Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Ticket #:
02793
Project Name:
U-Haul Moving and Storage
Test Location:
Footings, Southeast corner
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-170FI U
Date:
12/07/2022
Start Time
10:00 AM
End Time
01:45 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 11:15
AM
02793 Footings,
Southeast
corner
24 143.5 1.7 N/A 60 8 Max
2 12:15
PM
02797 50 feet
west of
the
northeast
corner of
the
footings
26 145.1 2.1 N/A 57 8 M
Observations/Remarks:
I arrived on site and began observations on the reinforcement for the footings from the southeast corner to the
northeast corner and to 300 feet west of the northeast corner of the main building. I looked for overlap,
clearance, correctness, and overall uniformity. I also made sure the reinforcement was lifted off the ground.
I observed that the reinforcement was within general conformance to project guidelines. I observed the
contractor manually tie the reinforcement and place it on the ground.
When I arrived I noted that the area being poured had been covered with concrete blankets the night before. At
11:10 AM the first truck arrived and I took a sample after approximately one yard had been expelled from the
File Name
22247C12072022CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
572538EC-49EE-4433-8485-B3122C9C91F7 2
truck.
I performed a concrete field test and observed that the results of the test were within general conformance to
project guidelines. I proceeded to take another sample from the fifth truck after approximately one yard had
been expelled from the truck. With this sample I performed a concrete field test. I observed the results of the
test within general conformance to project guidelines.
With each sample I made concrete test specimens and placed them in a cooler with heated water near the
footings to be covered with blankets and heated, I remained on site for the duration of the pour and reported my
results to the contractor then left the site.
Tested By:
C Hammar
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
12/07/2022
Inspection Images
File Name
22247C12072022CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
572538EC-49EE-4433-8485-B3122C9C91F7 3
File Name
22247C12132922CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
34A600D4-A292-473B-88A6-7BCF77EE0426 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Ticket #:
02871
Project Name:
U-Haul Moving and Storage
Test Location:
Footings southwest section of building
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-170FI U
Date:
12/13/2022
Start Time
11:00 AM
End Time
02:00 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 12:00
PM
02871 Footings
southwest
section of
building
28 145.0 1.7 N/A 59 8 Max
Observations/Remarks:
Arrived on site and began observations on the reinforcement for half of the northern side of the footings and the
entirety of the western side. I looked for uniformity, overlap, clearance, and overall correctness. I observed that
the reinforcement was within general conformance to project guidelines, and that it was lifted up and off the
ground.
I observed that the contractor covered and heated the ground preparatory to concrete poured today. The truck
arrived at 11:55 AM and I took a sample at 12:00 PM. with the sample I performed a concrete field test and
made concrete test specimens.
I observed the results of the tests were within general conformance to project guidelines, and I reported my
results to the contractor.
I left the concrete test specimens in a cooler with heated water next to the footings to be covered and heated
overnight then left the jobsite.
File Name
22247C12132922CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
34A600D4-A292-473B-88A6-7BCF77EE0426 2
Tested By:
C Hammar
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
12/14/2022
Inspection Images
File Name
22247C12132922CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
34A600D4-A292-473B-88A6-7BCF77EE0426 3
File name:
22247CFB12142022CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
4A1F2855-7B11-40A5-86BB-78F16807A7A2 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
50 feet west of the northeast corner of the footings
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
2797
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-170FI U
Date:
12/7/2022
Cylinder Log #:
791
Field Test Results:
Set #:
2
Slump
Maximum
(in):
Entrained Air
(%):
2.1
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
57
Ambient
Temperature
(°F):
26
Unit Weight
(PCF):
145.1
Tested By:
C. Hammar
Date:
12/7/2022
Picked Up By:
E. Vail
Date:
12/9/2022
Time:
10:15 AM
Max, Min Temperature
91, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/14/2022 4.000 12.56 34,210.0 2724 3,500.0 Type 1
Date:
12/14/2022
Reviewed By:
Luke Hammar
Signature:
File name:
22247CFB12142022CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
9C19DE98-94D3-4F40-AD4A-F2C5D4D02698 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Footings, Southeast corner
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
2793
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-170FI U
Date:
12/7/2022
Cylinder Log #:
790
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.7
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
60
Ambient
Temperature
(°F):
24
Unit Weight
(PCF):
143.5
Tested By:
C. Hammar
Date:
12/7/2022
Picked Up By:
E. Vail
Date:
12/9/2022
Time:
10:00 AM
Max, Min Temperature
91, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/14/2022 4.000 12.56 46,555.0 3707 3,500.0 Type 6
Date:
12/14/2022
Reviewed By:
Luke Hammar
Signature:
File Name
22247C12162022CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1893123A-4D83-4D44-BD82-A39D6806204B 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Ticket #:
02914
Project Name:
U-Haul Moving and Storage
Test Location:
Western most footing
Client:
Bateman-Hall
Admixtures:
NA
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bryan Landon
Supplier:
Walter’s Ready Mix
Mix Number:
W-170FI U
Date:
12/16/2022
Start Time
11:30 AM
End Time
02:00 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 12:30
PM
02914 Western
most
footing
14 145.0 1.7 N/A 51 8 Max
Observations/Remarks:
I arrived on site and began observations on the footings north and west for the main building.
When I arrived the third truck was in the middle of pouring and almost finished. I waited to take a test from the
fourth truck. At 12:25 PM I received a sample after approximately 1 yard had been expelled from the fourth
truck.
With the sample I performed a concrete field test and made concrete test specimens. I observed that the results
of the test were within general conformance to project guidelines.
I reported my results to the contractor and left the job site. Prior to pouring I noted that the contractor had
covered the ground to be poured and had heated it overnight.
Tested By:
C Hammar
Signature:
Reviewed By:
Luke Hammar
Signature:
File Name
22247C12162022CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1893123A-4D83-4D44-BD82-A39D6806204B 2
Date:
12/16/2022
Inspection Images
File name:
22247FB12202022EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
5AE4E250-6253-42D1-B655-DF7B0079650C 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11
Project Name:
U-Haul Moving and Storage
Test Location:
Footings southwest section of building
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
2871
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-170FI U
Date:
12/13/2022
Cylinder Log #:
797
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.7
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
59
Ambient
Temperature
(°F):
28
Unit Weight
(PCF):
145
Tested By:
C. Hammar
Date:
12/13/2022
Picked Up By:
Ben E Ball
Date:
12/14/2022
Time:
10:11 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/20/2022 4.000 12.56 48,290.0 3845 3,500.0 Type 1
Date:
12/21/2022
Reviewed By:
Luke Hammar
Signature:
File Name
22247C12232022CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
101D9E1B-D0F4-43A8-B279-DBAD01E7CDD6 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
5.0
Ticket #:
02951
Project Name:
U-Haul Moving and Storage
Test Location:
Small foundation wall interior middle
Client:
Bateman-Hall
Admixtures:
X-SEED, MS AC 534, MP
322, MA AE 90
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W172F 350
Date:
12/23/2022
Start Time
09:00 AM
End Time
12:30 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 10:50
AM
02951 Small
foundation
wall
interior
middle
11 137.4 7.8 6 +- 1.5 54 8 Max
Observations/Remarks:
I arrived on site and began observations on the interior square foundation wall in the north middle of the main
building. The concrete truck arrived at 10:45 AM and I received a sample at 10:50 AM after approximately 1 yard
had been expelled from the truck. With the sample, I performed a concrete field test and made concrete test
specimens. I noted that the air was a little high and informed the contractor who proceeded with the pour I
observed that the results of the tests were within general conformance to project guidelines. I reported my
results to the contractor and left the jobsite.
Tested By:
C Hammar
Signature:
Reviewed By:
Luke Hammar
Signature:
File Name
22247C12232022CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
101D9E1B-D0F4-43A8-B279-DBAD01E7CDD6 2
Date:
12/27/2022
Inspection Images
File Name
22247C12212022MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C25D7150-A6E6-4BE1-AA60-08354D6F19AA 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Ticket #:
02943
Project Name:
U-Haul Moving and Storage
Test Location:
Pad footing southeast corner of job
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP322
Required 28 day Strength
(psi):
3,500.0
Contractor:
BL construction
Supplier:
Walters
Mix Number:
W-17OFI U
Date:
12/21/2022
Start Time
10:00 AM
End Time
12:30 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 11:15
AM
02943 Pad
footing
southeast
corner of
job
30 145.0 2.0 N/A 59 8 Max
Observations/Remarks:
I arrived at the job site and met with the foreman to discuss the pour. We also talked about a good place to
setup for testing.
I prepped my gear and waited for the first truck to arrive. The first truck arrived around 10:45, I grabbed my
ticket and waited the allotted time to grab my sample. I did so and returned to my work area to begin my
testing.
My results were within spec and I reported to both the driver and the foreman.
I returned to my vehicle to clean my gear. I observed the remainder of the pour and began my report.
I left the job site around 12:45.
Tested By:
M.Mansfield
Signature:
Reviewed By:
Luke Hammar
Signature:
File Name
22247C12212022MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C25D7150-A6E6-4BE1-AA60-08354D6F19AA 2
Date:
12/27/2022
Inspection Images
File name:
22247CFB12232022CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
BA461E35-4F45-42AB-B870-17421A24AB5C 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11
Project Name:
U-Haul Moving and Storage
Test Location:
Western most footing
Client:
Bateman-Hall
Admixtures:
N/A
Ticket Number:
2914
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-170FI U
Date:
12/16/2022
Cylinder Log #:
806
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.7
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
51
Ambient
Temperature
(°F):
14
Unit Weight
(PCF):
145
Tested By:
C. Hammar
Date:
12/16/2022
Picked Up By:
M.Mansfield
Date:
12/17/2022
Time:
3:23 PM
Max, Min Temperature
80,60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/23/2022 4.000 12.56 55,615.0 4428 3,500.0 Type 6
Date:
12/28/2022
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB12282022LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F866B0AD-F362-4C3E-8CC2-02DE02C2497C 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11
Project Name:
U-Haul Moving and Storage
Test Location:
Pad footing southeast corner of job
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP322
Ticket Number:
2943
Contractor:
BL construction
Supplier:
Walters
Mix Number:
W-17OFI U
Date:
12/21/2022
Cylinder Log #:
809
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
2.0
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
59
Ambient
Temperature
(°F):
30
Unit Weight
(PCF):
145
Tested By:
M.Mansfield
Date:
12/21/2022
Picked Up By:
C Hammar
Date:
12/27/2022
Time:
10:08 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/28/2022 4.000 12.56 65,780.0 5237 3,500.0 Type 2
Date:
12/29/2022
Reviewed By:
Luke Hammar
Signature:
File Name
22247C01062023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
62BFEA64-A3C1-4BA7-8B57-C2667FCB957B 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Ticket #:
03005
Project Name:
U-Haul Moving and Storage
Test Location:
Southern foundation wall
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Required 28 day Strength
(psi):
3,500.0
Contractor:
BL Construction
Supplier:
Walters
Mix Number:
W-170FI U
Date:
01/06/2023
Start Time
11:00 AM
End Time
02:30 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 12:00
PM
03005 Southern
foundation
wall
35 145.9 1.2 N/A 51 8 Max
2 01:30
PM
03009 Southern
foundation
walls
35 145.4 1.5 6 +- 1.5 58 8 Max
Observations/Remarks:
I arrived at the job site around 11:30 am and began a rebar inspection. I found the rebar to be up to spec. I
performed other tasks while waiting for the first truck.
The first truck arrived around 12:00 pm and I was able to grab a ticket from the driver and then waited for her
to have a yard off. Once a yard was discharged I was able to grab a sample and begin testing, the results were
within spec and reported to both the driver and the foreman. I poured my cylinders and then cleaned my gear in
preparation for my second test.
The fifth truck arrived around 1:15 pm and I was able to grab a sample and begin testing around 1:30 pm.
The results were also within spec. I placed my cylinders and began cleaning my gear. I observed the remainder
of the pour.
File Name
22247C01062023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
62BFEA64-A3C1-4BA7-8B57-C2667FCB957B 2
Once the pour was concluded I returned to my vehicle to fill out my report. I left the job around 2:30 pm.
Tested By:
M.Mansfield
Signature:
Reviewed By:
E. Vail
Signature:
Date:
01/09/2023
Inspection Images
File Name
22247C01062023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
62BFEA64-A3C1-4BA7-8B57-C2667FCB957B 3
File name:
22247SB01052023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8E7CCD2C-4598-4D06-995F-A3145584AAF4 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
50 feet west of the northeast corner of the footings
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
2797
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-170FI U
Date:
12/7/2022
Cylinder Log #:
791
Field Test Results:
Set #:
2
Slump
Maximum
(in):
Entrained Air
(%):
2.1
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
57
Ambient
Temperature
(°F):
26
Unit Weight
(PCF):
145.1
Tested By:
C. Hammar
Date:
12/7/2022
Picked Up By:
E. Vail
Date:
12/9/2022
Time:
10:15 AM
Max, Min Temperature
91, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/14/2022 12.56 34210 2724 3,500.00 Type 1
File name:
22247SB01052023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8E7CCD2C-4598-4D06-995F-A3145584AAF4 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 1/4/2023 4.000 12.56 51,985.0 4139 3,500.0 Type 2
C 28 1/4/2023 4.000 12.56 50,230.0 3999 3,500.0 Type 1
D 28 1/4/2023 4.000 12.56 53,150.0 4232 3,500.0 Type 6
Second Break Average:
4123
Date:
01/11/2023
Reviewed By:
E. Vail
Signature:
File name:
22247SB01052023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1EB22F9C-3AE9-4FC9-852F-362CE18956DB 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Footings, Southeast corner
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
2793
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-170FI U
Date:
12/7/2022
Cylinder Log #:
790
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.7
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
60
Ambient
Temperature
(°F):
24
Unit Weight
(PCF):
143.5
Tested By:
C. Hammar
Date:
12/7/2022
Picked Up By:
E. Vail
Date:
12/9/2022
Time:
10:00 AM
Max, Min Temperature
91, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/14/2022 12.56 46555 3707 3,500.00 Type 6
File name:
22247SB01052023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1EB22F9C-3AE9-4FC9-852F-362CE18956DB 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 1/4/2023 4.000 12.56 62,840.0 5003 3,500.0 Type 2
C 28 1/4/2023 4.000 12.56 61,050.0 4861 3,500.0 Type 2
D 28 1/4/2023 4.000 12.56 59,485.0 4736 3,500.0 Type 1
Second Break Average:
4866
Date:
01/11/2023
Reviewed By:
E. Vail
Signature:
File name:
22247SB01102023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
D0832665-E2B8-4A77-9E0C-6681B836EFFA 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Footings southwest section of building
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
2871
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-170FI U
Date:
12/13/2022
Cylinder Log #:
797
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.7
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
59
Ambient
Temperature
(°F):
28
Unit Weight
(PCF):
145.0
Tested By:
C. Hammar
Date:
12/13/2022
Picked Up By:
Ben E Ball
Date:
12/14/2022
Time:
10:11 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/20/2022 12.56 48290 3845 3,500.00 Type 1
File name:
22247SB01102023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
D0832665-E2B8-4A77-9E0C-6681B836EFFA 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 1/10/2023 4.000 12.56 62,060.0 4941 3,500.0 Type 1
C 28 1/10/2023 4.000 12.56 61,915.0 4930 3,500.0 Type 2
D 28 1/10/2023 4.000 12.56 58,995.0 4697 3,500.0 Type 1
Second Break Average:
4856
Date:
01/11/2023
Reviewed By:
E. Vail
Signature:
File Name
22247C01112023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
4F1818E5-5A26-4F96-B459-E511535A09F0 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Ticket #:
3022
Project Name:
U-Haul Moving and Storage
Test Location:
Southwest corner of job
Client:
Bateman-Hall
Admixtures:
MP 355, MS AC 534
Required 28 day Strength
(psi):
3,500.0
Contractor:
Jerome Bowen
Supplier:
Walters Ready mix
Mix Number:
W-170FI U
Date:
01/11/2023
Start Time
11:00 AM
End Time
03:00 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 12:15
PM
3022 Southwest
corner of
job
37 146.3 1.3 N/A 61 8 Max
2 02:00
PM
3029 Southwest
corner of
job
34 146.9 1.0 N/A 62 8 Max
Observations/Remarks:
I arrived at the job site around 11:15 am and looked over the rebar and forms to make sure they were up to
spec. I found that they were.
I returned to my vehicle and setup my gear. I then waited for the first truck to show up. The first truck showed
up just before 12:00 pm. I was able to grab the ticket and then waited for the driver to discharge a yard of
material. Once that was accomplished I was able to grab my sample and begin testing.
I found the material to be within spec and I was able to report those results to the foreman. I placed my
cylinders and cleaned my gear in preparation for my next test.
I observed the pour while I waited for the fifth truck to arrive. I saw that the crew was using vibration to
consolidate the material as well as tapping on the forms.
File Name
22247C01112023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
4F1818E5-5A26-4F96-B459-E511535A09F0 2
The fifth truck arrived around 1:45 pm and I was able to grab that ticket as well as the sample once the allotted
time had passed. After running my tests I found the results to be within spec once again. I was able to pour my
cylinders and place my cooler.
Once I finished my work, I began cleaning my gear and returned to my vehicle. I began filling out my report. I
left the job site at 3:00 pm.
Tested By:
M.Mansfield
Signature:
Reviewed By:
E. Vail
Signature:
Date:
01/12/2023
Inspection Images
File name:
22247SB01132023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
89B85E56-8AD6-4DBB-B852-6896B5AEA67D 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Western most footing
Client:
Bateman-Hall
Admixtures:
N/A
Ticket Number:
2914
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-170FI U
Date:
12/16/2022
Cylinder Log #:
806
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.7
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
51
Ambient
Temperature
(°F):
14
Unit Weight
(PCF):
145.0
Tested By:
C. Hammar
Date:
12/16/2022
Picked Up By:
M.Mansfield
Date:
12/17/2022
Time:
3:23 PM
Max, Min Temperature
80,60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/23/2022 12.56 55615 4428 3,500.00 Type 6
File name:
22247SB01132023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
89B85E56-8AD6-4DBB-B852-6896B5AEA67D 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 1/13/2023 4.000 12.56 64,150.0 5107 3,500.0 Type 1
C 28 1/13/2023 4.000 12.56 70,190.0 5588 3,500.0 Type 1
D 28 1/13/2023 4.000 12.56 67,850.0 5402 3,500.0 Type 2
Second Break Average:
5366
Date:
01/13/2023
Reviewed By:
E. Vail
Signature:
File name:
22247FB01132023EV2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
425746A8-F8C2-4A61-8A9B-5ED3AB7DB1F5 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
55.0
Project Name:
U-Haul Moving and Storage
Test Location:
Southern foundation walls
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
3009
Contractor:
BL Construction
Supplier:
Walters
Mix Number:
W-170FI U
Date:
1/6/2023
Cylinder Log #:
4
Field Test Results:
Set #:
2
Slump
Maximum
(in):
Entrained Air
(%):
1.5
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
58
Ambient
Temperature
(°F):
35
Unit Weight
(PCF):
145.4
Tested By:
M.Mansfield
Date:
1/6/2023
Picked Up By:
M.Mansfield
Date:
1/7/2023
Time:
9:00 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/13/2023 4.000 12.56 38,020.0 3027 3,500.0 Type 1
Date:
01/13/2023
Reviewed By:
E. Vail
Signature:
File name:
22247FB01132023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
70ABD7F3-5E7B-4D7C-9E1A-D848A9A80439 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Southern foundation wall
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
3005
Contractor:
BL Construction
Supplier:
Walters
Mix Number:
W-170FI U
Date:
1/6/2023
Cylinder Log #:
3
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.2
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
51
Ambient
Temperature
(°F):
35
Unit Weight
(PCF):
145.9
Tested By:
M.Mansfield
Date:
1/6/2023
Picked Up By:
M.Mansfield
Date:
1/7/2023
Time:
9:00 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/13/2023 4.000 12.56 42,365.0 3373 3,500.0 Type 2
Date:
01/13/2023
Reviewed By:
E. Vail
Signature:
File name:
22247SB01182023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F3433CC1-8E63-436E-A4D0-294687BFB778 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Pad footing southeast corner of job
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP322
Ticket Number:
2943
Contractor:
BL construction
Supplier:
Walters
Mix Number:
W-17OFI U
Date:
12/21/2022
Cylinder Log #:
809
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
2.0
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
59
Ambient
Temperature
(°F):
30
Unit Weight
(PCF):
145.0
Tested By:
M.Mansfield
Date:
12/21/2022
Picked Up By:
C Hammar
Date:
12/27/2022
Time:
10:08 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/28/2022 12.56 65780 5237 3,500.00 Type 2
File name:
22247SB01182023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F3433CC1-8E63-436E-A4D0-294687BFB778 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 1/18/2023 4.000 12.56 77,030.0 6133 3,500.0 Type 2
C 28 1/18/2023 4.000 12.56 78,555.0 6254 3,500.0 Type 2
D 28 1/18/2023 4.000 12.56 75,970.0 6049 3,500.0 Type 1
Second Break Average:
6145
Date:
01/18/2023
Reviewed By:
E. Vail
Signature:
File name:
22247FB01182023EV2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
3D7A3286-B651-4B06-88BD-4D2AB7D4B9AD 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
51.5
Project Name:
U-Haul Moving and Storage
Test Location:
Southwest corner of job
Client:
Bateman-Hall
Admixtures:
MP 355, MS AC 534
Ticket Number:
3029
Contractor:
Jerome Bowen
Supplier:
Walters Ready mix
Mix Number:
W-170FI U
Date:
1/11/2023
Cylinder Log #:
10
Field Test Results:
Set #:
2
Slump
Maximum
(in):
Entrained Air
(%):
1.0
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
62
Ambient
Temperature
(°F):
34
Unit Weight
(PCF):
146.9
Tested By:
M.Mansfield
Date:
1/11/2023
Picked Up By:
E. Vail
Date:
1/13/2023
Time:
11:30 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/18/2023 4.000 12.56 39,605.0 3153 3,500.0 Type 1
Date:
01/18/2023
Reviewed By:
E. Vail
Signature:
File name:
22247FB01182023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
3E945162-E51D-49FB-8F21-E7C683557A92 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Southwest corner of job
Client:
Bateman-Hall
Admixtures:
MP 355, MS AC 534
Ticket Number:
3022
Contractor:
Jerome Bowen
Supplier:
Walters Ready mix
Mix Number:
W-170FI U
Date:
1/11/2023
Cylinder Log #:
9
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.3
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
61
Ambient
Temperature
(°F):
37
Unit Weight
(PCF):
146.3
Tested By:
M.Mansfield
Date:
1/11/2023
Picked Up By:
E. Vail
Date:
1/13/2023
Time:
11:15 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/18/2023 4.000 12.56 54,000.0 4299 3,500.0 Type 1
Date:
01/18/2023
Reviewed By:
E. Vail
Signature:
File Name
22247C01192023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
4291A454-1DC8-4998-BB45-0841F716835F 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
33.0
Ticket #:
03084
Project Name:
U-Haul Moving and Storage
Test Location:
Building B footings, 40’ north of SE corner.
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bateman-Hall
Supplier:
Walters
Mix Number:
W-170FI U
Date:
01/19/2023
Start Time
09:00 AM
End Time
12:00 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 09:45
AM
03084 Building B
footings,
40’ north
of SE
corner.
23 141.4 1.2 N/A 56 8 Max
2 10:30
AM
03088 Building B
footings,
10’ south
of NE
corner.
23 140.2 1.1 N/A 51 8 Max
Observations/Remarks:
I arrived on site around 9:30 am and was able to check in with Bateman-Hall to see where the best place to set
up would be. I parked and set up my testing equipment.
As we were given late notice, I was only able to obtain a sample from the third truck instead of the first. I tested
for air, slump, and temp. All were within the given specs. After testing I made strength cylinders.
I was also able to test the sixth truck in line and the results were acceptable as well. Results were passed on to
Bateman-Hall as well as Walters Ready Mix. While observing the remainder of the pour, I noticed that mechanical
vibration was being utilized throughout the pour.
File Name
22247C01192023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
4291A454-1DC8-4998-BB45-0841F716835F 2
I left location at 11:45 am.
Tested By:
E. Vail
Signature:
Reviewed By:
E. Vail
Signature:
Date:
01/19/2023
Inspection Images
File name:
22247SB01202023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
85D70DB5-F492-437E-9AE2-9A829A3AE695 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
5.0
Project Name:
U-Haul Moving and Storage
Test Location:
Small foundation wall interior middle
Client:
Bateman-Hall
Admixtures:
X-SEED, MS AC 534, MP
322, MA AE 90
Ticket Number:
2951
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W172F 350
Date:
12/23/2022
Cylinder Log #:
810
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
7.8
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
54
Ambient
Temperature
(°F):
11
Unit Weight
(PCF):
137.4
Tested By:
C. Hammar
Date:
12/23/2022
Picked Up By:
C Hammar
Date:
12/27/2022
Time:
10:17 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 12/30/2022 12.56 36470 2904 3,500.00 Type 2
File name:
22247SB01202023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
85D70DB5-F492-437E-9AE2-9A829A3AE695 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 1/20/2023 4.000 12.56 46,815.0 3727 3,500.0 Type 1
C 28 1/20/2023 4.000 12.56 48,220.0 3839 3,500.0 Type 1
D 28 1/20/2023 4.000 12.56 49,195.0 3917 3,500.0 Type 3
Second Break Average:
3828
Date:
01/23/2023
Reviewed By:
E. Vail
Signature:
File Name
22247C01252023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
6825D786-226E-440A-87A8-6A400B8E76A7 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Ticket #:
3156
Project Name:
U-Haul Moving and Storage
Test Location:
Building D foundation wall. 15’ north of SE corner of
building.
Client:
Bateman-Hall
Admixtures:
MS AC 534, MA AE 90, MP
322
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bateman-Hall
Supplier:
Walters
Mix Number:
W172F 350
Date:
01/25/2023
Start Time
11:00 AM
End Time
01:15 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 11:30
AM
3156 Building D
foundation
wall. 15’
north of
SE corner
of
building.
13 138.8 5.9 6 +- 1.5 59 8 Max
Observations/Remarks:
I arrived on site around 10:30 am with enough time to look over the forms and rebar. Spacing and size appeared
to be correct.
Concrete showed up right on time at 11:00 am and after displacing a yard, I was able to obtain a sample for
testing. I tested for air, slump, and temp. All were within spec. I reported that back to Walters and Bateman-
Hall.
After making strength cylinders I cleaned up my gear and observed the duration of the pour. I did notice that
mechanical vibration was used on the walls.
File Name
22247C01252023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
6825D786-226E-440A-87A8-6A400B8E76A7 2
Tested By:
E. Vail
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
01/26/2023
Inspection Images
File name:
22247FB01262023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1CB74BB7-A6D0-46ED-B486-5F5802F95CB1 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
33
Project Name:
U-Haul Moving and Storage
Test Location:
Building B footings, 40' north of SE corner.
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
3084
Contractor:
Bateman-Hall
Supplier:
Walters
Mix Number:
W-170FI U
Date:
1/19/2023
Cylinder Log #:
20
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.2
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
56
Ambient
Temperature
(°F):
23
Unit Weight
(PCF):
141.4
Tested By:
E. Vail
Date:
1/19/2023
Picked Up By:
Luke Hammar
Date:
1/20/2023
Time:
10:01 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/26/2023 4.000 12.56 31,765.0 2529 3,500.0 Type 2
Date:
01/26/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB02012023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
488AC0D9-652F-4A8A-9B3D-6B78FC0C44BE 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11
Project Name:
U-Haul Moving and Storage
Test Location:
Building D foundation wall. 15 north of SE corner of
building.
Client:
Bateman-Hall
Admixtures:
MS AC 534, MA AE 90, MP
322
Ticket Number:
3156
Contractor:
Bateman-Hall
Supplier:
Walters
Mix Number:
W172F 350
Date:
1/25/2023
Cylinder Log #:
33
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
5.9
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
59
Ambient
Temperature
(°F):
13
Unit Weight
(PCF):
138.8
Tested By:
E. Vail
Date:
1/25/2023
Picked Up By:
E. Vail
Date:
1/26/2023
Time:
10:00 AM
Max, Min Temperature
80, 69
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 2/1/2023 4.000 12.56 44,750.0 3563 3,500.0 Type 2
Date:
02/01/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB02032023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
800297DE-D928-413A-84CC-3617DF408CFE 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Southern foundation wall
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
3005
Contractor:
BL Construction
Supplier:
Walters
Mix Number:
W-170FI U
Date:
1/6/2023
Cylinder Log #:
3
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.2
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
51
Ambient
Temperature
(°F):
35
Unit Weight
(PCF):
145.9
Tested By:
M.Mansfield
Date:
1/6/2023
Picked Up By:
M.Mansfield
Date:
1/7/2023
Time:
9:00 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/13/2023 12.56 42365 3373 3,500.00 Type 2
File name:
22247SB02032023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
800297DE-D928-413A-84CC-3617DF408CFE 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 2/3/2023 4.000 12.56 58,980.0 4696 3,500.0 Type 2
C 28 2/3/2023 4.000 12.56 57,185.0 4553 3,500.0 Type 2
D 28 2/3/2023 4.000 12.56 58,015.0 4619 3,500.0 Type 2
Second Break Average:
4623
Date:
02/07/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB02032023KD
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F9203C37-B125-48CD-A883-2B5FE67B4A1D 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
55.0
Project Name:
U-Haul Moving and Storage
Test Location:
Southern foundation walls
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
3009
Contractor:
BL Construction
Supplier:
Walters
Mix Number:
W-170FI U
Date:
1/6/2023
Cylinder Log #:
4
Field Test Results:
Set #:
2
Slump
Maximum
(in):
Entrained Air
(%):
1.5
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
58
Ambient
Temperature
(°F):
35
Unit Weight
(PCF):
145.4
Tested By:
M.Mansfield
Date:
1/6/2023
Picked Up By:
M.Mansfield
Date:
1/7/2023
Time:
9:00 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/13/2023 12.56 38020 3027 3,500.00 Type 1
File name:
22247SB02032023KD
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F9203C37-B125-48CD-A883-2B5FE67B4A1D 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 2/3/2023 4.000 12.56 51,045.0 4064 3,500.0 Type 4
C 28 2/3/2023 4.000 12.56 50,550.0 4025 3,500.0 Type 2
D 28 2/3/2023 4.000 12.56 50,970.0 4058 3,500.0 Type 2
Second Break Average:
4049
Date:
02/07/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB02082023LSH2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
CA00B49D-2174-4B92-BF57-B6AE9E735775 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
51.5
Project Name:
U-Haul Moving and Storage
Test Location:
Southwest corner of job
Client:
Bateman-Hall
Admixtures:
MP 355, MS AC 534
Ticket Number:
3029
Contractor:
Jerome Bowen
Supplier:
Walters Ready mix
Mix Number:
W-170FI U
Date:
1/11/2023
Cylinder Log #:
10
Field Test Results:
Set #:
2
Slump
Maximum
(in):
Entrained Air
(%):
1.0
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
62
Ambient
Temperature
(°F):
34
Unit Weight
(PCF):
146.9
Tested By:
M.Mansfield
Date:
1/11/2023
Picked Up By:
E. Vail
Date:
1/13/2023
Time:
11:30 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/18/2023 12.56 39605 3153 3,500.00 Type 1
File name:
22247SB02082023LSH2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
CA00B49D-2174-4B92-BF57-B6AE9E735775 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 2/8/2023 4.000 12.56 49,360.0 3930 3,500.0 Type 1
C 28 2/8/2023 4.000 12.56 49,290.0 3924 3,500.0 Type 4
D 28 2/8/2023 4.000 12.56 49,425.0 3935 3,500.0 Type 2
Second Break Average:
3930
Date:
02/09/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB02082023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
5B52C198-0991-4CC3-8914-BB3E6794A613 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11
Project Name:
U-Haul Moving and Storage
Test Location:
Southwest corner of job
Client:
Bateman-Hall
Admixtures:
MP 355, MS AC 534
Ticket Number:
3022
Contractor:
Jerome Bowen
Supplier:
Walters Ready mix
Mix Number:
W-170FI U
Date:
1/11/2023
Cylinder Log #:
9
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.3
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
61
Ambient
Temperature
(°F):
37
Unit Weight
(PCF):
146.3
Tested By:
M.Mansfield
Date:
1/11/2023
Picked Up By:
E. Vail
Date:
1/13/2023
Time:
11:15 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/18/2023 12.56 54000 4299 3,500.00 Type 1
File name:
22247SB02082023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
5B52C198-0991-4CC3-8914-BB3E6794A613 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 2/8/2023 4.000 12.56 64,655.0 5148 3,500.0 Type 2
C 28 2/8/2023 4.000 12.56 64,965.0 5172 3,500.0 Type 2
D 28 2/8/2023 4.000 12.56 64,095.0 5103 3,500.0 Type 3
Second Break Average:
5141
Date:
02/09/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB02102023KD
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
5250040F-D2E5-4F5E-9DAF-975C7A898B99 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
60 S of NW Corner Building B Lines: A-K
Client:
Bateman-Hall
Admixtures:
Super Plasticizer, MS AC
534, MP 322
Ticket Number:
3190
Contractor:
Bryan Landon
Supplier:
Walters
Mix Number:
W-170FI U
Date:
2/3/2023
Cylinder Log #:
45
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
2.0
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
56
Ambient
Temperature
(°F):
28
Unit Weight
(PCF):
142.7
Tested By:
Luke Hammar
Date:
2/3/2023
Picked Up By:
Luke Hammar
Date:
2/4/2023
Time:
7:18 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 2/10/2023 4.000 12.56 33,640.0 2678 3,500.0 Type 2
Date:
02/13/2023
Reviewed By:
Luke Hammar
Signature:
File Name
22247C02142023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
D9A943C3-9CC3-4AF0-BD00-BB41F230765A 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Ticket #:
3262
Project Name:
U-Haul Moving and Storage
Test Location:
Building B: Footings for southern wall
Client:
Bateman-Hall
Admixtures:
MSAC 534, MP 322
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bateman-Hall
Supplier:
Walters ready mix
Mix Number:
W-17OFI U
Date:
02/14/2023
Start Time
10:00 AM
End Time
01:15 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 11:30
AM
3262 Building
B:
Footings
for
southern
wall
25 146.3 1.5 N/A 60 8 Max
Observations/Remarks:
I arrived at the job site and looked over the rebar as well as the forms. The spacing was correct and so was the
ground clearance.
Once my inspection was completed, I returned to my vehicle to setup my equipment. I then waited for the truck
to show up.
The truck arrived around 11:15 AM and I was able to grab the batch ticket. After waiting for the driver to offload
about a yard and a half, I was able to grab a sample and begin testing.
I tested both air and slump, both of which were within spec. I reported to both the driver and the foreman.
I then casted strength specimens. Once completed, I placed them and began my cleanup.
File Name
22247C02142023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
D9A943C3-9CC3-4AF0-BD00-BB41F230765A 2
I observed the remainder of the pour and returned to my vehicle to fill out my report.
Tested By:
M.Mansfield
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
02/15/2023
Inspection Images
File name:
22247SB02162023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
05C56B76-C06C-4B98-A90E-39AB0BBE1D1D 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
33
Project Name:
U-Haul Moving and Storage
Test Location:
Building B footings, 40' north of SE corner.
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
3084
Contractor:
Bateman-Hall
Supplier:
Walters
Mix Number:
W-170FI U
Date:
1/19/2023
Cylinder Log #:
20
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.2
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
56
Ambient
Temperature
(°F):
23
Unit Weight
(PCF):
141.4
Tested By:
E. Vail
Date:
1/19/2023
Picked Up By:
Luke Hammar
Date:
1/20/2023
Time:
10:01 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/26/2023 12.56 31765 2529 3,500.00 Type 2
File name:
22247SB02162023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
05C56B76-C06C-4B98-A90E-39AB0BBE1D1D 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 2/16/2023 4.000 12.56 47,730.0 3800 3,500.0 Type 1
C 28 2/16/2023 4.000 12.56 48,985.0 3900 3,500.0 Type 3
D 28 2/16/2023 4.000 12.56 51,810.0 4125 3,500.0 Type 2
Second Break Average:
3942
Date:
02/16/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB02162023LSH2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
756CC2DF-9653-4606-88E5-3B6EF0232D9D 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
66
Project Name:
U-Haul Moving and Storage
Test Location:
Building B footings, 10' south of NE corner.
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
3088
Contractor:
Bateman-Hall
Supplier:
Walters
Mix Number:
W-170FI U
Date:
1/19/2023
Cylinder Log #:
21
Field Test Results:
Set #:
2
Slump
Maximum
(in):
Entrained Air
(%):
1.1
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
51
Ambient
Temperature
(°F):
23
Unit Weight
(PCF):
140.2
Tested By:
E. Vail
Date:
1/19/2023
Picked Up By:
Luke Hammar
Date:
1/20/2023
Time:
10:11 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 1/26/2023 12.56 32425 2582 3,500.00 Type 2
File name:
22247SB02162023LSH2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
756CC2DF-9653-4606-88E5-3B6EF0232D9D 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 2/16/2023 4.000 12.56 48,135.0 3832 3,500.0 Type 2
C 28 2/16/2023 4.000 12.56 46,925.0 3736 3,500.0 Type 2
D 28 2/16/2023 4.000 12.56 48,025.0 3824 3,500.0 Type 2
Second Break Average:
3797
Date:
02/16/2023
Reviewed By:
Luke Hammar
Signature:
File Name
22247C02162023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F7DB1F5D-279C-43FB-AFB3-0BCD709A5FA2 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Ticket #:
3278
Project Name:
U-Haul Moving and Storage
Test Location:
Building B, southern wall.
Client:
Bateman-Hall
Admixtures:
MA AE 90, MP 322
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bryan Landon Construction
Supplier:
Walters
Mix Number:
W172F 350
Date:
02/16/2023
Start Time
10:30 AM
End Time
01:15 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 11:30
AM
3278 Building
B,
southern
wall.
13 139.5 5.5 6 +- 1.5 65 8 Max
Observations/Remarks:
I arrived on site at 10:45 am and checked in with the Bryan Landon Construction foreman about where the best
place to set up would be that was out of the way.
After setting up my gear I went over to the wall forms to look over the rebar. I checked for correct size, spacing,
and to make sure no rebar was touching the forms. All appeared to be in good order.
Once the concrete arrived I was able to obtain a sample for testing. I tested for air, temp, and slump. All results
were within spec and reported to Walters and Bryan Landon Construction.
After testing, I made strength cylinders and then cleaned up my gear. Upon completion I was able to observe the
remainder of the pour. I did notice that mechanical vibration was being utilized to consolidate the concrete.
I left location at 12:45 pm.
File Name
22247C02162023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F7DB1F5D-279C-43FB-AFB3-0BCD709A5FA2 2
Tested By:
E. Vail
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
02/16/2023
Inspection Images
File Name
22247C02172023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
360110FA-6F59-4EF7-BBB1-D2CE5568B399 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
7.5
Ticket #:
3285
Project Name:
U-Haul Moving and Storage
Test Location:
Building B, south eastern most wall.
Client:
Bateman-Hall
Admixtures:
MA AE 90, MP 322
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bryan Landon Construction
Supplier:
Walters
Mix Number:
W172F 350
Date:
02/17/2023
Start Time
11:00 AM
End Time
01:15 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 11:45
AM
3285 Building
B, south
eastern
most wall.
14 138.2 6.8 6 +- 1.5 59 8 Max
Observations/Remarks:
I arrived on site at 11:15 am and checked in with the Bryan Landon Construction foreman about where the best
place to set up would be that was out of the way.
After setting up my gear I went over to the wall forms to look over the rebar. I checked for correct size, spacing,
and to make sure no rebar was touching the forms. All appeared to be in good order.
Once the concrete arrived I was able to obtain a sample for testing. I tested for air, temp, and slump. All results
were within spec and reported to Walters and Bryan Landon Construction.
After testing, I made strength cylinders and then cleaned up my gear. Upon completion I was able to observe the
remainder of the pour. I did notice that mechanical vibration was being utilized to consolidate the concrete.
I left location at 1:00 pm.
File Name
22247C02172023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
360110FA-6F59-4EF7-BBB1-D2CE5568B399 2
Tested By:
E. Vail
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
02/20/2023
Inspection Images
File name:
22247FB02212023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
9DA249E0-ECB4-417A-8E15-E085959682B7 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building B: Footings for southern wall
Client:
Bateman-Hall
Admixtures:
MSAC 534, MP 322
Ticket Number:
3262
Contractor:
Bryan Landon
Supplier:
Walters ready mix
Mix Number:
W-17OFI U
Date:
2/14/2023
Cylinder Log #:
56
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
1.5
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
60
Ambient
Temperature
(°F):
25
Unit Weight
(PCF):
146.3
Tested By:
M.Mansfield
Date:
2/14/2023
Picked Up By:
Luke Hammar
Date:
2/15/2023
Time:
9:22 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 2/21/2023 4.000 12.56 54,165.0 4313 3,500.0 Type 2
Date:
02/22/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB02222023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
E2E98429-CCD0-4CE5-870F-D27EE406DEC2 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11
Project Name:
U-Haul Moving and Storage
Test Location:
Building D foundation wall. 15 north of SE corner of
building.
Client:
Bateman-Hall
Admixtures:
MS AC 534, MA AE 90, MP
322
Ticket Number:
3156
Contractor:
Bateman-Hall
Supplier:
Walters
Mix Number:
W172F 350
Date:
1/25/2023
Cylinder Log #:
33
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
5.9
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
59
Ambient
Temperature
(°F):
13
Unit Weight
(PCF):
138.8
Tested By:
E. Vail
Date:
1/25/2023
Picked Up By:
E. Vail
Date:
1/26/2023
Time:
10:00 AM
Max, Min Temperature
80, 69
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 2/1/2023 12.56 44750 3563 3,500.00 Type 2
File name:
22247SB02222023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
E2E98429-CCD0-4CE5-870F-D27EE406DEC2 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 2/22/2023 4.000 12.56 58,780.0 4680 3,500.0 Type 2
C 28 2/22/2023 4.000 12.56 54,765.0 4360 3,500.0 Type 2
D 28 2/22/2023 4.000 12.56 55,985.0 4457 3,500.0 Type 4
Second Break Average:
4499
Date:
02/22/2023
Reviewed By:
Luke Hammar
Signature:
File Name
22247C02212023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
9425151A-E9F9-475C-8EE6-484988A0CA09 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Ticket #:
03308
Project Name:
U-Haul Moving and Storage
Test Location:
East of building B
Client:
Bateman-Hall
Admixtures:
MS AC534, MP 322
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bryan Landon
Supplier:
Walters
Mix Number:
W-170FI U
Date:
02/21/2023
Start Time
10:45 AM
End Time
01:00 PM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 12:15
PM
03308 East of
building B
37 146.9 1.5 N/A 62 8 Max
Observations/Remarks:
I arrived at the job and spoke with the foreman. We discussed the pour and I went and performed a rebar
inspection. Once completed I returned to my vehicle to setup my equipment.
After setting up I returned to the pour site and waited for the truck to arrive.
The truck arrived just after 12, and I was able to grab my ticket. After waiting the proper amount of time I
grabbed a sample and began testing. I tested both air and slump, and found them to be within spec. I reported
the results to the driver and the foreman.
I observed the remainder of the pour. Once completed I returned to fill out my report.
Tested By:
M.Mansfield
Signature:
Reviewed By:
Luke Hammar
Signature:
File Name
22247C02212023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
9425151A-E9F9-475C-8EE6-484988A0CA09 2
Date:
02/23/2023
Inspection Images
File name:
22247FB03032023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
70CEF8B1-031E-467F-BF6A-EB3A391444B9 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
8.8
Project Name:
U-Haul Moving and Storage
Test Location:
Loading dock foundation walls
Client:
Bateman-Hall
Admixtures:
X-Seed, MS AC 534, MP
322
Ticket Number:
3333
Contractor:
Bryan Landon
Supplier:
Walters ready mix
Mix Number:
W172F 350
Date:
2/24/2023
Cylinder Log #:
73
Field Test Results:
Set #:
1
Entrained Air
(%):
7.5
Concrete
Temperature
(°F):
58
Ambient
Temperature
(°F):
27
Unit Weight
(PCF):
137.8
Tested By:
M.Mansfield
Date:
2/24/2023
Picked Up By:
K. Drake
Date:
2/25/2023
Time:
11:44 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 3/3/2023 4.000 12.56 48,735.0 3880 3,500.0 Type 2
Date:
03/03/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB02232023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
18D89B9E-943F-47C1-B20C-45EC7EC8D538 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building B, south eastern most wall.
Client:
Bateman-Hall
Admixtures:
MA AE 90, MP 322
Ticket Number:
3278
Contractor:
Bryan Landon Construction
Supplier:
Walters
Mix Number:
W172F 350
Date:
2/16/2023
Cylinder Log #:
59
Field Test Results:
Set #:
1
Slump
Maximum
(in):
Entrained Air
(%):
5.5
Entrained Air
Spec. (%):
Concrete
Temperature
(°F):
65
Ambient
Temperature
(°F):
13
Unit Weight
(PCF):
139.5
Tested By:
E. Vail
Date:
2/16/2023
Picked Up By:
E. Vail
Date:
2/17/2023
Time:
1:45 PM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 2/23/2023 4.000 12.56 60,345.0 4805 3,500.0 Type 1
Date:
02/24/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB03142023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F6D29BD9-683E-4EAD-A4AE-D04B43761897 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building B: Footings for southern wall
Client:
Bateman-Hall
Admixtures:
MSAC 534, MP 322
Contractor:
Bryan Landon
Supplier:
Walters ready mix
Mix Number:
W-17OFI U
Date:
2/14/2023
Cylinder Log #:
56
Field Test Results:
Set #:
1
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
60
Ambient
Temperature
(°F):
25
Unit Weight
(PCF):
146.3
Tested By:
M.Mansfield
Date:
2/14/2023
Picked Up By:
Luke Hammar
Date:
2/15/2023
Time:
9:22 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 2/21/2023 12.56 54165 4313 3,500.00 Type 2
File name:
22247SB03142023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F6D29BD9-683E-4EAD-A4AE-D04B43761897 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 3/14/2023 4.000 12.56 65,130.0 5186 3,500.0 Type 2
C 28 3/14/2023 4.000 12.56 65,185.0 5190 3,500.0 Type 3
D 28 3/14/2023 4.000 12.56 67,305.0 5359 3,500.0 Type 1
Second Break Average:
5245
Date:
03/14/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247CB03172023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
9ACAAACF-711F-4BFE-B0B6-5C398F1ECAAB 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
7.5
Project Name:
U-Haul Moving and Storage
Test Location:
Building B, south eastern most wall.
Client:
Bateman-Hall
Admixtures:
MA AE 90, MP 322
Contractor:
Bryan Landon Construction
Supplier:
Walters
Mix Number:
W172F 350
Date:
2/17/2023
Cylinder Log #:
61
Field Test Results:
Set #:
1
Entrained Air
(%):
6.8
Concrete
Temperature
(°F):
59
Ambient
Temperature
(°F):
14
Unit Weight
(PCF):
138.2
Tested By:
E. Vail
Date:
2/17/2023
Picked Up By:
Luke Hammar
Date:
2/18/2023
Time:
11:03 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 2/24/2023 12.57 42395 3373 3,500.00 Type 2
File name:
22247CB03172023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
9ACAAACF-711F-4BFE-B0B6-5C398F1ECAAB 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 3/17/2023 4.000 12.57 55,745.0 4435 3,500.0 Type 2
C 28 3/17/2023 4.000 12.57 55,705.0 4432 3,500.0 Type 2
D 28 3/17/2023 4.000 12.57 55,290.0 4399 3,500.0 Type 2
Second Break Average:
4422
Date:
03/20/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247CB03162023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8296565D-5A89-4B4A-8B25-1CF7712F80AE 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11
Project Name:
U-Haul Moving and Storage
Test Location:
Building B, south eastern most wall.
Client:
Bateman-Hall
Admixtures:
MA AE 90, MP 322
Contractor:
Bryan Landon Construction
Supplier:
Walters
Mix Number:
W172F 350
Date:
2/16/2023
Cylinder Log #:
59
Field Test Results:
Set #:
1
Entrained Air
(%):
5.5
Concrete
Temperature
(°F):
65
Ambient
Temperature
(°F):
13
Unit Weight
(PCF):
139.5
Tested By:
E. Vail
Date:
2/16/2023
Picked Up By:
E. Vail
Date:
2/17/2023
Time:
1:45 PM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 2/23/2023 12.57 60345 4801 3,500.00 Type 1
File name:
22247CB03162023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8296565D-5A89-4B4A-8B25-1CF7712F80AE 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 3/16/2023 4.000 12.57 68,545.0 5453 3,500.0 Type 2
C 28 3/16/2023 4.000 12.57 67,930.0 5404 3,500.0 Type 2
D 28 3/16/2023 4.000 12.57 70,245.0 5588 3,500.0 Type 2
Second Break Average:
5482
Date:
03/20/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB03242023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
859E450C-D5F6-4E26-9F14-FA72828E29E7 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
8.8
Project Name:
U-Haul Moving and Storage
Test Location:
Loading dock foundation walls
Client:
Bateman-Hall
Admixtures:
X-Seed, MS AC 534, MP
322
Contractor:
Bryan Landon
Supplier:
Walters ready mix
Mix Number:
W172F 350
Date:
2/24/2023
Cylinder Log #:
73
Field Test Results:
Set #:
1
Entrained Air
(%):
7.5
Concrete
Temperature
(°F):
58
Ambient
Temperature
(°F):
27
Unit Weight
(PCF):
137.8
Tested By:
M.Mansfield
Date:
2/24/2023
Picked Up By:
K. Drake
Date:
2/25/2023
Time:
11:44 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 3/3/2023 12.57 48735 3877 3,500.00 Type 2
File name:
22247SB03242023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
859E450C-D5F6-4E26-9F14-FA72828E29E7 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 3/24/2023 4.000 12.57 62,030.0 4935 3,500.0 Type 4
C 28 3/24/2023 4.000 12.57 64,670.0 5145 3,500.0 Type 2
D 28 3/24/2023 4.000 12.57 63,275.0 5034 3,500.0 Type 2
Second Break Average:
5038
Date:
03/24/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247CFB04172023
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
3B21445A-02B8-4270-9E7F-25A2E2E88A2C 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
3.5
Project Name:
U-Haul Moving and Storage
Test Location:
K Line: 3-4
Client:
Bateman-Hall
Admixtures:
MA AE 90, MP 322
Ticket Number:
3645
Contractor:
Bryan Landon Construction
Supplier:
Walters
Mix Number:
W172F 350
Date:
4/10/2023
Cylinder Log #:
125
Field Test Results:
Set #:
1
Entrained Air
(%):
6.6
Concrete
Temperature
(°F):
68
Ambient
Temperature
(°F):
61
Unit Weight
(PCF):
139.0
Tested By:
E. Vail
Date:
4/10/2023
Picked Up By:
E. Vail
Date:
4/11/2023
Time:
4:15 PM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 4/17/2023 4.000 12.56 45,555.0 3627 3,500.0 Type 1
Date:
04/17/2023
Reviewed By:
Luke Hammar
Signature:
File Name
22247C04282023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
A9C15922-AEC2-4AA2-BC20-2218FB5D2B3E 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10.0
Ticket #:
04042
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Required 28 day Strength
(psi):
4,000.0
Contractor:
Bryan Landon
Supplier:
Walter’s Ready Mix
Mix Number:
W-172FI U
Date:
04/28/2023
Start Time
04:57 AM
End Time
11:00 AM
Current Weather Conditions:
Sunny/Clear
Wind:
Calm
Testing:
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
1 10.0 04:50 AM Building A
slab
27 36.100 145.0 69 1.5 N/A 7 6 Max
2 50.0 05:25 AM Building A
slab
28 36.000 144.6 68 1.0 N/A 7 6 Max
3 110.0 06:00 AM Building A
slab
28 36.240 145.5 67 1.5 N/A 7 6 Max
4 150.0 06:20 AM Building A
slab
28 36.100 145.0 67 1.5 N/A 7 6 Max
5 200.0 06:50 AM Building A
slab
29 36.300 145.8 66 1.5 N/A 7 6 Max
6 250.0 07:35 AM Building A
slab
30 36.240 145.5 65 1.5 N/A 7 6 Max
7 300.0 08:10 AM Building A
slab
33 36.400 146.2 64 1.6 N/A 5.5 6 Max
8 350.0 08:35 AM Building A 36 36.240 145.5 65 1.7 N/A 5 6 Max
File Name
22247C04282023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
A9C15922-AEC2-4AA2-BC20-2218FB5D2B3E 2
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
slab
9 410.0 09:15 AM Building A
slab
40 36.300 145.8 68 1.5 N/A 5 6 Max
10 450.0 09:40 AM Building A
slab
41 36.260 145.6 67 1.6 N/A 5 6 Max
11 500.0 10:10 AM Building A
slab
41 36.300 145.8 67 1.6 N/A 5 6 Max
Observations/Remarks:
I arrived on site at 4:30 AM, contractor was on site setting up their equipment. I walked around checking on the
forms to make sure the rebar was within spec. The first truck arrived around 4:50-5:00 AM. We grabbed our first
sample around 5:10 AM. We tested every 50-60 yards of the pour, and did a total of 11 tests.
We finished testing and started to clean up around 10:15-10:20 am.
Tested By:
B. Choffin
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
04/28/2023
Inspection Images
File Name
22247C04282023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
A9C15922-AEC2-4AA2-BC20-2218FB5D2B3E 3
File Name
22247C05032023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1CCDC3A3-16F7-4071-99F1-1859289FF501 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
20.0
Ticket #:
04198
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Na
Required 28 day Strength
(psi):
4,000.0
Contractor:
Bryan Landon
Supplier:
Walter’s Ready Mix
Mix Number:
N-172F1 U
Date:
05/03/2023
Start Time
04:30 AM
End Time
09:45 AM
Current Weather Conditions:
Partly Cloudy
Wind:
Calm
Testing:
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
1 20.0 05:20 AM Building A
slab
39 36.460 146.4 74 1.5 N/A 7 6 Max
2 60.0 05:40 AM Building A
slab
39 36.520 146.7 70 1.7 N/A 7 6 Max
3 110.0 06:30 AM Building A
slab
40 36.400 146.2 69 1.6 N/A 6.5 6 Max
4 160.0 06:45 AM Building A
slab
41 36.400 146.2 68 1.7 N/A 6.5 6 Max
5 210.0 07:10 AM Building A
slab
44 36.400 146.2 71 1.9 N/A 5.5 6 Max
6 260.0 07:55 AM Building A
slab
47 36.500 146.6 72 1.8 N/A 6 6 Max
7 310.0 08:40 AM Building A
slab
53 36.280 145.7 73 1.8 N/A 5.5 6 Max
File Name
22247C05032023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1CCDC3A3-16F7-4071-99F1-1859289FF501 2
Observations/Remarks:
I arrived on site around 4:30 am. I got out of my vehicle to go inspect the rebar placements and found it to be
within general conformance to project guidelines. I then proceeded to set up my testing equipment for the day.
The first truck arrived around 5 am. I got my first sample around 5:10-5:15 AM. All tests resulted to be within
spec. And were reported. I did a total of 7 tests.
I observed the duration of the pour and wrote this report.
Tested By:
B. Choffin
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
05/03/2023
Inspection Images
File Name
22247C05032023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
1CCDC3A3-16F7-4071-99F1-1859289FF501 3
File name:
22247FB05052023LSH9
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C91B1FB1-8919-435D-87D4-561828391395 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
410
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Ticket Number:
4084
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
161
Field Test Results:
Set #:
9
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
68
Ambient
Temperature
(°F):
40
Unit Weight
(PCF):
145.8
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
12:40 PM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 4.000 12.56 52,450.0 4176 4,000.0 Type 2
Date:
05/05/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05052023LSH8
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
ED74B6DB-6739-496E-A56B-8EE5414F53B9 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
350
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Ticket Number:
4078
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
160
Field Test Results:
Set #:
8
Entrained Air
(%):
1.7
Concrete
Temperature
(°F):
65
Ambient
Temperature
(°F):
36
Unit Weight
(PCF):
145.5
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
12:34 PM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 4.000 12.56 52,130.0 4150 4,000.0 Type 2
Date:
05/05/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05052023LSH7
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
6D172B57-1C94-4A29-BCD0-012AAE37616B 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
300
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Ticket Number:
4073
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
159
Field Test Results:
Set #:
7
Entrained Air
(%):
1.6
Concrete
Temperature
(°F):
64
Ambient
Temperature
(°F):
33
Unit Weight
(PCF):
146.2
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
12:27 PM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 4.000 12.56 56,270.0 4480 4,000.0 Type 2
Date:
05/05/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05052023LSH6
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
08737B9C-EEB0-4256-BA86-90DA5869214A 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
250
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Ticket Number:
4066
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
158
Field Test Results:
Set #:
6
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
65
Ambient
Temperature
(°F):
30
Unit Weight
(PCF):
145.5
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
12:21 PM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 4.000 12.56 52,655.0 4192 4,000.0 Type 3
Date:
05/05/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05052023LSH1
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
A9486F6F-9AFC-4D18-A926-B760B1AC5395 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Ticket Number:
4042
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
153
Field Test Results:
Set #:
1
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
69
Ambient
Temperature
(°F):
27
Unit Weight
(PCF):
145
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
11:42 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 4.000 12.56 54,250.0 4319 4,000.0 Type 1
Date:
05/05/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB05082023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
386EEC4D-3859-45F3-9182-F57612FD8002 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
3.5
Project Name:
U-Haul Moving and Storage
Test Location:
K Line: 3-4
Client:
Bateman-Hall
Admixtures:
MA AE 90, MP 322
Contractor:
Bryan Landon Construction
Supplier:
Walters
Mix Number:
W172F 350
Date:
4/10/2023
Cylinder Log #:
125
Field Test Results:
Set #:
1
Entrained Air
(%):
6.6
Concrete
Temperature
(°F):
68
Ambient
Temperature
(°F):
61
Unit Weight
(PCF):
139
Tested By:
E. Vail
Date:
4/10/2023
Picked Up By:
E. Vail
Date:
4/11/2023
Time:
4:15 PM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 4/17/2023 12.57 45555 3624 3,500.00 Type 1
File name:
22247SB05082023EV
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
386EEC4D-3859-45F3-9182-F57612FD8002 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/8/2023 4.000 12.57 59,005.0 4694 3,500.0 Type 2
C 28 5/8/2023 4.000 12.57 59,220.0 4711 3,500.0 Type 4
D 28 5/8/2023 4.000 12.57 59,950.0 4769 3,500.0 Type 2
Second Break Average:
4725
Date:
05/08/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05102023LSH6
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
80C3D6F8-2F21-4675-8163-F68D4DD817C9 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
260
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Ticket Number:
4223
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
175
Field Test Results:
Set #:
6
Entrained Air
(%):
1.8
Concrete
Temperature
(°F):
72
Ambient
Temperature
(°F):
47
Unit Weight
(PCF):
146.6
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
10:57 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 4.000 12.56 67,390.0 5365 4,000.0 Type 1
Date:
05/10/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05102023LSH5
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8A6A3732-F228-442C-B116-58F09BAFAF9C 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
210
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Ticket Number:
4217
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
174
Field Test Results:
Set #:
5
Entrained Air
(%):
1.9
Concrete
Temperature
(°F):
71
Ambient
Temperature
(°F):
44
Unit Weight
(PCF):
146.2
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
10:49 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 4.000 12.56 66,925.0 5328 4,000.0 Type 2
Date:
05/10/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05102023LSH4
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
FED5F648-4992-4860-8788-E0C175BEB6AE 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
160
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Ticket Number:
4212
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
173
Field Test Results:
Set #:
4
Entrained Air
(%):
1.7
Concrete
Temperature
(°F):
68
Ambient
Temperature
(°F):
41
Unit Weight
(PCF):
146.2
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
11:17 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 4.000 12.56 62,890.0 5007 4,000.0 Type 4
Date:
05/10/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05102023LSH3
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8FD12EEC-167D-4F01-875B-B049B113E9B4 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
110
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Ticket Number:
4207
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
172
Field Test Results:
Set #:
3
Entrained Air
(%):
1.6
Concrete
Temperature
(°F):
69
Ambient
Temperature
(°F):
40
Unit Weight
(PCF):
146.2
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
11:25 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 4.000 12.56 57,805.0 4602 4,000.0 Type 3
Date:
05/10/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05102023LSH2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
434DEA5C-6BAD-4A9C-AA15-20A295D14516 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
60
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Ticket Number:
4202
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
171
Field Test Results:
Set #:
2
Entrained Air
(%):
1.7
Concrete
Temperature
(°F):
70
Ambient
Temperature
(°F):
39
Unit Weight
(PCF):
146.7
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
11:32 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 4.000 12.56 58,215.0 4635 4,000.0 Type 2
Date:
05/10/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05102023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
305EEA74-9DF0-4DE4-8EFA-3CFB6557C839 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
20
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Ticket Number:
4198
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
170
Field Test Results:
Set #:
1
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
74
Ambient
Temperature
(°F):
39
Unit Weight
(PCF):
146.4
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
11:40 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 4.000 12.56 60,580.0 4823 4,000.0 Type 1
Date:
05/10/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB05102023CH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
D7656983-9903-4B9C-A05F-E1ABF73C75B0 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
310.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Ticket Number:
4228
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
176
Field Test Results:
Set #:
7
Entrained Air
(%):
1.8
Concrete
Temperature
(°F):
73
Ambient
Temperature
(°F):
53
Unit Weight
(PCF):
145.7
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
11:08 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 4.000 12.56 53,725.0 4277 4,000.0 Type 6
Date:
05/10/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB03032023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
91C5EB5B-27A8-4D00-874B-8FD7FCA39278 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
11
Project Name:
U-Haul Moving and Storage
Test Location:
60 S of NW Corner Building B Lines: A-K
Client:
Bateman-Hall
Admixtures:
Super Plasticizer, MS AC
534, MP 322
Contractor:
Bryan Landon
Supplier:
Walters
Mix Number:
W-170FI U
Date:
2/3/2023
Cylinder Log #:
45
Field Test Results:
Set #:
1
Entrained Air
(%):
2.0
Concrete
Temperature
(°F):
56
Ambient
Temperature
(°F):
28
Unit Weight
(PCF):
142.7
Tested By:
Luke Hammar
Date:
2/3/2023
Picked Up By:
Luke Hammar
Date:
2/4/2023
Time:
7:18 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 2/10/2023 12.56 33640 2678 3,500.00 Type 2
File name:
22247SB03032023LSH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
91C5EB5B-27A8-4D00-874B-8FD7FCA39278 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 3/3/2023 4.000 12.56 47,115.0 3751 3,500.0 Type 1
C 28 3/3/2023 4.000 12.56 47,720.0 3799 3,500.0 Type 2
D 28 3/3/2023 4.000 12.56 48,330.0 3848 3,500.0 Type 3
Second Break Average:
3799
Date:
03/03/2023
Reviewed By:
Luke Hammar
Signature:
File Name
22247C02242023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C5A02814-5AAC-4AA6-9828-03428D2B9896 1
4103 E 605 N Suite 1 Rigby, ID 83442 208.881.0081 www.connectengr.com
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
8.8
Ticket #:
3333
Project Name:
U-Haul Moving and Storage
Test Location:
Loading dock foundation walls
Client:
Bateman-Hall
Admixtures:
X-Seed, MS AC 534, MP
322
Required 28 day Strength
(psi):
3,500.0
Contractor:
Bateman-Hall
Supplier:
Walters ready mix
Mix Number:
W172F 350
Date:
02/24/2023
Start Time
09:00 AM
End Time
11:00 AM
Testing:
Set #:Time
Tested:
Ticket #:Test
Location:
Ambient
Temp.
(°F):
Unit Weight
(PCF):
Entrained
Air (%):
Entrained
Air
Spec.
(%):
Concrete
Temp.
(°F):
Slump
(in):
Slump
Spec.
(in):
1 10:30
AM
3333 Loading
dock
foundation
walls
27 137.8 7.5 6 +- 1.5 58 8 Max
Observations/Remarks:
I arrived at the job site around 9:15 and looked over the rebar. It looked good for the most part, I spoke with
the crew about some question areas. And the crew solved the issues.
I returned to my vehicle to setup my equipment.
The first truck arrived around 10:20, I was able to grab a ticket and wait to grab a sample. Once I received a
sample, I returned to my work area to begin my testing. I tested both air and slump, both of which were within
spec.
I reported the results to the driver.
I cleaned my equipment and left the job site.
Tested By:
M.Mansfield
Reviewed By:
Luke Hammar
File Name
22247C02242023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C5A02814-5AAC-4AA6-9828-03428D2B9896 2
Signature:Signature:
Date:
02/27/2023
Inspection Images
File Name
22247C02242023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C5A02814-5AAC-4AA6-9828-03428D2B9896 3
File name:
22247SB05262023EV1
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F38127B3-EFD0-4250-9417-CF54B0F3BE9F 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
350
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
160
Field Test Results:
Set #:
8
Entrained Air
(%):
1.7
Concrete
Temperature
(°F):
65
Ambient
Temperature
(°F):
36
Unit Weight
(PCF):
145.5
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
12:34 PM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 12.56 52130 4150 4,000.00 Type 2
File name:
22247SB05262023EV1
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
F38127B3-EFD0-4250-9417-CF54B0F3BE9F 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/26/2023 4.000 12.56 65,875.0 5245 4,000.0 Type 2
C 28 5/26/2023 4.000 12.56 66,450.0 5291 4,000.0 Type 1
D 28 5/26/2023 4.000 12.56 64,310.0 5120 4,000.0 Type 1
Second Break Average:
5219
Date:
05/26/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB05262023EV2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
CC453F13-38DA-4B46-B963-1FF9FF776CBA 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
410
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
161
Field Test Results:
Set #:
9
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
68
Ambient
Temperature
(°F):
40
Unit Weight
(PCF):
145.8
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
12:40 PM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 12.56 52450 4176 4,000.00 Type 2
File name:
22247SB05262023EV2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
CC453F13-38DA-4B46-B963-1FF9FF776CBA 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/26/2023 4.000 12.56 66,865.0 5324 4,000.0 Type 1
C 28 5/26/2023 4.000 12.56 68,350.0 5442 4,000.0 Type 3
D 28 5/26/2023 4.000 12.56 67,030.0 5337 4,000.0 Type 2
Second Break Average:
5368
Date:
05/26/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB05262023EV4
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8336D13C-7D34-4AEC-AF91-4361130E2262 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
500
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
163
Field Test Results:
Set #:
11
Entrained Air
(%):
1.6
Concrete
Temperature
(°F):
67
Ambient
Temperature
(°F):
41
Unit Weight
(PCF):
145.8
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
12:54 PM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 12.56 54590 4346 4,000.00 Type 2
File name:
22247SB05262023EV4
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8336D13C-7D34-4AEC-AF91-4361130E2262 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/26/2023 4.000 12.56 70,935.0 5648 4,000.0 Type 2
C 28 5/26/2023 4.000 12.56 74,125.0 5902 4,000.0 Type 1
D 28 5/26/2023 4.000 12.56 72,840.0 5799 4,000.0 Type 5
Second Break Average:
5783
Date:
05/26/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB05262023EV5
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
CE0A5251-4986-40B3-81B0-B4E28F4D585A 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
250
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
158
Field Test Results:
Set #:
6
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
65
Ambient
Temperature
(°F):
30
Unit Weight
(PCF):
145.5
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
12:21 PM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 12.56 52655 4192 4,000.00 Type 3
File name:
22247SB05262023EV5
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
CE0A5251-4986-40B3-81B0-B4E28F4D585A 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/26/2023 4.000 12.56 68,230.0 5432 4,000.0 Type 6
C 28 5/26/2023 4.000 12.56 66,590.0 5302 4,000.0 Type 2
D 28 5/26/2023 4.000 12.56 67,960.0 5411 4,000.0 Type 1
Second Break Average:
5382
Date:
05/26/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB05262023EV6
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
659E5B4C-D554-45E7-9FF2-0421A4B0CD14 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
200
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
157
Field Test Results:
Set #:
5
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
66
Ambient
Temperature
(°F):
29
Unit Weight
(PCF):
145.8
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
12:15 PM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 12.56 51345 4088 4,000.00 Type 2
File name:
22247SB05262023EV6
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
659E5B4C-D554-45E7-9FF2-0421A4B0CD14 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/26/2023 4.000 12.56 68,105.0 5422 4,000.0 Type 2
C 28 5/26/2023 4.000 12.56 68,640.0 5465 4,000.0 Type 1
D 28 5/26/2023 4.000 12.56 68,605.0 5462 4,000.0 Type 2
Second Break Average:
5450
Date:
05/26/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB05262023EV10
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
730D48A1-705A-43E1-8A72-7706B5D7AF65 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
153
Field Test Results:
Set #:
1
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
69
Ambient
Temperature
(°F):
27
Unit Weight
(PCF):
145
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
11:42 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 12.56 54250 4319 4,000.00 Type 1
File name:
22247SB05262023EV10
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
730D48A1-705A-43E1-8A72-7706B5D7AF65 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/26/2023 4.000 12.56 73,050.0 5816 4,000.0 Type 4
C 28 5/26/2023 4.000 12.56 70,110.0 5582 4,000.0 Type 1
D 28 5/26/2023 4.000 12.56 68,080.0 5420 4,000.0 Type 1
Second Break Average:
5606
Date:
05/26/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB05262023EV11
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
7C4B4E5B-6D92-46DD-A0DC-CA4577A7BC43 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
300
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
Super Plastisizer, 2% NC
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
W-172FI U
Date:
4/28/2023
Cylinder Log #:
159
Field Test Results:
Set #:
7
Entrained Air
(%):
1.6
Concrete
Temperature
(°F):
64
Ambient
Temperature
(°F):
33
Unit Weight
(PCF):
146.2
Tested By:
B. Choffin
Date:
4/28/2023
Picked Up By:
Luke Hammar
Date:
4/29/2023
Time:
12:27 PM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/5/2023 12.56 56270 4480 4,000.00 Type 2
File name:
22247SB05262023EV11
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
7C4B4E5B-6D92-46DD-A0DC-CA4577A7BC43 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/26/2023 4.000 12.56 78,065.0 6215 4,000.0 Type 5
C 28 5/26/2023 4.000 12.56 75,970.0 6049 4,000.0 Type 1
D 28 5/26/2023 4.000 12.56 73,675.0 5866 4,000.0 Type 5
Second Break Average:
6043
Date:
05/26/2023
Reviewed By:
Luke Hammar
Signature:
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C1156B4A-7177-4B7A-A17C-0EAD4BFA1CCB 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10.0
Ticket #:
05029
Project Name:
U-Haul Moving and Storage
Test Location:
Building A Gridline E:9
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322, MA AE
90
Required 28 day Strength
(psi):
3,500.0
Supplier:
Walters Ready Mix, Inc.
Mix Number:
142-3500
Date:
05/31/2023
Start Time
04:30 AM
End Time
08:45 AM
Testing:
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
1 10.0 05:15 AM Building A
Gridline E:
9
46 35.100 141.0 69 5.0 6 +-
1.5
6.5 8 Max
2 60.0 07:15 AM Building A
Gridline D:
14
50 35.200 141.4 68 5.0 6 +-
1.5
7 8 Max
Observations/Remarks:
I arrived on site at approximately 4:55 AM and proceeded to immediately set up my testing equipment in
preparation for testing. Shortly after I inspected the rebar placement inside of the forms and found them to be
within acceptable specifications.
When the first truck arrived on site at approximately 5:00 AM I proceeded to acquire a sample and test. The
tests were acceptable and passed within the given parameters. However when testing the truck for 50-60 yards I
found the air quality to be lower than passing. By the time the test was finished, the concrete had all been
poured and the truck had left. I then tested the truck with 80-90 yards and found all tests to be acceptable and
within the given parameters.
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C1156B4A-7177-4B7A-A17C-0EAD4BFA1CCB 2
I then cleaned my testing equipment and observed that the contractor used a mechanical vibration device to
properly displace the material. I observed that an employee of the contractor stayed behind after other
employees had moved on to ensure that the concrete was all finished correctly.
Tested By:
Michael Hammar
Signature:
Reviewed By:
E. Vail
Signature:
Date:
05/31/2023
Inspection Images
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C1156B4A-7177-4B7A-A17C-0EAD4BFA1CCB 3
File name:
22247SB05312023JPC7
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
96156F20-667B-497F-891F-E7C940906EA0 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
210.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
174
Field Test Results:
Set #:
5
Entrained Air
(%):
1.9
Concrete
Temperature
(°F):
71
Ambient
Temperature
(°F):
44
Unit Weight
(PCF):
146.2
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
10:49 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 12.56 66925 5328 4,000.00 Type 2
File name:
22247SB05312023JPC7
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
96156F20-667B-497F-891F-E7C940906EA0 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/31/2023 4.000 12.56 83,805.0 6672 4,000.0 Type 1
C 28 5/31/2023 4.000 12.56 77,995.0 6210 4,000.0 Type 1
D 28 5/31/2023 4.000 12.56 83,710.0 6665 4,000.0 Type 1
Second Break Average:
6515
Date:
05/31/2023
Reviewed By:
E. Vail
Signature:
File name:
22247SB05312023JPC6
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
12A771D7-BD4C-43C4-9E01-03C5B84A39D9 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
260.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
175
Field Test Results:
Set #:
6
Entrained Air
(%):
1.8
Concrete
Temperature
(°F):
72
Ambient
Temperature
(°F):
47
Unit Weight
(PCF):
146.6
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
10:57 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 12.56 67390 5365 4,000.00 Type 1
File name:
22247SB05312023JPC6
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
12A771D7-BD4C-43C4-9E01-03C5B84A39D9 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/31/2023 4.000 12.56 85,680.0 6822 4,000.0 Type 1
C 28 5/31/2023 4.000 12.56 82,425.0 6563 4,000.0 Type 1
D 28 5/31/2023 4.000 12.56 85,920.0 6841 4,000.0 Type 1
Second Break Average:
6742
Date:
05/31/2023
Reviewed By:
E. Vail
Signature:
File name:
22247SB05312023JPC5
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
2C3D4CF3-091B-4730-BA55-EDD1C4D0C39B 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
310.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
176
Field Test Results:
Set #:
7
Entrained Air
(%):
1.8
Concrete
Temperature
(°F):
73
Ambient
Temperature
(°F):
53
Unit Weight
(PCF):
145.7
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
11:08 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 12.56 53725 4277 4,000.00 Type 6
File name:
22247SB05312023JPC5
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
2C3D4CF3-091B-4730-BA55-EDD1C4D0C39B 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/31/2023 4.000 12.56 72,305.0 5757 4,000.0 Type 1
C 28 5/31/2023 4.000 12.56 70,770.0 5635 4,000.0 Type 1
D 28 5/31/2023 4.000 12.56 68,645.0 5465 4,000.0 Type 3
Second Break Average:
5619
Date:
05/31/2023
Reviewed By:
E. Vail
Signature:
File name:
22247SB05312023JPC3
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
7521C3D2-5D6D-439E-B99F-9800966E605E 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
110.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
172
Field Test Results:
Set #:
3
Entrained Air
(%):
1.6
Concrete
Temperature
(°F):
69
Ambient
Temperature
(°F):
40
Unit Weight
(PCF):
146.2
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
11:25 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 12.56 57805 4602 4,000.00 Type 3
File name:
22247SB05312023JPC3
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
7521C3D2-5D6D-439E-B99F-9800966E605E 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/31/2023 4.000 12.56 76,825.0 6117 4,000.0 Type 3
C 28 5/31/2023 4.000 12.56 75,520.0 6013 4,000.0 Type 3
D 28 5/31/2023 4.000 12.56 73,680.0 5866 4,000.0 Type 3
Second Break Average:
5999
Date:
05/31/2023
Reviewed By:
E. Vail
Signature:
File name:
22247SB05312023JPC2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C56EE552-F357-4CA0-8FDC-B375606E7809 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
60.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
171
Field Test Results:
Set #:
2
Entrained Air
(%):
1.7
Concrete
Temperature
(°F):
70
Ambient
Temperature
(°F):
39
Unit Weight
(PCF):
146.7
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
11:32 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 12.56 58215 4635 4,000.00 Type 2
File name:
22247SB05312023JPC2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C56EE552-F357-4CA0-8FDC-B375606E7809 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/31/2023 4.000 12.56 77,840.0 6197 4,000.0 Type 1
C 28 5/31/2023 4.000 12.56 78,605.0 6258 4,000.0 Type 1
D 28 5/31/2023 4.000 12.56 77,360.0 6159 4,000.0 Type 1
Second Break Average:
6204
Date:
05/31/2023
Reviewed By:
E. Vail
Signature:
File name:
22247SB05312023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
83D10B52-3890-4624-9EAF-E8D835DD72C3 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
20.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab
Client:
Bateman-Hall
Admixtures:
N/A
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix
Mix Number:
N-172F1 U
Date:
5/3/2023
Cylinder Log #:
170
Field Test Results:
Set #:
1
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
74
Ambient
Temperature
(°F):
39
Unit Weight
(PCF):
146.4
Tested By:
B. Choffin
Date:
5/3/2023
Picked Up By:
B. Choffin
Date:
5/4/2023
Time:
11:40 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 5/10/2023 12.56 60580 4823 4,000.00 Type 1
File name:
22247SB05312023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
83D10B52-3890-4624-9EAF-E8D835DD72C3 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 5/31/2023 4.000 12.56 75,595.0 6019 4,000.0 Type 3
C 28 5/31/2023 4.000 12.56 74,125.0 5902 4,000.0 Type 1
D 28 5/31/2023 4.000 12.56 73,630.0 5862 4,000.0 Type 3
Second Break Average:
5928
Date:
05/31/2023
Reviewed By:
E. Vail
Signature:
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8EE06C7F-445C-445F-80EB-6527F5406064 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
7.2
Ticket #:
05076
Project Name:
U-Haul Moving and Storage
Test Location:
Building A slab approx. A-17
Client:
Bateman-Hall
Admixtures:
MS-AC-534, MP-322
Required 28 day Strength
(psi):
4,000.0
Supplier:
Walter’s Ready Mix
Mix Number:
W-172FI U
Date:
06/01/2023
Start Time
04:30 AM
End Time
08:15 AM
Testing:
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
1 7.2 06:10 AM Building A
slab
approx.
A-17
45 34.200 137.3 68 1.5 N/A 5.5 6 Max
Observations/Remarks:
I arrived on site around 4:45 AM. Shortly after arriving and parking, I exited my vehicle and began to inspect the
rebar placement, and found it to be within general conformance to project guidelines. Afterwards I began to
setup my testing equipment and wait for the first trucks arrival.
The first truck arrived at 5:00 AM. I grabbed my sample between 5:10-5:15 AM. I concluded all of my tests with
satisfactory results and informed the contractor of the results.
I observed the contractor use all of the correct procedures to make sure the concrete had the right displacement,
as well as the correct level and finish. They used mechanical vibration for the correct displacement of the
material.
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8EE06C7F-445C-445F-80EB-6527F5406064 2
Tested By:
B. Choffin
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
06/01/2023
Inspection Images
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
8EE06C7F-445C-445F-80EB-6527F5406064 3
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
E4259BC3-BE4F-45E2-87A1-3BF020F1E047 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
30.0
Ticket #:
05080
Project Name:
U-Haul Moving and Storage
Test Location:
Building A Gridline C:31
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322, MA AE
90
Required 28 day Strength
(psi):
3,500.0
Supplier:
Walters Ready Mix, Inc.
Mix Number:
142-3500
Date:
06/01/2023
Start Time
04:30 AM
End Time
08:30 AM
Testing:
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
1 30.0 05:55 AM Building A
Gridline C:
31
46 35.700 143.4 68 5.0 N/A 6 8 Max
2 60.0 06:55 AM Building A
Gridline A:
12
(Middle of
A and B)
47 35.520 142.7 65 4.5 N/A 6 8 Max
Observations/Remarks:
I arrived on site at approximately 4:55 AM and proceeded to immediately set up my testing equipment in
preparation for testing.
As soon as my gear was prepared, I acquired a sample from the first truck at approximately 5:20 AM. When
testing this sample the air quality was .5% lower than passing. The truck had already finished pouring by the
time the test was completed. I then tested the third truck at approximately 5:55 AM and found all tests to be
passing within the given parameters. When the sixth truck arrived I tested it and found it also to be passing
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
E4259BC3-BE4F-45E2-87A1-3BF020F1E047 2
within all given parameters.
I then cleaned all of my equipment and gear. I noted that the workers made sure that the concrete was set
correctly well after it was poured. I also noted they used a mechanical vibrating machine to ensure the concrete
was consolidated correctly.
Tested By:
Michael Hammar
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
06/01/2023
Inspection Images
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
E4259BC3-BE4F-45E2-87A1-3BF020F1E047 3
File name:
22247FB06012023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
259A5448-B8B3-4931-9E86-9C247B9E6D9B 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
2.25
Project Name:
U-Haul Moving and Storage
Test Location:
Elevator shaft @ 12
Client:
Bateman-Hall
Admixtures:
N/A
Ticket Number:
4954
Contractor:
JW Masonry
Supplier:
Walters Ready Mix, Inc.
Mix Number:
41
Date:
5/25/2023
Cylinder Log #:
214
Field Test Results:
Set #:
1
Entrained Air
(%):
0.0
Concrete
Temperature
(°F):
73
Ambient
Temperature
(°F):
67
Unit Weight
(PCF):
0
Tested By:
Luke Hammar
Date:
5/25/2023
Picked Up By:
Jense Christensen
Date:
5/26/2023
Time:
9:44 AM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/1/2023 3.390 9.02 39,010.0 4325 3,500.0 Type 3
Date:
06/01/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB06042023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
46B86A57-3174-4179-979F-F02BA32EDCD8 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
30.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building A Gridline C:31
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322, MA
AE 90
Ticket Number:
5080
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix, Inc.
Mix Number:
142-3500
Date:
6/1/2023
Cylinder Log #:
228
Field Test Results:
Set #:
2
Entrained Air
(%):
5.0
Concrete
Temperature
(°F):
68
Ambient
Temperature
(°F):
46
Unit Weight
(PCF):
143.4
Tested By:
Michael Hammar
Date:
6/1/2023
Picked Up By:
Jense Christensen
Date:
6/2/2023
Time:
11:00 AM
Max, Min Temperature
81,59
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 3 6/4/2023 4.000 12.56 45,380.0 3613 3,500.0 Type 1
Date:
06/05/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB06032023JPC
set2
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
C7301A63-F97C-42CB-A908-5E34B07098ED 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
60.0
Project Name:
U-Haul Moving and Storage
Test Location:
Building A Gridline A:12 (Middle of A and B)
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322, MA
AE 90
Ticket Number:
5084
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix, Inc.
Mix Number:
142-3500
Date:
6/1/2023
Cylinder Log #:
229
Field Test Results:
Set #:
3
Entrained Air
(%):
4.5
Concrete
Temperature
(°F):
65
Ambient
Temperature
(°F):
47
Unit Weight
(PCF):
142.7
Tested By:
Michael Hammar
Date:
6/1/2023
Picked Up By:
Jense Christensen
Date:
6/2/2023
Time:
11:23 AM
Max, Min Temperature
81,59
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 3 6/4/2023 4.000 12.56 44,910.0 3576 3,500.0 Type 2
Date:
06/05/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB06082023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
5FF90E52-3F16-47BA-AD59-17ABB9B12875 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
60
Project Name:
U-Haul Moving and Storage
Test Location:
Building A Gridline A:12 (Middle of A and B)
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322, MA
AE 90
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix, Inc.
Mix Number:
142-3500
Date:
6/1/2023
Cylinder Log #:
229
Field Test Results:
Set #:
3
Entrained Air
(%):
4.5
Concrete
Temperature
(°F):
65
Ambient
Temperature
(°F):
47
Unit Weight
(PCF):
142.7
Tested By:
Michael Hammar
Date:
6/1/2023
Picked Up By:
Jense Christensen
Date:
6/2/2023
Time:
11:23 AM
Max, Min Temperature
81,59
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 3 6/4/2023 12.56 44910 3576 3,500.00 Type 2
File name:
22247SB06082023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
5FF90E52-3F16-47BA-AD59-17ABB9B12875 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 7 6/8/2023 4.000 12.56 57,430.0 4572 3,500.0 Type 3
Second Break Average:
4572
Date:
06/08/2023
Reviewed By:
Luke Hammar
Signature:
File Name
22247C06152023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
A8716F72-5906-495F-8021-07FCAE25AA39 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10.0
Ticket #:
22411642
Project Name:
U-Haul Moving and Storage
Test Location:
See photo in reference to pg C6 on the plans
Concrete Member:
Exterior Slab
Client:
Bateman-Hall
Admixtures:
N/A
Required 28 day Strength
(psi):
4,000.0
Contractor
Bryant Greene Construction
Supplier:
Knife River
Mix Number:
IF CL40 BF
Date:
06/15/2023
Start Time
07:45 AM
End Time
09:45 AM
Testing:
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
1 10.0 08:15 AM See photo
in
reference
to pg C6
on the
plans
50 35.160 141.2 64 5.5 6 +-
1.5
4 1/2 8 Max
Observations/Remarks:
I arrived at the job site around 7:45 AM. I looked over the forms and spoke with the foreman about the mix and
the supplier.
I returned to my vehicle and began setting up my equipment. The truck showed up just after 8:00 AM and I was
able to grab the batch ticket. Mike with Knife River showed up shortly after.
I observed as they offloaded some of the mix and was able to grab a sample after they offloaded about a yard.
I returned to my vehicle to begin testing air and slump. Mike observed as I tested and recorded results as I got
File Name
22247C06152023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
A8716F72-5906-495F-8021-07FCAE25AA39 2
them.
The air content as well as the slump results were within general conformance with the jobs parameters. And I
reported said results to Mike as stated earlier.
I then cast strength specimens and I observed the remainder of the pour.
I then returned to my vehicle and began filling out my report.
Tested By:
M.Mansfield
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
06/16/2023
Inspection Images
File Name
22247C06152023MM
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
A8716F72-5906-495F-8021-07FCAE25AA39 3
File Name
22247C06162023MH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
61A5461F-6D5A-4BEF-9D11-24CFB8ABFF95 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10.0
Ticket #:
22411717
Project Name:
U-Haul Moving and Storage
Test Location:
North Valley Gutters
Concrete Member:
Site Elements
Client:
Bateman-Hall
Admixtures:
N/A
Required 28 day Strength
(psi):
3,500.0
Contractor
Bryan Landon Construction
Supplier:
Knife River
Mix Number:
C401G456
Date:
06/16/2023
Start Time
08:40 AM
End Time
09:20 AM
Testing:
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
1 10.0 08:50 AM North
Valley
Gutters
54 35.200 141.4 63 7.0 6 +-
1.5
3.5 8 Max
Observations/Remarks:
I arrived on site at approximately 4:15 AM for a different pour on the same project, so I was already present
with gear set up for this pour.
The truck arrived at approximately 8:40 AM and immediately prepared to pour. Once a sufficient amount had
been poured, I collected a sample for testing.
The tests I performed were in general conformance with project specifications and were reported to the
contractor.
I then cleaned my gear and began this report.
Tested By:Reviewed By:
File Name
22247C06162023MH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
61A5461F-6D5A-4BEF-9D11-24CFB8ABFF95 2
Michael Hammar
Signature:
Luke Hammar
Signature:
Date:
06/16/2023
Inspection Images
File Name
22247C06142023MH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
E6F9B0FA-42BB-4355-A527-673ED015CCE7 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10.0
Ticket #:
22411597
Project Name:
U-Haul Moving and Storage
Test Location:
Valley Gutter, 5 Ft south of building I.
Concrete Member:
Site Elements
Client:
Bateman-Hall
Admixtures:
Required 28 day Strength
(psi):
3,500.0
Contractor
Bryan Landon Construction
Supplier:
Knife River
Mix Number:
C401G456
Date:
06/14/2023
Start Time
10:45 AM
End Time
01:25 PM
Testing:
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
1 10.0 12:00 PM Valley
Gutter, 5
Ft south
of
building I.
65 35.140 141.1 70 6.0 6 +-
1.5
4 8 Max
Observations/Remarks:
I arrived on site at approximately 11:20 AM and set up my equipment in preparation for testing. I then met with
the contractor to inform him I would be testing. The truck arrived at approximately 11:55 AM and immediately
began preparing to pour.
Once a sufficient amount had been poured, I collected my sample for testing. The tests I performed were in
general conformance with project specifications. I then reported the results to the contractor.
I then proceeded to clean my gear and enter my vehicle to begin this report.
Tested By:Reviewed By:
File Name
22247C06142023MH
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
E6F9B0FA-42BB-4355-A527-673ED015CCE7 2
Michael Hammar
Signature:
Luke Hammar
Signature:
Date:
06/16/2023
Inspection Images
File Name
22247C06162023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
BDE2DCE6-5FA4-4977-A639-3FE06009689A 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10.0
Ticket #:
05565
Project Name:
U-Haul Moving and Storage
Test Location:
Building B slab
Concrete Member:
Interior Slab
Client:
Bateman-Hall
Admixtures:
MS AC 534, Delvo, MP 322
Required 28 day Strength
(psi):
4,000.0
Contractor
Bryan Landon Construction
Supplier:
Walter’s Ready Mix, Inc.
Mix Number:
1421 4000
Date:
06/16/2023
Start Time
04:00 AM
End Time
01:15 PM
Testing:
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
1 10.0 04:45 AM Building B
slab
42 35.800 143.8 71 1.5 N/A 6 6 Max
2 70.0 05:05 AM Building B
slab
42 36.180 145.3 67 1.9 N/A 7 6 Max
3 110.0 05:40 AM Building B
slab
43 35.860 144.0 67 1.9 N/A 6.5 6 Max
4 150.0 06:30 AM Building B
slab
45 36.300 145.8 65 1.9 N/A 6.5 6 Max
5 200.0 07:15 AM Building B
slab
48 36.300 145.8 66 1.9 N/A 6 6 Max
6 280.0 08:15 AM Building B
slab
53 36.600 147.0 67 1.5 N/A 6 6 Max
7 320.0 08:50 AM Building B
slab
55 36.400 146.2 68 1.5 N/A 6.5 6 Max
8 370.0 09:00 AM Building B
slab
56 36.080 144.9 69 2.0 N/A 7 6 Max
9 400.0 09:40 AM Building B 59 36.600 147.0 69 1.7 N/A 6.5 6 Max
File Name
22247C06162023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
BDE2DCE6-5FA4-4977-A639-3FE06009689A 2
Set #:Cumulative
Test
Load
Amount:
Time
Tested:
Test
Location:
Ambient
Temp.
(°F):
Weight
of
Concrete
(lbs):
Unit
Weight
(PCF):
Concrete
Temp.
(°F):
Entrained
Air
(%):
Entrained
Air
Spec.
(%):
Slump
(in):
Slump
Spec.
(in):
slab
10 460.0 10:25 AM Building B
slab
61 36.540 146.7 71 1.5 N/A 6.5 6 Max
11 510.0 11:10 AM Building B
slab
63 36.560 146.8 73 2.0 N/A 6 6 Max
12 560.0 12:00 PM Building B
slab
65 36.360 146.0 75 2.0 N/A 6 6 Max
Observations/Remarks:
I arrived on site around 4:20 AM. I exited my truck and began to inspect the rebar placement within Building B
and found it to be within project specifications.
The first truck arrived around 4:40 AM. I sampled and performed a concrete field test. I reported my results to
the contractor. I then took a sample every 50 yards performing a field test with each sample. Strength
specimens were made for each sample that was taken.
I observed the contractor place the concrete.
Tested By:
B. Choffin
Signature:
Reviewed By:
Luke Hammar
Signature:
Date:
06/16/2023
Inspection Images
File Name
22247C06162023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
BDE2DCE6-5FA4-4977-A639-3FE06009689A 3
File Name
22247C06162023BC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
BDE2DCE6-5FA4-4977-A639-3FE06009689A 4
File name:
22247FB06162023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
7A59D876-CEB2-4AB0-A18D-4DB56BA65AA7 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10
Project Name:
U-Haul Moving and Storage
Test Location:
Approx. 300 South of Northwest corner of Building B.
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322
Ticket Number:
5353
Contractor:
Bryan Landon Construction
Supplier:
Walters Ready Mix, Inc.
Mix Number:
W172FI 35
Date:
6/9/2023
Cylinder Log #:
244
Field Test Results:
Set #:
1
Entrained Air
(%):
1.5
Concrete
Temperature
(°F):
70
Ambient
Temperature
(°F):
48
Unit Weight
(PCF):
145.1
Tested By:
B. Choffin
Time Tested:
08:07 AM
Picked Up By:
Jense Christensen
Date:
6/10/2023
Time:
1:00 PM
Max, Min Temperature
80, 60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/16/2023 4.000 12.57 50,615.0 4027 4,000.0 Type 6
Date:
06/16/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB06222023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
63036855-9BA9-486D-8111-912D7636CCB8 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
2.2
Project Name:
U-Haul Moving and Storage
Test Location:
Elevator shaft @ 12
Client:
Bateman-Hall
Admixtures:
N/A
Contractor:
JW Masonry
Supplier:
Walters Ready Mix, Inc.
Mix Number:
41
Date:
5/25/2023
Cylinder Log #:
214
Field Test Results:
Set #:
1
Entrained Air
(%):
0.0
Concrete
Temperature
(°F):
73
Ambient
Temperature
(°F):
67
Unit Weight
(PCF):
0
Tested By:
Luke Hammar
Date:
5/25/2023
Picked Up By:
Jense Christensen
Date:
5/26/2023
Time:
9:44 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/1/2023 9.02 39010 4325 3,500.00 Type 3
File name:
22247SB06222023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
63036855-9BA9-486D-8111-912D7636CCB8 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 6/22/2023 3.450 9.34 50,640.0 5422 3,500.0 Type 3
C 28 6/22/2023 3.410 9.13 49,155.0 5384 3,500.0 Type 6
D 28 6/22/2023 3.430 9.24 48,120.0 5208 3,500.0 Type 3
Second Break Average:
5338
Date:
06/22/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB06222023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
643561AF-01E1-45BE-A29E-D4C1A0FA91CA 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10
Project Name:
U-Haul Moving and Storage
Test Location:
Valley gutter, 5 ft. south of building 1.
Client:
Bateman-Hall
Admixtures:
AE200, POLY980
Ticket Number:
22411597
Contractor:
Bryan Landon Construction
Supplier:
Knife River
Mix Number:
C401G456
Date:
6/14/2023
Cylinder Log #:
276
Field Test Results:
Set #:
1
Entrained Air
(%):
6.0
Concrete
Temperature
(°F):
70
Ambient
Temperature
(°F):
65
Unit Weight
(PCF):
141.1
Tested By:
Michael Hammar
Time Tested:
08:10 AM
Picked Up By:
Jense Christensen
Date:
6/15/2023
Time:
1:38 PM
Max, Min Temperature
80,60
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/21/2023 4.000 12.57 44,360.0 3529 3,500.0 Type 6
Date:
06/22/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB06232023JPC13
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
3DC127AE-782F-4A07-8B42-D58B8DB2265E 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
560
Project Name:
U-Haul Moving and Storage
Test Location:
Building B slab
Client:
Bateman-Hall
Admixtures:
MS AC 534, Delvo, MP 322
Ticket Number:
5623
Contractor:
Bryan Landon Construction
Supplier:
Walters Ready Mix, Inc.
Mix Number:
1421 4000
Date:
6/16/2023
Cylinder Log #:
275
Field Test Results:
Set #:
13
Entrained Air
(%):
2.0
Concrete
Temperature
(°F):
75
Ambient
Temperature
(°F):
65
Unit Weight
(PCF):
146
Tested By:
B. Choffin
Time Tested:
09:59 AM
Picked Up By:
Jense Christensen
Date:
6/17/2023
Time:
1:30 PM
Max, Min Temperature
80,62
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/23/2023 4.000 12.57 62,835.0 4999 4,000.0 Type 3
Date:
06/23/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247FB06232023JPC12
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
7E1E6BC9-C65D-4FDE-877F-E865BEA804B4 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
510
Project Name:
U-Haul Moving and Storage
Test Location:
Building B slab
Client:
Bateman-Hall
Admixtures:
MS AC 534, Delvo, MP 322
Ticket Number:
5618
Contractor:
Bryan Landon Construction
Supplier:
Walters Ready Mix, Inc.
Mix Number:
1421 4000
Date:
6/16/2023
Cylinder Log #:
274
Field Test Results:
Set #:
12
Entrained Air
(%):
2.0
Concrete
Temperature
(°F):
73
Ambient
Temperature
(°F):
63
Unit Weight
(PCF):
146.8
Tested By:
B. Choffin
Time Tested:
09:56 AM
Picked Up By:
Jense Christensen
Date:
6/17/2023
Time:
1:30 PM
Max, Min Temperature
80,62
Initial Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/23/2023 4.000 12.57 61,135.0 4864 4,000.0 Type 1
Date:
06/23/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB06282023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
00990AAE-1114-4CFF-9FB4-E7C3C6685A7B 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
10
Project Name:
U-Haul Moving and Storage
Test Location:
Building A Gridline E:9
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322, MA
AE 90
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix, Inc.
Mix Number:
142-3500
Date:
5/31/2023
Cylinder Log #:
222
Field Test Results:
Set #:
1
Entrained Air
(%):
5.0
Concrete
Temperature
(°F):
69
Ambient
Temperature
(°F):
46
Unit Weight
(PCF):
141
Tested By:
M. Hammar
Date:
5/31/2023
Picked Up By:
Jense Christensen
Date:
6/1/2023
Time:
9:00 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/7/2023 12.57 54315 4321 3,500.00 Type 2
File name:
22247SB06282023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
00990AAE-1114-4CFF-9FB4-E7C3C6685A7B 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 6/28/2023 4.000 12.57 66,110.0 5259 3,500.0 Type 3
C 28 6/28/2023 4.000 12.57 66,400.0 5282 3,500.0 Type 1
D 28 6/28/2023 4.000 12.57 66,705.0 5307 3,500.0 Type 2
Second Break Average:
5283
Date:
06/28/2023
Reviewed By:
Luke Hammar
Signature:
File name:
22247SB06282023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
5C362763-2F5A-4093-BAF1-3B7DB799A3CB 1
4103 E 605 N Suite 1
Rigby, ID 83442
208.932.4428
Compressive Strength of Concrete Test Specimens
Project Number:
22-247
Cumulative Test Load Amount:
60
Project Name:
U-Haul Moving and Storage
Test Location:
Building A Gridline D:14
Client:
Bateman-Hall
Admixtures:
MS AC 534, MP 322, MA
AE 90
Contractor:
Bryan Landon
Supplier:
Walters Ready Mix, Inc.
Mix Number:
142-3500
Date:
5/31/2023
Cylinder Log #:
223
Field Test Results:
Set #:
2
Entrained Air
(%):
5.0
Concrete
Temperature
(°F):
68
Ambient
Temperature
(°F):
50
Unit Weight
(PCF):
141.4
Tested By:
M. Hammar
Date:
5/31/2023
Picked Up By:
Jense Christensen
Date:
6/1/2023
Time:
9:00 AM
Max, Min Temperature
80, 60
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 6/7/2023 12.57 51105 4066 3,500.00 Type 1
File name:
22247SB06282023JPC
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
5C362763-2F5A-4093-BAF1-3B7DB799A3CB 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 6/28/2023 4.000 12.57 61,175.0 4867 3,500.0 Type 1
C 28 6/28/2023 4.000 12.57 62,765.0 4993 3,500.0 Type 3
D 28 6/28/2023 4.000 12.57 61,785.0 4915 3,500.0 Type 3
Second Break Average:
4925
Date:
06/28/2023
Reviewed By:
Luke Hammar
Signature: