HomeMy WebLinkAboutPLANS - 23-00397 - BYU-I - Benson Fascia Remodel - MechanicalA201 C1 A A 1 1 2 2 3 3 4 4 5 5 6 6 7 7 B B C C D D E E F F G G H H J J K K L L M M N N 90 ' - 4 " 22 ' - 6 " 22 ' - 6 " 22 ' - 6 " 22 ' - 1 0 " A2 A103 ________________ A4 A103 ________________ A1 A103 ________________ A3 A103 ________________ TYP TYP THIS WALL ONLY THIS WALL ONLY 417' - 8 11/32" 26' - 4"30' - 0"30' - 0"30' - 0"30' - 0"17' - 5"41' - 4"29' - 10 1/4"18' - 5 3/4"29' - 10"4' - 0 1/4"55' - 4"27' - 0 9/32"48' - 0 13/16" A201 C4 A201 E1 NEW ALUMINUM CLAD SOFFIT VENTILATION TO BE PER MANUFACTURER'S RECOMMENDATION AND NEEDS TO COORDINATE WITH OPENINGS IN THE PLYWOOD. OR ADDITIONAL OPENINGS TO BE PROVIDED IN THE PLYWOOD. NEW ALUMINUM CLAD SOFFIT VENTILATION TO BE PER MANUFACTURER'S RECOMMENDATION AND NEEDS TO COORDINATE WITH OPENINGS IN THE PLYWOOD. OR ADDITIONAL OPENINGS TO BE PROVIDED IN THE PLYWOOD. IT IS OUR UNDERSTANDING THAT THIS SCREENED VENT NO LONGER EXISTS. PUNCHED OPENINGS / MECHANICAL DIFUSERS ARE CURRENTLY THROUGHOUT WRAP ACM TO CONCEAL UNDERSIDE CONNECTION CONT. PREFINISHED FLASHING ACM PANEL SYSTEM WITH EXTRUSION CLIPS. 4'-0" TALL (F.V.) X 10'-0" WIDE. FEILD VERIFY EXISTING HEIGHT . EXISTING SHEATHING TO REMAIN UNLESS DAMAGED. REPLACE TO MATCH EXISTING IF DAMAGED. NEW MOISTURE BARRIER OVER SHEATHING NEW ALUMINUM PANEL SOFFIT. COLOR TO MATCH NEW SIDING NEW ALUMINUM COPING EVE TRIM WITH BULNOSE NEW STANDING SEAM OPTION 3 -NEW ALUMINUM PANEL. HOLCIM, PROFILE UC-500, 12" WIDE FLAT (NO RIBS OR STRIATIONS), .032" ALUMINUM, COLOR SILVER METTALIC KYNAR. COLOR TO BE VERIFIED BY ARCHITECT PRIOR TO PURCHASE. WRAP ACM TO CONCEAL UNDERSIDE CONNECTION CONT. PREFINISHED FLASHING ACM PANEL SYSTEM WITH EXTRUSION CLIPS. 4'-0" TALL (F.V.) X 10'-0" WIDE. FEILD VERIFY EXISTING HEIGHT . EXISTING SHEATHING TO REMAIN UNLESS DAMAGED. REPLACE TO MATCH EXISTING IF DAMAGED. NEW MOISTURE BARRIER OVER SHEATHING NEW DRIP EDGE NEW ROOFING MEMBRANE, BY OTHERS, OVER THE NEW DRIP EDGE OPTION 3 -NEW ALUMINUM PANEL. HOLCIM, PROFILE UC-500, 12" WIDE FLAT (NO RIBS OR STRIATIONS), .032" ALUMINUM, COLOR SILVER METTALIC KYNAR. COLOR TO BE VERIFIED BY ARCHITECT PRIOR TO PURCHASE. EXISTING ROOF PLAN AND RCP LEGEND INDICATES FASCIA AND SOFFIT WITHIN THE SCOPE OF WORK THAT NEEDS TO BE REMOVED AND REPLACED. RE: DETAILS FOR RECOMMENDED NEW MATERIAL OPTIONS. INDICATES FASCIA THAT APPEARS TO BE IN GOOD SHAPE AND SIMILAR COLOR TO THE EAST WING. THIS AREA HAS LOW VISIBILITY. IT IS RECOMMENDED TO LEAVE THIS FASCIA UNTOUCHED AND WOULD BE OUT OF SCOPE. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 12557 4/25/2023 A103 ROOF PLANS 23.0015 4/25/2023 525 S CENTER ST REXBURG, ID 83460 Benson Fascia Remodel BID SET GENERAL FASCIA SUGGESTIONS 1 PER OWNER'S REQUEST, THESE ARE RECOMMENDATIONS AND LOCATIONS FOR POSSIBLE NEW FASCIA AND SOFFIT MATERIALS. 2 THERE ARE A FEW MECHANICAL GRILLES THAT NEED TO BE REPLACED. IT IS OUR UNDERSTANDING THAT ALL OTHER EXISTING SOFFIT DIFFUSERS ARE FOR THE PURPOSE OF VENTILATING THE SOFFIT. THE EXISTING SOFFIT LIGHTS ALSO NEED TO BE REPLACED. SEE RCP'S FOR NEW RECOMMENDATIONS. 3 IT IS RECOMMENDED THAT THE COLOR OF THE NEW MATERIAL WILL BE A PREFINISHED COLOR AND TO BE SELECTED FROM PHYSICAL SAMPLES PRIOR TO PURCHASING THE PRODUCT. THE RECOMMENDED COLOR IS TO MATCH AS CLOSE AS POSSIBLE THE EAST WING STUCCO GREY FINISH. 4 NOTE THAT THE DETAILS ARE COPIES OF THE ORIGINAL DRAWINGS. OPTION ONE IS SHOWING THE SAME OPTION THAT CURRENTLY EXISTS, AND OPTION TWO HAS SOME MODIFICATIONS FOR ACM PANEL AND ALUMINUM PANEL SOFFIT. 5 BOTH OPTIONS WILL REQUIRE THE REMOVAL OF THE EXISTING FINISH MATERIAL BEFORE APPLYING THE NEW MATERAIL. COORDINATE WITH ROOFING MEMBRANE. 1/16" = 1'-0"B1 Roof Plan 1/2" = 1'-0"A1 FASCIA DETAIL OPTION 1 (A) 1/2" = 1'-0"A2 FASCIA DETAIL OPTION 1(B) 1/2" = 1'-0"A3 FASCIA DETAIL OPTION 2 (A) 1/2" = 1'-0"A4 FASCIA DETAIL OPTION 2(B) ORIGINAL DETAILS (REPLACE WITH SAME MATERIALS)ORIGINAL DETAILS W/ ACM PANEL NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE VIEW THESE DRAWINGS IN COLOR, NOT B&W EXISTING ROOF PLAN AND RCP LEGEND INDICATES FASCIA AND SOFFIT WITHIN THE SCOPE OF WORK THAT NEEDS TO BE REMOVED AND REPLACED. RE: DETAILS FOR RECOMMENDED NEW MATERIAL OPTIONS. INDICATES FASCIA THAT APPEARS TO BE IN GOOD SHAPE AND SIMILAR COLOR TO THE EAST WING. THIS AREA HAS LOW VISIBILITY. IT IS RECOMMENDED TO LEAVE THIS FASCIA UNTOUCHED AND WOULD BE OUT OF SCOPE. A201 C1 A A 1 1 2 2 3 3 4 4 5 5 6 6 7 7 B B C C D D E E F F G G H H J J K K L L M M N N 90 ' - 4 " 22 ' - 6 " 22 ' - 6 " 22 ' - 6 " 22 ' - 1 0 " A2 A103 ________________ A4 A103 ________________ A1 A103 ________________ A3 A103 ________________ TYP TYP THIS WALL ONLY THIS WALL ONLY 417' - 8 11/32" 26' - 4"30' - 0"30' - 0"30' - 0"30' - 0"17' - 5"41' - 4"29' - 10 1/4"18' - 5 3/4"29' - 10"4' - 0 1/4"55' - 4"27' - 0 9/32"48' - 0 13/16" DISCONNECT AND REMOVE EXISTING RECESSED CAN AND MAINTAIN CIRCUIT FOR NEW LIGHT. PROVIDE AND INSTALL NEW LIGHT FIXTURE SYLVANIA LED/RT8/2000/840 LED DOWN LIGHT. CONNECT TO EXISTING LIGHTING CIRCUIT AND CONTROLS A201 C4 A201 E1 REPLACE EXISTING SOFFIT GRILLES WITH NEW 8"X8" NECK GRILLE. CONNECT NEW GRILLE TO EXISTING DUCTOWORK. COLOR TO MATCH NEW SOFFIT COLOR. GRILLE SHALL BE KRUEGER S585, 1/2" SPACING WITH 35-DEGREE DEFLECTION BLADES, OR EQUAL BY TITUS. IT IS OUR UNDERSTANDING THAT THESE GRILLES ARE EXHUAST GRILLES AND THE OTHERS ARE FOR VENT SOFFIT. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 12557 4/25/2023 A131 RCP PLAN 23.0015 4/25/2023 525 S CENTER ST REXBURG, ID 83460 Benson Fascia Remodel BID SET GENERAL FASCIA SUGGESTIONS 1 PER OWNER'S REQUEST, THESE ARE RECOMMENDATIONS AND LOCATIONS FOR POSSIBLE NEW FASCIA AND SOFFIT MATERIALS. 2 THERE ARE A FEW MECHANICAL GRILLES THAT NEED TO BE REPLACED. IT IS OUR UNDERSTANDING THAT ALL OTHER EXISTING SOFFIT DIFFUSERS ARE FOR THE PURPOSE OF VENTILATING THE SOFFIT. THE EXISTING SOFFIT LIGHTS ALSO NEED TO BE REPLACED. SEE RCP'S FOR NEW RECOMMENDATIONS. 3 IT IS RECOMMENDED THAT THE COLOR OF THE NEW MATERIAL WILL BE A PREFINISHED COLOR AND TO BE SELECTED FROM PHYSICAL SAMPLES PRIOR TO PURCHASING THE PRODUCT. THE RECOMMENDED COLOR IS TO MATCH AS CLOSE AS POSSIBLE THE EAST WING STUCCO GREY FINISH. 4 NOTE THAT THE DETAILS ARE COPIES OF THE ORIGINAL DRAWINGS. OPTION ONE IS SHOWING THE SAME OPTION THAT CURRENTLY EXISTS, AND OPTION TWO HAS SOME MODIFICATIONS FOR ACM PANEL AND ALUMINUM PANEL SOFFIT. 5 BOTH OPTIONS WILL REQUIRE THE REMOVAL OF THE EXISTING FINISH MATERIAL BEFORE APPLYING THE NEW MATERAIL. COORDINATE WITH ROOFING MEMBRANE. 1/16" = 1'-0"B1 REFLECTED CEILING PLAN EXISTING FASCIA PHOTOS BETWEEN EAST AND WEST WING WEST ENTRANCE OF WEST WING WEST FASCIA AND SOFFIT AT WEST WING NORTH SIDE ENTRANCE SOFFIT SOUTH EAST CORNER OF WEST WING EAST SIDE OF WEST WING VIEW THESE DRAWINGS IN COLOR, NOT B&W A B C D E 1ST LEVEL FINISH FLOOR 86' - 0" T.O. BRICK II 116' - 0" MAIN LEVEL FINISH FLOOR 100' - 0" T.O.P. 1 120' - 8" A1 A103 ________________ A3 A103 ________________TYP TYP EXISTING ROOF PLAN AND RCP LEGEND INDICATES FASCIA AND SOFFIT WITHIN THE SCOPE OF WORK THAT NEEDS TO BE REMOVED AND REPLACED. RE: DETAILS FOR RECOMMENDED NEW MATERIAL OPTIONS. INDICATES FASCIA THAT APPEARS TO BE IN GOOD SHAPE AND SIMILAR COLOR TO THE EAST WING. THIS AREA HAS LOW VISIBILITY. IT IS RECOMMENDED TO LEAVE THIS FASCIA UNTOUCHED AND WOULD BE OUT OF SCOPE. 1234567 MAIN LEVEL FINISH FLOOR 100' - 0" T.O. SKYBRIDGE 114' - 0" T.O.P. 1 120' - 8" MECH. BASEMENT FIN. FLR. 89' - 6" F A1 A103 ________________ A3 A103 ________________TYP TYP 1 2 3 4 5 6 7 MAIN LEVEL FINISH FLOOR 100' - 0" T.O.P. 1 120' - 8" T.O. MASONRY 115' - 4" BASEMENT 1 87' - 2" F G H J K L M N A1 A103 ________________ A3 A103 ________________TYP TYP A2 A103 ________________ A4 A103 ________________THIS WALL ONLY THIS WALL ONLY 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : d a t e : UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 b y u i d a h o p r o j e c t # : 12557 4/25/2023 A201 EXTERIOR ELEVATIONS 23.0015 4/25/2023 525 S CENTER ST REXBURG, ID 83460 Benson Fascia Remodel BID SET 1/16" = 1'-0"C1 ELEVATION EXTERIOR 1 GENERAL FASCIA SUGGESTIONS 1 PER OWNER'S REQUEST, THESE ARE RECOMMENDATIONS AND LOCATIONS FOR POSSIBLE NEW FASCIA AND SOFFIT MATERIALS. 2 THERE ARE A FEW MECHANICAL GRILLES THAT NEED TO BE REPLACED. IT IS OUR UNDERSTANDING THAT ALL OTHER EXISTING SOFFIT DIFFUSERS ARE FOR THE PURPOSE OF VENTILATING THE SOFFIT. THE EXISTING SOFFIT LIGHTS ALSO NEED TO BE REPLACED. SEE RCP'S FOR NEW RECOMMENDATIONS. 3 IT IS RECOMMENDED THAT THE COLOR OF THE NEW MATERIAL WILL BE A PREFINISHED COLOR AND TO BE SELECTED FROM PHYSICAL SAMPLES PRIOR TO PURCHASING THE PRODUCT. THE RECOMMENDED COLOR IS TO MATCH AS CLOSE AS POSSIBLE THE EAST WING STUCCO GREY FINISH. 4 NOTE THAT THE DETAILS ARE COPIES OF THE ORIGINAL DRAWINGS. OPTION ONE IS SHOWING THE SAME OPTION THAT CURRENTLY EXISTS, AND OPTION TWO HAS SOME MODIFICATIONS FOR ACM PANEL AND ALUMINUM PANEL SOFFIT. 5 BOTH OPTIONS WILL REQUIRE THE REMOVAL OF THE EXISTING FINISH MATERIAL BEFORE APPLYING THE NEW MATERAIL. COORDINATE WITH ROOFING MEMBRANE. 1/16" = 1'-0"C4 Elevation 1 - a 1/16" = 1'-0"E1 Elevation 2 - a NOTE: NOT ALL FACES OF WALLS AND FASCIA ARE ELEVATED. THE OVERALL EXTERIOR ELEVATIONS ARE SHOWN FOR DESIGN INTENT. THE VERITICAL LINES INDICATE WHERE THE POSSIBLE LOCATION OF THE ACM JOINTS OR THE VERTICAL BOARD AND BATTEN WOULD BE.VIEW THESE DRAWINGS IN COLOR, NOT B&W