HomeMy WebLinkAboutREVISED PLAN - 22-00588 - Cedar Point Trucking - New Commercial Bldg156' - 0"
10
0
'
-
0
"
3' - 0"2' - 0"16' - 0"6' - 0"16' - 0"13' - 0"16' - 0"6' - 0"16' - 0"1' - 0"3' - 0"
3' - 0"2' - 0"16' - 0"6' - 0"16' - 0"13' - 0"16' - 0"6' - 0"16' - 0"2' - 2"3' - 0"
26' - 0"26' - 0"26' - 0"26' - 0"26' - 0"26' - 0"
0'
-
6
"
24
'
-
6
"
25
'
-
0
"
25
'
-
0
"
24
'
-
6
"
0'
-
6
"
1234 5 6 7
A
B
C
D
E
25
'
-
0
"
25
'
-
0
"
7'
-
6
"
www.titansteelidaho.com
Scale
Date
Drawn By
Checked By
Project Number
TITAN STEEL LLC
P.O. BOX 326
Rigby, ID 83442
(208) 709-7553
Layne Walker
(208) 351-8677
Steve Wilcox
(208) 709-7553
Kent Smith
(208) 512-4159
COPYRIGHT 2020 by TITAN STEEL
All rights reserved. Reproduction or translation of any part of
this work without written permission is unawfull. Violaters will
be prosecuted.
1" 6'-0"
6/
2
0
/
2
0
2
2
4
:
4
8
:
5
2
P
M
A01
FLOOR PLAN
CEDARPOINT TRUCKING
RKS
AR
05/17/2022
Project Number
No.Description Date
1" 6'-0"1FLOOR PLAN
12' X 14'
SHOP
OFFICE20' X 50'
PARS AREA
50' X 50'
LOUNGE
AREA
1/2 LOAD
MAIN
FRAME
T.O. WALL
ELEV 102' - 0"
T.O. PIER
ELEV 100' - 0"
T.O. PIER
ELEV 100' - 0"
T.O. PIER
ELEV 100' - 0"
1/2 LOAD
MAIN FRAME
T.O. WALL
ELEV 102' - 0"
ENDWALL COL
@ ELEV 102' - 0"
(TYP U.N.O.)
FULL HGT LINER PANEL
AT SHOP AREA - MATCH
EXTERIOR COLORSBASE OF COLUMN
@ ELEV 100' - 0"
BASE OF COLUMN
@ ELEV 100' - 0"
OVERHEAD DOOR
16' X 14'
OVERHEAD DOOR
16' X 14'
OVERHEAD DOOR
16' X 14'
(WASH BAY)
OVERHEAD DOOR
16' X 14'
(WASH BAY)
OVERHEAD DOOR
16' X 14'
(CAR WASH)
OVERHEAD DOOR
16' X 14'
(CAR WASH)
OVERHEAD DOOR
16' X 14'
OVERHEAD DOOR
16' X 14'
"PBR" LINER PANEL
FROM T.O. STEMWALL TO
EAVE @ SHOP AREA -
LINER COLORS TO
MATCH EXTERIOR
OPTIONAL
ARCHITECTURAL
BUILDING BUMP OUT
29' X 4'
52' X 100'
SHOP AREA
FULL CEILING
LINER @
WASH BAY AND
T.O. STEMWALL
ELEV 102' - 0"
T.O. WALL PIER
ELEV 102' - 0"
T.O. WALL PIER
ELEV 102' - 0"
T.O. WALL PIER
ELEV 102' - 0"
3/4" T&G
PLYWOOD FROM
T.O. STEMWALL
TO 10' - 0" AFF
METAL PANEL
ABOVE PLYWOOD
ENDWALL COL
& T.O. WALL
ELEV 102' - 0"
(TYPICAL U.N.O)
50LF
CONCRETE
FLOOR DRAINS
(TYP)
ENDWALL COL
& T.O. WALL
ELEV 102' - 0"
(TYPICAL U.N.O)
ENDWALL COL
& T.O. WALL
ELEV 102' - 0"
(TYPICAL U.N.O)
T.O. PIER
ELEV 100' - 0"
T.O.PIER
ELEV 100' - 0"
T.O. PIER
ELEV 100' - 0"
L HGT
L LINER
"X" BRACE
FULL HGT
LINER PANEL
OVERHEAD DOOR
8" X 10'
15' X 50'
EQUIPMENT
ROOM
T.O.W.
ELEV 102' - 0"
FULL HGT
WALL & CEILING
LINER
BASE OF COLUMN
@ ELEV 100' - 0"
FULL HGT
LINER
VI 05/26/2022
VII 05/27/2022
VIII 06/07/2022
10' X 7' 2" OPENING
CENTER
BETWEEN COLUMNS
IX 06/20/2022
NOTES:
- CONNECT 4 WET BAY DRAINS TO GREASE INTERCEPTOR THEN TO
STORM RETENTION SWALE ALONG THE ROAD.
- BOTH BAYS CLOSER TO THE OFFICES WILL BE "WET" MAINTENANCE.
ALL DRAINS WILL CONNECT TO SAND OIL INTERCEPTOR AND THEN FLOW
INTO STORM AWALE AT ROAD.
SLOPE FLOOR
TO OVERHEAD
DOOR