HomeMy WebLinkAboutCONCRETE FIELD TESTS - 22-00610 - U-Haul - New Commercial Bldg A & BFile Name 22247C12072022CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 572538EC-49EE-4433-8485-B3122C9C91F7 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 02793 Project Name: U-Haul Moving and Storage Test Location: Footings, Southeast corner Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Required 28 day Strength (psi): 3,500.0 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-170FI U Date: 12/07/2022 Start Time 10:00 AM End Time 01:45 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 11:15 AM 02793 Footings, Southeast corner 24 143.5 1.7 N/A 60 8 Max 2 12:15 PM 02797 50 feet west of the northeast corner of the footings 26 145.1 2.1 N/A 57 8 M Observations/Remarks: I arrived on site and began observations on the reinforcement for the footings from the southeast corner to the northeast corner and to 300 feet west of the northeast corner of the main building. I looked for overlap, clearance, correctness, and overall uniformity. I also made sure the reinforcement was lifted off the ground. I observed that the reinforcement was within general conformance to project guidelines. I observed the contractor manually tie the reinforcement and place it on the ground. When I arrived I noted that the area being poured had been covered with concrete blankets the night before. At 11:10 AM the first truck arrived and I took a sample after approximately one yard had been expelled from the File Name 22247C12072022CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 572538EC-49EE-4433-8485-B3122C9C91F7 2 truck. I performed a concrete field test and observed that the results of the test were within general conformance to project guidelines. I proceeded to take another sample from the fifth truck after approximately one yard had been expelled from the truck. With this sample I performed a concrete field test. I observed the results of the test within general conformance to project guidelines. With each sample I made concrete test specimens and placed them in a cooler with heated water near the footings to be covered with blankets and heated, I remained on site for the duration of the pour and reported my results to the contractor then left the site. Tested By: C Hammar Signature: Reviewed By: Luke Hammar Signature: Date: 12/07/2022 Inspection Images File Name 22247C12072022CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 572538EC-49EE-4433-8485-B3122C9C91F7 3 File Name 22247C12132922CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 34A600D4-A292-473B-88A6-7BCF77EE0426 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 02871 Project Name: U-Haul Moving and Storage Test Location: Footings southwest section of building Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Required 28 day Strength (psi): 3,500.0 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-170FI U Date: 12/13/2022 Start Time 11:00 AM End Time 02:00 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 12:00 PM 02871 Footings southwest section of building 28 145.0 1.7 N/A 59 8 Max Observations/Remarks: Arrived on site and began observations on the reinforcement for half of the northern side of the footings and the entirety of the western side. I looked for uniformity, overlap, clearance, and overall correctness. I observed that the reinforcement was within general conformance to project guidelines, and that it was lifted up and off the ground. I observed that the contractor covered and heated the ground preparatory to concrete poured today. The truck arrived at 11:55 AM and I took a sample at 12:00 PM. with the sample I performed a concrete field test and made concrete test specimens. I observed the results of the tests were within general conformance to project guidelines, and I reported my results to the contractor. I left the concrete test specimens in a cooler with heated water next to the footings to be covered and heated overnight then left the jobsite. File Name 22247C12132922CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 34A600D4-A292-473B-88A6-7BCF77EE0426 2 Tested By: C Hammar Signature: Reviewed By: Luke Hammar Signature: Date: 12/14/2022 Inspection Images File Name 22247C12132922CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 34A600D4-A292-473B-88A6-7BCF77EE0426 3 File name: 22247CFB12142022CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 4A1F2855-7B11-40A5-86BB-78F16807A7A2 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: 50 feet west of the northeast corner of the footings Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 2797 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-170FI U Date: 12/7/2022 Cylinder Log #: 791 Field Test Results: Set #: 2 Slump Maximum (in): Entrained Air (%): 2.1 Entrained Air Spec. (%): Concrete Temperature (°F): 57 Ambient Temperature (°F): 26 Unit Weight (PCF): 145.1 Tested By: C. Hammar Date: 12/7/2022 Picked Up By: E. Vail Date: 12/9/2022 Time: 10:15 AM Max, Min Temperature 91, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/14/2022 4.000 12.56 34,210.0 2724 3,500.0 Type 1 Date: 12/14/2022 Reviewed By: Luke Hammar Signature: File name: 22247CFB12142022CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9C19DE98-94D3-4F40-AD4A-F2C5D4D02698 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Footings, Southeast corner Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 2793 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-170FI U Date: 12/7/2022 Cylinder Log #: 790 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.7 Entrained Air Spec. (%): Concrete Temperature (°F): 60 Ambient Temperature (°F): 24 Unit Weight (PCF): 143.5 Tested By: C. Hammar Date: 12/7/2022 Picked Up By: E. Vail Date: 12/9/2022 Time: 10:00 AM Max, Min Temperature 91, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/14/2022 4.000 12.56 46,555.0 3707 3,500.0 Type 6 Date: 12/14/2022 Reviewed By: Luke Hammar Signature: File Name 22247C12162022CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1893123A-4D83-4D44-BD82-A39D6806204B 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 02914 Project Name: U-Haul Moving and Storage Test Location: Western most footing Client: Bateman-Hall Admixtures: NA Required 28 day Strength (psi): 3,500.0 Contractor: Bryan Landon Supplier: Walter’s Ready Mix Mix Number: W-170FI U Date: 12/16/2022 Start Time 11:30 AM End Time 02:00 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 12:30 PM 02914 Western most footing 14 145.0 1.7 N/A 51 8 Max Observations/Remarks: I arrived on site and began observations on the footings north and west for the main building. When I arrived the third truck was in the middle of pouring and almost finished. I waited to take a test from the fourth truck. At 12:25 PM I received a sample after approximately 1 yard had been expelled from the fourth truck. With the sample I performed a concrete field test and made concrete test specimens. I observed that the results of the test were within general conformance to project guidelines. I reported my results to the contractor and left the job site. Prior to pouring I noted that the contractor had covered the ground to be poured and had heated it overnight. Tested By: C Hammar Signature: Reviewed By: Luke Hammar Signature: File Name 22247C12162022CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1893123A-4D83-4D44-BD82-A39D6806204B 2 Date: 12/16/2022 Inspection Images File name: 22247FB12202022EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5AE4E250-6253-42D1-B655-DF7B0079650C 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11 Project Name: U-Haul Moving and Storage Test Location: Footings southwest section of building Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 2871 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-170FI U Date: 12/13/2022 Cylinder Log #: 797 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.7 Entrained Air Spec. (%): Concrete Temperature (°F): 59 Ambient Temperature (°F): 28 Unit Weight (PCF): 145 Tested By: C. Hammar Date: 12/13/2022 Picked Up By: Ben E Ball Date: 12/14/2022 Time: 10:11 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/20/2022 4.000 12.56 48,290.0 3845 3,500.0 Type 1 Date: 12/21/2022 Reviewed By: Luke Hammar Signature: File Name 22247C12232022CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 101D9E1B-D0F4-43A8-B279-DBAD01E7CDD6 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 5.0 Ticket #: 02951 Project Name: U-Haul Moving and Storage Test Location: Small foundation wall interior middle Client: Bateman-Hall Admixtures: X-SEED, MS AC 534, MP 322, MA AE 90 Required 28 day Strength (psi): 3,500.0 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W172F 350 Date: 12/23/2022 Start Time 09:00 AM End Time 12:30 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 10:50 AM 02951 Small foundation wall interior middle 11 137.4 7.8 6 +- 1.5 54 8 Max Observations/Remarks: I arrived on site and began observations on the interior square foundation wall in the north middle of the main building. The concrete truck arrived at 10:45 AM and I received a sample at 10:50 AM after approximately 1 yard had been expelled from the truck. With the sample, I performed a concrete field test and made concrete test specimens. I noted that the air was a little high and informed the contractor who proceeded with the pour I observed that the results of the tests were within general conformance to project guidelines. I reported my results to the contractor and left the jobsite. Tested By: C Hammar Signature: Reviewed By: Luke Hammar Signature: File Name 22247C12232022CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 101D9E1B-D0F4-43A8-B279-DBAD01E7CDD6 2 Date: 12/27/2022 Inspection Images File Name 22247C12212022MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C25D7150-A6E6-4BE1-AA60-08354D6F19AA 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 02943 Project Name: U-Haul Moving and Storage Test Location: Pad footing southeast corner of job Client: Bateman-Hall Admixtures: MS AC 534, MP322 Required 28 day Strength (psi): 3,500.0 Contractor: BL construction Supplier: Walters Mix Number: W-17OFI U Date: 12/21/2022 Start Time 10:00 AM End Time 12:30 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 11:15 AM 02943 Pad footing southeast corner of job 30 145.0 2.0 N/A 59 8 Max Observations/Remarks: I arrived at the job site and met with the foreman to discuss the pour. We also talked about a good place to setup for testing. I prepped my gear and waited for the first truck to arrive. The first truck arrived around 10:45, I grabbed my ticket and waited the allotted time to grab my sample. I did so and returned to my work area to begin my testing. My results were within spec and I reported to both the driver and the foreman. I returned to my vehicle to clean my gear. I observed the remainder of the pour and began my report. I left the job site around 12:45. Tested By: M.Mansfield Signature: Reviewed By: Luke Hammar Signature: File Name 22247C12212022MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C25D7150-A6E6-4BE1-AA60-08354D6F19AA 2 Date: 12/27/2022 Inspection Images File name: 22247CFB12232022CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BA461E35-4F45-42AB-B870-17421A24AB5C 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11 Project Name: U-Haul Moving and Storage Test Location: Western most footing Client: Bateman-Hall Admixtures: N/A Ticket Number: 2914 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-170FI U Date: 12/16/2022 Cylinder Log #: 806 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.7 Entrained Air Spec. (%): Concrete Temperature (°F): 51 Ambient Temperature (°F): 14 Unit Weight (PCF): 145 Tested By: C. Hammar Date: 12/16/2022 Picked Up By: M.Mansfield Date: 12/17/2022 Time: 3:23 PM Max, Min Temperature 80,60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/23/2022 4.000 12.56 55,615.0 4428 3,500.0 Type 6 Date: 12/28/2022 Reviewed By: Luke Hammar Signature: File name: 22247FB12282022LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F866B0AD-F362-4C3E-8CC2-02DE02C2497C 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11 Project Name: U-Haul Moving and Storage Test Location: Pad footing southeast corner of job Client: Bateman-Hall Admixtures: MS AC 534, MP322 Ticket Number: 2943 Contractor: BL construction Supplier: Walters Mix Number: W-17OFI U Date: 12/21/2022 Cylinder Log #: 809 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 2.0 Entrained Air Spec. (%): Concrete Temperature (°F): 59 Ambient Temperature (°F): 30 Unit Weight (PCF): 145 Tested By: M.Mansfield Date: 12/21/2022 Picked Up By: C Hammar Date: 12/27/2022 Time: 10:08 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/28/2022 4.000 12.56 65,780.0 5237 3,500.0 Type 2 Date: 12/29/2022 Reviewed By: Luke Hammar Signature: File Name 22247C01062023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 62BFEA64-A3C1-4BA7-8B57-C2667FCB957B 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 03005 Project Name: U-Haul Moving and Storage Test Location: Southern foundation wall Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Required 28 day Strength (psi): 3,500.0 Contractor: BL Construction Supplier: Walters Mix Number: W-170FI U Date: 01/06/2023 Start Time 11:00 AM End Time 02:30 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 12:00 PM 03005 Southern foundation wall 35 145.9 1.2 N/A 51 8 Max 2 01:30 PM 03009 Southern foundation walls 35 145.4 1.5 6 +- 1.5 58 8 Max Observations/Remarks: I arrived at the job site around 11:30 am and began a rebar inspection. I found the rebar to be up to spec. I performed other tasks while waiting for the first truck. The first truck arrived around 12:00 pm and I was able to grab a ticket from the driver and then waited for her to have a yard off. Once a yard was discharged I was able to grab a sample and begin testing, the results were within spec and reported to both the driver and the foreman. I poured my cylinders and then cleaned my gear in preparation for my second test. The fifth truck arrived around 1:15 pm and I was able to grab a sample and begin testing around 1:30 pm. The results were also within spec. I placed my cylinders and began cleaning my gear. I observed the remainder of the pour. File Name 22247C01062023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 62BFEA64-A3C1-4BA7-8B57-C2667FCB957B 2 Once the pour was concluded I returned to my vehicle to fill out my report. I left the job around 2:30 pm. Tested By: M.Mansfield Signature: Reviewed By: E. Vail Signature: Date: 01/09/2023 Inspection Images File Name 22247C01062023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 62BFEA64-A3C1-4BA7-8B57-C2667FCB957B 3 File name: 22247SB01052023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8E7CCD2C-4598-4D06-995F-A3145584AAF4 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: 50 feet west of the northeast corner of the footings Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 2797 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-170FI U Date: 12/7/2022 Cylinder Log #: 791 Field Test Results: Set #: 2 Slump Maximum (in): Entrained Air (%): 2.1 Entrained Air Spec. (%): Concrete Temperature (°F): 57 Ambient Temperature (°F): 26 Unit Weight (PCF): 145.1 Tested By: C. Hammar Date: 12/7/2022 Picked Up By: E. Vail Date: 12/9/2022 Time: 10:15 AM Max, Min Temperature 91, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/14/2022 12.56 34210 2724 3,500.00 Type 1 File name: 22247SB01052023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8E7CCD2C-4598-4D06-995F-A3145584AAF4 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 1/4/2023 4.000 12.56 51,985.0 4139 3,500.0 Type 2 C 28 1/4/2023 4.000 12.56 50,230.0 3999 3,500.0 Type 1 D 28 1/4/2023 4.000 12.56 53,150.0 4232 3,500.0 Type 6 Second Break Average: 4123 Date: 01/11/2023 Reviewed By: E. Vail Signature: File name: 22247SB01052023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1EB22F9C-3AE9-4FC9-852F-362CE18956DB 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Footings, Southeast corner Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 2793 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-170FI U Date: 12/7/2022 Cylinder Log #: 790 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.7 Entrained Air Spec. (%): Concrete Temperature (°F): 60 Ambient Temperature (°F): 24 Unit Weight (PCF): 143.5 Tested By: C. Hammar Date: 12/7/2022 Picked Up By: E. Vail Date: 12/9/2022 Time: 10:00 AM Max, Min Temperature 91, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/14/2022 12.56 46555 3707 3,500.00 Type 6 File name: 22247SB01052023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1EB22F9C-3AE9-4FC9-852F-362CE18956DB 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 1/4/2023 4.000 12.56 62,840.0 5003 3,500.0 Type 2 C 28 1/4/2023 4.000 12.56 61,050.0 4861 3,500.0 Type 2 D 28 1/4/2023 4.000 12.56 59,485.0 4736 3,500.0 Type 1 Second Break Average: 4866 Date: 01/11/2023 Reviewed By: E. Vail Signature: File name: 22247SB01102023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D0832665-E2B8-4A77-9E0C-6681B836EFFA 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Footings southwest section of building Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 2871 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-170FI U Date: 12/13/2022 Cylinder Log #: 797 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.7 Entrained Air Spec. (%): Concrete Temperature (°F): 59 Ambient Temperature (°F): 28 Unit Weight (PCF): 145.0 Tested By: C. Hammar Date: 12/13/2022 Picked Up By: Ben E Ball Date: 12/14/2022 Time: 10:11 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/20/2022 12.56 48290 3845 3,500.00 Type 1 File name: 22247SB01102023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D0832665-E2B8-4A77-9E0C-6681B836EFFA 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 1/10/2023 4.000 12.56 62,060.0 4941 3,500.0 Type 1 C 28 1/10/2023 4.000 12.56 61,915.0 4930 3,500.0 Type 2 D 28 1/10/2023 4.000 12.56 58,995.0 4697 3,500.0 Type 1 Second Break Average: 4856 Date: 01/11/2023 Reviewed By: E. Vail Signature: File Name 22247C01112023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 4F1818E5-5A26-4F96-B459-E511535A09F0 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 3022 Project Name: U-Haul Moving and Storage Test Location: Southwest corner of job Client: Bateman-Hall Admixtures: MP 355, MS AC 534 Required 28 day Strength (psi): 3,500.0 Contractor: Jerome Bowen Supplier: Walters Ready mix Mix Number: W-170FI U Date: 01/11/2023 Start Time 11:00 AM End Time 03:00 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 12:15 PM 3022 Southwest corner of job 37 146.3 1.3 N/A 61 8 Max 2 02:00 PM 3029 Southwest corner of job 34 146.9 1.0 N/A 62 8 Max Observations/Remarks: I arrived at the job site around 11:15 am and looked over the rebar and forms to make sure they were up to spec. I found that they were. I returned to my vehicle and setup my gear. I then waited for the first truck to show up. The first truck showed up just before 12:00 pm. I was able to grab the ticket and then waited for the driver to discharge a yard of material. Once that was accomplished I was able to grab my sample and begin testing. I found the material to be within spec and I was able to report those results to the foreman. I placed my cylinders and cleaned my gear in preparation for my next test. I observed the pour while I waited for the fifth truck to arrive. I saw that the crew was using vibration to consolidate the material as well as tapping on the forms. File Name 22247C01112023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 4F1818E5-5A26-4F96-B459-E511535A09F0 2 The fifth truck arrived around 1:45 pm and I was able to grab that ticket as well as the sample once the allotted time had passed. After running my tests I found the results to be within spec once again. I was able to pour my cylinders and place my cooler. Once I finished my work, I began cleaning my gear and returned to my vehicle. I began filling out my report. I left the job site at 3:00 pm. Tested By: M.Mansfield Signature: Reviewed By: E. Vail Signature: Date: 01/12/2023 Inspection Images File name: 22247SB01132023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 89B85E56-8AD6-4DBB-B852-6896B5AEA67D 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Western most footing Client: Bateman-Hall Admixtures: N/A Ticket Number: 2914 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-170FI U Date: 12/16/2022 Cylinder Log #: 806 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.7 Entrained Air Spec. (%): Concrete Temperature (°F): 51 Ambient Temperature (°F): 14 Unit Weight (PCF): 145.0 Tested By: C. Hammar Date: 12/16/2022 Picked Up By: M.Mansfield Date: 12/17/2022 Time: 3:23 PM Max, Min Temperature 80,60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/23/2022 12.56 55615 4428 3,500.00 Type 6 File name: 22247SB01132023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 89B85E56-8AD6-4DBB-B852-6896B5AEA67D 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 1/13/2023 4.000 12.56 64,150.0 5107 3,500.0 Type 1 C 28 1/13/2023 4.000 12.56 70,190.0 5588 3,500.0 Type 1 D 28 1/13/2023 4.000 12.56 67,850.0 5402 3,500.0 Type 2 Second Break Average: 5366 Date: 01/13/2023 Reviewed By: E. Vail Signature: File name: 22247FB01132023EV2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 425746A8-F8C2-4A61-8A9B-5ED3AB7DB1F5 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 55.0 Project Name: U-Haul Moving and Storage Test Location: Southern foundation walls Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 3009 Contractor: BL Construction Supplier: Walters Mix Number: W-170FI U Date: 1/6/2023 Cylinder Log #: 4 Field Test Results: Set #: 2 Slump Maximum (in): Entrained Air (%): 1.5 Entrained Air Spec. (%): Concrete Temperature (°F): 58 Ambient Temperature (°F): 35 Unit Weight (PCF): 145.4 Tested By: M.Mansfield Date: 1/6/2023 Picked Up By: M.Mansfield Date: 1/7/2023 Time: 9:00 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/13/2023 4.000 12.56 38,020.0 3027 3,500.0 Type 1 Date: 01/13/2023 Reviewed By: E. Vail Signature: File name: 22247FB01132023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 70ABD7F3-5E7B-4D7C-9E1A-D848A9A80439 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Southern foundation wall Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 3005 Contractor: BL Construction Supplier: Walters Mix Number: W-170FI U Date: 1/6/2023 Cylinder Log #: 3 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.2 Entrained Air Spec. (%): Concrete Temperature (°F): 51 Ambient Temperature (°F): 35 Unit Weight (PCF): 145.9 Tested By: M.Mansfield Date: 1/6/2023 Picked Up By: M.Mansfield Date: 1/7/2023 Time: 9:00 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/13/2023 4.000 12.56 42,365.0 3373 3,500.0 Type 2 Date: 01/13/2023 Reviewed By: E. Vail Signature: File name: 22247SB01182023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F3433CC1-8E63-436E-A4D0-294687BFB778 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Pad footing southeast corner of job Client: Bateman-Hall Admixtures: MS AC 534, MP322 Ticket Number: 2943 Contractor: BL construction Supplier: Walters Mix Number: W-17OFI U Date: 12/21/2022 Cylinder Log #: 809 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 2.0 Entrained Air Spec. (%): Concrete Temperature (°F): 59 Ambient Temperature (°F): 30 Unit Weight (PCF): 145.0 Tested By: M.Mansfield Date: 12/21/2022 Picked Up By: C Hammar Date: 12/27/2022 Time: 10:08 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/28/2022 12.56 65780 5237 3,500.00 Type 2 File name: 22247SB01182023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F3433CC1-8E63-436E-A4D0-294687BFB778 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 1/18/2023 4.000 12.56 77,030.0 6133 3,500.0 Type 2 C 28 1/18/2023 4.000 12.56 78,555.0 6254 3,500.0 Type 2 D 28 1/18/2023 4.000 12.56 75,970.0 6049 3,500.0 Type 1 Second Break Average: 6145 Date: 01/18/2023 Reviewed By: E. Vail Signature: File name: 22247FB01182023EV2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 3D7A3286-B651-4B06-88BD-4D2AB7D4B9AD 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 51.5 Project Name: U-Haul Moving and Storage Test Location: Southwest corner of job Client: Bateman-Hall Admixtures: MP 355, MS AC 534 Ticket Number: 3029 Contractor: Jerome Bowen Supplier: Walters Ready mix Mix Number: W-170FI U Date: 1/11/2023 Cylinder Log #: 10 Field Test Results: Set #: 2 Slump Maximum (in): Entrained Air (%): 1.0 Entrained Air Spec. (%): Concrete Temperature (°F): 62 Ambient Temperature (°F): 34 Unit Weight (PCF): 146.9 Tested By: M.Mansfield Date: 1/11/2023 Picked Up By: E. Vail Date: 1/13/2023 Time: 11:30 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/18/2023 4.000 12.56 39,605.0 3153 3,500.0 Type 1 Date: 01/18/2023 Reviewed By: E. Vail Signature: File name: 22247FB01182023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 3E945162-E51D-49FB-8F21-E7C683557A92 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Southwest corner of job Client: Bateman-Hall Admixtures: MP 355, MS AC 534 Ticket Number: 3022 Contractor: Jerome Bowen Supplier: Walters Ready mix Mix Number: W-170FI U Date: 1/11/2023 Cylinder Log #: 9 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.3 Entrained Air Spec. (%): Concrete Temperature (°F): 61 Ambient Temperature (°F): 37 Unit Weight (PCF): 146.3 Tested By: M.Mansfield Date: 1/11/2023 Picked Up By: E. Vail Date: 1/13/2023 Time: 11:15 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/18/2023 4.000 12.56 54,000.0 4299 3,500.0 Type 1 Date: 01/18/2023 Reviewed By: E. Vail Signature: File Name 22247C01192023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 4291A454-1DC8-4998-BB45-0841F716835F 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 33.0 Ticket #: 03084 Project Name: U-Haul Moving and Storage Test Location: Building B footings, 40’ north of SE corner. Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Required 28 day Strength (psi): 3,500.0 Contractor: Bateman-Hall Supplier: Walters Mix Number: W-170FI U Date: 01/19/2023 Start Time 09:00 AM End Time 12:00 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 09:45 AM 03084 Building B footings, 40’ north of SE corner. 23 141.4 1.2 N/A 56 8 Max 2 10:30 AM 03088 Building B footings, 10’ south of NE corner. 23 140.2 1.1 N/A 51 8 Max Observations/Remarks: I arrived on site around 9:30 am and was able to check in with Bateman-Hall to see where the best place to set up would be. I parked and set up my testing equipment. As we were given late notice, I was only able to obtain a sample from the third truck instead of the first. I tested for air, slump, and temp. All were within the given specs. After testing I made strength cylinders. I was also able to test the sixth truck in line and the results were acceptable as well. Results were passed on to Bateman-Hall as well as Walters Ready Mix. While observing the remainder of the pour, I noticed that mechanical vibration was being utilized throughout the pour. File Name 22247C01192023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 4291A454-1DC8-4998-BB45-0841F716835F 2 I left location at 11:45 am. Tested By: E. Vail Signature: Reviewed By: E. Vail Signature: Date: 01/19/2023 Inspection Images File name: 22247SB01202023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 85D70DB5-F492-437E-9AE2-9A829A3AE695 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 5.0 Project Name: U-Haul Moving and Storage Test Location: Small foundation wall interior middle Client: Bateman-Hall Admixtures: X-SEED, MS AC 534, MP 322, MA AE 90 Ticket Number: 2951 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W172F 350 Date: 12/23/2022 Cylinder Log #: 810 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 7.8 Entrained Air Spec. (%): Concrete Temperature (°F): 54 Ambient Temperature (°F): 11 Unit Weight (PCF): 137.4 Tested By: C. Hammar Date: 12/23/2022 Picked Up By: C Hammar Date: 12/27/2022 Time: 10:17 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 12/30/2022 12.56 36470 2904 3,500.00 Type 2 File name: 22247SB01202023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 85D70DB5-F492-437E-9AE2-9A829A3AE695 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 1/20/2023 4.000 12.56 46,815.0 3727 3,500.0 Type 1 C 28 1/20/2023 4.000 12.56 48,220.0 3839 3,500.0 Type 1 D 28 1/20/2023 4.000 12.56 49,195.0 3917 3,500.0 Type 3 Second Break Average: 3828 Date: 01/23/2023 Reviewed By: E. Vail Signature: File Name 22247C01252023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 6825D786-226E-440A-87A8-6A400B8E76A7 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 3156 Project Name: U-Haul Moving and Storage Test Location: Building D foundation wall. 15’ north of SE corner of building. Client: Bateman-Hall Admixtures: MS AC 534, MA AE 90, MP 322 Required 28 day Strength (psi): 3,500.0 Contractor: Bateman-Hall Supplier: Walters Mix Number: W172F 350 Date: 01/25/2023 Start Time 11:00 AM End Time 01:15 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 11:30 AM 3156 Building D foundation wall. 15’ north of SE corner of building. 13 138.8 5.9 6 +- 1.5 59 8 Max Observations/Remarks: I arrived on site around 10:30 am with enough time to look over the forms and rebar. Spacing and size appeared to be correct. Concrete showed up right on time at 11:00 am and after displacing a yard, I was able to obtain a sample for testing. I tested for air, slump, and temp. All were within spec. I reported that back to Walters and Bateman- Hall. After making strength cylinders I cleaned up my gear and observed the duration of the pour. I did notice that mechanical vibration was used on the walls. File Name 22247C01252023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 6825D786-226E-440A-87A8-6A400B8E76A7 2 Tested By: E. Vail Signature: Reviewed By: Luke Hammar Signature: Date: 01/26/2023 Inspection Images File name: 22247FB01262023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1CB74BB7-A6D0-46ED-B486-5F5802F95CB1 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 33 Project Name: U-Haul Moving and Storage Test Location: Building B footings, 40' north of SE corner. Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 3084 Contractor: Bateman-Hall Supplier: Walters Mix Number: W-170FI U Date: 1/19/2023 Cylinder Log #: 20 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.2 Entrained Air Spec. (%): Concrete Temperature (°F): 56 Ambient Temperature (°F): 23 Unit Weight (PCF): 141.4 Tested By: E. Vail Date: 1/19/2023 Picked Up By: Luke Hammar Date: 1/20/2023 Time: 10:01 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/26/2023 4.000 12.56 31,765.0 2529 3,500.0 Type 2 Date: 01/26/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB02012023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 488AC0D9-652F-4A8A-9B3D-6B78FC0C44BE 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11 Project Name: U-Haul Moving and Storage Test Location: Building D foundation wall. 15 north of SE corner of building. Client: Bateman-Hall Admixtures: MS AC 534, MA AE 90, MP 322 Ticket Number: 3156 Contractor: Bateman-Hall Supplier: Walters Mix Number: W172F 350 Date: 1/25/2023 Cylinder Log #: 33 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 5.9 Entrained Air Spec. (%): Concrete Temperature (°F): 59 Ambient Temperature (°F): 13 Unit Weight (PCF): 138.8 Tested By: E. Vail Date: 1/25/2023 Picked Up By: E. Vail Date: 1/26/2023 Time: 10:00 AM Max, Min Temperature 80, 69 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/1/2023 4.000 12.56 44,750.0 3563 3,500.0 Type 2 Date: 02/01/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB02032023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 800297DE-D928-413A-84CC-3617DF408CFE 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Southern foundation wall Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 3005 Contractor: BL Construction Supplier: Walters Mix Number: W-170FI U Date: 1/6/2023 Cylinder Log #: 3 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.2 Entrained Air Spec. (%): Concrete Temperature (°F): 51 Ambient Temperature (°F): 35 Unit Weight (PCF): 145.9 Tested By: M.Mansfield Date: 1/6/2023 Picked Up By: M.Mansfield Date: 1/7/2023 Time: 9:00 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/13/2023 12.56 42365 3373 3,500.00 Type 2 File name: 22247SB02032023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 800297DE-D928-413A-84CC-3617DF408CFE 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 2/3/2023 4.000 12.56 58,980.0 4696 3,500.0 Type 2 C 28 2/3/2023 4.000 12.56 57,185.0 4553 3,500.0 Type 2 D 28 2/3/2023 4.000 12.56 58,015.0 4619 3,500.0 Type 2 Second Break Average: 4623 Date: 02/07/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB02032023KD PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F9203C37-B125-48CD-A883-2B5FE67B4A1D 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 55.0 Project Name: U-Haul Moving and Storage Test Location: Southern foundation walls Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 3009 Contractor: BL Construction Supplier: Walters Mix Number: W-170FI U Date: 1/6/2023 Cylinder Log #: 4 Field Test Results: Set #: 2 Slump Maximum (in): Entrained Air (%): 1.5 Entrained Air Spec. (%): Concrete Temperature (°F): 58 Ambient Temperature (°F): 35 Unit Weight (PCF): 145.4 Tested By: M.Mansfield Date: 1/6/2023 Picked Up By: M.Mansfield Date: 1/7/2023 Time: 9:00 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/13/2023 12.56 38020 3027 3,500.00 Type 1 File name: 22247SB02032023KD PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F9203C37-B125-48CD-A883-2B5FE67B4A1D 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 2/3/2023 4.000 12.56 51,045.0 4064 3,500.0 Type 4 C 28 2/3/2023 4.000 12.56 50,550.0 4025 3,500.0 Type 2 D 28 2/3/2023 4.000 12.56 50,970.0 4058 3,500.0 Type 2 Second Break Average: 4049 Date: 02/07/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB02082023LSH2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CA00B49D-2174-4B92-BF57-B6AE9E735775 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 51.5 Project Name: U-Haul Moving and Storage Test Location: Southwest corner of job Client: Bateman-Hall Admixtures: MP 355, MS AC 534 Ticket Number: 3029 Contractor: Jerome Bowen Supplier: Walters Ready mix Mix Number: W-170FI U Date: 1/11/2023 Cylinder Log #: 10 Field Test Results: Set #: 2 Slump Maximum (in): Entrained Air (%): 1.0 Entrained Air Spec. (%): Concrete Temperature (°F): 62 Ambient Temperature (°F): 34 Unit Weight (PCF): 146.9 Tested By: M.Mansfield Date: 1/11/2023 Picked Up By: E. Vail Date: 1/13/2023 Time: 11:30 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/18/2023 12.56 39605 3153 3,500.00 Type 1 File name: 22247SB02082023LSH2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CA00B49D-2174-4B92-BF57-B6AE9E735775 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 2/8/2023 4.000 12.56 49,360.0 3930 3,500.0 Type 1 C 28 2/8/2023 4.000 12.56 49,290.0 3924 3,500.0 Type 4 D 28 2/8/2023 4.000 12.56 49,425.0 3935 3,500.0 Type 2 Second Break Average: 3930 Date: 02/09/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB02082023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5B52C198-0991-4CC3-8914-BB3E6794A613 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11 Project Name: U-Haul Moving and Storage Test Location: Southwest corner of job Client: Bateman-Hall Admixtures: MP 355, MS AC 534 Ticket Number: 3022 Contractor: Jerome Bowen Supplier: Walters Ready mix Mix Number: W-170FI U Date: 1/11/2023 Cylinder Log #: 9 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.3 Entrained Air Spec. (%): Concrete Temperature (°F): 61 Ambient Temperature (°F): 37 Unit Weight (PCF): 146.3 Tested By: M.Mansfield Date: 1/11/2023 Picked Up By: E. Vail Date: 1/13/2023 Time: 11:15 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/18/2023 12.56 54000 4299 3,500.00 Type 1 File name: 22247SB02082023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5B52C198-0991-4CC3-8914-BB3E6794A613 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 2/8/2023 4.000 12.56 64,655.0 5148 3,500.0 Type 2 C 28 2/8/2023 4.000 12.56 64,965.0 5172 3,500.0 Type 2 D 28 2/8/2023 4.000 12.56 64,095.0 5103 3,500.0 Type 3 Second Break Average: 5141 Date: 02/09/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB02102023KD PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5250040F-D2E5-4F5E-9DAF-975C7A898B99 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: 60 S of NW Corner Building B Lines: A-K Client: Bateman-Hall Admixtures: Super Plasticizer, MS AC 534, MP 322 Ticket Number: 3190 Contractor: Bryan Landon Supplier: Walters Mix Number: W-170FI U Date: 2/3/2023 Cylinder Log #: 45 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 2.0 Entrained Air Spec. (%): Concrete Temperature (°F): 56 Ambient Temperature (°F): 28 Unit Weight (PCF): 142.7 Tested By: Luke Hammar Date: 2/3/2023 Picked Up By: Luke Hammar Date: 2/4/2023 Time: 7:18 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/10/2023 4.000 12.56 33,640.0 2678 3,500.0 Type 2 Date: 02/13/2023 Reviewed By: Luke Hammar Signature: File Name 22247C02142023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D9A943C3-9CC3-4AF0-BD00-BB41F230765A 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 3262 Project Name: U-Haul Moving and Storage Test Location: Building B: Footings for southern wall Client: Bateman-Hall Admixtures: MSAC 534, MP 322 Required 28 day Strength (psi): 3,500.0 Contractor: Bateman-Hall Supplier: Walters ready mix Mix Number: W-17OFI U Date: 02/14/2023 Start Time 10:00 AM End Time 01:15 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 11:30 AM 3262 Building B: Footings for southern wall 25 146.3 1.5 N/A 60 8 Max Observations/Remarks: I arrived at the job site and looked over the rebar as well as the forms. The spacing was correct and so was the ground clearance. Once my inspection was completed, I returned to my vehicle to setup my equipment. I then waited for the truck to show up. The truck arrived around 11:15 AM and I was able to grab the batch ticket. After waiting for the driver to offload about a yard and a half, I was able to grab a sample and begin testing. I tested both air and slump, both of which were within spec. I reported to both the driver and the foreman. I then casted strength specimens. Once completed, I placed them and began my cleanup. File Name 22247C02142023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D9A943C3-9CC3-4AF0-BD00-BB41F230765A 2 I observed the remainder of the pour and returned to my vehicle to fill out my report. Tested By: M.Mansfield Signature: Reviewed By: Luke Hammar Signature: Date: 02/15/2023 Inspection Images File name: 22247SB02162023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 05C56B76-C06C-4B98-A90E-39AB0BBE1D1D 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 33 Project Name: U-Haul Moving and Storage Test Location: Building B footings, 40' north of SE corner. Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 3084 Contractor: Bateman-Hall Supplier: Walters Mix Number: W-170FI U Date: 1/19/2023 Cylinder Log #: 20 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.2 Entrained Air Spec. (%): Concrete Temperature (°F): 56 Ambient Temperature (°F): 23 Unit Weight (PCF): 141.4 Tested By: E. Vail Date: 1/19/2023 Picked Up By: Luke Hammar Date: 1/20/2023 Time: 10:01 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/26/2023 12.56 31765 2529 3,500.00 Type 2 File name: 22247SB02162023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 05C56B76-C06C-4B98-A90E-39AB0BBE1D1D 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 2/16/2023 4.000 12.56 47,730.0 3800 3,500.0 Type 1 C 28 2/16/2023 4.000 12.56 48,985.0 3900 3,500.0 Type 3 D 28 2/16/2023 4.000 12.56 51,810.0 4125 3,500.0 Type 2 Second Break Average: 3942 Date: 02/16/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB02162023LSH2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 756CC2DF-9653-4606-88E5-3B6EF0232D9D 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 66 Project Name: U-Haul Moving and Storage Test Location: Building B footings, 10' south of NE corner. Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 3088 Contractor: Bateman-Hall Supplier: Walters Mix Number: W-170FI U Date: 1/19/2023 Cylinder Log #: 21 Field Test Results: Set #: 2 Slump Maximum (in): Entrained Air (%): 1.1 Entrained Air Spec. (%): Concrete Temperature (°F): 51 Ambient Temperature (°F): 23 Unit Weight (PCF): 140.2 Tested By: E. Vail Date: 1/19/2023 Picked Up By: Luke Hammar Date: 1/20/2023 Time: 10:11 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 1/26/2023 12.56 32425 2582 3,500.00 Type 2 File name: 22247SB02162023LSH2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 756CC2DF-9653-4606-88E5-3B6EF0232D9D 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 2/16/2023 4.000 12.56 48,135.0 3832 3,500.0 Type 2 C 28 2/16/2023 4.000 12.56 46,925.0 3736 3,500.0 Type 2 D 28 2/16/2023 4.000 12.56 48,025.0 3824 3,500.0 Type 2 Second Break Average: 3797 Date: 02/16/2023 Reviewed By: Luke Hammar Signature: File Name 22247C02162023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F7DB1F5D-279C-43FB-AFB3-0BCD709A5FA2 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 3278 Project Name: U-Haul Moving and Storage Test Location: Building B, southern wall. Client: Bateman-Hall Admixtures: MA AE 90, MP 322 Required 28 day Strength (psi): 3,500.0 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: W172F 350 Date: 02/16/2023 Start Time 10:30 AM End Time 01:15 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 11:30 AM 3278 Building B, southern wall. 13 139.5 5.5 6 +- 1.5 65 8 Max Observations/Remarks: I arrived on site at 10:45 am and checked in with the Bryan Landon Construction foreman about where the best place to set up would be that was out of the way. After setting up my gear I went over to the wall forms to look over the rebar. I checked for correct size, spacing, and to make sure no rebar was touching the forms. All appeared to be in good order. Once the concrete arrived I was able to obtain a sample for testing. I tested for air, temp, and slump. All results were within spec and reported to Walters and Bryan Landon Construction. After testing, I made strength cylinders and then cleaned up my gear. Upon completion I was able to observe the remainder of the pour. I did notice that mechanical vibration was being utilized to consolidate the concrete. I left location at 12:45 pm. File Name 22247C02162023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F7DB1F5D-279C-43FB-AFB3-0BCD709A5FA2 2 Tested By: E. Vail Signature: Reviewed By: Luke Hammar Signature: Date: 02/16/2023 Inspection Images File Name 22247C02172023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 360110FA-6F59-4EF7-BBB1-D2CE5568B399 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 7.5 Ticket #: 3285 Project Name: U-Haul Moving and Storage Test Location: Building B, south eastern most wall. Client: Bateman-Hall Admixtures: MA AE 90, MP 322 Required 28 day Strength (psi): 3,500.0 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: W172F 350 Date: 02/17/2023 Start Time 11:00 AM End Time 01:15 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 11:45 AM 3285 Building B, south eastern most wall. 14 138.2 6.8 6 +- 1.5 59 8 Max Observations/Remarks: I arrived on site at 11:15 am and checked in with the Bryan Landon Construction foreman about where the best place to set up would be that was out of the way. After setting up my gear I went over to the wall forms to look over the rebar. I checked for correct size, spacing, and to make sure no rebar was touching the forms. All appeared to be in good order. Once the concrete arrived I was able to obtain a sample for testing. I tested for air, temp, and slump. All results were within spec and reported to Walters and Bryan Landon Construction. After testing, I made strength cylinders and then cleaned up my gear. Upon completion I was able to observe the remainder of the pour. I did notice that mechanical vibration was being utilized to consolidate the concrete. I left location at 1:00 pm. File Name 22247C02172023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 360110FA-6F59-4EF7-BBB1-D2CE5568B399 2 Tested By: E. Vail Signature: Reviewed By: Luke Hammar Signature: Date: 02/20/2023 Inspection Images File name: 22247FB02212023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9DA249E0-ECB4-417A-8E15-E085959682B7 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Building B: Footings for southern wall Client: Bateman-Hall Admixtures: MSAC 534, MP 322 Ticket Number: 3262 Contractor: Bryan Landon Supplier: Walters ready mix Mix Number: W-17OFI U Date: 2/14/2023 Cylinder Log #: 56 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 1.5 Entrained Air Spec. (%): Concrete Temperature (°F): 60 Ambient Temperature (°F): 25 Unit Weight (PCF): 146.3 Tested By: M.Mansfield Date: 2/14/2023 Picked Up By: Luke Hammar Date: 2/15/2023 Time: 9:22 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/21/2023 4.000 12.56 54,165.0 4313 3,500.0 Type 2 Date: 02/22/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB02222023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E2E98429-CCD0-4CE5-870F-D27EE406DEC2 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11 Project Name: U-Haul Moving and Storage Test Location: Building D foundation wall. 15 north of SE corner of building. Client: Bateman-Hall Admixtures: MS AC 534, MA AE 90, MP 322 Ticket Number: 3156 Contractor: Bateman-Hall Supplier: Walters Mix Number: W172F 350 Date: 1/25/2023 Cylinder Log #: 33 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 5.9 Entrained Air Spec. (%): Concrete Temperature (°F): 59 Ambient Temperature (°F): 13 Unit Weight (PCF): 138.8 Tested By: E. Vail Date: 1/25/2023 Picked Up By: E. Vail Date: 1/26/2023 Time: 10:00 AM Max, Min Temperature 80, 69 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/1/2023 12.56 44750 3563 3,500.00 Type 2 File name: 22247SB02222023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E2E98429-CCD0-4CE5-870F-D27EE406DEC2 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 2/22/2023 4.000 12.56 58,780.0 4680 3,500.0 Type 2 C 28 2/22/2023 4.000 12.56 54,765.0 4360 3,500.0 Type 2 D 28 2/22/2023 4.000 12.56 55,985.0 4457 3,500.0 Type 4 Second Break Average: 4499 Date: 02/22/2023 Reviewed By: Luke Hammar Signature: File Name 22247C02212023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9425151A-E9F9-475C-8EE6-484988A0CA09 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Ticket #: 03308 Project Name: U-Haul Moving and Storage Test Location: East of building B Client: Bateman-Hall Admixtures: MS AC534, MP 322 Required 28 day Strength (psi): 3,500.0 Contractor: Bryan Landon Supplier: Walters Mix Number: W-170FI U Date: 02/21/2023 Start Time 10:45 AM End Time 01:00 PM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 12:15 PM 03308 East of building B 37 146.9 1.5 N/A 62 8 Max Observations/Remarks: I arrived at the job and spoke with the foreman. We discussed the pour and I went and performed a rebar inspection. Once completed I returned to my vehicle to setup my equipment. After setting up I returned to the pour site and waited for the truck to arrive. The truck arrived just after 12, and I was able to grab my ticket. After waiting the proper amount of time I grabbed a sample and began testing. I tested both air and slump, and found them to be within spec. I reported the results to the driver and the foreman. I observed the remainder of the pour. Once completed I returned to fill out my report. Tested By: M.Mansfield Signature: Reviewed By: Luke Hammar Signature: File Name 22247C02212023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9425151A-E9F9-475C-8EE6-484988A0CA09 2 Date: 02/23/2023 Inspection Images File name: 22247FB03032023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 70CEF8B1-031E-467F-BF6A-EB3A391444B9 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 8.8 Project Name: U-Haul Moving and Storage Test Location: Loading dock foundation walls Client: Bateman-Hall Admixtures: X-Seed, MS AC 534, MP 322 Ticket Number: 3333 Contractor: Bryan Landon Supplier: Walters ready mix Mix Number: W172F 350 Date: 2/24/2023 Cylinder Log #: 73 Field Test Results: Set #: 1 Entrained Air (%): 7.5 Concrete Temperature (°F): 58 Ambient Temperature (°F): 27 Unit Weight (PCF): 137.8 Tested By: M.Mansfield Date: 2/24/2023 Picked Up By: K. Drake Date: 2/25/2023 Time: 11:44 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 3/3/2023 4.000 12.56 48,735.0 3880 3,500.0 Type 2 Date: 03/03/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB02232023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 18D89B9E-943F-47C1-B20C-45EC7EC8D538 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Building B, south eastern most wall. Client: Bateman-Hall Admixtures: MA AE 90, MP 322 Ticket Number: 3278 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: W172F 350 Date: 2/16/2023 Cylinder Log #: 59 Field Test Results: Set #: 1 Slump Maximum (in): Entrained Air (%): 5.5 Entrained Air Spec. (%): Concrete Temperature (°F): 65 Ambient Temperature (°F): 13 Unit Weight (PCF): 139.5 Tested By: E. Vail Date: 2/16/2023 Picked Up By: E. Vail Date: 2/17/2023 Time: 1:45 PM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/23/2023 4.000 12.56 60,345.0 4805 3,500.0 Type 1 Date: 02/24/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB03142023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F6D29BD9-683E-4EAD-A4AE-D04B43761897 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11.0 Project Name: U-Haul Moving and Storage Test Location: Building B: Footings for southern wall Client: Bateman-Hall Admixtures: MSAC 534, MP 322 Contractor: Bryan Landon Supplier: Walters ready mix Mix Number: W-17OFI U Date: 2/14/2023 Cylinder Log #: 56 Field Test Results: Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 60 Ambient Temperature (°F): 25 Unit Weight (PCF): 146.3 Tested By: M.Mansfield Date: 2/14/2023 Picked Up By: Luke Hammar Date: 2/15/2023 Time: 9:22 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/21/2023 12.56 54165 4313 3,500.00 Type 2 File name: 22247SB03142023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F6D29BD9-683E-4EAD-A4AE-D04B43761897 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 3/14/2023 4.000 12.56 65,130.0 5186 3,500.0 Type 2 C 28 3/14/2023 4.000 12.56 65,185.0 5190 3,500.0 Type 3 D 28 3/14/2023 4.000 12.56 67,305.0 5359 3,500.0 Type 1 Second Break Average: 5245 Date: 03/14/2023 Reviewed By: Luke Hammar Signature: File name: 22247CB03172023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9ACAAACF-711F-4BFE-B0B6-5C398F1ECAAB 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 7.5 Project Name: U-Haul Moving and Storage Test Location: Building B, south eastern most wall. Client: Bateman-Hall Admixtures: MA AE 90, MP 322 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: W172F 350 Date: 2/17/2023 Cylinder Log #: 61 Field Test Results: Set #: 1 Entrained Air (%): 6.8 Concrete Temperature (°F): 59 Ambient Temperature (°F): 14 Unit Weight (PCF): 138.2 Tested By: E. Vail Date: 2/17/2023 Picked Up By: Luke Hammar Date: 2/18/2023 Time: 11:03 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/24/2023 12.57 42395 3373 3,500.00 Type 2 File name: 22247CB03172023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9ACAAACF-711F-4BFE-B0B6-5C398F1ECAAB 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 3/17/2023 4.000 12.57 55,745.0 4435 3,500.0 Type 2 C 28 3/17/2023 4.000 12.57 55,705.0 4432 3,500.0 Type 2 D 28 3/17/2023 4.000 12.57 55,290.0 4399 3,500.0 Type 2 Second Break Average: 4422 Date: 03/20/2023 Reviewed By: Luke Hammar Signature: File name: 22247CB03162023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8296565D-5A89-4B4A-8B25-1CF7712F80AE 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11 Project Name: U-Haul Moving and Storage Test Location: Building B, south eastern most wall. Client: Bateman-Hall Admixtures: MA AE 90, MP 322 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: W172F 350 Date: 2/16/2023 Cylinder Log #: 59 Field Test Results: Set #: 1 Entrained Air (%): 5.5 Concrete Temperature (°F): 65 Ambient Temperature (°F): 13 Unit Weight (PCF): 139.5 Tested By: E. Vail Date: 2/16/2023 Picked Up By: E. Vail Date: 2/17/2023 Time: 1:45 PM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/23/2023 12.57 60345 4801 3,500.00 Type 1 File name: 22247CB03162023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8296565D-5A89-4B4A-8B25-1CF7712F80AE 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 3/16/2023 4.000 12.57 68,545.0 5453 3,500.0 Type 2 C 28 3/16/2023 4.000 12.57 67,930.0 5404 3,500.0 Type 2 D 28 3/16/2023 4.000 12.57 70,245.0 5588 3,500.0 Type 2 Second Break Average: 5482 Date: 03/20/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB03242023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 859E450C-D5F6-4E26-9F14-FA72828E29E7 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 8.8 Project Name: U-Haul Moving and Storage Test Location: Loading dock foundation walls Client: Bateman-Hall Admixtures: X-Seed, MS AC 534, MP 322 Contractor: Bryan Landon Supplier: Walters ready mix Mix Number: W172F 350 Date: 2/24/2023 Cylinder Log #: 73 Field Test Results: Set #: 1 Entrained Air (%): 7.5 Concrete Temperature (°F): 58 Ambient Temperature (°F): 27 Unit Weight (PCF): 137.8 Tested By: M.Mansfield Date: 2/24/2023 Picked Up By: K. Drake Date: 2/25/2023 Time: 11:44 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 3/3/2023 12.57 48735 3877 3,500.00 Type 2 File name: 22247SB03242023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 859E450C-D5F6-4E26-9F14-FA72828E29E7 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 3/24/2023 4.000 12.57 62,030.0 4935 3,500.0 Type 4 C 28 3/24/2023 4.000 12.57 64,670.0 5145 3,500.0 Type 2 D 28 3/24/2023 4.000 12.57 63,275.0 5034 3,500.0 Type 2 Second Break Average: 5038 Date: 03/24/2023 Reviewed By: Luke Hammar Signature: File name: 22247CFB04172023 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 3B21445A-02B8-4270-9E7F-25A2E2E88A2C 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 3.5 Project Name: U-Haul Moving and Storage Test Location: K Line: 3-4 Client: Bateman-Hall Admixtures: MA AE 90, MP 322 Ticket Number: 3645 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: W172F 350 Date: 4/10/2023 Cylinder Log #: 125 Field Test Results: Set #: 1 Entrained Air (%): 6.6 Concrete Temperature (°F): 68 Ambient Temperature (°F): 61 Unit Weight (PCF): 139.0 Tested By: E. Vail Date: 4/10/2023 Picked Up By: E. Vail Date: 4/11/2023 Time: 4:15 PM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 4/17/2023 4.000 12.56 45,555.0 3627 3,500.0 Type 1 Date: 04/17/2023 Reviewed By: Luke Hammar Signature: File Name 22247C04282023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A9C15922-AEC2-4AA2-BC20-2218FB5D2B3E 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Ticket #: 04042 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Required 28 day Strength (psi): 4,000.0 Contractor: Bryan Landon Supplier: Walter’s Ready Mix Mix Number: W-172FI U Date: 04/28/2023 Start Time 04:57 AM End Time 11:00 AM Current Weather Conditions: Sunny/Clear Wind: Calm Testing: Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 10.0 04:50 AM Building A slab 27 36.100 145.0 69 1.5 N/A 7 6 Max 2 50.0 05:25 AM Building A slab 28 36.000 144.6 68 1.0 N/A 7 6 Max 3 110.0 06:00 AM Building A slab 28 36.240 145.5 67 1.5 N/A 7 6 Max 4 150.0 06:20 AM Building A slab 28 36.100 145.0 67 1.5 N/A 7 6 Max 5 200.0 06:50 AM Building A slab 29 36.300 145.8 66 1.5 N/A 7 6 Max 6 250.0 07:35 AM Building A slab 30 36.240 145.5 65 1.5 N/A 7 6 Max 7 300.0 08:10 AM Building A slab 33 36.400 146.2 64 1.6 N/A 5.5 6 Max 8 350.0 08:35 AM Building A 36 36.240 145.5 65 1.7 N/A 5 6 Max File Name 22247C04282023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A9C15922-AEC2-4AA2-BC20-2218FB5D2B3E 2 Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): slab 9 410.0 09:15 AM Building A slab 40 36.300 145.8 68 1.5 N/A 5 6 Max 10 450.0 09:40 AM Building A slab 41 36.260 145.6 67 1.6 N/A 5 6 Max 11 500.0 10:10 AM Building A slab 41 36.300 145.8 67 1.6 N/A 5 6 Max Observations/Remarks: I arrived on site at 4:30 AM, contractor was on site setting up their equipment. I walked around checking on the forms to make sure the rebar was within spec. The first truck arrived around 4:50-5:00 AM. We grabbed our first sample around 5:10 AM. We tested every 50-60 yards of the pour, and did a total of 11 tests. We finished testing and started to clean up around 10:15-10:20 am. Tested By: B. Choffin Signature: Reviewed By: Luke Hammar Signature: Date: 04/28/2023 Inspection Images File Name 22247C04282023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A9C15922-AEC2-4AA2-BC20-2218FB5D2B3E 3 File Name 22247C05032023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1CCDC3A3-16F7-4071-99F1-1859289FF501 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 20.0 Ticket #: 04198 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Na Required 28 day Strength (psi): 4,000.0 Contractor: Bryan Landon Supplier: Walter’s Ready Mix Mix Number: N-172F1 U Date: 05/03/2023 Start Time 04:30 AM End Time 09:45 AM Current Weather Conditions: Partly Cloudy Wind: Calm Testing: Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 20.0 05:20 AM Building A slab 39 36.460 146.4 74 1.5 N/A 7 6 Max 2 60.0 05:40 AM Building A slab 39 36.520 146.7 70 1.7 N/A 7 6 Max 3 110.0 06:30 AM Building A slab 40 36.400 146.2 69 1.6 N/A 6.5 6 Max 4 160.0 06:45 AM Building A slab 41 36.400 146.2 68 1.7 N/A 6.5 6 Max 5 210.0 07:10 AM Building A slab 44 36.400 146.2 71 1.9 N/A 5.5 6 Max 6 260.0 07:55 AM Building A slab 47 36.500 146.6 72 1.8 N/A 6 6 Max 7 310.0 08:40 AM Building A slab 53 36.280 145.7 73 1.8 N/A 5.5 6 Max File Name 22247C05032023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1CCDC3A3-16F7-4071-99F1-1859289FF501 2 Observations/Remarks: I arrived on site around 4:30 am. I got out of my vehicle to go inspect the rebar placements and found it to be within general conformance to project guidelines. I then proceeded to set up my testing equipment for the day. The first truck arrived around 5 am. I got my first sample around 5:10-5:15 AM. All tests resulted to be within spec. And were reported. I did a total of 7 tests. I observed the duration of the pour and wrote this report. Tested By: B. Choffin Signature: Reviewed By: Luke Hammar Signature: Date: 05/03/2023 Inspection Images File Name 22247C05032023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 1CCDC3A3-16F7-4071-99F1-1859289FF501 3 File name: 22247FB05052023LSH9 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C91B1FB1-8919-435D-87D4-561828391395 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 410 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Ticket Number: 4084 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 161 Field Test Results: Set #: 9 Entrained Air (%): 1.5 Concrete Temperature (°F): 68 Ambient Temperature (°F): 40 Unit Weight (PCF): 145.8 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 12:40 PM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 4.000 12.56 52,450.0 4176 4,000.0 Type 2 Date: 05/05/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05052023LSH8 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. ED74B6DB-6739-496E-A56B-8EE5414F53B9 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 350 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Ticket Number: 4078 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 160 Field Test Results: Set #: 8 Entrained Air (%): 1.7 Concrete Temperature (°F): 65 Ambient Temperature (°F): 36 Unit Weight (PCF): 145.5 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 12:34 PM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 4.000 12.56 52,130.0 4150 4,000.0 Type 2 Date: 05/05/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05052023LSH7 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 6D172B57-1C94-4A29-BCD0-012AAE37616B 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 300 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Ticket Number: 4073 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 159 Field Test Results: Set #: 7 Entrained Air (%): 1.6 Concrete Temperature (°F): 64 Ambient Temperature (°F): 33 Unit Weight (PCF): 146.2 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 12:27 PM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 4.000 12.56 56,270.0 4480 4,000.0 Type 2 Date: 05/05/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05052023LSH6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 08737B9C-EEB0-4256-BA86-90DA5869214A 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 250 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Ticket Number: 4066 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 158 Field Test Results: Set #: 6 Entrained Air (%): 1.5 Concrete Temperature (°F): 65 Ambient Temperature (°F): 30 Unit Weight (PCF): 145.5 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 12:21 PM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 4.000 12.56 52,655.0 4192 4,000.0 Type 3 Date: 05/05/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05052023LSH1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A9486F6F-9AFC-4D18-A926-B760B1AC5395 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Ticket Number: 4042 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 153 Field Test Results: Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 69 Ambient Temperature (°F): 27 Unit Weight (PCF): 145 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 11:42 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 4.000 12.56 54,250.0 4319 4,000.0 Type 1 Date: 05/05/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB05082023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 386EEC4D-3859-45F3-9182-F57612FD8002 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 3.5 Project Name: U-Haul Moving and Storage Test Location: K Line: 3-4 Client: Bateman-Hall Admixtures: MA AE 90, MP 322 Contractor: Bryan Landon Construction Supplier: Walters Mix Number: W172F 350 Date: 4/10/2023 Cylinder Log #: 125 Field Test Results: Set #: 1 Entrained Air (%): 6.6 Concrete Temperature (°F): 68 Ambient Temperature (°F): 61 Unit Weight (PCF): 139 Tested By: E. Vail Date: 4/10/2023 Picked Up By: E. Vail Date: 4/11/2023 Time: 4:15 PM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 4/17/2023 12.57 45555 3624 3,500.00 Type 1 File name: 22247SB05082023EV PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 386EEC4D-3859-45F3-9182-F57612FD8002 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/8/2023 4.000 12.57 59,005.0 4694 3,500.0 Type 2 C 28 5/8/2023 4.000 12.57 59,220.0 4711 3,500.0 Type 4 D 28 5/8/2023 4.000 12.57 59,950.0 4769 3,500.0 Type 2 Second Break Average: 4725 Date: 05/08/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05102023LSH6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 80C3D6F8-2F21-4675-8163-F68D4DD817C9 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 260 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Ticket Number: 4223 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 175 Field Test Results: Set #: 6 Entrained Air (%): 1.8 Concrete Temperature (°F): 72 Ambient Temperature (°F): 47 Unit Weight (PCF): 146.6 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 10:57 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 4.000 12.56 67,390.0 5365 4,000.0 Type 1 Date: 05/10/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05102023LSH5 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8A6A3732-F228-442C-B116-58F09BAFAF9C 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 210 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Ticket Number: 4217 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 174 Field Test Results: Set #: 5 Entrained Air (%): 1.9 Concrete Temperature (°F): 71 Ambient Temperature (°F): 44 Unit Weight (PCF): 146.2 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 10:49 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 4.000 12.56 66,925.0 5328 4,000.0 Type 2 Date: 05/10/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05102023LSH4 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. FED5F648-4992-4860-8788-E0C175BEB6AE 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 160 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Ticket Number: 4212 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 173 Field Test Results: Set #: 4 Entrained Air (%): 1.7 Concrete Temperature (°F): 68 Ambient Temperature (°F): 41 Unit Weight (PCF): 146.2 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 11:17 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 4.000 12.56 62,890.0 5007 4,000.0 Type 4 Date: 05/10/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05102023LSH3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8FD12EEC-167D-4F01-875B-B049B113E9B4 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 110 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Ticket Number: 4207 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 172 Field Test Results: Set #: 3 Entrained Air (%): 1.6 Concrete Temperature (°F): 69 Ambient Temperature (°F): 40 Unit Weight (PCF): 146.2 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 11:25 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 4.000 12.56 57,805.0 4602 4,000.0 Type 3 Date: 05/10/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05102023LSH2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 434DEA5C-6BAD-4A9C-AA15-20A295D14516 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 60 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Ticket Number: 4202 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 171 Field Test Results: Set #: 2 Entrained Air (%): 1.7 Concrete Temperature (°F): 70 Ambient Temperature (°F): 39 Unit Weight (PCF): 146.7 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 11:32 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 4.000 12.56 58,215.0 4635 4,000.0 Type 2 Date: 05/10/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05102023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 305EEA74-9DF0-4DE4-8EFA-3CFB6557C839 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 20 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Ticket Number: 4198 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 170 Field Test Results: Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 74 Ambient Temperature (°F): 39 Unit Weight (PCF): 146.4 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 11:40 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 4.000 12.56 60,580.0 4823 4,000.0 Type 1 Date: 05/10/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB05102023CH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. D7656983-9903-4B9C-A05F-E1ABF73C75B0 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 310.0 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Ticket Number: 4228 Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 176 Field Test Results: Set #: 7 Entrained Air (%): 1.8 Concrete Temperature (°F): 73 Ambient Temperature (°F): 53 Unit Weight (PCF): 145.7 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 11:08 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 4.000 12.56 53,725.0 4277 4,000.0 Type 6 Date: 05/10/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB03032023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 91C5EB5B-27A8-4D00-874B-8FD7FCA39278 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 11 Project Name: U-Haul Moving and Storage Test Location: 60 S of NW Corner Building B Lines: A-K Client: Bateman-Hall Admixtures: Super Plasticizer, MS AC 534, MP 322 Contractor: Bryan Landon Supplier: Walters Mix Number: W-170FI U Date: 2/3/2023 Cylinder Log #: 45 Field Test Results: Set #: 1 Entrained Air (%): 2.0 Concrete Temperature (°F): 56 Ambient Temperature (°F): 28 Unit Weight (PCF): 142.7 Tested By: Luke Hammar Date: 2/3/2023 Picked Up By: Luke Hammar Date: 2/4/2023 Time: 7:18 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 2/10/2023 12.56 33640 2678 3,500.00 Type 2 File name: 22247SB03032023LSH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 91C5EB5B-27A8-4D00-874B-8FD7FCA39278 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 3/3/2023 4.000 12.56 47,115.0 3751 3,500.0 Type 1 C 28 3/3/2023 4.000 12.56 47,720.0 3799 3,500.0 Type 2 D 28 3/3/2023 4.000 12.56 48,330.0 3848 3,500.0 Type 3 Second Break Average: 3799 Date: 03/03/2023 Reviewed By: Luke Hammar Signature: File Name 22247C02242023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C5A02814-5AAC-4AA6-9828-03428D2B9896 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 8.8 Ticket #: 3333 Project Name: U-Haul Moving and Storage Test Location: Loading dock foundation walls Client: Bateman-Hall Admixtures: X-Seed, MS AC 534, MP 322 Required 28 day Strength (psi): 3,500.0 Contractor: Bateman-Hall Supplier: Walters ready mix Mix Number: W172F 350 Date: 02/24/2023 Start Time 09:00 AM End Time 11:00 AM Testing: Set #:Time Tested: Ticket #:Test Location: Ambient Temp. (°F): Unit Weight (PCF): Entrained Air (%): Entrained Air Spec. (%): Concrete Temp. (°F): Slump (in): Slump Spec. (in): 1 10:30 AM 3333 Loading dock foundation walls 27 137.8 7.5 6 +- 1.5 58 8 Max Observations/Remarks: I arrived at the job site around 9:15 and looked over the rebar. It looked good for the most part, I spoke with the crew about some question areas. And the crew solved the issues. I returned to my vehicle to setup my equipment. The first truck arrived around 10:20, I was able to grab a ticket and wait to grab a sample. Once I received a sample, I returned to my work area to begin my testing. I tested both air and slump, both of which were within spec. I reported the results to the driver. I cleaned my equipment and left the job site. Tested By: M.Mansfield Reviewed By: Luke Hammar File Name 22247C02242023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C5A02814-5AAC-4AA6-9828-03428D2B9896 2 Signature:Signature: Date: 02/27/2023 Inspection Images File Name 22247C02242023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C5A02814-5AAC-4AA6-9828-03428D2B9896 3 File name: 22247SB05262023EV1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F38127B3-EFD0-4250-9417-CF54B0F3BE9F 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 350 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 160 Field Test Results: Set #: 8 Entrained Air (%): 1.7 Concrete Temperature (°F): 65 Ambient Temperature (°F): 36 Unit Weight (PCF): 145.5 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 12:34 PM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 12.56 52130 4150 4,000.00 Type 2 File name: 22247SB05262023EV1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F38127B3-EFD0-4250-9417-CF54B0F3BE9F 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/26/2023 4.000 12.56 65,875.0 5245 4,000.0 Type 2 C 28 5/26/2023 4.000 12.56 66,450.0 5291 4,000.0 Type 1 D 28 5/26/2023 4.000 12.56 64,310.0 5120 4,000.0 Type 1 Second Break Average: 5219 Date: 05/26/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB05262023EV2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CC453F13-38DA-4B46-B963-1FF9FF776CBA 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 410 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 161 Field Test Results: Set #: 9 Entrained Air (%): 1.5 Concrete Temperature (°F): 68 Ambient Temperature (°F): 40 Unit Weight (PCF): 145.8 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 12:40 PM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 12.56 52450 4176 4,000.00 Type 2 File name: 22247SB05262023EV2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CC453F13-38DA-4B46-B963-1FF9FF776CBA 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/26/2023 4.000 12.56 66,865.0 5324 4,000.0 Type 1 C 28 5/26/2023 4.000 12.56 68,350.0 5442 4,000.0 Type 3 D 28 5/26/2023 4.000 12.56 67,030.0 5337 4,000.0 Type 2 Second Break Average: 5368 Date: 05/26/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB05262023EV4 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8336D13C-7D34-4AEC-AF91-4361130E2262 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 500 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 163 Field Test Results: Set #: 11 Entrained Air (%): 1.6 Concrete Temperature (°F): 67 Ambient Temperature (°F): 41 Unit Weight (PCF): 145.8 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 12:54 PM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 12.56 54590 4346 4,000.00 Type 2 File name: 22247SB05262023EV4 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8336D13C-7D34-4AEC-AF91-4361130E2262 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/26/2023 4.000 12.56 70,935.0 5648 4,000.0 Type 2 C 28 5/26/2023 4.000 12.56 74,125.0 5902 4,000.0 Type 1 D 28 5/26/2023 4.000 12.56 72,840.0 5799 4,000.0 Type 5 Second Break Average: 5783 Date: 05/26/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB05262023EV5 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CE0A5251-4986-40B3-81B0-B4E28F4D585A 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 250 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 158 Field Test Results: Set #: 6 Entrained Air (%): 1.5 Concrete Temperature (°F): 65 Ambient Temperature (°F): 30 Unit Weight (PCF): 145.5 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 12:21 PM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 12.56 52655 4192 4,000.00 Type 3 File name: 22247SB05262023EV5 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CE0A5251-4986-40B3-81B0-B4E28F4D585A 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/26/2023 4.000 12.56 68,230.0 5432 4,000.0 Type 6 C 28 5/26/2023 4.000 12.56 66,590.0 5302 4,000.0 Type 2 D 28 5/26/2023 4.000 12.56 67,960.0 5411 4,000.0 Type 1 Second Break Average: 5382 Date: 05/26/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB05262023EV6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 659E5B4C-D554-45E7-9FF2-0421A4B0CD14 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 200 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 157 Field Test Results: Set #: 5 Entrained Air (%): 1.5 Concrete Temperature (°F): 66 Ambient Temperature (°F): 29 Unit Weight (PCF): 145.8 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 12:15 PM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 12.56 51345 4088 4,000.00 Type 2 File name: 22247SB05262023EV6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 659E5B4C-D554-45E7-9FF2-0421A4B0CD14 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/26/2023 4.000 12.56 68,105.0 5422 4,000.0 Type 2 C 28 5/26/2023 4.000 12.56 68,640.0 5465 4,000.0 Type 1 D 28 5/26/2023 4.000 12.56 68,605.0 5462 4,000.0 Type 2 Second Break Average: 5450 Date: 05/26/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB05262023EV10 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 730D48A1-705A-43E1-8A72-7706B5D7AF65 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 153 Field Test Results: Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 69 Ambient Temperature (°F): 27 Unit Weight (PCF): 145 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 11:42 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 12.56 54250 4319 4,000.00 Type 1 File name: 22247SB05262023EV10 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 730D48A1-705A-43E1-8A72-7706B5D7AF65 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/26/2023 4.000 12.56 73,050.0 5816 4,000.0 Type 4 C 28 5/26/2023 4.000 12.56 70,110.0 5582 4,000.0 Type 1 D 28 5/26/2023 4.000 12.56 68,080.0 5420 4,000.0 Type 1 Second Break Average: 5606 Date: 05/26/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB05262023EV11 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7C4B4E5B-6D92-46DD-A0DC-CA4577A7BC43 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 300 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: Super Plastisizer, 2% NC Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: W-172FI U Date: 4/28/2023 Cylinder Log #: 159 Field Test Results: Set #: 7 Entrained Air (%): 1.6 Concrete Temperature (°F): 64 Ambient Temperature (°F): 33 Unit Weight (PCF): 146.2 Tested By: B. Choffin Date: 4/28/2023 Picked Up By: Luke Hammar Date: 4/29/2023 Time: 12:27 PM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/5/2023 12.56 56270 4480 4,000.00 Type 2 File name: 22247SB05262023EV11 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7C4B4E5B-6D92-46DD-A0DC-CA4577A7BC43 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/26/2023 4.000 12.56 78,065.0 6215 4,000.0 Type 5 C 28 5/26/2023 4.000 12.56 75,970.0 6049 4,000.0 Type 1 D 28 5/26/2023 4.000 12.56 73,675.0 5866 4,000.0 Type 5 Second Break Average: 6043 Date: 05/26/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C1156B4A-7177-4B7A-A17C-0EAD4BFA1CCB 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Ticket #: 05029 Project Name: U-Haul Moving and Storage Test Location: Building A Gridline E:9 Client: Bateman-Hall Admixtures: MS AC 534, MP 322, MA AE 90 Required 28 day Strength (psi): 3,500.0 Supplier: Walters Ready Mix, Inc. Mix Number: 142-3500 Date: 05/31/2023 Start Time 04:30 AM End Time 08:45 AM Testing: Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 10.0 05:15 AM Building A Gridline E: 9 46 35.100 141.0 69 5.0 6 +- 1.5 6.5 8 Max 2 60.0 07:15 AM Building A Gridline D: 14 50 35.200 141.4 68 5.0 6 +- 1.5 7 8 Max Observations/Remarks: I arrived on site at approximately 4:55 AM and proceeded to immediately set up my testing equipment in preparation for testing. Shortly after I inspected the rebar placement inside of the forms and found them to be within acceptable specifications. When the first truck arrived on site at approximately 5:00 AM I proceeded to acquire a sample and test. The tests were acceptable and passed within the given parameters. However when testing the truck for 50-60 yards I found the air quality to be lower than passing. By the time the test was finished, the concrete had all been poured and the truck had left. I then tested the truck with 80-90 yards and found all tests to be acceptable and within the given parameters. PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C1156B4A-7177-4B7A-A17C-0EAD4BFA1CCB 2 I then cleaned my testing equipment and observed that the contractor used a mechanical vibration device to properly displace the material. I observed that an employee of the contractor stayed behind after other employees had moved on to ensure that the concrete was all finished correctly. Tested By: Michael Hammar Signature: Reviewed By: E. Vail Signature: Date: 05/31/2023 Inspection Images PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C1156B4A-7177-4B7A-A17C-0EAD4BFA1CCB 3 File name: 22247SB05312023JPC7 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 96156F20-667B-497F-891F-E7C940906EA0 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 210.0 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 174 Field Test Results: Set #: 5 Entrained Air (%): 1.9 Concrete Temperature (°F): 71 Ambient Temperature (°F): 44 Unit Weight (PCF): 146.2 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 10:49 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 12.56 66925 5328 4,000.00 Type 2 File name: 22247SB05312023JPC7 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 96156F20-667B-497F-891F-E7C940906EA0 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/31/2023 4.000 12.56 83,805.0 6672 4,000.0 Type 1 C 28 5/31/2023 4.000 12.56 77,995.0 6210 4,000.0 Type 1 D 28 5/31/2023 4.000 12.56 83,710.0 6665 4,000.0 Type 1 Second Break Average: 6515 Date: 05/31/2023 Reviewed By: E. Vail Signature: File name: 22247SB05312023JPC6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 12A771D7-BD4C-43C4-9E01-03C5B84A39D9 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 260.0 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 175 Field Test Results: Set #: 6 Entrained Air (%): 1.8 Concrete Temperature (°F): 72 Ambient Temperature (°F): 47 Unit Weight (PCF): 146.6 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 10:57 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 12.56 67390 5365 4,000.00 Type 1 File name: 22247SB05312023JPC6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 12A771D7-BD4C-43C4-9E01-03C5B84A39D9 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/31/2023 4.000 12.56 85,680.0 6822 4,000.0 Type 1 C 28 5/31/2023 4.000 12.56 82,425.0 6563 4,000.0 Type 1 D 28 5/31/2023 4.000 12.56 85,920.0 6841 4,000.0 Type 1 Second Break Average: 6742 Date: 05/31/2023 Reviewed By: E. Vail Signature: File name: 22247SB05312023JPC5 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 2C3D4CF3-091B-4730-BA55-EDD1C4D0C39B 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 310.0 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 176 Field Test Results: Set #: 7 Entrained Air (%): 1.8 Concrete Temperature (°F): 73 Ambient Temperature (°F): 53 Unit Weight (PCF): 145.7 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 11:08 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 12.56 53725 4277 4,000.00 Type 6 File name: 22247SB05312023JPC5 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 2C3D4CF3-091B-4730-BA55-EDD1C4D0C39B 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/31/2023 4.000 12.56 72,305.0 5757 4,000.0 Type 1 C 28 5/31/2023 4.000 12.56 70,770.0 5635 4,000.0 Type 1 D 28 5/31/2023 4.000 12.56 68,645.0 5465 4,000.0 Type 3 Second Break Average: 5619 Date: 05/31/2023 Reviewed By: E. Vail Signature: File name: 22247SB05312023JPC3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7521C3D2-5D6D-439E-B99F-9800966E605E 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 110.0 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 172 Field Test Results: Set #: 3 Entrained Air (%): 1.6 Concrete Temperature (°F): 69 Ambient Temperature (°F): 40 Unit Weight (PCF): 146.2 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 11:25 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 12.56 57805 4602 4,000.00 Type 3 File name: 22247SB05312023JPC3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7521C3D2-5D6D-439E-B99F-9800966E605E 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/31/2023 4.000 12.56 76,825.0 6117 4,000.0 Type 3 C 28 5/31/2023 4.000 12.56 75,520.0 6013 4,000.0 Type 3 D 28 5/31/2023 4.000 12.56 73,680.0 5866 4,000.0 Type 3 Second Break Average: 5999 Date: 05/31/2023 Reviewed By: E. Vail Signature: File name: 22247SB05312023JPC2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C56EE552-F357-4CA0-8FDC-B375606E7809 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 60.0 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 171 Field Test Results: Set #: 2 Entrained Air (%): 1.7 Concrete Temperature (°F): 70 Ambient Temperature (°F): 39 Unit Weight (PCF): 146.7 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 11:32 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 12.56 58215 4635 4,000.00 Type 2 File name: 22247SB05312023JPC2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C56EE552-F357-4CA0-8FDC-B375606E7809 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/31/2023 4.000 12.56 77,840.0 6197 4,000.0 Type 1 C 28 5/31/2023 4.000 12.56 78,605.0 6258 4,000.0 Type 1 D 28 5/31/2023 4.000 12.56 77,360.0 6159 4,000.0 Type 1 Second Break Average: 6204 Date: 05/31/2023 Reviewed By: E. Vail Signature: File name: 22247SB05312023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 83D10B52-3890-4624-9EAF-E8D835DD72C3 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 20.0 Project Name: U-Haul Moving and Storage Test Location: Building A slab Client: Bateman-Hall Admixtures: N/A Contractor: Bryan Landon Supplier: Walters Ready Mix Mix Number: N-172F1 U Date: 5/3/2023 Cylinder Log #: 170 Field Test Results: Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 74 Ambient Temperature (°F): 39 Unit Weight (PCF): 146.4 Tested By: B. Choffin Date: 5/3/2023 Picked Up By: B. Choffin Date: 5/4/2023 Time: 11:40 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 5/10/2023 12.56 60580 4823 4,000.00 Type 1 File name: 22247SB05312023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 83D10B52-3890-4624-9EAF-E8D835DD72C3 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 5/31/2023 4.000 12.56 75,595.0 6019 4,000.0 Type 3 C 28 5/31/2023 4.000 12.56 74,125.0 5902 4,000.0 Type 1 D 28 5/31/2023 4.000 12.56 73,630.0 5862 4,000.0 Type 3 Second Break Average: 5928 Date: 05/31/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8EE06C7F-445C-445F-80EB-6527F5406064 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 7.2 Ticket #: 05076 Project Name: U-Haul Moving and Storage Test Location: Building A slab approx. A-17 Client: Bateman-Hall Admixtures: MS-AC-534, MP-322 Required 28 day Strength (psi): 4,000.0 Supplier: Walter’s Ready Mix Mix Number: W-172FI U Date: 06/01/2023 Start Time 04:30 AM End Time 08:15 AM Testing: Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 7.2 06:10 AM Building A slab approx. A-17 45 34.200 137.3 68 1.5 N/A 5.5 6 Max Observations/Remarks: I arrived on site around 4:45 AM. Shortly after arriving and parking, I exited my vehicle and began to inspect the rebar placement, and found it to be within general conformance to project guidelines. Afterwards I began to setup my testing equipment and wait for the first trucks arrival. The first truck arrived at 5:00 AM. I grabbed my sample between 5:10-5:15 AM. I concluded all of my tests with satisfactory results and informed the contractor of the results. I observed the contractor use all of the correct procedures to make sure the concrete had the right displacement, as well as the correct level and finish. They used mechanical vibration for the correct displacement of the material. PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8EE06C7F-445C-445F-80EB-6527F5406064 2 Tested By: B. Choffin Signature: Reviewed By: Luke Hammar Signature: Date: 06/01/2023 Inspection Images PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8EE06C7F-445C-445F-80EB-6527F5406064 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E4259BC3-BE4F-45E2-87A1-3BF020F1E047 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 30.0 Ticket #: 05080 Project Name: U-Haul Moving and Storage Test Location: Building A Gridline C:31 Client: Bateman-Hall Admixtures: MS AC 534, MP 322, MA AE 90 Required 28 day Strength (psi): 3,500.0 Supplier: Walters Ready Mix, Inc. Mix Number: 142-3500 Date: 06/01/2023 Start Time 04:30 AM End Time 08:30 AM Testing: Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 30.0 05:55 AM Building A Gridline C: 31 46 35.700 143.4 68 5.0 N/A 6 8 Max 2 60.0 06:55 AM Building A Gridline A: 12 (Middle of A and B) 47 35.520 142.7 65 4.5 N/A 6 8 Max Observations/Remarks: I arrived on site at approximately 4:55 AM and proceeded to immediately set up my testing equipment in preparation for testing. As soon as my gear was prepared, I acquired a sample from the first truck at approximately 5:20 AM. When testing this sample the air quality was .5% lower than passing. The truck had already finished pouring by the time the test was completed. I then tested the third truck at approximately 5:55 AM and found all tests to be passing within the given parameters. When the sixth truck arrived I tested it and found it also to be passing PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E4259BC3-BE4F-45E2-87A1-3BF020F1E047 2 within all given parameters. I then cleaned all of my equipment and gear. I noted that the workers made sure that the concrete was set correctly well after it was poured. I also noted they used a mechanical vibrating machine to ensure the concrete was consolidated correctly. Tested By: Michael Hammar Signature: Reviewed By: Luke Hammar Signature: Date: 06/01/2023 Inspection Images PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E4259BC3-BE4F-45E2-87A1-3BF020F1E047 3 File name: 22247FB06012023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 259A5448-B8B3-4931-9E86-9C247B9E6D9B 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 2.25 Project Name: U-Haul Moving and Storage Test Location: Elevator shaft @ 12 Client: Bateman-Hall Admixtures: N/A Ticket Number: 4954 Contractor: JW Masonry Supplier: Walters Ready Mix, Inc. Mix Number: 41 Date: 5/25/2023 Cylinder Log #: 214 Field Test Results: Set #: 1 Entrained Air (%): 0.0 Concrete Temperature (°F): 73 Ambient Temperature (°F): 67 Unit Weight (PCF): 0 Tested By: Luke Hammar Date: 5/25/2023 Picked Up By: Jense Christensen Date: 5/26/2023 Time: 9:44 AM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/1/2023 3.390 9.02 39,010.0 4325 3,500.0 Type 3 Date: 06/01/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB06042023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 46B86A57-3174-4179-979F-F02BA32EDCD8 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 30.0 Project Name: U-Haul Moving and Storage Test Location: Building A Gridline C:31 Client: Bateman-Hall Admixtures: MS AC 534, MP 322, MA AE 90 Ticket Number: 5080 Contractor: Bryan Landon Supplier: Walters Ready Mix, Inc. Mix Number: 142-3500 Date: 6/1/2023 Cylinder Log #: 228 Field Test Results: Set #: 2 Entrained Air (%): 5.0 Concrete Temperature (°F): 68 Ambient Temperature (°F): 46 Unit Weight (PCF): 143.4 Tested By: Michael Hammar Date: 6/1/2023 Picked Up By: Jense Christensen Date: 6/2/2023 Time: 11:00 AM Max, Min Temperature 81,59 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 3 6/4/2023 4.000 12.56 45,380.0 3613 3,500.0 Type 1 Date: 06/05/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB06032023JPC set2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. C7301A63-F97C-42CB-A908-5E34B07098ED 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 60.0 Project Name: U-Haul Moving and Storage Test Location: Building A Gridline A:12 (Middle of A and B) Client: Bateman-Hall Admixtures: MS AC 534, MP 322, MA AE 90 Ticket Number: 5084 Contractor: Bryan Landon Supplier: Walters Ready Mix, Inc. Mix Number: 142-3500 Date: 6/1/2023 Cylinder Log #: 229 Field Test Results: Set #: 3 Entrained Air (%): 4.5 Concrete Temperature (°F): 65 Ambient Temperature (°F): 47 Unit Weight (PCF): 142.7 Tested By: Michael Hammar Date: 6/1/2023 Picked Up By: Jense Christensen Date: 6/2/2023 Time: 11:23 AM Max, Min Temperature 81,59 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 3 6/4/2023 4.000 12.56 44,910.0 3576 3,500.0 Type 2 Date: 06/05/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB06082023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5FF90E52-3F16-47BA-AD59-17ABB9B12875 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 60 Project Name: U-Haul Moving and Storage Test Location: Building A Gridline A:12 (Middle of A and B) Client: Bateman-Hall Admixtures: MS AC 534, MP 322, MA AE 90 Contractor: Bryan Landon Supplier: Walters Ready Mix, Inc. Mix Number: 142-3500 Date: 6/1/2023 Cylinder Log #: 229 Field Test Results: Set #: 3 Entrained Air (%): 4.5 Concrete Temperature (°F): 65 Ambient Temperature (°F): 47 Unit Weight (PCF): 142.7 Tested By: Michael Hammar Date: 6/1/2023 Picked Up By: Jense Christensen Date: 6/2/2023 Time: 11:23 AM Max, Min Temperature 81,59 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 3 6/4/2023 12.56 44910 3576 3,500.00 Type 2 File name: 22247SB06082023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5FF90E52-3F16-47BA-AD59-17ABB9B12875 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 7 6/8/2023 4.000 12.56 57,430.0 4572 3,500.0 Type 3 Second Break Average: 4572 Date: 06/08/2023 Reviewed By: Luke Hammar Signature: File Name 22247C06152023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A8716F72-5906-495F-8021-07FCAE25AA39 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Ticket #: 22411642 Project Name: U-Haul Moving and Storage Test Location: See photo in reference to pg C6 on the plans Concrete Member: Exterior Slab Client: Bateman-Hall Admixtures: N/A Required 28 day Strength (psi): 4,000.0 Contractor Bryant Greene Construction Supplier: Knife River Mix Number: IF CL40 BF Date: 06/15/2023 Start Time 07:45 AM End Time 09:45 AM Testing: Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 10.0 08:15 AM See photo in reference to pg C6 on the plans 50 35.160 141.2 64 5.5 6 +- 1.5 4 1/2 8 Max Observations/Remarks: I arrived at the job site around 7:45 AM. I looked over the forms and spoke with the foreman about the mix and the supplier. I returned to my vehicle and began setting up my equipment. The truck showed up just after 8:00 AM and I was able to grab the batch ticket. Mike with Knife River showed up shortly after. I observed as they offloaded some of the mix and was able to grab a sample after they offloaded about a yard. I returned to my vehicle to begin testing air and slump. Mike observed as I tested and recorded results as I got File Name 22247C06152023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A8716F72-5906-495F-8021-07FCAE25AA39 2 them. The air content as well as the slump results were within general conformance with the jobs parameters. And I reported said results to Mike as stated earlier. I then cast strength specimens and I observed the remainder of the pour. I then returned to my vehicle and began filling out my report. Tested By: M.Mansfield Signature: Reviewed By: Luke Hammar Signature: Date: 06/16/2023 Inspection Images File Name 22247C06152023MM PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A8716F72-5906-495F-8021-07FCAE25AA39 3 File Name 22247C06162023MH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 61A5461F-6D5A-4BEF-9D11-24CFB8ABFF95 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Ticket #: 22411717 Project Name: U-Haul Moving and Storage Test Location: North Valley Gutters Concrete Member: Site Elements Client: Bateman-Hall Admixtures: N/A Required 28 day Strength (psi): 3,500.0 Contractor Bryan Landon Construction Supplier: Knife River Mix Number: C401G456 Date: 06/16/2023 Start Time 08:40 AM End Time 09:20 AM Testing: Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 10.0 08:50 AM North Valley Gutters 54 35.200 141.4 63 7.0 6 +- 1.5 3.5 8 Max Observations/Remarks: I arrived on site at approximately 4:15 AM for a different pour on the same project, so I was already present with gear set up for this pour. The truck arrived at approximately 8:40 AM and immediately prepared to pour. Once a sufficient amount had been poured, I collected a sample for testing. The tests I performed were in general conformance with project specifications and were reported to the contractor. I then cleaned my gear and began this report. Tested By:Reviewed By: File Name 22247C06162023MH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 61A5461F-6D5A-4BEF-9D11-24CFB8ABFF95 2 Michael Hammar Signature: Luke Hammar Signature: Date: 06/16/2023 Inspection Images File Name 22247C06142023MH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E6F9B0FA-42BB-4355-A527-673ED015CCE7 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Ticket #: 22411597 Project Name: U-Haul Moving and Storage Test Location: Valley Gutter, 5 Ft south of building I. Concrete Member: Site Elements Client: Bateman-Hall Admixtures: Required 28 day Strength (psi): 3,500.0 Contractor Bryan Landon Construction Supplier: Knife River Mix Number: C401G456 Date: 06/14/2023 Start Time 10:45 AM End Time 01:25 PM Testing: Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 10.0 12:00 PM Valley Gutter, 5 Ft south of building I. 65 35.140 141.1 70 6.0 6 +- 1.5 4 8 Max Observations/Remarks: I arrived on site at approximately 11:20 AM and set up my equipment in preparation for testing. I then met with the contractor to inform him I would be testing. The truck arrived at approximately 11:55 AM and immediately began preparing to pour. Once a sufficient amount had been poured, I collected my sample for testing. The tests I performed were in general conformance with project specifications. I then reported the results to the contractor. I then proceeded to clean my gear and enter my vehicle to begin this report. Tested By:Reviewed By: File Name 22247C06142023MH PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. E6F9B0FA-42BB-4355-A527-673ED015CCE7 2 Michael Hammar Signature: Luke Hammar Signature: Date: 06/16/2023 Inspection Images File Name 22247C06162023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BDE2DCE6-5FA4-4977-A639-3FE06009689A 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10.0 Ticket #: 05565 Project Name: U-Haul Moving and Storage Test Location: Building B slab Concrete Member: Interior Slab Client: Bateman-Hall Admixtures: MS AC 534, Delvo, MP 322 Required 28 day Strength (psi): 4,000.0 Contractor Bryan Landon Construction Supplier: Walter’s Ready Mix, Inc. Mix Number: 1421 4000 Date: 06/16/2023 Start Time 04:00 AM End Time 01:15 PM Testing: Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): 1 10.0 04:45 AM Building B slab 42 35.800 143.8 71 1.5 N/A 6 6 Max 2 70.0 05:05 AM Building B slab 42 36.180 145.3 67 1.9 N/A 7 6 Max 3 110.0 05:40 AM Building B slab 43 35.860 144.0 67 1.9 N/A 6.5 6 Max 4 150.0 06:30 AM Building B slab 45 36.300 145.8 65 1.9 N/A 6.5 6 Max 5 200.0 07:15 AM Building B slab 48 36.300 145.8 66 1.9 N/A 6 6 Max 6 280.0 08:15 AM Building B slab 53 36.600 147.0 67 1.5 N/A 6 6 Max 7 320.0 08:50 AM Building B slab 55 36.400 146.2 68 1.5 N/A 6.5 6 Max 8 370.0 09:00 AM Building B slab 56 36.080 144.9 69 2.0 N/A 7 6 Max 9 400.0 09:40 AM Building B 59 36.600 147.0 69 1.7 N/A 6.5 6 Max File Name 22247C06162023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BDE2DCE6-5FA4-4977-A639-3FE06009689A 2 Set #:Cumulative Test Load Amount: Time Tested: Test Location: Ambient Temp. (°F): Weight of Concrete (lbs): Unit Weight (PCF): Concrete Temp. (°F): Entrained Air (%): Entrained Air Spec. (%): Slump (in): Slump Spec. (in): slab 10 460.0 10:25 AM Building B slab 61 36.540 146.7 71 1.5 N/A 6.5 6 Max 11 510.0 11:10 AM Building B slab 63 36.560 146.8 73 2.0 N/A 6 6 Max 12 560.0 12:00 PM Building B slab 65 36.360 146.0 75 2.0 N/A 6 6 Max Observations/Remarks: I arrived on site around 4:20 AM. I exited my truck and began to inspect the rebar placement within Building B and found it to be within project specifications. The first truck arrived around 4:40 AM. I sampled and performed a concrete field test. I reported my results to the contractor. I then took a sample every 50 yards performing a field test with each sample. Strength specimens were made for each sample that was taken. I observed the contractor place the concrete. Tested By: B. Choffin Signature: Reviewed By: Luke Hammar Signature: Date: 06/16/2023 Inspection Images File Name 22247C06162023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BDE2DCE6-5FA4-4977-A639-3FE06009689A 3 File Name 22247C06162023BC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. BDE2DCE6-5FA4-4977-A639-3FE06009689A 4 File name: 22247FB06162023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7A59D876-CEB2-4AB0-A18D-4DB56BA65AA7 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Approx. 300 South of Northwest corner of Building B. Client: Bateman-Hall Admixtures: MS AC 534, MP 322 Ticket Number: 5353 Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc. Mix Number: W172FI 35 Date: 6/9/2023 Cylinder Log #: 244 Field Test Results: Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 70 Ambient Temperature (°F): 48 Unit Weight (PCF): 145.1 Tested By: B. Choffin Time Tested: 08:07 AM Picked Up By: Jense Christensen Date: 6/10/2023 Time: 1:00 PM Max, Min Temperature 80, 60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/16/2023 4.000 12.57 50,615.0 4027 4,000.0 Type 6 Date: 06/16/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB06222023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 63036855-9BA9-486D-8111-912D7636CCB8 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 2.2 Project Name: U-Haul Moving and Storage Test Location: Elevator shaft @ 12 Client: Bateman-Hall Admixtures: N/A Contractor: JW Masonry Supplier: Walters Ready Mix, Inc. Mix Number: 41 Date: 5/25/2023 Cylinder Log #: 214 Field Test Results: Set #: 1 Entrained Air (%): 0.0 Concrete Temperature (°F): 73 Ambient Temperature (°F): 67 Unit Weight (PCF): 0 Tested By: Luke Hammar Date: 5/25/2023 Picked Up By: Jense Christensen Date: 5/26/2023 Time: 9:44 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/1/2023 9.02 39010 4325 3,500.00 Type 3 File name: 22247SB06222023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 63036855-9BA9-486D-8111-912D7636CCB8 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 6/22/2023 3.450 9.34 50,640.0 5422 3,500.0 Type 3 C 28 6/22/2023 3.410 9.13 49,155.0 5384 3,500.0 Type 6 D 28 6/22/2023 3.430 9.24 48,120.0 5208 3,500.0 Type 3 Second Break Average: 5338 Date: 06/22/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB06222023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 643561AF-01E1-45BE-A29E-D4C1A0FA91CA 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Valley gutter, 5 ft. south of building 1. Client: Bateman-Hall Admixtures: AE200, POLY980 Ticket Number: 22411597 Contractor: Bryan Landon Construction Supplier: Knife River Mix Number: C401G456 Date: 6/14/2023 Cylinder Log #: 276 Field Test Results: Set #: 1 Entrained Air (%): 6.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 65 Unit Weight (PCF): 141.1 Tested By: Michael Hammar Time Tested: 08:10 AM Picked Up By: Jense Christensen Date: 6/15/2023 Time: 1:38 PM Max, Min Temperature 80,60 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/21/2023 4.000 12.57 44,360.0 3529 3,500.0 Type 6 Date: 06/22/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB06232023JPC13 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 3DC127AE-782F-4A07-8B42-D58B8DB2265E 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 560 Project Name: U-Haul Moving and Storage Test Location: Building B slab Client: Bateman-Hall Admixtures: MS AC 534, Delvo, MP 322 Ticket Number: 5623 Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc. Mix Number: 1421 4000 Date: 6/16/2023 Cylinder Log #: 275 Field Test Results: Set #: 13 Entrained Air (%): 2.0 Concrete Temperature (°F): 75 Ambient Temperature (°F): 65 Unit Weight (PCF): 146 Tested By: B. Choffin Time Tested: 09:59 AM Picked Up By: Jense Christensen Date: 6/17/2023 Time: 1:30 PM Max, Min Temperature 80,62 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/23/2023 4.000 12.57 62,835.0 4999 4,000.0 Type 3 Date: 06/23/2023 Reviewed By: Luke Hammar Signature: File name: 22247FB06232023JPC12 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7E1E6BC9-C65D-4FDE-877F-E865BEA804B4 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 510 Project Name: U-Haul Moving and Storage Test Location: Building B slab Client: Bateman-Hall Admixtures: MS AC 534, Delvo, MP 322 Ticket Number: 5618 Contractor: Bryan Landon Construction Supplier: Walters Ready Mix, Inc. Mix Number: 1421 4000 Date: 6/16/2023 Cylinder Log #: 274 Field Test Results: Set #: 12 Entrained Air (%): 2.0 Concrete Temperature (°F): 73 Ambient Temperature (°F): 63 Unit Weight (PCF): 146.8 Tested By: B. Choffin Time Tested: 09:56 AM Picked Up By: Jense Christensen Date: 6/17/2023 Time: 1:30 PM Max, Min Temperature 80,62 Initial Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/23/2023 4.000 12.57 61,135.0 4864 4,000.0 Type 1 Date: 06/23/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB06282023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 00990AAE-1114-4CFF-9FB4-E7C3C6685A7B 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 10 Project Name: U-Haul Moving and Storage Test Location: Building A Gridline E:9 Client: Bateman-Hall Admixtures: MS AC 534, MP 322, MA AE 90 Contractor: Bryan Landon Supplier: Walters Ready Mix, Inc. Mix Number: 142-3500 Date: 5/31/2023 Cylinder Log #: 222 Field Test Results: Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 69 Ambient Temperature (°F): 46 Unit Weight (PCF): 141 Tested By: M. Hammar Date: 5/31/2023 Picked Up By: Jense Christensen Date: 6/1/2023 Time: 9:00 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/7/2023 12.57 54315 4321 3,500.00 Type 2 File name: 22247SB06282023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 00990AAE-1114-4CFF-9FB4-E7C3C6685A7B 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 6/28/2023 4.000 12.57 66,110.0 5259 3,500.0 Type 3 C 28 6/28/2023 4.000 12.57 66,400.0 5282 3,500.0 Type 1 D 28 6/28/2023 4.000 12.57 66,705.0 5307 3,500.0 Type 2 Second Break Average: 5283 Date: 06/28/2023 Reviewed By: Luke Hammar Signature: File name: 22247SB06282023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5C362763-2F5A-4093-BAF1-3B7DB799A3CB 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 Compressive Strength of Concrete Test Specimens Project Number: 22-247 Cumulative Test Load Amount: 60 Project Name: U-Haul Moving and Storage Test Location: Building A Gridline D:14 Client: Bateman-Hall Admixtures: MS AC 534, MP 322, MA AE 90 Contractor: Bryan Landon Supplier: Walters Ready Mix, Inc. Mix Number: 142-3500 Date: 5/31/2023 Cylinder Log #: 223 Field Test Results: Set #: 2 Entrained Air (%): 5.0 Concrete Temperature (°F): 68 Ambient Temperature (°F): 50 Unit Weight (PCF): 141.4 Tested By: M. Hammar Date: 5/31/2023 Picked Up By: Jense Christensen Date: 6/1/2023 Time: 9:00 AM Max, Min Temperature 80, 60 Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/7/2023 12.57 51105 4066 3,500.00 Type 1 File name: 22247SB06282023JPC PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 5C362763-2F5A-4093-BAF1-3B7DB799A3CB 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 6/28/2023 4.000 12.57 61,175.0 4867 3,500.0 Type 1 C 28 6/28/2023 4.000 12.57 62,765.0 4993 3,500.0 Type 3 D 28 6/28/2023 4.000 12.57 61,785.0 4915 3,500.0 Type 3 Second Break Average: 4925 Date: 06/28/2023 Reviewed By: Luke Hammar Signature: