HomeMy WebLinkAboutSOILS REPORT - 23-00046 - 240 E Moody - Wendy's - New Building 3Test Information
Test #Test Location Elevation Reference
Gauge
Make / Model / SN / Calibrated Field Technician
3 Structural Fill: Exterior Slab-on-Grade: Southwest corner of building: ¶South, ¶
East.
4.0 Inches below finish grade Troxler / 3440 / 18792 / 02/07/2023 Franson, John
4 Structural Fill: Exterior Slab-on-Grade: Southwest corner of building: ¶South, ¶
East.
4.0 Inches below finish grade Troxler / 3440 / 18792 / 02/07/2023 Franson, John
5 Structural Fill: Exterior Slab-on-Grade: Northeast corner of building: ¶North, ¶
West.
4.0 Inches below finish grade Troxler / 3440 / 18792 / 02/07/2023 Franson, John
6 Structural Fill: Exterior Slab-on-Grade: Northeast corner of building: ¶North, ¶
East.
4.0 Inches below finish grade Troxler / 3440 / 18792 / 02/07/2023 Franson, John
Remarks
DP: Density Pass
Comments
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
3, 4, 5, 6: The Atlas Rep (John Franson) informed Construction
Solutions superintendent (Josh) of test results. Report was emailed to
all approved recipients.
Test Results
Test #
Retest
Of Test Date Proctor ID Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry
Density (pcf)
In Place
Moisture
(%)
In Place
Dry
Density
(pcf)
In Place
Wet
Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
(%)Remark
3 06/07/23 23-7108 C Pit Run 8.0 134.6 4.4 128.3 134.0 2 95 95 DP
4 06/07/23 23-7108 C Pit Run 8.0 134.6 5.3 131.1 138.0 2 97 95 DP
5 06/07/23 23-7108 C Pit Run 8.0 134.6 6.3 128.3 136.4 6 95 95 DP
6 06/07/23 23-7108 C Pit Run 8.0 134.6 3.8 130.3 135.2 6 97 95 DP
This report shall not be reproduced, in full, without the prior written approval of Atlas Technical Consultants, LLC. Results only relate to the items inspected or
tested. Please note the sampling plan. Results only apply to materials tested as listed in the report.
Page 1 of 1
Soil Nuclear Gauge
Test Method: ASTM D 6938
Report Date: 06/07/2023
Report #: -00
Client:
Classic Foods, Inc.
Idaho Falls, ID 83402
1585 N. Skyline Drive
Project:
Wendy's - Rexburg, Moody Rd & N. 2nd E.,
Rexburg, ID
E230566l
Rexburg, ID 83440
240 E Moody Road
43.854507, -111.776561
1753 E Precision Drive
Idaho Falls, ID 83402
Phone: (208) 529-8242
Atlas Technical Consultants, LLC - Idaho Falls