5050Inside humidity (%) -3162Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMH950703BX Cond GSX130241C* AHRI ref 2002183 Coil Capf3030bx AHRI ref 4765510 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh69000 Sensible cooling Btuh16100 Heating output Btuh52440 Latent cooling Btuh6900 Temperature rise °F62 Total cooling Btuh23000 Actual air flow cfm920 Actual air flow cfm767 Air flow factor cfm/Btuh0.028 Air flow factor cfm/Btuh0.072 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room1 604 13506 3672 375 266 Room2 52 0 0 0 0 Room3 150 2249 271 62 20 Room4 250 3448 1345 96 97 Room5 242 2078 1378 58 100 Room6 169 2843 1405 79 102 Room7 50 589 85 16 6 Room8 154 2184 1085 61 79 Room9 132 2831 1120 79 81 Room10 35 632 46 18 3 Room11 82 2770 184 77 13 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Jul-07 09:09:17 Rig ht-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 2 ...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N Entire House d 1920 33130 10590 920 767 Other equip loads 1821 335 Equip. @ 0.94 RSM 10270 Latent cooling 0 TOTALS 1920 34950 10270 920 767 2023-Jul-07 09:09:17 Rig ht-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 1 ...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Building Analysis Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 31.8111194.9Walls 14.3499223.7Glazing 2.690022.0Doors 5.117771.5Ceilings 12.142283.63.6Floors 28.9101144.0Infiltration 00Ducts 00Piping 00Humidification 5.21821Ventilation0Adjustments 100.034950Total Cooling Walls Glazing Doors Ceilings Other InfiltrationVentilation % of loadBtuhBtuh/ft²Component 9.810680.5Walls 66.1721834.3Glazing 2.02195.4Doors 9.09820.8Ceilings 1.21340.1Floors 8.99690.4Infiltration 00Ducts 3.1335Ventilation 00Internal gains 00Blower 0Adjustments 100.010925Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 63 Btuh/ft²-°F Data entries checked. 2023-Jul-07 09:09:17 Rig ht-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 1 ...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Component Constructions Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 380.474004.9421.00.06581n 560.475784.9421.00.065117w 940.479784.9421.00.065198all Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 2390.4724904.9422.00.065504n 2470.4725754.9422.00.065521e 2780.4728904.9422.00.065585s 2100.4721874.9422.00.065443w 9740.47101414.9422.00.0652053all Partitions (none) Windows 61C: 61C; 6.67 ft head ht 85434.157022.800.30025e 272034.4192124.300.32079e 192334.1128422.800.30056w 172134.4121624.300.32050w 721834.3499223.700.320210all Doors 11P0: Door, mtl pur core type 2195.3790022.010.50.29041e Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 9820.8417771.5250.00.0201169 Floors 19A-30bscp: Part floor, carpet flr fnsh, r-30 ins, frm flr, 12" thkns, 1/2" gypsum board int fnsh 1340.407292.1730.00.034336 21A-24t: Bg floor, heavy dry or light damp soil, 6' depth 00.025117 002221.90 22B-10cpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10 edge ins, carpet flr fnsh 00318427.010.00.355118 009427.010.00.3553 00327727.010.00.355121all 2023-Jul-07 09:09:17 Rig ht-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 2 ...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Jul-07 09:09:17 Rig ht-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 1 ...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Project Summary Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F70 Inside db °F75 Design TD °F76 Design TD °F14Daily range H Relative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh33130 Structure Btuh10590 Ducts Btuh0 Ducts Btuh0Central vent (26 cfm)1821 Btuh Central vent (26 cfm)Btuh335 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh34950 Use manufacturer's data n Rate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh10270 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh-1347 Ducts Btuh0Central vent (26 cfm)Btuh-466 CoolingHeating Outside air19201920Area (ft²)Equipment latent load Btuh0 1728017280Volume (ft³)Air changes/hour 0.260.50 Equipment Total Load (Sen+Lat)Btuh10270 Equiv. AVF (cfm)75144 Req. total capacity at 0.70 SHR ton1.2 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg.Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMH950703BX Cond GSX130241C*AHRI ref 2002183 Coil Capf3030bx AHRI ref 4765510Efficiency95 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh69000 Sensible cooling Btuh16100Heating output Btuh52440 Latent cooling Btuh6900 Temperature rise °F62 Total cooling Btuh23000Actual air flow cfm920 Actual air flow cfm767 Air flow factor cfm/Btuh0.028 Air flow factor cfm/Btuh0.072Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 2023-Jul-07 09:09:17 Rig ht-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 1 ...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:AED Assessment Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) )H(34-Da ily ra nge (°F) 60-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 29.7%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Jul-07 09:09:17Right-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 1...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Entire House Room1 2 Exposed wall 278.0 ft 101.0 ft 3 Room height 9.0 dft 9.0 heat/coolft 4 Room dimensions ft604.0x1.0 5 Room area 1920.0 f t²604.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.944.94 0.470.47 81 81 400 38 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 504 504 2490 239 180 180 889 85 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 666 521 2575 247 216 150 742 71 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 25 0 570 854 25 0 570 854 1 1 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 79 0 1921 2720 0 0 0 0 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 41 41 900 219 41 41 900 219 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 585 585 2890 278 297 297 1467 141 WW 12F-0sw12F-0sw 0.0650.065 ww 4.944.94 0.470.47 117 117 578 56 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 549 443 2187 210 216 160 789 76 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 56 0 1284 1923 56 0 1284 1923 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 50 0 1216 1721 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 1169 1169 1777 982 22 22 33 18 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 336 336 729 134 0 0 0 0 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 117 117 222 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 656 118 3184 0 604 101 2725 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 60 3 94 0 0 0 0 0 6 c) AED excursion 0 -95 Envelope loss/gain 23016 9621 9400 3293 12 a)Infiltration 10114 969 3675 352 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)33130 10590 13074 3645 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 431 26 14 Subtotal 33130 10590 13506 3672 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 33130 10590 13506 3672 Air required (cfm)Air required (cfm)920 767 375 266 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Jul-07 09:09:17Right-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 2...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room2 Room3 2 Exposed wall 17.0 ft 25.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft4.0x13.0 ft15.0x10.0 5 Room area 52.0 f t²150.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 36 36 178 17 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 117 117 578 56 0 0 0 0 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 1 1 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 135 135 667 64 WW 12F-0sw12F-0sw 0.0650.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 90 90 445 43 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 0 0 0 0 150 150 228 126 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 52 17 459 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -20 -49 Envelope loss/gain 1214 52 1339 183 12 a)Infiltration 618 59 910 87 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1833 112 2249 271 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -1833 -112 0 0 14 Subtotal 0 0 2249 271 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 2249 271 Air required (cfm)Air required (cfm)0 0 62 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Jul-07 09:09:17Right-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 3...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room4 Room5 2 Exposed wall 31.0 ft 14.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft250.0x1.0 ft242.0x1.0 5 Room area 250.0 f t²242.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 135 106 524 50 0 0 0 0 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 1 1 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 29 0 705 998 0 0 0 0 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 144 144 711 68 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 126 101 499 48 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 25 0 608 861 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 250 250 380 210 242 242 368 203 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 60 3 94 0 6 c) AED excursion -90 217 Envelope loss/gain 2320 1237 1568 1329 12 a)Infiltration 1128 108 509 49 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)3448 1345 2078 1378 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 3448 1345 2078 1378 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 3448 1345 2078 1378 Air required (cfm)Air required (cfm)96 97 58 100 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Jul-07 09:09:17Right-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 4...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room6 Room7 2 Exposed wall 26.0 ft 5.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft13.0x13.0 ft5.0x10.0 5 Room area 169.0 f t²50.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 117 117 578 56 45 45 222 21 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 1 1 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 117 92 454 44 0 0 0 0 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 25 0 608 861 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 169 169 257 142 50 50 76 42 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 50 50 108 20 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 212 -16 Envelope loss/gain 1897 1314 407 68 12 a)Infiltration 946 91 182 17 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2843 1405 589 85 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2843 1405 589 85 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2843 1405 589 85 Air required (cfm)Air required (cfm)79 102 16 6 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Jul-07 09:09:17Right-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 5...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room8 Room9 2 Exposed wall 14.0 ft 23.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft14.0x11.0 ft12.0x11.0 5 Room area 154.0 f t²132.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 18 18 89 9 108 108 534 51 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 99 74 366 35 99 74 366 35 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 1 1 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 25 0 608 861 25 0 608 861 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 9 9 44 4 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 154 154 234 129 132 132 201 111 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 154 154 334 62 132 132 286 53 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -64 -70 Envelope loss/gain 1675 1036 1994 1040 12 a)Infiltration 509 49 837 80 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2184 1085 2831 1120 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2184 1085 2831 1120 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2184 1085 2831 1120 Air required (cfm)Air required (cfm)61 79 79 81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-Jul-07 09:09:17Right-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 6...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Right-J® W or ksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room10 Room11 2 Exposed wall 7.0 ft 15.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.0x7.0 ft82.0x1.0 5 Room area 35.0 f t²82.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.944.94 0.470.47 0 0 0 0 81 81 400 38 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3000.300 ee 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 1 1 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD 11P011P0 0.2900.290 ee 22.0422.04 5.365.36 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.944.94 0.470.47 63 63 311 30 54 54 267 26 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 0 0 0 0 0 0 0 0 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 35 35 66 0 82 82 156 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -8 -18 Envelope loss/gain 378 22 823 46 12 a)Infiltration 255 24 546 52 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)632 46 1368 98 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 1402 85 14 Subtotal 632 46 2770 184 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 632 46 2770 184 Air required (cfm)Air required (cfm)18 3 77 13 Job #: SF3B12 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryhtg@gmail.com Scale: 1 : 62 Page 1 Ri ght-Suit e ® Un iv ersal 2022 22.0.05 RSU20477 2023-Jul-07 09:09:36 ...oft Program\SF3B12 princeton.rup N 2nd Story Room3 Room4 Room5 Room6 Room7 Room8 Room9 100 cfm 79 cfm 158 cfm 106 cfm 49 cfm 62 cfm 49 cfm 102 cfm 16 cfm 79 cfm 81 cfm 102 cfm 81 cfm 6" mechanical fresh air damper Job #: SF3B12 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryhtg@gmail.com Scale: 1 : 62 Page 2 Ri ght-Suit e ® Un iv ersal 2022 22.0.05 RSU20477 2023-Jul-07 09:09:36 ...oft Program\SF3B12 princeton.rup N Main Floor Room1 Room2 Room10 Room11 36'-0" 6 " 94 cfm 94 cfm 94 cfm 94 cfm 18 cfm 77 cfm 470 cfm 6 " 14x3.25 6 " 14x3.25 12 x 8 6 " 14x3.25 6 "6 " 6 " 6 "6 " 6 " 6 "6 " 20 x 8 20 x 8 3-14x3.25 14x3.25 14x3.25 12 x 8 6 " 12 x 8 6 " 2023-Jul-07 09:09:18 Rig ht-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 1 ...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N SF3B12Job:Duct System Summary Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.34in H2O0.34 Available static pressure in H2O0.36in H2O0.36 Supply / return available pressure 0.177 / 0.183 in H2O in H2O0.177 / 0.183 Lowest friction rate in/100ft0.081in/100ft0.081 Actual air flow cfm767cfm920 Total effective length (TEL)ft445 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st1B180.039.0ShMt0x06.00.08166943376hRoom1 st1150.023.0ShMt0x06.00.10266943376hRoom1-A st1B170.049.0ShMt0x06.00.08166943376hRoom1-B st1A180.038.0ShMt0x06.00.08166943376hRoom1-C st1165.012.0ShMt0x06.00.100318632hRoom10 st1175.011.0ShMt0x06.00.09513772770hRoom11 st1A150.038.0ShMt0x06.00.09420622249hRoom3 st1A170.041.0ShMt0x06.00.0844948673cRoom4 st1A160.046.0ShMt0x06.00.0864948673cRoom4-A st1130.025.0ShMt0x06.00.114100581378cRoom5 st1160.016.0ShMt0x06.00.101102791405cRoom6 st1175.09.0ShMt0x06.00.096616589hRoom7 st1140.033.0ShMt0x06.00.10279611085cRoom8 st1175.020.0ShMt0x06.00.09181791120cRoom9 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 920 767 0.081 828 13.7 20x8 ShtMetl st1A Peak AVF 439 316 0.081 659 10.6 12x8 ShtMetl st1 st1B Peak AVF 188 133 0.081 281 7.7 12x8 ShtMetl st1A 2023-Jul-07 09:09:18 Rig ht-Su ite® U niv er sal 20 22 22 .0.05 RSU2 0477 Page 2 ...Country\Wrightsoft Program\SF3B12 princeton.rup Calc = MJ8 House faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb2 0x 790 102 105.0 0.174 322 5.2 3.25x14 10x9 SJSp rt1 rb4 0x 610 79 96.0 0.190 249 4.7 3.25x14 10x9 SJSp rt1 rb3 0x 790 81 127.0 0.144 257 5.0 3.25x14 10x9 SJSp rt1 rb1 0x 4700 283 226.0 0.081 495 10.8 3-3.25x14 3-10x27 SJSp rt1 rb6 0x 740 106 141.0 0.130 335 5.6 3.25x14 10x9 SJSp rt1 rb5 0x 1580 117 194.0 0.094 501 7.0 3.25x14 10x9 SJSp rt1A Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 920 767 0.081 828 13.7 20x8 ShtMetl rt1A Peak AVF 158 117 0.094 237 7.0 12x8 ShtMetl rt1